Loading...
HomeMy WebLinkAboutRes 2022-07 Attachement - Standard Drawings 2022 EditionREXBURGCITYOFAmerica's Family CommunityCITYOFREXBURG,IDAHOESTABLISHEDI883STANDARD DRAWINGS2022 EDITION ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILSTABLE OF CONTENTSTABLE OF CONTENTS4/4/20221 = 2NTS2PAGE NO. SHEET TITLE1 COVER SHEET2TABLE OF CONTENTS3ROAD CROSS SECTIONS 14ROAD CROSS SECTIONS 25UTILITY PLACEMENT6RESIDENTIAL CURB & GUTTER7COMMERCIAL CURB & GUTTER8TRENCH DETAILS9PEDESTRIAN EMPHASIS OVERLAY LIGHTING10STREET LIGHT STANDARD11SINGLE TRASH ENCLOSURE12DOUBLE TRASH ENCLOSURE13TRIPLE TRASH ENCLOSURE14QUADRUPLE TRASH ENCLOSURE1534" & 1" WATER METER DETAIL161 12" - 2" WATER METER DETAIL173" - 6" WATER METER DETAIL18INFILTRATOR DETAIL19BROADBAND NOTES20BROADBAND BOX AND COVER21BROADBAND ENTRY AND TRENCHTABLE OF CONTENTS ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILSSTREET CROSS SECTIONSDETAILS4/4/20221 = 2NTS3 SITE SPECIFIC(SITE SPECIFIC)12"X8" RIBBON CURB(TYP) BOTH SIDESScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILSSTREET CROSS SECTIONSDETAILS4/4/20221 = 2NTS4SITE SPECIFIC(SITE SPECIFIC)12"X8" RIBBON CURB(TYP) BOTH SIDES ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILUTILITY PLACEMENTUTILITY PLACEMENT4/4/20221:2NO SCALE5 ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY O FREXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSIDEWALK CURB & GUTTER DRIVEWAYRESIDENTIAL STANDARD DETAILSRESIDENTIAL4/4/20221 = 12NO SCALE6 Note: (Residential 4")ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY O FREXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSIDEWALK CURB & GUTTER DRIVEWAYCOMMERCIAL & MULTI-FAMILYSTANDARD DETAILSCOMMERCIAL4/4/20221 = 12NO SCALE7 NTSTRENCH DETAILAScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILFLOWABLE FILL TRENCH DETAILTRENCHING DETAILS4/4/20221:2NO SCALE8 ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGPEDESTRIAN EMPHASIS DISTRICT LIGHTINGSTREET LIGHTSSTANDARD DETAILSDETAILS4/4/2022NTS9VARIES (7' MIN)PROPERTY LINE8' WALK100' MAX SPACINGSTREET LIGHTLANDSCAPE STRIP8' WALKPROPERTY LINEEH22 FT 63LED 525MA 4K GCF R2 MVOLTANDB/EAE5-1 FINISH ANDB/ESPX-20-S5 FINISH ANDB ScalePlot ScaleDateDescriptionSheetFirm Name and AddressProject Name and AddressREXBURGCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 4/4/20221:24NONE10CITY OF REXBURGSTREET LIGHTELECTRICALSTA\NDARD DETAILS PLAN VIEWSCALE: 3/4" = 1'-0"1'-11"1'-11"10'-2"7'-0"SCHEDULE 40-4"Ø STEELBOLLARDS 4'-0" ABOVE GROUND3'-0" BELOW GROUND SET INCONCRETE (TYPICAL 3 PLACES)6" THICKCONCRETE PAD5'-4"1'-0"9'-2" MIN INSIDE DIMENSION6'-0" MIN INSIDE DIMENSION 6' HIGH SOLID PRIVACY FENCEMUST BE ATTACHED TOCONCRETE PAD AS APPROVEDBY CITY ENGINEER. PRIVACYMATERIALS INCLUDE: STONE,MASONRY BLOCK, WOOD,VINYL, OR CHAIN LINKFENCING WITH SLATS.SLOPE 1% MAX NOTES:Containers shall not be placed in an enclosure without proper inspection and approval ofby the City.Development dumpster guidelines: One dumpster/pickup per week for:1.for every 25 beds for dormitory housing2.for every 10 doors for 2-bedroom community housing3.for every 7 doors for 3-bedroom community housingEnclosure placement:1.a minimum of 30' distance from storm drain or drainage area2.not in right of way3.not located over/under utilities4.cannot obstruct the sight triangle5.if the enclosure has gates, they must be operable at a minimum of 180° and openedby tenantManeuvering area:1.All access areas shall be a minimum unobstructed width of 20 feet, 65 feet in lengthand 16 feet in height. The maximum deviation from the access path to the enclosureshall be 30˚. Outside turning radii in these areas shall be a minimum of 45 feet. At notime shall a collection vehicle be required to back while turning for more than 50 feetwhile on the property or be required to back out into or in from a public right-of-way.In such cases, a tee or circle turnaround that meets the minimum standards will berequired. In all cases, approach design should facilitate a looping or circleingress/egress path that avoids necessity of collection vehicle having to conductbacking maneuvers as much as possible.2.No parking will be allowed in the maneuvering area. Exemptions:The Solid Waste Manager or designee shall have authority to designate location, incircumstances where a dumpster and/or the screen that cannot be located upon a particular site, do to special circumstances and areas that are wholly impractical soas to conform with these requirements.ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY O F REXBURG,IDAHOESTABLISHEDI 8 8 3 11AS NOTED1 = 84/4/2022SINGLE TRASH ENCLOSURESINGLE TRASH ENCLOSURECITY OF REXBURG4'-514" PLAN VIEWSCALE: 1/2" = 1'-0"6'0" MIN INSIDE DIMENSIONS 16'-0" MIN INSIDE DIMENSION1'-11"1'-11"1'-6"ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY O F REXBURG,IDAHOESTABLISHEDI 8 8 3 12AS NOTED1 = 84/4/2022DOUBLE TRASH ENCLOSURETRASH ENCLOSURE CITY OF REXBURG17'-0"7'-0"6' HIGH SOLID PRIVACY FENCEMUST BE ATTACHED TO CONCRETE PADAS APPROVED BY CITY ENGINEER.PRIVACY MATERIALS INCLUDE: STONE,MASONRY BLOCK, WOOD, VINYL, ORCHAIN LINK FENCING WITH SLATS.SCHEDULE 40-4"Ø STEELBOLLARDS 4'-0" ABOVEGROUND 3'-0" BELOW GROUNDSET INCONCRETE (TYPICAL 4PLACES)6" THICKCONCRETE PADSLOPE 1% MAX5'-4"5'-4"1'-0"TYP NOTES:Containers shall not be placed in an enclosure withoutproper inspection and approval of by the City.Development dumpster guidelines: One dumpster/pickup per week for:1.for every 25 beds for dormitory housing2.for every 10 doors for 2-bedroom communityhousing3.for every 7 doors for 3-bedroom communityhousingEnclosure placement:1.a minimum of 30' distance from storm drain ordrainage area2.not in right of way3.not located over/under utilities4.cannot obstruct the sight triangle5.if the enclosure has gates, they must be operable at aminimum of 180° and opened by tenantManeuvering area:1.All access areas shall be a minimum unobstructedwidth of 20 feet, 65 feet in length and 16 feet inheight. The maximum deviation from the accesspath to the enclosure shall be 30˚. Outside turningradii in these areas shall be a minimum of 45 feet. Atno time shall a collection vehicle be required to backwhile turning for more than 50 feet while on theproperty or be required to back out into or in from apublic right-of-way. In such cases, a tee or circleturnaround that meets the minimum standards willbe required. In all cases, approach design shouldfacilitate a looping or circle ingress/egress path thatavoids necessity of collection vehicle having toconduct backing maneuvers as much as possible.2.No parking will be allowed in the maneuvering area. Exemptions:The Solid Waste Manager or designee shall have authorityto designate location, in circumstances where a dumpsterand/or the screen that cannot be located upon a particularsite, do to special circumstances and areas that are whollyimpractical so as to conform with these requirements.4'-514" PLAN VIEWSCALE: 12" = 1'-0"ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY O F REXBURG,IDAHOESTABLISHEDI 8 8 3 13NO SCALE1 = 124/4/2022TRIPLE TRASH ENCLOSURETRASH ENCLOSURE CITY OF REXBURG6' HIGH SOLID PRIVACY FENCEMUST BE ATTACHED TO CONCRETE PADAS APPROVED BY CITY ENGINEER.PRIVACY MATERIALS INCLUDE: STONE,MASONRY BLOCK, WOOD, VINYL, ORCHAIN LINK FENCING WITH SLATS.2'-0" CLEARNTS2'-0" CLEARNTS2'-0" CLEAR2'-0" CLEAR6'-0" MINIMUM INSIDE DIMENSION2" CLEARTYPICAL8" CLEARTYPICAL6" THICKCONCRETE PADSLOPE PAD 1% MAX 1'-0"TYP SCHEDULE 40-4"Ø STEEL BOLLARDS4'-0" ABOVE GROUND 3'-0" BELOWGROUND SET INCONCRETE (TYPICAL5 PLACES)NOTES:Containers shall not be placed in anenclosure without proper inspection andapproval of by the City.Development dumpster guidelines: One dumpster/pickup per week for:1.for every 25 beds for dormitoryhousing2.for every 10 doors for 2-bedroomcommunity housing3.for every 7 doors for 3-bedroomcommunity housingEnclosure placement:1.a minimum of 30' distance from stormdrain or drainage area2.not in right of way3.not located over/under utilities4.cannot obstruct the sight triangle5.if the enclosure has gates, they mustbe operable at a minimum of 180° andopened by tenantManeuvering area:1.All access areas shall be a minimumunobstructed width of 20 feet, 65 feetin length and 16 feet in height. Themaximum deviation from the accesspath to the enclosure shall be 30˚.Outside turning radii in these areasshall be a minimum of 45 feet. At notime shall a collection vehicle berequired to back while turning formore than 50 feet while on theproperty or be required to back outinto or in from a public right-of-way.In such cases, a tee or circleturnaround that meets the minimumstandards will be required. In allcases, approach design shouldfacilitate a looping or circleingress/egress path that avoidsnecessity of collection vehicle havingto conduct backing maneuvers asmuch as possible.2.No parking will be allowed in themaneuvering area. Exemptions:The Solid Waste Manager or designee shallhave authority to designate location, incircumstances where a dumpster and/or thescreen that cannot be located upon aparticular site, do to special circumstancesand areas that are wholly impractical so asto conform with these requirements.24'-0" MIN INSIDE DIMENSION5'-4"5'-4"5'-4"4'-514" PLAN VIEWSCALE: 38" = 1'-0"ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY O F REXBURG,IDAHOESTABLISHEDI 8 8 3 14NO SCALE1 = 164/4/2022QUADRUPLE TRASH ENCLOSURETRASH ENCLOSURE CITY OF REXBURG6' HIGH SOLID PRIVACY FENCEMUST BE ATTACHED TO CONCRETE PADAS APPROVED BY CITY ENGINEER.PRIVACY MATERIALS INCLUDE: STONE,MASONRY BLOCK, WOOD, VINYL, ORCHAIN LINK FENCING WITH SLATS.6" THICKCONCRETE PADSLOPE PAD 1% MAX2'-0" CLEAR2'-0" CLEARNTS2'-0" CLEAR2'-0" CLEAR6'-0" MINIMUM INSIDE DIMENSION2" CLEARTYPICAL8" CLEARTYPICALSCHEDULE 40-4"Ø STEEL BOLLARDS4'-0" ABOVE GROUND 3'-0" BELOWGROUND SET INCONCRETE (TYPICAL 6 PLACES)2'-0"CLEARNTS6'-0" MINIMUM INSIDE DIMENSION 2" CLEAR TYPICAL8" CLEARTYPICAL1'-0"TYPNOTES:Containers shall not be placed in anenclosure without proper inspection andapproval of by the City.Development dumpster guidelines: One dumpster/pickup per week for:1.for every 25 beds for dormitoryhousing2.for every 10 doors for 2-bedroomcommunity housing3.for every 7 doors for 3-bedroomcommunity housingEnclosure placement:1.a minimum of 30' distance from stormdrain or drainage area2.not in right of way3.not located over/under utilities4.cannot obstruct the sight triangle5.if the enclosure has gates, they mustbe operable at a minimum of 180° andopened by tenantManeuvering area:1.All access areas shall be a minimumunobstructed width of 20 feet, 65 feetin length and 16 feet in height. Themaximum deviation from the accesspath to the enclosure shall be 30˚.Outside turning radii in these areasshall be a minimum of 45 feet. At notime shall a collection vehicle berequired to back while turning formore than 50 feet while on theproperty or be required to back outinto or in from a public right-of-way.In such cases, a tee or circleturnaround that meets the minimumstandards will be required. In allcases, approach design shouldfacilitate a looping or circleingress/egress path that avoidsnecessity of collection vehicle havingto conduct backing maneuvers asmuch as possible.2.No parking will be allowed in themaneuvering area. Exemptions:The Solid Waste Manager or designee shallhave authority to designate location, incircumstances where a dumpster and/or thescreen that cannot be located upon aparticular site, do to special circumstancesand areas that are wholly impractical so asto conform with these requirements.32'-0" MIN INSIDE DIMENSION5'-4"5'-4"5'-4"5'-4"4'-514" LID & COVER TO FINISH GRADE3/4" & 1" WATER SERVICE CONNECTIONSCALE: NO SCALE1 GALVANIZED STAND PIPE 32 INCHES WRAPPED WITH DUCT TAPE OR APPROVED EQUAL.2 ALL SERVICE LINES SHALL BE BORED UNDER EXISTING ASPHALT PAVING. NO ASPHALT PAVING SHALL BE CUT FOR SERVICE LINE INSTALLATION UNLESS APPROVEDBY CITY ENGINEER.3 CITY TO SUPPLY PLUMBING PARTS AFTER CURB STOP TO ANGLE JUST AFTER METER CITY ALSO TO SUPPLY METER, LID, TOUCH READ, AND BARREL.4 WATER HOOK UP FEES MUST BE PAID BEFORE A METER AND REQUIRED PARTS ARE DELIVERED.5 METER BARREL MUST BE INSTALLED IN APPROVED AREA BY THE CITY OF REXBURG WATER DEPARTMENT.6 CURB STOP MUST BE EXPOSED SO IT CAN BE USED IF NECESSARY.7 COMPRESSION TYPE FITTINGS ARE REQUIRED. BARBED FITTINGS AND HOSE CLAMPS ARE NOT APPROVED FOR WATER LINES IN THE CITY OF REXBURG.8 ONLY THE WATER METER, CURB STOP AND SPRINKLER LINE CONNECTION ARE ALLOWED IN THE METER BARREL.9 SPRINKLER CONNECTION IS REQUIRED TO COME FROM INSIDE THE RESIDENCE OR IS REQUIRED TO BE INSTALLED ACCORDING TO THE ILLUSTRATION PROVIDED.(SEE DETAIL A)10 METER MUST BE INSTALLED WITHIN 15" TO 20" OF THE WATER METER LID.11 BEFORE COVERING ANY WATER SERVICE AN INSPECTION OF THE WATER METER AND SERVICE PIPING IS REQUIRED TO BE INSPECTED BY CITY INSPECTOR. COPPER JOINTS UNDER ASPHALT OR CONCRETE ARE REQUIRED TO BE BRAZED.12 FINAL OCCUPANCY WILL NOT BE GIVEN IF THE ABOVE REQUIREMENTS ARE NOT MET.13 METER TO MAIN No. 12 COPPER FINDER WIRE MIN. METER TO BUILDINGNo. 18 COPPER FINDER WIRE MIN. SEE SD-514 FOR SPLICINGGENERAL NOTES:4"FINISHED LAWN GRADE METERTOUCH READ BUTTONSERVICE LINEMETAL METER SUPPORT(6"- 8" UNDER METER)STRAP SERVICE LINETO METER SUPPORT2" MINBUILDING SIDEGALVANIZED PIPE,CONNECT TO METER& ANGLE METER VALVEW/APPROXIMATE FITTINGS20" X 48" POLY BARREL20" RING AND COVERW/ TOUCH READ HOLEBALL TYPE CORPORATION AND CURB STOPADAPTER, POLY-BY-FEMALE METAL PIPERATED AT 300 PSI MINIMUM WORKING PRESSURE.SPRINKLER CONNECTIONSUPPLIED BY OWNER(IF APPLICABLESEE DETAIL A)METER ANGLE STOPMETERMETER SLIP NUTBALL VALVESTO BUILDINGCURB STOP INSIDE METER BARREL(DO NOT COVER)WRAP PIPINGTO PREVENTCORROSIONDETAIL ACROSS SECTION OF METER(SEE NOTE #13)15"-20"TO SPRINKLER SYSTEMScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURG3/4 AND 1" WATER METER DETAILSTANDARD DETAILS3/4 & 1" METER DETAIL4/4/2022NTS15 FIRE LINERADIO READ WATER METERIN BUILDINGMAX 4'ABOVE FINISHED FLOORCULINARY WATER LINEVALVE (SEE NOTE 3)WATER LINETO WATER MAINBUILDINGDETAIL OF PIPE FOR INTERIOR METER INSTALLATIONSCALE: NO SCALEBALL VALVENIPPLESY STRAINERPROVIDED BY CITYCAST IRON FLANGES W/ GASKETS AND BOLTSPROVIDED BY CITYMETER PROVIDED BY CITYBALL VALVEPROVIDED BY CITYTO SYSTEM1-1/2" TO 2" INTERIOR METER DETAILSCALE: NO SCALENIPPLEGATE VALVEY STRAINERPROVIDED BY CITYMETER PROVIDED BY CITYGATE VALVE3" TO 8" INTERIOR METER DETAILSCALE: NO SCALENOTE: SUPPORT AS NECESSARYScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILS1 1/2" - 2" METER DETAIL1 1/2 - 2" METER DETAIL4/4/20221 = 2NTS16 ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGSTANDARD DETAILS3" - 6" METER DETAIL3 - 6" METER DETAIL4/4/20221 = 2NTS17FIRE LINERADIO READ WATER METERIN BUILDINGMAX 4'ABOVE FINISHED FLOORCULINARY WATER LINECULINARY GATE VALVEWATER LINETO WATER MAINBUILDINGDETAIL OF PIPE FOR INTERIOR METER INSTALLATIONSCALE: NO SCALEBALL VALVENIPPLESY STRAINERPROVIDED BY CITYCAST IRON FLANGES W/ GASKETS AND BOLTSPROVIDED BY CITYMETER PROVIDED BY CITYBALL VALVEPROVIDED BY CITYTO SYSTEM1-1/2" TO 2" INTERIOR METER DETAILSCALE: NO SCALENIPPLEGATE VALVEY STRAINERPROVIDED BY CITYMETER PROVIDED BY CITYGATE VALVE3" TO 8" INTERIOR METER DETAILSCALE: NO SCALENOTE: SUPPORT AS NECESSARY SEE DETAILCROSS SECTION INFILTRATOR DRAINSCALE 1/2" = 1'-0"PLAN VIEW DRAINSCALE 1/4" = 1'-0"CROSS SECTION VIEW DRAINSCALE 3/4" = 1'-0"ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 88 3 CITY OF REXBURGINFILTRATORSTANDARD DETAILSINFILTRATOR4/4/20221 = 1AS NOTED18 ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGBROADBAND DETAILSBROADBAND NOTESBROADBAND4/4/20221 = 2AS NOTED19GENERAL NOTES:1.DISTRIBUTION FIBER SHALL BE LOCATED WITHIN THE COMMUNICATION TRENCH AS SHOWN IN THE CITY OF REXBURG'S ENGINNERING STANDARDS.a.UNLESS OTHERWISE DETERMINED, FIBER CONDUIT MUST BE LAID ON BOTH SIDES OF THE STREET.DISTRIBUTION FIBER SHALL BE DIRECT BURY 4-WAY 18MM/14MM TRACEABLE DURA-LINE FUTUREPATH (OR EQUIVALENT).2.ALL DISTRIBUTION FIBER CONDUIT SHALL HAVE A LOCATE WIRE GROUNDED AT EACH HANDHOLE.3.MINIMUM DEPTH OF COVER OVER CONDUIT SHALL BE 36", UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.4.DISTRIBUTION BOXES AND/OR HANDHOLES SHALL BE PLACED:a.SINGLE FAMILY RESIDENCES: A 14" X 19" X 12" CARSON HDPE (OR EQUIVALENT) HANDHOLE SHALL BE PLACED IN BETWEEN SINGLE FAMILYRESIDENCES ON THE LOT LINE WITH THE INTENT TO SERVE TWO SINGLE FAMILY HOMES FROM EACH PULL BOX.b.SUBDIVISIONS: FOR MULTI-HOME DEVELOPMENTS, A 24" X 36" X 24" DURALITE ()OR EQUIVALENT) HANDHOLE SHALL BE PLACED AT THE CORNEROF THE EASEMENT.c.MULTIFAMILY RESIDENCES:i.DUPLEXES & FOURPLEXES: 24" X 36" X 24" DURALITE T22 (OR EQUIVALENT) HANDHOLE SHALL BE PLACED IN BETWEEN BUILDINGS WITH THEINTENT TO SERVE ALL THE RESIDENCES FROM THE HANDHOLE. FOR FOURPLEXES AND APARTMENTS THE BUILDER IS ENCOURAGED TO PLAN OUTTHE PATH OF THE DROP(S) AND INCLUDE A 2" PVC STUB-OUT FROM THE BUILDING TO A POINT THAT IS PAST SIDEWALKS, PATIOS, DRIVEWAYS,AND OTHER HARD SURFACES SO THE DROP CAN BE INSTALLED WITHOUT BORING OR CUTTING CONCRETE.ii.TOWN HOMES & 4 OR MORE APARTMENT BUILDINGS: A 24” X 36” X 24” T22 DURALITE (OR EQUIVALENT) HANDHOLE SHALL BE PLACED AT THECORNER OF THE LOT WHERE PRACTICAL.5.A 10' X 10' EASEMENT SHALL BE GRANTED TO THE CITY FOR ADDITIONAL FIBER INFRASTRUCTURE IF NEEDED. (HANDHOLES MAY BE WITHIN THIS AREA)6.FIBER CONDUIT SHALL BE STUBBED-OUT TO THE EDGES OF DEVELOPING PROPERTY TO ALLOW FOR FUTURE FIBER OPTIC SERVICE TO ADJACENTPROPERTY AND TO PROVIDE PATHWAYS TO THE OVERALL SYSTEM.a.ALL EMPTY CONDUITS SHOULD BE PLUGGED AS CONSTRUCTION TAKES PLACE.b.INDIVIDUAL HOUSE/BUSINESS FIBER SERVICE LINES SHALL BE LABELED AND STUBBED-OUT TO LOTS ADJACENT TO NEW STREETS TO ELIMINATETHE NEED FOR FUTURE EXCAVATION WORK IN NEW STREETS.6.DEVELOPERS SHALL BE RESPONSIBLE FOR INSTALLATION AND PURCHASE OF CONDUIT, DISTRIBUTION BOXES AND HANDHOLES FOR DIRECT BURY4-WAY DURALINE 18MM/14MM TRACEABLE FUTUREPATH (OR EQUIVALENT FOR THE PROPOSED NEW DEVELOPMENT.7.ACCEPTANCE OF THE FIBER CONDUIT ARE BASED IN THE FOLLOWING CRITERIA:a.BEDDING AND BACKFILLING OF TRENCHES SHALL BE CONSTRUCTED IN ACCORDANCE WITH CURRENT CITY STANDARDS OR OTHERWISE SPECIFIEDBY THE CITY ENGINEER.b.PERFORM ALL TESTING IN THE PRESENCE OF THE CITY ENGINEER OR HIS ASSIGNED AGENT.PLACEHOLDER FOR TESTING AND INSPECTION CHECKLIST ITEMS.c.A SIGNED "LETTER OF ACCEPTANCE" FROM THE CITY WILL BE REQUIRED PRIOR TO FINAL SURFACE RECONSTRUCTION. (I.E. :PAVING,LANDSCAPING, ETC.).8.THE DEVELOPER WILL CONSTRUCT, THE CITY WILL OWN, AND THE CITY'S THIRD-PARTY NETWORK ADMINISTER WILL OPERATE AND MAINTAIN, THEFACILITIES WITHIN THE EASEMENTS OR RIGHTS-OF-WAY. GRADETYPICAL 14" X 19" X 12" CARSON HDPE, OR24" X 36" X 24" T22 DURALITE HANDHOLE,OR EQUIVALENTGROUND ROD - ALL SPLICINGLOCATIONS - GROUND FOSCAND TRACE4" GRAVEL FILL AT HANDHOLE BASE4-WAY 18MM/14MM TRACEABLEDURA-LINE FUTUREPATH OR EQUIVALENTFOR STANDARD CONDUIT STUB INTOHANDHOLE WITH LARGE RADIUS BENDSTYPICAL HANDHOLE INSTALLNOT TO SCALEHANDHOLE ASSEMBLYSIZES (BOX AND COVER)DESCRIPTIONSIZE (LxWxH)CARSON HDPE14"X19"X14"DURALIGHTT2224"x36"x24"TYPICAL LID DETAILSNOT TO SCALETYPICAL HANDHOLE INSTALLATION NOT TO SCALEWH6"4"WHANDHOLE LID EVENWITH GROUND LEVELGROUND LEVELINSTALL 38" CRUSHED ROCK OREQUAL. EXTEND ROCK A MIN.OF 6" BEYOND WALLSXXX FIBERHH - 3 & HH - 4XXX FIBERXXX FIBER XXX FIBERHH - 1 & HH - 23/8"STAINLESSHEX BOLT"XXX" FIBERNAME PLATE38" OR 12"STAINLESSHEX BOLT*HANDHOLES SHALL BE NEW BASIS PRODUCTS OR EQUALALTERNATE AS APPROVED BY CITY ENGINEERScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGBROADBAND DETAILSBOX AND COVER DETAILSBROADBAND BOX 4/4/20221 = 2AS NOTED20 JOINT UTILITY4-WAY...CONDUIT ORAS SPECIFIEDFIELD BENDCONDUIT FORHANDHOLEENTRYTRENCH PATHWAY TOHANDHOLE LOCATIONJOINTTRENCHSHELF4 WAYCONDUIT ORAS SPECIFIEDFIELD BENDCONDUIT FORHANDHOLEENTRYNOTE:INSTALLATION CONTRACTOR TO FOLLOWMANUFACTURE'S SPECIFICATIONS FORCONDUIT AND HANDHOLE INSTALLATION.SEE MANUFACTURERS SPECIFICATIONSFOR MINIMUM CONDUIT BENDINGRADIUS.ScaleProject Name and AddressEXBURGRPlot ScaleDateDescriptionSheetFirm Name and AddressCITYOFAmerica's Family CommunityCITY OF REXBURG,IDAHOESTABLISHEDI 8 8 3 CITY OF REXBURGBROADBAND DETAILSENTRY AND TRENCH DETAILSDETAILS4/4/20221 = 2AS NOTED21