Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED PLANS - 21-00021 - 106 Birch Ave - Solar Panels
Author Name Author Email Author Phone No.: Bret Stoddard brets@rexburg.org 208-372-2171 Description : 106 Birch Ave - Solar Panels Address : 106 Birch Ave Record Type : Solar Panels Document Filename : LAFOLLETTE PERMIT PACK.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00021 Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT PROJECT INFORMATION, VICINITY MAP www.bigdogenergy.com P V - 1 12/8/2020 ALL CONDUIT TO RUN ON EXTERIOROF HOUSE UNLESS OTHERWISE NOTEDOCCUPANCY:R-3CONSTRUCTION TYPE:VBUNSPRINKLEREDALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH THECODE AND THE MANUFACTURES INSTALLATION INSTRUCTIONS.ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THE PLACARD.LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC2017 CODE. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED. ALL PLUMBING ANDMECHANICAL ROOF VENTS TO CLEAR FROM PHOTOVOLTAICARRAY, OR EXTEND ABOVE SOLAR PANELS. SOLARPHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIALSTRUCTURE. DESIGN COMPLYING WITH THE IBC 2015 CODEAND ALL LOCAL ORDINANCES AND POLICIES. THE PROJECT HASBEEN DESIGNED TO WITHSTAND A MINIMUM 110 MPH WINDLOAD. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITY ISOBTAINED. IF THE MAIN SERVICE PANEL DOES NOT HAVEVERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE. EACH MODULE WILL BE GROUNDED USING THESUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULEAND THE MANUFACTURERS INSTALLATION INSTRUCTIONS. ALADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCEWITH OSHA REGULATIONS. PROPER ACCESS AND WORKINGCLEARANCE WILL BE PROVIDED "WARNING: PV POWERSOURCE" TO BE PLACED EVERY 10 FT.GFCI PROTECTION IN INVERTER.MSPSUBACDCSLCMINVJBCBFMC M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X F L E X I B L E M E T A L L I C C O N D U I T ( E ) ( N ) E X T I N T E M T R M T V O C V M P I S C N T S E X I S T I N G N E W E X T E R I O R I N T E R I O R E L E C T R I C A L M E T A L L I C T U B I N G R I G I D M E T A L L I C T U B I N G V O L T A G E O P E N C I R C U I T V O L T A G E A T M A X . P O W E R S H O R T C I R C U I T C U R R E N T N O T T O S C A L E I M P C U R R E N T A T M A X . P O W E R A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C 2 0 1 5 C O D E P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E ADDITIONAL NOTES P L A N S E T L E G E N D A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N V I C I N I T Y M A P A P P L I C A B L E C O D E S S H E E T I N D E X 1 8 X 3 1 5 W J I N K O P H O T O V O L T A I C M O D U L E S 1 X 7 . 6 K W S O L A R E D G E S Y S T E M S I Z E : 5 , 6 7 0 W D C S T C A R R A Y A R E A : 3 0 6 S F K A T H E Y L A F O L L E T T E 1 0 6 B I R C H A V E R E X B U R G , I D 8 3 4 4 0 2 0 8 - 2 0 6 - 9 6 6 6 KATHEY LAFOLLETTE 106 BIRCH AVE REXBURG, ID 83440 208-206-9666 Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ N MTRACINV MSP METER WITHIN3' OF DISCONNECT CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SITE PLAN, AERIAL VIEW www.bigdogenergy.com P V - 2 SITE PLAN A E R I A L V I E W S C A L E : N T S S C A L E : 1 " = 3 0 ' - 0 " TOTAL # OF PANELS18 A B B R E V I A T I O N S I N V M S P A C I N V E R T E R M A I N S E R V I C E P A N E L A C D I S C O N N E C T M T R M E T E R Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 12/8/2020 KATHEY LAFOLLETTE 106 BIRCH AVE REXBURG, ID 83440 208-206-9666 ROOF TYPE:METAL 5,670W TOTAL SOLAR ARRAY18 JINKO 315W PANELSARRAY 11 STRING OF 18 MODULES CONNECTED IN SERIES @ INVERTERNNGD200ACNGNNGL1L133L2L2_~B 2 1 8 M O D U L E S I N S E R I E S E MPP T 2 S T R I N G 1 T I L T : 2 8 ° A Z I M U T H : 2 7 0 ° / 9 0 ° O N E P E R P A N E L A ELECTRIC A L E Q U I P M E N T C A L L O U T S SOLADE C K M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/RO O F P E N E T R A T I O N , 6 0 0 V 7.6kW IN V E R T E R U N G R O U N D E D SOLARE D G E S E 7 6 0 0 H - U S (240V) IN V E R T E R 240VAC, 3 2 A , N E M A 3 R , U L L I S T E D , (W/ INTE G R A T E D D C D I S C O N N E C T ) WITH IN T E G R A T E D G F P , W / I N T E G R A T E D A F P SQUARE D S A F E T Y S W I T C H , # H 2 2 2 N R B P/N 3112 6 0 0 V D C , 6 0 A , N E M A 3 R , F U S I B L E , 10,000 AI C , U L , N E M A , C S A , N O M C E R T I F I E D W/40A F U S E S 200A MAI N S E R V I C E P A N E L (W/ BIDI R E C T I O N A L U T I L I T Y M E T E R ) SOLARE D G E O P T I M I Z E R P 3 2 0 O N E P E R P A N E L BD A123WIRE AND CONDUIT CALLOUTS(2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT/FMC(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT CE 1 M O D U L E : J I N K O 3 1 5 W V o c = 4 0 . 7 V I s c = 1 0 . 0 4 A V m p = 3 3 . 2 V I m p = 9 . 4 9 A A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . MPP T 1 MPP T 3 40A26.WITHIN 3'ELECTRICAL SINGLE LINE DIAGRAM CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SINGLE LINE DIAGRAM www.bigdogenergy.com P V - 3 S C A L E : N T S E L E C T R I C A L N O T E S R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 2020-12-8 KATHEY LAFOLLETTE 106 BIRCH AVE REXBURG, ID 83440 208-206-9666 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT REQUIRED SIGNAGE www.bigdogenergy.com P V - 4 REQUIRED SIGNAGE1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 14"HIGH LETTERING PER NEC 690-17.2. LABEL FOR SOLAR AC DISCONNECT:FIRE DEPARTMENT REQUIRED SIGNAGE3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 38" HIGHLETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS,WHITE ON RED BACKGROUND AND A REFLECTIVE, WEATHERRESISTANT MATERIAL.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING:WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALS ONBOTH THE LINE AND LOAD SIDES MAY BEENERGIZED IN THE OPEN POSITION."SOLAR AC DISCONNECT" 6 . R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : 7 . A T S E R V I C E D I S C O N N E C T : P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N R A P I D S H U T D O W N D I S C O N N E C T 12/8/2020 KATHEY LAFOLLETTE 106 BIRCH AVE REXBURG, ID 83440 208-206-9666 Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLAR ELECTRIC SYSTEMTHE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THEMAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICEPANEL CLOSED.4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY ACDISCONNECT:CUSTOMER OWNEDONSITE POWER GENERATIONSYSTEM DISCONNECT5. LABEL INSTALLATION AT INTERCONNECT BREAKER:WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years 1 5 10 15 20 25 Gu a r a n t e e d p o w e r p e r f o r m a n c e 97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature: JKM330M - 60HBL Code Cell Code Backsheet Code Cell null Full null White null Normal H Half B Black L Diamond ENGINEERING DRAWINGS PACKAGING CONFIGURATION TEMPERATURE CHARACTERISTICS MAXIMUM RATINGS MECHANICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS Cells Mono PERC Diamond Cell (158.75x158.75mm) No. of Half Cells 120 (6×20) Dimensions 1684×1002×35mm (66.30×39.45×1.38in) Weight 19.0kg (41.9lbs) Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass Frame Anodized Aluminum Alloy Junction Box IP67 Rated Output Cables 12 AWG, 1825mm (71.85in) or Customized Length Fire Type Type 1 Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) (Two pallets = One stack) 31pcs/pallet, 62pcs/stack, 806pcs/40’HQ Container Temperature Coefficients of Pmax -0.36%/°C Temperature Coefficients of Voc -0.28%/°C Temperature Coefficients of Isc 0.048%/°C Nominal Operating Cell Temperature (NOCT)45±2°C Operating Temperature (°C)-40°C~+85°C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 20A Module Type JKM310M-60HBL JKM315M-60HBL JKM320M-60HBL JKM325M-60HBL JKM330M-60HBL STC NOCT STC NOCT STC NOCT SCT NOCT SCT NOCT Maximum Power (Pmax)310Wp 231Wp 315Wp 235Wp 320Wp 239Wp 325Wp 242Wp 330Wp 246Wp Maximum Power Voltage (Vmp)33.0V 31.0V 33.2V 31.2V 33.4V 31.4V 33.6V 31.6V 33.8V 31.8V Maximum Power Current (Imp)9.40A 7.49A 9.49A 7.56A 9.59A 7.62A 9.68A 7.66A 9.77A 7.74A Open-circuit Voltage (Voc)40.5V 37.4V 40.7V 37.6V 40.9V 37.8V 41.1V 38.0V 41.3V 38.2V Short-circuit Current (lsc)9.92A 8.20A 10.04A 8.33A 10.15A 8.44A 10.20A 8.54A 10.31A 8.65A Module Efficiency STC (%)18.37%18.67%18.96%19.26%19.56% ELECTRICAL PERFORMANCE & TEMPERATURE DEPENDENCE BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US The company reserves the final right for explanation on any of the information presented hereby. JKM310-330M-60HL-A2.1-US Voltage (V) Temperature Dependence of Isc, Voc, Pmax Current-Voltage & Power-Voltage Curves (330W) Front Cell Temperature (°C) SPECIFICATIONS -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Temperature Dependence of Isc,Voc,Pmax Mechanical Characteristics -40 ~+85 1000VDC(UL and IEC) 20A -0.36%/ -0.28%/ 0.048%/ 45±2 0~+3% ( Two pallets =One stack ) 26pcs/pallet , 52pcs/stack, 572 pcs/40'HQ Container Packaging Configuration ( Two pallets = One stack ) 31pcs/pallet, 62pcs/stack, 806pcs/40'HQ Container Packaging Configuration Mono PERC Diamond Cell (158.75 x 158.75 mm) 120 (6×20) 19.0 kg (41.9 lbs) Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature (℃) Maximum System Voltage Maximum Series Fuse Rating Power Tolerance Temperature Coefficients of Pmax Temperature Coefficients of Voc Temperature Coefficients of Isc Nominal Operating Cell Temperature (NOCT) 4.5 14 95.5 55 55 3 8 952mm (37.48")1002mm (39.45")A 16 8 4 m m ( 6 6 . 3 0 " ) Cu r r e n t ( A ) 8 6 0 m m ( 3 3 . 8 6 " ) Current-Voltage & Power-Voltage Curves (330W) 5 10 15 20 25 30 35 400 0 2 4 6 8 10 12 0 50 100 150 200 250 300 350 1684×1002×35mm (66.30×39.45×1.38 inch) 3.2mm, Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Junction Box Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) IP67 Rated JKM325M-60HBL 19.26% 325Wp 33.6V 9.68A 41.1V 10.20A 242Wp 7.66A 31.6V 38.0V 8.54A JKM320M-60HBL 18.96% 320Wp 33.4V 9.59A 40.9V 10.15A 239Wp 7.62A 31.4V 37.8V 8.44A JKM315M-60HBL 18.67% 315Wp 33.2V 9.49A 40.7V 10.04A 235Wp 7.56A 31.2V 37.6V 8.33A STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT JKM310M-60HBL 18.37% 310Wp 33.0V 9.40A 40.5V 9.92A 231Wp 7.49A 31.0V 37.4V 8.20A JKM330M-60HBL 19.56% 330Wp 33.8V 9.77A 41.3V 10.31A 246Wp 7.74A 31.8V 38.2V 8.65A CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USIN G THE PRODUCT. © Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. JKM310-330M-60HL-A2.1-US No. of Half Cells 35 35 12AWG, 1825mm (71.85 in) or Customized Length Engineering Drawings Electrical Performance & Temperature Dependence 1 3 6 0 m m ( 5 3 . 5 4 " ) Isc Voc Pmax P o w e r ( W ) No r m a l i z e d I s c , V o c , P m a x ( % ) I III I II III II H SPECIFICATIONS -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Temperature Dependence of Isc,Voc,Pmax Mechanical Characteristics -40 ~+85 1000VDC(UL and IEC) 20A -0.36%/ -0.28%/ 0.048%/ 45±2 0~+3% ( Two pallets =One stack ) 26pcs/pallet , 52pcs/stack, 572 pcs/40'HQ Container Packaging Configuration ( Two pallets = One stack ) 31pcs/pallet, 62pcs/stack, 806pcs/40'HQ Container Packaging Configuration Mono PERC Diamond Cell (158.75 x 158.75 mm) 120 (6×20) 19.0 kg (41.9 lbs) Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature (℃) Maximum System Voltage Maximum Series Fuse Rating Power Tolerance Temperature Coefficients of Pmax Temperature Coefficients of Voc Temperature Coefficients of Isc Nominal Operating Cell Temperature (NOCT) 4.5 14 9 5.5 55 55 3 8 952mm (37.48")1002mm (39.45")A 16 8 4 m m ( 6 6 . 3 0 " ) Cu r r e n t ( A ) 8 6 0 m m ( 3 3 . 8 6 " ) Current-Voltage & Power-Voltage Curves (330W) 5 10 15 20 25 30 35 400 0 2 4 6 8 10 12 0 50 100 150 200 250 300 350 1684×1002×35mm (66.30×39.45×1.38 inch) 3.2mm, Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Junction Box Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) IP67 Rated JKM325M-60HBL 19.26% 325Wp 33.6V 9.68A 41.1V 10.20A 242Wp 7.66A 31.6V 38.0V 8.54A JKM320M-60HBL 18.96% 320Wp 33.4V 9.59A 40.9V 10.15A 239Wp 7.62A 31.4V 37.8V 8.44A JKM315M-60HBL 18.67% 315Wp 33.2V 9.49A 40.7V 10.04A 235Wp 7.56A 31.2V 37.6V 8.33A STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT JKM310M-60HBL 18.37% 310Wp 33.0V 9.40A 40.5V 9.92A 231Wp 7.49A 31.0V 37.4V 8.20A JKM330M-60HBL 19.56% 330Wp 33.8V 9.77A 41.3V 10.31A 246Wp 7.74A 31.8V 38.2V 8.65A CAUTION: REA D SAFETY AND INSTALLATIO N INSTRUCTIONS BEFORE USIN G THE PRODUCT. © Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. JKM31 0-330M-60HL-A2.1-US No. of Half Cells 35 35 12AWG, 1825mm (71.85 in) or Customized Length Engineering Drawings Electrical Performance & Temperature Dependence 1 3 6 0 m m ( 5 3 . 5 4 " ) Isc Voc Pmax P o w e r ( W ) No r m a l i z e d I s c , V o c , P m a x ( % ) I III I II III II H Side Back SPECIFICATIONS -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Temperature Dependence of Isc,Voc,Pmax Mechanical Characteristics -40 ~+85 1000VDC(UL and IEC) 20A -0.36%/ -0.28%/ 0.048%/ 45±2 0~+3% ( Two pallets =One stack ) 26pcs/pallet , 52pcs/stack, 572 pcs/40'HQ Container Packaging Configuration ( Two pallets = One stack ) 31pcs/pallet, 62pcs/stack, 806pcs/40'HQ Container Packaging Configuration Mono PERC Diamond Cell (158.75 x 158.75 mm) 120 (6×20) 19.0 kg (41.9 lbs) Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature (℃) Maximum System Voltage Maximum Series Fuse Rating Power Tolerance Temperature Coefficients of Pmax Temperature Coefficients of Voc Temperature Coefficients of Isc Nominal Operating Cell Temperature (NOCT) 4.5 14 95.5 55 55 3 8 952mm (37.48")1002mm (39.45")A 16 8 4 m m ( 6 6 . 3 0 " ) Cu r r e n t ( A ) 8 6 0 m m ( 3 3 . 8 6 " ) Current-Voltage & Power-Voltage Curves (330W) 5 10 15 20 25 30 35 400 0 2 4 6 8 10 12 0 50 100 150 200 250 300 350 1684×1002×35mm (66.30×39.45×1.38 inch) 3.2mm, Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Junction Box Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) IP67 Rated JKM325M-60HBL 19.26% 325Wp 33.6V 9.68A 41.1V 10.20A 242Wp 7.66A 31.6V 38.0V 8.54A JKM320M-60HBL 18.96% 320Wp 33.4V 9.59A 40.9V 10.15A 239Wp 7.62A 31.4V 37.8V 8.44A JKM315M-60HBL 18.67% 315Wp 33.2V 9.49A 40.7V 10.04A 235Wp 7.56A 31.2V 37.6V 8.33A STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT JKM310M-60HBL 18.37% 310Wp 33.0V 9.40A 40.5V 9.92A 231Wp 7.49A 31.0V 37.4V 8.20A JKM330M-60HBL 19.56% 330Wp 33.8V 9.77A 41.3V 10.31A 246Wp 7.74A 31.8V 38.2V 8.65A CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USIN G THE PRODUCT. © Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. JKM310-330M-60HL-A2.1-US No. of Half Cells 35 35 12AWG, 1825mm (71.85 in) or Customized Length Engineering Drawings Electrical Performance & Temperature Dependence 1 3 6 0 m m ( 5 3 . 5 4 " ) Isc Voc Pmax P o w e r ( W ) No r m a l i z e d I s c , V o c , P m a x ( % ) I III I II III II H Length: ± 2mm Width: ± 2mm Height: ± 1mm Row Pitch: ± 2mm *STC: Irradiance 1000W/m2 NOCT: Irradiance 800W/m2 *Power measurement tolerance: ±3% Cell Temperature 25°C Ambient Temperature 20°C AM = 1.5 AM = 1.5 Wind Speed 1m/s IN V E R T E R S www.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Va c AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, C o u nt r y C o n fi g u ra b l e T h r e s h o l d s Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. PO W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 / P505 Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC OPTIMIZER MODEL (typical module compatibility) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) P505 (for higher current modules) INPUT Rated Input DC Power(1)320 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 83 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(2) Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge SolarEdge Power Optimizer Module Add-On for North America P320 / P370 / P400 / P405 / P505 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)(4) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) P320, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(5) Maximum Power per String 5700 (6000 with SE7600H-US, SE10000H-US) 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice. (3) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf. (4) It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string. (5) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL