HomeMy WebLinkAboutFIRE ALARM SUBMITTAL - 20-00866 - BYUI Engineering Technology Center (ETC) - Remodel FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 BYU-I ETC Upgrade 525 South Center Street Rexburg, ID. 83440 Engineer Technology Center Upgrade BYU-Idaho Fire Alarm System Submittal & Drawings PROJECT Equipment Manufacturer: Gamewell-FCI Engineering Technology Center Authorized Distributor: Nelson Fire Systems Upgrade 1481 S Major St BYU-Idaho SLC, UT 84115 Fire Alarm System 801-468-8300... BYU-I ETC Upgrade 525 South Center Street Rexburg, ID. 83440 TABLE OF CONTENTS Data Sheet Part No. Description Gamewell-FCI E3 Series Emergency Evacuation System Gamewell-FCI ILI-MB-E3 E3 Series Intelligent Loop Module Gamewell-FCI ASM-16 E3 Series Auxiliary Relay Gamewell-FCI LCD-E3 E3 Series LCD Display Gamewell-FCI PM-9 E3 Series Power Supply Gamewell-FCI INI-VGX-UTP E3 Series Voice Gateway Gamewell-FCI INCC-MIC E3 Series Microphone Gamewell-FCI AM-50 E3 Series Voice Amplifier Gamewell-FCI ASD-PL3/B300-6 Addressable Photo Smoke Detector w/Base Gamewell-FCI AMM-4F Addressable Monitor Module Gamewell-FCI DNR w/DST-5 Duct Detector Housing w/Sampling Tube Gamewell-FCI PR-3 Relay Gamewell-FCI SCWL Strobe Only – Ceiling Mount Gamewell-FCI SPCWL Speaker Only – Ceiling Mount Gamewell-FCI SPSCWL Speaker/Strobe – Ceiling Mount Gamewell-FCI SPSRK Weatherproof Speaker/Strobe – Wall Mount Gamewell-FCI STH-15SR Loud Speaker Only Gamewell-FCI P2RK Weatherproof Horn/Strobe – Wall Gamewell-FCI HPFF8 NAC Power Supply Battery Calculations E3 System Battery Calc HPFF8 Battery Calc CKT Voltage Drops Drawings Sheet No. Description Cover Page FA-C-01 Fire Alarm Cover Riser Diagram FA-R-01 Fire Alarm Riser and Matrix Building FA-1-01 Addressable Circuits Building FA-1-02 Notification Circuits E3 Series with LCD-SLP Display E3 Series with LCD-E3 Display E3 Series® Control Panel Expandable Emergency Evacuation System Analog and Networking Systems General The E3 Series® Expandable Emergency Evacuation System by Gamewell-FCI is in the forefront of the latest generation of fire alarm control panels. The E3 Series System is designed for use in virtually any application because it features a modular assembly that is configured per project requirements. Employing the new high-speed Velociti® sensors, the E3 Series provides previously unattainable polling speed and response together with the flexibility demanded by today’s emergency evacuation systems. In addition to the sensors’ high-speed polling rate, the Velociti Series of sensors feature bi-polar LEDs that flash green for normal polling, and light red steadily to indicate an alarm. The E3 Series is equipped with an 80-character LCD-E3 alphanumeric LCD display or 4.3” color touchscreen LCD-SLP display. Up to six keyboard LCD displays may be remotely located. In addition, you can install five of the familiar LCD-7100/RAN-7100 remote displays. The displays show instant system status information and can be connected in any desired area of an installation. FEATURES & BENEFITS • Styles 4, 6, or 7* signaling line circuits • IBC Seismic Certified • Listed under UL® Standard 864, 9th Edition • Listed under UL Standard UL2572 for Mass Notification • UL Listed for smoke control (dedicated and non-dedicated) when properly configured • UL Listed and FM Approved for Pre- action/Deluge and Agent Releasing • Two to 244 SLCs each supporting 159 sensors, 159 modules and 159 addressable sounder bases • 625K bits per second ARCNET communications using wire, fiber, or mixed configurations for installation flexibility • High-speed 32 bit processor and 8100 event history log • Advanced Boolean logic-based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming • Supports up to (16), ASM-16 addressable switch or ANU-48 LED driver modules per ILI- MB-E3/ILI95-MB-E3 •Two Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit •Integral city connection • Up to 9 levels of sensitivity adjustment • Flexible 115,200 baud high speed RS-232 interface • 40 character user- defined text per device •Supports the following: - 15 LCD-SLP displays/ annunciators - 6 LCD-E3 displays/ annunciators - 5 LCD-7100/RAN-7100 remote LED annunciators per ILI-MB-E3/ ILI95-MB-E3 • Polls 318 devices in less than two seconds • Activate up to 159 outputs in less than five seconds • LED’s blink associated device address during Walk Test. • Fully digital, high- precision protocol •Drift compensation • Pre-Alarm adjustable between 15 levels for both Alert and Action • Day/night automatic sensing adjustment •Sensitivity windows • Ion 0.05 - 2% obscuration • Photo 1 - 3% obscuration • Laser 0.02 - 2% obscuration • MCS Acclimate 2.5 - 4%, also self- adjustable options: 1- 2%, 2-3%, 3-4% •HARSH 1-3% obscuration • Each Loop Card has its own integral processor providing maximum survivability on loss of any other component. SLC provides full response on loss of any other system processor •Optional programmable switches can be configured to enable, disable or group any combination of output devices • Integrated point or Grouped Cross Zoning allows for numerous devices installed at any location to cooperate and determine alarm condition • Automatic detector sensitivity testing •Signals DIRTY and VERY DIRTY detector maintenance alerts 2 General A high-speed 32-bit processor can easily implement a wide array of applications used in small office buildings or used in multi-complex, high-rise installations. The 64 node networking is made possible by 625K bits per second ARCNET communications using twisted-pair copper cable, fiber-optic cable, or a combination of both. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. The basic E3 Series is equipped with the following modules: • PM-9 Power Supply • ASM-16 (Addressable Switch Module) • ILI-MB-E3/ILI95-MB-E3 (Intelligent Loop Interface-Main Board) • ILI-S-E3/ILI95-S-E3 (Intelligent Loop Interface- Expansion Board) • LCD-E3 (LCD Keypad Display) The ASM-16 features 16 software programmable switches, each accompanied by red, green and yellow LEDs that can be programmed to indicate the operation of the switches. Additional ASM-16 modules may be added to expand the operation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI- S-E3/ILI95-S-E3 provides the E3 Series control panel with two additional electrically isolated signaling line circuits. The layout is similar to the ILI-MB-E3/ILI95- MB-E3 with the exception that a number of components are omitted. It occupies one node on the Broadband network. Each ILI-MB-E3/ILI95-MB-E3 can support as many as sixteen ANU-48 LED Driver modules supporting hundreds of LEDs on a third party graphic annunciator to use for remote annunciation. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS-485 serial interface. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series Expandable Emergency Evacuation System offers four cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series cabinet assembly is a compact 19 3/8” (49 cm) wide, wall-mounted enclosure. • Cabinet A includes the following four options: - Cabinet A1 inner door mounted to the backbox. The backbox houses one NGA module. - Cabinet A2 inner door mounted to the backbox. The backbox houses one LCD-E3 module. - Two or three-bay inner door mounted to the backbox. - The backbox typically houses one LCD-E3, or one NGA, and one or two ASM-16 modules. • Cabinet B contains a space for the following modules installed inside the backbox: Additional module options mounted on the backbox include the following: The 2-bay inner door houses one LCD-E3 module and one ASM-16 module. • Both Cabinets C and D include the following: - Pre-assembled outer door that provides visibility to the fire fighter’s phone handset and a microphone voice messaging system. - Two inner door panel selections that may contain optional modules to meet the facility operation requirements. In the Cabinet B, C and D backboxes, the ANX appears in the same place as the ILI-MB-E3/ILI95-MB-E3 and PM-9/PM-9G. For information on the installation instructions for any of the E3 Series cabinets, refer to the E3 Series® Expandable Emergency Evacuation Manual, Part Number: LS10080-051GF-E. For other options including information on the system’s compatibility with the retrofit equipment, refer to the panel's installation manual, P/N:LS10080- 051GF-E or the Compatibility Addendum for Gamewell-FCI Manuals, P/N: 9000-0427-L8. Ordering Information ILI-MB-E3: Intelligent Loop Interface-Main Board ILI95-MB-E3: Intelligent Loop Interface-Main Board ILI-S-E3: Intelligent Loop Interface-Expansion Board ILI95-S-E3: Intelligent Loop Interface-Expansion Board ANX-SR: Addressable Node Expander-Single Ring ANX-MR-FO: Addressable Node Expander-Multi-Ring Fiber Optic ANX-MR-UTP: Addressable Node Expander-Multi- Ring Twisted-pair LCD-E3: LCD-E3, LCD Keypad Display LCD-SLP: LCD Color Touchscreen with five programmable switches RPT-E3-UTP: Network Repeater, unshielded, twisted- pair FML-E3: Multi-Mode Fiber-Optic Module FSL-E3: Single-Mode Fiber-Optic Module DACT-E3: Digital Alarm Communicator Transmitter ANU-48: ANU-48 LED Driver Module ASM-16: Addressable Switch Module NGA: LCD Network Graphic Annunciator PM-9: Power Supply Module, 120 VAC PM-9G: Power Supply Module, 220/240 VAC LCD-7100: Remote LCD Display RAN-7100: Remote LCD Display Note: For additional information on the cabinets, refer to the E3 Series Cabinets data sheet (Part Number: 9020-0649). - ILI-MB-E3 - PM-9 - ILI95-MB-E3 - PM-9G - ANX - DACT-E3 - ILI-S-E3 - ILI95-S-E3 - RPT-E3-UTP - E3 Series® Control Panel Technical Specifications 9020-0637 | S | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s E3 Series® Control Panel and other products available by visiting www.Gamewell-FCI.com Seismic Battery Bracket Kits For information on the types of Seismic Battery Bracket Kits that are available, the Seismic Battery Bracket Kit Part Numbers and the Installation Instructions, refer to the following documents: • Seismic Battery Bracket Installation Guide, P/N: 53839 • E3 Series Cabinets Data Sheet, P/N: 9020-0649 SYSTEM Operating Voltage: 24 VDC Operating Temperature: Not to exceed the range of 32°- 120° F (0 -49° C) Relative Humidity: Not to exceed 93%, non- condensing at 90° F (32° C) Primary Power Supply: 9 amps @ 55 AH capacity TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The E3 Series fire alarm control panel is designed to comply with the following standards: UL Standards UL 864 9th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterflow Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non-coded and Master Coded Operation UUKL for Smoke Control UL 2572 for Mass Notification Systems NFPA Standards NFPA 13 - Standard for Installation of Sprinkler Systems NFPA 16 - Standard for Foam-Water Sprinkler and Foam Water Spray Systems NFPA 72 - National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 NFPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist NFPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry Chemical/17A Wet Chemical Seismic Codes International Building Code IBC 2013 IBC 2009 IBC 2006 IBC 2003 IBC 2000 (Seismic) California Building Code CBC 2007 (Seismic) STANDARDS The E3 Series Control Panel is designed to comply with the following standards: UL Standards: UL 864 9th Edition UL 2572 for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1869, 2572 for Mass Notification FM: 3025415 MEA FDNY: 6175, COA #: 231-06-E CSFM: 7165-1703:0125 City of Chicago: Class 1, Class 2, High Rise City of Denver Approved The VMC Group, Reference Certificate of Compliance: VMA-45894-02C (Revision 1) ISO 9001 Certification GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0605 Rev. M page 1 of 2 ILI-E3 Series Intelligent Loop Interface-Main Board APPROVED FM 3025415S1869 SIGNALING City of Chicago Approved City of Denver ApprovedClass 1 Class 2 High Rise 7165-1703:0125 FDNY: COA # 231-06-E MEAApproved Description ILI-MB-E3The Intelligent Loop Interface-Main Board (ILI-MB-E3) is the main interface for the E3 Series® product line. With its state-of-the-art 32 bit RISC processor, this compact “panel on a board” provides a powerful addition to Gamewell- FCI’s single pair conductor solutions. The ILI-E3 Series is used in the following systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System This intuitive design provides the following features: • 2 signaling line circuits • auxiliary power output • local energy city box output • auxiliary relay functions • 2 notification application circuits These features, combined with the built-in network and the serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to the fire alarm panel design. The ILI-MB-E3 is network ready and occupies 1 of 64 nodes operating at 625K baud. In addition, the Address- able Node Expander (ANX) board expands the network to 122 nodes. When this sub-assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution. When the system trans- mits to remote locations, the optional RPT-E3 provides the ILI-MB-E3 with valuable signal boosting and transient pro- tection, as well as connectivity using both wire and fiber- optic cables. The ILI-MB-E3 provides 2 signaling line circuits and termi- nals for the connections to up to 159 detectors and 159 modules per SLC in Velociti®. In CLIP™ mode, each SLC supports 99 detectors and 98 modules. The RS-485 inter- face can support up to a total of 6 LCD-E3 modules, 16 ASM-16, and/or 16 ANU-48 remote LED driver modules. The ILI-MB-E3 relay outputs include system alarm, super- visory, and system trouble contacts. The ILI-MB-E3 pro- vides output for a local energy city master box or remote location which is non power-limited. All other wiring is Class 2 power-limited. CLIP™ is a trademark of System Sensor. E3 Series®, NetSOLO® and Velociti® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ILI-MB-E3 Features ILI-MB-E3 and ILI-S-E3: • Listed under UL ® Standard 864, 9th Edition.• Listed under UL Standard UL2572 for Mass Notification.• Network ready integral 625K baud ARCNET. • Supports 115.2K baud RS-232. • Provides signaling line circuits with the following: - Two Class A, Style 6, 7* or Class B, Style 4 circuits. - 40 Character user-defined text per device. - Capacity of 159 sensors and 159 addressable modules per circuit. • Includes 4100 Event History Log. *Style 7 wiring requires the use of the System Sensor M500X Isolator Modules. ILI-MB-E3 Only:• Two notification appliance circuits, Class “A”, Style Z or Class B, Style Y rated at 2.0 amps. per circuit. • RS-485 supporting 16 ASM-16 switch modules and/or ANU-48 LED driver modules. • Alarm, trouble, and supervisory dry contacts Form “C”, rated at 2 amp. @ 30 VDC (resistive). • Supports six local/remote LCD-E3 annunciators and five LCD-7100/RAN-7100 remote LED annunciators. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0605 Rev. M page 2 of 2 www.gamewell-fci.com ILI-S-E3 ILI-S-E3 The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 Series control panel with 2 additional sig- naling line circuits. The layout is similar to the ILI-MB-E3 except a number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. The ILI-S- E3 provides 2 signaling line circuits and terminals for the connections to up to 159 detectors and 159 modules per SLC in Velociti mode. In clip mode, each SLC supports 99 detectors and 98 modules. Installation Typically, the ILI-MB-E3 or ILI-S-E3 can be mounted in the following E3 Series cabinets: • Cabinet B and D, backbox • Cabinet B, B-Slim-E3 sub-assembly plate • Cabinet C, E3-ILI-C sub-assembly plate • Cabinet C, E3-INCC-C sub-assembly plate • Cabinet C, E3-INX-C sub-assembly plate • Cabinet D, E3-INCC-D sub-assembly plate • Cabinet D, E3-INX-D sub-assembly plate For instructions on the installation of the ILI-MB-E3 or ILI-S-E3, refer to the following documents: • E3 Series ® Expandable Emergency Evacuation Installation/Operation Manual, Part Number: 9000-0574 • ILI-MB-E3 Installation Instructions, Part Number: 9000-0579 • ILI-S-E3 Installation Instructions, Part Number: 9000-0569 For information on the ILI95-MB-E3 and ILI95-S-E3, refer to the ILI95-E3 Series Data Sheet, Part Number, 9021-60336. For information on the ANX, refer to the ANX Data Sheet, Part Number, 9021-60497. Specifications ILI-MB-E3 Operating Current:0.081 amp Alarm Current:0.150 amp max. ILI-S-E3 Operating Current:0.118 amp Alarm Current:0.119 amp ILI-MB-E3 and ILI-S-E3 Operating Voltage:24 VDC FWR (from the PM-9/ PM-9G Power Supply). Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%, non-condensing at 90° F (32° C) Supervised Class 2 Power-Limited SLC 40 Ohms maximum line impedance 0.5 µf maximum line capacitance Ordering Information Part Number Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0554 Rev. O page 1 of 1 ASM-16 ASM-16 Addressable Switch Module Rear View Front View APPROVED FM 3017416S1869 SIGNALING Approved City of Chicago Class 1 Class 2High Rise 7165-1703:01257170-1703:0126 FDNY: COA # 231-06-E MEAApproved City of Denver Approved Description •The Gamewell-FCI, ASM-16 Addressable Switch Module serves as the point of interface between an operator and the system’s audio evacuation, fire fighter intercom, and building control circuits. It is a component of the following systems: • E3 Series ® Expandable Emergency Evacuation System •E3 Series Combined Fire and Mass Notification System• E3 Series Broadband Voice Evacuation System • S3 Series (Small Addressable Fire Alarm Control Panel)•NetSOLO® System •The ASM-16 is a configurable switch input sub-assembly with 16 switches and 48 status LEDs. It may be remotely located via the RS-485 serial interface. Each ASM-16addressable switch module has 16 push-button switches that can be programmed to serve any function the applica- tion demands. •An ASM-16 switch can be programmed to operate as any of the following functions:• speaker circuit switch • fire fighter phone switch • auxiliary control switch (using a bank of two switches, one switch each for the on-off-auto functions). • switches with custom-defined functions: - system reset - system silence - system acknowledge- all-call, phone patch - lamp test, alarm tone on - manual select, etc. •Each ASM-16 switch also has three fully programmableLEDs that appear in red, yellow, and green. These LEDscan be programmed to work in concert with their associ-ated push-button switch or they can be programmed towork independently as status indicators (e.g. on, off, normal, etc.). •An INI-VGC, ILI-MB-E3/ILI95-MB-E3 or SLP (Smart LoopPanel) can accommodate up to 16 ASM-16 modules for atotal of 256 switches and 768 LEDs. •Specifications •Operating Voltage:24 VDC (nominal) (from the PM-9/PM-9G power supply)Operating Current:0.011 amp. (with no LEDs lit)Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93% (non-condensing) at 90° F (32° C) • E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL ® Standard UL2572 for Mass Notification. • Each INI-VGC supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each ILI-MB-E3/ILI95-MB-E3 supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each SLP supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each ASM-16 switch has 3 fully programmable status, indicating LEDS: red, yellow, and green. • All switch functions are fully software programmable. • Slip-in label inserts allow easily modified switch designations. Ordering Information Part Number Description 1100-0455 Programmable Addressable Switch Module GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0606 Rev. I page 1 of 1 LCD-E3 LCD Keypad Display APPROVED FM City of Chicago Approved City ofDenver Approved3025415Class 1Class 2 High Rise S1869 SIGNALING 7165-1703:0125 ApprovedMEA FDNY: COA #6077 Description The LCD-E3 provides the main panel display of the E3 Series® Expandable Emergency Evacuation System with indicating LEDs and operating switches. Up to six (6), LCD-E3 displays may be locally or remotely located from the panel via a local RS-485 bus of the E3 Series, ILI-MB- E3/ILI95-MB-E3 or the S3 Series, SLP (Smart Loop Panel) sub-assembly. The LCD-E3 includes an LCD display for the system status and the following switches and LED indicators: Switches • Alarm acknowledge • System reset/lamp test • Trouble acknowledge • Function buttons: - menu/back - back space/edit - OK • Signal silence • 12 button keypad LED Indicators • AC Power On (green) • Power Fault (yellow) • Alarm (red) • Ground Fault (yellow) • Supervisory (yellow) • System Silenced (yellow) • System Trouble (yellow) Installation Options The LCD-E3 is adaptable for installation in any of the following E3 Series System cabinets. Cabinet Part Number • “A” size cabinet, inner door E3ID2-A • “A2” flush cabinet E3BB-FLUSH-LCD • “A2” size cabinet, inner door E3ID-A2 • “B” size cabinet, inner door E3ID2-B • B-Slim cabinet, outer door E3BB-RBSLIM • 7200 B Retrofit, inner door 7200-B-RETROFIT • IF600 Retrofit, outer door IF600-RETROFIT • “C” size cabinet, inner door E3ID2-C • 600XL Retrofit, inner door 600XL-RETROFIT • 7200 C Retrofit, inner door 7200-C-RETROFIT • “D” size cabinet, inner door E3ID2-D Specifications Operating Voltage:24 VDC FWR (from PM-9 power supply) Operating Current:0.024 amp Alarm Current:0.028 amp Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%, non-condensing at 90° F (32° C) E3 Series® is a registered trademark of Honeywell International Inc. LCD-E3 Features •Listed under UL Standard 864, 9th Edition. • Provides an 80-character display of system events together with indicating LEDs and control switches. • The E3 Series, ILI-MB-E3/ILI95-MB-E3 or S3 Series, SLP can support up to six LCD-E3 displays, any or all of which may be remotely located via the RS-485 serial interface. • Offers a legible backlit LED display, with low power con- sumption. Ordering Information Part Number Description LCD-E3 LCD keypad display GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0555 Rev. O page 1 of 1 PM-9 PM-9 Power Supply S1869 Vol. 14 S1949 Vol. 19 APPROVED FM 3017416 7165-1703:0125 Approved City of DENVERApproved Class 1 Class 2 High Rise Chicago City ofSIGNALING FDNY: COA #6077 MEAApproved Description •The Gamewell-FCI, PM-9 Power Supply is a switching power supply that provides 9 amperes of filtered and regu- lated 24 VDC (nominal). It provides the power to the INX Transponder assembly and all of the E3 Series compo- nents. It is a component of the following systems. • E3 Series ® Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System • NetSOLO ® System •The PM-9 has an internal battery charging circuit capable of maintaining up to 55 A/H batteries. This module is designed for use with the Gamewell-FCI distributed audio networks. •Installation Typically, the PM-9 Module can be mounted in the follow- ing E3 Series cabinets: • Cabinet B and D, backbox • Cabinet C, INX-E3 sub-assembly plate • Cabinet C, INCC-E3 sub-assembly plate • Cabinet D, E3-INX-D Plate • Cabinet D, E3-ILI-D Plate •For information on the installation of the PM-9, refer to the following documents: • E3 Series Expandable Emergency Evacuation Installation/Operating Manual, P/N: 9000-0574 • PM-9 Installation Instructions, P/N: 9000-0548 • Mass Notification System Manual, P/N:LS10013-000GF-E •Specifications •Input Voltage:120 VAC 60 Hz @ 3.5 A. max. Output Voltage:24 VDC (nominal) FWR Output Current:9 amperes Output Current:1 ampere battery charging current Alarm Current:0.050 amp Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93% (non-condensing) at 90° F (32° C) Dimensions:10 1/2” W x 5” H x 2” D (27 x 13 x 5 cm) E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL Standard UL2572 for Mass Notification. • Includes 9 ampere, filtered, regulated power supply. • Provides 1 ampere battery charging current. • Offers energy and space saving switching technology. • Contains an integral battery charger capable of recharging up to 55 AH batteries. (Batteries not furnished). Ordering Information Part Number Description PM-9 Power supply 29229 AC Line Filter Kit PM-9 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2007 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0648 Rev. C1 page 1 of 2 INI-VG Series INI-VG Command Center Voice Gateway - Description The following sub-assemblies are components of the E3 Broadband Audio Evacuation System and optional com- ponents of the E3 Series™ Expandable Emergency Evac- uation System: •INI-VGC •INI-VGE •INI-VGX INI-VGC The INI-VGC Voice Gateway Module provides command and control functions for the INCC Command Center. The INCC serves as the point of interface between an operator and the system’s audio evacuation, fire fighter intercom, and building control circuits. A typical INCC assembly consists of an Intelligent Network Interface-Voice Gateway (INI-VGC) Module and one or more Addressable Switch Modules (ASM-16). Each INI- VGC can support up to sixteen (16), ANU-48 LED Driver Modules or ASM-16s for a total of 256 fully programmable switches and 768 LEDs (red, yellow, and green). The INI-VGC occupies a single node on the E3 Broad- band network and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INI-VGC-UTP is not equipped with fiber-optic connectors. The INCC Command Center’s INI-VGC module also pro- vides connections for an optional emergency voice page microphone as well as a Fire Fighter telephone handset. The INI-VGC is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technol- ogy to produce the clearest, most audible signal possible. The INI-VGC provides an output to a local speaker for message verification and testing. E3 Series™ is a trademark of Honeywell International Inc. Features The INI-VG Series include the following features: • Listed under UL Standard 864, 9th Edition. • All communication signals and control-by-event sequences over twisted, unshielded pair of wires or fiber-optic cable. • Distributed architecture, including Style 7 wiring configuration, allows system components to continue normal operation with NO loss of function during single line fault conditions. • Each INI-VGC or INI-VGE supports up to sixteen (16), ANU-48 LED drivers or ASM-16 switch modules for a total of 256 switches. • INI-VGC connects to a voice page microphone and fire fighter’s handset. • Redundant command centers with microphone and fire fighter’s handset easily configured by adding INCCs. • Advanced digital signal processor (DSP) technology for efficient audio compression and filtering. • Network data transfer rate at 625K baud. The INI-VGX includes the following features: • Software-programmable multi-channel digital audio applications. • One Style 4 signaling line circuit (SLC) supporting up to thirty-two (32), addressable speaker circuits. • AOM-MUXF for dual channel) and sixteen (16), addressable phone circuits (AOM-TELF). • Supports up to 150 watts of audio power (AM-50 amplifier modules) with additional 50 watts of standby in a single, compact wall- mounted cabinet. • 16 message capacity with up to 3 minute duration per INX and messages are easily field-configured via a laptop computer. SIGNALING S1869 3006578 APPROVED FM 7300-0694:231 Approved Class 1 Class 2 High Rise Chicago City of 255-02-E MEA Approved Approved City of DENVER An ISO 9000-2000 Company INI-VG GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0648 Rev. C1 page 2 of 2 www.gamewell-fci.com INI-VGC (Continued) The E3 Broadband Audio Evacuation System is a peer-to- peer, self regenerating, token ring network comprised of up to sixty-four (64), individual nodes. Each E3 Broadband node can be spaced on the network a maximum distance of 3,000 feet (914.4 m) or up to an 8dB loss using fiber-optic cable. Built-in isolation at each node permits Style 4, 6, and 7 net- work configurations. INI-VGE The INI-VGE Voice Gateway Module provides command and control functions for the INCC Command Center. It provides bulk amplification. A typical INCC assembly consists of an Intelligent Network Interface-Voice Gateway (INI-VGE) Module and one or more Addressable Switch Modules (ASM-16). Each INI- VGE can support up to six (6), ASM-16s for a total of 96 fully programmable switches and 288 LEDs (red, yellow, and green). The INI-VGE occupies a single node on the E3 Classic net- work and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INI-VGE-UTP is not equipped with fiber-optic con- nectors. The INCC Command Center’s INI-VGE Module also pro- vides connections for an optional emergency voice page microphone as well as a fire fighter telephone handset. The INI-VGE is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technology to produce the clearest, most audible signal possible. The INI-VGE provides an output capable of driving up to 20 Model AA-100 or AA-120 amplifiers. INI-VGX The INI-VGX Transponder Voice Gateway is a component of the E3 Broadband Audio Evacuation System and an optional component of the E3 Series Expandable Emer- gency Evacuation System. It is a multi-function module that incorporates: • Network interface using twisted, unshielded wire or fiber-optic cable. • Fully digital message generator. • One (1) signaling line circuit for local peripheral devices. • Local fire fighter phone riser. It occupies a single DIP switch selectable address on the network and provides termination points for the network connection using either a pair of twisted, non-shielded wire (12 AWG max.) fiber-optic cable, or a combination of the two. The INI-VGX-UTP is not equipped with fiber-optic con- nectors. The INI-VGX provides command and control for up to four (4), AM-50, 50 watt amplifiers in a single cabinet. The INI- VGX uses advanced Digital Signal Processing (DSP) tech- nology for audio compression and filtering allowing E3 Broadband to produce the clearest audio possible. Back- ground noise is automatically filtered during voice paging and fire fighter communications increasing audibility and eliminating the need for Push-to-Talk devices. Specifications INI-VGC, INI-VGE and INI-VGX Operating Voltage:24 VDC (nominal) Operating Current:0.150 amp. supervisory and alarm Operating Temperature:32° to 120° F (0 to 49° C) Relative Humidity:0 to 93% (non-condensing) Protocol:Asynchronous with half-duplex data flow Speed:RS-232 up to 64 KBps RS-485 up to 128 KBps St connectors*:Up to 200 microns (multimode), Optimized for 62.5/125 microns *St Connectors are omitted on the INI-VG-UTP Series. *Model INI-VGC only Ordering Information INI-VGC Model Description INI-VGC Command center voice gateway INI-VGC-UTP Command center—(unshielded twisted-pair only) INI-VGE INI-VGE Command center voice gateway INI-VGE-UTP Command center (unshielded twisted-pair only) INI-VGX INI-VGX Transponder voice gateway INI-VGX-UTP Transponder voice gateway (unshielded twisted-pair) GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2011 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60402 Rev. B page 1 of 1 INCC-MIC Paging Microphone ModuleDescription • The INCC-MIC Paging Microphone Module is a com- ponent of the NetSOLO® and E3 Series® fire alarm and voice evacuation systems. The INCC-MIC microphone provides a cost-effective microphone interface module for paging. Installed with the ASM-16 Addressable Switch Module, it pro- vides easy paging to selected speaker zones with visual indications of paging and zone status. Installation The INCC-MIC Paging Microphone Module can be installed in any of the following types of E3 Series cabinets: • Cabinet AA • Cabinet B • Cabinet C • Cabinet D Note: Gamewell-FCI recommends that you install the speakers at 4 ft. (1.2 m) or more from the microphone. Specifications INCC-MIC Paging Microphone Module Microphone Box Durable gauge steel construction with microphone holder Dimensions:5.5” W x 6.5” H x 2.75” D (14 W x 16.5 H x 7 D cm) E3 Series® is a registered trademark of Honeywell International Inc. Shure® is a registered trademark of Shure Incorporated. Features • Delivers audio feedback cancellation • Contains a supervised microphone • Provides status bit activation when the micro- phone is in use • Offers an easy installation • Has a preassembled microphone box with a microphone holder • Includes a terminal block with an easy-to-use plug-in cable Ordering Information Part Number Description 1100-0452 Paging Microphone Module INCC-MIC An ISO 9001-2000 Company ApprovedFDNY: COA-#6077 MEA GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2015 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0556 Rev. K1 page 1 of 2 AM-50 Series AM-50 Series Amplifiers SIGNALING S1869 Approved City of DENVER 3017416 APPROVED FM Approved Class 1 Class 2 High Rise Chicago City of FDNY: COA #6077 MEA Approved 7165-1703:0125 Description The Gamewell-FCI, AM-50 Series amplifiers are a 50 watt, digital, switching power amplifier. The following lists the 2 types of AM-50 Series amplifiers that may be ordered. • The AM-50-25 amplifier produces 25 VRMS audio output. • The AM-50-70 amplifier produces 70.7VRMS audio output. The amplifiers are components of the following E3 Series® Systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System WARNING: AM-50 Series Amplifiers Node Restriction: The INI-VGX can support up to 4 AM-50 Series amplifiers with the same output voltage. However, you cannot wire an AM-50-25 amplifier and an AM-50-70 amplifier to the same INI-VGX Voice Gateway Node. Each AM-50 Series amplifier provides 2 speaker circuits that can be wired Style Y (Class “B”) or Style Z (Class “A”). The terminal connections can accommodate up to 12 AWG, twisted-pair, shielded wire. Both speaker circuits pro- duce a combined total of 50 watts of power. The 50 watts of power can be divided between the 2 integral Class A/B speaker circuits. The 2 speaker circuits may be individually activated and supervised by an INI-VGX Transponder Voice Gateway. The AM-50 Series amplifier can be programmed to broad- cast 16 messages generated from its local INI-VGX Voice Gateway. In addition, the AM-50 Series amplifiers produce superior clarity for intelligible LIVE voice paging. When the selected System Sensor, SpectrAlert® Advance Series speakers are used with the Manufacturer’s 520 Hz audiophile, the E3 Series® System is compliant with UL Standard 464 Low Frequency requirements. For additional information, refer to the SpectrAlert Advance Series Data Sheet, P/N:9021-60346. Installation As many as four AM-50 Series amplifiers can be installed in the following cabinets when supervised and controlled by an INI-VGX Voice Gateway. • Cabinet B, INX CAB-B • Cabinet C, INX-CAB-C • Cabinet D, INX-CAB-D E3 Series® and SpectrAlert® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories, Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL Standard UL2572 for Mass Notification. • Complies with UL Standard 464 for 520 Hz Low Frequency. • Provides digital, switching amplifier technology. • Produces 50 watts of digital power. • Includes 2 speaker circuits, wired Style Y (Class B) or Style Z (Class A). • Up to 4 AM-50 Series amplifiers with the same out- put voltage can be controlled by the INI-VGX voice gateway. AM-50-25 AM-50-70 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0556 Rev. K1 page 2 of 2 www.gamewell-fci.com Description (Continued) The AM-50 Series amplifiers can be installed using the AM-50 Extender Plate whenever the E3 Series control panel is used in conjunction with the Autonomous Control Unit of the E3 Series Combined Fire and Mass Notification System. • Cabinet C, E3 INCC-CAB-C For additional information, refer to the E3 Series CombinedFire and Mass Notification Data Sheet, P/N:9021-60758 Specifications AM-50-25 Amplifier Operating Voltage:27.3 to 20.4 VDC Operating Current:0.086 amp normal standby Alarm Current:2.206 amp max. alarm @ 50 Watt Audio Output:50 watts max. @ 25 VRMS AM-50-70 Amplifier Operating Voltage:27.3 to 20.4 VDC Operating Current:0.049 amp normal standby Alarm Current:2.30 amp max. alarm @ 50 watt Audio Output:50 watts max. @ 70.7 VRMS AM-50 Series Amplifiers Relative Humidity:0 to 93% max., (non-con-densing) at 90° F (32° C) Operating Temperature:32° to 120° F (0° to 49° C) Dimensions:7 1/2” W x 3 1/2” H x 1 1/4” D (19 W x 9 H x 3 D cm) Ordering Information Part Number Description 1100-0456 AM-50-25, INX 25VRMS audio output, 50 watt amplifier AM-50-70 INX 70.7VRMS audio output, 50 watt amplifier ASD-PL2F/ASD-PTL2F ASD-PL2FR Velociti® Series 3 Detectors Photoelectric Detectors Addressable Devices Photoelectric Detector Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® Standard 268 7th Edition • Designed with a new profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by external magnet • Supports a low standby current • Provides rotary address switches (01-159) • Supplies optional relay, isolator, or sounder bases (standard or low frequency) • Includes dual LEDs for 360° visibility • Offers expanded color options 2 Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: “WH” suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: “IV” suffix indicates Flashscan and CLIP devices. “WH” suffix indicates bright white B501-WHITE: 4” Flangeless mounting base, bright white B501-WHITE-BP: 4” Flangeless mounting base bulk pack, bright white B501-IV: 4” Flangeless mounting base, ivory B300-6: 6” Flanged mounting base, bright white B300-6-IV: 6” Flanged mounting base, ivory B300-6-BP: 6” Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non-relay DNRW: Intelligent duct detector housing, non-relay, watertight Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6” Base, bright white TR300-IV: Accessory Flange Ring for B300 6” Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti® Series 3 Detectors Technical Specifications 9020-0617 | K | 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32° F to 122° F (0° C to 50° C) Photo in Duct Applications: -4° F to 158° F (-20° C to 70° C) Photo with Thermal: 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 10% to 93% non-condensing Rate-of-Rise Detection: Responds to greater than 15°F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 STANDARDS The Velociti® Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0624 Rev. E page 1 of 1 Velociti® Series AMM-4F Addressable Monitor Module 3023594APPROVED FM 7300-1703:0102 SIGNALING S1949 MEA Approved227-03-E Vol. IV Description The Gamewell-FCI Velociti® Series, addressable monitor module (AMM-4F) features a single Style D, Class A initiat- ing device circuit. It may also be configured as a Style B, Class B initiating circuit with end-of-line resistor. This mod- ule provides an address for any device or group of devices connected to this circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, linear heat detection devices, 4-wire projected beam smoke detectors, 4-wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in this circuit. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-4F module is designed for installation in the sig- naling line circuit of any Gamewell-FCI analog addressable control panel. The initiating circuit of the AMM-4F has a maximum line resistance of 40 ohms, allowing the module to accommodate a number of initiating devices at a dis- tance from the module. The AMM-4F is designed to mount in a 4” square junction box 2 1/8” deep. The initiating device circuit of the AMM-4F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. Ordering Information Model Description AMM-4F Addressable monitor module, single circuit, Style D, Class A or Style BC/A and B Velociti® and E3 Series® are registered trademarks of Honeywell International Inc. Features • Compact size allows easy installation • Class A, Style D, or Class B, Style B initiating circuit • Visual rotary, decimel switch addressing (01-159) • 40 ohm line resistance for each initiating device circuit • Accommodates any N/O dry contact device • Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm* *Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory current:.000375 amps. (LED flashing) Alarm current:.005 amps. (LED lit) Operating temperature: 32° to 120° F (0° to 49° C) Relative humidity:10 to 93% (non-condensing) End-of-line resistor:47K ohms Dimensions:4 1/2” H x 4” W x 1 1/4” D (11.4 x 10.2 x 3.2 cm) AMM-4F GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60475 Rev. E page 1 of 4 InnovairFlex™ Series DNR/DNRW Duct Smoke Housing Intelligent Non-Relay Photoelectric Duct Smoke Housing FM 3029700 APPROVED SIGNALING S911 MSFM 2202 2207 7272-1703:0121 S911 Description The InnovairFlex™ Series, DNR intelligent, non-relay pho- toelectric duct smoke detector, and the DNRW watertight, non-relay photoelectric duct smoke detector feature a piv- oting housing that fits both square and rectangular foot- prints. These detectors are capable of mounting to a round or rectangular duct. The DNR/DNRW detectors can be used with the E3 Series® and 7100 Series Systems. Note: The InnovairFlex™ Series, DNR requires the Veloc- iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays are required for the fan control. The DNRW duct smoke detector, with its NEMA 4 rating, is Listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water. These features allow operators to use the detector in the most extreme environments. The units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. A cover tam- per feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of the relay module. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. WARNING:Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building’s regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector 2911 application information. E3 Series® and Velociti® are registered trademarks and InnovairFlex™ is a trademark of Honeywell International, Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min to 4,000ft/min (0.5m/s to 20.32m/sec) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • New Cover tamper signal • Increased wiring space with a newly added 3/4-inch conduit knockout • Available space within housing to accommodate the mounting of the relay module • Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection •UL® 268A Listed • Remote testing capability • Requires SLC line power only • NEMA Type 4 UL Listed for non-hazardous indoor and outdoor applications (DNRW only) • UV Resistant, UL ® Listed housing and cover material (DNRW only) InnovairFlex-DNR/DNRW GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189021-60475 Rev. E page 2 of 4 www.gamewell-fci.com Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlex™ DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be UL Listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/min (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12–18 AWG wiring. Physical Specifications Size: Rectangular Dimensions:14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth Square Dimensions:7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight:1.6 lb (0.73 kg) Environmental Rating:NEMA4 (DNRW only) Operating Temperature Range:–4° to 158°F (–20° to 70°C) Storage Temperature Range:–22° to 158°F (–30° to 70°C) Operating Humidity Range:0% to 95% relative humidity non-condensing Air Duct Velocity:100 to 4000 ft/min (0.5 to 20.32 m/sec) DCOIL - (if included)17.5 - 26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the InnovairFlex DNR Duct Smoke Detector Installation Instructions, P/N I56-3051-001R. Accessory Current Loads at 24 VDC Device Standby Trouble RA100Z 0 mA 12 mA Max. RTS151/RTS151KEY 0 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). Figure 1 Figure 2 Figure 3 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 Wiring for Intelligent Non-Relay Duct Smoke Detector Figure 4 System Wiring Diagram for DNR Figure 5 DNR to RA100Z Figure 6 DNR to RTS151/RTS151 Key Important Notes: • The use of either RTS151 or RTS151KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N I56-3051-001R and the Duct Application Smoke Detectors Application Guide. • The RTS151/RTS151KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed. RA100Z RT151/RTS151KEY TEST COIL + TEST COIL - COMM + OUT (CONV ONLY) + COMM – RA/RTS – RA + RTS + RTS451/RTS451KEY RTS151/RTS151KEY RTS + RA + RA/RTS - COMM - OUT (CONV ONLY) + COMM + TEST COIL - TEST COIL + DNR TO RTS451/RTS451KEY/RTS151/ RTS151KEY WITH “R” REMOTE TEST CAPABLE DETECTOR HEAD OPTION: JUMPER 1 2 3 4 5 EXTERNAL(-) POWER (+)SUPPLY REMOTE TEST STATION LED OPTION 1 PER UNIT TEST COIL OPTION 1 PER UNIT95mA CURRENT DRAW GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189021-60475 Rev. E page 4 of 4 www.gamewell-fci.com Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are UL Listed. Figure 7 RTS151 UL S2522 Figure 8 RTS151KEY UL S2522 Figure 9 RA100Z UL S2522 Figure 10 ASD-PL2FR Ordering Information Part Number Description DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Part Number Description DCOIL Remove test coil required with RTS151/RTS151151KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH400OE-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1ft (0.3m) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes RA100Z/RA100ZA Remote annunciator alarm LED RTS151 Remote test station RTS151KEY Remote test station with key lock Agency Listings Multi-Voltage Conventional Relays System Sensor’s multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-10T/20T and R-14T/24T Removable front cover on steel enclosure for R-10E/R-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure’s cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware • • • • • • • • • • The R-10T, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-10T is a single FORM–C (SPDT) relay with a red activation LED, and the R-14T is a four-gang 1 FORM–C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM–C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM–C (DPDT) relay with four red activation LEDs. The R-10E/R-20E and R-14E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR–3 is identical to PR–2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0372-005 • 3/07 • #1782 Specifications: R-10T/R-14T/R-20T/R-24T Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10T/R-14T) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20T/R-24T) Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10% – 93% non-condensing Dimensions R-10T/R-20T: 2.5˝L × 3.35˝W × 1.2˝H R-14T/R-24T: 10˝L × 3.35˝W × 1.2˝H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Specifications: R-10E/R-14E/ R-20E/R-24E Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10E/R-14E) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10% – 93% non-condensing Dimensions R-10E/R-20E: 5.1˝L × 3.75˝W × 2.5˝H R-14E/R-24E: 11˝L × 5.3˝W × 2.5˝H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Multi-Voltage Conventional Relay Specifications PR–1 E0LR–1 PR–3 PR–2 R–10T R–14T R-10E & R-20E Enclosure R-14E & R-24E Enclosure Specifications: PR-1 Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 120 VAC Operating Current 15 mA DC max. @ 24 VDC, 24 VAC, 120 VAC Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Dimensions 0.87˝H × 2.01˝W × 1.42˝D Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive Specifications: PR-2/PR-3 Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Dimensions 0.91˝H × 1.65˝W × 1.22˝D Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Specifications: EOLR-1 Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature –22°F to 140°F (–30°C to 60°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30 VDC: 3 A max. (resistive load) GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60928 Rev. A page 1 of 4 Indoor Selectable-Output Strobes and Horn Strobes for Ceiling Applications L-SeriesIndoor Strobesand Horn Strobes APPROVED FM SIGNALING PENDING Description The L-Series audible visible notification products offer themost versatile and easy-to-use product line of horns,strobes, and horn strobes in the industry. This productincludes lower current draws and a modern aestheticdesign which reduce installation times and maximize prof-its. In addition, the L-Series offers white and red plastichousings and wall and ceiling mounting options. Similar to the entire L-Series product line, the ceiling-mount strobes and horn strobes include a variety of fea-tures that increase their application versatility while simpli-fying the installation. All devices offer a plug-in design sothat there is minimal intrusion into the backbox. These fea-tures make installations fast and foolproof while eliminatingcostly and time-consuming ground faults. To simplify the installation, the L-Series uses a universalmounting plate allowing you to mount the devices to a widearray of backboxes. With an on-board shorting spring,Installers can test wiring continuity before the device isinstalled. Installers can also easily adapt devices to suit a widerange of application requirements using the following:• Field-selectable candela settings.• Automatic selection of 12- or 24-volt operation.• Rotary switch for horn tones with two volume selections. L-Series Specifications Architect/Engineer Specifications General The L-Series ceiling-mount strobes and horn strobes shallmount to any of the following: • double-gang backbox • 4-inch octagon backbox • a standard 4 x 4 x 1 1/2-inch backbox Two-wire products shall also mount to a single-gang com-pact 2 x 4 x 17/8-inch backbox. A universal mounting plateshall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at theuniversal mounting plate. Also, the L-Series products, when used with the Sync•Cir-cuit Module accessory, shall be powered from a non-codednotification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync•Cir-cuit Module, the following occur: • 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Features • Listed for ceiling mounting only. • Features a plug-in design so that there is minimal intrusion into the backbox. • Designed with a tamper-resistant construction. • Provides an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Uses field-selectable candela settings on the following ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Produces horn rated at 88+ dBA at 16 volts. • Offers a rotary switch for horn tone and two volume selections. • Includes a universal mounting plate for ceiling units. • Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installa- tion. • Compatible with System Sensor synchronization protocol. • Supports electrical compatibility with the legacy SpectrAlert and the SpectrAlert Advance devices. Ceiling Horn Strobes GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118page 2 of 4 www.gamewell-fci.com 9021-60928 Rev. A UL Current Draw Table 1 lists the UL maximum strobe current draw. L-Series Specifications (Continued) Architect/Engineer Specifications (Continued) General (Continued) Ceiling strobes and horn strobes shall have the following field-selectable candela settings including: •15 •30 •75•95 •115 •150•177 StrobeThe strobe shall be an L-Series Model _______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe CombinationThe horn strobe shall be an L-Series Model _______ listed to UL Standard 1971 and UL Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize the L-Series strobes at 1 Hz and synchronize horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single-pair of wires. The module shall mount to a 4 11/6 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Standard Operating Temperature:32°F to 120°F (0°C to 49°C) Humidity Range:10 to 93% non-condensing Strobe Flash Rate:1 flash per second Nominal Voltage:Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2:8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3):8.5 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge:12 to 18 AWG Ceiling-Mount Dimensions (including lens):6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW):6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Table 1: UL Maximum Strobe Current Draw (mA RMS) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118www.gamewell-fci.com 9021-60928 Rev. A page 3 of 4 UL Current Draw Data Table 2 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes. Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. Candela 8 VDC 16 VDC 15 30 15 30 75 95 115 150 177 EM Temp Hi 103 167 71 90 143 165 187 217 254 EM Temp Low 96 165 54 71 137 161 185 211 249 EM Cont Hi 106 173 71 90 141 165 187 230 273 EM Cont Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 164 69 94 147 163 184 229 257 3.1K Temp Low 103 163 54 88 143 155 185 212 252 3.1K Cont Hi 111 172 69 94 144 164 202 220 271 3.1K Cont Low 103 169 54 88 131 155 187 217 259 16V FWR Candela 15 30 75 95 115 150 177 EM Temp Hi 107 135 179 198 223 254 286 EM Temp Low 78 101 151 172 199 229 262 EM Cont Hi 107 135 179 198 223 254 286 EM Cont Low 78 101 151 172 199 229 262 3.1K Temp Hi 108 135 179 200 225 255 289 3.1K Temp Low 79 101 150 171 196 229 260 3.1K Cont Hi 108 135 179 200 225 255 289 3.1K Cont Low 79 101 150 171 196 229 260 Table 2 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts FWR DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 Table 3: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118page 4 of 4 www.gamewell-fci.com 9021-60928 Rev. A SL Series Dimensions Figure 1 illustrates the dimensions for the ceiling-mount horn strobes. Figure 1 Ceiling-Mount Horn Strobes SL Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 2 Ceiling Backbox Surface-Mount Backbox L-Series Ordering Information Ceiling Horn Strobes Part Number Description PC2RL 2-Wire, Standard Horn Strobe, Red PC2WL 2-Wire, Standard Horn Strobe, White Ceiling Strobes SCRL Standard Strobe, Red SCWL Standard Strobe, White SCWL-CLR-ALERTStandard Strobe, White, ALERT Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60930 Rev. A page 1 of 3 Indoor Selectable-Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications L-Series Indoor Ceiling Speaker Strobes and Dual Speakers APPROVED FM SIGNALING PENDING Description The L-Series indoor selectable-output speaker strobes and dual-voltage evacuation speakers offer a modern, aes- thetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in ceiling applica- tions and its flexible design enables the Installer to easily perform the following: • Pre-wire mounting plates. • Dress the wires. • Confirm wiring continuity before the Installer plugs-in the speakers. In addition, this product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following: • The wiring is properly connected. • The rotary switches are set to the selected voltage and power settings. • The 7 field-selectable candela settings are configured for wall speaker strobes. The low total harmonic distortion of the SP speaker offers both high-fidelity and high-volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easy To install the L-Series speakers or speaker strobe, do thefollowing: 1. Attach a universal mounting plate to a 4 x 4 x 2 1/8 inch backbox. Flush-mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mount- ing plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch temporarily holds the device in place until you secure the device with a captured mounting screw. L-Series Speaker and Speaker StrobeSpecifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2 1/8-inch backbox. A universal mounting plateshall be used for the mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shallterminate at the universal mounting plate. Features • Includes a plug-in feature and protective cover to reduce ground faults. • Contains a universal mounting plate with an on-board shorting spring that is used to test the wiring continuity before an installation. • No extension ring required. • Field-selectable candela settings on ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Uses an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Provides a rotary switch that simplifies the field selection of speaker voltage (25) and 70.7 VRMS) and the follow- ing power settings: – 1/4 watt – 1/2 watt – 1 watt – 2 watts • Offers speakers with both high-fidelity and high-volume sound output. • Compatible with the System Sensor synchronization protocol. • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products. • Designed with a tamper-resistant construction. • Built with an updated modern design. Ceiling Speaker Strobes GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118page 2 of 3 www.gamewell-fci.com 9021-60930 Rev. A UL Current Draw Data Table 1 lists the UL maximum strobe current draw. Table 2 lists the ceiling mount speaker sound outputs. Table 3 lists the ceiling-mount speaker strobe sound out-puts. L-Series Speaker and Speaker Strobe Specifications (Continued) Architectural/Engineering Specifications (Continued) General (Continued) Also, the L-Series speaker strobes, when used with the Sync•Circuit. Module accessory, shall be powered from anon-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When these devicesare used with the Sync•Circuit Module, either of the follow- ing may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32° Fand 120°F from a regulated DC, or full-wave rectified, unfil- tered power supply. Speaker strobes shall have the follow-ing field-selectable candela settings: - 15 - 30 - 75 - 95 - 115- 150 - 177 SpeakerThe speaker shall be an L-Series model _______ dual- voltage transformer speaker capable of operating at 25.0or 70.7 nominal VRMS. It should be listed to UL Standard 1480 and shall be approved for fire protective service. Thespeaker shall have a frequency range of 400 to 4,000 Hzand shall have an operating temperature between 32°Fand 120°F. The speaker shall have power taps and voltagethat are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model__________ listed to UL Standard 1480 and UL Standard1971 and be approved for fire protective signaling sys-tems. The speaker shall be capable of operating at 25.0 or 70.7 nominal VRMS selected via rotary switch, and shallhave a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements forvisible signaling appliances, flashing at 1 Hz over thestrobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protectiveservice. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4 11/16 x 4 11/16 x 21/8-inch back box. The module shall also control two StyleY (Class B) circuits or one Style Z (Class A) circuit. Themodule shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will syn-chronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non-condensing Dimensions,Ceiling-Mount: Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Backbox6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Backbox 6.9 in, 176 mm 5.37 in,136 mm Electrical/Operating Specifications Nominal Voltage (speakers): 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers): 50 VDC Strobe Flash Rate: 1 flash per secondNominal Voltage (strobes): Regulated 12 VDC or Regulated 24 VDC/FWR Operating Voltage Range(includes fire alarm panelswith built-in sync): 8 to 17.5 V (12 V nominal) or16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal)or 16.5 to 33 V (24 V nominal) Frequency Range Frequency Range: 400 to 4,000 Hz Power: ¼, ½, 1, 2 watts Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Table 1: UL Max. Strobe Current Draw (mA RMS) Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Table 2: Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 3: Ceiling-Mount Speaker Strobe Sound Output GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60930 Rev. A page 3 of 3 Dimensions Figure 1 shows the speaker dimensions. Figure 2 shows the speaker dimensions. Surface Mounting Figure 3 illustrates the ceiling-mount speaker and speaker strobes with the SBBCR/SBBCWL surface mount back-box. Figure 1 Speaker Dimensions Figure 2 Speaker Dimensions Figure 3 Ceiling-Mount Speaker and Speaker Strobe with SBBCRL/SBBCWL Surface Mount Backbox L-Series Ordering Information SpectrAlert Speakers and Strobes Ceiling Mount Part Number Description SPCWL White Speaker only SPCRL Red Speaker only SPSCWL White Speaker Strobe SPSCRL Red Speaker Strobe SPSCWL-P Plain, Speaker Strobe SPSCWL-SP Fuego, Speaker Strobe SPSCWL-CLR-ALERT Alert, Speaker Strobe,Clear Lens Accessories SBBCWL White, Universal Ceiling Surface Mount Back Box SBBCRL Red, Universal Ceiling Surface Mount Back Box TRC-2W White, Universal Ceiling Trim Ring TRC-2 Red, Universal Ceiling Trim Ring GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2012 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com CS-2237 Rev. A page 1 of 1 STH-15S SUPERVISED LOUD Supervised Horn LoudspeakersDescription UL® is a registered trademark of Underwriter’s Laboratories Inc. The Series STH-15S supervised horn loudspeakers areequipped with a compression driver, providing up to 15Watt RMS power handling capability, superior intelligibility and dispersion to achieve maximum sound projection andpenetration. Weather-resistant metal construction and re-entrant acoustic path assure protection against water, humidity,vermin, and corrosion. The mounting bracket allows direc-tional sound dispersion via vertical and horizontal position-ing. Provisions are also included for surface or strap mounting to pillars and I-beams. All models include a built-in 25/70/100 V transformer. Thistransformer features a screw-driver adjustable, 7-position Watt/impedance selection switch. Wiring terminals are pro-tected with a vandal-resistant adapter cover for controlequipment using either cable or conduit. A built-in, 5 mfdcapacitor is provided on both models for line supervision. All models meet or exceed the UL® Listed standards foraudible signal appliances and are capable of operating within an ambient temperature range of 66°C (150°F) to -35°C (-30°F). Models comply with UL Standard 1480 — Speakers for Fire Protective Signaling Systems and Cali-fornia State Fire Marshal (Title 19). Engineer Specifications The supervised horn loudspeaker shall be a STH-15S/ STH-15SR. The horn shall be weather resistant and con-structed of heavy gauge, treated aluminum. The horn shall be able to operate within any ambient temperature envi-ronment ranging from 66o degrees C (150o F) to -35o degrees C (-30 F). The horn shall be a double re-entranttype with a 15 Watt RMS audio power rated compression driver producing a UL rated 102 dB measured at 15 wattsat 10 feet. The horn shall have an impedance selection via a 7 position switch of 5000, 2500, 1300, 666,333,89, and45. Power taps shall be available at 2.0, 4.0, 7.5, and 15 Watt for the 100 volt line, .9, 1.8, 3.8, 7.5, and 15 Watt forthe 70 volt line and .94, 1.8, 7.5, and 15 Watt for the 25 volt line. Each power tap shall have a 3 dB incremental rating. The frequency response range shall be 400 - 5000 Hz at 8ohms. The horn shall have a dispersion of 70o degrees. The horn assembly shall be furnished with a mountingbracket that allows adjustment on either a vertical or hori- zontal plane with a single locking pin and it includes provi-sions for mounting, banding or strapping. Wiring terminals shall be fully enclosed and a vandal-resistant adaptercover shall provide connection protection for cable or con- duit. The horn’s dimensions shall be 7.875”W x 8.75”H x9.313”D (200 x 222 x 237 mm). The horn shall be finished in grey (STH-15S) or red (STH-15SR) baked epoxy. Features STH-15S/STH-15SR • 15 Watt high efficiency compression driver • Re-entrant acoustic path • Weather resistant • Universal mounting • 25/70/100 V line matching transformer with a 7 position Watt/impedance selection switch Ordering Information Part Number Description 71768 15 watt-Horn Loud Speaker, Grey (STH-15S) 71769 15 watt-Horn Loud Speaker, Red (STH-15SR) An ISO 9001-2000 Company SIGNALING 464 Agency Listings Features • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Universal mounting plate for wall- and ceiling-mount units • Mounting plate shorting spring tests wiring continuity before devices are installed • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Rated from –40°F to 151°F • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from −40°F to 151°F. Like the entire SpectrAlert Advance product line, these devices include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes SpectrAlert® Advance outdoor selectable-output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes)7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) A05-0456-002 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB)5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions (SA-WBBC)7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0456-002 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output Data UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0456-002 • 11/09 • #2255 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2RK*†2-Wire Horn Strobe, Standard cd, Red, Outdoor P2RHK*†2-Wire Horn Strobe, High cd, Red, Outdoor P2WK*†2-Wire Horn Strobe, Standard cd, White, Outdoor P2WHK*†2-Wire Horn Strobe, High cd, White, Outdoor P4RK†4-Wire Horn Strobe, Standard cd, Red, Outdoor P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V Wall Strobes SRK*†Strobe, Standard cd, Red, Outdoor SRHK*†Strobe, High cd, Red, Outdoor SWK*†Strobe, Standard cd, White, Outdoor SWHK*†Strobe, High cd, White, Outdoor Model Description Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe, Standard cd, Red, Outdoor PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor PC2WK 2-Wire, Horn Strobe, Standard cd, White, Outdoor PC2WHK 2-Wire, Horn Strobe High cd, White, Outdoor PC4WK 4-Wire, Horn Strobe, Standard cd, White, Outdoor PC4WHK 4-Wire, Horn Strobe, High cd, White, Outdoor Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCWK Strobe, Standard cd, White, Outdoor SCWHK Strobe, High cd, White, Outdoor Horns HRK Horn, Red, Outdoor SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2RK-P. † Add “-R” to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝ Wall-mount horn strobes Ceiling-mount horn strobes 2.23˝5.05˝ 5.98˝ 7.1˝Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝Dia. 2.0˝ Wall weatherproof back box Ceiling weatherproof back box GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 HPFF8 NAC Expander/Power SupplyDescription The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field-programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper-Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- ing device signal inputs (for FACP trouble notification)- Earth ground faults by individual status LED's • Separate Trouble and AC Fail Form-C relay Contacts HPFF8 An ISO 9001-2000 Company 7315-1637:0102 SIGNALING S24562 FM APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189021-60521 Rev. B page 2 of 2 www.gamewell-fci.com Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi-pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power:120VAC/60Hz, 3.6A or 220VAC/50Hz, 1.5A Secondary Power:24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity:Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet:Up to two 18AH batteries SBB-D4 Cabinet:Up to two 12AH batteries per supply Total Output Power:8.0A max Standby Current: 0.030 A Auxiliary Power Output:0.15A under all conditions 2.0A if load is removed dur-ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (8.0A total) End-of-Line Resistor Range: 2K to 25k ohm, ½ watt Common Trouble Relay/AC Fail Relay:2.0A at 28VDC or 120VAC Input Control Circuit:16-30VDC @ 5mA min. Temperature Rating:32°F to 120°F (0°C to 49°C Relative Humidity:10% to 93% non-condensing Cabinet Dimensions: HPFF8 Cabinet:16.65” W x 19.0” H x 5.2” D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet:24” W x 45.9” H x 5.15” D (60.96 W x 116.52 H x 13.1D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black 0.780 A 5.106 A Qty Draw Standby Qty Draw Alarm 1 x 0.08100 0.08100 1 x 0.15000 0.15000 0 x 0.08100 0 x 0.15000 Intel. Loop Interface Main Board - Apollo (ILI95-MB-E3)0 x 0.05000 0 x 0.09100 Intel. Loop Interface Supplement Board - Apollo (ILI95-S-E3)0 x 0.05000 0 x 0.09100 E3 Panel, 1 SLC 0 x 0.05600 0 x 0.07600 E3 Panel, 1 SLC with DACT 0 x 0.07500 0 x 0.09500 1 x 0.06500 0.06500 1 x 0.08500 0.08500 0 x 0.08500 0 x 0.10500 120V Power Supply Sub-Assembly (PM-9)1 x 0.05000 0.05000 1 x 0.05000 0.05000 240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.05000 2 x 0.02400 0.04800 1 x 0.02800 0.02800 0 x 0.01300 0 x 0.01300 0 x 0.01800 0 x 0.01800 0 x 0.05000 0 x 0.07500 0 x 0.20000 0 x 0.20000 1 x 0.01100 0.01100 1 x 0.01100 0.01100 0 x 0.01100 0 x 0.01100 0 x 0.06500 0 x 0.06500 Intelligent Network Inferface Module (INI-7100)0 x 0.04000 0 x 0.04000 0 x 0.02000 0 x 0.020000x0.03500 0 x 0.20000 0 x 0.00100 0 x 0.001000x0.00100 0 x 0.00100 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 0 x 0.00100 0 x 0.00100 0 x 0.02000 0 x 0.020000x0.00200 0 x 0.00650 2 x 0.15000 0.30000 2 x 0.15000 0.300001x0.05000 0.05000 1 x 0.05000 0.05000240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.05000 2 x 0.08600 0.17200 2 x 2.20600 4.41200 Amplifier Sub-assembly, 50 watt 70V (AM-50-70)0 x 0.04900 0 x 2.30000 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 1 x 0.00100 0.00100 1 x 0.00100 0.00100 0 x 0.02000 0 x 0.02000 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 1 x 0.00020 0.00020 1 x 0.00200 0.00200 0 x 0.00020 0 x 0.00200 1 x 0.00020 0.00020 1 x 0.00200 0.00200 3 x 0.00038 0.00113 3 x 0.00500 0.01500 0 x 0.00038 0 x 0.00650 0 x 0.00030 0 x 0.00700 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1 1 Device AMM-4F/AMM-2F AOM-2RF/AOM-2SF MS-7AF 8. Notification Appliances Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) ASD-PL3 7. Smoke Detectors/Modules ATD-RL3 DNR Firefighter's Telephone (Handset) Addressable Output Module-Signal (AOM-2SF) Intel. Network Voice Gateway (INI-VGX) 120V Power Supply Sub-Assembly (PM-9) Class A Option Module (CAOM)Municipal Circuit Option Module (MCOM) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) Voice Paging Microphone (Microphone) Firefighter's Telephone (Handset) 3. 7100 Optional Modules Intel. Network Command Voice Gateway (INI-VGE) Addressable Switch Sub-assembly (ASM-16) Voice Paging Microphone (Microphone) Network LCD Annunicator (NGA) Auxiliary Switch Sub-Assembly (ASM-16) 4. INI-VGC Command Center Intel. Network Command Center (INI-VGC) 6. INI-VGE Command Center Voice Gateway Addressable Switch Sub-assembly (ASM-16) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Signal (AOM-2SF) 1. System Device E3 Panel, 2 SLC Amplifier Sub-assembly, 50 watt 25V (AM-50) 5. INI-VGX Voice Gateway LCD Display & Switch Control (LCD-E3) ARCNET Repeater (RPT-E3) Printer Transient Module (PTRM) Remote LED Driver Module (LDM-7100) Optional Remote Serial Annunicator (LCD-7100) Alarm CurrentStandby Current System Current Draw - FACP E3 Series Control Panel with Broadband Total AlarmTotal Standby Intel. Loop Interface, Main Board (ILI-MB-E3) Intel. Loop Interface Supplement Board (ILI-S-E3) Total Standby Load:0.780 A 5.106 ATotal Alarm Load: E3 Panel, 2 SLC with DACT 2. E3 Optional Modules Remote LED Driver Module (ANU-48) Addressable Node Expander (ANX) Digital Communicator (DACT-E3) Protected Premises:Date:6.7.2021 Address: City:State:ID Zip:83440 Prepared By:Phone:801-468-8300 Address:Email: City:State:Utah Zip:84115 Secondary Load Requirements 23.98 Amp Hours Total (AH) 18.71 1.28 19.99 x 1.20 23.98 AH 26.00 Amp Hours Battery Distribution Chart Spare Battery Capacity 2.02 Amp Hours Secondary Standby Load 22.45 Amp Hours Secondary Alarm Load 1.53 Amp Hours Current Draw Time (hours) Total Secondary Load from the calculation table below. Shows amp-hour distribution of your selections. Derating factor Secondary Load Requirements 26 AH Battery (12 volt) Required Alarm Time (hours) 0.250 hours Salt Lake City 24 hours Required Standby Time BYU-Idaho ETC Building Upgrade 525 South Center Street Rexburg Nelson Fire Systems System Power Requirements E3 Fire Alarm Control Panel with Broadband Battery Selection Secondary Standby Load 0.780 A Secondary Alarm Load 1481 S Major Street office@nelsonfire.com 5.106 A x x Select batteries from the list below. Total Secondary Load Spare Battery Capacity 8% Secondary Standby Load 86% Secondary Alarm Load 6%Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Standby 0.141 A Alarm 5.342 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 4 x 0.00000 0.00000 4 x 0.05400 0.21600 6 x 0.00000 0.00000 6 x 0.07100 0.42600 1 x 0.00000 0.00000 1 x 0.13700 0.13700 0 x 0.00000 0 x 0.23200 3 x 0.00000 0.00000 3 x 0.13700 0.41100 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.19000 23 x 0.00000 0.00000 23 x 0.05400 1.24200 1 x 0.00000 0.00000 1 x 0.07100 0.07100 0 x 0.00000 0 x 0.13700 0 x 0.00000 0 x 0.23200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.31300 2 x 0.00000 0.00000 2 x 0.05400 0.10800 1 x 0.00000 0.00000 1 x 0.07100 0.07100 2 x 0.00000 0.00000 2 x 0.13700 0.27400 1 x 0.00000 0.00000 1 x 0.16100 0.16100 1 x 0.00000 0.00000 1 x 0.23200 0.23200 2 x 0.00000 0.00000 2 x 0.13700 0.27400 1 x 0.00000 0.00000 1 x 0.23200 0.23200 1 x 0.00000 0.00000 1 x 0.06600 0.06600 0.00000 1.41800 1 x 0.00000 0.00000 1 x 0.05400 0.05400 0 x 0.00000 0 x 0.07100 1 x 0.00000 0.00000 1 x 0.13700 0.13700 4 x 0.00000 0.00000 4 x 0.23200 0.92800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.11900 1 x 0.00000 0.00000 1 x 0.03000 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.02000 0 x 0.04000 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.03000 1 x 0.06600 0.06600 1 x 0.06600 0.06600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 SCWL177 NAC #3 Totals (Max 3 Amps): SPSCWL177 4. L4 SPSCWL15 SPSCWL30 SPSCWL75 SPSCWL30 SPSCWL75 NAC #2 Totals (Max 3 Amps): Device SPSCWL15 SPSCWL75 5.342 System Current Draw - HPFF8 Total Current SPSCWL177 SPSCWL30 Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. L1 SCWL75 HPFF8 Main Circuit Board P2RK Other compatible devices Total Non-Alarm Load: SPSCWL177 2. L2 NAC #1 Totals (Max 3 Amps): SPSCWL30 SPSCWL75 NAC #4 Totals (Max 3 Amps): 3. L3 SPSCWL15 TB4 Totals (Max 2 Amps): SPSCWL95 SPSCWL177 SCWL75 SPSRK15 SPSCWL15 Other compatible devices 7. Compatible Devices not listed 0.141 6. Auxiliary Power PR-3 FIRERAY5000 CO1224TR E3SMRCO/E3SA Auxiliary Device Total Alarm Load: Protected Premises:Date:6.7.2021 Address: City:State:ID Zip:83440 Prepared By:Phone:801.468.8300 Address:Email: City:State:UT Zip:84115 Secondary Load Requirements 5.66 Amp Hours Total (AH) 3.38 1.34 4.72 x 1.2 5.66 AH 8 Amp Hours TRUE Current Draw Secondary Standby Load Select batteries from the list below. Battery Selection 8.0 AH BAT-1270 Battery (12 volt) Derating factor Secondary Load Requirements Total Secondary Load Secondary Alarm Load x5.342 A Required Alarm Time (hours) 0.250 hours Time (hours) Required Standby Time 24 hoursx Total Secondary Load from the calculation table below. 0.141 A 1481 S Major Street Office@nelsonfire.com Salt Lake City Secondary Power Requirements BYU-Idaho ETC Upgrade 525 South Center Street Rexburg Nelson Fire Systems HPFF8 Power Supply Page 2 of 131 Battery Distribution Chart Comments 2.34 4.06 1.60 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Spare Battery Capacity Secondary Standby Load 2. Selected battery size meets secondary load requirements. Battery Selection (AH) - Secondary Load Requirements (AH) Secondary Standby Load (AH) * Derating Factor 1. Batteries will fit in the FACP cabinet. Secondary Alarm Load (AH) * Derating FactorSecondary Alarm Load Shows amp-hour distribution of your selections. Spare Battery Capacity 29% Secondary Standby Load 51% Secondary Alarm Load 20% Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Page 3 of 131 Honeywell Online Tools For Fire Version 2.0.14 PROJECT DETAILS Project Name : BYU-Idaho Engineering Technology Center Upgrade Project Code : Project Location : 525 West Center Street, Rexburg, Idaho, 83440 PREPARED BY Nelson Fire Systems 1481 S Major St, Salt Lake City, Utah, 84115 Voltage Drop Calculations POWER SOURCE : FF8 New  MODEL NUMBER : HPFF8 BRAND : HPP CLASS B   20.4 VOLTS   DC POWER CIRCUIT: L1   3 Amps   14 AWG   14 DEVICES   32.87 % (0.986) AMPS USED 10.86 % (2.216) VOLTAGE DROP POWER SOURCE : FF8 New  MODEL NUMBER : HPFF8 BRAND : HPP CLASS B   20.4 VOLTS   DC POWER CIRCUIT: L2   3 Amps   14 AWG   24 DEVICES   33.53 % (1.006) AMPS USED 15.54 % (3.171) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SPSCWL 15 0.041 255 19.369 18.763 17.794 16.254 2 SPSCWL 15 0.041 20 19.291 18.640 17.598 15.942 3 SPSCWL 15 0.041 20 19.217 18.522 17.410 15.643 4 SPSCWL 15 0.041 20 19.146 18.409 17.231 15.358 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SCWL 75 0.111 170 19.726 19.331 18.697 17.691 2 SCWL 75 0.111 45 19.568 19.080 18.297 17.055 3 SCWL 75 0.111 45 19.430 18.861 17.948 16.499 4 SPSCWL 30 0.063 35 19.338 18.715 17.716 16.130 5 SPSCWL 30 0.063 35 19.255 18.583 17.506 15.796 6 SPSCWL 30 0.063 25 19.202 18.499 17.372 15.583 7 SPSCWL 30 0.063 25 19.155 18.425 17.254 15.396 8 SPSCWL 30 0.063 25 19.115 18.361 17.152 15.234 9 SPSCWL 30 0.063 25 19.081 18.307 17.066 15.097 10 SPSCWL 15 0.041 25 19.053 18.263 16.996 14.986 11 SPSCWL 15 0.041 20 19.034 18.233 16.948 14.910 12 SPSCWL 75 0.111 25 19.015 18.202 16.899 14.832 13 SPSCWL 15 0.041 25 19.007 18.189 16.878 14.799 14 SPSCWL 15 0.041 20 19.004 18.184 16.870 14.786 Voltage Drop 1.396 2.216 3.530 5.614 Page: 1 06/08/2021 15:37:08 PM POWER SOURCE : FF8 New  MODEL NUMBER : HPFF8   BRAND : HPP   CLASS B   20.4 VOLTS   DC POWER CIRCUIT: L3   3 Amps   14 AWG   11 DEVICES   40.53 % (1.216) AMPS USED   9.21 % (1.879) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SPSCWL 15 0.041 20 20.302 20.245 20.153 20.007 2 SPSCWL 15 0.041 35 20.137 19.983 19.735 19.342 3 SPSCWL 177 0.226 50 19.909 19.621 19.159 18.426 4 SPSCWL 30 0.063 35 19.781 19.418 18.836 17.912 5 SPSCWL 95 0.134 40 19.645 19.202 18.493 17.366 6 SPSCWL 75 0.111 40 19.531 19.021 18.204 16.906 7 SPSCWL 15 0.041 30 19.459 18.906 18.021 16.615 8 SPSCWL 75 0.111 45 19.358 18.746 17.765 16.208 9 SCWL 177 0.226 45 19.277 18.617 17.560 15.882 10 SCWL 75 0.111 50 19.232 18.546 17.447 15.703 11 SCWL 75 0.111 35 19.216 18.521 17.408 15.640 Voltage Drop 1.184 1.879 2.992 4.760 5 SPSCWL 15 0.041 20 19.078 18.302 17.060 15.086 6 SPSCWL 15 0.041 20 19.014 18.200 16.897 14.827 7 SPSCWL 15 0.041 20 18.953 18.103 16.743 14.581 8 SPSCWL 15 0.041 20 18.895 18.011 16.597 14.349 9 SPSCWL 15 0.041 30 18.813 17.881 16.390 14.020 10 SPSCWL 15 0.041 20 18.762 17.800 16.261 13.814 11 SPSCWL 15 0.041 20 18.714 17.724 16.140 13.621 12 SPSCWL 15 0.041 20 18.669 17.653 16.027 13.442 13 SPSCWL 15 0.041 20 18.628 17.587 15.923 13.276 14 SPSCWL 15 0.041 20 18.590 17.527 15.827 13.123 15 SPSCWL 30 0.063 20 18.555 17.472 15.739 12.983 16 SPSCWL 15 0.041 20 18.525 17.425 15.664 12.864 17 SPSCWL 15 0.041 20 18.499 17.383 15.597 12.758 18 SPSCWL 15 0.041 20 18.476 17.346 15.539 12.665 19 SPSCWL 15 0.041 25 18.451 17.307 15.477 12.566 20 SPSCWL 15 0.041 20 18.435 17.281 15.435 12.500 21 SPSCWL 15 0.041 20 18.422 17.260 15.402 12.447 22 SPSCWL 15 0.041 20 18.412 17.244 15.377 12.407 23 SPSCWL 15 0.041 20 18.405 17.234 15.360 12.380 24 SPSCWL 15 0.041 20 18.402 17.229 15.352 12.367 Voltage Drop 1.998 3.171 5.048 8.033 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG Page: 2 06/08/2021 15:37:08 PM POWER SOURCE : FF8 New  MODEL NUMBER : HPFF8   BRAND : HPP   CLASS B   20.4 VOLTS   DC POWER CIRCUIT: L4   3 Amps   14 AWG   6 DEVICES   33.97 % (1.019) AMPS USED   19.49 % (3.976) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SCWL 177 0.226 515 18.290 17.052 15.068 11.919 2 SCWL 177 0.226 50 18.131 16.799 14.665 11.278 3 SCWL 177 0.226 50 18.017 16.618 14.377 10.820 4 SPSCWL 75 0.111 50 17.948 16.509 14.204 10.544 5 SPSCWL 15 0.041 25 17.925 16.472 14.146 10.451 6 SCWL 150 0.189 40 17.895 16.424 14.069 10.329 Voltage Drop 2.505 3.976 6.331 10.071 Page: 3 06/08/2021 15:37:08 PM ENGINEERING TECHNOLOGY CENTER FIRE ALARM UPGRADE BRIGHAM YOUNG UNIVERSITY- IDAHO FIRE ALARM SYSTEM JPK XXXX TDT (ARCH C) 1/16" = 1' XXXX XXXX EN G I N E E R I N G T E C H N O L O G Y C E N T E R FI R E A L A R M U P G R A D E BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M PROJECT COVER SHEET FA-C-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: INDEX OF DRAWINGS PAGE 1 2 3 4 FA-C-01 FA-R-01 FA-1-01 FA-1-02 SHEET #LEVEL PROJECT COVER SHEET / INDEX OF DRAWINGS FIRE ALARM BUILDING RISER DIAGRAM / MATRIX BUILDING BUILDING DEVICE SCHEDULE COUNTS SMOKE DETECTOR w/BASE MONITOR MODULE SPEAKER/STROBE- CEILING ASD-PL3 w/B300-6 AMM-4F SPSCWL DESCRIPTION LOCAL OPERATING CONSOLE INCC-CAB FIRE ALARM CONTROL UNIT E3-BB-BC NAC SBB-C4 S MM SS FACU NAC C 4 SQ. 2-1/8" DEEP BOX MINIMUM w/3/O MUD RING 4 SQ. 2-1/8" DEEP BOX MINIMUM 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RING SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. PART NUMBER MOUNTING REQUIREMENTSYMBOL 1 3 10 1 44 1 10 1 1 44 1 STROBE ONLY- CEILING SCWLL 4 SQ. 2-1/8" DEEP BOX MINIMUM w/3/O MUD RINGC WEATHERPROOF SPEAKER/STROBE- WALL SPSRKSSWP SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. SHEET CONTENTS ADDRESSABLE CIRCUITS NOTIFICATION CIRCUITS SPEAKER ONLY- CEILING SPCWLSC 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RING LOC WEATHERPROOF HORN/STROBE- WALL P2RKHSWP SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. BYU-I ETC FA UPGRD COVER.DWG 5/25/2021 LOUD SPEAKER ONLY STH-15SRS 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RINGL MULTI-VOLTAGE RELAY PR-3R 4 SQ. 2-1/8" DEEP BOX MINIMUM DUCT DETECTOR w/SAMPLING TUBE DNR w/DST-5DD SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.1 1 FIRE 80" FLOOR LINE 96" 48" 60" MOUNTING HEIGHTS PULL STATION TOP AT 48" WALL NOTIFICATION DEVICE MAXIMUM 96" TO TOPMINIMUM 80" TO BOTTOM FACUTOP AT 72" REMOTE ANNUNCIATOR TOP AT 60" 72" 2 STRANDS SINGLE MODE FIBER OPTIC PER SYSTEM MANUFACTURER 2" CONDUIT WITH LONG RADIUS ELBOWS FIRE ALARM NETWORK CONNECTION TYPICAL ALL LOCATIONS 1 FIBER INTERCONNECT CONDUIT 2 STRANDS SINGLE MODE FIBER OPTIC PER SYSTEM MANUFACTURER 2" CONDUIT WITH LONG RADIUS ELBOWS FIRE ALARM NETWORK CONNECTION TYPICAL ALL LOCATIONS 1 FIBER INTERCONNECT CONDUIT BUILDING DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUIT JPK XXXX TDT (ARCH C) 1/16" = 1' XXXX XXXX EN G I N E E R I N G T E C H N O L O G Y C E N T E R FI R E A L A R M U P G R A D E BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O FI R E A L A R M R I S E R D I A G R A M 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M FIRE RISER DIAGRAM / MATRIX FA-R-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: BUILDING- SMOKE DETECTORS BUILDING- TAMPER SWITCH BUILDING- WATERFLOW SWITCH LOSS OF POWER ANY PANEL OR NAC LOW BATTERY CONDITIONS OPEN CIRCUIT CONDITIONS GROUND FAULTS FACP ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL REPORTING SYSTEM INPUTS SYSTEM OUTPUTSFIRE ALARM INPUT/OUTPUT MATRIX AL A R M S I G N A L T O F I R E A L A R M D I S P L A Y SU P E R V I S O R Y S I G N A L T O F I R E A L A R M D I S P L A Y TR O U B L E S I G N A L T O F I R E A L A R M D I S P L A Y BU I L D I N G S P E A K E R / S T R O B E S HV A C S H U T - D O W N FI R E / S M O K E D A M P E R S AL A R M S I G N A L T O M O N I T O R I N G C O M P A N Y SU P E R V I S O R Y S I G N A L T O M O N I T O R I N G C O M P A N Y TR O U B L E S I G N A L T O M O N I T O R I N G C O M P A N Y BYU-I ETC FA UPGRD RISER.DWG 5/25/2021 SS C SS CSSCSSCSSC SS C SS CSSCSSCSSC SS C S CSSCSSC SS C SS C SS C SS C SS C SS CSSC SS C SS C SS C SS C SS CSSC SS C SS C SS C SS CSSCSSCSSCSSCSSC SS C SS CSCSC SS C SS CSSCSCSSCSC S C S L L CSLLCLCSL L C S LLCSLLCSLLCSLSSCSSC L C S L L C S L L C S L SS WP 1WSP1-1 1WSP1-2 1WSP1-3 1/2WSP1-4 1/2WSP1-5 1/2WSP1-6 1/2WSP1-7 1/2WSP1-8 1/2WSP1-9 1 PAIR #14'S TWISTED SHIELDED SPEAKER CIRCUITL1-175cd L1-275cd L1-375cd L1-430cd L1-530cd L1-630cd L1-730cd L1-830cd L1-930cd 1/2W SP1-26 1/2W SP1-25 1/2W SP1-24 1/2W SP1-23 1/2W SP1-22 1/2W SP1-21 1/2W SP1-20 1/2W SP1-19 1/2W SP1-18 1/2W SP1-17 1/2W SP1-16 1/2W SP1-15 L2-11 15cd L2-10 15cd L2-9 15cd L2-8 15cd L2-7 15cd L2-6 15cd L2-5 15cd L2-4 15cd L2-3 15cd L2-2 15cd L2-1 15cd 4 #14'S (2) STROBE CIRCUITS 1/2WSP1-10 1/2WSP1-11 L1-1015cd L1-1115cd 1/2WSP1-12 L1-1275cd 1/2WSP1-13 L1-1315cd 1/2WSP1-14 L1-1415cd 1/2W SP1-31 1/2W SP1-30 1/2W SP1-29 1/2W SP1-28 1/2W SP1-27 L2-16 15cd L2-15 30cd L2-14 15cd L2-13 15cd L2-12 15cd 1/2W SP1-36 1/2W SP1-35 1/2W SP1-34 1/2W SP1-33 1/2W SP1-32 L2-21 15cd L2-20 15cd L2-19 15cd L2-18 15cd L2-17 15cd 1/2W SP1-38 1/2W SP1-37 L2-23 15cd L2-22 15cd SS C 1/2W SP1-39 L2-24 15cd 1WSP2-13 1WSP2-14 1WSP2-15 L3-1075cd L3-1175cd 1/2WSP2-9 1/2WSP2-10 1/2WSP2-11 1/2WSP2-12 L3-675cd L3-715cd L3-875cd L3-9177cd 1/2WSP2-4 1/2WSP2-5 1/2WSP2-6 1/2WSP2-7 1/2WSP2-8 L3-215cd L3-3177cd L3-430cd L3-595cd 1/2WSP2-2 1/2WSP2-31/2WSP2-1 L3-115cd 1 PAIR #14'S TWISTED SHIELDED SPEAKER CIRCUIT 4 #14'S (2) STROBE CIRCUITS1WSP2-18 1WSP2-17 L4-1177cd 1WSP2-22 1/2WSP2-21 1/2WSP2-20 L4-515cd L4-3177cdL4-6150cd 1/2WSP2-161WSP2-19 L4-475cd L4-2177cd FACU E3-BB-BC ASM-16 LCD-E3 PM-9 INI-VGX 4.5" DEEP19.375" WIDE 30" HIGH CONDUITS& ONE 3/4"TWO 1"(1) HP-FF8 5.2" DEEP24" WIDE 37.13" HIGH TRANSPONDER SBB-C4 w/FCI-DR-C4B (2) AM-50 2 #14'S WATER BELL CIRCUIT HS WP 1 PAIR #14'S TWISTED ADDRESSABLE CIRCUIT S MM TS 4 #14'S MM TS 4 #14'S MM WF 4 #14'S IN(-) (+) AD D R E S S A B L E C K T AMM-4F NO NCCOM FIELD DEVICE MONITOR MODULE (AMM-4F) CLASS 'A' CKT (+) (-)OUT(+) (-) SPCWL - CEILING SPEAKER ONLY TO NEXT DEVICESPEAKER CKT OUTIN ADDRESSABLE DETECTOR BASE 3 2(+)1(-) (+)(-) FR O M N A C P A N E L (+) (-) B300 AD D R E S S A B L E C K T OR P R E V I O U S D E V I C E TO N E X T D E V I C E SPRK - WEATHERPROOF SPEAKER TO NEXT DEVICESPEAKER CKT OUTIN SPSCWL - CEILING SPEAKER STROBE TO NEXT DEVICESPEAKER CKT OUTIN TO NEXT DEVICE(+) (-)STROBE CIRCUITIN OUT(+) (-) WEATHERPROOF WATERFLOW HORN/STROBE (P2RK) (+) (-) FROM NAC PANEL IN (+) (-)OUT STROBE CIRCUIT STH-15SR LOUD SPEAKER ONLY - WALL REMOVE INTERFACE 1 2 ADAPTER TO NEXT DEVICESPEAKER CKT OUTIN (+)(-) INCC-CAB LOCAL OPERATING CONSOLE 4.5" DEEP 19.375" WIDE 19.375" HIGH 1 PAIR #16'S TWISTED 1 PAIR #16'S TWISTED/SHIELDED 2 #14'S 1 PAIR #16'S TWISTED 1 PAIR #16'S TWISTED/SHIELDED 2 #14'S LOCATED IN CORRIDOR 131 INSTALL (2) STRANDS FIBER OPTIC SINGLE MODE FIBER WITH LC CONNECTORS (OPTIMIZED FOR 9 125 MICROMETER CABLE @1310 NM. UP TO 30 dB LOSS BETWEEN NODES) TO FACILITATE CONNECTION OF BUILDING CONTROL PANEL TO FIRE/EMERGENCY VOICE ALARM NETWORK. OUTGOING AND RETURN CIRCUITS SHALL BE PHYSICALLY SEPARATED AND INSTALLED IN SEPARATED CONDUIT/RACEWAY. 1 2 CONNCET TO EXISTING FIBER NETWORK 2 LOCATED ON LEVEL 0 E.O.L. 3.9K E.O.L. 4.7K E.O.L. 4.7K E.O.L. 3.9K L5-1 15cd 8.5" DEEP22" WIDE10" HIGH BCA BATTERY CABINET ILI-MB-E3 1 PAIR #14'S TWISTED ADDRESSABLE CIRCUITDDR 2 #14'S RELAY CIRCUIT DEVICE LEGEND S SMOKE DETECTOR TS TAMPER SWITCH WF WATERFLOW SWITCH SS SPEAKER/STROBE- CEILING LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC PANEL DESCRIPTIONCOUNTS L STROBE ONLY-CEILING SYMBOL 1 2 1 10 44 1 1 1 1 C SS WEATHERPROOF SPEAKER/STROBEWP S LOUD SPEAKER10 LOC L C INX VOICE PANEL1 1 HS WEATHERPROOF HORN/STROBEWP DD DUCT DETECTOR1 R RELAY1 E.O.L. 3.9K BUILDING- DUCT DETECTOR DNR - 2-WIRE DUCT SMOKE DETECTOR TO N E X T D E V I C E ADDRESSABLE CKT IN(-) (+)OUT(-) (+) JPK PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX EN G I N E E R I N G T E C H N O L O G Y C E N T E R FI R E A L A R M U P G R A D E BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M BUILDING ADDRESSABLE FA-1-01 SYSTEM NOTES: TO THE NAC PANEL LOCATED IN LEVEL 0 25'10'50' W E SN 1 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 801-468-8300 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "A" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. 11.WHERE LOCATED WITHIN SEVEN (7) FEET OF THE FLOOR, FIRE ALARM CABLES SHALL BE SECURELY FASTENED IN AN APPROVED MANNER AND PROTECTED FROM PHYSICAL DAMAGE. 12.DAMP OR WET LOCATION PROTECTION: BOXES, CONDUIT BODIES, OUTLET BOXES AND FITTING SHALL BE PLACED OR EQUIPPED TO PREVENT MOISTURE FROM ENTERING OR ACCUMULATING IN THEM AND SHALL BE LISTED FOR THAT USE. APPROVED DRAINAGE OPENINGS BETWEEN 18" AND 14" SHALL BE PERMITTED. 13.CLASS 'A' CIRCUITS USING PHYSICAL CONDUCTORS SHALL BE INSTALLED SO THAT THE OUTGOING AND RETURN ARE ROUTED SEPARATELY. MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 12" VERTICALLY AND 48" HORIZONTALLY. THE OUTGOING AND RETURN CIRCUIT CONDUCTORS SHALL BE PERMITTED IN THE SAME CABLE ASSEMBLY, ENCLOSURE, OR RACEWAY ONLY UNDER THE FOLLOWING CONDITIONS: 13.1.DISTANCE NOT TO EXCEED 10' WHERE THE OUTGOING AND RETURN CONDUCTORS ENTER OR EXIT THE DEVICE. 13.2..SINGLE DROPS INSTALLED IN A RACEWAY TO INDIVIDUAL DEVICES OR APPLIANCES. 13.3.IN A SINGLE ROOM NOT EXCEEDING 1000 SQ. FT., A DROP INSTALLED IN THE RACEWAY TO MULTIPLE DEVICES OR APPLIANCES THAT DOES NOT INCLUDE ANY EMERGENCY CONTROL FUNCTION DEVICES. 14.WHEN MORE THAN TWO VISUAL NOTIFICATION APPLIANCES ARE IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW, THEY SHALL BE SYNCHRONIZED. 15.CONTROL MODULE AND RELAY FUNCTION INTERFACES SHALL BE INSTALLED WITHIN 3 FEET OF THE POWER SOURCE TO OR THE DEVICE BEING CONTROLLED. 16.BUILDING CONSTRUCTION TYPE: IIB 16.1.MAINTAIN PATHWAY SURVIVABILITY LEVEL 0 GENERAL NOTES: BYU-I ETC FA UPGRD.DWG 5/25/2021 DEVICE LEGEND S SMOKE DETECTOR TS TAMPER SWITCH WF WATERFLOW SWITCH SS SPEAKER/STROBE- CEILING LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC PANEL DESCRIPTIONCOUNTS L STROBE ONLY-CEILING SYMBOL 1 2 1 1 1 1 C SS WEATHERPROOF SPEAKER/STROBEWP S LOUD SPEAKER LOC WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED B C WATER BELL CIRCUIT 2 #14'S D E SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED LOCAL OPERATING CONSOLE 1 PAIR #14'S TWISTED 1 PAIR #14'S TWISTED/SHIELDED 2 #14'S STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS ENGINES LAB 143 AUTO STORAGE 142 CE STORAGE 140 AUTOMOTIVE SHOP 138 HIGH BAY SHOP 137 CM / CE LAB 132 VESTIBULE 101 AUTO TOOL ROOM 138B BREAK ROOM 130 OFFICE 129 OFFICE 128 OFFICE 127 FIRE RISER 132B CURING CLOSET 137B CM/CE TOOL ROOM 132A STUDENTCOLLABORATION 136 CORRIDOR 139 I.T. 135 OFFICE 133 OFFICE 134 CUSTODIAL 138A MECH 141 WOMEN'S 117 MEN'S 115 JANITOR 116 OFFICE 121 OFFICE 124 OFFICE 122 OFFICE 123 OFFICE 119 OFFICE 120 OFFICE 125 CORRIDOR 118 CORRIDOR 131 SEATING 126 OFFICE (N.I.C.) 109 OFFICE (N.I.C.) 108 OFFICE (N.I.C.) 107 OFFICE (N.I.C.) 106 CONFRENCE ROOM (N.I.C.) 114 RECEPTION 102 OFFICE 104OFFICE (N.I.C.) 105 OFFICE 110 OPEN OFFICE 111 OFFICE 112 CORRIDOR 103 CONCRETE TOOLS 137A CM TOOL STORAGE 137C MECH 202 FACU S LOC WFTSTS 1 A L C INXNAC INX VOICE PANEL1 1 E LEVEL 2 LEVEL 0 LEVEL 1 1 E HS WEATHERPROOF HORN/STROBEWP DD R 1 A,F F RELAY CIRCUIT 2 #14'S REVISION NOTES: ADDED TO MEET CODE (5/25/2021)z Z RTU 8 DD DUCT DETECTOR1 R RELAY1 E.O.L. 3.9K JPK PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX EN G I N E E R I N G T E C H N O L O G Y C E N T E R FI R E A L A R M U P G R A D E BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M BUILDING NOTIFICATION FA-1-02 SYSTEM NOTES: TO THE NAC PANEL LOCATED IN LEVEL 0 25'10'50' W E SN 1 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 801-468-8300 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "A" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. 11.WHERE LOCATED WITHIN SEVEN (7) FEET OF THE FLOOR, FIRE ALARM CABLES SHALL BE SECURELY FASTENED IN AN APPROVED MANNER AND PROTECTED FROM PHYSICAL DAMAGE. 12.DAMP OR WET LOCATION PROTECTION: BOXES, CONDUIT BODIES, OUTLET BOXES AND FITTING SHALL BE PLACED OR EQUIPPED TO PREVENT MOISTURE FROM ENTERING OR ACCUMULATING IN THEM AND SHALL BE LISTED FOR THAT USE. APPROVED DRAINAGE OPENINGS BETWEEN 18" AND 14" SHALL BE PERMITTED. 13.CLASS 'A' CIRCUITS USING PHYSICAL CONDUCTORS SHALL BE INSTALLED SO THAT THE OUTGOING AND RETURN ARE ROUTED SEPARATELY. MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 12" VERTICALLY AND 48" HORIZONTALLY. THE OUTGOING AND RETURN CIRCUIT CONDUCTORS SHALL BE PERMITTED IN THE SAME CABLE ASSEMBLY, ENCLOSURE, OR RACEWAY ONLY UNDER THE FOLLOWING CONDITIONS: 13.1.DISTANCE NOT TO EXCEED 10' WHERE THE OUTGOING AND RETURN CONDUCTORS ENTER OR EXIT THE DEVICE. 13.2..SINGLE DROPS INSTALLED IN A RACEWAY TO INDIVIDUAL DEVICES OR APPLIANCES. 13.3.IN A SINGLE ROOM NOT EXCEEDING 1000 SQ. FT., A DROP INSTALLED IN THE RACEWAY TO MULTIPLE DEVICES OR APPLIANCES THAT DOES NOT INCLUDE ANY EMERGENCY CONTROL FUNCTION DEVICES. 14.WHEN MORE THAN TWO VISUAL NOTIFICATION APPLIANCES ARE IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW, THEY SHALL BE SYNCHRONIZED. 15.CONTROL MODULE AND RELAY FUNCTION INTERFACES SHALL BE INSTALLED WITHIN 3 FEET OF THE POWER SOURCE TO OR THE DEVICE BEING CONTROLLED. 16.BUILDING CONSTRUCTION TYPE: IIB 16.1.MAINTAIN PATHWAY SURVIVABILITY LEVEL 0 GENERAL NOTES: BYU-I ETC FA UPGRD.DWG 5/25/2021 DEVICE LEGEND S SMOKE DETECTOR TS TAMPER SWITCH WF WATERFLOW SWITCH SS SPEAKER/STROBE- CEILING LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC PANEL DESCRIPTIONCOUNTS L STROBE ONLY-CEILING SYMBOL 10 44 1 1 1 1 C SS WEATHERPROOF SPEAKER/STROBEWP S LOUD SPEAKER10 LOC WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED B C WATER BELL CIRCUIT 2 #14'S D E SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED LOCAL OPERATING CONSOLE 1 PAIR #14'S TWISTED 1 PAIR #14'S TWISTED/SHIELDED 2 #14'S STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS ENGINES LAB 143 AUTO STORAGE 142 CE STORAGE 140 AUTOMOTIVE SHOP 138 HIGH BAY SHOP 137 CM / CE LAB 132 VESTIBULE 101 AUTO TOOL ROOM 138B BREAK ROOM 130 OFFICE 129 OFFICE 128 OFFICE 127 FIRE RISER 132B CURING CLOSET 137B CM/CE TOOL ROOM 132A STUDENTCOLLABORATION 136 CORRIDOR 139 I.T. 135 OFFICE 133 OFFICE 134 CUSTODIAL 138A MECH 141 WOMEN'S 117 MEN'S 115 JANITOR 116 OFFICE 121 OFFICE 124 OFFICE 122 OFFICE 123 OFFICE 119 OFFICE 120 OFFICE 125 CORRIDOR 118 CORRIDOR 131 SEATING 126 OFFICE (N.I.C.) 109 OFFICE (N.I.C.) 108 OFFICE (N.I.C.) 107 OFFICE (N.I.C.) 106 CONFRENCE ROOM (N.I.C.) 114 RECEPTION 102 OFFICE 104OFFICE (N.I.C.) 105 OFFICE 110 OPEN OFFICE 111 OFFICE 112 CORRIDOR 103 CONCRETE TOOLS 137A CM TOOL STORAGE 137C MECH 202 FACU SS C LOC SS CSSCSSCSSC SS C SS C SS CSSC SS C SS CSC SS CSSCSSC SS C SS C SS C SS C SS C SS C SS C SS CSSC SS C SS C SS C SS C SS CSSCSSC SS C SS C SS C SS C SS C SS C SS C SS C S C S C SS C SS C SS C S C SS C S C S C S LLC S LLC L C S LLCSLLCSLLCSL L C S L SS CSSC L C S L L C S L L C S L SS WP 1 C,(2)D L1-175cd SP1-11W L1-275cd SP1-21W L1-375cd SP1-31W SP1-41/2WL1-430cd SP1-51/2WL1-530cd SP1-61/2WL1-630cd SP1-71/2WL1-730cd SP1-81/2WL1-830cd SP1-91/2WL1-930cd SP1-101/2WL1-1015cd SP1-111/2WL1-1115cd SP1-121/2WL1-1275cd SP1-131/2WL1-1315cd SP1-141/2WL1-1415cd SP1-151/2WL2-115cd SP1-161/2WL2-215cd SP1-171/2WL2-315cd SP1-181/2WL2-415cd SP1-191/2WL2-515cd SP1-201/2WL2-615cd SP1-211/2WL2-715cd SP1-221/2WL2-815cd SP1-231/2WL2-915cd SP1-241/2WL2-1015cd SP1-251/2WL2-1115cd SP1-261/2W SP1-271/2WL2-1215cd SP1-281/2WL2-1315cd SP1-291/2WL2-1415cd SP1-301/2WL2-1530cd SP1-311/2WL2-1615cd SP1-321/2WL2-1715cd SP1-331/2WL2-1815cd SP1-341/2WL2-1915cd SP1-351/2WL2-2015cd SP1-361/2WL2-2115cd SP1-371/2WL2-2215cd SP1-381/2WL2-2315cd SP1-391/2WL2-2415cd SP2-11/2WL3-115cd SP2-21/2W SP2-31/2W SP2-41/2WL3-215cd SP2-51/2WL3-3177cd SP2-61/2WL3-430cd SP2-71/2W SP2-81/2WL3-595cd SP2-91/2WL3-675cd SP2-101/2WL3-715cd SP2-111/2W SP2-121/2WL3-875cd L3-9177cd SP2-131/2W SP2-141W L3-1075cdSP2-151WL3-1175cdSP2-161/2W SP2-171W L4-1177cdSP2-181WL4-2177cdSP2-191WL4-3177cd SP2-201/2WL4-475cd SP2-211/2WL4-515cd SP2-221W L4-6150cd L C INXNAC INX VOICE PANEL1 LEVEL 2 LEVEL 0 LEVEL 1 HS WP 1 B 1 HS WEATHERPROOF HORN/STROBEWP E.O.L. 3.9KE.O.L. 4.7K E.O.L. 3.9K E.O.L. 3.9K E.O.L. 4.7K 1 C,(2)D E.O.L. 3.9K L5-115cd E.O.L. 4.7K F RELAY CIRCUIT 2 #14'S REVISION NOTES: ADDED TO MEET CODE (5/25/2021)z DD DUCT DETECTOR R RELAY