Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS REDLINED REVISIONS - 22-00024 - 64 S 3rd E - Solar Panels
Author Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Description : 64 S 3rd E - Solar PanelsAddress : 64 S 3rd EApplication Type : Document Filename : AVILA PERMIT PACKET.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments PV-2 Free text Larry Beesley : Building Open 2 3' pathway required by code because you are covering morethan 33% of this section of roof PV-2 Free text Larry Beesley : Building Open 2 Engineering of this roof is required . Pg 12 Free text Larry Beesley : Building Open 12 show the correct system for a metal roof. PV-3 Callout Alex Owens : Electrical Open 3 Where this is a supply side tap, the disconnect is considered aservice and therefore needs a neutral. The neutral also needsto be bonded to the grounding electrode conductor. PV-3 Callout Alex Owens : Electrical Open 3 Need verification that disconnect and soladeck junction boxare listed by an accredited laboratory. # 22-00024Solar Panels We need engineering for this roof. Report Date: 01.11.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) ADDITIONAL NOTES P L A N S E T L E G E N D S H E E T I N D E X V I C I N I T Y M A P A P P L I C A B L E C O D E S A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N 1.ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2.ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3.LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4.ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5.ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6.ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7.SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8.DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9.THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10.THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11.IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12.EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13.A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14.PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15.GFCI PROTECTION IN INVERTER.OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E PROJECT INFORMATION, VICINITY MAP ISSUED FOR: PERMIT DATE 12/17/2021 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM SARAH AVILA DESIGNED BY CONTRACTOR INFORMATION P V - 1 64, SOUTH 3RD EAST, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ ( E ) E X I S T I N G ( N ) N E W E X T E X T E R I O R I N T I N T E R I O R E M T E L E C T R I C A L M E T A L L I C T U B I N G R M T R I G I D M E T A L L I C T U B I N G F M C F L E X I B L E M E T A L L I C C O N D U I T V O C V O L T A G E O P E N C I R C U I T V M P V O L T A G E A T M A X . P O W E R I S C S H O R T C I R C U I T C U R R E N T I M P C U R R E N T A T M A X . P O W E R N T S N O T T O S C A L E MSPMTSACDCSLCMINVJBCBBAT M A I N S E R V I C E P A N E L M A N U A L T R A N S F E R S W I T C H A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X B A T T E R Y P V P R O D U C T I O N M E T E R R A P I D H U T D O W N D I S C O N N E C T PMRSD S A R A H A V I L A 6 4 S O U T H 3 R D E A S T , R E X B U R G , I D 8 3 4 4 0 1 0 - Q . P E A K D U O B L K M L - G 1 0 + 4 0 0 ( 4 0 0 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 3 8 0 0 H - U S ( 3 8 0 0 W ) I N V E R T E R S Y S T E M S I Z E : 4 . 0 0 0 K W D C S T C A R R A Y A R E A : 2 1 1 . 3 6 S F MTRMTSMSPACINV S C A L E : N T S TOTAL # OF PANELS:10ROOF TYPE:METAL A E R I A L V I E W S C A L E : N T S SITE PLAN, AERIAL VIEW N ISSUED FOR: PERMIT DATE 12/17/2021 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM SARAH AVILA DESIGNED BY CONTRACTOR INFORMATION P V - 2 64, SOUTH 3RD EAST, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ SITE PLAN A B B R E V I A T I O N S I N V I N V E R T E R M S P M A I N S E R V I C E P A N E L A C A C D I S C O N N E C T M T R M E T E R M T S M A N U A L T R A N S F E R S W I T C H S O U T H 3 R D E A S T R O O F D E S C R I P T I O N R O O F A R R A Y P I T C H A Z I M U T H # 1 3 0 ° 1 8 0 ° AC DISCONNECTWITHIN 3’ FROM UTILITY METER 3 ' P A T H W A Y 1 8 " C L E A R A N C E 1 8 " C L E A R A N C E ROOF #1 PATIO 3 ' p a t h w a y r e q u i r e d b y c o d e b e c a u s e y o u a r e c o v e r i n g m o r e t h a n 3 3 % o f t h i s s e c t i o n o f r o o f Engineering of this roof is r e q u i r e d . ELECTRICAL SINGLE LINE DIAGRAM 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N 2 9 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) ( B ) E L E C T R I C A L N O T E S S C A L E : N T S SINGLE LINE DIAGRAM R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) ISSUED FOR: PERMIT DATE 12/17/2021 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM SARAH AVILA DESIGNED BY CONTRACTOR INFORMATION P V - 3 64, SOUTH 3RD EAST, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . M O D U L E : Q . P E A K D U O B L K M L - G 1 0 + 4 0 0 ( 4 0 0 W ) V o c = 4 5 . 3 0 V I s c = 1 1 . 1 4 A V m p = 3 7 . 1 3 V I m p = 1 0 . 7 7 A ELECTRICAL E Q U I P M E N T C A L L O U T S 4,000W TOTAL SOLAR ARRAY10 Q.PEAK DUO BLK ML-G10+ 400 (400W) PANELSWIRE AND CONDUIT CALLOUTS SOLADECK M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/ROOF P E N E T R A T I O N , 6 0 0 V 3.8kW INVER T E R U N G R O U N D E D SOLAREDGE S E 3 8 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 240VAC, 16A , N E M A 3 R , U L L I S T E D , (W/ INTEGRA T E D D C D I S C O N N E C T ) WITH INTEG R A T E D G F P , W / I N T E G R A T E D A F P (2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC SOLAREDGE P 4 0 1 O P T I M I Z E R O N E P E R P A N E L BI-DIRECTIO N A L U T I L I T Y M E T E R ABCDEFSQUARE D S A F E T Y S W I T C H , # H 2 2 1 N R B 250 VAC, 30 A , N E M A 3 R , F U S E D , U L , N E M A , CSA, NOM C E R T I F I E D W / 2 0 A F U S E S 123150A (E) MAI N S E R V I C E P A N E L (W/ 150A MAI N B R E A K E R T O P F E D ) 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS 4(2) #6 AWG THWN-2(1) #8 AWG THWN-2 GND IN 3/4" EMTL1L2NGDL1L2NG4 _ ~ M P P T 1 M P P T 2 3 C 1 STRING OF 10 MODULES CONNECTED IN SERIES @ INVERTER 1 0 M O D U L E S I N S E R I E S 1 B A O N E P E R P A N E L 2 S T R I N G 1 TAP 27AC DISCONNECTWITHIN 3’ FROM UTILITY METER (2) #12 AWG THWN-2(1) #12 AWG THWN-2 GND IN 3/4" EMTFNGGENERATOR150AENGG200A MANUA L T R A N S F E R S W I T C H , NEMA 3R, UL L I S T E D , GWhere this is a su p p l y s i d e t a p , t h e disconnect is consi d e r e d a s e r v i c e and therefore need s a n e u t r a l . T h e neutral also needs t o b e b o n d e d t o the grounding elec t r o d e c o n d u c t o r . N e e d v e r i f i c a t i o n t h a t d i s c o n n e c t a n d s o l a d e c k j u n c t i o n b o x a r e l i s t e d b y a n a c c r e d i t e d l a b o r a t o r y . REQUIRED SIGNAGE ISSUED FOR: PERMIT DATE 12/17/2021 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM SARAH AVILA DESIGNED BY CONTRACTOR INFORMATION P V - 4 64, SOUTH 3RD EAST, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ REQUIRED SIGNAGE 2. LABEL FOR SOLAR AC DISCONNECT: S Y S T E M A C V O L T A G E : 2 4 0 V T O T A L R A T E D A C A M P S : 2 0 A S Y S T E M A C V O L T A G E : 2 4 0 V 3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECT D I R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M A C V O L T A G E : 2 4 0 V M A X A C C I R C U I T C U R R E N T : 1 6 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A 8. T H E F O L L O W I N G S I G N M U S T B E P R O V I D E D O N T H E O U T S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E P A N E L B O A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:10. S I G N A G E R E Q U I R E D A T S T R I N G I N V E R T E R P E R N E C 6 9 0 . 5 3 : 9. S I G N A G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 7. A T P V D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 6. R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : "SOLAR AC DISCONNECT"WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE.WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEM IN V E R T E R S www.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 AUtility Monitoring, Islanding Protection, C o u nt r y C o nfi g u ra b l e T h re s h o l d s Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 WADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety solaredge.com P O W E R O P T I M I Z E R Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cellmodules) P370 (for higher- power 60 and 72- cell modules) P400 (for 72 & 96-cellmodules) P401 (for high power 60 and 72 cell modules) P405 (for high- voltage modules) P485 (for high- voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1) 320 350 370 400 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 125(2) 83(2) Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 11.02 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 / 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3) Single or dual MC4(3)(4) MC4(3) Input Wire Length 0.16 / 0.52 0.16 or 0.9 /0.52 or 2.95(5) 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(6) -40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1)Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power ”. Modules with up to +5% power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V (3)For other connector types please contact SolarEdge (4)For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals(5)Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx(6)For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter(7)(8) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P320, P340, P370, P400, P401 8 10 18 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50(9) Maximum Power per String 5700 (6000 with SE7600-US - SE11400- US) 5250 6000(10) 12750(11) W Parallel Strings of Different Lengths or Orientations Yes (7) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (8) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (9) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (10) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (11) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2021 DS-000044-1.2-NA. Subject to change without notice. 405 MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL show the correct system for a m e t a l r o o f . MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL