HomeMy WebLinkAboutSOIL DENSITY REPORT 2 - 22-00007 - 253 W 2nd S - Sundance Bldg CFile Name:
22-214D03292022LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D83E84AB-EE2A-45EA-B033-391FBE61E5C7 1
4103 E. 605 N. Suite. 1 Rigby ID, 83442 208.881.0081 www.connectengr.com
In Place Density of Soils ASTM D2922 & D3017
Project Number:
22-214
Contractor:
Bart Stevens
Project Name:
Sundance Apartments
Instrument ID
76562
Daily Standardization:
Client:
Bart Stevens
Date:
03/29/2022
MS:
689
DS:
2891
Time Start:
02:00 PM
Time End:
04:00 PM
Details
Test
#:
Location:Elevation: Depth:Wet:Dry:% M:Proctor #:%
Proctor:
Pass Fail
1 Game Room 5’ below
grade
12 137.1 131.4 4.4 137.1
Material
Type
Pit Run
96
2 Unit 3401 5’ below
grade
12 143.9 135.8 5.9 137.1
Material
Type
Pit Run
99
3 Unit 3402 5’ below
grade
12 142.6 135.2 5.4 137.1
Material
Type
Pit Run
99
4 Unit 3403 5’ below
grade
12 149.0 141.0 5.7 137.1
Material
Type
Pit Run
103
5 Unit 3404 5’ below
grade
12 140.3 133.8 4.9 137.1
Material
Type
Pit Run
98
6 Unit 3406 5’ below
grade
12 132.9 128.9 3.1 137.1
Material
Type
Pit Run
94
7 Unit 3406 5’ below 12 138.7 133.6 3.8 137.1 97
File Name:
22-214D03292022LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D83E84AB-EE2A-45EA-B033-391FBE61E5C7 2
Test
#:
Location:Elevation: Depth:Wet:Dry:% M:Proctor #:%
Proctor:
Pass Fail
grade Material
Type
Pit Run
8 In between 3408
and 3407
5’ below
grade
12 132.7 128.9 3.0 137.1
Material
Type
Pit Run
94
Observations/Remarks:
I arrived on site and located the prepped pit run. I began taking compaction tests. I recorded a total of 8 tests
and reported my results to the contractor. I then wrote this report.
Tested By:
Luke Hammar
Signature:
Reviewed By:
E. Vail
Signature:
Date:
04/04/2022
Inspection Images:
File Name:
22-214D03292022LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D83E84AB-EE2A-45EA-B033-391FBE61E5C7 3
File Name:
22-214D03292022LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D83E84AB-EE2A-45EA-B033-391FBE61E5C7 4