HomeMy WebLinkAboutELECTRICAL - 21-00766 - Yellowstone Heights Condos - Bldg 1 - 12 PlexMASTER LUMINAIRE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER VOLTS MOUNTING LAMPS WATTS CONTROL DESCRIPT. LED STRIP LIGHT, 54000 L70, 5-YR. WARRANTY, 5700 LUMENS, 4K, 45W T-1 COLUMBIA CSL4-LSCS 120 CEILING LED (INCLUDED) 45W DESCRIPT. LED RECESSED CAN BY E.C. AS APPROVED BY OWNER T-2 120 RECESSED LED (INCLUDED) 15W DESCRIPT. T-2A SAME AS T-2 EXCEPT WET LISTED DESCRIPT. T-3 HALL/ENTRY LIGHT, LED, BY E.C. AS APPROVED BY OWNER 120 CEILING LED (INCLUDED) 60W DESCRIPT. STUDY LIGHT, LED, BY E.C. AS APPROVED BY OWNER T-4 120 CEILING LED (INCLUDED) 60W DESCRIPT. DINING LIGHT, LED, BY E.C. AS APPROVED BY OWNER T-5 120 CEILING LED (INCLUDED) 60W DESCRIPT. T-6 VANITY LIGHT, LED, BY E.C. AS APPROVED BY OWNER 120 WALL ABOVE VANITY LED (INCLUDED) 30W DESCRIPT. T-7 BATHROOM LIGHT, LED, BY E.C. AS APPROVED BY OWNER 120 CEILING LED (INCLUDED) 60W DESCRIPT. T-8 BEDROOM LIGHT, LED, BY E.C. AS APPROVED BY OWNER 120 CEILING LED (INCLUDED) 60W DESCRIPT. T-9 LIVING ROOM FAN/LIGHT COMBO, LED, BY E.C. AS APPROVED BY OWNER 120 CEILING LED (INCLUDED) 70W DESCRIPT. T-10 BED FAN/LIGHT COMBO, LED BY E.C. AS APPROVED BY OWNER 120 CEILING LED (INCLUDED) _ 70W DESCRIPT. EXTERIOR WALL PACK LIGHT BY E.C. AS APPROVED BY OWNER T-20 120 WALL @ 120" (V.I.F) - 60W DESCRIPT. T-21 LOW PROFILE POLE MOUNTED LUMINAIRE, SINGLE HEAD, TYPE 4 DISTRIBUTION, 4K, VIBRATION DAMPER, 5-YR. WARRANTY, 109.7W, 15200 LUMENS, MOTION/DAYLIGHT SENSOR HUBBELL ASL1-160L-115-41<7-0-120V-ASQU-SWPM-BTS40E-DBT 120 F 25'-POLE LED (INCLUDED) 110W DESCRIPT. rT-2_1A­� SAME AS T-21 EXCEPT DOUBLE HEAD ("I" CONFIGURATION) AND TYPE 5 OPTICS 220W ELECTRICAL SYMBOL & OUTLET SCHEDULE SYMBOL DESCRIPTION MOUNTING HEIGHT WIRING DEVICE NOTES Q CEILING LUMINAIRE CEILING SEE MASTER LUMINAIRE SCHEDULE (1) FD WALL LUMINAIRE (AS NOTED) SEE MASTER LUMINAIRE SCHEDULE (1) ® RECESSED LUMINAIRE RECESSED SEE MASTER LUMINAIRE SCHEDULE (1) (2) o FLUORESCENT/LED LUMINAIRE (AS NOTED) SEE MASTER LUMINAIRE SCHEDULE (1) (2) FLUORESCENT/LED EMERGENCY LUMINAIRE (AS NOTED) SEE MASTER LUMINAIRE SCHEDULE (1) (2) (11) F® WALL MOUNTED EXIT SIGN (NOT SWITCHED) (AS NOTED) SEE MASTER LUMINAIRE SCHEDULE (1) (3) ® CEILING MOUNTED MOUNTED EXIT SIGN (NOT SWITCHED) CEILING SEE MASTER LUMINAIRE SCHEDULE (1) (3) ^Q FLOOD LUMINAIRE (AS NOTED) SEE MASTER LUMINAIRE SCHEDULE (1) POLE MOUNTED LUMINAIRE (SINGLE, DOUBLE, TRIPLE, ETC.) (AS NOTED) SEE MASTER LUMINAIRE SCHEDULE (1) SINGLE —POLE SWITCH 15A 120-277V 4'-0" HUBBELL BBLS121BIW (4) (5) $D DOUBLE —POLE SWITCH 15A 120-277V 4'-0" HUBBELL BBD.268213110 (4) (5) $3 THREE WAY SWITCH 15A 120-277V 4'-0" HUBBELL B6623WBMV (4) (5) FOUR WAY SWITCH 15A 120-277V 4'-0" HUBBELL BBf}83MN (4) (5) VARIABLE INTENSITY SWITCH 4'-0" AS NOTED E FAN SWITCH 4'-0" HUBBELL #DS1201LW (5) THERMAL OVERLOAD SWITCH W/ PILOT LIGHT 4'-0" SQUARE "D" #2510 FG UP (6) T D DOUBLE —POLE THERMAL OVERLOAD SWITCH W/PILOT LIGHT 4'-0" SQUARE "D" 2510—FG2P (6) $M MOTION SENSOR SWITCH 4'-0" WATT STOPPER #WS-250 (10) 4M DOUBLE —POLE MOTION SENSOR SWITCH 4'-0" WATTSTOPPER PW-200—W (10) Q LOW VOLTAGE/KEYED SWITCH 4'-0" (SEE DRAWING/SPEC) 120V, 15A, GROUNDING TYPE DUPLEX RECEPTACLE. 5-15R 18" HUBBELL SNAP5362 (5) (8) P WEATHERPROOF GFI CONVENIENCE RECEPTACLE & COVER 24" HUBBELLGFR536 (5) DUPLEX CONVENIENCE OUTLET — GFI 18" HUBBELL GFR53629MM (5) DOUBLE DUPLEX 120V, 15A, GND. RECEPTACLE 5-15R 18" HUBBELL SNAP5862 (5) (8) (2 EACH) SINGLE CONVENIENCE OUTLET 18" HUBBELL HBL8310INY (5) (8) �# SPECIAL �OV�ER W �P 4R OYI CORD MOUNTG®P2uG " + 3' — 6" HUBBELL (5) VOLT. AMP. PLUG I RECEIPT. PH. WIRE 1. 125 20 A. L320P4 L320R4 1 3W QJ I WALL MOUNTED JUNCTION BOX (AS NOTED) 2. 250 20 A. L420P12 L420R12 3 4W DJ JUNCTION BOX (CEILING, FLOOR OR EQUIPMENT) (AS NOTED) 3. 250 30 A. L430P12 L430R12 3 4W 4. 250 60 A. L460P12 L460R12 3 4W O FAN MOTOR OUTLET (CEILING OR AS NOTED) (AS NOTED) 5. 125 30 A. 9309 9308 1 3W ® MOTOR OUTLET (AS PER EQUIP.) 6. 250 30 A. L430P9 L430R9 1 4W 7.1 250 60 A. L460P9 L460R9 1 4W 8. 1 FLOOR OUTLET POWER ONLY FLOOR T & B 663/P-60-3B (5) ❑� DISCONNECT SWITCH ("F" = FUSED) +5'-0" SQUARE "D" GENERAL DUTY (6) (7) SIZE TO EQUIP. MAGNETIC STARTER +5'-0" SQUARE "D' #8536 (6) (7) SIZE TO EQUIP. MAGNETIC STARTER / DISCONNECT +5'-0" SQUARE "D" #8538 (6) (7) SIZE TO EQUIP. MAGNETIC STARTER COMBINATION +5'-0" SQUARE "D" #8539 (6) (7) SIZE TO EQUIP. ❑HD I HAND DRYER WALL ® 45" (SEE DRAWING/SPEC) ® MAIN ELECTRICAL PANEL BOARD SEE SCHEDULE ELECTRICAL PANEL BOARD TOP ® 6'-6" SEE SCHEDULE O ELECTRONIC EYE WITH RELAY (AS NOTED) TORK 2101(120V) — 2102 (208-277V) (9) ❑T TIMED SWITCH 4'-0" E—Z CONTROL #EZ-701—P-120V (9) 0 PUSH BUTTON 4'-0" OR AS SHOWN SQUARE "D" 9001—BF201 ® RELAY OR POWER PACK AS NOTED (SEE DRAWING/SPEC) DT THERMOSTAT 4'-0" (SEE MECHANICAL) DS MOTION SENSOR CEILING WATTSTOPPER WT-2250 (10) FOS WALL SENSOR WALL WATTSTOPPER DT-200 (10) O TELEPHONE AND OR DATA PANEL TOP ® 6'-6" AS NOTED STANDARD MOUNTING HEIGHT, UNLESS NOTED OTHERWISE (ON PLANS) 0 ARROWHEAD DENOTES HOME RUN TO PANEL (SINGLE CIRCUIT) CONDUIT SHALL BE INSTALLED AS DIAGRAMMED ON THE PLANS, EXCEPT WRITTEN AUTHORIZED CHANGES ARE ISSUED BY THE DESIGNER. —►0 FOUR WIRE DEDICATED NEUTRALS (TWO CIRCUITS) ►►► SIX WIRE DEDICATED NEUTRALS (THREE CIRCUITS) - — — - B' CONDUIT RUN (A) IN WALL OR CEILING, (B) IN FLOOR OR GROUND aI CONDUIT (A) - UP, CONDUIT (B) - DOWN (1) SEE MASTER LUMINAIRE SCHEDULE FOR TYPE, MOUNTING, AND WATTAGE (2) WIRED FROM OUTLET BOX ADJACENT TO LUMINAIRE WHEN INDICATED ON PLAN. (3) REFER TO DRAWINGS FOR DIRECTIONAL ARROWS (4) SUBSCRIPT KEYS SWITCH TO OUTLETS CONTROLLED. (5) EQUALS OF 'BRYANT', 'P&S', OR 'LEVITON', ARE ACCEPTABLE (6) EQUALS OF 'SQUARE-D', 'G.E., OR A-B, ARE ACCEPTABLE. (7) NEMA TYPE "L" UNFUSED, UNLESS NOTED "F" (FUSED); USE "HD" FOR 480-VOLT (8) USE TAMPER RESISTANT RECEPTACLES WHERE REQUIRED BY NEC 406 (9) EQUALS OF 'PARAGON' AND 'INTERMATIC' ARE ACCEPTABLE 10) EQUALS OF 'SENSOR SWITCH', 'LEVITON', 'HUBBELL', ARE ACCEPTABLE. 11) SUPPLY WITH 1100 LUMEN BATTERY BALLAST/CONNECT TO GTD(IF GENERATOR IS AVAILABLE) 12) DATA/TELEPHONE SYSTEM BY OWNER (RACEWAY BY E.C.) TANDEM WIRE BALLAST'S. ABBREVIATIONS E.C.- ELECTRICAL CONTRACTOR M.C.- MECHANICAL CONTRACTOR P.C.- PLUMBING CONTRACTOR G.C.- GENERAL CONTRACTOR T.C.- TEMP. CONTROL CONTR. A.F.F.-ABOVE FINISHED FLOOR A.F.G.-ABOVE FINISHED GRADE B.F.G.-BELOW FINISHED GRADE P.O.C.-POINT OF CONNECTION P.O.S.-POINT OF SALES A.I.C.- AMPS INTERRUPTING CAPACITY S.C.A.-SHORT CIRCUIT AMPS V .I.F.- VERIFY IN FIELD CONT. SERVICE GROUND ---\ CONDUCTOR #3/0 B.C., CODE SIZE OR AS NOTED ON PLANS. 1" PVC CONDUIT CAD -WELD AT THE END AND ANY TWO OTHER POINTS #3/0 BARE COPPER (25' MIN. LENGTH) GROUND CLAMP AND CONNECTOR W/REVERSIBLE CONTACT PLATE 1" PVC GROUND SERVICE CONDUIT TO WATER MAIN 1" PVC GROUND SERVICE CONDUIT TO GROUND ROD I CONCRETE FOOTING REBAR a 2" MIN. 3" MAX. CONDUIT TO EXTEND A MIN. OF 3" ABOVE MUD SILL — 12" FLOOR IF DETAIL - GROUND SYSTEM (2) 5/8" x 8' COPPER GROUND ROD WATER MAIN BLDG. GROUND TO O LUGS (PVC) MAIN PANEL GROUND GROUND CONDUCTOR (CONTINUOUS) FINISHED FLOOR NOTE: THE GROUND CONDUCTOR SHALL BE ONE CONTINUOUS CONDUCTOR. INSTALL IN SECTIONS ONLY WHEN "CAD -WELD" IS ACCEPTABLE BY LOCAL CODE. rA L SCALE 2 NONE FE0.1 GENERAL NOTES 10 ELECTRICAL CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR O1 THE ELECTRICAL NETWORKS DESIGNED HEREIN ARE TO BE CONSTRUCTED AS BUILDING EQUIPMENT, CABINETS, FURNITURE, ETC. AND THE MECHANICAL COMPLETE AND OPERABLE SYSTEMS. POWER, LIGHTING, AUXILIARIES, ETC. SHALL DRAWINGS FOR EXACT LOCATION OF ALL MECHANICAL EQUIPMENT. NO ADDITIONS BE BID AND INSTALLED WITH THIS INTENT AND PURPOSE. THE CONTRACTOR AND TO THE CONTRACT BID WILL BE ALLOWED FOR CHANGES MADE NECESSARY BY THE EQUIPMENT SUPPLIER SHALL VISIT THE SITE AND READ ALL THE RELEVANT INTERFERENCE'S WITH OTHER WORK. NOR WILL ANY EXTRA COST BE ALLOWED IF DOCUMENTS (ARCHITECTURAL, MECHANICAL, ELECTRICAL, ETC.) AND BECOME EQUIPMENT DIMENSIONS ARE LONGER THAN SPECIFIED AND/OR DIMENSIONED ON FAMILIAR WITH THE TYPE OF CONSTRUCTION AND THE WORK TO BE THE PLANS. ACCOMPLISHED. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE PURPOSE 11 LENGTHS OF FLEXIBLE CONDUIT GREATER THAN 48 INCHES SHALL NOT BE FOR WHICH THE PLANS AND SPECIFICATIONS HAVE BEEN PREPARED; AS THE INSTALLED ON THIS PROJECT, EXCEPT WHIPS ON LUMINAIRES, WHICH MAY BE PLANS AND SPECIFICATIONS TOGETHER COVER AND DEFINE THE INSTALLATION OF TWICE THAT LENGTH. FLEXIBLE CONDUIT SHALL NOT BE CONCEALED. EACH SYSTEM AND THE TOTAL FACILITY. FOLLOW THE DOCUMENTS WITH THE INTENT AND PURPOSE TO PRODUCE A COMPLETE AND OPERABLE ELECTRICAL 12 ALL BATTERY POWERED LUMINAIRES SUCH AS EXIT OR EMERGENCY LUMINAIRES, FACILITY, SHOULD ANY ERROR, OMISSION OR CONFLICT EXIST IN EITHER OR BOTH INDICATED ON THE DRAWINGS, SHALL BE CONNECTED TO THE UNSWITCHED LEG THE PLANS AND SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF THE LIGHTING CIRCUIT FEEDING THAT AREA. BEFORE SUBMITTING HIS BID PRICE SO A CHANGE CAN BE ISSUED VIA ADDENDUM, BEFORE THE BID DATE. OTHERWISE, THE CONTRACTOR AND/OR 13 ALL SURFACE MOUNTED FLUORESCENT/LED LUMINAIRES SHALL BE MOUNTED ON EQUIPMENT SUPPLIER SHALL SUPPLY THE PROPER MATERIALS AND LABOR TO CODE DEFINED SPACERS AND/OR HAVE BALLASTS/DRIVERS SUITABLE FOR INSTALL A COMPLETE AND OPERABLE SYSTEM AT THEIR OWN EXPENSE. WHEN AN MOUNTING ON LOW DENSITY TYPE CEILINGS. ELECTRICAL NETWORK IS COMPLETE, TESTS SHALL BE MADE TO ESTABLISH THIS 14 INSTALL ALL LUMINAIRES IN MECHANICAL ROOM AFTER THE MECHANICAL CONDITION. ANY INCOMPLETE SYSTEM SHALL BE MADE OPERABLE. EQUIPMENT IS IN PLACE. ARRANGE SO THAT ALL EQUIPMENT IS ADEQUATELY O2 THIS PROJECT IS TO BE INSTALLED IN STRICT ACCORDANCE WITH LOCAL, STATE ILLUMINATED. AND NEC CODES. IF AT ANYTIME DURING CONSTRUCTION OR THEREAFTER, IS FOUND TO BE INSTALLED IN VIOLATION OF THE "STATED CODES", ?SOMETHING INSTALL A 3/4" CONDUIT WITH ONE (1) #6 BARE CONDUCTOR FROM TELEPHONE IT SHALL BE CORRECTED AT THE CONTRACTORS EXPENSE. BOARD TO THE MAIN GROUNDING BUS. 16 CONTINUOUS EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED WITH ALL O3 THE CONTRACTOR SHALL GROUND THE ELECTRICAL NETWORK IN STRICT ACCORDANCE WITH LOCAL AND NATIONAL CODES. SEE DETAIL 2/E0.1. PHASE CONDUCTORS. BOND GROUNDING CONDUCTORS TO GROUND LUGS, BUSSING, SWITCHES, RECEPTACLES, EQUIPMENT FRAMES, ETC. PER THE NATIONAL ELECTRICAL CODE. WHEN THE MAIN PREMISE GROUNDING SYSTEM HAS BEEN O THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING EQUIPMENT, INSTALLED, E.C. SHALL TEST THE GROUND TO PROVE SYSTEM TO GROUND MATERIALS AND LABOR FOR THE CONNECTION OF ALL EQUIPMENT SHOWN ON THE MEASUREMENTS ARE 5 OHMS OR LESS. ADD ADDITIONAL GROUNDING AS PLANS - ARCHITECTURAL, MECHANICAL, ETC. REQUIRED TO ESTABLISH THIS CONDITION. 5 BEFORE ROUGH -IN, THE CONTRACTOR SHALL ALLOW THE MOVEMENT OF ANY 17 ELECTRICAL RACEWAY INSTALLED WITHIN 1 1/2" OF THE BOTTOM OF ROOF DECK ELECTRICAL PANEL, DEVICE, LUMINAIRE, ETC. A DISTANCE OF 10 FEET WITHOUT SHALL BE RMC OR IMC PER NEC 300.4(E). REQUIRING A COST ADDITION TO THE PROJECT. 18 ALL FIRE WALL PENETRATIONS SHALL BE SEALED WITH UL LISTED SEALANT. O BEFORE ANY ELECTRICAL CONDUIT, BOXES, ETC. ARE COVERED (GROUND, DEVICES INSTALLED IN WALL SHALL BE WRAPPED WITH PUTTY PADS, WHEN CEILINGS, WALLS, ETC.), THEY SHALL RECEIVE THE APPROVAL OF THE REQUIRED BY AHJ. INSPECTING OFFICER (INSPECTOR). THE COST OF UNCOVERING AND REPLACEMENT OF THE ELECTRICAL WORK FOR INSPECTION PURPOSES WILL BE AT THE COST OF 19 ELECTRICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATIONS OF POWER THE ELECTRICAL CONTRACTOR. COMPANY SUPPLIED TRANSFORMER BEFORE INSTALLING SERVICE CONDUIT. O7 ELECTRICAL CONTRACTOR SHALL PROVE MINIMUM CODE (NEC 110-26A) WORKING 20 CONFIRM ROUTING AND SIZE OF TELEPHONE SERVICE CONDUIT AND THE EXACT CLEARANCE BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS AND LOCATION OF THE MAIN TELEPHONE DEMARC WITH THE TELEPHONE COMPANY. SHALL MOVE THE PANELS AT HIS EXPENSE IF REJECTED BY AN INSPECTOR. IF CLEARANCE IS IMPOSSIBLE, THE DESIGNER SHALL BE NOTIFIED IMMEDIATELY INWRITING. 21 UNDERGROUND CONDUIT FOR PARKING LOT LIGHTS SHALL BE BURIED 24" B.F.G. HE SHALL ALSO PROTECT THE SPACE ABOVE THE PANEL IN STRICT AND SHALL HAVE ONE (1) #10 THWN GREEN GROUND CONDUCTOR TO GROUND ACCORDANCE WITH NEC ARTICLE 110-26 (E). ALL LUMINAIRES. O THE ELECTRICAL CONTRACTOR SHALL SURE ALL CONDUIT TO THE STRUCTURE AS 22 ALL ELECTRICAL WORK SHALL COMPLY WITH 2O17 NATIONAL ELECTRICAL CODES. IT IS SET IN PLACE. DO NOT DELAY, AS FIXING IT TO THE STRUCTURE IS SOMETHING FORGOTTEN AS THE WORK PROGRESSES. O9 ELECTRICAL CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF UTILITY (POWER, TELEPHONE, ETC.) SERVICE POINT, PRIOR TO ELECTRICAL ROUGH -IN. NOTE: CUT OFF SHIELDS & OR HEADS MAY BE REQUIRED UPON FIELD INSPECTION. 25'-0" 3#3TIES @ 1-1/2" O.C. IN TOP 6" OF PIER 2'-6„ FACE OF 2'-0" CURB SHEET INDEX E0,1 - NOTES & SCHEDULES E1,1 - ELECTRIC SITE PLAN E2,1 - ELECTRICAL OVERALL FIRST FLOOR PLAN E2.2 - ELECTRICAL OVERALL SECOND FLOOR PLAN E2,3 - ELECTRICAL OVERALL THIRD FLOOR PLAN E3,1 - LIGHTING AND POWER PLANS E3,2 - LIGHTING AND POWER PLANS E4,1 - POWER RISER E4,2 - PANEL SCHEDULES SEE FIXTURE SCHEDULE AS TO FIXTURES TO BE USED. FIXTURE TO INCLUDE KNUCKLE ')"SQ. STEEL POLE 25' HEIGHT 'ACTORY PAINTED MED. BRONZE 'NAMEL WIND RATED FOR AREA. 5"X5" HANDHOLE WITH WEATHERPROOF GASKET BOLT COVER DRYPACK UNDER LIGHT POLE PLATE, FINISH EXPOSED PORTION SMOOTH, SLOPE DOWN TO EDGE. ANCHOR BOLTS & BASEPLATE TO BE DESIGNED BY, DETAILED AND PROVIDED BY LIGHT POLE \ MANUFACTURE. NOTES: d 1. POLE BASE IN NATURAL PIER W/ UNDISTURBED SOIL 2'-0" 0 CONC. 6'-0" MIN. 2. WHEN POLE IS 3'-0" OR GREATER FROM CURB TOP OF POLE FOOTING FLUSH WITH GRADE. 3" CLR. TYP. 2" CLR. 2'-0" DIA. DETAIL - TYPICAL LIGHT POLE & BASE CHAMFER ALL EXPOSED EDGES. HAND RUBBED SAND FINISH RIGID PVC CONDUIT 2'-6" BELOW FINISHED GRADE TO ELECTRICAL PANEL. LONG RADIUS CONDUIT SWEEP. 6-#6 BARS VERT. W/#3 TIES 12" O.C. HORIZ. CONCRETE POLE FOUNDATION SCALE 1 NONE E0.1 OWNERSHIP OF DOCUMENTS his document, including the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSDN ENGINEERING, INC. and shall not be used, in whole or in part, for any other project without the written permission of an authorized representative of NIELSDN ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the law. Copyright Q 2022 byl NIELSDN ENGINEERING, INC. N N i i H CW G 0 W W II z Q f� JULY 31, 2022 Ci-) � 0 S. `O o (a)N I N N � .� N N C o 0 aj X � a Cn O U o N 00 O 0 0 U a' U O Cl- c Q 75 o O c U) o — N z 'a z �w (!) W :� Q D z L LU W 0 (f) U z D Cf) 0 Z W (f) (1) u) � 11­­Z 3:Q Q — Q Z W Z 0 U LU z�Do LL LU J W O _j _J 0 nL D v J W m a P W 0 W +' Utz_Joc� a, o > in a Ln file name job no. 2214 date MARCH 2O22 drawn by EIS sheet E 0 1 of 9