Loading...
HomeMy WebLinkAboutPLANS - 22-00210 - BYUI Manwaring Welcome Center - Remodel3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 G000 COVER SHEET [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set BYUI MANWARING WELCOME CENTER REMODEL Bid Set - March 25, 2022 owner byu-idaho 525 s center st. rexburg, id 83460 (208) 569-2623 contact: neihlee muir architect method studio 360 w aspen ave salt lake city, ut 84101 (801) 532-4422 contact: kyler hokanson structural tbse structural engineers 233 north 1250 west #201 centerville, ut 84014 (801) 698-1806 contact: donald barfuss mechanical heath engineering company 377 w 800 n salt lake city, ut 84103 (801) 322-0487 contact: andy paskett electrical payne engineering 1823 e. center pocatello, id 83201 (208) 232-4439 contact: todd payne MATERIAL LEGEND EARTH (EXISTING) EARTH (BACKFILL) DRAINAGE FILL COMPACTED FILL CONCRETE CAST-IN-PLACE CONCRETE PRECAST BRICK CONCRETE MASONRY UNIT GROUT STEEL ALUMINUM CONTINUOUS WOOD SHEATHING INTERMITTENT WOOD BLOCKING WOOD FINISH HARDBOARD PARTICLE BOARD BATT INSULATION LOOSE FILL INSULATION RIGID INSULATION FIRE SPRAY GYPSUM BOARD ARCHITECTURE SYMBOLS A102 SHEET TYPE DISCIPLINE SHEET NUMBER SEQUENCE ? XX 000x F1 R1 S3x WALL FUNCTION CORE MATERIAL CORE SIZE (ROUNDED) MODIFIER 101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 100' - 0" MAIN LEVEL LEVEL NAME LEVEL ELEVATION AE000 1 Ref 1 Re f 1 Ref 1 Re f AE000 1 Ref 1 Re f 1 Ref 1 Re f SHEET NUMBER POSITION ON SHEET SHEET NUMBER POSITION ON SHEET DRAWING NUMBER VIEW NAME DRAWING SCALE ORIGINAL SOURCE OF DETAIL A101 1 A101 1 POSITION ON SHEET SHEET NUMBER SHEET NUMBER VIEW DIRECTION POSITION ON SHEET A1 AE101 SIM A1 AE101 SIM A1 AE101 SIM VIEW DIRECTION POSITION ON SHEET SHEET NUMBER ROOM NUMBER ROOM AREA 01A SIGN TYPE SIGN NUMBER VIEW DIRECTION POSITION ON SHEET SHEET NUMBER 1 DELTA MARKER 10' - 0" HEIGHT OF ELEMENT C1 10' - 0" CEILING TYPE CEILING HEIGHT 1 2 A B A1 STARTS AT UPPER LEFT CORNER; NUMBERS ARE VERTICAL GRIDS AND LETTERS ARE HORIZONTAL GRIDS (EXCLUDES LETTERS "I" AND "O") Room name 101 F B W F C P T - 0 1 ? ROOM NAME ROOM NUMBER WALL FINISH BASE FINISH FLOOR FINISH WALL,BASE, OR FLOOR MATERIAL FINISH CODE ARROWS REPRESENT EXTENT OF SCOPE REFER TO FINISH LEGEND WC-01 00.00 ROOM NAME 101 150 KEYNOTE TAG CURTAIN WALL TAG DOOR TAG FLOOR TAG ROOF TAG WALL TAG REVISION CLOUD 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 G001 INDEX, GENERAL NOTES, LOCATION MAP, LEGENDS [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set ABBREVIATION SCHEDULE Abbrev.Description 0 # NUMBER OR POUND & AND 2:1 SL 2 HORIZONTAL TO 1 VERTICAL SLOPE @ AT [ CHANNEL ± PLUS MINUS ≤ LESS THAN OR EQUAL TO ≥ GREATER THAN OR EQUAL TO A AB ANCHOR BOLT AC APSHALTIC CONCRETE ACST ACOUSTIC AD AREA DRAIN ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM ARCH ARCHITECTURAL, ARCHITECT, ARCHITECTURE ASPH ASPHALT B B BASELINE B BOTTOM BEJ BRICK EXPANSION JOINT BLDG BUILDING BLK BLOCK BM BEAM BO BOARD BRG BEARING BSMT BASEMENT C C&G CURB & GUTTER CAP CAPACITY CEM CEMENT CG CORNER GUARD CIP CAST IN PLACE, CAST IRON PIPE CIR CIRCULATING CJ CONTROL JOINT CL CENTERLINE CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNITS COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CPT CARPET CSK COUNTERSUNK CT CERAMIC TILE CTR CENTER D D DEPTH DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DS DOWNSPOUT DWG DRAWING E E EAST E/P EDGE OF PAVEMENT EA EACH EL ELEVATION ELECT ELECTRICAL ELEV ELEVATOR EMER EMERGENCY EQ EQUAL EQUIP EQUIPMENT EW EACH WAY EWC ELECTRIC WATER COOLER EXIST EXISTING EXP EXPANSION EXP JT EXPANSION JOINT EXT EXTERIOR F F.V. FIELD VERIFY FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISHED FLOOR ELEVATION FH FIRE HYDRANT FHC FIRE HOSE CABINET FIN FINISH FLR FLOOR FR FRAME FTG FOOTING FXTR FIXTURE G G GROUND GA GA GALV GALVANIZED GL GLASS GR GRADE GRD GROUND GWB GYPSUM WALL BOARD H HB HOSE BIBB HC HANDICAPPED HDW HARDWARE HGT HEIGHT HORZ HORIZONTAL HR HOUR HW HOT WATER 12" = 1'-0" ARCHITECTURAL SYMBOLS - GI002 GENERAL NOTES - MISCELLANEOUS 1 THE PROJECT MANUAL, UNDER SEPARATE COVER, IS AN INTEGRAL PART OF THESE CONSTRUCTION DRAWINGS. 2 PLANS, SECTIONS, ELEVATIONS, DETAILS AND DIMENSIONS LABELED "TYPICAL" SHALL APPLY TO ALL SITUATION OCCURRING THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY KEYED ON THE DRAWINGS. 3 ALL WORK, MATERIALS, AND METHODS SHALL BE IN CONFORMANCE WITH THE CODES, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION. 4 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION OF SAME ARE PART OF THE CONTRACT AS DEFINED BY THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESSORIES, COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK DEPICTED OR SPECIFIED. 5 CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION ON THE DOCUMENTS. 6 KEEP SITE CLEAN AND CLEAR OF DEBRIS AND IN ORDERLY CONDITION THAT DOES NOT DETRACT FROM THE SURROUNDING SITE AND REPAIR ANY DAMAGE CAUSED BY WORK OF THE CONTRACT. 7 ALL DIMENSIONS ARE TO THE FACE OF METAL OR WOOD STUD FRAMED WALLS AND TO THE FACE OF CONCRETE AND MASONRY WALLS AS SHOWN, UNLESS NOTED OTHERWISE. 8 INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ADJACENT SURFACE. COLOR REQUIRES ARCHITECTS APPROVAL. 9 DOOR OPENINGS IN FRAME CONSTRUCTION WHICH ARE NOT DIMENSIONED ARE EITHER CENTERED IN THE WALL, FACE OF JAMB OR LOCATED 4" FROM THE FACE OF STUD TO THE FINISHED JAMB. 10 ALL SPECIAL ACCESSIBLE FACILITIES SHALL BE IDENTIFIED WITH APPROVED SIGNAGE. 11 THE CONTRACTOR IS RESPONSIBLE FOR PRODUCING A WEATHER TIGHT BUILDING, DETAILS AND OMISSIONS TO DRAWINGS NOTWITHSTANDING. ALL DRAWING CONFLICTS WHICH MAY NOT ALLOW A WEATHERTIGHT CONDITION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 12 DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SPECIFIC DISCREPANCIES FOR ARCHITECT REVIEW. 13 PROVIDE FULL METAL BACKING PLATE (16 GAUGE X 6" HIGH SECURED TO 3 STUDS MIN.) OR WOOD BLOCKING AS REQUIRED TO SECURELY ANCHOR ALL WALL MOUNTED EQUIPMENT (CABINETS, TOILET ROOM ACCESSORIES, HARDWARE, ETC.). BLOCKING SHALL PROVIDE A RIGID CONNECTION CAPABLE OF SUPPORTING DESIGN LOADS. PROVIDE A 16 GAUGE X 6" STL. STUD/TRACK SECURED TO 2 STUDS TO SECURELY SUPPORT ALL WALL STOPS (DOOR BUMPER). 14 COORDINATE WITH ALL TRADES, SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS OR BASES, AS WELL AS ELECTRIC POWER, WATER, AND DRAIN INSTALLATIONS, BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ANY CONCERNS, SPACE LIMITATIONS OR STRUCTURAL CONFLICTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. A REASONABLE RESPONSE TIME SHALL BE ALLOWED AS NOTED IN THE SPECIFICATIONS. 15 ALL FLOOR OR WALL OPENINGS REQUIRED FOR PIPES, DUCTS, CONDUITS,ETC. SHALL BE SEALED IN AN APPROVED MANNER. 16 FIRE SPRINKLER DESIGN TO BE DONE BY A CERTIFIED SUB-CONTRACTOR AND WILL REQUIRE APPROVALS BY THE CITY AND STATE FIRE MARSHAL. APPROVALS BY THE FIRE MARSHAL ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ARCHITECT. SUBMITTAL TO THE ARCHITECT ALSO INDICATES THAT THE CONTRACTOR HAS REVIEWED AND COORDINATED FIRE-SPRINKLER PIPING LOCATIONS WITH ALL TRADES. 17 ROOMS ENCLOSED WITH RATED WALLS REQUIRE RATED DOORS. ANY DUCTS PASSING THROUGH WALLS REQUIRE FIRE DAMPERS AND OR FIRE/SMOKE DAMPERS. ANY CONDUIT OR PIPING REQUIRES RATED SEALANT AT JOINTS. 18 GENERAL STRUCTURAL NOTES GOVERN TYPICAL CONDITIONS WHETHER OR NOT SPECIFICALLY DETAILED OR NOTED. 19 IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CASEWORK, DOORS, ETC. 20 THE DRAWINGS AND SPECIFICATIONS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL AND STRUCTURAL DESIGN CONCEPT. THE DI MENSIONS OF THE BUILDING, THE TYPE OF STRUCTURAL, MECHANICAL, ELECTRICAL AND UTILITY SYSTEMS AND MAJOR ARCHITECTURAL ELEMENTS OF CONSTRUCTION AS "SCOPE" DOCUMENTS. 21 1.THE DRAWINGS AND SPECIFICATIONS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE WORK. CONTRACTS SHALL BE LET ON THE BASIS OF SUCH DOCUMENTS, WITH THE UNDERSTANDING THAT THE CONTRACTOR IS TO FURNISH ALL ITEMS REQUIRED FOR PROPER COMPLETION OF THE WORK WITH OUT ADJUSTMENT TO CONTRACT PRICE. IT IS INTENDED THAT THE WORK TO BE OF SOUND AND QUALITY CONSTRUCTION AND THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE INCLUSION OF ADEQUATE AMOUNTS TO COVER INSTALLATION OF ALL ITEMS INDICATED, DESCRIBED OR REASONABLY IMPLIED. 22 ALL ROOM AND WAYFINDING SIGNAGE IS BY OWNER. PROVIDE BRANDING SIGNAGE SUBMITTALS AND SHOP DRAWINGS TO OWNER (UNIVERSITY COMMUNICATIONS) AND ARCHITECT FOR APPROVAL PRIOR TO PURCHASING AND INSTALLATION. DRAWING INDEX GENERAL G000 COVER SHEET G001 INDEX, GENERAL NOTES, LOCATION MAP, LEGENDS G002 ADA GUIDELINES CONT. G101 CODE ANALYSIS & CODE PLANS G102 CODE ANALYSIS & CODE PLANS, CONT. ARCHITECTURAL DEMOLITION D101 DEMO PLAN D102 DEMOLITION RCP PLAN ARCHITECTURAL A101 FLOOR PLAN A121 DIMENSION PLAN A131 RCP PLAN A141 FINISH PLAN A401 ENLARGED PLAN & INTERIOR ELEVATIONS A401.1 ADD ALTERNATE - ENLARGED PLAN AND ELEVATION A501 WALL ASSEMBLIES & CEILING DETAILS A502 CEILING DETAILS A571 INTERIOR DETAILS A601 DOOR SCHEDULE A611 FINISH SCHEDULES A801 FURNITURE PLAN ABBREVIATION SCHEDULE Abbrev.Description I ID INSIDE DIAMETER IE INVERT ELEVATION INSUL INSULATION INT INTERIOR INTX INTERSECTION INV INVERT J JB JUNCTION BOX JCT JUNCTION JST JOIST JT JOINT L L ANGLE L LENGTH LC LENGTH OF CURVE LDC LEAD COVERED LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LT LIGHT M MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MET METAL MFR MANUFACTURER MH MANHOLE MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MTG MOUNTING MULL MULLION MWP MEMBRANE WATERPROOFING N N NORTH NA NOT APPLICABLE NE NORTHEAST NEC NATIONAL ELECTRIC CODE NEUT NEUTRAL NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE NW NIORTHWEST O OA OUTSIDE AIR OA OUTSIDE AIR OC ON CENTER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OPP OPPOSITE OVHD OVERHEAD P PI POINT IF INTERSECTION PL PLATE PLAS PLASTER PLYWD PLYWOOD PNL PANEL PNT PAINT PRELIM PRELIMINARY PRESS PRESSURE PRIM PRIMARY PRTN PARTITION PT POINT, POINT OF TANGENT Q QT QUARRY TILE R R RADIUS RA RETURN AIR RB RESILIENT VINYL BASE RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN RECP RECEPTACLE REINF REINFORCEMENT REQD REQUIRED REV REVISION RF ROOF RFLCP REFLECTIVE CEILING PLAN RM ROOM RVT RESILIENT VINYL TILE S S SOUTH SCH SCHEDULE SD STORM DRAIN SE SOUTHEAST SECT SECTION SHT SHEET SIM SIMILIAR SL SLOPE SPEC SPECIFICATION SQ SQUARE STL STEEL SUSP SUSPENDED T T TOP T&B TOP AND BOTTOM TEL TELEPHONE TEMP TEMPORARY TERM TERMINAL THK THICK/THICKNESS THRSLD THRESHOLD TO TOP OF TOS TOP OF STEEL, TOP OF SLAB TOW TOP OF WALL TYP TYPICAL U UNO UNLESS NOTED OTHERWISE V VCT VINYL COMPOSITION TILE VENT VENTILIATING VERT VERTICAL VEST VESTIBULE VWC VINYL WALL COVERING W W WIDTH, WEST W/ WITH W/O WITHOUT WC WATER CLOSET WD WIDTH WT WEIGHT WWF WELDED WIRE FABRIC X X TRANSFORMER MECHANICAL M-001 MECHANICAL SCHEDULES AND SYMBOL LEGEND MD-101 SECOND LEVEL MECHANICAL DEMOLITION PLAN MH101 SECOND LEVEL MECHANICAL REMODEL PLAN MH501 MECHANICAL DETAILS MI601 MECHANICAL CONTROL DIAGRAMS FIRE PROTECTION FD101 SECOND LEVEL FIRE PROTECTION DEMOLITION PLAN FP101 SECOND LEVEL FIRE PROTECTION REMODEL PLAN ELECTRICAL ED100 EXISTING ELECTRICAL PLAN EE100 ELECTRICAL PLANS EG100 ELECTRICAL SYMBOLS & DETAILS UNOBSTRUCTED FORWARD REACH OBSTRUCTED FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH 15 M I N 38 0 48 M A X 12 2 0 48 M A X 12 2 0 44 M A X 11 2 0 >20-25 MAX 510-635 20 MAX 510 (a)(b) 10 MAX 255 12 2 0 48 M A X 15 M I N 38 0 10 MAX 255 12 2 0 48 M A X 34 M A X 86 5 34 M A X 86 5 46 M A X 11 7 0 > 10-24 MAX 255-610 (a)(b) DRINKING FOUNTAIN AND BOTTLE FILLING STATIONS ℄ ℄ CLEAR FLOOR SPACE AT WHEELCHAIR DRINKING FOUNTAINS CLEAR FLOOR SPACE AT WHEELCHAIR DRINKING FOUNTAINS - PRIMARILY FOR CHILDRENS USE EXCEPTION MIRROR SOAP DISPENSER PAPER TOWEL DISPENSER TOILET PAPER HOLDER SANITARY NAPKIN DISPOSAL SANITARY NAPKIN DISPENSER BABY CHANGING STATION TOILET SEAT COVERS DISPENSER WASTE RECEPTACLE TO R E F L E C T I V E SU R F A C E TO D I S P E N S E R TO D I S P E N S E R / H A N D L E TO O P E N , F L A T SU R F A C E O F B E D NOTES: 1. WHERE SHOWN, 48" MAX HEIGHT SHALL BE MEASURED FROM FLOOR TO ANY HIGHEST OPERABLE PART 2. PROVIDE BLOCKING FOR ALL EQUIPMENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS 3 ' - 4 " M A X 3 ' - 6 " 4 ' - 0 " M A X 1 5 " M I N 2 ' - 0 " 2 ' - 6 "4 ' - 0 " M A X 2 ' - 1 0 " 4 ' - 0 " M A X T O T O P O F O P E N I N G 4 ' - 0 " M A X TO D I S P E N S E R / H A N D L E 4 ' - 0 " M A X 30 " M I N 30 " M I N CL SIDE WALL CL BACK WALL 60" MIN CLSIDE WALL 60" MIN 15"- 16" 3" M A X 2 1/2" MAX 1 1 / 2 " M A X RECTANGULAR SHOWER COMPARTMENT SEAT STANDARD ROLL-IN SHOWER COMPARTMENT SIZE AND CLEARANCE GRAB BAR IN STANDARD ROLL-IN SHOWERS 6" MAX 48" MAX 6" M A X END WALL END WALL ROLL-IN SHOWER CONTROLS AND HANDSHOWER LOCATION (SHADED AREA) CO N T R O L S 38 " M I N T O B . O . CO N T R O L S 48 " M A X T O T . O . 27" MAX BACK WALL 19 " GRAB BAR SHALL NOT EXTEND OVER SEAT FOLD DOWN OR REMOVABLE SEAT FOLD DOWN OR REMOVABLE SHOWER SEAT 16" MIN NO GRAB BARS ABOVE SHOWER SEAT 48" MIN 36 " M I N 36 " CL CONTROL WALL CL BACK WALL 36" MIN CL SEAT WALL TRANSFER SHOWER COMPARTMENT SIZE AND CLEARANCE 22"- 23" 14 " - 1 5 " 1 1 / 2 " M A X 15"- 16" 2 1/2" MAX 3" M A X L-SHAPED SHOWER COMPARTMENT SEAT 4" MAX CO N T R O L S 3 8 " M I N T O B . O . CO N T R O L S 48 " M A X T O T . O . OUTSIDE OF CONTROLS 15" MAX TOWARD SHOWER OPENING TO CL CONTROL WALL SHOWER CONTROLS AND HANDSHOWER LOCATION 3 3 " M I N - 3 6 " M A X NOTE: CONTROL WALL ALWAYS TO BE OPPOSITE OF SEAT WALL 18 " M I N 3" M I N T O 6 " M A X B E T W E E N HO R I Z O N T A L A N D VE R T I C A L G R A B B A R S Size of Clear Floor Space 30 " M I N 48" MIN Forward 30" MIN 48 " M I N 30 " M I N 48" MIN Parallel Forward Approach 36" MIN x > 2 4 " x > 1 5 " 60" MIN Parallel Approach POSITION OF CLEAR FLOOR SPACE MANEUVERING CLEARANCE IN AN ALCOVEBelow Grab Bar 18 " M I N 1 1 / 2 " M I N CL 7" -9" 12 " M I N CL 7" -9" Above Grab Bar 48 " M A X 6 0 4 .1 0 .7 1 4 "-1 9 " C h i l d r e n 's 12" MAX 42" 39" -41" 54" MIN 1 8 " M I N 3 9 " -4 1 " 3 3 "- 3 6 " 36" 3 3 "- 3 6 " 24" MIN 12" MIN 1 7 " -1 9 " 6 0 4 .1 0 .4 1 1 " - 1 7 " @ c h i l d r e n 's f a c i l i t i e s NOTE: FLUSH CONTRILS SHALL BE LOCATED ON OPEN SIDE OF WATER CLOSET L O C K E R C O N T R O L S 1 5 " M I N - 4 8 " M A X T O T O P O F A C C E S S I B L E 4 ' - 0 " M A X . ACCESSIBLE LOCKER FIRE CABINET CL CUPS ELEC. HAND DRYER COAT HOOKS TOP LOCKER SHELF: 46" MAX. AFF BOT. LOCKER SHELF: 15" MIN. AFF NON ACCESSIBLE LOCKER 60" MIN Circular T-Shaped 60" MIN 3 6 " M I N 6 0 " M I N 12" MIN 36" MIN 12" MIN 2 4 " M I N Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance (a) elevation adult 150 9 MIN 230 6 MIN PARTITION 6 MIN 150 6 MIN 150 (c) plan 6 MIN (b) elevation children 12 MIN 150 305 PARTITION WALL CONSTRUCTION ACCESSORY MOUNTED OVER FINISHED WALL GYPSUM BOARD NOTE: 1. TYPICAL BLOCKING REQUIRED BEHIND WALL MOUNTED ACCESSORIES AND EQUIPMENT (OPTION 1) 20 GA x 6" FLAT STEEL BLOCKING. ATTACH W SELF TAPPING PAN HEAD SCREWS (OPTION 3) SISTER 16 GA. STL. STUD ATTACH FIXTURE TO SISTER STUD W/ SELF TAPPING SCREWS OR ANCHORS (OPTION 2) INLAID FIRE RETARDANT WOOD BLOCKING (COMPLY WITH IBC 2006 2303.2) STUDS SHOWN @ 16" O.C. SEE WALL TYPES FOUNTAIN 20 GA x 6" FLAT STEEL BLOCKING 20 GA x 6" FLAT STEEL BLOCKING 16 GA SUPPORT STUD FOR STL. ANGLE BRACING WATER COOLER/ FOUNTAIN PROVIDE FULL VERTICAL BLOCKING AT CENTERLINE OF URINAL NAPKIN TAMPON HAND DRYER 20 GA x 6" FLAT STEEL BLOCKING TYPICAL BLOCKING DETAILS 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 G002 ADA GUIDELINES CONT. [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 3/8" = 1'-0"B3 (ANSI 308) REACH RANGES 3/8" = 1'-0"B1 (ANSI 602) DF CLEAR FLOOR SPACE 1/2" = 1'-0"C1 TYPICAL MOUNTING HEIGHTS 3/8" = 1'-0"E2 (ANSI 608) ADA ROLL-IN SHOWER 3/8" = 1'-0"D3 (ANSI 608) ADA TRANSFER SHOWER 3/8" = 1'-0"B6 (ANSI 305) CLEAR FLOOR SPACE 3/8" = 1'-0"B2 (ANSI 604) DISPENSER LOCATION 3/8" = 1'-0"A1 (ANSI 604) GRAB BAR PLACEMENT 3/8" = 1'-0"D1 MISCELLANEOUS MOUNTING HEIGHTS 3/8" = 1'-0"E6 (ANSI 304) TURNING SPACE 3/8" = 1'-0"C4 (ANSI 604) ACCESSIBLE COMPARTMENT TOE CLEARANCE A 1 2 3 4 5 6 7 B C D E EXIT #2 EXIT #1 13' -6" 33' -6" 24' -4" 45' -3"40' -3" 64' -4"76' -6" 1,018.92 SF Max. Occ. = 0 WELCOME ROOM 3 187.46 SF Max. Occ. = 0 STORAGE 4 EXISTING STORAGE 9 224.67 SF Max. Occ. = 0 SEATING A 5 306.73 SF Max. Occ. = 0 SEATING B 6 714.25 SF Max. Occ. = 0 WELCOME / HELP DESK 7 CORRIDOR A 10 CORRIDOR B 12 ELEVATOR LOBBY 13 FEC GRAPHIC LEGEND PATH OF EGRESS OCC. Req. Prov. 2" DOOR 36" 10 EXIT WIDTH TAG OCC. Req. Prov. 3" STAIR 60" 10 COMMON PATH OF EGRESS (CPE) ALLOWABLE DISTANCE = 100'-0" TOTAL USED DISTANCE = 100'-0" as per 2015 IBC Table 1006.2.1 TRAVEL DISTANCE (TD) ALLOWABLE EXIT DISTANCE = 250'-0" TOTAL USED EXIT DISTANCE = 240'-0" as per 2015 IBC Table 1017.2 POINT AT WHICH A CHOICE OF 2 EXITS BECOMES AVAILABLE REQUIRED AND PROVIDED DOOR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS as per 2015 IBC Section 1005.3.2 REQUIRED AND PROVIDED STAIR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS as per 2015 IBC Section 1005.3.1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 G101 CODE ANALYSIS & CODE PLANS [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 3/16" = 1'-0"A1 LEVEL 2 CODE PLAN OCCUPANT LOAD SCHEDULE1 Room # Room Name OCC Class Area IBC 2018 - TABLE 1004.1.5 MS-Fixed Seating # of Occ.Sprink'dFunction of Space OLF Group B 3 WELCOME ROOM Group B 1,019 SF Educational - Classroom Area 20 51 Yes 4 STORAGE Group B 187 SF Mercantile - Storage, Stock, Shipping areas 300 1 Yes 5 SEATING A Group B 225 SF Assembly without fixed seats - Unconcentrated (tables and chairs) 15 15 Yes 6 SEATING B Group B 307 SF Assembly without fixed seats - Unconcentrated (tables and chairs) 15 20 Yes 7 WELCOME / HELP DESK Group B 714 SF Assembly without fixed seats - Unconcentrated (tables and chairs) 15 48 Yes 13 ELEVATOR LOBBY Group B 198 SF (none) Grand Total 0 135 CODE ANALYSIS APPLICABLE CODES YEAR YEAR INTERNATIONAL BUILDING CODE INTERNATIONAL MECHANICAL CODE INTERNATIONAL PLUMBING CODE INTERNATIONAL FIRE CODE INTERNATIONAL ENERGY CONSERVATION CODE NATIONAL ELECTRICAL CODE UNIFORM CODE FOR BUILDING CONSERVATION ADA ACCESSIBILITY GUIDELINES A. OCCUPANCY AND GROUP: CHANGE IN USE: YES SPECIAL USE AND OCCUPANCY (e.g. HIGH RISE, COVERED MALL): MIXED OCCUPANCY: YES B. SEISMIC DESIGN CATEGORY:DESIGN WIND SPEED (mph): C. TYPE OF CONSTRUCTION (CIRCLE ONE): I A V B I B II A II B III A III B IV HT V A D. FIRE RESISTANCE RATING REQUIREMENTS FOR THE EXTERIOR WALLS BASED ON THE FIRE SEPARATION DISTANCE (IN HOURS): NORTH EAST SOUTH WEST E. MIXED OCCUPANCIES: NON-SEPARATED USES: F. SPRINKLERS: REQUIRED: PROVIDED: TYPE OF SPRINKLER SYSTEM: G. NUMBER OF STORIES: BUILDING HEIGHT: H. ACTUAL AREA (Aa) PER FLOOR (SF, SEE AREA SCHEDULE): I. TABULAR AREA (At): J. AREA MODIFICATIONS: K. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) L. DESIGN OCCUPANT LOAD: EXIT WIDTH REQUIRED (inches): EXIT WIDTH PROVIDED: M. MINIMUM NUMBER OF REQUIRED PLUMBING FACILITIES: (SEE "PLUMBING CODE CALCULATION" SCHEDULE & "PROVIDED PLUMBING FIXTURE SCHEDULE") FOOTNOTES: 1) IN CASE OF CONFLICT WITH THE U.S. DEPARTMENT OF JUSTICE FEDERAL REGISTERS PARTS I THROUGH V - ADA GUIDELINES AND SPECIFIC REFERENCE TO THE INTERNATIONAL BUILDING CODE ACCESSIBILITY CHAPTERS, THE MORE RESTRICTIVE REQUIREMENT SHALL GOVERN. 2) ADDITIONAL CODE INFORMATION SHALL BE PROVIDED AT THE DISCRETION OF THE BUILDING OFFICIAL FOR COMPLEX BUILDINGS. INCLUDING, BUT NOT LIMITED TO: a) HIGH RISE REQUIREMENTS b) ATRIUMS c) PERFORMANCE BASED CRITERIA d) MEANS OF EGRESS ANALYSIS e) FIRE ASSEMBLY LOCATOR SHEET f) EXTERIOR AND INTERIOR ACCESSIBILITY ROUTE g) FIRE STOPPING, INCLUDING TESTED DESIGN NUMBER NO NO a) Aa = At + (NS x If) c) SUM OF THE RATIO CALCULATIONS FOR MIXED OCCUPANCIES: ACTUAL AREA / ALLOWWABLE AREA ≤ 1 b)If = [F/P - 0.25 ] W/30 ELEMENT HOURS ASSEMBLY LISTING Primary Structural Frame Bearing Walls -Exterior Bearing Walls -Interior Nonbearing Walls/Partitions -Interior Nonbearing Walls/Partitions -Exterior Floor construction and associated secondary members Roof construction and associated secondary members Exterior Doors & Windows Shaft Enclosures Fire Walls Fire Partitions Smoke Partitions Fire Barriers Yes Yes 27" SINGLE OCCUPANCY ONE STORY 2018 2018 2010 2018 2018 2018 2018 C 100 YES (EXISTING) 4 75' - 3" 0.00 SF 30' - 0" [ 0' / 0' - 0.25 ] 0' / 30 0 + ( 0 x - - - - - - - - - NONE NONE NONE EXISTING NONE 0.00 SF / 0.00 SF = 136 (ONLY ONE STORY BEING REMODELED)(EXISTING) (ONLY A PORTION OF LEVLE 2 IS BEING REMODELED - APPROXIMATLEY 4,000 SF REMODEL) 4 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 12 1314 15 15 16 16 20 20 25 25 28 28 30 30 32 32 34 34 38 38 40 40 41 41 42 42 43 43 45 45 46 46 47 47 48 48 50 50 36 36 51 51 A A B B C C D D E E F F G G H HJJ L L P P T T U U W W Z Z CC CC GG GG KK KK LL LL NN NN 1 1 11 17 17 18 18 19 19 21 21 22 22 23 23 24 24 26 26 27 27 29 29 31 31 33 33 35 35 37 37 39 39 44 44 49 49 K K M M N N Q Q R R S S V V X X Y Y AA AA BB BB DD DD EE EE FF FF HH HH JJ JJ MM MM A.5 A.5 12.1 12.5 10 12 131411 12.1 12.5 DN DN DN DN DN DN DN DN WELCOME ROOM WELCOME / HELP DESK SEATING A SEATING B STORAGE CORRIDOR CORRIDOR NOTE THAT THIS EXISTING FLOOR PLAN SHOWS GRID LINES THAT REFLECT THE RECORD DRAWINGS FOR THE MANWARING CENTER. NEW GRID LINES HAVE BEEN RENUMBERED TO ADJUST TO THE NEW WELCOME CENTER REMODEL. GRAPHIC LEGEND PATH OF EGRESS OCC. Req. Prov. 2" DOOR 36" 10 EXIT WIDTH TAG OCC. Req. Prov. 3" STAIR 60" 10 COMMON PATH OF EGRESS (CPE) ALLOWABLE DISTANCE = 100'-0" TOTAL USED DISTANCE = 100'-0" as per 2015 IBC Table 1006.2.1 TRAVEL DISTANCE (TD) ALLOWABLE EXIT DISTANCE = 250'-0" TOTAL USED EXIT DISTANCE = 240'-0" as per 2015 IBC Table 1017.2 POINT AT WHICH A CHOICE OF 2 EXITS BECOMES AVAILABLE REQUIRED AND PROVIDED DOOR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS as per 2015 IBC Section 1005.3.2 REQUIRED AND PROVIDED STAIR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS as per 2015 IBC Section 1005.3.1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 G102 CODE ANALYSIS & CODE PLANS, CONT. [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set1" = 20'-0"A1 CONSTRUCTION EGRESS PLAN A 1 2 3 4 5 6 7 B C D E EXISTING STORAGE 9 CORRIDOR A 10 02.08 NOT IN CONTRACT (SHADED AREA) ELEVATOR LOBBY 13 CORRIDOR B 12 EXISTING OFFICES EXISTING COMPACT STORAGE EXISTING INFO DESK EXISTING SEATING EXISTING SEATING 02.0902.09 02.08 02.01 02.01 02.01 02.02 02.01 02.01 02.01 02.01 02.06 02.04 02.0302.03 02.03 02.03 02.03 02.13 02.14 EXISTING WALLS TO REMAIN, REFER TO DEMOLITION PLANS FOR REMOVAL OF EXISTING WALLS LEGEND WALLS AND ITEMS TO BE DEMOLISHED OR MOVED. SEE KEYNOTES. REMOVE AND DISPOSE OF EXISTING DOORS N.I.C. REMOVE EXISTING FLOORING AND PREP FOR NEW FLOORING; ALL CARPET TILES TO BE CAREFULLY REMOVED AND STORED FOR REUSE 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 D101 DEMO PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 LEVEL1 DEMOLITION PLAN GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION KEYED NOTES 02.01 REMOVE WALL 02.02 REMOVE DOOR ASSEMBLY 02.03 REMOVE TILE/TRAVERTINE FLOOR AS NEEDED, TO COORDINATE WITH NEW GLAZING SYSTEMS 02.04 OWNER WILL RELOCATE EXISTING KEY BOX. POWER AND DATA WILL NEED TO BE PROVIDED IN NEW LOCATION. RE; ELECTRICAL DRAWINGS 02.06 REMOVE FLOORING UP TO EXPANSION JOINT 02.08 REMOVE MILLWORK, CONTRACTOR SHALL VERIFY WITH OWNER FOR ANY ITEMS TO BE SALVAGED/PRESERVED PRIOR TO DEMO 02.09 REMOVE COMPACT STORAGE AND WALL SHELVING, CONTRACTOR SHALL SALVAGE AND RETURN TO OWNER, INCLUDING TRACK. 02.13 SAW CUT OPENING FOR NEW DOOR. RE: FLOOR PLANS AND DOOR SCHEDULE FOR NEW OPENING. 02.14 SAW CUT OPENING FOR NEW MECHANICAL VENT. RE: FLOOR PLAN AND DIMENSION PLANS. A 1 2 3 4 5 6 7 B C D E NOT IN CONTRACT (SHADED AREA) 02.07 02.10 EXISTING WALLS TO REMAIN, REFER TO DEMOLITION PLANS FOR REMOVAL OF EXISTING WALLS LEGEND WALLS AND ITEMS TO BE DEMOLISHED OR MOVED. SEE KEYNOTES. REMOVE AND DISPOSE OF EXISTING DOORS N.I.C. REMOVE EXISTING ACOUSTICAL CEILING TILE, GRID SYSTEM AND GYPSUM BOARD CEILING WITH SUPPORT STRUCTURE. SAVE EXISTING TILE AS NEEDED TO REPLACE THE 16'-0" TILE ON THE NORTH SIDE OF THE PROJECT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIGHTING, DIFUSERS AND GRILLES. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 D102 DEMOLITION RCP PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 DEMOLITION REFLECTED CEILING PLAN GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION KEYED NOTES 02.07 REMOVE EDGE OF 16'-0" TALL CEILING TILE TO PREP FOR INFILL BETWEEN COLUMNS, EXISTING TILE IS TO BE REUSED FOR THIS AREA. SAVE THE APPROPRIATE AMOUNT OF EXISTING CEILING TILE TO COMPLETE THIS AREA. 02.10 EXISTING CEILING GRID TO REMAIN. REPLACE ACOUSTICAL CEILING TILE, RE: REFLECTED CEILING PLAN RE F . A 1 2 3 4 5 6 7 B C D E A401A5 A401 B2 A401A3 A401C2 A401 A2 A401 C1 A401 C3 ________________D6 A401SEATING A 5 SEATING B 6 WELCOME / HELP DESK 7 WELCOME ROOM 3 STORAGE 4 EXISTING STORAGE 9 CORRIDOR A 10 A401 C4 A401 B1 A401 A1 CORRIDOR C 11 CORRIDOR B 12 NOT IN CONTRACT (SHADED AREA) ________________A1 A401.1 3A 4 3B 3D FG1 SF1FG1 FG2 FG3FG4 A401B5 11.01 08.0108.01 08.01 A401D4 18" E4 21.01 23.03 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A101 FLOOR PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 FLOOR PLAN GENERAL NOTES - FLOOR PLAN 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE THE DRAWINGS 3 ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT 4 ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE 5 SEE G000's FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT 6 COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED 7 SEE SHEET SERIES A500's FOR WALL AND ASSEMBLY TYPES 8 SEE SHEET SERIES A600's FOR DOOR AND WINDOW TYPES 9 SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS 10 SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION 11 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400'S. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS 12 ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS 13 SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE A400's UNIT SHEET SERIES FOR LOCATIONS 14 DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE ALTERNATE KEYED NOTES 08.01 ALUMINUM FRAMED STORE FRONT DOOR FRAME SYSTEM, RE: DOOR SCHEDULE AND FRAME TYPES 11.01 REFRIGERATOR; OFOI, 21.01 FIRE EXTINGUISHER CABINET, RE: CODE REVIEW PLAN. VERIFY LOCATION WITH OWNER PRIOR TO PLACEMENT. 23.03 12" WIDE X 16" TALL OPENING TO BE 8" ABOVE THE FINISH FLOOR (ON COURSING) FOR VENTELATION TO AV EQUIPMENT. PROVIDE l5X5X1/4 ANGLE FOR LINTEL. 4" BEARING ON EACH SIDE. PROVIDE MECHANICAL GRILL, RE: MECHANICAL DRAWINGS. RE F . A 1 2 3 4 5 6 7 B C D E 324.13 SF EXISTING STORAGE 9 187.46 SF STORAGE 4 1,018.92 SF WELCOME ROOM 3 ALIGN ALIGN S4a 12 ' - 6 3 / 4 " 6' - 9 1 / 2 " ALIGN ALIGN 1'-6 3/4" 1' - 6 3 / 4 " 1'-6 3/4" 1' - 6 3 / 4 " 1'-6 3/4" 1' - 6 3 / 4 " 4' - 3 3 / 4 " 7' - 7 3 / 4 " 5' - 3 1 / 4 " 9'-10 1/2"16'-0 3/8" 1' - 1 0 5 / 8 " 2'-9 5/8" WV1 WV1 WV1 WV1 WV1 WV1 WV1 WV1 WV1 WV1 WV1 WV1 S4a S4a S4aS4aS4a S4aS4a S4aS4a S4a S4a S4a S4a S4a.1 S4a WV1 WV1 S4a S4a 7/8" HAT CHANNEL W/ 5/8" GYP BOARD & 3/4" WOOD PANEL (WV-1 VEENEER) WELCOME / HELP DESK 7 SEATING B 6 SEATING A 5 CORRIDOR A 10 ELEVATOR LOBBY 13 S4a S4a S4aS2a AL I G N AL I G N AL I G N AL I G N AL I G N AL I G N NOT IN CONTRACT (SHADED AREA) 1' - 0 " V E R I F Y W / C O U R S I N G 5 '-4 " 09.14 09.14 09.14 09.13 09.13 09.13 09.14 09.14 09.14 09.1309.1309.13 09.12 09.11 09.1409.14 23.03 A. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK B. DO NOT SCALE THE DRAWINGS C. ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT D. ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE E. SEE G000'S FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT F. COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED G. SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES H. SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES I. SEE ELEVATIONS AND FINISH PLANS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS J. SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION K. DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE. L. ALL PANEL MOLDING TO HAVE MITERED CORNERS AND CONSISTANT MOUNTING HEIGHT AND SPACING WITHIN THE SAME SPACE. M. WALL TYPES ARE TAGGED FOR THE LENGTH OF THE ENTIRE WALL RUN, UNLESS NOTED OTHERWISE N. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD WALLS AS SHOWN, UNLESS NOTED OTHERWISE O. FOR WOOD WALL PANEL LOCATIONS, RE: FINISH PLANS AND ELEVATIONS GENERAL NOTES 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A121 DIMENSION PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 LEVEL 1 DIMENSION PLAN KEYED NOTES 09.11 CONTINUE GYPSUM BOARD FROM THE METAL STUD WALL INFILL, TO THE INSIDE CORNERS OF THE ROOM 09.12 PROVIDE R-13 INSULATION IN METAL WALL ON THE NORTH SIDE OF INFILL 09.13 GYPSUM BOARD SOFFIT ABOVE, SEE RCP'S 09.14 PROVIDE R-13 INSULATION IN THE NEW AND EXISTING WALLS WHERE POSSIBLE, AND ABOVE WALL UP TO THE BOTTOM OF EXISTING DECK, AROUND THE PERIMETER OF THE WELCOME ROOM. PROVIDE ACOUSTICAL GYPSUM BOARD UP TO DECK AND SEALANT AT DECK LEVEL. 23.03 12" WIDE X 16" TALL OPENING TO BE 8" ABOVE THE FINISH FLOOR (ON COURSING) FOR VENTELATION TO AV EQUIPMENT. PROVIDE l5X5X1/4 ANGLE FOR LINTEL. 4" BEARING ON EACH SIDE. PROVIDE MECHANICAL GRILL, RE: MECHANICAL DRAWINGS. A 1 2 3 4 5 6 7 B C D E A1 10' - 0" B1 10' - 0" B1 10' - 0" SEATING A 5 SEATING B 6 WELCOME / HELP DESK 7 STORAGE 4 WELCOME ROOM 3 CORRIDOR A 10 4 " TYP 4" ALIGN B1 9' - 0" NOT IN CONTRACT (SHADED AREA) 10' - 0"D1 B1 9' - 0"B1 9' - 0"B1 9' - 10" B1 9' - 0" B1 9' - 0"B1 9' - 0"B1 9' - 0" 12.02 12.0212.0212.02 12.0212.0212.02 ELEVATOR LOBBY 13 A1 10' - 3" A1 10' - 3" TYP B3 A501 B4 A501 A3 A501 B2 10' - 0" A2 8' - 9 3/4" D4 A501 TYP D4 A501 TYP D4 A501 TYP A1 A502 4" 8'-4" 5 '-2 1 /4 " A1 10' - 3" A1 10' - 3" A3 A501 B2 10' - 0" B2 10' - 0" ACT-01: 2' x 2' LAY-IN ACOUSTICAL TILE & SUSPENSION SYSTEM, RE: FINISH SCHEDULE, VERTICAL WIRING ONLY, NO HORIZONTAL OR ANGLED CEILING LEGEND TYPE A1 NOTE: SEE MECHANICLA AND ELECTRICAL DRAWINGS FOR LIGHT FIXTURES, DIFUSERS, ETC... 5/8" GYPSUM BOARD (PAINTED PNT-02 UNLESS NOTED ON PLAN) ON METAL SUSPENSION SYSTEM, VERTICAL WIRING ONLY, NO HORIZONTAL TYPE B1 AREA NOT IN CONTRACT - OUSIDE PROJECT SCOPE N.I.C LINEAR WOOD CEILING SYSTEM, SC-01; RE: FINISH SCHEDULE, VERTICAL CABLE OR ALL THREAD, NO HORIZONTAL TYPE D1 NOTE: ALL DROPS NEED TO BE NON-COMBUSTABLE METAL FRAMING OR LIGHT GUAGE METAL FRAMING AND MEET L/360 STANDARD FOR ALLOWABLE DEFLECTION. EXISTING 2' x 2' LAY-IN GRID SYSTEM, UPDATE EXISTING SUSPENSION SYSTEM AS NEEDED, AND ACOUSTICAL CEILING TILE PER FINISH SCHEDULE TYPE A2 EXPOSED CEILING, PAINTED PNT-05; RE: FINISH SCHEDULE E1 EXISTING GYPSUM BOARD CEILING TYPE B2 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A131 RCP PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 REFLECTED CEILING PLAN KEYED NOTES 12.02 ROLLER SHADES, RS-01, SINGLE SHADE WITH MOTORIZED SYSTEM, 1% OPENNESS CFCI; RE: FINISH SCHEDULE GENERAL NOTES - CEILING... 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE DRAWINGS 3 CEILING GRID SHOWN IS ONLY A GRAPHIC REPRESENTATION OF CEILING. CONTRACTOR SHALL VERIFY ACTUAL GRID LAYOUT/LOCATION IN THE FIELD. CONTRACTOR SHALL CENTER GRIDS IN ROOMS, UNLESS NOTED OTHERWISE 4 VERIFY AND COORDINATE ALL MECHANICAL DUCT, GRILLE, DIFFUSER, AND VENT LOCATIONS, LAYOUT, AND QUANTITIES WITH MECHANICAL DRAWINGS. 5 VERIFY AND COORDINATE ALL ELECTRICAL FIXTURE, LIGHT, SMOKE DETECTOR, AND EXIT DEVICE LOCATIONS, LAYOUT, AND QUANTITIES WITH ELECTRICAL DRAWINGS 6 CONTRACTOR TO MAXIMIZE CEILNG HEIGHT DEPENDENT ON DUCTWORK LOCATIONS. 7 SEE SHEET SERIES A500 FOR TYPICAL FIXTURE SUPPORT, CLIP ANGLES, AND SEISMIC BRACING DETAILS 8 PROVIDE DEFLECTION TRACKS AT TOP OF ALL COLD FORMED METAL FRAMING WALLS; SEE SHEET SERIES AE500 324.13 SF EXISTING STORAGE 9 DI R E C T I O N O F F L O O R I N G DIRECTION OF FLOORING WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WV-01, WB-02 WS-01, WB-02 WS-01, WB-02 WV-01, WB-02 WV-01, WB-02 WS-01, WB-02 WV-01, WB-02 SEATING A 5 CPT-01 WB-01 PNT-01 SEATING B 6 CPT-01 WB-01 PNT-01 WELCOME / HELP DESK 7 CPT-01 WB-01 PNT-01 WELCOME ROOM 3 CPT-02 WB-01 PNT-01 STORAGE 4 CPT-01 WB-03 PNT-03 PNT-01, WB-01 PNT-01, WB-01 PNT-04 PNT-04PNT-04 PNT-03, WB-03 ELEVATOR LOBBY 13 CPT-01 CORRIDOR A 10 CPT-01 - - 1,566.22 SF CORRIDOR B 12 NOT IN CONTRACT (SHADED AREA) FLOOR FINISH LEGEND CARPET TILE Room name 101 F B W WALL FINISH BASE FINISH FLOOR FINISH ROOM NUMBER FINISH KEY FINISH CODE; REFER TO ELEVATIONS FOR ENTIRE SCOPE. REFER TO FINISH SCHEDULE FOR BASIS OF DESIGN. CPT-02 CPT-01 AREA NOT IN SCOPE NOTE: INDICATES MAIN FIELD FINISH; ASSUME THIS FINISH IN ENTIRE AREA UNLESS AN ACCENT IS CALLED OUT IN PLANS OR ELEVATION CARPET TILE *MULTIPLE FINISHES; SEE ELEVATION TYP. ROOM FINISH TAG ACCENT TAG XX - X X EX T E N T O F F I N I S H SC O P E CARPET TILECPT-03 REFER TO FINISH SCHEDULE 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A141 FINISH PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 LEVEL 1 FINISH PLAN GENERAL NOTES - FINISH 1 SEE FLOOR PLANS FOR INTERIOR ELEVATIONS 2 ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 3 FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE 4 PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION 5 REFER TO ROOM FINISH LEGEND ON SHEET SERIES A600's FOR MORE INFORMATION 6 SEE DIMENSION PLAN SHEET SERIES A120's FOR WALL TYPE LOCATIONS; SEE SHEET SERIES A500's FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS 7 CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, AND EQUIPMENT. COORDINATE WITH ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS 8 SEE SHEET SERIES A500's FOR TYPICAL DETAILS 9 TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES 10 ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK 11 VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION 12 ALL GROUT TO BE SEALED 13 GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT WITH FURNITURE PROVIDER 14 LEVEL 5 FINISH REQUIRED FOR ALL WALL GRAPHIC AND WALLCOVERING LOCATIONS. SEE FINISH PLANS AND ELEVATIONS FOR LOCATIONS 15 ALL METAL STUD WALLS TO DECK ABOVE, UNLESS NOTED OTHERWISE; SEE SHEET SERIES A500's FOR WALL TYPES 16 PROVIDE DEFLECTION TRACKS AT ALL STUD WALLS, SEE DETAILS ON SHEET SERIES A500's 17 ALL EXPOSED METAL TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 18 CREATE A CLEAN, STRAIGHT TRANSITION LINE FROM POLISHED SEALED CONCRETE FLOORING TO SEALED CONCRETE FLOORING UNDER DOORS. USE APPROPRIATE MEANS TO ACHIEVE A CLEAN TRANSITION OPEN TO BEYOND 06.01 09.05 3 /4 " T V C E N T E R E D W I T H I N F R A M E 4 '-3 1 /2 " 3 /4 " 5 7 /8 " 2 '-7 " 09.03 OPEN TO BEYOND 11.07 EQ 6'-0"EQ EQ 3/4" TV CENTERED WITHIN FRAME 6'-11 7/8"3/4"EQ 11.04 11.07 B5 A571 A5 A571 B4 A571 EQ 3/4" TV CENTERED WITHIN FRAME 2'-8 1/2"3/4"EQ 3 /4 " T V C E N T E R E D W I T H I N F R A M E 3 '-1 0 1 /8 " 3 /4 " 2 '-1 0 3 /4 " 06.01 09.05 OPEN TO BEYOND OPEN TO BEYOND 10.17 10 3/8" 18" 8 '-7 1 /8 " 8 1 /8 " 09.09 1 2 '-0 " A6 A571 A571 A4 11.08 EQ EQ CL CL 09.05 06.01 11.04 6 '-2 1 /4 " EQ 3/4" 6'-11 7/8" 3/4" EQ 4 '-0 1 /2 " 4 '-3 1 /2 " 10.18B5 A571 A5 A5714 06.01 09.05 BOTTOM OF ADACENT CEILING TYP. TYP. 10.17 09.09 08.01 TYP. OPEN TO BEYOND 11.08 8 1 /8 " 11.09 3 /4 " 3 '-1 0 1 /8 " 3 /4 " 2 '-1 0 3 /4 " 11 1/4" 3/4" COORDINATE FINAL PLACEMENT WITH TV MOUNT 2'-8 1/2" 3/4" 1'-0" 4 '-1 0 1 /2 " CL JOINT EXPANSION A6 A571 A571 A4 OPEN TO BEYOND 06.01 09.05 06.01 08.03 EQ 22"EQ 5 1 /2 "4 2 " 423 2 1/8" 24" OPEN TO BEYOND B2 A571 A401 E3 A401 D3 A401 D2 A401E2 MIR A401D2 MIR A401 E2 A1 A571 A2 A571 A2 A571 A2 A571 OPEN TO BEYOND 230 4"15"31"9" 230 1 0 " 3 0 " 06.02 TYP. TYP. 12.0412.0412.04 A2 A571 OPEN TO BEYOND 06.03 1 1/2"87 7/8" 3 0 " 12.04 A2 A571 OPEN TO BEYOND 39 3/4"108"39 3/4" 1 0 " 3 0 " 12.04 06.03 12.04 10.19 A1 A571A2 A571 3 0 " 32 1/4"3"24"73 3/4"24"3"32 1/4" OPEN TO BEYOND 12.0412.04 TYP. 211 211 06.02 TYP. 12.04 A1 A571 12.0406.02 3 4 " 211 211 211 211 230 09.07 1 0 '-0 " 09.01 08.01 11.02 TYP 24"24"24"24"24"FILLER VERIFY W/ FRIDGE 2'-2 3/4" 09.04 09.03 09.02 09.02 09.03 10.20 10.16 TYP OPEN TO BEYOND 02.09 WALL FURRING TO MATCH EXISTING COLUMN DEPTH 09.01 09.04 09.10 09.01 TYP TYP 10.16 TYP OPEN TO BEYOND OPEN TO BEYOND 06.01 CL EQ 3/4" TV CENTERED WITHIN FRAME 6'-11 7/8"3/4" 3 /4 " T V C E N T E R E D W I T H I N F R A M E 4 '-3 1 /2 " 3 /4 " 3 '-1 " CL 09.05 06.03 5 '-3 1 /2 " EQ EQ B5 A571 A5 A571 11.04 B4 A571 11.07 OPEN TO BEYOND BOTTOM OF ADJACENT CEILING 10.17 02.11 EQ EQ EQ EQ EQ EQ FIELD VERIFY 21'-11 1/2" 1 0 '-3 " 1 6 '-1 0 1 /2 " 09.07 09.04 09.01 10.16 CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 423 423 423 423 423 COORDINATE WITH OWNER PROVIDED EQUIP. 36 3/4"24"24"24"24"24" 06.02 8 4 " 11.01 02.12 O P E N I N G F O R V E N T /G R I L L 1 '-4 " 8 " 6'-6 1/8" OPENING FOR VENT/GRILL 1'-0" 1'-8" 05.14 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A401 ENLARGED PLAN & INTERIOR ELEVATIONS [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set GENERAL NOTES - INTERIOR ELEVATIONS 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE DRAWINGS 3 SEE SHEET SERIES G000's FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT 4 UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE 5 UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYPICAL 6 ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE HORIZONTALLY ALIGNED AND MOUNTED HORIZONTALLY 7 PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8 PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS; SEE DETAILS AND FINISH SCHEDULE 9 PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS; SEE DETAILS AND FINISH SCHEDULE 10 ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 11 CONTRACTOR TO PROVIDE RESTROOM ACCESSORIES; SEE ACCESSORY SCHEDULE 12 SEE AF600 SERIES FOR MATERIAL SPECIFICATIONS 13 SEE SHEET SERIES A500's FOR WALL AND ASSEMBLY TYPES 14 SEE SHEET SERIES A600's FOR DOOR AND WINDOW TYPES 15 SEE SHEET SERIES A500's FOR CASEWORK DETAILS 1/4" = 1'-0"A5 SEATING B - WEST 1/4" = 1'-0"A3 WELCOME/HELP DESK - WEST 1/4" = 1'-0"C2 WELCOME ROOM A - WEST 1/4" = 1'-0"A2 CORRIDOR A - NORTH 1/4" = 1'-0"C1 WELCOME ROOM - SOUTH 1/4" = 1'-0"C3 WELCOME ROOM A - NORTH KEYED NOTES 02.09 REMOVE COMPACT STORAGE AND WALL SHELVING, CONTRACTOR SHALL SALVAGE AND RETURN TO OWNER, INCLUDING TRACK. 02.11 EXISTING WALL, FINISH TO REMAIN, PROTECT DURING CONSTRUCTION, REMOVE CORNER GUARD 02.12 EXISTING WALL BASE, FINISH TO REMAIN, REPLACE AS NEEDED, BY OWNER 05.14 L5X5X1/4" ANGLE IRON AT WALL OPENING FOR SUPPORT, 4" BEYOND OPENING ON EACH SIDE 06.01 WOOD VENEER PANEL, WV-01, RE: FINISH SCHEDULE 06.02 LAMINATE FINISH, PL-01, RE: FINISH SCHEDULE 06.03 SOLID WOOD SLAT, WS-01, RE: FINISH SCHEDULE 08.01 ALUMINUM FRAMED STORE FRONT DOOR FRAME SYSTEM, RE: DOOR SCHEDULE AND FRAME TYPES 08.03 OPENING FOR RECESSED TEACHING STATION REQUIRED, 22"Wx42"H, OWNER PROVIDED/OWNER INSTALLED 09.01 PAINTED GYP, PNT-01, RE: FINISH SCHEDULE 09.02 PAINTED GYP, PNT-03, RE: FINISH SCHEDULE 09.03 PAINTED GYP, PNT-04, RE: FINISH SCHEDULE 09.04 WALL BASE, WB-01, RE: FINISH SCHEDULE 09.05 WALL BASE, WB-02, RE: FINISH SCHEDULE 09.07 BOTTOM OF ADJACENT CEILING/CLOUD, WALL FINISH CONTINUES UP TO FLOOR DECK, RE: FINISH SCHEDULE 09.09 PAINTED GYP, PNT-05, RE: FINISH SCHEDULE 09.10 INFILL FRAMING AND GYP BOARD BETWEEN COLUMNS TO BE FLUSH WITH EXISTING COLUMNS. COORDINATE CEILING GRID WITH INFILL 10.16 VINYL GRAPHICS APPLIED TO EXTERIOR GLAZING AT WELCOME ROOM, BY OWNER 10.17 1/2", CNC CUT, MDF LETTERS, PAINTED FINISH, FONT: IMPACT, 18" X-HEIGHT, ADHERED TO SURFACE IN A CONCEALED, PERMANANT MANNER 10.18 BRUSHED ALUMINUM, 6"H EXTRUDED LETTERING, OWNER PROVIDED/ OWNER INSTALLED 10.19 BRUSHED ALUMINUM, EXTRUDED LETTERING, CAMPUS STANDARD, OWNER PROVIDED/ OWNER INSTALLED 10.20 VINYL GRAPHIC, BYUI SEAL, BY OWNER 11.01 REFRIGERATOR; OFOI, 11.02 UNDER COUNTER MINI FRIDGE W/ LOCK, SUMMIT AL55, 31.63X23.5X23.38, OFCI 11.04 FLAT PANEL DISPLAY TV, SIZE: 48.6"x28.1", OWNER PROVIDED, CONTRACTOR INSTALLED, 3/4" BLOCKING AT ALL LOCATIONS 11.07 ELECTRIC FIREPLACE, PRODUCT: REGAL FLAME, GOTHAM 72" BUILT-IN VENTLESS HEATER, PEBBLE, #LW2072WS, HEATER TO BE DISABLED PRIOR TO INSTALLATION 11.08 FLAT PANEL DISPLAY TV, SIZE: 24.5X38.1, HORIZONTAL, OWNER PROVIDED, CONTRACTOR INSTALLED, 3/4" BLOCKING AT ALL LOCATIONS 11.09 TV MOUNTED TO LEFT SIDE OF EXPANSION JOINT, COORDINATE BRACKET AND PLACEMENT WITH ARCHITECT PRIOR TO WOOD WALL INSTALLATION, OWNER PROVIDED, CONTRACTOR INSTALLED 12.04 STONE COUNTERTOP, ST-01, RE: FINISH SCHEDULE 1/2" = 1'-0"D6 ENLARGED WELCOME/HELP DESK 1/4" = 1'-0"E2 WELCOME/HELP DESK INT.- WEST & MIR EAST 1/4" = 1'-0"D2 WELCOME/HELP DESK - EAST & MIR WEST 1/4" = 1'-0"D3 WELCOME/HELP DESK INTERIOR - NORTH 1/4" = 1'-0"E3 WELCOME/HELP DESK INTERIOR - SOUTH 1/4" = 1'-0"B2 SEATING A + B & WELCOME/HELP DESK - NORTH 1/4" = 1'-0"C4 CORRIDOR C - SOUTH 1/4" = 1'-0"B1 SEATING A - EAST 1/4" = 1'-0"A1 CORRIDOR A - WEST 1/4" = 1'-0"B5 CORRIDOR B - WEST 1/4" = 1'-0"D4 STORAGE 4 - WEST 1/4" = 1'-0"E4 STORAGE 4 - EAST HOLLOW INTERIOR 2'-3 1/2"5'-9 1/8"6'-9 1/4"6'-5 5/8"2'-0 5/8" 6 '-1 1 7 /8 " POWDER COATED, STAINLESS STEEL A401.1 A3 2 '-0 " FINAL LOCATION TO BE COORDINATED WITH OWNER; LIGHTING OF SIGN TO BE IMPLEMENTED 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A401.1 ADD ALTERNATE - ENLARGED PLAN AND ELEVATION [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A3 "BYUI" EXTERIOR SIGNAGE - FRONT ELEVATION 1/2" = 1'-0"A1 ENLARGED EXTERIOR "BYUI" SIGN 1 1/2" = 1'-0"B1 "BYUI" SIGN RENDERING NOTE: THIS SIGNAGE IS AN ADD ALTERNATE. DETAILS AND MATERIALS WILL BE PART OF A DESIGN/BUILD PROCESS AT A LATER TIME, IF ACCEPTED. GYP BOARD ON 3-5/8" STEEL STUD FRAMING 3 5/8" METAL STUD BRACING @ 16" O.C. DIAGONAL BRACING @ 48" O.C. FOR HEIGHT SEE RCP PLANS SCHED. CEILING TILE - SEE RCP FOR HEIGHT 3-5/8" METAL STUD BRACING @ 16" O.C. WOOD VENEER SHADOW MOLDING REVEAL BY MFR. 0' - 6 " SHADOW MOLDING REVEAL BY MFR. SCHED. CEILING TILE - SEE RCP FOR HEIGHT DIAGONAL BRACING @ 48" O.C. SCHED. CEILING CEILING GRID MAIN RUNNER OR CROSS TEE PNT 5/8" GYPSUM BOARD ON 3-5/8" COLD FORMED FRAMING 3 5/8" METAL STUD BRACING @ 16" O.C. 0' - 6 " DIAGONAL BRACING @ 48" O.C. FOR HEIGHT FOR HEIGHT SEE CLG. PLANS SEE CLG. PLANS METAL FRAMING CHANNEL @ 16" O.C. (TYP.) FIRST LINE OF BRAC'G 4'-0" OR LESS FROM WALL BOUNDARY RUNNER CHANNEL @ 4'-0" O.C. (TYP) x;4'-0" TYP. x ;1 2 '-0 " T Y P . 1. AREAS SMALLER THAN 144 SQ. FT. AND WITH WALLS ON FOUR SIDES, EXTENDING TO THE STRUCTURE, DO NOT NEED TO BE BRACED. BOUNDARY WALLS MUST BE BRACED TOP AND BOTTOM INDEPENDENT OF CEILING. x;12'-0" TYP. A501 D1 NOTE: 9 0°FIRST LINE OF BRACING 6'-0" OR LESS FROM WALL BOUNDARY WALL SPLAY WIRE COMPRESSION POSTx;1 2 '-0 " (M A X .) NOTE: x ; 1 2 ' - 0 " ( M A X . ) x ;6 '-0 " M A X . CEILING SUSPENSION SYSTEM A501 D1 1. AREAS SMALLER THAN 144 SQ. FT. AND WITH WALLS ON FOUR SIDES EXTENDING TO THE STRUCTURE NEED NOT BE BRACED. BOUNDARY WALLS MUST BE BRACED TOP AND BOTTOM INDEPENDENT OF CEILING TO QUALIFY. 1. ALL SPLAY WIRES TO BE IN LINE WITH ATTACHED COMPONENT 2. ALL SPLAY WIRES TO BE TAUT AND TIED BOTH ENDS WITH MINIMUM OF THREE TURNS IN 1" OF RUN. 3. COMPLY WITH IBC 2012, ASTM C635, ASTM C636 AND CISCA STANDARDS 4. SPLAY WIRES SHALL ATTACH TO STRUCTURAL GIRDER OR JOIST ONLY, DO NOT ATTACH TO ROOF DECK. 5. METAL COMPRESSION POST (STRUT) FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. COMPRESSION POSTS & SPLAY WIRES TO BE INSTALLED EVERY 12' O.C. BOTH DIRECTIONS STARTING 6' FROM WALL. SEE COMPRESSION POST ALLOWABLE LENGTHS TABLE FOR SIZES. SEE DETAILS FOR TYPICAL BRACING. 6. ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. WHEN INTERMEDIATE SYSTEMS ARE USED, ATTACH NO. 12 GAGE HANGERS TO THE GRID MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. LIGHT FIXTURES WEIGHING LESS THAN 56 LBS. SHALL HAVE TWO NO. 12 GAGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. COMPLY WITH IBC 2012 7. ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED 20 LBS, AND SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS. TERMINALS OR SERVICES WEIGHING 20 LBS., BUT NOT MORE THAT 56 LBS., SHALL IN ADDITION HAVE TWO NO. 12 GAGE HANGERS CONNECTED TO THE CEILING SYSTEM HANGERS OR TO THE STRUCTURE ABOVE. TERMINALS OR SERVICES WEIGHING MORE THAN 56 LBS. SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. COMPLY WITH IBC 2012 8. ALL GRID SYSTEM IN SEISMIC ZONE D OR GREATER ARE REQUIRED TO BE HEAVY DUTY. REFER REQUIREMENTS TO ASCE 7 REQUIREMENTS. 9. CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHER PENETRATIONS, COORDINATE WITH SPECIFICATIONS. STRUCTURE SPLAY WIRE - SECURE TO STRUCTURE MAIN TEE CROSS TEE VERTICAL HANGER WIRE ADJACENT TO POST SPRING CLIP INSERTS IN HOLE IN POST STRUT ASSEMBLY TOP CLIP MECHANICALLY FASTENED TO DECK PER MANUFACTURERS RECOMMENDATIONS BULB CLIP ATTACHING COMPRESSION POST AND MAIN RUNNER MECHANICALLY FASTENED PER MANUFACTURERS RECOMMENDATIONS A FASTENER OR SPLAY WIRES MAYBE INSERTED INTO THE TAB OF THE POST AND THROUGH A CONVENIENCE HOLE IN THE MAIN TEE BULB COMPRESSION POST - INSTALL WITHIN 2" OF CROSS TEE INTERSECTION 45° OR LESS 45° OR LESS 45° OR LESS 45° OR LESS COMPRESSION POST ALLOWABLE LENGTHS TABLE 13/16" x 13/32" STRUT 19 GA MATERIAL TYP. ALLOWABLE LENGTH 24" 1 5/8" x 13/16" STRUT 12 GA 48" 13/16" x 13/16" STRUT 19 GA 54" 1 5/8" x 1" STRUT 12 GA 60" 3 5/8" x 1 1/4" STRUT 16 GA 82" 1 1/4" x 1 1/4" STRUT 14 GA 84" 1 5/8" x 1 3/8" STRUT 12 GA 96" 1 5/8" x 1 5/8" STRUT 12 GA 108" 1 5/8" x 2 7/16" STRUT 12 GA 120" NOTES: 1. THE INFORMATION PROVIDED IS FOR QUICK REFERENCE ONLY. OTHER RESTRICTIONS AND EXEMPTIONS MAY APPLY. 2. WALL MOLDING SHOULD NOT BE USED AS STRUTS. 3. A STRUCTURAL ENGINEER SHOULD BE CONSULTED FOR LENGTHS GREATER THAT 14'. NOTE: 12 GA. HANGER SEE SPECIFICATION 1 1/2" C.R. CHANNEL @ 48" O.C. 5/8" TYPE 'X' GYP BD 3/4" FURRING CHANNELS @ 24" O.C. C R O S S T E E H EAVY D UTY M AIN R U N N E R 12 GA. METAL HANGER WIRES H EAVY D UTY M AIN R U N N E R 4'-0" TYPICAL 3" M A X., TYP. SLACK WIRES #12 WIRE HANGER AT EACH CORNER OF FIXTURE (TYP.) INDEPENDENT OF CEILING SUPPORT SYSTEM 0' - 8" MAX0' - 8" MAX SCREW INTO MOLDING AT PERIMETER ANGLE MOLDING BY MANUFACTURER SCHED. GYPSUM PANEL DRYWALL MAIN RUNNER OR CROSS TEE HANGER 12 GA. @ 4'-0" O.C. MAX. 1. ALL HANGER WIRES TO BE IN LINE WITH ATTACHED COMPONENT OR SHALL BE COUNTERSLOPED NOT GREATER THAN 1/6 2. ALL HANGER WIRES TO BE TAUT AND TIED BOTH ENDS W/ MIN. OF 4 TURNS IN 1" OF RUN. NOTE: SCHEDULED WALL - SEE FLOOR PLAN 8" MAX8" MAX FASTENER ON ALL MEMBERS @ TWO ADJACENT WALLS ONLY PER MFG REQ. 2" CLIP ANGLE, ATTACH TO WALL SCHED. CEILING TILE CEILING GRID MAIN RUNNER OR CROSS TEE GRID PERPENDICULAR TO CEILING NOT ATTACHED TO CLOSURE ANGLE (TWO ADJACENT WALLS) HANGER 12 GA. @ 4'-0" O.C. MAX. 1. ALL HANGER WIRES TO BE IN LINE WITH ATTACHED COMPONENT OR SHALL BE COUNTERSLOPED NOT GREATER THAN 1/6 2. ALL HANGER WIRES TO BE TAUT AND TIED BOTH ENDS W/ MIN. OF 4 TURNS IN 1" OF RUN. NOTE: HANGER 12 GA. @ 4'-0" O.C. MAX. SCHEDULED GYP CEILING; RE: RCP REVEAL 4" 5" AXIOM TRIM FOR HEIGHT SEE CLG. PLANS FOR HEIGHT SEE CLG. PLANS SCHEDULED ACT CEILING, RE: RCP 5" AXIOM TRIM, BOD: ARMSTRONG AXIOM CLASSIC, WHITE 3/4" PLWOOD WITH WOOD VENEER FINISH, WV-01; RE: FINISH SCHEDULE, STOP 3" FROM BOTTOM OF DECK, FRONT PANEL TO EXTEND TO COVER RETURN PIECE AT BUTT JOINT PAINTED GYP AT REVEAL, PNT-05; RE: FINISH SCHEDULE SCHEDULED GYP CEILING, RE: RCP CORRIDOR A SIDESEATING A + B SIDE BOX HEADER (FILL HEADER CAVITY WITH INSULATION) GLASS, RE: SCHEDULE SEMI-RECESSED METAL U-CHANNEL 1" 2" SHEDULED WALL BLOCKING AS NEEDED EQ EQ FOR HEIGHT SEE CLG. PLANS FOR HEIGHT SEE CLG. PLANS ABUT GYPSUM POCKET AS CLOSE TO EXISTING FRAMING AS POSSIBLE SCHEDULED WALL; RE: DIMENSION PLAN FOR WALL TYPE MOTORIZED ROLLER SHADES, RE: CEILING PLAN + FINISH SCHEDULE (RS-01) SCHEDULED CEILING SYSTEM 1 1/2" STUD FRAMING, TIE INTO EXISTING WALL 5/8" GYPSUM BOARD PAINTED, PNT-02; RE: FINISH SCHEDULE ALUMINUM, POCKET ROLLER SHADE, REMOVEABLE TRIM KIT PROVIDED. COLOR TO MATCH PNT-01 PRE-FINISHED EDGE MOLDING BY MANUF. GLASS WELCOME ROOM SIDEWECLOME/INFO DESK SIDE 1. REFER TO AE100 SHEET SERIES FOR LOCATION OF WALL TYPES. 2. REFER TO SCHEDULES & DETAILS FOR FINISHES. 3. "LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF EACH WALL TYPE IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE THE EXACT CONSTRUCTION CONDITION. FIRE RATED WALLS ARE TO TERMINATE AT STRUCTURAL MEMBERS WITH A FIRE RESISTANT RATING. WHERE REQUIRED APPROPRIATE FRAMING AND GYP BOARD IS TO BE INSTALLED AND OFFSET AROUND STRUCTURAL MEMBERS OR OTHER OBSTRUCTIONS SUCH AS PIPING OR DUCTWORK, TO MAINTAIN THE FIRE RESISTANCE RATING. NON-RATED WALLS THAT CONTINUE TO STRUCTURE ARE TO TERMINATE AT PROPER LOCATIONS TO MAINTAIN THE INTENT OF THE CONTINUOUS PLANE OF ONE LAYER OF GYP BOARD AS A NOISE, SMOKE OR OTHER TYPE OF BARRIER. SEE HEAD AND SILL DETAILS FOR MORE INFORMATION. 4. ALL RATED WALLS SHALL BE CONSTRUCTED FIRST AND HAVE CONTINUITY PRIORITY OVER NON-RATED WALLS. SECONDARY, OR NON-RATED WALLS, ARE TO ABUTT, BUT NOT PENETRATE THE RATED WALLS. 5. FIRESTOPPING TO BE PROVIDED AT ALL PENETRATIONS THROUGH RATED WALLS AS SPECIFIED. COORDINATE WITH CODE PLANS. 6. APPROPRIATE SUBMITTAL INFORMATION MUST BE PROVIDED TO SUBSTANTIATE THAT THE MATERIALS AND ASSEMBLY USED BY THE CONTRACTOR HAVE BEEN TESTED BY A RECOGNIZED TESTING AGENCY TO MEET THE FIRE RESISTANCE RATING SCHEDULED ON THESE WALL TYPES. 7. ALL GYPSUM WALL BOARD MUST BE MOISTURE RESISTANT AT THE FOLLOWING LOCATIONS: a. TOILET ROOMS b. WET WALLS c. SHOWERS d. JANITOR'S CLOSETS 8. SOUND ATTENUATION BLANKETS SHALL EXTEND THE FULL HEIGHT OF THE WALLS. 9. SPACING OF THE METAL STUDS HAS NOT BEEN INDICATED ON THE WALL TYPES OR DETAILS. STUD SPACING IS TO BE DETERMINED BY THE HEIGHT OF THE PARTITION AS SHOWN IN THE TABLE BELOW. EACH STUD GOING TO STRUCTURE AND EXCEEDING ALLOWABLE HEIGHTS SHALL BE BRACED 45 DEGREES DIAGONALLY 12" ABOVE CEILING WITH EQUAL SIZE METAL STUDS. THIS TABLE IS TO BE USED FOR THE INTERIOR WALL TYPES ONLY AND DOES NOT APPLY TO EXTERIOR STUDS. STUDS IN DOUBLE STUD WALL CONFIGURATIONS ARE TO BE EVENLY STAGGERED RELATIVE TO THE ADJACENT STUD LAYOUT. 11. REFER TO INTERIOR DETAILS FOR ADDITIONAL INFORMATION. 12. UL DESIGN NUMBERS REFER TO FIRE RESISTANCE IN MOST CURRENT EDITION OF THE UL DIRECTORY. 13. IN PARTITIONS WITHOUT GYP BOARD ON BOTH SIDES, SUPPORT INSULATION WITH WIRE MESH TO STRUCTURE . 14. MAINTAIN 1/2" SPACE BETWEEN FLOOR SLAB AND BOTTOM OF GYP BOARD ON ALL WALLS. 15. STOP STUD 1" BELOW METAL RUNNER (TOP TRACK) TO ALLOW FOR VERTICAL EXPANSION; DO NOT ATTACH STUDS OR GYP BOARD TO TOP TRACK. 16. SEE STRUCTURAL DRAWINGS FOR EXTERIOR METAL STUD WALL SPACING, GUAGES, BRACING, AND CONNECTIONS. 17. PROVIDE NEOPRENE FLASHING BETWEEN ALL DISSIMILAR METALS, TYPICAL. 18. EXTERIOR SILL PLATES OR TRACKS TO BE SET IN 3 DISTINCT BEADS OF CONTINUOUS SEALANT. 19. INSTALLED/RE-INSTALLED CEILING SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION REQUIREMENTS. GENERAL NOTES -WALL TYPES FACING ON SIDES OF STUDS - HEIGHT IS DISTANCE FROM THE FLOOR TO THE STRUCTURE, NOT FLOOR TO CEILING - BRACING AT MIDPIOINT PREQUIRED FOR ALL WALLS OVER 12'-0" HIGH STUD SPAC'G ON CENTER STUD DEPTH 2 1/2" MAX. HT. STUD DEPTH 3 5/8" MAX. HT. STUD DEPTH 6" MAX. HT. 1 LAYER 5/8" GYP BD - 1 SIDE ONLY 1 LAYER 5/8" GYP BD - EACH SIDE 2 LAYER 5/8" GYP BD - EACH SIDE 16 24 16 24 16 24 11'-0" 9'-9" 12'-0" 10'-9" 14'-6" 12'-9" 16'-0" 13'-6" 16'-9" 13'-6" 14'-6" 12'-9" 16'-0" 13'-6" 20'-0" 15'-0" PLAN VIEW METAL STUD WALL NON-RATEDS#_ S2a 1 5/8" STEEL STUD, GYP BD ONE SIDE, SEE HEAD/SILL DETAIL "1" METAL STUD 1 OR 2 SIDE(S) OF 5/8" GYP BOARD, SEE WALL TYPE PLANS PROVIDE WIRE ATTACHED TO STUDS TO SUPPORT SOUND BATT INSULATION, WHEN LEFT EXPOSED R-13 SOUND BATT INSULATION, FULL HEIGHT TO DECK WHERE INDICATED ON WALL TYPES AND DIMENSION PLAN S4a 3 5/8" STEEL STUD, GYP BD ONE SIDE, SEE HEAD/SILL DETAIL "1" FOR AREAS ABOVE WINDOW AND CEILINGS AS INDICATED ON DIMENSION PLANS. THIS ALSO WILL OCCUR AT EXISTING WALLS THAT ARE ON THE PERIMETER OF THE WELCOME ROOM. S4a.1 3 5/8" STEEL STUD, GYP BD ONE SIDE WITH 1/2" FIRE TREATED SHEATHING (BACKING FOR TV) FIRE TREATED PLYWOOD SHEATHING (BACKING FOR TV) WHERE OCCURS, RE: DIMENSION PLAN & BELOW WALL TYPE PLAN VIEW WOOD VENNER WALL ON HAT CHANNELWV#_ WV1 7/8" STEEL HAT CHANNEL ON CMU WALL OR CONCRETE COLUMN, GYP BD, PLYWOOD WITH WOOD VENEER, RE: FINISH PLANS AND ELEVATIONS FOR ADDITIONAL WOOD VENEER LOCATIONS THAT ARE ADHERED TO GYP BOARD WALLS 5/8" GYP BOARD 7/8" HAT CHANNEL 3/4" PLWOOD WITH WOOD VENEER FINISH, WV-01; RE: FINISH SCHEDULE, STOP 3" FROM BOTTOM OF DECK WHEN ADJACENT TO OPENING IN THE CEILING EXISTING CMU WALL OR CONCRETE COLUMN CEILING AS SCHED. (HEIGHT VARIES, RE: REFL CEILING PLANS) ANCHOR TOP TRACK AS REQ'D FOR STRUCTURE TO WITHSTAND LOADING & DEFLECTION SCHEDULED WALL CONT. DEFLECTION TRACK PARTITION WALL HEAD/SILL DETAIL1 INNER SLIP TRACK METAL STUD BOTTOM TRACK ACOUSTIC SEALANT EACH SIDE FLOOR AS SCHEDULED 0' - 1 " M I N NOTE: DO NOT ATTACH GYP WALL BOARD OR WALL STUDS TO TOP TRACK ACOUSTIC SEALANT EACH SIDE GYP BOARD TO FOLLOW METAL DECK PROFILE, WHERE IT IS OPEN TO DECK IN THE ROOM. ACOUSTICAL SEALANT IS STILL REQUIRED 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A501 WALL ASSEMBLIES & CEILING DETAILS [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1 1/2" = 1'-0"B3 CEILING / SOFFIT DETAIL 1 1/2" = 1'-0"C3 CEILING/SOFFIT DETAIL (ACT-ACT) 1 1/2" = 1'-0"D4 CEILING/SOFFIT DETAIL (ACT-GYP) 12" = 1'-0"A2 SEISMIC BRAC'G - GYP BD CEILING 12" = 1'-0"A1 SEISMIC BRAC'G - LAYIN CEILING 1 1/2" = 1'-0"D1 SEISMIC BRACING DETAIL 3" = 1'-0"B2 SUSP. CEILING CHANNELS 1/64" = 1'-0"B1 TYP FIXTURE SUPPORT ISO 1 1/2" = 1'-0"C1 TYP SUSP. GYP. BD. CLG. - CLIP ANGLE 1 1/2" = 1'-0"C2 TYP. CEILING DETAIL - CLIP ANGLE 1 1/2" = 1'-0"B4 SUSP. GYP CEILING REVEAL 1 1/2" = 1'-0"A3 ACT CEILING REVEAL AT WOOD VENEER WALL 3" = 1'-0"C4 POCKET ROLLERSHADE CORE SIZE LEGEND C = CONCRETE WALLS, MASONRY S = STEEL STUDS W = WOOD STUDS G = GLAZING CORE MATERIAL LEGEND WALL TYPE HEAD CONDITION LEGEND IF NULL = TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF a = PARTITION EXTEND FROM FLOOR TO 6" ABOVE CEILING b = ACOUSTIC PARTITION c = 1 - HR FIRE RATED PARTITION d = 2 - HR FIRE RATED PARTITION STEEL STUDS WOOD STUDS MASONRY (WIDTH) BCONCRETE (WIDTH) 1 =A7/8" 2 = 1 5/8" 1 1/2" 3 = 2 1/2" 2 1/2" 4 = 3 5/8" 3 1/2" MASONRY SIZE 4" 5 = 6 = 6" 5 1/2" MASONRY SIZE 6" CONCRETE 6" 8 = 8" 7 1/4" MASONRY SIZE 8" CONCRETE 8" 10 = 9 1/4" MASONRY SIZE 10" CONCRETE 10" 12 = 11 1/4" MASONRY SIZE 12" CONCRETE 12" 14 = CONCRETE 14" 16 =MASONRY SIZE 16" SUPERSCRIPT NOTES - A - HAT CHANNEL FURRING IN LIEU OF METAL STUD B - IF WALL IS STRUCTURAL, DO NOT TAG WALL OR INCLUDE IN WALL TYPES LAYERS LEGEND NOTE: DO NOT USE THE FOLLOWING LETTERS: i, l, and o. a through e are Method Studio's Standard, f and above are user defined. SA = GYPSUM BOARD BOTH SIDE OF CORE SB = GYPSUM BOARD ONE SIDE OF CORE SC = GYPSUM BOARD, 2 LAYERS BOTH SIDES OF CORE SD = GYPSUM BOARD BOTH SIDES OF CORE, DOUBLE STUD SE = GYPSUM BOARD, 2 LAYERS BOTH SIDES OF CORE, DOUBLE STUD SF = GYPSUM BOARD, ONE LAYER CORE SIDE, ONE LAYER RESILIENT CHANNEL SIDE SG = GYPSUM BOARD, ONE LAYER CORE SIDE, ONE LAYER HAT CHANNEL SIDE SS = TYPE "X" GYPSUM BOARD, ONE LAYER CORE SIDE, 1" SHAFT LINER ST = TYPE "X" GYPSUM BOARD, 2 LAYERS CORE SIDE, 1" SHAFT LINER SU = TYPE "X" GYPSUM BOARD, 3 LAYERS CORE SIDE, 1" SHAFT LINER NON-FIRE RATED WALL TAG (description) SA6a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) FIRE RATED WALL TAG (description) FIRE RATING (IF APPLICABLE) 1SA6a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) GYP BOARD SCHEDULE 5/8" GYPSUM BOARD 5/8" TYPE X GYPSUM BOARD 5/8" MOISTURE RESISTANCE AND MOLD-RESITANT GYPSUM BOARD (TYPE X WHERE FIRE RATED) 5/8" GLASS MAT MOISUTRE AND MOLD-RESISTANT GYPSUM TILE BACKER (TYPE X WHERE FIRE RATED) 5/8" CEMENT BOARD ALL PARTITIONS UNLESS NOTED OTHERWISE BELOW FIRE RATED PARTITIONS WET OR HIGH HUMIDITY, HEAVY MOISTURE EXPOSURE AREAS SUCH AS TOILET ROOMS, SHOWERS, LOCKER ROOMS, AND JANITOR CLOSETS, EXCEPT WHERE WALL TILE OCCURS. USE AT KITCHEN WALLS FROM FLOOR TO 12" ABOVE COUNTERTOP, EXCEPT WHERE TILE BACKSPLASH OCCURS. LIMITED WATER EXPOSURE AREAS WHERE WALL TILE OCCURS, BEHIND FIBERGLASS SHOWER ENCLOSURES, AND KITCHEN WALLS FROM FLOOR TO 12" ABOVE COUNTERTOP WHERE TILE BACKSPLASH OCCURS WET OR HIGH HUMIDITY, HEAVY MOISTURE EXPOSURE AREAS WHERE WALL TILE OCCURS, EXCEPT AT BACKSPLASHES 1. AT FIRE RATED PARTITIONS WHERE CEMENT BOARD IS REQUIRED, PROVIDE CEMENT BOARD ON TOP OF TYPE X GYPSUM BOARD, OR PROVIDE A TESTED FIRE-RESISTANCE DESIGN THAT ALLOWS REPLACEMENT OF THE TYPE X GYPSUM BOARD WITH CEMENT BOARD. 2. REFER TO THE ENVIRONMENTAL CLASSIFICATIONS IN THE CURRENT EDITION OF THE TILE COUNCIL OF NORTH AMERICA HANDBOOK FOR CERAMIC, GLASS AND STONE TILE INSTALLATION. GYP BOARD NOTES 3 1 /4 " CORRIDOR A CEILING, RE: RCP FOR TYPE AND HEIGHT WOOD SLAT CEILING, SC-01; RE: FINISH SCHEDULE,, 10' AFF 5 " 1 " GYP CEILING CLOUD, STEEL FRAME CONSTRUCTION TO DECK, PAINTED FINISH AT ALL EXPOSED EDGES: PNT-01; RE: FINISH SCHDULE ALIGN 3 1/4" BLACK FELT FACTORY ATTACHED BLACK WOOD BACKER CABLE OR ALL THREAD, TO BE SUSPENDED VERTICALLY, NO HORIZONTAL (TYP) 5" AXIOM TRIM GYP CEILING @ WELCOME DESK, RE: RCP FOR TYPE, 10' AFF CNC CUT, 3/4" LETTERING, "BYU IDAHO", ADHERED TO FACE OF GYP CLOUD, OWNER TO PROVIDE FILES FOR PRODUCTION 5'-2 1/4"5" AXIOM TRIM MATCHING WOOD TRIM 4 1/2" 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A502 CEILING DETAILS [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set GENERAL NOTES - WALL TYPES 1 REFER TO A100's SHEET SERIES FOR LOCATION OF WALL TYPES 2 REFER TO SCHEDULES & DETAILS FOR FINISHES 3 "LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF EACH WALL TYPE IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE THE EXACT CONSTRUCTION CONDITION. RATED WALLS ARE TO TERMINATE AT STRUCTURAL MEMBERS WITH A FIRE RESISTANT RATING. WHERE REQUIRED APPROPRIATE FRAMING AND GYP BOARD IS TO BE INSTALLED AND OFFSET AROUND STRUCTURAL MEMBERS OR OTHER OBSTRUCTIONS SUCH AS PIPING OR DUCTWORK, TO MAINTAIN THE FIRE RESISTANCE RATING. NON-RATED WALLS THAT CONTINUE TO STRUCTURE ARE TO TERMINATE AT PROPER LOCATIONS TO MAINTAIN THE INTENT OF THE CONTINUOUS PLANE OF ONE LAYER OF GYP BOARD AS A NOISE, SMOKE OR OTHER TYPE OF BARRIER. SEE HEAD AND SILL DETAILS FOR MORE INFORMATION 4 ALL GYP BOARD SHALL BE 5/8", UNLESS NOTED OTHERWISE 5 ALL RATED WALLS SHALL BE CONSTRUCTED FIRST AND HAVE CONTINUITY PRIORITY OVER NON-RATED WALLS. SECONDARY, OR NON-RATED WALLS, ARE TO ABUTT, BUT NOT PENETRATE THE RATED WALLS 6 FIRESTOPPING TO BE PROVIDED AT ALL PENETRATIONS THROUGH RATED WALLS AS SPECIFIED. COORDINATE WITH CODE PLANS 7 APPROPRIATE SUBMITTAL INFORMATION MUST BE PROVIDED TO SUBSTANTIATE THAT THE MATERIALS AND ASSEMBLY USED BY THE CONTRACTOR HAVE BEEN TESTED BY A RECOGNIZED TESTING AGENCY TO MEET THE FIRE RESISTANCE RATING SCHEDULED ON THESE WALL TYPES 8 ALL GYPSUM WALL BOARD MUST BE MOISTURE RESISTANT AT THE FOLLOWING LOCATIONS: a. TOILET ROOMS b. WET WALLS c. SHOWERS d. JANITOR'S CLOSETS 9 SOUND ATTENUATION BLANKETS SHALL EXTEND THE FULL HEIGHT OF THE WALLS 10 SPACING OF THE METAL STUDS HAS NOT BEEN INDICATED ON THE WALL TYPES OR DETAILS. STUD SPACING IS TO BE DETERMINED BY THE HEIGHT OF THE PARTITION AS SHOWN IN THE TABLE BELOW. EACH STUD GOING TO STRUCTURE AND EXCEEDING ALLOWABLE HEIGHTS SHALL BE BRACED 45 DEGREES DIAGONALLY 12" ABOVE CEILING WITH EQUAL SIZE METAL STUDS. THIS TABLE IS TO BE USED FOR THE INTERIOR WALL TYPES ONLY AND DOES NOT APPLY TO EXTERIOR STUDS. STUDS IN DOUBLE STUD WALL CONFIGURATIONS ARE TO BE EVENLY STAGGERED RELATIVE TO THE ADJACENT STUD LAYOUT 11 REFER TO INTERIOR DETAILS FOR ADDITIONAL INFORMATION 12 UL DESIGN NUMBERS REFER TO FIRE RESISTANCE IN MOST CURRENT EDITION OF THE UL DIRECTORY 13 IN PARTITIONS WITHOUT GYP BOARD ON BOTH SIDES, SUPPORT INSULATION WITH WIRE MESH TO STRUCTURE 14 MAINTAIN 1/2" SPACE BETWEEN FLOOR SLAB AND BOTTOM OF GYP BOARD ON ALL WALLS 15 STOP STUD 1" BELOW METAL RUNNER (TOP TRACK) TO ALLOW FOR VERTICAL EXPANSION; DO NOT ATTACH STUDS OR GYP BOARD TO TOP TRACK 16 SEE STRUCTURAL DRAWINGS FOR EXTERIOR METAL STUD WALL SPACING, GAUGES, BRACING, AND CONNECTIONS 17 PROVIDE NEOPRENE FLASHING BETWEEN ALL DISSIMILAR METALS, TYPICAL 18 EXTERIOR SILL PLATES OR TRACKS TO BE SET IN 3 DISTINCT BEADS OF CONTINUOUS SEALANT 19 EIFS BASIS OF DESIGN - DRYVIT OUTSULATION PLUS MD OR EQUAL, SYSTEM SHALL BE INSTALLED PER MFR'S RECOMMENDED INSTALLATION DETAILS 1 1/2" = 1'-0"A1 "BYU IDAHO" CEILING CLOUD + WOOD SLAT CEILING AT WELCOME DESK 1 1 /2 " 3/4"3/4" 1'-0" WOOD SLAT, 8 SLATS PER 1', WS-01; RE: FINISH SCHEDULE FACTORY ATTACHED WOOD BACKER O P E N A R E A 8 1 /2 " 5 3/4" 3 6 " 4 " 3 0 " 3" 4 " FINISHED FLOOR MILLWORK AS SCHEDULED; RE: ELEVATIONS FOR TYPE AND FINISH QUARTZ COUNTERTOP WITH 3/4" PLYWOOD SUBSTRATE, ST-01; RE: FINISH SCHEDULEQUARTZ COUNTERTOP WITH 3/4" PLYWOOD SUBSTRATE, ST-01; RE: FINISH SCHEDULE WB-02; RE: FINISH SCHEDULE DRAWER/DOOR PULL - AMEROCK EDGE PULL 3.75", SATIN NICKEL BLOCKING AS REQUIRED BRUSHED ALUMINUM LETTERING MOUNTED TO FACE, OWNER PROVIDED /OWNER INSTALLED MOCKETT SQUARE DESK GROMMET, MAX2/A, 3 15/16", SATIN ALUMINUM, CENTERED AT EACH WORK SPACE FINISHED FLOOR 1/2" 32" 1 1 /2 " MILLWORK AS SCHEDULED, RE: ELEVATIONS FOR TYPE AND FINISH QUARTZ COUNTERTOP WITH PLYWOOD SUBSTRATE, ST-01; RE: FINISH SCHEDULE WOOD SLAT FINISH AT FACE, WS-01; RE: FINISH SCHEDULE PLYWOOD SUBSTRATE WITH WOOD VENEER FINISH WV-01; WB-02; RE: FINISH SCHEDULE DRAWER/DOOR PULL -AMEROCK EDGE PULL 3.75", SATIN NICKEL 3 0 " BLOCKING AS REQUIRED TRANSACTION TOP, WHERE OCCURS COUNTERTOP: 1 1/2" THICK, SQUARE EDGE - SCRIBE TIGHTLY TO WALL, 3/4" PLYWOOD SUBSTRATE, RE: ELEVATIONS FOR FINISH TYPE REFER TO FLOOR PLAN FOR WALL TYPES DRAWER/DOOR PULL -AMEROCK EDGE PULL 3.75", SATIN NICKEL CABINET DOOR: 3/4" CORE, SQ. EDGES. RE: ELEVATIONS FOR FINISH INTERIOR CABINET: 3/4" CORE FACED W/ WHITE MELAMINE STANDARD TOE KICK HEIGHT IS 4"H, PROVIDE 2-1/2" H TOE KICK AT DESK HEIGHT, MATCH CABINET MATERIAL PROVIDE BLOCKING AS REQ'D 24" BACKSPLASH AT WET AREAS ONLY U.N.O. RE: ELEVATIONS ADJUSTABLE SHELF VA R I E S , R E : E L E V A T I O N 2 1/2" CNC CUT MDF LETTERS, PAINTED FINISH, SCRIBED TIGHTLY AROUND 3/4" WOOD VENEER FRAME WOOD VENEER FRAME, WV-01; RE: FINISH SCHEDULE WOOD VENEER WALL, WV-01; RE: FINISH SCHEDULE 3/4" 3 /4 " 4" 4 '-1 0 1 /2 " WALL BASE, WB-02, RE: FINISH SCHEDULE FINISHED FLOOR MILLWORK U CHANNEL, BOD: FRY REGLET, MWU 7550, ANODIZED ALUMINUM WOOD SLAT WALL, WS-01; RE: FINISH SCHEDULE 3/4" PLYWOOD WITH WOOD VENEER FINISH, WV-01; RE: FINISH SCHEDULE WALL AS SCHEDULED, RE: DIMENSION PLAN FLAT PANEL DISPLAY TV, OWNER PROVIDED, CONTRACTOR INSTALLED 3 /4 " 3 /4 " 3/4" PLYWOOD TV FRAME WITH WOOD VENEER FINISH, WV-01; RE: FINISH SCHEDULE, FINISH AT ALL EXPOSED EDGES, SQUARE EDGES, MITERED AT JOINTS 3/4" PLYWOOD TV FRAME WITH WOOD VENEER FINISH, WV-01; RE: FINISH SCHEDULE, FINISH AT ALL EXPOSED EDGES, SQUARE EDGES, MITERED AT JOINTS WALL AS SCHEDULED, RE: DIMENSION PLANS WOOD VENEER WALL, WV-01; RE: FINISH SCHEDULE WOOD SLAT, WS-01; RE: FINISH SCHEDULE, RE: B1:A571 FOR TYPICAL WOOD SLAT DETAIL WOOD VENEER TV FRAME, WV-01; RE: FINISH SCHEDULE, SQUARE EDGES, MITERED JOINTS MIRRORED FOR BOTTOM OF FRAME WALL AS SCHEDULED, RE: DIMENSION PLANS WOOD VENEER WALL, WV-01; RE: FINISH SCHEDULE WOOD SLAT, WS-01; RE: FINISH SCHEDULE, RE: B1:A571 FOR TYPICAL WOOD SLAT DETAIL 4 " 3/4" WOOD VENEER TV FRAME, WV-01; RE: FINISH SCHEDULE, SQUARE EDGES, MITERED JOINTS MIRRORED FOR RIGHT SIDE OF FRAME 18" DRAWER/DOOR PULL -AMEROCK EDGE PULL 3.75", SATIN NICKEL CAM LOCK AT ALL DOORS, ALL KEYED SIMILAR, CAM LOCK AT ALL DOORS, ALL KEYED SIMILAR, CABINET DOOR: 3/4" CORE, SQ. EDGES, WOOD VENEER FINISH, WV-01; RE: FINISH SCHEDULE, DOOR TO BE FLUSH WITH SURROUNDING WOOD VENEER WALL INTERIOR CABINET: 3/4" CORE FACED W/ WHITE MELAMINE PROVIDE BLOCKING AS REQ'D ADJUSTABLE SHELVES 4" BASE, WB-02; RE: FINISH SCHEDULE, MILLWORK U CHANNEL, BOD: FRY REGLET, MWU 7550, ANODIZED ALUMINUM FINISHED FLOOR WALL BEYOND WOOD VENEER WALL PANEL, WV-01; RE: FINISH SCHEDULE 1 /4 " 5 1/2" 5 " 1 '-9 1 /2 " 5 3 /4 " 4 3 /4 " ELECTRIC FIREPLACE: REGAL FLAME, GOTHAM 72", BUILT-IN, VENTLESS, WALL MOUNTED, #LW2072WS, - PEBBLE STYLE WOOD SLAT WALL, WS-01; RE: FINISH SCHEDULE 4" BASE, WB-02; RE: FINISH SCHEDULE, MILLWORK U CHANNEL, BOD: FRY REGLET, MWU 7550, ANODIZED ALUMINUM A571 B5 1 1/2" WOOD VENEER, WV-01; RE: FINISH SCHEDULE BLOCKING AS NEEDED WALL AS SCHEDULED 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A571 INTERIOR DETAILS [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 3" = 1'-0"B1 TYPICAL WOOD WALL SLATS 1" = 1'-0"A1 WELCOME/HELP DESK SECTION - HIGH 1" = 1'-0"A2 WELCOME/HELP DESK SECTION - LOW 1" = 1'-0"A3 TYPICAL BASE CABINET 1 1/2" = 1'-0"A4 "WELCOME" AT VERTICAL TV WOOD WALLS 1" = 1'-0"A6 WOOD FRAMED TV AT WOOD VENEER WALL 1 1/2" = 1'-0"B5 WOOD SLAT WALL WITH TV FRAME - DETAIL 1 1 1/2" = 1'-0"A5 WOOD SLAT WALL WITH TV FRAME - DETAIL 2 1" = 1'-0"B2 RECESSED TALL CABINET 1 1/2" = 1'-0"B4 FIREPLACE SECTION DETAIL ALUMINUM, FULL LITE D1 S E E S C H E D . SEE SCHED. 6 " 1 0 " C .L . O F H A R D W A R E 3 ' - 4 " 6" G1 WOOD FLUSH D2 S E E S C H E D . SEE SCHED. C .L . O F H A R D W A R E 3 ' - 4 " 6" F1 F2 2"SEE SCHED.2" SE E D O O R S C H E D U L E 2" ALUM STOREFRONT 2"SEE SCHED. SE E D O O R S C H E D U L E 2" 1' - 8 " 2" G1 FIELD VERIFY 10'-4" EQ EQ G1 C1 A601 D1 A601 A1 A601 HOLLOW METAL 2 " 9 '-0 " 2"SEE SCHED. SE E D O O R S C H E D U L E 2" 1' - 8 " 2" G1 FIELD VERIFY 12'-2 1/2" EQEQ G1 C1 A601 D1 A601 A1 A601 2 " 9 '-0 " F3 ALUM STOREFRONT G1 G1 G1 SCHEDULED WALL, SEE WALL TYPES INSULATION TO EXTEND TO DECK STOREFRONT SYSTEM, RE: SCHEDULE & WINDOW TYPES SEALANT BOTH SIDES TYP. SHIM BOX HEADER GYP BOARD "J" BEAD (BOTH SIDES) IN T E R I O R S I D E O F W E L C O M E R O O M NOTE: ALIGN FACE OF STOREFRONT FRAME TO FACE OF FINISH WALL TYPE S3b RE: DETAIL C4/A501 FOR ROLLER SHADE AREAS SCHEDULED WALL GLAZING, SEE WINDOW TYPES & GLAZING SCHEDULE SEALANT BOTH SIDES TYP. STOREFRONT SYSTEM SHIM INTERIOR SIDE OF WELCOME ROOM GYP BOARD NOTE: ALIGN FACE OF STOREFRONT FRAME TO FACE OF FINISH WALL BACKER ROD & SEALANT BOTH SIDES TYPICAL SHIM SPACE FINISHED FLOOR WINDOW / STOREFRONT SYSTEM, RE: SCHEDULE & WINDOW TYPES SEALANT, BOTH SIDES DOUBLE END STUD FRAME, RE DOOR SCHEDULE SCHEDULED WALL DOOR AS SCHEDULED DRYWALL "J" MOLDING GYP BOARD RETURN TO FRAME (WHERE APPLIES) SHIM GENERAL NOTES -STOREFRONT A. WINDOW TYPES KEY: SF# (STORE FRONT SYSTEM) : 2" X 4 1/2" (B.O.D. = KAWNEER TRIFAB VERSAGLAZE 451T) B. UNLESS OTHERWISE SPECIFIED, MAX GLASS PANEL WIDTH SIZE SHALL NOT BE GREATER THAN 5'-0", ALL GLASS PANEL WIDTHS SHALL BE EQUAL. C. OVERALL DIMENSIONS ARE FROM OUTSIDE FACE OF MULLION; INTERIOR/FIELD DIMENSIONS ARE TO CENTERLINE OF MULLION D. PROVIDE TEMPERED GLASS AT ALL CODE REQUIRED LOCATIONS E. CONTRACTOR SHALL BE THE RESPONSIBLE PARTY FOR THE ENERGY PERFORMANCE RATINGS OF THE FENESTRATION SYSTEM IN ACCORDANCE WITH THE NATIONAL FENESTRATION RATING COUNCIL REQUIREMENTS. CONTRACTOR SHALL ACQUIRE LABEL CERTIFICATES FOR SITE-BUIT GLAZING SYSTEMS AS REQUIRED BY THE CODE OFFICAL. CONTRACTOR SHALL HAVE THE OPTION OF SELECTING EITHER THE "CERTIFIED PRODUCT" OR "CERTIFIED PROJECT PATH" PER NFRC 100 FG1 FG2 FRAMELESS GLAZED WALL 9' - 0 " A3 A601 A2 A601 C4 A501 A4 A601 FRAMELESS GLAZED WALL 9' - 0 " EQ EQ EQ A3 A601 A2 A601 C4 A501 G2 A4 A601 FIELD VERIFY 10'-2 1/2" FIELD VERIFY 21'-11 1/2" EQ EQ EQ EQ EQ EQ FG3 FRAMELESS GLAZED WALL 9' - 0 " EQ EQ EQ A3 A601 A2 A601 A3 A501 A4 A601 FIELD VERIFY 13'-2 1/4" FG4 FRAMELESS GLAZED WALL 9' - 0 " EQ EQ EQ A3 A601 A2 A601 A3 A501 A4 A601 FIELD VERIFY 10'-11" G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 2" G1 FIELD VERIFY 12'-2 1/2" EQEQ G1 C1 A601 D1 A601 A1 A601 2 " 9 '-0 "G1 G1 EQ EQ 2"2"2" SF1 ALUM STOREFRONT WALL SIM SIM GLASS, RE: SCHEDULE METAL U-CHANNEL. PROVIDE MATCHING ALUMINUM STRIP TO COVER EXISTING TRAVERTINE WHERE OCCURS EXISTING FLOOR. TRAVERTINE UNDER TRACK, AND CONCRETE ON WELCOME ROOM SIDE2" 1" SHEDULED WALL GLASS, RE: SCHEDULE CL 2 " SEMI-RECESSED METAL U-CHANNEL INTERIOR ROOM SIDE OF SPACE GLAZING 3/16" MAX CLEAR SEALANT, CONT. EXISTING CMU WALL DOOR PAINTED HOLLOW METAL FRAME. HAT CHANNEL, GYP BOARD AND PLYWOOD W/ VENEER. RE: DIMENSION PLANS AND WALL TYPES L5X5X1/4 ANGLE AS LINTEL FOR DOOR OPENING. 4" BEARING ON EACH SIDE. SEALANT EACH SIDE EXISTING CMU WALL DOOR PAINTED HOLLOW METAL FRAME. HAT CHANNEL, GYP BOARD AND PLYWOOD W/ VENEER. RE: DIMENSION PLANS AND WALL TYPES SEALANT EACH SIDE 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A601 DOOR SCHEDULE [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set DOOR SCHEDULE Type Room DOOR DIMENSIONS DOOR FRAME Card Access Panic Hardware Electrified Hardware Hardware Set CommentsWidth Height Thickness Door Type Door Material Door Finish Frame Type Frame Material Frame Finish 3A WELCOME / HELP DESK 3' - 0" 7' - 0" D1 ALUM ANODIZED F2 ALUMINUM ANODIZED Yes Yes A3 3B WELCOME ROOM 3' - 0" 7' - 0" D1 ALUM ANODIZED F2 ALUMINUM ANODIZED Yes A1 3D WELCOME ROOM 3' - 0" 7' - 0" D1 ALUM ANODIZED F3 ALUMINUM ANODIZED Yes Yes Yes A2 4 WELCOME ROOM 3' - 6" 7' - 0" 0' - 1 3/4" D2 WOOD STAINED F1 HM HM Yes Yes 01 PAINTED TO MATCH WOOD 1/4" = 1'-0"C4 DOOR TYPES 1/4" = 1'-0"C2 FRAME TYPES 3" = 1'-0"A601D1INTERIOR STOREFRONT HEAD TYP 3" = 1'-0" A601 C1 INTERIOR STOREFRONT JAMB 3" = 1'-0" A601 A1 INTERIOR STOREFRONT SILL AT FLOOR TYP 3" = 1'-0"D2 FRAMED WALL - SF DOOR JAMB GLAZING/SPANDREL SCHEDULE G1 1" DOUBLE GLAZED INSULATED - TEMPERED G2 1/2" CLEAR GLAZING - TEMPERED 1/4" = 1'-0"B1 WINDOW TYPES 3" = 1'-0"A3 FRAMELESS GLAZING - SILL DETAIL 3" = 1'-0"A2 FRAMELESS GLAZING - JAMB DETAIL 3" = 1'-0"A4 FRAMELESS GLAZING - BUTT DETAIL GENERAL NOTES - DOORS 1 ALL HOLLOW METAL FRAMES AND DOORS ARE TO BE PAINTED TO MATCH ADJACENT WALL FINISH, UNLESS NOTED OTHERWISE 2 ALL INTERIOR HOLLOW METAL FRAME WIDTHS ARE TO MATCH WALL WIDTHS; COORDINATE WITH VERTICAL ASSEMBLY TYPES 3 WOOD GRAIN DIRECTION TO BE VERTICAL, UNLESS NOTED OTHERWISE 4 FINISH OF METAL FRAMES ADJACENT TO METAL PANEL TO MATCH METAL PANEL COLOR, UNLESS NOTED OTHERWISE 5 COLOR TRANSITIONS TO OCCUR AT INSIDE OF FRAME STOP 6 DOORS SERVING SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE SHALL NOT BE PROVIDED WITH A LATCH OR LOCK OTHER THAN PANIC HARDWARE. SEE DOOR HARDWARE SPECIFICATIONS 3" = 1'-0"D3 HM FRAME HEAD DETAIL 3" = 1'-0"D4 HM FRAME JAMB DETAIL 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A611 FINISH SCHEDULES [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set SCEDULED MATERIALS AND FINISHES SHALL BE USED FOR BASIS OF DESIGN U.N.O. *MS_FINISH SCHEDULE CODE PRODUCT TYPE MANUFACTERER STYLE COLOR DIVISION FINISH NOTES/ REMARKS SPECIFICATION DIVISION 06 - WOODS, PLASTICS & COMPOSITES PL-01 PLASTIC LAMINATE WILSONART STANDARD HPL, MATTE FINISH LANDMARK WOOD 7981K-12 DIVISION 06 - WOODS, PLASTICS & COMPOSITES BASE CABINETS GRAIN TO RUN VERTICAL, MATCHING EDGEBANDING WS-01 WOOD SLAT GEOMETRIK OAK WHITE RIFT CUT, WITH CLEAR STANDARD CLEAR FINISH DIVISION 06 - WOODS, PLASTICS & COMPOSITES INSTALLATION PER MFGR INSTALLATION INSTRUCTIONS WG-2448-8WB, 1 1/2"X3/4", 8 BLADES PER 1', WV-01 WOOD VENEER RIFT CUT OAK WITH CLEAR FINISH STAIN/ SPECIES/ FINISH TO COORDINATE WITH EXISTING DOORS, PHYSICAL SAMPLE TO BE PROVIDED AND APPROVED BY ARCHITECT DIVISION 06 - WOODS, PLASTICS & COMPOSITES DIVISION 09 - BASE & TRANSITIONS WB-01 RUBBER WALL BASE BURKE 4" TRADITIONAL 505 TRUE BLUE DIVISION 09 - BASE & TRANSITIONS WB-02 WOOD BASE RIFT CUT WHITE OAK WITH CLEAR FINISH DIVISION 09 - BASE & TRANSITIONS 4", 3/4" THICK WB-03 CARPET BASE INTERFACE DIVISION 09 - BASE & TRANSITIONS EXISTING CARPET BASE, PATCH AS NEEDED, OWNER PROVIDED; OWNER INSTALLED DIVISION 09 - CEILINGS ACP-01 ACOUSTICAL CEILING PANEL USG 2110 WHITE DIVISION 09 - CEILINGS INSTALLATION PER MFGR INSTALLATION INSTRUCTIONS 24" X 24" SC-01 SPECIALTY CEILING GEOMETRIK OAK WHITE RIFT CUT, STANDARD CLEAR FINISH DIVISION 09 - CEILINGS INSTALLATION PER MFGR INSTALLATION INSTRUCTIONS, NO REVEALS AT PANEL JOINTS WG-44104-FWB, 3 1/4" X 1 3/8", 4 BLADES PER 1', SUSPENSION SYSTEM; T-BAR GRID SYSTEM, MATCHING WOOD TRIM AT OUTSIDE EDGES DIVISION 09 - FLOORS CPT-01 CARPET TILE INTERFACE (EXISTING; CAMPUS STANDARD) URBAN GRID 9838 STEEL DIVISION 09 - FLOORS 2. GENERAL CAPRET FLOORING 1C X 50CM, OWNER PROVIDED; OWNER INSTALLED; RE: FINISH PLANS FOR LOCATIONS CPT-02 CARPET TILE INTERFACE (CAMPUS STANDARD) UR501 127340AK0 103616 NAVY DIVISION 09 - FLOORS 2. GENERAL CAPRET FLOORING 25CM X 1 M, OWNER PROVIDED; OWNER INSTALLED; RE: FINISH PLANS FOR LOCATIONS AND DIRECTION OF FLOORING DIVISION 09 - PAINT & WALLCOVERING PNT-01 FIELD WALL PAINT SHERWIN-WILLIAMS CASHMERE GALE FORCE SW 7605 DIVISION 09 - PAINT & WALLCOVERING MEDIUM LUSTRE PNT-02 FIELD CEILIING PAINT SHERWIN-WILLIAMNS SW7565 OYSTER BAR DIVISION 09 - PAINT & WALLCOVERING FLAT FINISH PNT-03 WALL PAINT SHERWIN-WILLIAMS CASHMERE SW 7565 OYSTER BAR DIVISION 09 - PAINT & WALLCOVERING MEDIUM LUSTRE PNT-04 ACCENT PAINT SHERWIN WILLIAMS CASHMERE DORIAN GRAY SW 7017 DIVISION 09 - PAINT & WALLCOVERING MEDIUM LUSTRE PNT-05 EXPOSED CEILING PAINT SHERWIN WILLIAMS IRON ORE SW 7069 DIVISION 09 - PAINT & WALLCOVERING FLAT DIVISION 10 - SPECIALTIES CG-01 CORNER GUARD BYUI CAMPUS STANDARD DIVISION 10 - SPECIALTIES TO COORDINATE LOCATIONS WITH ARCHITECT, NOT AT WOOD VENEER WALLS DIVISION 12 - FURNISHINGS ST-01 QUARTZ COUNTERTOP DALTILE ONE QUARTZ WOVEN WOOL DIVISION 12 - FURNISHINGS - RS-01 ROLLER SHADES DRAPER SINGLE SHADE, 1% OPENNESS, MOTORIZED MATCH HARDWARE COLOR TO PNT-01, FABRIC: MERMET E SCREEN PEARL GRAY 1% DIVISION 12 - FURNISHINGS TYPE "D" POCKET HEADBOX RE F . A 1 2 3 4 5 6 7 B C D E 224.67 SF SEATING A 5 306.73 SF SEATING B 6 714.25 SF WELCOME / HELP DESK 7 1,018.92 SF WELCOME ROOM 3 1,036.53 SF CORRIDOR A 10 187.46 SF STORAGE 4 324.13 SF EXISTING STORAGE 9 SEATING WILL NEED TO ACCOMODATE 84 CHAIRS 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 03/25/2022 A801 FURNITURE PLAN [ SET PROJECT INFO NUMBER PARAMETER ]March 25, 2022 [ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ] BYUI MANWARING WELCOME CENTER REMODEL Bid Set 1/4" = 1'-0"A1 LEVEL 1 FURNITURE PLAN NOTE: FURNITURE IS OWNER FURNISHED AND OWNER INSTALLED. THE FOLLOWING LAYOUT IS TO HELP COORDINATE INFRASTURCTURE AND SUPPORT FOR THE FURNITURE. UPDATES WILL BE PROVIDED BY BYUI AT A LATER DATE. ar ^ i = a r ` q = s ^ o f ^ _ i b = s l i r j b = E a s ^ s F MINIMUM SY M B O L T I T U S C F M T I T U S O P E R A T I N G R E M A R K S SIZ E R A N G E M O D E L S T A T I C I N . W . C . DV A V R _ 6 3 0 0 - 3 9 9 D E S V 1 . 0 DV A V R _ 8 4 0 0 - 5 9 9 D E S V 1 . 0 DV A V R _ 1 0 8 5 0 - 9 9 9 D E S V 1 . 0 DV A V R _ 1 2 1 0 0 0 - 1 3 4 9 D E S V 1 . 0 DV A V R _ 1 4 1 3 5 0 - 1 9 9 9 D E S V 1 . 0 DV A V R _ 1 6 2 0 0 0 - 2 3 9 9 D E S V 1 . 0 DV A V R _ 2 4 x 1 6 2 4 0 0 - 4 8 0 0 D E S V 1 . 0 ar ^ i = a r ` q = s ^ o f ^ _ i b = s l i r j b = E a s ^ s F kbt=as^s=_lu bu f p q f k d = a s ^ s = _ l u b p BA L A N C E M A X . M I N I M U M C O L D H O T C O L D M I N . H O T M I N . SY M B O L A I R F L O W A I R F L O W A I R F L O W T I T U S T I T U S I N L E T I N L E T R E M A RKS CL G . C F M H T G . C F M C F M S I Z E S I Z E S I Z E I N . S I Z E I N . DV A V - 2 6 6 E 4 5 0 3 2 5 3 2 5 8 6 8 6 DV A V - 2 6 6 B 1 , 3 0 0 3 1 0 3 1 0 1 4 1 0 1 4 1 0 S H O W N F O R B A L A N C E C F M DV A V - 2 6 6 D 1 , 0 1 0 5 9 0 5 9 0 1 0 6 1 0 6 S H O W N F O R B A L A N C E C F M DV A V - 2 6 8 A 1 9 0 1 0 0 1 0 0 8 6 8 6 S H O W N F O R B A L A N C E C F M DV A V - 2 6 9 C 4 0 0 1 1 0 1 1 0 6 6 6 6 S H O W N F O R B A L A N C E C F M DV A V - H 2 N 5 7 0 1 5 0 1 5 0 1 0 6 1 0 6 S H O W N F O R B A L A N C E C F M do f i i b = ^ k a = a f c c r p b o = p ` e b a r i b pv j _ l i = i b d b k a (E ) CH W S CH W R HW R HW S FS RD FD D T SS. F . D . A. D . H. D . RI S E 24 " x 1 2 " 24 " x 1 8 " HO T W A T E R S U P P L Y CO L D W A T E R CH I L L E D W A T E R R E T U R N CH I L L E D W A T E R S U P P L Y HO T W A T E R R E T U R N SO I L O R W A S T E DO M E S T I C H O T W A T E R EX I S T I N G DO M E S T I C H O T W A T E R R E C I R C U L A T I N G VE N T CO N C E N T R I C R E D U C E R TH E R M O M E T E R GA U G E W I T H G A U G E C O C K GA U G E C O C K EC C E N T R I C R E D U C E R TH E R M O M E T E R O R G A U G E W E L L SA F E T Y O R R E L I E F V A L V E SO L E N O I D V A L V E GL O B E V A L V E PI P E G U I D E PI P E A N C H O R BL I N D F L A N G E PR E S S U R E / T E M P E R A T U R E T E S T P L U G ( P E T E ' S P L U G ) FL O W C O N T R O L L E R O R B A L A N C E V A L V E FL O O R D R A I N , F L O O R S I N K O R R O O F D R A I N PR E S S U R E R E D U C I N G V A L V E - ( P R V ) ST E A M T R A P DIR T L E G DR A I N ST R A I N E R CH E C K V A L V E BU T T E R F L Y V A L V E PL U G V A L V E CA P DE S C R I P T I O N SY M B O L EX H A U S T G R I L L E OP P O S E D B L A D E D A M P E R PA R A L L E L B L A D E D A M P E R BR A N C H D U C T T A K E - O F F SP I N - I N F I T T I N G TH E R M O S T A T TE M P E R A T U R E S E N S O R DR O P I N P I P E VA L V E I N R I S E BA L L V A L V E GA T E V A L V E 2 W A Y C O N T R O L V A L V E 3 W A Y C O N T R O L V A L V E CO N T R O L V A L V E ( P L A N V I E W ) RIS E I N P I P E UN I O N NE W C O N N E C T I O N FL A T O V A L ( C R O S S S E C T I O N ) RO U N D D U C T ( C R O S S S E C T I O N ) SU P P L Y D U C T ( C R O S S S E C T I O N ) HA N D D A M P E R SU P P L Y A I R D I R E C T I O N TU R N I N G V A N E S I N D U C T AC C E S S D O O R F O R F I R E D A M P E R AC C O U S T I C A L L I N I N G I N D U C T DR O P O R R I S E I N S U P P L Y D U C T SU P P L Y D I F F U S E R CO M B I N A T I O N S M O K E / F I R E D A M P E R RIS E O R D R O P I N R O U N D O V A L D U C T IN S I D E C L E A R D I M E N S I O N I N I N C H E S DU C T S I Z E , I N S I D E C L E A R D I M E N S I O N I N I N C H E S RE T U R N A I R O R E X H A U S T D U C T ( C R O S S S E C T I O N ) RE T U R N A I R O R E X H A U S T D I R E C T I O N RE T U R N A I R G R I L L E DU C T R I S E DE S C R I P T I O N SY M B O L SY M B O L FA C E P A N E L SIZ E TY P E KRUEGER MODELREMARKS S- 1 2 4 " x 2 4 " C E I L I N G D I F F U S E R - L A Y - I N 1 4 0 0 - S- 2 2 4 " x 2 4 " C E I L I N G D I F F U S E R - G Y P . C E I L I N G 1 4 0 0 - R- 1 2 4 " x 2 4 " P E R F O R A T E D - L A Y - I N C E I L I N G 6 4 9 0 - R- 2 1 2 " x 2 4 " P E R F O R A T E D - L A Y - I N C E I L I N G 6 4 9 0 - 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 MECHANICAL SCHEDULES AND SYMBOL LEGEND12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Set 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 B BB B C CC C D DD D E EE E 9 EX I S T I N G S T O R A G E 4 ST O R A G E 1 11 1 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 1 11 1 1 11 1 1 11 1 6 66 6 3 33 3 7 77 7 3 33 3 1 11 11111 1 11 1 1 11 1 1 11 1 5 55 5 5 55 5 6 66 64444 6 66 6 1 11 1 1 11 1 3 33 3 3 33 3 6 66 6 1 11 1 1 11 1 4 44 4 3 33 3 2 22 2 2 22 2 4 44 4 3 33 3 3 33 3 3 33 3 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 dbkbo^i=klqbp A.A.A.A.FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PERIOD. PERIOD. PERIOD. PERIOD. PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR PATCHWORK. PATCHWORK. PATCHWORK. PATCHWORK. INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING UNITS. UNITS. UNITS. UNITS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING COMPONENTS. COMPONENTS. COMPONENTS. COMPONENTS. PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND TERMINATED.TERMINATED.TERMINATED.TERMINATED.B.B.B.B.C.C.C.C.D.D.D.D.E.E.E.E.F.F.F.F.G.G.G.G.H.H.H.H.I.I.I.I.J.J.J.J.K.K.K.K.L.L.L.L.M.M.M.M.3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 SECOND LEVEL MECHANICAL DEMOLITION PLAN12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Set SC A L E : SC A L E : SC A L E : SC A L E : MD 1 0 1 MD 1 0 1 MD 1 0 1 MD 1 0 1 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" pb ` l k a = i b s b i = j b ` e ^ k f ` ^ i ab j l i f q f l k = m i ^ k 1 11 1 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 ao^tfkd=klqbp NOTE #DESCRIPTION 1 11 1 REMOVE EXISTING DIFFUSER AND A PORTION OF REMOVE EXISTING DIFFUSER AND A PORTION OF REMOVE EXISTING DIFFUSER AND A PORTION OF REMOVE EXISTING DIFFUSER AND A PORTION OF THE EXISTING DUCTWORK IN ORDER TO THE EXISTING DUCTWORK IN ORDER TO THE EXISTING DUCTWORK IN ORDER TO THE EXISTING DUCTWORK IN ORDER TO ACCOMMODATE NEW WORK.ACCOMMODATE NEW WORK.ACCOMMODATE NEW WORK.ACCOMMODATE NEW WORK.2 22 2 E X I S T I N G D I F F U S E R T O R E M A I N . EXISTING DIFFUSER TO REMAIN.EXISTING DIFFUSER TO REMAIN.EXISTING DIFFUSER TO REMAIN.3 33 3 R E M O V E E X I S T I N G R E T U R N A I R G R I L L E A N D S O U N D REMOVE EXISTING RETURN AIR GRILLE AND SOUND REMOVE EXISTING RETURN AIR GRILLE AND SOUND REMOVE EXISTING RETURN AIR GRILLE AND SOUND BOOT.BOOT.BOOT.BOOT.4 44 4 R E M O V E E X I S T I N G S . A . D U C T W O R K A S S H O W N . REMOVE EXISTING S.A. DUCTWORK AS SHOWN.REMOVE EXISTING S.A. DUCTWORK AS SHOWN.REMOVE EXISTING S.A. DUCTWORK AS SHOWN.5 55 5 R E M O V E E X I S T I N G S . A . D I F F U S E R A N D B R A N C H REMOVE EXISTING S.A. DIFFUSER AND BRANCH REMOVE EXISTING S.A. DIFFUSER AND BRANCH REMOVE EXISTING S.A. DIFFUSER AND BRANCH DUCTWORK AS SHOWN.DUCTWORK AS SHOWN.DUCTWORK AS SHOWN.DUCTWORK AS SHOWN.6 66 6 C A P S . A . D U C T W O R K . CAP S.A. DUCTWORK.CAP S.A. DUCTWORK.CAP S.A. DUCTWORK.7 77 7 R E M O V E E X I S T I N G R O O M T E M P E R A T U R E S E N S O R . REMOVE EXISTING ROOM TEMPERATURE SENSOR.REMOVE EXISTING ROOM TEMPERATURE SENSOR.REMOVE EXISTING ROOM TEMPERATURE SENSOR.8 88 8 R E M O V E E X I S T I N G R O O M T E M P E R A T U R E S E N S O R REMOVE EXISTING ROOM TEMPERATURE SENSOR REMOVE EXISTING ROOM TEMPERATURE SENSOR REMOVE EXISTING ROOM TEMPERATURE SENSOR AND WIRING.AND WIRING.AND WIRING.AND WIRING.9 99 9 R E M O V E E X I S T I N G S U P P L Y A I R D I F F U S E R I N REMOVE EXISTING SUPPLY AIR DIFFUSER IN REMOVE EXISTING SUPPLY AIR DIFFUSER IN REMOVE EXISTING SUPPLY AIR DIFFUSER IN PREPARATION FOR NEW DIFFUSER IN NEW CEILING.PREPARATION FOR NEW DIFFUSER IN NEW CEILING.PREPARATION FOR NEW DIFFUSER IN NEW CEILING.PREPARATION FOR NEW DIFFUSER IN NEW CEILING. 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 B BB B C CC C D DD D E EE E 9 EX I S T I N G S T O R A G E 4 ST O R A G E 3 WE L C O M E R O O M 5 SE A T I N G A 6 SE A T I N G B 7 WE L C O M E / H E L P D E S K 12 CO R R I D O R B 1 11 1 2 22 2 3 33 3 1 11 1 5 55 5 6 66 6 7 77 7 8 88 8 8 88 8 8 88 8 S 1 11 1 S 7 77 7 S 7 77 7 S 6 66 6 S 1 11 1 1 11 1 2 22 2 6 66 6 S 5 55 5 1 11 1 1 11 1 1 11 1 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 1 11 1 1 11 1 1 11 1 1 11 1 4 44 4 4 44 4 4 44 4 4 44 4 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 12 " x 8 " + 1 " A L 12 " x 8 " + 1 " A L 12 " x 8 " + 1 " A L 12 " x 8 " + 1 " A L 1 11 1 1 11 1 H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 26 6 D 26 6 D 26 6 D 26 6 D DV A V DV A V DV A V DV A V 8" Ø 8" Ø 8 " Ø 8" Ø 6" Ø 6" Ø 6 " Ø 6" Ø 5 55 5 5 55 5 5 55 5 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 10 1010 10 10 1010 10 10 1010 10 dbkbo^i=klqbp A.A.A.A.REPLACE EXISTING FLEX DUCT WHERE DIFFUSERS REPLACE EXISTING FLEX DUCT WHERE DIFFUSERS REPLACE EXISTING FLEX DUCT WHERE DIFFUSERS REPLACE EXISTING FLEX DUCT WHERE DIFFUSERS ARE BEING REPLACED AND DUCT RUNOUTS REMAIN.ARE BEING REPLACED AND DUCT RUNOUTS REMAIN.ARE BEING REPLACED AND DUCT RUNOUTS REMAIN.ARE BEING REPLACED AND DUCT RUNOUTS REMAIN.3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 SECOND LEVEL MECHANICAL REMODEL PLAN12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Set 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 ao^tfkd=klqbp SC A L E : SC A L E : SC A L E : SC A L E : MH 1 0 1 MH 1 0 1 MH 1 0 1 MH 1 0 1 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" pb ` l k a = i b s b i = j b ` e ^ k f ` ^ i = o b j l a b i mi ^ k 1 11 1 NOTE #DIFFUSER CALLOUT DESCRIPTION 1 11 1 S-1 S-1S-1 S-1 150 CFM, 8"Ø NK S.A. DIFFUSER 150 CFM, 8"Ø NK S.A. DIFFUSER 150 CFM, 8"Ø NK S.A. DIFFUSER 150 CFM, 8"Ø NK S.A. DIFFUSER 2 22 2 S-1 S-1S-1 S-1 130 CFM, 8"Ø NK S.A. DIFFUSER 130 CFM, 8"Ø NK S.A. DIFFUSER 130 CFM, 8"Ø NK S.A. DIFFUSER 130 CFM, 8"Ø NK S.A. DIFFUSER 3 33 3 S - 2 S-2S-2 S-2 190 CFM, 8"Ø NK S.A. DIFFUSER 190 CFM, 8"Ø NK S.A. DIFFUSER 190 CFM, 8"Ø NK S.A. DIFFUSER 190 CFM, 8"Ø NK S.A. DIFFUSER 4 44 4 S - 2 S-2S-2 S-2 200 CFM, 8"Ø NK S.A. DIFFUSER 200 CFM, 8"Ø NK S.A. DIFFUSER 200 CFM, 8"Ø NK S.A. DIFFUSER 200 CFM, 8"Ø NK S.A. DIFFUSER 5 55 5 R - 1 R-1R-1 R-1 2 2 " x 2 2 " N K R E T U R N A I R G R I L L E W I T H 22"x22" NK RETURN AIR GRILLE WITH 22"x22" NK RETURN AIR GRILLE WITH 22"x22" NK RETURN AIR GRILLE WITH SOUND BOOT SOUND BOOT SOUND BOOT SOUND BOOT 6 66 6 P R O V I D E N E W R O O M T E M P E R A T U R E PROVIDE NEW ROOM TEMPERATURE PROVIDE NEW ROOM TEMPERATURE PROVIDE NEW ROOM TEMPERATURE SENSOR IN NEW LOCATION AS SHOWN.SENSOR IN NEW LOCATION AS SHOWN.SENSOR IN NEW LOCATION AS SHOWN.SENSOR IN NEW LOCATION AS SHOWN.7 77 7 P R O V I D E N E W R O O M T E M P E R A T U R E PROVIDE NEW ROOM TEMPERATURE PROVIDE NEW ROOM TEMPERATURE PROVIDE NEW ROOM TEMPERATURE SENSOR IN EXISTING LOCATION.SENSOR IN EXISTING LOCATION.SENSOR IN EXISTING LOCATION.SENSOR IN EXISTING LOCATION.8 88 8 S - 1 S-1S-1 S-1 1 9 0 C F M , 8 " Ø N K S . A . D I F F U S E R 190 CFM, 8"Ø NK S.A. DIFFUSER 190 CFM, 8"Ø NK S.A. DIFFUSER 190 CFM, 8"Ø NK S.A. DIFFUSER 9 99 9 S - 1 S-1S-1 S-1 4 0 0 C F M , 8 " Ø N K S . A . D I F F U S E R 400 CFM, 8"Ø NK S.A. DIFFUSER 400 CFM, 8"Ø NK S.A. DIFFUSER 400 CFM, 8"Ø NK S.A. DIFFUSER 10 1010 10 1 2 " x 1 2 " + 1 " A L R E T U R N A I R O P E N I N G I N 12"x12"+1"AL RETURN AIR OPENING IN 12"x12"+1"AL RETURN AIR OPENING IN 12"x12"+1"AL RETURN AIR OPENING IN WALL WITH SOUND BOOT WALL WITH SOUND BOOT WALL WITH SOUND BOOT WALL WITH SOUND BOOT BA R S L I P H TR A N S V E R S E R E I N F O R C I N G S I Z E I S D E T E R M I N E D B Y D I M E N S IO N O F S I D E T O W H I C H A N G L E I S A P P L I E D . * 43 - 5 4 55 - 6 0 61 - 8 4 22 20 20 1- 1 / 2 x 1 - 1 / 2 x 1 / 8 @ 6 0 i n . 1 - 1 / 2 1- 1 / 2 1- 1 / 2 --- --- -22 - 31 - 4 2 19 - 3 0 13 - 1 8 24 2224 UP T H R U 1 2 24 (A L L SID E , (I N C H E S ) SID E S ) FO U R OF DIM E N S I O N LO N G E S T SH E E T ME T A L GA G E ME N D E D RE C O M - NO N E R E Q U I R E D 1 x 1 x 1 / 8 @ 6 0 i n . 1 x 1 x 1 / 8 @ 6 0 i n . 111 NO N E R E Q U I R E D 1 2424 - --24 222424 RE C O M - ME N D E D 26 GA G E GA G E 26 ME N D E D RE C O M - 24 GA G E SP A C I N G BE T W E E N RE I N F O R C I N G IN T E R M E D I A T E JO I N T S & / O R TR A N S V E R S E MIN H, I N . & M A X I M U M AN G L E S I Z E RE I N F O R C I N G LO N G I T U D I N A L MIN I M U M HE M M E D S S L I P S S L I P PL A I N A L T . SL I P DR I V E 22 22 222222 22NOT REQUIRED NOT REQUIRED22 22 22POCKET LOCK MENDEDRECOM-POCKET LOCKANGLE REINFORCED GAGEANGLE NOT REQUIREDSIZEREINFORCED 222424 222424RECOM-MENDED GAGEMENDEDRECOM-24GAGE 24 NOT REQUIREDNOT REQUIREDNOT REQUIRED 222424REINFORCEDANGLENOT REQUIREDSIZE 24REIN-FORCED BAR SLIP ANGLE SLIPHHBAR SLIP ANGLE STD. SEAMREINFORCEDSTD. SEAM REINFORCED ANGLE SIZEHAT JOINTSTRANSVERSE REINFORCING * H H 1-1/2 x 1-1/2 x 1/8 1-1/2 x 1-1/2 x 1/8 1-1/2 x 1-1/2 x 1/8NOT REQUIRED NOT REQUIRED NOT REQUIRED 1-1/2 x 1-1/2 x 1/8NOT REQUIRED NOT REQUIREDNOT REQUIREDNOT REQUIREDNOT REQUIREDNOT REQUIRED 1-1/2 x 1-1/2 x 1/8 1- 1 / 2 x 1 - 1 / 2 x 1 / 8 @ 6 0 i n . 1- 1 / 2 x 1 - 1 / 2 x 1 / 8 @ 6 0 i n . 45 DEG. ELBOWTURNINGVANESSINGLEBLADE ELBOWS NOT ALLOWED.ALL DUCTS (SUPPLY, RETURN VANES IN SQUARE ELBOW.INSIDE SQUARE, OUTSIDE RADIUSAND EXHAUST) TO HAVE TURNINGSQUARE ELBOW 2.1.NOTES:RADIUS ELBOWWBOTH SIDES TURNING VANES15° MAX.ONE SIDE 1/2 W30° MAX.C L45° LATERAL TEECONICAL 90° TEE Y-BRANCH 90°BRANCH TAKE-OFF DIMENSIONS FABRICATED ELBOWDRADD ONE PIECE FOR EACH ADDITIONAL 18°R = 1.5DD = DUCT SIZE 0-35° ---- 2 PIECE 72-90° ----5 PIECE36-71° ----3 PIECE L DMITERED 90° ELBOW REDUCER OFFSET1A MAX.2"1-1/4"A2ATURNINGVANES A1-1/4"D45°D = DUCT SIZEDIMENSIONS L = D/2+1"D2"DUCT SIDE. PROVIDE 1" TRAILINGTO START AND STOP PARALLEL WITHANGLE OF DIRECTION CHANGE. VANESEXHAUST) TO HAVE TURNING VANESALL DUCTS (SUPPLY, RETURN AND WITH SQUARE TYPE ELBOWS AT ANY EDGE.NOTE: 1" kl = m l m = o f s b q p = ^ i i l t b a TO B E T I G H T A G A I N S T D U C T . HE A D S H E E T M E T A L S C R E W S . S T R A P S SE L F T A P P I N G C A D M I U M P L A T E D H E X HA N G E R S T R A P S e^ k d b o = p f w b p = c l o = o b ` q ^ k d r i ^ o ar ` q = m b o = p j ^ ` k ^ = e s ^ ` = a r ` q `l k p q o r ` q f l k = p q ^ k a ^ o a p kl = m l m = o f s b q p = ^ i i l t b a HA N G E R ST R A P S `l k p q o r ` q f l k = p q ^ k a ^ o a p ar ` q = m b o = p j ^ ` k ^ = e s ^ ` = a r ` q e^ k d b o = p f w b p = c l o = o l r k a SE L F T A P P I N G H E X H E A D S H E E T ME T A L S C R E W S . S T R A P S T O B E TI G H T A G A I N S T D U C T AN G L E I R O N RO U N D / O V A L D U C T AN G L E I R O N HA N G E R S T R A P S e^ k d b o = p f w b p = c l o = o l r k a = L = l s ^ i ar ` q = m b o = p j ^ ` k ^ = e s ^ ` = a r ` q `l k p q o r ` q f l k = p q ^ k a ^ o a p (M I R A C L E P F 9 6 ) 1 2 " C . C . M A X . ME T A L F A S T E N E R S : OR G R I P N A I L S . G R I P N A I L S S H A L L B E IN S T A L L E D B Y " G R I P N A I L A I R H A M M E R " O R BY " A U T O M A T I C F A S T E N E R E Q U I P M E N T " . OM A R K I N S U L - P I N S , D U R A D Y N E F A S T E N E R S NO T M O R E T H A N 2 " FR O M E D G E O F L I N E R 2 " ( TY P . ) TH E S I D E S OF L I N E R S H A L L O V E R L A P TO P A N D B O T T O M S E C T I O N WIT H 1 0 0 % A D H E S I V E BE A D H E R E D T O D U C T DU C T L I N E R . L I N E R T O GA L V A N I Z E D I R O N D U C T DU C T L I N E R AL L E N D S O F L I N E R T O B E C O A T E D W I T H AD H E S I V E ( M I R A C L E P F 9 6 ) . E N D S O F L I N E R SH A L L B E B U T T E D F I R M L Y T O G E T H E R HO T D U C T TR A N S I T I O N F R O M D I S C H A R G E E N D AS R E Q U I R E D T O S I Z E I N D I C A T E D ON P L A N S . SE E P L A N S F O R S I Z I N G . AC O U S T I C A L L Y L I N E D D U C T , CO N T R O L S ( T Y P I C A L ) RE Q U I R E D OF V A V B O X A S TR A N S I T I O N T O I N L E T SIZ I N G A N D L O C A T I O N . VA V B O X , S E E P L A N S F O R CO N I C A L T E E F I T T I N G ( T Y P I C A L ) CO L D D U C T 12 " L O N G M I N . FU L L S I Z E T R A N S I T I O N P L E N U M H. D . SE E P L A N S F O R S I Z I N G . BR A N C H D U C T T O D I F F U S E R S , 5'- 0 " M I N . SH E E T M E T A L D U C T DU C T S E C T I O N LO C K I N G Q U A D R A N T ST R A P 1 / 2 " R O D 45 ° D U C T C O N N E C T I O N BL A D E W I T H V - G R O O V E BL A D E S E C T I O N 1/2 " R O D BR A N C H D U C T O R R U N O U T TO D I F F U S E R , S E E P L A N S FO R S I Z I N G RE C T A N G U L A R D U C T , S E E PL A N S F O R S I Z I N G LO C K I N G Q U A D R A N T (O N E P E R B L A D E ) ST R A P , R I V E T T O B L A D E (T A C K W E L D R O D SE C U R E L Y T O B L A D E ) 22 G A . B L A D E 1 / 2 " SP R I N G L O A D E D E N D TA C K W E L D O R R I V E T TO B L A D E ( B L A D E M U S T CL E A R L I N E R O R D U C T AP P R O X . 1 / 4 " O N A L L S I D E S ) BL A D E M U L T I P L E S DU C T D E P T H UP T O 1 2 " - 1 B L A D E UP T O 2 0 " - 2 B L A D E S UP T O 3 0 " - 3 B L A D E S FO R S I Z I N G RO U N D D U C T , S E E P L A N S MA D E D U C T . M A X . L E N G T H 6 ' - 0 " . FA S T E N W I T H M A S T I C A N D B I N D I N G HIG H P R E S S U R E R A T E D F A C T O R Y SU P P L Y D I F F U S E R , S E E PL A N S F O R S I Z I N G CE I L I N G ST R A P . S E E D E T A I L T H I S S H E E T . BIN D I N G S T R A P BIN D I N G S T R A P 5/8 " S C R E W T I G H T E N I N G FA C T O R Y M A D E D U C T W I T H WO V E N F I B E R G L A S S F A B R I C MA S T I C ME T A L D U C T RO U N D S H E E T 2" ME T A L S C R E W ( T Y P . 3 ) T H R O U G H FA C T O R Y D U C T I N T O R O U N D FA C T O R Y D U C T I N P L A C E SH E E T M E T A L D U C T T O H O L D HIG H P R E S S U R E R A T E D S H E E T IM P R E G N A T E D W I T H V I N Y L O R NE O P R E N E C L A M P E D I N A C O N T I N U A L HE L I X O F A L U M I N U M O R C O L D RO L L E D S T E E L , 3 ' - 0 " M A X . L E N G T H FL E X M A S T E R T Y P E 4 O R TH E R M A F L E X M - K C NO T E : EQ U A L C R O S S S E C T I O N A R E A O F AR E A O F A x C S H A L L B E E Q U A L MIN I M U M A R E A O F A x B S H A L L TO 1 . 5 x A R E A O F A x B . BR A N C H D U C T . C HA N D D A M P E R W I T H LO C K I N G Q U A D R A N T A PL A N S F O R S I Z I N G RE C T A N G U L A R D U C T , S E E RO U N D D U C T R U N O U T TO D I F F U S E R , S E E PL A N S F O R S I Z I N G B 45 ° RE T U R N SH E E T M E T A L S C R E W S 1" W I D E 22 G A . S H E E T UN D E R 2 " A N D FA S T E N W I T H SH E E T M E T A L TU R N H A N G E R ME T A L S K I N AC O U S T I C A L 1" I N T E R I O R DE N S I T Y LI N I N G , 1 P C F SC R E W . W ( 1 2" M I N . ) W 1/2 W ( M I N . 8 " + A L ) GR I L L E LE N G T H 1/2 W HA N G I N G ST R A P AIR G R I L L E AC O U S T I C A L NO L I N E O F S I G H T T H R O U G H CO N S T R U C T E D S O T H E R E I S SO U N D B O O T T O B E TH E S O U N D B O O T . NO T E : 1" I N T E R I O R LI N I N G , 1 l b . DE N S I T Y W W +2 " W L WA L L W W W+ 2 " LI N E O F S I G H T 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 MECHANICAL DETAILS12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Set SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH501 MH501 MH501 MH501 ar ` q = ` l k p q o r ` q f l k = a b q ^ f i 1 11 1 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MH501 MH501 MH501 MH501ob`q^kdri^o=ar`q=cfqqfkdp=abq^fi 2 22 2 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MH501 MH501 MH501 MH501jbafrj=sbil`fqv=ar`q=cfqqfkdp abq^fi 3 33 3 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ar ` q = p q o ^ m = e ^ k d b o = a b q ^ f i 4 44 4 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ol r k a = a r ` q = e ^ k d b o = a b q ^ f i 5 55 5 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ls ^ i = a r ` q = e ^ k d b o = a b q ^ f i 6 66 6 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ar ` q = i f k b o = a b q ^ f i 7 77 7 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ar ^ i = a r ` q = s ^ s = a b q ^ f i 8 88 8 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 _o ^ k ` e = a r ` q = ^ k a = a ^ j m b o = a b q ^ f i 9 99 9 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ar ` q = ` l k k b ` q f l k = q l = a f c c r p b o ab q ^ f i 10 1010 10 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 c^ ` q l o v = j ^ a b = a r ` q = a b q ^ f i 11 1111 11 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ar ` q = ` l k k b ` q f l k = a b q ^ f i 12 1212 12 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 pl r k a = _ l l q = a b q ^ f i 13 1313 13 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 qo ^ k p c b o L o b q r o k = ^ f o = p l r k a = _ l l q ab q ^ f i 14 1414 14 GENERAL NOTES FOR MECHANICAL CONTROLS PR E S S U R E S W I T C H E S , E L E C T R I C O P E R A T E D V A L V E S , E T C . A RE THE RESPONSIBILITY OF DIVISION 23. AT C P A N E L S , S E N S O R S , E T C , A S I N D I C A T E D O N T H E P L A N S ALL IN ACCORDANCE WITH DIVISION 26. AN Y Q U E S T I O N O F R E S P O N S I B I L I T Y S H A L L B E C L A R I F I E D B Y THE GENERAL CONTRACTOR TH E C O N T R O L S C O N T R A C T O R S H A L L P R O V I D E S H O P D R A W I N G S FOR CONTROL SYSTEMS CIRCUITS. TH E C O N T R O L S C O N T R A C T O R S H A L L R O U T E A L L C O N D U I T F O R MECHANICAL CONTROLS, PULL WIRING REQUIRED FO R M E C H A N I C A L C O N T R O L S T H R O U G H T H E C O N D U I T S A N D M A KE CONNECTIONS TO MECHANICAL EQUIPMENT, TH R O U G H T H E C O N T R O L D E V I C E A N D B A C K T O T H E J U N C T I O N BOX. CO N T R O L S C O N T R A C T O R S H A L L I N T E R R U P T T H E C I R C U I T I N THE MECHANICAL EQUIPMENT JUNCTION BOX, WIRE TH E E L E C T R I C I A N S H A L L R U N A N D C O N N E C T A L L W I R I N G A N D DEVICES 120 VOLTS AND ABOVE WHICH POWER AU X I L I A R Y R E L A Y S , L O W V O L T A G E T R A N S F O R M E R S , C O N T R O L PANEL SWITCHES AND DEVICES, THERMOSTATS, AL L W I R I N G S H A L L T E R M I N A T E A T L A B E L E D T E R M I N A L S T R I PS. 10 .9.8. CO N T R O L S C O N T R A C T O R ( D I V 2 3 ) . PR O D U C T S A N D P R A C T I C E S S H A L L B E S I M I L A R F O R A L L I N STALLATIONS. RE S P O N S I B I L I T Y O F D I V I S I O N 2 6 . BR E A K E R S A N D D I S C O N N E C T S , A U X I L I A R Y C O N T A C T S , S T A N D ARD PILOT LIGHTS AND MAGNETIC STARTERS ARE THE GE N E R A L C O N T R A C T . O F S P E C I F I C C O N C E R N A R E T H E C O N T ROL SYSTEMS RELATED TO MECHANICAL EQUIPMENT. RE S P O N S I B I L I T Y F O R T H E C O N T R O L W O R K I S D I V I D E D B E T W EEN THE PROJECT ELECTRICIAN (DIV. 26) AND A SPECIAL TY AL L E L E C T R I C A L I N S T A L L A T I O N , B E I T P O W E R D I S T R I B U T I ON OR SPECIAL SYSTEMS, IS INCLUDED IN THE SCOPE OF THE TH E E L E C T R I C I A N S H A L L P R O V I D E A L L P O W E R T O A N D T H R O UGHOUT THE BUILDING, TO INCLUDE MOTOR CONTROL AL L E L E C T R I C A L W O R K S H A L L B E I N A C C O R D A N C E W I T H D I V ISION 26 AND TO THE FULLEST EXTENT POSSIBLE, CE N T E R S , B R E A K E R P A N E L S A N D A L L O T H E R S Y S T E M S D E S I G NATED TO THE ELECTRICIANS. MO T O R S A N D O T H E R M E C H A N I C A L D E V I C E S . W H E R E C O N T R O L DEVICES ARE LOCATED IN POWER CIRCUIT, THE 7.6.5.4.3.2.1. 120/60/1 POWER TR U N K CO M M U N I C A T I O N DDC CONTROLLER CT H RFIRE ALARM CONTACTTRANSFORMER,QUANTITY AS REQUIRED BY DIV. 26N S S S DD C C O N T R O L L E R SE N S O R VE L O C I T Y TE M P / IN L V T P TR A N S F O R M E R S WIR I N G T O VE L O C I T Y SE N S O R TE M P / VS DAMPER MOTORMAIN COMMUNICATION TRUNK DAMPER MOTORCT DUAL COMMUNICATION FOR LOCATIONDUAL THERMISTOR WALL SENSOR, SEE DRAWINGSWALL SENSOR (TYPICAL)DOR SMART II DVS HO T D U C T CO L D D U C T AI AI A I A O AO FLOORUP WITH LIGHT SWITCHSENSOR SHALL LINECONCRETE BLOCK OR STUD WALL STUD SPACE FIELD COORDINATE WITHCONCRETE WALL OR CONCEALED WITHINCONTROL CONDUIT EMBEDDED WITHIN ELBOWRADIUS ELBOWNOMINAL 2"x4"x2-1/2" DEEP ROOM SENSOR OR SWITCH 48"„J-BOX NOTE:WALL CONSTRUCTION 90° SHORT 2 P O S I T I O N O R DA M P E R M O T O R DM CO N T R O L S I G N A L FR O M D D C P A N E L MO D U L A T I N G A S S H O W N (E ) E T H E R N E T CO N N E C T I O N (T Y P I C A L ) 24 V P O W E R FR O M L O C A L L V T P BY D I V . 2 3 , T Y P . 24 V P O W E R FR O M L O C A L L V T P BY D I V . 2 3 , T Y P . LO N B U S , T Y P . LV T P 12 0 V P O W E R BY D I V . 2 6 QU A N T I T Y A S IN D I C A T E D O N P L A N S LV T P 12 0 V P O W E R BY D I V . 2 6 QU A N T I T Y A S IN D I C A T E D O N P L A N S 12 0 V P O W E R BY D I V . 2 6 24 V P O W E R FR O M L O C A L L V T P BY D I V . 2 3 , T Y P . EX I S T I N G N A E P A N E L MA K E M O D I F I C A T I O N S T O E X I S T I N G P A N E L AS N E E D E D I N O R D E R T O A C C O M M O D A T E TH E C O N T R O L A N D M O N I T O R I N G O F N E W TE R M I N A L U N I T S . 24 V P O W E R T O T E R M I N A L UN I T D D C C O N T R O L L E R S QU A N T I T Y A S R E Q ' D B Y D I V . 2 3 24 V P O W E R T O T E R M I N A L UN I T D D C C O N T R O L L E R S QU A N T I T Y A S R E Q ' D B Y D I V . 2 3 DV A V C O N T R O L L E R S (Q U A N T I T Y A S R E Q ' D . S E E D R A W I N G S T Y P . ) 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 MECHANICAL CONTROL DIAGRAMS12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Set SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MI601 MI601 MI601 MI601 il t = s l i q ^ d b = q o ^ k p c l o j b o = m ^ k b i Ei s q m F 1 11 1 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MI601 MI601 MI601 MI601 ar ^ i = a r ` q = e b ^ q f k d = ^ k a = ` l l i f k d `l k q o l i = a f ^ d o ^ j 2 22 2 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MI601 MI601 MI601 MI601 pb k p l o = j l r k q f k d = a f ^ d o ^ j 3 33 3 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MI6 0 1 MI6 0 1 MI6 0 1 MI6 0 1 qv m f ` ^ i = a ^ j m b o = j l q l o = a f ^ d o ^ j 4 44 4 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MI6 0 1 MI6 0 1 MI6 0 1 MI6 0 1 ob s f p b a = l k b J if k b = a f ^ d o ^ j 5 55 5 dbkbo^i=klqbp A.B.THIS DRAWING IS FOR REFERENCE ONLY FOR THE PURPOSES OF THE CONTRACTOR'S BIDDING OF THE DESIGN, (INCLUDING PREPARATION OF DETAILED FIRE SPRINKLER PLANS AND DOCUMENTS), AND THE FURNISHING, INSTALLING AND MAKING OPERATIONAL, A COMPLETE AUTOMATIC FIRE SPRINKLER SYSTEM FOR ALL REMODEL AREAS OF THE BUILDING. REFERENCE SPECIFICATION 211313 FOR ADDITIONAL INFORMATION AND REQUIREMENTS.THE AUTOMATIC FIRE SPRINKLER DESIGN, PLANS AND DOCUMENTS AS PREPARED BY THE CONTRACTOR, ARE TO BE SUBMITTED BY THE CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION UNDER A SEPARATE PLAN SUBMITTAL AND PERMIT FOR THE AUTHORITY HAVING JURISDICTION'S REVIEW, APPROVAL AND PERMITTING.cfob=pmofkhibo=ibdbka SYMBOL D E S C R I P T I O N NEW FIRE SPRINKLER HEAD - CONCEALED TYPE SPRINKLER HEAD EXISTING FIRE SPRINKLER HEAD 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 B BB B C CC C D DD D E EE E 1 11 1 2 22 2 2 22 2 4 44 4 1 11 1 3 33 3 2 22 2 1 11 1 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 3 33 3 3 33 3 3 33 3 4 44 4 4 44 44444 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 22222 2 22 22222 2 22 2 2 22 2 2 22 2 2 22 2 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 SECOND LEVEL FIRE PROTECTION DEMOLITION PLAN12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Setao^tfkd=klqbp NOTE #DESCRIPTION 1 11 1 REMOVE EXISTING FIRE SPRINKLER PIPING IN REMOVE EXISTING FIRE SPRINKLER PIPING IN REMOVE EXISTING FIRE SPRINKLER PIPING IN REMOVE EXISTING FIRE SPRINKLER PIPING IN REMODEL SPACE AS REQUIRED TO REMODEL SPACE AS REQUIRED TO REMODEL SPACE AS REQUIRED TO REMODEL SPACE AS REQUIRED TO ACCOMMODATE THE REMODEL WORK OF ALL ACCOMMODATE THE REMODEL WORK OF ALL ACCOMMODATE THE REMODEL WORK OF ALL ACCOMMODATE THE REMODEL WORK OF ALL TRADES. MAINTAIN EXISTING WHERE FEASIBLE.TRADES. MAINTAIN EXISTING WHERE FEASIBLE.TRADES. MAINTAIN EXISTING WHERE FEASIBLE.TRADES. MAINTAIN EXISTING WHERE FEASIBLE.2 22 2 R E M O V E E X I S T I N G F I R E S P R I N K L E R H E A D A N D REMOVE EXISTING FIRE SPRINKLER HEAD AND REMOVE EXISTING FIRE SPRINKLER HEAD AND REMOVE EXISTING FIRE SPRINKLER HEAD AND ASSOCIATED BRANCH PIPING AS REQUIRED ASSOCIATED BRANCH PIPING AS REQUIRED ASSOCIATED BRANCH PIPING AS REQUIRED ASSOCIATED BRANCH PIPING AS REQUIRED PREPARATORY FOR NEW IN NEW LOCATION.PREPARATORY FOR NEW IN NEW LOCATION.PREPARATORY FOR NEW IN NEW LOCATION.PREPARATORY FOR NEW IN NEW LOCATION.3 33 3 N O F I R E S P R I N K L E R W O R K I N T H I S A R E A . NO FIRE SPRINKLER WORK IN THIS AREA.NO FIRE SPRINKLER WORK IN THIS AREA.NO FIRE SPRINKLER WORK IN THIS AREA.PROTECT DURING CONSTRUCTION.PROTECT DURING CONSTRUCTION.PROTECT DURING CONSTRUCTION.PROTECT DURING CONSTRUCTION.4 44 4 R E M O V E E X I S T I N G S P R I N K L E R H E A D A N D REMOVE EXISTING SPRINKLER HEAD AND REMOVE EXISTING SPRINKLER HEAD AND REMOVE EXISTING SPRINKLER HEAD AND ASSOCIATED BRANCH PIPE TO TEE AT MAIN. CAP ASSOCIATED BRANCH PIPE TO TEE AT MAIN. CAP ASSOCIATED BRANCH PIPE TO TEE AT MAIN. CAP ASSOCIATED BRANCH PIPE TO TEE AT MAIN. CAP TEE.TEE.TEE.TEE. SC A L E : SC A L E : SC A L E : SC A L E : FD 1 0 1 FD 1 0 1 FD 1 0 1 FD 1 0 1 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" pb ` l k a = i b s b i = j b ` e ^ k f ` ^ i ab j l i f q f l k = m i ^ k 1 11 1 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 dbkbo^i=klqbp A.B.THIS DRAWING IS FOR REFERENCE ONLY FOR THE PURPOSES OF THE CONTRACTOR'S BIDDING OF THE DESIGN, (INCLUDING PREPARATION OF DETAILED FIRE SPRINKLER PLANS AND DOCUMENTS), AND THE FURNISHING, INSTALLING AND MAKING OPERATIONAL, A COMPLETE AUTOMATIC FIRE SPRINKLER SYSTEM FOR ALL REMODEL AREAS OF THE BUILDING. REFERENCE SPECIFICATION 211313 FOR ADDITIONAL INFORMATION AND REQUIREMENTS.THE AUTOMATIC FIRE SPRINKLER DESIGN, PLANS AND DOCUMENTS AS PREPARED BY THE CONTRACTOR, ARE TO BE SUBMITTED BY THE CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION UNDER A SEPARATE PLAN SUBMITTAL AND PERMIT FOR THE AUTHORITY HAVING JURISDICTION'S REVIEW, APPROVAL AND PERMITTING.cfob=pmofkhibo=ibdbka SYMBOL D E S C R I P T I O N NEW FIRE SPRINKLER HEAD - CONCEALED TYPE SPRINKLER HEAD EXISTING FIRE SPRINKLER HEADcfob=molqb`qflk=klqbp 9.6.5.4.3.2.1.8.7.ALL HANGERS, SUPPORTS, AND SEISMIC BRACING AS PER SPECIFICATIONS AND DRAWINGS. UNLESS NOTED OTHERWIS E,INSTALLATION MUST AT LEAST MEET NFPA 13 STANDARD.SIZE OF PIPE TO ONE SPRINKLER HEAD TO BE 1" UNLESS NOTED OTHERWISE.PROVIDE SWAY BRACING IN ACCORDANCE WITH NFPA 13 ON ALL SYSTEM MAINS.SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF OF SPRINKLER HEADS WHERE NOTED.SEAL ALL PENETRATIONS THRU FIRE WALLS AND FLOOR WIT H FIRE PROOF SEALANT AS PER SPECIFICATIONS.COORDINATE FINISH OF SPRINKLER HEAD COVERS WITH ARCHITECT.REQUIRED FINISH MAY VARY FROM MANUFACTURERS STANDARD FINISHES.SPACE OCCUPANCY IS LIGHT HAZARD (EXCEPT AS NOTED IN SPECIFICATION) WITH COVERAGE LIMITED TO LESS THAN 2 25 SQ. FT. PER HEAD.DUE TO THE CLOSE PROXIMITY OF THE WATER, VENT, HOT WATER HEATING, AND FIRE SPRINKLER PIPING, AS WELL A S DUCTWORK, COORDINATE THE MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, AND SHEETMETAL WORK.ROUTE MAIN FIRE PROTECTION PIPING TO ENSURE ROUTING DOES NOT CONFLICT WITH OTHER TRADES.PROVIDE ADDITIONAL SPRINKLER HEADS ABOVE AND/OR BELOW DUCTWORK, STRUCTURES, ETC. AS REQUIRED FOR COMPLETE BUILDING COVERAGE.ALL MATERIALS AND EQUIPMENT USED FOR THE FIRE SPRINKLER SYSTEM SHALL BE U.L. LISTED OR FM APPROVE D FOR USE IN FIRE PROTECTION SYSTEMS.10.11.12.13.FURNISH ALL MATERIALS, EQUIPMENT AND SUPPLIES AND PERFORM ALL WORK AND OPERATIONS REQUIRED TO DESIGN,CONSTRUCT, AND MAKE FUNCTIONAL A FIRE SPRINKLER SYSTEM TO PROVIDE FIRE PROTECTION OF ALL REMODEL AREAS OF THE BUILDING. THE SYSTEM SHALL MEET THE REQUIREMENTS OF THE UTAH FIRE CODE AND SPECIFICATIO N SECTION 211313.14.PIPING SHALL BE STEEL PIPING CONFORMING TO ANSI/AST M A53, ASTM A135 OR ASTM A795. PIPING 2-1/2" (NOMINA L)OR LARGER SHALL BE SCHEDULE 10. PIPING 2" (NOMINAL ) OR SMALLER SHALL BE SCHEDULE 40. N O XL OR THIN WALL PIPE WILL BE ALLOWED.PROVIDE NEW FIRE SPRINKLER PIPING IN REMODEL SPACE AS REQUIRED TO ACCOMMODATE THE REMODEL WORK OF ALL TRADES. MAINTAIN EXISTING WHERE FEASIBLE. NOTE: CEI LING HEIGHTS ARE BEING CHANGED IN MANY LOCATIONS AND WIL L LIKELY IMPACT THE LOCATION OF EXISTING PIPING. 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 B BB B C CC C D DD D E EE E 1 11 1 2 22 2 4 44 4 3 33 3 3 33 3 3 33 3 3 33 3 4 44 4 4 44 4 1 11 11111 1 11 11111 1 11 1 1 11 1 1 11 1 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 1 11 1 1 11 1 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 2 22 2 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 SECOND LEVEL FIRE PROTECTION REMODEL PLAN12249March 25, 2022BYUIMANWARINGWELCOMECENTERREMODEL Bid Setao^tfkd=klqbp NOTE #DESCRIPTION 1 11 1 INSTALL NEW FIRE SPRINKLERS WHERE REQUIRED INSTALL NEW FIRE SPRINKLERS WHERE REQUIRED INSTALL NEW FIRE SPRINKLERS WHERE REQUIRED INSTALL NEW FIRE SPRINKLERS WHERE REQUIRED FOR NEW ROOM LAYOUT. NEW SPRINKLERS FOR NEW ROOM LAYOUT. NEW SPRINKLERS FOR NEW ROOM LAYOUT. NEW SPRINKLERS FOR NEW ROOM LAYOUT. NEW SPRINKLERS SHALL BE CONCEALED TYPE, PENDANT SHALL BE CONCEALED TYPE, PENDANT SHALL BE CONCEALED TYPE, PENDANT SHALL BE CONCEALED TYPE, PENDANT SPRINKLERS WITH WHITE COVER PLATE. CONNECT SPRINKLERS WITH WHITE COVER PLATE. CONNECT SPRINKLERS WITH WHITE COVER PLATE. CONNECT SPRINKLERS WITH WHITE COVER PLATE. CONNECT NEW SPRINKLERS TO EXISTING BRANCH TEE WITH NEW SPRINKLERS TO EXISTING BRANCH TEE WITH NEW SPRINKLERS TO EXISTING BRANCH TEE WITH NEW SPRINKLERS TO EXISTING BRANCH TEE WITH NEW BRANCH PIPING TO LOCATE NEW HEADS IN NEW BRANCH PIPING TO LOCATE NEW HEADS IN NEW BRANCH PIPING TO LOCATE NEW HEADS IN NEW BRANCH PIPING TO LOCATE NEW HEADS IN NEW CEILING.NEW CEILING.NEW CEILING.NEW CEILING.2 22 2 P R O V I D E N E W S P R I N K L E R P I P I N G , C O N C E A L E D PROVIDE NEW SPRINKLER PIPING, CONCEALED PROVIDE NEW SPRINKLER PIPING, CONCEALED PROVIDE NEW SPRINKLER PIPING, CONCEALED TYPE FIRE SPRINKLER HEADS AND REQUIRED TYPE FIRE SPRINKLER HEADS AND REQUIRED TYPE FIRE SPRINKLER HEADS AND REQUIRED TYPE FIRE SPRINKLER HEADS AND REQUIRED BRANCH PIPING TO INSTALL IN NEW LOCATION AS BRANCH PIPING TO INSTALL IN NEW LOCATION AS BRANCH PIPING TO INSTALL IN NEW LOCATION AS BRANCH PIPING TO INSTALL IN NEW LOCATION AS SHOWN. SPRINKLER HEAD COLOR TO BE WHITE.SHOWN. SPRINKLER HEAD COLOR TO BE WHITE.SHOWN. SPRINKLER HEAD COLOR TO BE WHITE.SHOWN. SPRINKLER HEAD COLOR TO BE WHITE.LOCATE HEADS IN CENTER OF TILE.LOCATE HEADS IN CENTER OF TILE.LOCATE HEADS IN CENTER OF TILE.LOCATE HEADS IN CENTER OF TILE.3 33 3 N O F I R E S P R I N K L E R W O R K I N T H I S A R E A . NO FIRE SPRINKLER WORK IN THIS AREA.NO FIRE SPRINKLER WORK IN THIS AREA.NO FIRE SPRINKLER WORK IN THIS AREA.PROTECT DURING CONSTRUCTION.PROTECT DURING CONSTRUCTION.PROTECT DURING CONSTRUCTION.PROTECT DURING CONSTRUCTION.4 44 4 R E M O V E E X I S T I N G F I R E S P R I N K L E R P I P I N G I N REMOVE EXISTING FIRE SPRINKLER PIPING IN REMOVE EXISTING FIRE SPRINKLER PIPING IN REMOVE EXISTING FIRE SPRINKLER PIPING IN REMODEL SPACE AS REQUIRED TO REMODEL SPACE AS REQUIRED TO REMODEL SPACE AS REQUIRED TO REMODEL SPACE AS REQUIRED TO ACCOMMODATE THE REMODEL WORK OF ALL ACCOMMODATE THE REMODEL WORK OF ALL ACCOMMODATE THE REMODEL WORK OF ALL ACCOMMODATE THE REMODEL WORK OF ALL TRADES. MAINTAIN EXISTING WHERE FEASIBLE.TRADES. MAINTAIN EXISTING WHERE FEASIBLE.TRADES. MAINTAIN EXISTING WHERE FEASIBLE.TRADES. MAINTAIN EXISTING WHERE FEASIBLE. SC A L E : SC A L E : SC A L E : SC A L E : FP 1 0 1 FP 1 0 1 FP 1 0 1 FP 1 0 1 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" pb ` l k a = i b s b i = j b ` e ^ k f ` ^ i = o b j l a b i mi ^ k 1 11 1 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 C I R C U I T I N G & G E N E R A L S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P TI O N K E Y E D N O TE R E F E R E N C E 1 B R A N C H C I R C U I T H O M E -R U N T O P A N E L I N D I C A TE D A -1 ,3 ,5 3 /4 "C .-6 #1 2 ,1 #1 2 G Q T Y & S I Z E O F E Q U I P M E N T G R O U N D C O N D U C T O R Q T Y & S I Z E O F N E U T R A L A N D P H A S E C O N D U C T O R (S ) S I Z E O F C O N D U I T A -1 ,3 ,5 3 /4 "C .-6 #1 2 ,1 #1 2 G P A N E L A N D C I R C U I T D E S I G N A T I O N S E Q U I P M E N T G R O U N D I N G C O N D U C T O R T I C K M A R K S N E U T R A L C O N D U C T O R (S ) P H A S E A N D /O R S W I T C H -L E G C O N D U C T O R (S ) B R A N C H C I R C U I T /F E E D E R C O N C E A L E D I N C E I L I N G O R W A L L B R A N C H C I R C U I T /F E E D E R C O N C E A L E D U N D E R G R O U N D O R F L O O R N E W E Q U I P M E N T , D E V I C E S , E T C . E X I S T I N G E Q U I P M E N T , D E V I C E S , E T C . D E M O L I T I O N E Q U I P M E N T , D E V I C E S , E T C . D E T A I L # / S H E E T R E F E R E N C E 1 / E S 1 0 1 *2 5 ,0 0 0 A C A L C U L A T E D A V A I L A B L E F A U L T C U R R E N T A T E Q U I P M E N T (S E E P O W E R R I S E R ) F I R E A L A R M S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N D E T E C T O R S U B S C R I P T S P P H O T O E L E C T R I C S M O K E D E T E C T O R D D U C T S M O K E D E T E C T O R I D I N -D U C T S M O K E D E T E C T O R H H E A T D E T E C T O R M M U L T I -S T A T I O N S M O K E D E T E C T O R (1 2 0 V W /B A T T E R Y B A C K U P ) F I R E A L A R M C O N T R O L P A N E L (W A L L M O U N T E D , T O P A T 6 '-0 ' A F F ) F F A C P N O T I F I C A T I O N D E V I C E E X T E N D E R P A N E L . P R O V I D E Q T Y A S R E Q U I R E D B A S E D O N D E V I C E V O L T A G E D R O P C A L C 'S P E R N F P A 7 2 R E Q U I R E M E N T S . (W A L L M O U N T E D , T O P A T 5 '-0 ' A F F ) R E M O T E A N N U C I A T O R P A N E L (F L U S H M O U N T E D I N W A L L A T 5 '-0 ' A F F ) N A C R A M A N U A L P U L L S T A T I O N (M O U N T I N G H E I G H T P E R A D A & N F P A 7 2 ) M A G N E T I C D O O R H O L D O P E N A D D R E S S A B L E C O N T R O L /R E L A Y M O D U L E M MCM A D D R E S S A B L E M O N I T O R I N G M O D U L E F I R E A L A R M F L O W S W I T C H F I R E A L A R M T A M P E R S W I T C H F S T S W A L L M O U N T E D F I R E A L A R M H O R N O N L Y W A L L M O U N T E D F I R E A L A R M S T R O B E O N L Y (C A N D E L A R A T I N G A S I N D I C A T E D ) # A D D R E S S A B L E D E T E C T O R W I T H B A S E #### C E I L I N G M O U N T E D F I R E A L A R M S T R O B E O N L Y (C A N D E L A R A T I N G A S I N D I C A T E D ) #### W A L L M O U N T E D F I R E A L A R M H O R N S T R O B E (C A N D E L A R A T I N G A S I N D I C A T E D ) C E I L I N G M O U N T E D F I R E A L A R M H O R N S T R O B E (C A N D E L A R A T I N G A S I N D I C A T E D ) E X T E R I O R 1 2 0 V F I R E B E L L , I N S T A L L N E X T T O F D C . F I R E /S M O K E D A M P E R ; C O O R D I N A T E L O C A T I O N S W I T H M E C H . D R A W I N G S S D A . D O N O T I N S T A L L M O R E T H A N (1 0 ) N O T I F I C A T I O N A P P L I A N C E S O N A N Y S I N G L E C L A S S "A " S I G N A L C I R C U I T . D O N O T E X C E E D 4 0 0 F T . O F N O . 1 4 W I R E I N T H E T O T A L L O O P . B . N F P A A L L O W S N O T I F I C A T I O N A P P L I A N C E S T O B E M O U N T E D A T A H E I G H T R A N G E B E T W E E N 8 0 " T O 9 6 " A B O V E F I N I S H F L O O R . T H E P R E F E R R E D H E I G H T I S 8 0 ". I F T H I S C O N F L I C T S W I T H O T H E R T R A D E S O R R O O M F U R N I S H I N G S , L O C A T E A S C L O S E T O 8 0 " A S P O S S I B L E , N O T E X C E E D I N G 9 6 ". A L L N O T I F I C A T I O N A P P L I A N C E S I N A C O M M O N R O O M O R L I N E O F S I G H T S H A L L B E L O C A T E D A T A C O M M O N H E I G H T . C . M O U N T P U L L S T A T I O N S A T 4 6 -4 8 " A .F .F . T O T H E O P E R A T I N G H A N D L E T O M E E T A D A R E Q U I R E M E N T S . D . D O N O T C O N N E C T T H E F I R E A L A R M S Y S T E M T O A N Y D E V I C E W H I C H H A S A P O W E R H E L D C O N T A C T S .(F L O W , T A M P E R , H O O D S Y S T E M , D U C T D E T E C T O R , E T C ..F A L S E A L A R M W I L L O C C U R . E . E L E C T R I C A L C O N T R A C T O R S H A L L S U P P L Y A N D I N S T A L L C O N D U C T O R Q U A N T I T I E S P E R F I R E A L A R M S Y S T E M S U P P L I E R , A N D A S P E R N F P A A N D N E C R E Q U I R E M E N T S . F . D O N O T I N S T A L L A N Y S M O K E O R H E A T D E T E C T O R S W I T H I N 3 F E E T O F A N Y A I R D I F F U S E R . G . D O N O T E X C E E D 2 5 0 0 F E E T O N A N Y A D D R E S S A B L E D E V I C E R U N . D O N O T E X C E E D 1 2 0 D E V I C E S O N A N Y O N E A D D R E S S A B L E D E V I C E R U N . H . A L L A I R H A N D L I N G E Q U I P M E N T 2 0 0 0 C F M O R M O R E M U S T B E S H U T D O W N U P O N F I R E A L A R M A S P E R L I F E S A F E T Y C O D E S . I . A L L C L A S S "B " I N I T I A T I N G C I R C U I T S W I T H A D D R E S S A B L E D E V I C E S N E E D E O L R . (E N D O F L I N E R E S I S T O R S ). J . I N C O R R I D O R S , N O T I F I C A T I O N A P P L I A N C E S M U S T B E L O C A T E D W I T H I N 1 5 ' F R O M E N D S O F C O R R I D O R S A N D A M A X I M U M O F 1 0 0 ' S P A C I N G . K . N O T I F I C A T I O N A P P L I A N C E S T O B E S Y N C H R O N I Z E D T O P R O V I D E A 3 -3 -3 T E M P O R A L P A T T E R N . L . A L L W I R I N G A N D C O N D U I T R O U T I N G T O B E A S D E S C R I B E D O N S U P P L I E D S H O P D R A W I N G S . F I R E A L A R M P L A N I S S H O W N F O R G E N E R A L L O C A T I O N A N D L A Y O U T O N L Y . M . T H E F I R E A L A R M S Y S T E M T O B E I N C O M P L I A N C E W I T H A L L A P P L I C A B L E L O C A L , S T A T E A N D A D A R E Q U I R E M E N T S . N . E L E C T . C O N T R . T O C O N N E C T S P R I N K L E R S Y S T E M T A M P E R S W I T C H E S A N D F L O W V A L V E S T O F I R E A L A R M S Y S T E M A S R E Q U I R E D . S E E F I R E S P R I N K L E R S Y S T E M D R A W I N G S F O R E X A C T L O C A T I O N S A N D Q U A N T I T I E S . G E N E R A L F I R E A L A R M S Y S T E M N O T E S L I G H T I N G S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N P A R K I N G A R E A P O L E L I G H T , S I N G L E O R D O U B L E H E A D A S I N D I C A T E D O N D R A W I N G S . R E F E R T O L I G H T P O L E D E T A I L F O R P O L E I N F O R M A T I O N . 2 X 4 F L U O R E S C E N T O R L E D F I X T U R E 2 X 2 F L U O R E S C E N T O R L E D F I X T U R E S U R F A C E M O U N T E D F L U O R E S C E N T O R L E D F I X T U R E S T R I P F L U O R E S C E N T O R L E D F I X T U R E W A L L M O U N T E D F L U O R E S C E N T O R L E D F I X T U R E E X T E R I O R W A L L M O U N T E D F I X T U R E R O U N D R E C E S S E D F I X T U R E S U R F A C E O R P E N D A N T F I X T U R E L I G H T F I X T U R E S U B S C R I P T S N L N I G H T -L I G H T (C O N N E C T T O U N S W I T C H E D L E G O F C I R C U I T ) E X I T S I G N , W A L L O R C E I L I N G M O U N T I N G A S R E Q U I R E D (S I N G L E O R D O U B L E F A C E ) D I R E C T I O N A L C H E V R O N S A S I N D I C A T E D ; C O N N E C T T O U N S W I T C H E D L E G O F L I G H T I N G C I R C U I T T H A T I S I N T H E S A M E A R E A A S T H E E X I T S I G N S . S H A D E D F I X T U R E I N D I C A T E S A N E M E R G E N C Y F I X T U R E . P R O V I D E W I T H E M E R G . B A T T E R Y P A C K O R C O N N E C T T O E M E R G E N C Y P O W E R S Y S T E M (W H E R E A P P L I C A B L E ). C O N N E C T B A T T E R Y P A C K T O U N S W I T C H E D L E G O F L I G H T I N G C I R C U I T T H A T S E R V E S T H E S A M E A R E A A S T H E E M E R G E N C Y F I X T U R E . P R O V I D E W I T H T E S T L I G H T A N D S W I T C H . C E I L I N G M O U N T E D O C C U P A N C Y S E N S O R , R E F E R T O O C C U P A N C Y S E N S O R /S W I T C H S C H E D U L E F O R S E N S O R T Y P E A N D A D D I T I O N A L I N F O R M A T I O N . S W I T C H M O U N T E D O C C U P A N C Y S E N S O R , L O W V O L T A G E S W I T C H P O D O R D I M M E R S W I T C H , R E F E R T O O C C U P A N C Y S E N S O R /S W I T C H S C H E D U L E F O R T Y P E A N D A D D I T I O N A L I N F O R M A T I O N . S I N G L E -P O L E S W I T C H (S E E S U B -S C R I P T S B E L O W F O R A D D I T I O N A L I N F O R M A T I O N ) S W I T C H S U B S C R I P T S 3 3 -W A Y S W I T C H 4 4 -W A Y S W I T C H D D I M M E R S W I T C H (C O M P A T I B L E W / L O A D & L T G T Y P E S ) F 7 -D A Y P R O G R A M M A B L E T I M E R S W I T C H (I N T E R M A T I C M O D E L E I 5 0 0 W C S E R I E S ) P P I L O T L I G H T E D S W I T C H F 1 L I G H T F I X T U R E T Y P E D E S I G N A T I O N S ### W A L L O R C E I L I N G M O U N T E D E M E R G E N C Y L I G H T I N G U N I T W /B A T T E R Y P A C K C O N N E C T T O U N S W I T C H E D L E G O F L I G H T I N G C I R C U I T T H A T I S I N T H E S A M E A R E A A S T H E E M E R G E N C Y L I G H T . L V L O W -V O L T A G E S W I T C H (P E R D W G 'S ) T T H E R M A L -O V E R L O A D S W I T C H M S W I T C H S U P P L I E D W I T H E Q U I P M E N T , I N S T A L L E D B Y E .C . W P W E A T H E R P R O O F 2 P D O U B L E P O L E , S I N G L E T H R O W S W I T C H G E N E R A L L I G H T I N G N O T E S : A . S Y M B O L S S H O W N A B O V E M A Y N O T R E P R E S E N T A L L L I G H T F I X T U R E S U S E D O N P R O J E C T , R E F E R T O L I G H T F I X T U R E S C H E D U L E F O R A C T U A L F I X T U R E I N F O R M A T I O N I N C L U D I N G F I X T U R E T Y P E , L A M P I N G , M O U N T I N G A N D E T C . B . J U N C T I O N B O X E S F O R L I G H T I N G C I R C U I T I N G A R E N O T S H O W N F O R C L A R I T Y . T H E E .C . I S R E S P O N S I B L E F O R P R O V I D I N G A N D I N S T A L L I N G A L L J U N C T I O N B O X E S R E Q U I R E D F O R C I R C U I T I N G O F A L L L I G H T F I X T U R E S T H A T A R E N O T L I S T E D F O R "T H R O U G H -B R A N C H C I R C U I T W I R I N G ". C . I N G E N E R A L A L L S W I T C H -L E G C O N D U C T O R S M A Y N O T B E S H O W N O N D R A W I N G S ; E .C . S H A L L P R O V I D E A N D I N S T A L L C O N D U C T O R S A S R E Q U I R E D T O A C H I E V E C O N T R O L S C H E M E S I N D I C A T E D A N D D E S C R I B E D O N D R A W I N G S . I N C L U D I N G A L L 0 - 1 0 V D I M M I N G C O N T R O L S B E T W E E N S W I T C H A N D F I X T U R E S . D . A L L B A T T E R Y E X I T S I G N S A N D E M E R G E N C Y L I G H T I N G T O B E C O N N E C T E D T O T H E U N S W I T C H E D L E G O F T H E L I G H T I N G C I R C U I T I N T H E A R E A . ### FM P O W E R S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N E L E C T R I C A L S W I T C H B O A R D E Q U I P M E N T , (S E E P O W E R R I S E R A N D P A N E L S C H E D U L E S F O R A D D I T I O N A L I N F O R M A T I O N ) 'M S B ' 'T ##' D R Y -T Y P E T R A N S F O R M E R , (S E E P O W E R R I S E R F O R A D D I T I O N A L I N F O R M A T I O N ) 'L A ' E L E C T R I C A L P A N E L B O A R D , (S E E P O W E R R I S E R A N D P A N E L S C H E D U L E S F O R A D D I T I O N A L I N F O R M A T I O N ) D I S C O N N E C T S W I T C H , S I Z E /P O L E S /T Y P E A S I N D I C A T E D T Y P E S : 1 =N E M A 1 , 3 R =N E M A 3 R , 4 X =N E M A 4 X 3 0 A /3 P /3 R F U S E D D I S C O N N E C T S W I T C H , S I Z E /P O L E S /T Y P E A S I N D I C A T E D T Y P E S : 1 =N E M A 1 , 3 R =N E M A 3 R , 4 X =N E M A 4 X 3 0 A /3 P /3 R (3 0 A F U S E S ) C O M B I N A T I O N S T A R T E R & F U S E D D I S C O N N E C T S W I T C H , S I Z E /P O L E S /T Y P E A S I N D I C A T E D . T Y P E S : 1 =N E M A 1 , 3 R =N E M A 3 R , 4 X =N E M A 4 X J J U N C T I O N B O X C R = C O R D R E E L ; S E E D R A W I N G S F O R I N F O R M A T I O N C D = C O R D D R O P ; S E E D R A W I N G S F O R I N F O R M A T I O N E Q U I P M E N T C O N N E C T I O N ; C O O R D I N A T E C O N N E C T I O N W I T H E Q U I P M E N T P R I O R T O R O U G H -I N M O T O R C O N N E C T I O N P O W E R A N D /O R D A T A S E R V I C E P O L E F L O O R B O X (S E E F L O O R B O X S C H E D U L E F O R A D D I T I O N A L I N F O R M A T I O N ) P U S H B U T T O N S T A T I O N F B # S P E C I A L R E C E P T A C L E (C O O R D I N A T E N E M A T Y P E W I T H E Q U I P .) (R E F E R T O P A N E L S C H E D U L E S F O R A M P S ) C E I L I N G M O U N T E D D U P L E X R E C E P T A C L E (C O O R D I N A T E P L A C E M E N T W I T H C E I L I N G E Q U I P M E N T P R I O R T O R O U G H -I N ) D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E M O U N T E D B E L O W 5 F T G F C I -T Y P E D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E M O U N T E D B E L O W 5 F T D O U B L E -D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E M O U N T E D B E L O W 5 F T G F C I -T Y P E D O U B L E -D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E M O U N T E D B E L O W 5 F T . R E C E P T A C L E A N D E Q U I P M E N T S U B S C R I P T S A C A B O V E C O U N T E R W P W E A T H E R P R O O F (U L L I S T E D W E A T H E R -R E S I S T A N T ) 4 2 " M O U N T I N G H E I G H T A F F O R A F G I G I S O L A T E D G R O U N D S S U R G E -P R O T E C T I O N T Y P E R E F R E F R I G E R A T O R W W A S H I N G M A C H I N E D D R Y E R (3 0 A -2 4 0 V R A T E D R E C P T .) M M I C R O W A V E H V A C T H E R M O S T A T O R S E N S O R ; P R O V I D E & I N S T A L L B A C K B O X ,3 /4 " C O N D U I T A N D C O N D U C T O R S T O A S S O C I A T E D H V A C U N I T . C O O R D I N A T E E X A C T L O C A T I O N & S I Z E A N D N U M B E R O F C O N D U C T O R S W I T H M .C . T S O R 3 0 A /3 P /3 R S I Z E 1 (3 0 A F U S E S ) S M A L L E X H A U S T F A N C O N N E C T I O N T V 1 2 0 V R E C E P T . F O R T V ; V E R I F Y H E I G H T W I T H A R C H . D R A W I N G S & E L E V A T I O N S U S B 1 2 0 V R E C P T . W I T H U S B C H A R G I N G P O R T S E W C E L E C T R I C W A T E R C O O L E R ; (S E E D E T A I L . R E C P T . S H A L L B E A C C E S S I B L E , D O N O T M O U N T B E H I N D H O U S I N G .) D I S P G A R B A G E D I S P . (U N D E R S I N K ) D W D I S H W A S H E R (C O O R D I N A T E W / M I L L W O R K , I N S T A L L P E R N E C 4 2 2 .1 6 (B )(2 )). M /R M I C R O W A V E /R A N G E H O O D (C O O R D I N A T E W / M I L L W O R K ) R E L E C T R I C R A N G E (5 0 A -2 4 0 V R A T E D R E C P T .) G E N E R A L S P E C I A L S Y S T E M N O T E S : A . A L L D E V I C E S S H O W N A T O R N E A R M I L L W O R K /C A S E W O R K S H A L L B E C O O R D I N A T E D W I T H T H E A R C H I T E C T U R A L E L E V A T I O N D R A W I N G S A N D M I L L W O R K I N S T A L L E R T O I N S U R E P R O P E R M O U N T I N G H E I G H T S . C O N T R A C T O R S H A L L A D J U S T D E V I C E S A S N E C E S S A R Y I N O R D E R T O P O S I T I O N D E V I C E S S U C H T H A T T H E Y W I L L N O T F A L L B E H I N D M I L L W O R K , C A B I N E T S O R B E D I R E C T L Y A B O V E S I N K S O R M I D W A Y B E T W E E N T I L E W O R K /W A L L O R W A I N S C O A T I N G , E T C . B . I T S H A L L B E T H E R E S P O N S I B I L I T Y O F T H E C O N T R A C T O R T O I N S T A L L A G F C I T Y P E R E C E P T A C L E F O R A L L R E C P T A C L E S S H O W N I N T O I L E T R M S , B A T H R O O M S , K I T C H E N S /S E R V I N G A R E A S , R O O F T O P , O U T D O O R S O R W I T H I N 6 F T O F A N Y S I N K , B A S I N , T U B O R F L O O R S I N K A N D A L L O T H E R A R E A S D E F I N E D B Y T H E N E C . S P E C I A L S Y S T E M S S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N D A T A O U T L E T ; _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _D -X T E L E P H O N E O U T L E T ; _= # O F T E L E P H O N E C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _T -X T E L E P H O N E /D A T A O U T L E T ; _= # O F T E L E P H O N E /D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _T /_D -X C E I L I N G M O U N T E D D A T A O U T L E T ; _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _D -X A . C O M M U N I C A T I O N S C A B L E S S H A L L H A V E B E N D S N O G R E A T E R T H A N 9 0 D E G . B . C O N D U I T S F O R C O M M U N I C A T I O N S C A B L I N G S H A L L H A V E A M A X I M U M B E N D R A D I U S N O T M O R E T H A N 1 0 X T H E D I A M E T E R O F T H E C O N D U I T . C . A L L C O M M U N I C A T I O N S C O N D U I T S S H A L L B E T E R M I N A T E D W I T H A N I N S U L A T E D N O N -M E T A L L I C B U S H I N G A T B O T H E N D S . D . C O M M U N I C A T I O N S C O N D U I T S S H A L L H A V E N O M O R E T H A N (2 ) 9 0 'S W I T H O U T A P U L L B O X . P U L L B O X E S S H A L L B E L O C A T E D I N A C C E S S I B L E L O C A T I O N S A N D S H A L L B E S I Z E D A T L E A S E D 1 2 X T H E L A R G E S T C O N D U I T D I A M E T E R I N L E N G T H A N D M I N , 4 " D E E P A N D 8 " W I D E . E . I T S H A L L B E T H E R E S P O N S I B I L I T Y O F T H E E .C . T O I N S U R E T H A T T H E P A T H W A Y F O R T H E D A T A C A B L I N G D O E S N O T C R E A T E C A B L E L E N G T H S T O E X C E E D S T H E L E N G T H O F 2 9 5 F T F R O M O U T L E T T O P A T C H P A N E L , T H I S I N C L U D E S S E R V I C E L O O P S A N D P A T C H C O R D S . F . W H E R E C A B L E T R A Y I S U T I L I Z E D I N T H E P R O J E C T . C O M M U N I C A T I O N C O N D U I T S E N D I N G A T T H E C A B L E T R A Y S H A L L E X T E N D 1 " O V E R T H E S I D E I N T O T H E T R A Y . G E N E R A L S P E C I A L S Y S T E M N O T E S : ### _D -X S P E C I A L S Y S T E M S N O T E S : 1 . U T I L I Z E 4 1 1 /1 6 " D E E P B O X W I T H R E Q U I R E D M U D R I N G A N D C O N D U I T T O A B O V E N E A R E S T A C C E S S I B L E C E I L I N G O R D A T A R A C K , T E R M I N A T E W I T H I N S U L A T E D T H R O A T B U S H I N G . P R O V I D E Q T Y O F C A B L E S I N D I C A T E D F R O M O U T L E T T O N E A R E S T T E L E /D A T A R O O M . S E E D W G S F O R A D D I T I O N A L I N F O R M A T I O N . U T I L I Z E J -H O O K S 3 F T O N C E N T E R F O R S U P P O R T O F C A B L I N G W H E R E C A B L E T R A Y I S N O T I N S T A L L E D /S P E C I F I E D . 2 . C O N D U I T S I Z E ('X ' F R O M A B O V E ); 2 =1 /2 ", 3 =3 /4 ", 4 =1 ", 5 =1 -1 /4 ", 6 =1 -1 /2 " 3 . B L A N K (N O L A B E L ) = 4 -1 1 /1 6 " D E E P B O X W I T H R E Q U I R E D M U D R I N G A N D 1 " C O N D U I T T O A B O V E N E A R E S T A C C E S S I B L E C E I L I N G /C A B L E T R A Y , T E R M I N A T E W I T H I N S U L A T E D T H R O A T B U S H I N G , P R O V I D E P U L L S T R I N G . (U N L E S S O T H E R W I S E N O T E D ) W A L L P A T H W A Y S Y S T E M ; S T I F I R E S T O P E Z -P A T H S E R I E S I N S T A L L T H R O U G H W A L L A B O V E A C C E S S I B L E C E I L I N G , F I E L D V E R I F Y E X A C T L O C A T I O N T O A V O I D C O N F L I C T W I T H O T H E R T R A D E S A N D U T I L I T I E S . P R O V I D E A L L R E Q U I R E M O U N T I N G H A R D W A R E A N D E T C . F O R C O M P L E T E I N S T A L L A T I O N . E P F 2 = F I R E R A T E D , E Z -P A T H S E R I E S 2 2 E P F 3 = F I R E R A T E D , E Z -P A T H S E R I E S 3 3 E P F 4 = F I R E R A T E D , E Z -P A T H S E R I E S 4 4 E P 3 = N O N -F I R E R A T E D , E Z -P A T H 3 3 N E Z S E R I E S ### F B # _D -X E L E C T R I C A L F L O O R B O X R E F E R T O "E L E C T R I C A L F L O O R B O X S C H E D U L E " F O R I N F O R M A T I O N . _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) T V A N D /O R A V B O X ; W I T H P O W E R , D A T A A N D /O R A V C O N N E C T I V I T Y ### = B O X I D : R E F E R T O "E L E C T R I C A L A V /T V B O X S C H E D U L E " F O R I N F O R M A T I O N . _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E #2 B E L O W ) I N S T A L L C O N D U I T (S I Z E A S I N D I C A T E D ) F R O M B O X T O N E A R E S T A C C E S S I B L E C E I L I N G S P A C E W / D A T A C A B L I N G /T E R M I N A T I O N S A S I N D I C A T E D O N D R A W I N G S . P 1 P H 2 /C 3 /C 3 P 3 P H 3 W 4 W A C A D A A F F A F G A I C A L A o r A M P A N N A P A T S A V A W G B F G C C A T V C B C C T V C K T C C P C T C U D S E A E .C .E M E M T E N T E P O E Q U I P E X F A F A C P F L A F M C G N D G .C .G E N G F I G F P H D H I D H O A H P H P S H V H Z I G I M C J -B O XABBREVIATIONSSINGLE P O L E S I N G L E -P H A S E T W O -C O N D U C T O R T H R E E -C O N D U C T O R T H R E E P O L E T H R E E -P H A S E T H R E E -W I R E F O U R -W I R E A B O V E C O U N T E R A M E R I C A N S W I T H D I S A B I L I T I E S A C T A B O V E F I N I S H E D F L O O R A B O V E F I N I S H E D G R A D E A M P E R E I N T E R R U P T I N G C A P A C I T Y A L U M I N U M A M P E R E A N N U N C I A T O R A C C E S S P O I N T (W I R E L E S S D A T A )A U T O M A T I C T R A N S F E R S W I T C H A U D I O V I S U A L A M E R I C A N W I R E G A G E B E L O W F I N I S H E D G R A D E C E I L I N G M O U N T E D C A B L E T E L E V I S I O N C I R C U I T B R E A K E R C L O S E D C I R C U I T T E L E V I S I O N C I R C U I T C O N D U I T C O N T R O L P A N E L C U R R E N T T R A N S F O R M E R C O P P E R D I S C O N N E C T S W I T C H E A C H E L E C T R I C A L C O N T R A C T O R E M E R G E N C Y E L E C T R I C A L M E T A L L I C T U B I N G E L E C T R I C A L N O N M E T A L L I C T U B I N G E M E R G E N C Y P O W E R O F F E Q U I P M E N T E X I S T I N G F I R E A L A R M F I R E A L A R M C O N T R O L P A N E L F U L L L O A D A M P S F L E X I B L E M E T A L C O N D U I T G R O U N D G E N E R A L C O N T R A C T O R G E N E R A T O R G R O U N D F A U L T C I R C U I T I N T E R R U P T E R G R O U N D F A U L T P R O T E C T I O N H E A V Y D U T Y H I G H I N T E N S I T Y D I S C H A R G E H A N D -O F F -A U T O M A T I C H O R S E P O W E R H I G H P R E S S U R E S O D I U M H I G H V O L T A G E H E R T Z I S O L A T E D G R O U N D I N T E R M E D I A T E M E T A L C O N D U I T J U N C T I O N B O XVKVAkWkWhLEDLFMCLFNCLTGLVMAXM.C .M C A M C B M C C M D P M H M I N M L O M O C P N A N C N E C N E M A N F P A N I C N L N O N T S O C O H D R O L P B P P N L P T P T Z Q T Y R C P R M C R N C S C A S C B A S F S P D S P E C S W B D S W G R T L T P T T B T V T Y P U G U P S V V A V .I .F .V F D W A P W /W /O W P X F M RKILOVOLTKILOVOLT A M P E R E K I L O W A T T K I L O W A T T H O U R L I G H T E M I T T I N G D I O D E L I Q U I D T I G H T F L E X I B L E M E T A L C O N D U I T L I Q U I D T I G H T F L E X I B L E N O N M E T A L L I C C O N D U I T L I G H T I N G L O W V O L T A G E M A X I M U M M E C H . C O N T R A C T O R M I N I M U M C I R C U I T A M P S M A I N C I R C U I T B R E A K E R M O T O R C O N T R O L C E N T E R M A I N D I S T R I B U T I O N P A N E L M A N H O L E M I N I M U M M A I N L U G S O N L Y M A X I M U M O V E R C U R R E N T P R O T E C T I O N N O T A P P L I C A B L E N O R M A L L Y C L O S E D N A T I O N A L E L E C T R I C A L C O D E N A T I O N A L E L E C T R I C A L M A N U F A C T U R E R S A S S O C I A T I O N N A T I O N A L F I R E P R O T E C T I O N A S S O C I A T I O N N O T I N C O N T R A C T N I G H T L I G H T N O R M A L L Y O P E N N O T T O S C A L E O N C E N T E R O V E R H E A D D O O R O V E R L O A D P U S H B U T T O N P H A S E P A N E L P O T E N T I A L T R A N S F O R M E R P A N /T I L T /Z O O M Q U A N T I T Y R E F L E C T E D C E I L I N G P L A N R I G I D M E T A L C O N D U I T R I G I D N O N M E T A L L I C C O N D U I T S H O R T C I R C U I T A M P S S T A N D A R D C O L O R B Y A R C H I T E C T S Q U A R E F O O T (F E E T )S U R G E P R O T E C T I O N D E V I C E S P E C I F I C A T I O N S W I T C H B O A R D S W I T C H G E A R T W I S T L O C K T W I S T E D P A I R T E L E P H O N E T E R M I N A L B O A R D T E L E V I S I O N T Y P I C A L U N D E R G R O U N D U N I N T E R R U P T I B L E P O W E R S U P P L Y V O L T S V O L T A M P E R E V E R I F Y I N F I E L D V A R I A B L E F R E Q U E N C Y D R I V E W I R E L E S S A C C E S S P O I N T W I T H W I T H O U T W E A T H E R P R O O F T R A N S F O R M E R A . E .C . S H A L L R E F E R T O T H E M E C H A N I C A L D R A W I N G S F O R E X A C T L O C A T I O N S O F A L L M E C H A N I C A L E Q U I P M E N T A N D E L E C T R I C A L C O N N E C T I O N S . B . E .C . S H A L L P R O V I D E M I N I M U M W O R K I N G C L E A R A N C E A S P E R N E C B E F O R E I N S T A L L I N G A N Y E L E C T R I C A L P A N E L S O R C A B I N E T S . S E E E L E C T R I C A L E Q U I P M E N T C L E A R A N C E D E T A I L . C . I N S T A L L A L L L I G H T F I X T U R E S I N M E C H A N I C A L R O O M A F T E R T H E M E C H A N I C A L E Q U I P M E N T I S I N P L A C E . A D J U S T A S N E C E S S A R Y . P R O V I D E C H A I N S U S P E N S I O N K I T S A S R E Q U I R E D . D . R E F E R T O A R C H I T E C T U R A L R E F L E C T E D C E I L I N G P L A N (S ) F O R E X A C T F I X T U R E L O C A T I O N S , C E I L I N G T Y P E S , E T C . E . E .C . S H A L L P R O V I D E A L L C O N C R E T E P A D S A S R E Q U I R E D F O R A L L E L E C T R I C A L E Q U I P M E N T . F . C O N F I R M E X A C T L O C A T I O N S O F A L L T E L E P H O N E /D A T A O U T L E T S W I T H O W N E R P R I O R T O R O U G H -I N . G . L O C A T E S W I T C H E S , O U T L E T S , E T C ., S H O W N A T R O O M E N T R Y D O O R W A Y S , A S C L O S E T O D O O R F R A M E A S P O S S I B L E , S O A S N O T R O I N T E R F E R E W I T H R O O M C A B I N E T S , E T C . H . S U P P O R T A L L L I G H T F I X T U R E S I N D E P E N D E N T O F C E I L I N G . I . E L E C T R I C A L C O N T R A C T O R S H A L L O B T A I N A L L A P P L I C A B L E P E R M I T S F O R W O R K A N D P A Y A S S O C I A T E D F E E S . J . M A I N T A I N 2 4 " M I N . C L E A R A N C E F R O M A L L C O M M U N I C A T I O N S C A B L I N G A N D E L E C T R O N I C B A L L A S T S . K . U N L E S S S P E C I F I C A L L Y I N D I C A T E D O T H E R W I S E , E .C . S H A L L C O O R D I N A T E W I T H A N Y S P E C I A L S Y S T E M S S U P P L I E R /S H O P D R A W I N G S ; D E N T A L , M E D I C A L , K I T C H E N , S P E C I A L I Z E D E Q U I P M E N T , E T C . F O R T H E E X A C T R O U G H -I N R E Q U I R E M E N T S F O R T H E I R E Q U I P M E N T . A L S O U N L E S S I N D I C A T E D O T H E R W I S E , T H E E .C . T O B E R E S P O N S I B L E F O R F I N A L E L E C T R I C A L C O N N E C T I O N S T O A L L S P E C I A L E Q U I P M E N T . L . A L L C O N D U I T /R A C E W A Y /C A B L E S T O B E C O N C E A L E D I N W A L L S O R A B O V E C E I L I N G S . I F A N Y S U R F A C E W O R K I S N E C E S S A R Y , I T S H A L L B E A P P R O V E D B Y T H E A R C H I T E C T /E N G I N E E R P R I O R T O I N S T A L L A T I O N . M . E L E C T R I C A L C O N T R A C T O R S H A L L V I S I T T H E S I T E P R I O R T O B I D A N D T H O R O U G H L Y I N V E S T I G A T E T H E E X I S T I N G C O N D I T I O N S , A S T H E Y R E L A T E T O T H E S C O P E O F W O R K D E S C R I B E D . M A K E N E C E S S A R Y P R O V I S I O N S I N T H E B A S E B I D T O A D E Q U A T E L Y A C C O M M O D A T E T H E S E C O N D I T I O N S . N . D A T A C A B L I N G S Y S T E M P R E -I N S T A L L A T I O N C O N F E R E N C E : 1 . E .C . S H A L L S C H E D U L E A M E E T I N G A M I N I M U M O F F I V E C A L E N D A R D A Y S P R I O R T O B E G I N N I N G D A T A C A B L I N G I N S T A L L A T I O N . A T T E N D E E S S H O U L D I N C L U D E O W N E R ’S R E P ., E N G I N E E R , G C , E C A N D C A B L I N G S U B . R E F E R T O S E C T I O N 2 6 6 2 1 0 (1 .4 )(E ) F O R A D D I T I O N A L I N F O R M A T I O N . P R O J E C T G E N E R A L N O T E S : I D A H O P O W E R C O . R O C K Y M O U N T A I N P O W E R C O . W W W .I D A H O P O W E R .C O M W W W .R O C K Y M O U N T A I N P O W E R .N E T C O N T A C T : C O N T A C T : S H E L L E Y M A R T I N (2 0 8 ) 3 8 8 -5 8 7 2 D A N K U H L (5 0 3 ) 3 0 8 -0 2 3 3 O R D A N K U H L (5 0 3 ) 3 0 8 -0 2 3 3 d a n .k u h l @ e v e r g r e e n -e f f i c i e n c y .c o m d a n .k u h l @ e v e r g r e e n -e f f i c i e n c y .c o m U T I L I T Y L I G H T I N G R E B A T E S & I N C E N T I V E S : I T S H A L L B E T H E R E S P O N S I B I L I T Y O F T H E E L E C T R I C A L C O N T R A C T O R T O P R E P A R E A L L R E Q U I R E D A P P L I C A T I O N S A N D I N F O R M A T I O N R E Q U I R E D T O P R O V I D E T H E O W N E R W I T H T H E M A X I M U M A M O U N T O F R E B A T E D O L L A R S F R O M T H E L O C A L U T I L I T Y C O M P A N Y . T H E E L E C T R I C A L C O N T R A C T O R S H A L L S U B M I T V E R I F I C A T I O N O F T H E U T I L I T Y C O M P A N Y P R E -A P P L I C A T I O N A P P R O V A L P R I O R T O O R D E R I N G A N Y M A T E R I A L S . V I S I T T H E F O L L O W I N G U T I L I T Y C O . W E B S I T E S F O R I N F O R M A T I O N : T Y P I C A L D E V I C E M O U N T I N G H E I G H T S : G E N E R A L C O O R D I N A T I O N N O T E : G E N E R A L D E T A I L N O T E S : F I N I S H F L O O R 1 ' - 6 '' T H E R M O S T A T O R S E N S O R V E R I F Y W I T H M .C . P R I O R T O L I G H T S W . (O R A S N O T E D ) * 4 ' - 0 '' * 3 ' - 6 '' (O R A S N O T E D ) R E C E P T A C L E @ M I L L W O R K B A C K S P L A S H C A B . D I M E N S I O N S P E R A R C H . D E T A I L 6 " C A B I N E T * E .C . S H A L L C O O R D I N A T E A L L D E V I C E M O U N T I N G H G T S . A N D E X A C T L O C A T I O N W I T H A R C H I T E C T U R A L I N T E R I O R E L E V A T I O N S R E P O R T C O N F L I C T S T O A R C H I T E C T **P R I O R T O R O U G H -I N ** R O U G H -I N . T Y P I C A L F O R A L L D E V I C E S M O U N T E D A B O V E C O U N T E R (i e C .O .'S , D A T A , P H O N E e t c .) A .B .C .D . A L L M O U N T I N G H E I G H T S T Y P I C A L U N L E S S N O T E D O T H E R W I S E . C O O R D I N A T E O U T L E T H E I G H T S W I T H A R C H I T E C T S M I L L W O R K D W G S . T O I N S U R E T H A T O U T L E T S W I L L N O T F A L L B E H I N D C A B I N E T S , B A C K S P L A S H E S , O R I N T E R F E R E W I T H W A I N S C O T I N G , E T C . A L L S W I T C H E S A N D T H E R M O S T A T S T O B E M O U N T E D A S C L O S E T O D O O R J A M S A S P O S S I B L E . C O O R D I N A T E A L L D E V I C E S W I T H A R C H I T E C T U R A L P L A N S A N D D E T A I L S . C O O R D I N A T E L I G H T S W I T C H & O U T L E T H E I G H T S W I T H A R C H I T E C T U R A L W A I N S C O T I N G A N D O R T I L E W O R K S O A S N O T T O F A L L M I D W A Y I N T H E S E F I N I S H E S . F I R E 6 ' - 8 '' F I R E A L A R M N O T I F I C A T I O N D E V I C E F I R E M A N U A L P U L L S T A T I O N H A N D L E S H A L L B E B E T W E E N 4 2 " & 4 8 " A F F C A B I N E T R E C E P T . T E L E /D A T A O U T L E T T V O U T L E T E L E C T R I C A L E Q U I P . C L E A R A N C E E L E C T R I C A L E Q U I P M E N T NOTE #1 N O T E #4NOTE#3 N O T E #2 N O T E S :1 . T H E M I N I M U M H E A D R O O M O F W O R K I N G S P A C E S H A L L B E 6 1 /2 F T .2 . T H E W I D T H O F T H E W O R K I N G S P A C E S H A L L B E T H E W I D T H O F T H E E Q U I P M E N T O R 3 0 ", W H I C H E V E R I S G R E A T E R . T H E P A N E L D O O R S H A L L O P E N A T L E A S T 9 0 D E G R E E S .3 . A L L C I R C U I T B R E A K E R S , W H E N I N T H I E R H I G H E S T P O S I T I O N , S H A L L N O T B E M O R E T H A N 6 F T 7 I N . A B O V E T H E F I N I S H E D F L O O R .4 . 3 F T C L E A R A N C E I F 0 -1 5 0 V T O G R O U N D , 3 .5 F T C L E A R A N C E I F 1 5 1 -6 0 0 V T O G R O U N D . 4 F T I F E X P O S E D L I V E P A R T S O N B O T H S I D E S O F T H E W O R K I N G S P A C E .G E N E R A L N O T E S :A . A L L W O R K I N G S P A C E C L E A R A N C E S A R E F R O M T H E F A C E O F T H E E Q U I P M E N T .8 2 7 0 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E . C e n t e r P o c a t e l l o , I d a h o 8 3 2 0 1 t e l (2 0 8 ) 2 3 2 -4 4 3 9 w w w .p a y n e e n g i n e e r i n g i n c .c o mEngineering I n c .C o n s u l t i n g E n g i n e e r s3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 s h e e t :t i t l e :r e v i s i o n s :p r o j e c t # :d a t e :U N L E S S A P R O F E S S I O N A L S E A L W I T H S I G N A T U R E A N D D A T E I S A F F I X E D , T H I S D O C U M E N T I S P R E L I M I N A R Y A N D I S N O T I N T E N D E D F O R C O N S T R U C T I O N , R E C O R D I N G P U R P O S E S , O R I M P L E M E N T A T I O N T H E D E S I G N S S H O W N A N D D E S C R I B E D H E R E I N I N C L U D I N G A L L T E C H N I C A L D R A W I N G S , G R A P H I C R E P R E S E N T A T I O N S & M O D E L S T H E R E O F , A R E P R O P R I E T A R Y & C A N N O T B E C O P I E D , D U P L I C A T E D , O R C O M M E R C I A L L Y E X P L O I T E D I N W H O L E O R I N P A R T W I T H O U T T H E S O L E A N D E X P R E S S W R I T T E N P E R M I S S I O N F R O M M E T H O D S T U D I O I N C .p r o j e c t : E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P .E . #:2 2 2 6 0 3 -2 5 -2 2 E G 1 0 0ELECTRICALSYMBOLS &D E T A I L SMarch 2 5 , 2 0 2 2[ S E T P R O J E C T I N F O R M A T I O N A D D R E S S T E X T F I E L D A N D S E T L O C A T I O N U N D E R E N E R G Y S E T T I N G S I F A P P L I C A B L E ]B Y U I M A N W A R I N G W E L C O M E C E N T E R R E M O D E L B i d S e t S E C U R I T Y & A C C E S S C O N T R O L S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N C A R D R E A D E R /K E Y P A D L O C A T I O N ; U T I L I Z E 4 S Q . B O X W /1 -G A N G M U D R I N G A N D 3 /4 "C . W / P U L L S T R I N G T O N E A R E S T A C C E S S I B L E C E I L I N G S P A C E . C R C A M S E C U R I T Y C A M E R A : P R O V I D E A N D I N S T A L L A 4 S Q . B O X W /3 /4 "C ., T O N E A R E S T A C C E S S I B L E C E I L I N G S P A C E & 1 -C A T 6 A C A B L E T O I T R O O M . T E R M I N A T E J A C K O N T H E C A B L E F O R C A M E R A . C A M E R A T O B E P R O V I D E D A N D I N S T A L L E D B Y O W N E R O V E R B O X ; C O O R D I N A T E R O U G H -I N W I T H O W N E R C A M E R A S P E C . C O O R D I N A T E M O U N T I N G H E I G H T W / O W N E R P R I O R T O R O U G H I N . C O N N E C T I O N T O D O O R F R A M E F O R A C C E S S C O N T R O L . P R O V I D E (1 )3 /4 "C W /P U L L S T R I N G F R O M D O O R T O N E A R E S T A C C E S S S I B L E C E I L I N G S P A C E . • E .C . I S R E S P O N S I B L E F O R R O U G H -I N F O R A C C E S S C O N T R O L S Y S T E M ; E Q U I P M E N T A N D C A B L I N G T O B E P R O V I D E D A N D I N S T A L L E D B Y O W N E R . E .C . S H A L L C O O R D I N A T E R O U G H -I N O F A C C E S S C O N T R O L S Y S T E M W I T H B Y U -I P R I O R T O R O U G H -I N . • E .C . I S R E S P O N S I B L E F O R R O U G H -I N , C A B L I N G A N D T E R M I N A T I O N S F O R S E C U R I T Y C A M E R A 'S . C A M E R A S W I L L B E P R O V I D E D A N D I N S T A L L E D B Y B Y U -I . E .C . S H A L L C O O R I N A T E L O C A T I O N S A N D R O U G H -I N W I T H B Y U -I P R I O R T O W O R K B E I N G D O N E . G E N E R A L S E C U R I T Y & A C C E S S C O N T R O L N O T E S : F F A 1 2 3 4 5 6 7 B C D E AR E A O U T O F S C O P E AR E A O U T O F S C O P E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 6 1 2 3 4 5 6 7 B C D E LO W V O L T A G E S W I T C H B A N K 1 1(TYP)(TYP) 1 1 (TYP) (T Y P ) 2 2 2 3 3 3A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERW ISE, ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH -IN, ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND COVERS.B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES.C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED.D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SH ALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC.E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER.F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC.G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK.H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEN D AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING.J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANIC AL EQUIPMENT TO BE REMOVED OR RELOCATED.K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS.L. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITIO N AND COMPLIES WITH SPECIFICATIONS.M. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS.N. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS.GENERAL NOTES: 1 D I S C O N N E C T A N D R E M O V E E X I S T I N G L I G H T I N G I N T H I S A R EA: RE M O V E U N U S E D A S S O C I A T E D C O N T R O L S , W I R E A N D CO N D U I T , M A I N T A I N E X I S T I N G N O R M A L A N D E M E R G E N C Y LI G H T I N G C I R C U I T S A N D C O N T R O L S F O R U S E W I T H N E W LI G H T I N G . M A I N T A I N A N D / O R R E - E S T A B L I S H E L E C T R I C A L CO N T I N U I T Y T O D O W N S T R E A M D E V I C E S T O R E M A I N . 2 D I S C O N N E C T A N D R E M O V E E X I S T I N G L I G H T I N G I N T H I S A R EA: RE M O V E A L L A S S O C I A T E D C O N T R O L S , W I R E A N D C O N D U I T , MA I N T A I N E X I S T I N G N O R M A L A N D E M E R G E N C Y L I G H T I N G CI R C U I T S F O R U S E W I T H N E W L I G H T I N G . M A I N T A I N A N D / O R RE - E S T A B L I S H E L E C T R I C A L C O N T I N U I T Y 3 E X I S T I N G E X I T S I G N T O R E M A I N P R O T E C T D U R I N G CO N S T R U C T I O N . M A I N T A I N A N D / O R R E - E S T A B L I S H P O W E R T O FI X T U R E 4 E X I S T I N G D E V I C E T O R E M A I N . P R O T E C T A N D / O R RE - E S T A B L I S H C O N T I N U I T Y T O D E V I C E D U R I N G CO N S T R U C T I O N . M O D I F Y M O U N T I N G A S N E E D E D T O AC C O M M O D A T E N E W C O N S T R U C T I O N . 5 E X I S T I N G F I R E A L A R M D E V I C E T O R E M A I N E . C . S H A L L PR O T E C T D U R I N G C O N S T R U C T I O N . 6 E X I S T I N G F I R E A L A R M D E V I C E T O R E M A I N , C A R E F U L L Y RE M O V E A N D C L E A N D E V I C E . R E I N S T A L L D E V I C E O N C E W A L L IS C O M P L E T E . KE Y N O T E S : # 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:2226 03-25-22 ED100EXISTINGELECTRICALPLANMarch 25, 2022[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]BYUI MANWARING WELCOME CENTER REMODEL Bid Set SC A L E : 1 / 8 " = 1 ' - 0 " 1 EX I S T I N G P O W E R P L A N SC A L E : 1 / 8 " = 1 ' - 0 " 2 EX I S T I N G L I G H T I N G P L A N 16 ' 8' 0" 16'8'0" NO R T H NORTH GE N E R A L N O T E : CI R C U I T I N G I S B A S E D O N BU I L D I N G R E C O R D DR A W I N G S . E . C . S H A L L FI E L D V E R I F Y E X I S T I N G CO N D I T I O N S P R I O R T O RO U G H I N . N O T I F Y G . C . AN D E N G I N E E R O F A N Y CO N F L I C T S J J J J J J J F J J J J C A M CA M C A M CA M n 2 D n1 n1 n 1 S nD 1 S nD 1 S nD 1 1 2 3 4 5 6 7 B C D E WE L C O M E RO O M [3 ] ST O R A G E [4 ] EX I S T I N G ST O R A G E [9 ] CO R R I D O R B [1 2 ] WE L C O M E / HE L P D E S K [7 ] SE A T I N G B [6 ] SE A T I N G A [5 ] CO R R I D O R A [1 0 ] 2D -3 2D -3 2D -3 AR E A O U T O F S C O P E AR E A O U T O F S C O P E 1 1 1 2D -3 AC AC 2 2 6D -5 3 4 4 4 DA T A 27 0 6 3D -4 3D -4 3D -4 3D -4 3D -4 '2 2 L 4 ' '2 2 U P ' 2D -3 2D -3 1D -3 7 8 '2 2 L 4 ' '2 2 U P ' '2 2 U P ' '2 2 L 4 ' 6 6 6 '2 2 L 4 ' 6 18 " 18 " 9 '2 2 L 4 ' '2 2 L 4 ' 6 6 6 '2 2 L 4 ' 12 12 1 2 3 4 5 6 7 B C D E WE L C O M E RO O M [3 ] ST O R A G E [4 ] EX I S T I N G ST O R A G E [9 ] SE A T I N G A [5 ] SE A T I N G B [6 ] WE L C O M E / HE L P D E S K [7 ] CORRIDOR B [12]CORRIDOR A [10] a F1 (T Y P ) F1 F1 (TYP)F1 (T Y P ) F2 F2 F2 (T Y P ) F2 F2 (T Y P ) F2 F1 (T Y P ) F1 F1 F1 F1 F1 5 5 a a a a aaa b b b b b b b b b b b b 10 10 F1 F1 F1 F1F1F1 F1 E F1 E F1 E F1EF1EF1E F2 E F2 E F2 E F2 E F2EF1E F1 E F3 F3 F1 F1 E 11 11 A. COORDINATE LIGHT FIXTURE LOCATION WITH ARCHITECTURAL CEILING PLAN, MECHANICAL GRILLES, DIFFUSERS, SPEAKERS, ETC. LOCATE ALL LIGHT FIXTURES IN MECHANICAL EQUIPMENT ROOMS AFTER ALL MECH. EQUIPMENT IS INSTALLED. ADJUST AS NECESSARY TO MISS PIPING, DUCTS, FILTER ACCESS PANELS, ETC. PROVIDE FIXTURES WITH CHAIN SUSPENSION KITS AS REQUIRED TO SUSPEND BELOW DUCTS, IF REQUIRED.B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING".C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 1 0 V . D I M M I N G W I R I N G . GENERAL NOTES: LIGHTING 1 I N S T A L L B E H I N D F L A T P A N E L D I S P L A Y , C O O R D I N A T E LO C A T I O N A N D H E I G H T W I T H A R C H I T E C T U R A L D R A W I N G S , AN D T V M O U N T I N G B R A C K E T . 2 I N S T A L L B E H I N D F L A T P A N E L D I S P L A Y , C O O R D I N A T E LO C A T I O N A N D H E I G H T W I T H A R C H I T E C T U R A L D R A W I N G S , AN D T V M O U N T I N G B R A C K E T . P R O V I D E A N D I N S T A L L 1 . 5 " C ., FR O M J - B O X B E H I N D T V T O J - B O X O N W A L L N O R T H O F T V . 3 S L I M - L I N E A V S Y S T E M C A B I N E T . P R O V I D E ( 2 ) D U P L E X OU T L E T S I N C A B I N E T , E X T R A - D E E P B O X W I T H 1 1 / 2 " C O N D UIT TO A B O V E A C C E S S I B L E C E I L I N G F O R D A T A / A V C A B L I N G . CO O R D I N A T E E X A C T P L A C E M E N T O F B O X E S W I T H C A B I N E T AN D K E N D E N J E N S E N , C A M P U S A V , P R I O R T O R O U G H - I N . PR O V I D E A # 1 0 G R E E N I N S U L A T E D G R O U N D C O N D U C T O R FR O M C A B I N E T T O N E A R E S T E L E C T R I C A L R O O M G R O U N D BA R . F I E L D V E R I F Y F I N A L L O C A T I O N P R I O R T O R O U G H - I N . 4 E . C . S H A L L P R O V I D E A N D I N S T A L L 1 2 0 V P O W E R A N D A L L RE Q U I R E D C O N N E C T I O N T O M O T O R I Z E D R O L L E R S H A D E S AN D C O N T R O L L E R S . C O O R D I N A T E E X A C T R E Q U I R E M E N T S WI T H S H A D E S H O P D R A W I N G S P R I O R T O R O U G H I N . S E E PL A N S F O R C I R C U I T . 5 C I R C U I T L I G H T I N G I N T H I S A R E A T O E X I S T I N G P O W E R L I NK CO N T R O L L E D L I G H T I N G C I R C U I T . P R O G R A M P E R O W N E R . 6 C O N N E C T T O E X I S T I N G C I R C U I T 7 M A K E A L L R E Q U I R E D C O N N E C T I O N T O K E Y B O X . C O O R D I N A T E EX A C T R E Q U I R E M E N T S W I T H G . C . P R I O R T O R O U G H I N . 8 M O U N T D E V I C E S I N C A S E W O R K , C O O R D I N A T E W I T H CA S E W O R K S H O P D R A W I N G S P R I O R T O R O U G H I N . 9 E X I S T I N G D E V I C E T O R E M A I N , M O D I F Y T O A C C O M M O D A T E NE W C A S E W O R K . 10 N E W F I X T U R E S T O U T I L I Z E E X I S T I N G L I G H T I N G C I R C U I T IN AR E A , C O N T R O L W I T H N E W C O N T R O L S A S S H O W N . 11 U T I L I Z E E X I S T I N G C I R C U I T A N D C O N T R O L S I N A R E A F O R FI X T U R E . 12 E L E C T R I C F I R E P L A C E , C O O R D I N A T E E X A C T C O N N E C T I O N RE Q U I R E M E N T S W I T H A R C H I T E C T P R I O R T O R O U G H I N . DI S C O N N E C T F I R E P L A C E H E A T I N G E L E M E N T A N D B L O W E R PR I O R T O I N S T A L L . KE Y N O T E S : # 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:2226 03-25-22 EE100ELECTRICALPLANSMarch 25, 2022[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]BYUI MANWARING WELCOME CENTER REMODEL Bid Set 16 ' 8' 0" 16'8'0" NO R T H NORTH SC A L E : 1 / 8 " = 1 ' - 0 " 1 PO W E R P L A N SC A L E : 1 / 8 " = 1 ' - 0 " 2 LI G H T I N G P L A N A. EVEN IF SPECIFICALLY INDICATED ON THE DRAWINGS, A LL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC. WHETHER SPECIFICALLY INDICATED ON THE DRAWINGS OR NOT. GENERAL NOTES: POWER L I G H T I N G F I X T U R E S C H E D U L E TY P E D E S C R I P T I O N M O U N T I N G V O L T A G E L U M E N S CO L O R TE M P . ( K ) M F G R . C A T A L O G # N O T E S F1 2 X 2 L A Y - I N L E D , 0 - 1 0 V D I M M I N G R E C E S S E D 1 2 0 - 2 7 7 4 0 0 0 4 00 0 L I T H O N I A E P A N L - 2 X 2 - 4 0 0 0 L M - 8 0 C R I - 4 0 K - M I N 1 - n L I G H T - M VO L T F2 6 " R O U N D R E C E S S E D L E D C A N , 0 - 1 0 V DI M M I N G RE C E S S E D 1 2 0 - 2 7 7 1 5 0 0 4 0 0 0 L I T H O N I A L D N 6 - 4 0 / 1 5 - L W 6 A R - L S S -M V O L T - E Z 1 0 - n L I G H T F3 E X I T S I G N WA L L O R CE I L I N G 12 0 - 2 7 7 N / A N / A L I T H O N I A L Q M - S - W - 3 - G - 2 0 / 2 7 7 - E L N M 6 LI G H T I N G C O N T R O L ( n L I G H T ) S Y S T E M S C H E D U L E TY P E D E S C R I P T I O N M F G R . C A T A L O G # N O T E S CE I L I N G S E N S O R S nD 1 D U A L - T E C H N O L O G Y , S M A L L M O T I O N , C E I L I N G OC C U P A N C Y S E N S O R W / A U T O D I M M I N G C O N T R O L PH O T O C E L L SE N S O R S W I T C H n C M - P D T - 9 - R J B - AD C X WA L L S W I T C H E S n1 n L I G H T O N / O F F P U S H B U T T O N S E N S O R S W I T C H n P O D M 3 n2 D n L I G H T O N / O F F P U S H B U T T O N W / D I M M I N G , 2- C H A N N E L SE N S O R S W I T C H n P O D M - 2 P D X - X 3 1. P R O V I D E 0 - 1 0 V D I M M I N G C O N D U C T O R S ( G R E Y & V I O L E T ) B E T W E E N D E V I C E A N D L I G H T F I X T U R E ( S ) F O R D I M M I N G A S I N D I C A T E D O N D W G S . 2. R O U T E A S S O C I A T E D R O O M L T G C I R C U I T T H R O U G H R E L A Y FO R C O N T R O L , P R O V D E 0 - 1 0 V D I M M I N G A N D L O W V O L T A G E C ON N E C T I O N S A S IN D I C A T E D O N D R A W I N G S A N D D E T A I L S . 3. D E V I C E C O L O R S H A L L M A T C H W I R I N G D E V I C E S ; R E F E R T O S P E C I F I C A T I O N S . 4. M O U N T D E V I C E T O B O T T O M O F S T R U C T U R E . nL I G H T L I G H T I N G C O N T R O L S C H E D U L E N O T E S : nL I G H T L I G H T I N G C O N T R O L S C H E D U L E G E N E R A L N O T E S : • E . C . S H A L L B E R E S P O N S I B L E F O R P R O V I D I N G A L L L I G H T IN G C O N T R O L C O M M I S S I O N I N G / P R O G R A M M I N G O F A L L n L I G H T C O M P O N E N T S . T H E CO M M I S S I O N I N G / P R O G R A M M I N G S H A L L B E D O N E B Y A n L I G H T C E R T I F I E D T E C H N I C I A N . • E . C . S H A L L N O T I F Y O W N E R 1 - W E E K P R I O R T O C O M M I S S I O NI N G / P R O G R A M M I N G O F T H E S Y S T E M S O T H A T T H E O W N E R C A N P R O V I D E RE P R E S E N T A T I V E S D U R I N G T H E C O M M I S S I O N I N G / P R O G R A M M I N G P E R I O D . 1. R E F E R T O D R A W I N G S F O R F I X T U R E S R E Q U I R E D T O H A V E 0- 1 0 V O R S T E P - L E V E L D I M M I N G C O N T R O L . P R O V I D E F I X T U R E( S ) W I T H L E D D R I V E R ( S ) AN D R E Q U I R E D D I M M I N G / S W I T C H - L E G C O N D U C T O R S B E T W E E N SW I T C H ( E S ) A N D F I X T U R E ( S ) T O P R O V I D E C O N T R O L A S I N D IC A T E D O N DR A W I N G S . 2. F I X T U R E T O B E C O N T I N U O U S R O W M O U N T E D , L E N G T H A S IN D I C A T E D O N D R A W I N G S . P R O V I D E R E Q U I R E D A C C E S S O R I E S /C O N N E C T O R S F O R CO N T I N U O U S R O W M O U N T I N G . 3. S C B A - S T A N D A R D C O L O R B Y A R C H I T E C T / O W N E R ( C O O R D I N AT E C O L O R W I T H A R C H I T E C T / O W N E R P R I O R T O O R D E R I N G . ) 4. F I E L D A D J U S T P E N D A N T L E N G T H A S R E Q U I R E D , V E R I F Y LE N G T H W I T H C O U N T E R A S D I R E C T E D B Y A R C H I T E C T . 5. R E F E R T O A R C H I T E C T U R A L E L E V A T I O N D R A W I N G S F O R P L AC E M E N T A N D M O U N T I N G H E I G H T O F F I X T U R E S . 6. P R O V I D E A N D I N S T A L L 1 2 0 V F A C T O R Y A P P R O V E D D I M M E R S W I T C H F O R T R A C K : A C U I T Y P / N : S Y N E R G Y I S D 4 0 0 E L V 12 0 . 7. P R O V I D E A L L C O M P O N E N T S F O R C O M P L E T E I N S T A L L A T I O N , I N C L U D I N G B U T N O T L I M I T E D T O : E N D F E E D S , C O N N E C T O RS A N D E T C . 8. T H E S U F F I X " E " D E N O T E S A F I X T U R E F U R N I S H E D W I T H AN E M E R G E N C Y T R A N S F E R D E V I C E . LI G H T F I X T U R E S C H E D U L E N O T E S : • L I G H T I N G F I X T U R E S I N D I C A T E D I N S C H E D U L E A R E B A S I S O F D E S I G N , A L T E R N A T E M A N U F A C T U R E R S S H A L L B E P R E - A P PR O V E D B Y A D D E N D U M . AL T E R N A T E M A N U C A T U R E R S S H A L L S U B M I T P E R - A P P R O V A L S T O E N G I N E E R A M I N I M U M O F 1 0 D A Y S P R I O R T O P R O J E C T B I D D A T E . GE N E R A L L I G H T I N G S C H E D U L E N O T E S :