HomeMy WebLinkAboutTRUSS DESIGN - 21-00814 - 2943 W 3800 S - Strong Shed with Living Space.pdfAlpine, an ITW Company 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Phone: (800)877-3678 (916)387-0116 Fax: (916)387-1110 sacseals@itwbcg.com Site Information:Page 1: Customer: Franklin Building Supply Job Number: 219547J Job Description: -SAGE BUILDERS Address: 2943 W 3800 S. , Rexburg, ID 83442 Job Engineering Criteria: Design Code: IBC 2021 IntelliVIEW Version: 21.02.00 JRef #: 1XbQ65190008 Wind Standard: ASCE 7-16 Wind Speed (mph): 115 Design Loading (psf): 51.00 Building Type: Closed This package contains general notes pages, 11 truss drawing(s) and 5 detail(s). Item Drawing Number Truss Item Drawing Number Truss 1 362.21.1432.20130 A1 2 362.21.1432.21820 A2 3 362.21.1432.23193 A3 4 362.21.1432.32457 A4 5 362.21.1432.35460 A5 6 362.21.1432.38707 CJ1 7 362.21.1432.40053 CJ2 8 362.21.1432.41347 CJ3 9 362.21.1432.54367 EJ1 10 362.21.1432.58533 EJ2 11 362.21.1433.12447 HJ1 12 A11530ENC160118 13 GABRST160118 14 GBLLETIN0118 15 BRCLBSUB0119 16 A11515ENC160118 Printed 12/28/2021 2:33:17 PM 12/28/2021 General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those spec ified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer’s seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections . This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR -1118, available on-line at www.icc-es.org. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re-dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non-Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non-hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www. sbcacomponents.com. Page 3 of 3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11530ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 821 /-/-/264 /189 /104 V*189 /-/-/50 /30 /- Wind reactions based on MWFRS B Brg Wid = 5.5 Min Req =1.5 (Truss) V Brg Wid = 474 Min Req =- Bearings B & B Fcperp = 625psi. Members not listed have forces less than 375# Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AN 169 -577 G -AJ 129 -412 I -AI 129 -432 J -AH 163 -424 K -AG 251 -486 Gables Tens.Comp. AE- M 251 -486 AD- N 163 -424 AC- O 129 -432 AB- Q 129 -412 X - U 169 -577 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.86 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.012 V 999 240 VERT(CL):0.019 V 999 180 HORZ(LL):0.004 B - - HORZ(TL):0.007 B - - Creep Factor: 2.0 Max TC CSI:0.610 Max BC CSI:0.175 Max Web CSI:0.197 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A1 Ply: 1 Qty:2 SEQN:309637 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T13 DrwNo:362.21.1432.20130 /CA 12/28/2021 40' 4'2'(TYP) 20' 20' 40' 20' 40' 40'2'2' 4"85'4"85'9"10A B C G H I J K L M N O P Q U V W XABACADAEAGAHAIAJAN 3 12 3X6(A1T) 3X6 5X6 5X6 5X6 3X6 3X6(A1T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11530ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 821 /-/-/264 /189 /104 V*189 /-/-/50 /30 /- Wind reactions based on MWFRS B Brg Wid = 5.5 Min Req =1.5 (Truss) V Brg Wid = 474 Min Req =- Bearings B & B Fcperp = 625psi. Members not listed have forces less than 375# Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AN 169 -577 G -AJ 129 -412 I -AI 129 -432 J -AH 163 -424 K -AG 251 -486 Gables Tens.Comp. AE- M 251 -486 AD- N 163 -424 AC- O 129 -432 AB- Q 129 -412 X - U 169 -577 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.86 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.012 V 999 240 VERT(CL):0.019 V 999 180 HORZ(LL):0.004 B - - HORZ(TL):0.007 B - - Creep Factor: 2.0 Max TC CSI:0.610 Max BC CSI:0.175 Max Web CSI:0.197 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A1 Ply: 1 Qty:2 SEQN:309637 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T13 DrwNo:362.21.1432.20130 /CA 12/28/2021 40' 4'2'(TYP) 20' 20' 40' 20' 40' 40'2'2' 4"85'4"85'9"10A B C G H I J K L M N O P Q U V W XABACADAEAGAHAIAJAN 3 12 3X6(A1T) 3X6 5X6 5X6 5X6 3X6 3X6(A1T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L 2400f-2.0E T2, T3 2x4 DF-L #1&Bet.; Bot chord 2x4 DF-L 2400f-2.0E B2 2x4 DF-L #1&Bet.; Webs 2x4 DF-L Stud W 3,W 5 2x4 DF-L #1&Bet.; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 29" oc, BC @ 80" oc. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 2226 /-/-/697 /225 /52 H 2226 /-/-/697 /225 /- Wind reactions based on MWFRS B Brg Wid = 5.5 Min Req =2.2 (Truss) H Brg Wid = 5.5 Min Req =2.2 (Truss) Bearings B & H Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1302 -6569 C - D 1162 -5932 D - E 946 -4239 Chords Tens.Comp. E - F 946 -4239 F - G 1163 -5932 G - H 1302 -6569 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - N 6303 -1210 N - M 5260 -1031 M - L 5260 -1031 Chords Tens.Comp. L - K 5260 -1012 K - J 5260 -1012 J - H 6303 -1191 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - N 252 -704 N - D 657 -27 D - L 337 -1652 E - L 1465 -233 Webs Tens.Comp. L - F 337 -1652 F - J 657 -27 J - G 252 -704 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.86 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.732 L 651 240 VERT(CL):1.057 L 450 180 HORZ(LL):0.180 H - - HORZ(TL):0.262 H - - Creep Factor: 2.0 Max TC CSI:0.961 Max BC CSI:0.975 Max Web CSI:0.998 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A2 Ply: 1 Qty:62 SEQN:309633 COMN FROM: Cust: R 6519 JRef:1XbQ65190008 T8 DrwNo:362.21.1432.21820 /CA 12/28/2021 T2 T3 B2 W3 W5 40' 7'2"15 7'2"15 13'6"8 6'3"8 20' 6'5"8 26'5"8 6'5"8 32'9"1 6'3"8 40' 7'2"15 10'5"3 10'5"3 20' 9'6"13 29'6"13 9'6"13 40' 10'5"32'2' 4"85'4"85'9"10(a)(a) A B C D E F G H I JKLMN 3 12 4X12(B1T) 2X4 3X6 5X6 SS0312 5X6 5X8 SS0312 5X6 3X6 2X4 4X12(B1T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L 2400f-2.0E T2, T3 2x4 DF-L #1&Bet.; Bot chord 2x4 DF-L 2400f-2.0E B2 2x4 DF-L #1&Bet.; Webs 2x4 DF-L Stud W 3,W 5 2x4 DF-L #1&Bet.; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 29" oc, BC @ 80" oc. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 2226 /-/-/697 /225 /52 H 2226 /-/-/697 /225 /- Wind reactions based on MWFRS B Brg Wid = 5.5 Min Req =2.2 (Truss) H Brg Wid = 5.5 Min Req =2.2 (Truss) Bearings B & H Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1302 -6569 C - D 1162 -5932 D - E 946 -4239 Chords Tens.Comp. E - F 946 -4239 F - G 1163 -5932 G - H 1302 -6569 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - N 6303 -1210 N - M 5260 -1031 M - L 5260 -1031 Chords Tens.Comp. L - K 5260 -1012 K - J 5260 -1012 J - H 6303 -1191 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - N 252 -704 N - D 657 -27 D - L 337 -1652 E - L 1465 -233 Webs Tens.Comp. L - F 337 -1652 F - J 657 -27 J - G 252 -704 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.86 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.732 L 651 240 VERT(CL):1.057 L 450 180 HORZ(LL):0.180 H - - HORZ(TL):0.262 H - - Creep Factor: 2.0 Max TC CSI:0.961 Max BC CSI:0.975 Max Web CSI:0.998 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A2 Ply: 1 Qty:62 SEQN:309633 COMN FROM: Cust: R 6519 JRef:1XbQ65190008 T8 DrwNo:362.21.1432.21820 /CA 12/28/2021 T2 T3 B2 W3 W5 40' 7'2"15 7'2"15 13'6"8 6'3"8 20' 6'5"8 26'5"8 6'5"8 32'9"1 6'3"8 40' 7'2"15 10'5"3 10'5"3 20' 9'6"13 29'6"13 9'6"13 40' 10'5"32'2' 4"85'4"85'9"10(a)(a) A B C D E F G H I JKLMN 3 12 4X12(B1T) 2X4 3X6 5X6 SS0312 5X6 5X8 SS0312 5X6 3X6 2X4 4X12(B1T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L 2400f-2.0E T2, T3 2x4 DF-L #1&Bet.; Bot chord 2x4 DF-L 2400f-2.0E B2 2x4 DF-L #1&Bet.; Webs 2x4 DF-L Stud W 3,W 5 2x4 DF-L #1&Bet.; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 27" oc, BC @ 79" oc. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL O 2226 /-/-/697 /225 /52 H 2226 /-/-/697 /225 /- Wind reactions based on MWFRS O Brg Wid = 5.5 Min Req =2.2 (Truss) H Brg Wid = 5.5 Min Req =2.2 (Truss) Bearings O & H Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1337 -6763 C - D 1188 -6075 D - E 952 -4280 Chords Tens.Comp. E - F 952 -4280 F - G 1188 -6075 G - H 1337 -6763 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - N 6502 -1246 N - M 5345 -1047 M - L 5345 -1047 Chords Tens.Comp. L - K 5345 -1028 K - J 5345 -1028 J - H 6502 -1227 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - N 264 -772 N - D 726 -40 D - L 347 -1697 E - L 1480 -235 Webs Tens.Comp. L - F 347 -1697 F - J 726 -40 J - G 264 -772 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.80 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.750 L 635 240 VERT(CL):1.090 L 437 180 HORZ(LL):0.186 H - - HORZ(TL):0.273 H - - Creep Factor: 2.0 Max TC CSI:0.995 Max BC CSI:0.963 Max Web CSI:0.495 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A3 Ply: 1 Qty:4 SEQN:309641 COMN FROM: Cust: R 6519 JRef:1XbQ65190008 T11 DrwNo:362.21.1432.23193 /CA 12/28/2021 T2 T3 B2 W3 W5 40' 7'2"15 7'2"15 13'6"8 6'3"8 20' 6'5"8 26'5"8 6'5"8 32'9"1 6'3"8 40' 7'2"15 10'5"3 10'5"3 20' 9'6"13 29'6"13 9'6"13 40' 10'5"32'2' 3"145'3"145'9"10(a)(a) A B C D E F G H I JKLMNO 3 12 4X12(A2T) 2X4 3X6 5X6 SS0312 5X6 5X8 SS0312 5X6 3X6 2X4 4X12(A2T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L 2400f-2.0E T2, T3 2x4 DF-L #1&Bet.; Bot chord 2x4 DF-L 2400f-2.0E B2 2x4 DF-L #1&Bet.; Webs 2x4 DF-L Stud W 3,W 5 2x4 DF-L #1&Bet.; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 27" oc, BC @ 79" oc. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL O 2226 /-/-/697 /225 /52 H 2226 /-/-/697 /225 /- Wind reactions based on MWFRS O Brg Wid = 5.5 Min Req =2.2 (Truss) H Brg Wid = 5.5 Min Req =2.2 (Truss) Bearings O & H Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1337 -6763 C - D 1188 -6075 D - E 952 -4280 Chords Tens.Comp. E - F 952 -4280 F - G 1188 -6075 G - H 1337 -6763 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - N 6502 -1246 N - M 5345 -1047 M - L 5345 -1047 Chords Tens.Comp. L - K 5345 -1028 K - J 5345 -1028 J - H 6502 -1227 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - N 264 -772 N - D 726 -40 D - L 347 -1697 E - L 1480 -235 Webs Tens.Comp. L - F 347 -1697 F - J 726 -40 J - G 264 -772 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.80 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.750 L 635 240 VERT(CL):1.090 L 437 180 HORZ(LL):0.186 H - - HORZ(TL):0.273 H - - Creep Factor: 2.0 Max TC CSI:0.995 Max BC CSI:0.963 Max Web CSI:0.495 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A3 Ply: 1 Qty:4 SEQN:309641 COMN FROM: Cust: R 6519 JRef:1XbQ65190008 T11 DrwNo:362.21.1432.23193 /CA 12/28/2021 T2 T3 B2 W3 W5 40' 7'2"15 7'2"15 13'6"8 6'3"8 20' 6'5"8 26'5"8 6'5"8 32'9"1 6'3"8 40' 7'2"15 10'5"3 10'5"3 20' 9'6"13 29'6"13 9'6"13 40' 10'5"32'2' 3"145'3"145'9"10(a)(a) A B C D E F G H I JKLMNO 3 12 4X12(A2T) 2X4 3X6 5X6 SS0312 5X6 5X8 SS0312 5X6 3X6 2X4 4X12(A2T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 0-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11530ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AO 429 /-/-/146 /87 /52 B*95 /-/-/31 /9 /- V 429 /-/-/153 /93 /- Wind reactions based on MWFRS AO Brg Wid = 5.5 Min Req =1.5 (Truss) B Brg Wid = 469 Min Req =- V Brg Wid = 5.5 Min Req =1.5 (Truss) Bearings AO, B, & V Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.80 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.009 V 999 240 VERT(CL):0.013 V 999 180 HORZ(LL):0.003 B - - HORZ(TL):0.004 B - - Creep Factor: 2.0 Max TC CSI:0.271 Max BC CSI:0.095 Max Web CSI:0.104 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A4 Ply: 1 Qty:2 SEQN:309643 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T9 DrwNo:362.21.1432.32457 /CA 12/28/2021 5"8 39'1"5"8 4'2'(TYP) 20' 20' 40' 20' 40' 40'2'2' 3"145'3"145'9"10A B H L P V W ADAHAO 3 12 3X6(A1T) 3X6 5X6 5X6 5X6 3X6 3X6(A1T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 0-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11530ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AO 429 /-/-/146 /87 /52 B*95 /-/-/31 /9 /- V 429 /-/-/153 /93 /- Wind reactions based on MWFRS AO Brg Wid = 5.5 Min Req =1.5 (Truss) B Brg Wid = 469 Min Req =- V Brg Wid = 5.5 Min Req =1.5 (Truss) Bearings AO, B, & V Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.80 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.009 V 999 240 VERT(CL):0.013 V 999 180 HORZ(LL):0.003 B - - HORZ(TL):0.004 B - - Creep Factor: 2.0 Max TC CSI:0.271 Max BC CSI:0.095 Max Web CSI:0.104 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A4 Ply: 1 Qty:2 SEQN:309643 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T9 DrwNo:362.21.1432.32457 /CA 12/28/2021 5"8 39'1"5"8 4'2'(TYP) 20' 20' 40' 20' 40' 40'2'2' 3"145'3"145'9"10A B H L P V W ADAHAO 3 12 3X6(A1T) 3X6 5X6 5X6 5X6 3X6 3X6(A1T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11530ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 823 /-/-/266 /187 /114 B*140 /-/-/36 /23 /- AJ 377 /-/-/101 /66 /- V*187 /-/-/50 /28 /- Wind reactions based on MWFRS B Brg Wid = 5.5 Min Req =1.5 (Truss) B Brg Wid = 114 Min Req =- AJ Brg Wid = 5.5 Min Req =1.5 (Truss) V Brg Wid = 354 Min Req =- Bearings B, B, AJ, & AJ Fcperp = 625psi. Members not listed have forces less than 375# Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AM 168 -577 G -AI 129 -396 I -AH 129 -429 J -AG 163 -420 K -AF 251 -482 Gables Tens.Comp. AD- M 251 -486 AC- N 163 -424 AB- O 129 -431 AA- Q 129 -412 W -U 209 -578 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.86 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.014 V 999 240 VERT(CL):0.019 V 999 180 HORZ(LL):-0.004 V - - HORZ(TL):0.006 B - - Creep Factor: 2.0 Max TC CSI:0.621 Max BC CSI:0.197 Max Web CSI:0.197 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A5 Ply: 1 Qty:2 SEQN:309639 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T2 DrwNo:362.21.1432.35460 /CA 12/28/2021 5"8 9'6"8 2"12 29'9"4 4'2'(TYP) 20' 20' 40' 20' 40' 40'2' 4"85'4"85'9"10A B C G H I J K L M N OP Q U V WAAABACADAFAGAHAIAJAM 3 12 3X6(A1T) 3X6 5X6 5X6 5X6 3X6 3X6(A1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11530ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 823 /-/-/266 /187 /114 B*140 /-/-/36 /23 /- AJ 377 /-/-/101 /66 /- V*187 /-/-/50 /28 /- Wind reactions based on MWFRS B Brg Wid = 5.5 Min Req =1.5 (Truss) B Brg Wid = 114 Min Req =- AJ Brg Wid = 5.5 Min Req =1.5 (Truss) V Brg Wid = 354 Min Req =- Bearings B, B, AJ, & AJ Fcperp = 625psi. Members not listed have forces less than 375# Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AM 168 -577 G -AI 129 -396 I -AH 129 -429 J -AG 163 -420 K -AF 251 -482 Gables Tens.Comp. AD- M 251 -486 AC- N 163 -424 AB- O 129 -431 AA- Q 129 -412 W -U 209 -578 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 19.86 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.014 V 999 240 VERT(CL):0.019 V 999 180 HORZ(LL):-0.004 V - - HORZ(TL):0.006 B - - Creep Factor: 2.0 Max TC CSI:0.621 Max BC CSI:0.197 Max Web CSI:0.197 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:A5 Ply: 1 Qty:2 SEQN:309639 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T2 DrwNo:362.21.1432.35460 /CA 12/28/2021 5"8 9'6"8 2"12 29'9"4 4'2'(TYP) 20' 20' 40' 20' 40' 40'2' 4"85'4"85'9"10A B C G H I J K L M N OP Q U V WAAABACADAFAGAHAIAJAM 3 12 3X6(A1T) 3X6 5X6 5X6 5X6 3X6 3X6(A1) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 49" oc, BC @ 21" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 398 /-/-/144 /102 /31 D 32 /-25 /-/25 /11 /- C 58 /-1 /-/20 /16 /- Wind reactions based on MWFRS E Brg Wid = 3.5 Min Req =1.5 (Truss) D Brg Wid = 1.5 Min Req =- C Brg Wid = 1.5 Min Req =- Bearing E Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.001 B - - HORZ(TL):0.001 B - - Creep Factor: 2.0 Max TC CSI:0.251 Max BC CSI:0.047 Max Web CSI:0.000 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:CJ1 Ply: 1 Qty:2 SEQN:309656 JACK FROM: Cust: R 6519 JRef:1XbQ65190008 T23 DrwNo:362.21.1432.38707 /CA 12/28/2021 1'10"15 1'10"152' 3"14 9"91'3"5A B C DE 3 12 2X4(A1T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 49" oc, BC @ 21" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 398 /-/-/144 /102 /31 D 32 /-25 /-/25 /11 /- C 58 /-1 /-/20 /16 /- Wind reactions based on MWFRS E Brg Wid = 3.5 Min Req =1.5 (Truss) D Brg Wid = 1.5 Min Req =- C Brg Wid = 1.5 Min Req =- Bearing E Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.001 B - - HORZ(TL):0.001 B - - Creep Factor: 2.0 Max TC CSI:0.251 Max BC CSI:0.047 Max Web CSI:0.000 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:CJ1 Ply: 1 Qty:2 SEQN:309656 JACK FROM: Cust: R 6519 JRef:1XbQ65190008 T23 DrwNo:362.21.1432.38707 /CA 12/28/2021 1'10"15 1'10"152' 3"14 9"91'3"5A B C DE 3 12 2X4(A1T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 74" oc, BC @ 45" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 439 /-/-/154 /83 /43 D 56 /-/-/27 /-/- C 138 /-/-/28 /23 /- Wind reactions based on MWFRS E Brg Wid = 3.5 Min Req =1.5 (Truss) D Brg Wid = 1.5 Min Req =- C Brg Wid = 1.5 Min Req =- Bearing E Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.004 B - - HORZ(TL):0.006 B - - Creep Factor: 2.0 Max TC CSI:0.287 Max BC CSI:0.117 Max Web CSI:0.000 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:CJ2 Ply: 1 Qty:2 SEQN:309654 JACK FROM: Cust: R 6519 JRef:1XbQ65190008 T7 DrwNo:362.21.1432.40053 /CA 12/28/2021 3'10"15 3'10"152' 3"14 1'3"91'9"5A B C DE 3 12 2X4(A1T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 74" oc, BC @ 45" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 439 /-/-/154 /83 /43 D 56 /-/-/27 /-/- C 138 /-/-/28 /23 /- Wind reactions based on MWFRS E Brg Wid = 3.5 Min Req =1.5 (Truss) D Brg Wid = 1.5 Min Req =- C Brg Wid = 1.5 Min Req =- Bearing E Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.004 B - - HORZ(TL):0.006 B - - Creep Factor: 2.0 Max TC CSI:0.287 Max BC CSI:0.117 Max Web CSI:0.000 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:CJ2 Ply: 1 Qty:2 SEQN:309654 JACK FROM: Cust: R 6519 JRef:1XbQ65190008 T7 DrwNo:362.21.1432.40053 /CA 12/28/2021 3'10"15 3'10"152' 3"14 1'3"91'9"5A B C DE 3 12 2X4(A1T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 69" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 522 /-/-/180 /79 /55 D 92 /-/-/45 /-/- C 216 /-/-/47 /40 /- Wind reactions based on MWFRS E Brg Wid = 3.5 Min Req =1.5 (Truss) D Brg Wid = 1.5 Min Req =- C Brg Wid = 1.5 Min Req =- Bearing E Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.014 B - - HORZ(TL):0.021 B - - Creep Factor: 2.0 Max TC CSI:0.462 Max BC CSI:0.252 Max Web CSI:0.000 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:CJ3 Ply: 1 Qty:2 SEQN:309652 JACK FROM: Cust: R 6519 JRef:1XbQ65190008 T18 DrwNo:362.21.1432.41347 /CA 12/28/2021 5'10"15 5'10"152' 3"14 1'9"92'3"5A B C DE 3 12 2X4(A1T) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 69" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 522 /-/-/180 /79 /55 D 92 /-/-/45 /-/- C 216 /-/-/47 /40 /- Wind reactions based on MWFRS E Brg Wid = 3.5 Min Req =1.5 (Truss) D Brg Wid = 1.5 Min Req =- C Brg Wid = 1.5 Min Req =- Bearing E Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.014 B - - HORZ(TL):0.021 B - - Creep Factor: 2.0 Max TC CSI:0.462 Max BC CSI:0.252 Max Web CSI:0.000 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:CJ3 Ply: 1 Qty:2 SEQN:309652 JACK FROM: Cust: R 6519 JRef:1XbQ65190008 T18 DrwNo:362.21.1432.41347 /CA 12/28/2021 5'10"15 5'10"152' 3"14 1'9"92'3"5A B C DE 3 12 2X4(A1T) 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x6 DF-L SS Webs 2x4 DF-L Stud Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 92" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL F 611 /-/-/208 /79 /67 E 405 /-/-/127 /37 /- Wind reactions based on MWFRS F Brg Wid = 3.5 Min Req =1.5 (Truss) E Brg Wid = 1.5 Min Req =1.5 (Support) Bearings F & E Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 344 -643 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - E 609 -428 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - E 459 -646 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.026 B 999 240 VERT(CL):0.038 B 999 180 HORZ(LL):0.006 B - - HORZ(TL):0.008 B - - Creep Factor: 2.0 Max TC CSI:0.538 Max BC CSI:0.173 Max Web CSI:0.168 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:EJ1 Ply: 1 Qty:18 SEQN:309650 MONO FROM: Cust: R 6519 JRef:1XbQ65190008 T29 DrwNo:362.21.1432.54367 /CA 12/28/2021 7'11"8 4'8"8 4'8"8 7'11"8 3'3" 7'9"14 7'9"14 7'11"8 1"10 2' 3"14 5"81'10"42'3"122'9"8A B C D EF 3 12 2X4(A1T) 2X4 3X6 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x6 DF-L SS Webs 2x4 DF-L Stud Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 92" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL F 611 /-/-/208 /79 /67 E 405 /-/-/127 /37 /- Wind reactions based on MWFRS F Brg Wid = 3.5 Min Req =1.5 (Truss) E Brg Wid = 1.5 Min Req =1.5 (Support) Bearings F & E Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 344 -643 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - E 609 -428 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - E 459 -646 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.026 B 999 240 VERT(CL):0.038 B 999 180 HORZ(LL):0.006 B - - HORZ(TL):0.008 B - - Creep Factor: 2.0 Max TC CSI:0.538 Max BC CSI:0.173 Max Web CSI:0.168 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:EJ1 Ply: 1 Qty:18 SEQN:309650 MONO FROM: Cust: R 6519 JRef:1XbQ65190008 T29 DrwNo:362.21.1432.54367 /CA 12/28/2021 7'11"8 4'8"8 4'8"8 7'11"8 3'3" 7'9"14 7'9"14 7'11"8 1"10 2' 3"14 5"81'10"42'3"122'9"8A B C D EF 3 12 2X4(A1T) 2X4 3X6 2X4 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x6 DF-L SS Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-4-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 92" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11515ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL I 710 /-/-/228 /248 /152 F 508 /-/-/154 /174 /- Wind reactions based on MWFRS I Brg Wid = 3.5 Min Req =1.5 (Truss) F Brg Wid = 1.5 Min Req =1.5 (Support) Bearings I & F Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.146 H 630 240 VERT(CL):0.196 H 471 180 HORZ(LL):0.037 C - - HORZ(TL):0.049 C - - Creep Factor: 2.0 Max TC CSI:0.357 Max BC CSI:0.457 Max Web CSI:0.132 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:EJ2 Ply: 1 Qty:2 SEQN:309648 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T22 DrwNo:362.21.1432.58533 /CA 12/28/2021 7'11"8 4' 4' 6' 2' 7'11"8 1'11"8 4' 4' 6' 2' 7'9"14 1'9"14 7'11"8 1"10 2' 3"14 5"81'10"42'3"122'9"8A B E FI 3 12 2X4(A1T)4X8 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x6 DF-L SS Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-4-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 75" oc, BC @ 92" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Member design based on both MWFRS and C&C. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A11515ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL I 710 /-/-/228 /248 /152 F 508 /-/-/154 /174 /- Wind reactions based on MWFRS I Brg Wid = 3.5 Min Req =1.5 (Truss) F Brg Wid = 1.5 Min Req =1.5 (Support) Bearings I & F Fcperp = 625psi. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.146 H 630 240 VERT(CL):0.196 H 471 180 HORZ(LL):0.037 C - - HORZ(TL):0.049 C - - Creep Factor: 2.0 Max TC CSI:0.357 Max BC CSI:0.457 Max Web CSI:0.132 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:EJ2 Ply: 1 Qty:2 SEQN:309648 GABL FROM: Cust: R 6519 JRef:1XbQ65190008 T22 DrwNo:362.21.1432.58533 /CA 12/28/2021 7'11"8 4' 4' 6' 2' 7'11"8 1'11"8 4' 4' 6' 2' 7'9"14 1'9"14 7'11"8 1"10 2' 3"14 5"81'10"42'3"122'9"8A B E FI 3 12 2X4(A1T)4X8 12/28/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x6 DF-L SS Webs 2x4 DF-L Stud W 3 2x6 DF-L SS; Special Loads ------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15) TC: From 0 plf at -2.82 to 86 plf at -0.05 TC: From 2 plf at -0.05 to 2 plf at 11.26 BC: From 2 plf at 0.00 to 2 plf at 11.06 TC: 115 lb Conc. Load at 2.81 TC: 276 lb Conc. Load at 5.64 TC: 432 lb Conc. Load at 8.47 BC: 64 lb Conc. Load at 2.81 BC: 112 lb Conc. Load at 5.64 BC: 183 lb Conc. Load at 8.47 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 46" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 624 /-/-/-/82 /- E 734 /-/-/-/50 /- Wind reactions based on MWFRS G Brg Wid = 3.4 Min Req =1.5 (Truss) E Brg Wid = 2.1 Min Req =1.5 (Support) Bearings G & E Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 173 -2128 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 2080 -166 Chords Tens.Comp. F - E 2054 -170 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - E 168 -2034 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.087 F 999 240 VERT(CL):0.131 F 999 180 HORZ(LL):0.013 E - - HORZ(TL):0.019 E - - Creep Factor: 2.0 Max TC CSI:0.978 Max BC CSI:0.389 Max Web CSI:0.848 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:HJ1 Ply: 1 Qty:1 SEQN:309646 HIP_ FROM: Cust: R 6519 JRef:1XbQ65190008 T1 DrwNo:362.21.1433.12447 /CA 12/28/2021 W3 11'2"5 6'3"9 6'3"9 11'3"1 4'11"8 6'3"9 6'3"9 11'0"12 4'9"3 11'3"1 2"5 2'9"3 3"14 5"81'10"42'3"122'9"5A B C D EFG 2.12 12 2X4(A3T) 2X4(A3T) 2X4 4X6 5X6 3X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org Franklin Building Supply 515 W. Main Appleton ID 83338 (208)324-8228 8801 Folsom Blvd., Suite 107 Sacramento, CA 95826 Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x6 DF-L SS Webs 2x4 DF-L Stud W 3 2x6 DF-L SS; Special Loads ------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15) TC: From 0 plf at -2.82 to 86 plf at -0.05 TC: From 2 plf at -0.05 to 2 plf at 11.26 BC: From 2 plf at 0.00 to 2 plf at 11.06 TC: 115 lb Conc. Load at 2.81 TC: 276 lb Conc. Load at 5.64 TC: 432 lb Conc. Load at 8.47 BC: 64 lb Conc. Load at 2.81 BC: 112 lb Conc. Load at 5.64 BC: 183 lb Conc. Load at 8.47 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels or rigid ceiling use purlins to brace TC @ 46" oc, BC @ 120" oc. Purlin spacing for bracing only; uniform distribution of loads is required. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 624 /-/-/-/82 /- E 734 /-/-/-/50 /- Wind reactions based on MWFRS G Brg Wid = 3.4 Min Req =1.5 (Truss) E Brg Wid = 2.1 Min Req =1.5 (Support) Bearings G & E Fcperp = 625psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 173 -2128 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 2080 -166 Chords Tens.Comp. F - E 2054 -170 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - E 168 -2034 Loading Criteria (psf) TCLL:35.00 TCDL:8.00 BCLL:0.00 BCDL:8.00 Des Ld:51.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: -CAT: - Pf: 35.0 Ce: - Lu: -Cs: - Snow Duration: - Building Code: IBC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.087 F 999 240 VERT(CL):0.131 F 999 180 HORZ(LL):0.013 E - - HORZ(TL):0.019 E - - Creep Factor: 2.0 Max TC CSI:0.978 Max BC CSI:0.389 Max Web CSI:0.848 VIEW Ver: 21.02.00.1005.17 Job Number:219547J -SAGE BUILDERS Truss Label:HJ1 Ply: 1 Qty:1 SEQN:309646 HIP_ FROM: Cust: R 6519 JRef:1XbQ65190008 T1 DrwNo:362.21.1433.12447 /CA 12/28/2021 W3 11'2"5 6'3"9 6'3"9 11'3"1 4'11"8 6'3"9 6'3"9 11'0"12 4'9"3 11'3"1 2"5 2'9"3 3"14 5"81'10"42'3"122'9"5A B C D EFG 2.12 12 2X4(A3T) 2X4(A3T) 2X4 4X6 5X6 3X6 12/28/2021 514 Earth City Expressway Suite 242 Earth City, MO 63045 12/28/2021 514 Earth City Expressway Suite 242 Earth City, MO 63045 12/28/2021 514 Earth City Expressway Suite 242 Earth City, MO 63045 12/28/2021 514 Earth City Expressway Suite 242 Earth City, MO 63045 12/28/2021 514 Earth City Expressway Suite 242 Earth City, MO 63045 12/28/2021