HomeMy WebLinkAboutELECTRICAL PLANS 3/11/2022 - 22-00007 - Sundance Bldg CMMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE1.0NOTES, SCHEDULES AND DETAILS DUPLEX RECEPTACLE WALL MOUNTED FIXTURECEILING MOUNTED FIXTUREFLUORESCENT FIXTURE ELECTRICAL SYMBOL SCHEDULEBRANCH CIRCUIT - HOME-RUN TO PANELBRANCH CIRCUIT - IN FLOOR OR UNDERGROUNDMECHANICAL EQUIPMENT OR DETAIL SYMBOLDRAWING NOTE (ON THE SHEET WHERE SHOWN)THERMOSTAT W/ 3/4"CONDUIT W/PULL CORD TO MECH. UNITFAN MOTOR CONNECTION POINTBRANCH CIRCUIT - CONCEALED* SEE MECHANICAL DRAWINGS FOR CONDUIT DESTINATION ANDM.C.V.I.F.A.F.F.B.F.G.NLE.C.ABOVE FINISHED FLOORBELOW FINISHED GRADEVERIFY IN FIELDNIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF LTG CIRCUIT)MECHANICAL CONTRACTORELECTRICAL CONTRACTORMOTOR CONNECTION POINTTEFTELEPHONE / DATA BOARD (GRND AS PER UTIL. CO)TIME CLOCK SWITCHT11A-1,3DOUBLE DUPLEX OUTLET (4-PLEX)JUNCTION BOXBRANCH PANELBOARDJEMERGENCY WALL LIGHT WITH 90MIN. BATTERYPHOTOELECTRIC CELL/SWITCHHVAC SYSTEM SENSOR - SEE MECHANICALESWALL BOX DIMMER SWITCH. (SWITCH TO BE COMPAT. W/LOAD SERVED)SINGLE POLE SWITCH (SEE SUBSCRIPTS)RECESSED CAN FIXTUREMAIN/DISTRIBUTION PANELBOARDTRAC LIGHT SYSTEM**PUSHBUTTON (AS INDICATED ON DRAWINGS) ROUGH-IN BOX MUD RING ORIENTATION.RECPT.SUB-SCRIPTSAC=ABOVE COUNTERGFI=GROUND-FAULTIG=ISOLATED GROUNDS=SURGE SUPPRESSIONTR=UL TAMPER RESISTANTWP=WEATHERPROOF COVER W/GFCI RECEPT.TV= RECPT. FOR TV, SEE ARCH. ELEVATION DWGS FOR MTG. HEIGHTUSB=RECEPTACLE W/USB CHARGERCR=CORD REEL (SEE DETAIL)F=FUSED DISCONNECT (FUSE PER EQUIP. NAMEPLATE)DISCONNECT SWITCH (SIZE AND TYPE AS INDICATED)B=ENCLOSED CIRCUIT BREAKERCEILING MOUNTED DUPLEX RECEPTACLE FLOORBOX - POWER ONLY (2-DUPLEX RECEPTACLES)FLOORBOX - MULTISERVICEDUAL-LEVEL SWITCHES; IN-BOARD AND OUT-BOARD LAMPS SHALL BE SWITCHED SEPARATELY. (SUBSCRIPTAPPLIES TO BOTH SWITCHES)SWITCHSUB-SCRIPTS3 = 3-WAY4 = 4-WAYF = EXHAUST FAN TIMER (INTERMATIC MODEL EI400 SERIES)T = THERMAL OVERLOAD SWITCH W/PILOT LIGHTP = 1-POLE SWITCH WITH PILOT LIGHT. (SEE SPECS)M = SWITCH SUPPLIED W/ EQUIPMENT (INSTALLED BY E.C.)WP = WEATHERPROOFEXIT SIGN, WALL OR CEILING MOUNT & DIRECTIONAL ARROWS AS INDICATED ONDRAWINGS. CONNECT TO UNSWITCHED LEG OF NEAREST LIGHTING CIRCUIT.EMERG. FIXTURE WITH EMERG. BATTERY PACK, CONNECTED TO UNSWITCHED LEGOF LIGHTING CIRCUIT.G.C.GENERAL CONTRACTORN.T.S.NOT TO SCALEV=VFD (PROVIDED BY M.C. CONNECTED AND INSTALLED BY E.C.)COMBINATION STARTER & FUSED DISCONNECT SWITCH; 2-SETS OF NO/NC CONTACTS, CONTROL XFMR, FUSEPER EQUIP. NAMEPLATECROSS LINES SHOW # OF PHASE/NEUTRAL CONDUCTORS IF MORE THAN TWO. EQUIPMENT/ISOLATEDGROUNDING CONDUCTORS ARE NOT SHOWN. PROVIDE 'GREEN' EQUIP. GROUNDING CONDUCTOR FOR ALLCIRCUITS AND ADDITIONAL ISOLATED GROUND WHERE INDICATED.FMLED 0-10V: LEVITON RENOIR II #AWSMG-7D* W/MATCHING WALL PLATE (*COLOR TO MATCH WIRING DEVICES)F#ENIGHT LIGHT FIXTURE, CONNECTED FIXTURE TO UNSWITCHED LEG OF LIGHTINGCIRCUIT.NLPSWITCH MOUNTED OCCUPANCY SENSOR, LINE VOLTAGE,W/ COVERPLATE, (COLOR TO MATCH WIRING DEVICES)P = PASSIVE INFRARED,1-POLE [WATTSTOPPER # PW-301]P2 = PASSIVE INFRARED,2-POLE [WATTSTOPPER # PW-302]D = DUAL TECHNOLOGY,1-POLE [WATTSTOPPER # DSW-100]D2 = DUAL TECHNOLOGY,2-POLE [WATTSTOPPER # DSW-200]SCEILING DATA WITH 1" ENT CONDUIT (1) CAT 6 CABLE TO MDF. TERMINATE BOTH ENDS, SEE SPECS.CEILING MOUNTED OCCUPANCY SENSORBLANK = DUAL TECH., LINE VOLTAGE [WATTSTOPPER #DT-355]L = LARGE AREA, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2205]H = HALLWAY, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2255]R = RESTROOM, DUAL TECH., LINE VOLTAGE, 2-POLE[SENSOR SWITCH #CMR-PDT-9-2P], (1) RELAY FOR LTG, (1) RELAY FOREXHAUST FAN (30 MIN. DELAY)*PROVIDE LOW VOLTAGE SENSORS WITH POWER/RELAY PACK(S) AS REQUIRED FOR OPERATION.[WATTSTOPPER #BZ-50]VOLTAGE DROP SCHEDULECONDUCTOR SIZE IS TO BE DETERMINED FROM THE FOLLOWING SCHEDULE120 VOLT, 20A. CIRCUITS#12 CONDUCTOR FOR CIRCUITS WITH A MAXIMUM LENGTH OF 136'#10 CONDUCTOR FOR CIRCUITS WITH A MAXIMUM LENGTH OF 216'#8 CONDUCTOR FOR CIRCUITS WITH A MAXIMUM LENGTH OF 343'1.ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACTLOCATION OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS.2.ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NECBEFORE INSTALLING ANY ELECTRICAL PANELS FOR CABINETS.3.INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENTIS IN PLACE, ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED.4.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS,CEILING TYPES, ETC.5.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED ON ALLELECTRICAL EQUIPMENT.6.CONFIRM EXACT LOCATIONS OF ALL TELEPHONE / DATA OUTLETS WITH OWNER PRIOR TOROUGH - IN.7.LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TODOOR FRAME AS POSSIBLE, SO AS NOT TO INTERFERE WITH ROOM CABINETS, ETC.8.SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING.9.ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR THIS WORK ANDPAY ASSOCIATED FEES.10.MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLES AND ELECTRONICBALLASTS.11.ALL BATTERY EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHEDLEG OF THE LIGHTING CIRCUIT IN THE AREA AS PER CODE.12.UNLESS SPECIFICALLY INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TOCOORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER /CONTR., EX. DENTAL, MEDICAL,KITCHEN,EQUIPMENT ETC. THE EXACT ROUGH-IN REQUIREMENTS FOR THERE EQUIPMENT.ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTR. TO BE RESPONSIBLE FORFINAL CONNECTIONS TO ALL SPECIAL EQUIPMENT.13.ALL CONDUIT /RACEWAY /CABLES, TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IFANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO DOING ANY WORK.14.E.C. SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTINGCONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARYPROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS.15.JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. ISRESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FORCIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCHCIRCUIT WIRING".16.ALL LIGHTING CONTROLS SHALL BE PROVIDED AND INSTALLED BY E.C.17.THE BRANCH CIRCUITRY SHALL BE DESIGN/BUILD BY THE E.C. INSTALLATION SHALLCONFORM TO THE DRAWINGS, SPECIFICATIONS, 2017 NEC AND GOOD ELECTRICALPRACTICES. WIRING SHALL BE INSTALLED TO MAINTAIN A MINIMUM OF 3% VOLTAGE DROP.PROJECT GENERAL NOTES: WALL ROUGH-IN FOR DATA AND CATV WITH 1" ENT CONDUIT (1) CAT 6 CABLE TO MDF. TERMINATE BOTH ENDS,SEE SPECS.Visit the site and become acquainted with conditions to be encountered.Extra funds will not be allowed due to failure to examine site and tostandard practices of the trade. All materials shall, unless otherwiseall work and pay all costs for complete and operating systems, ascontractor shall verify the exact requirements for the electric andbe of the same type, material and manufacture for ease of futurecutting and driling of structure only with prior approval of the owner. Where cutting and patching of work is necessary, use same materialsproper functioning and shall be left in first class operating condition.ducts installed by other trades. Install conduit runs exposed to viewAll materials, fixtures and equipment shall be covered or sealed uponAll equipment shall be readily accessible for maintenance and repairs.workmanship and finish to neatly match all surrounding work.4" minimum horizontally, 12" minimum from other utility lines. Minimum conduitEach piece of equipment and all of the systems shall be adjusted to insureto final completion and acceptance of the work. Such preliminary operationThe owner reserves the right to operate any systems of equipment priorSupport conduit with one-hole malleable factory made pipe straps, fastenedRaceway Installation: Separate underground conduits in a common trenchinstallation so as to provide for safety and to insure that operation andnoted, be new and in perfect condition. All material for similar uses shallDo all drilling and cutting as necessary for installation of equipment. Dodepth shall be 18". Coordinate conduit installation with pipes, steel andparallel or at right angles to structural members, walls or building lines.appearance will be maintained after subsequent construction operations.telephone services with the utility company representatives and provideThese plans have been prepared without utility company comments. TheAll workmanship shall be performed by skilled mechanics using the bestCUTTING AND PATCHING:OPERATING AND ADJUSTING:shall not be construed as an acceptance of any work.9.with screws.EXECUTION:8.directed by the governing utilities. include existing conditions in bid price.MATERIALS AND WORKMANSHIP:COORDINATION WITH UTILITIES:maintenance.7.6.Panelboards: Circuit breakers shall be 10,000 AIC minimum. All locks keyed alikeand typewritten directories. All panels shall have a minimum of 36" workingin neat, clean and usable condition. Remove all cement, paint, grease, oilall exposed fixtures, trim and equipment, and leave the entire installationUpon completion of the work, prior to final inspection, thoroughly cleanPrior to final acceptance of the project, deliver to the owner a writtenany defective work. Demonstrate continuous satisfactory operation ofTest all wire for shorts, opens, grounds, or other defects. Correctdamaged due to faulty work and materials furnished under this section.this period, including repair or replacement of the premises that may berepair or replace all such defective items promptly that may occur duringone year guarantee on all workmanship, materials and equipment and agree toSelected by owner, installed by electrical contr.17.CLEAN-UP:GUARANTEE:all electrical equipment.and other foreign substances.19.18.TEST:LIGHTING FIXTURES:DEVICE PLATES:SERVICE EQUIPMENT:clearance in front of panel. All dimensions to be field verified.16.15.14.required, including all conduits and wires indicated, including control conduitsComplete and operable systems of electrical lighting, power and receptacles.Alterations and additions including conduit, wiring, outlets, fixtures, devicesAll work and materials shall comply with all applicable codes, safety orders,detailed as specified to a more restrictive standard or higher requirement.having jurisdiction including regulations of the State Fire Marshall, unlesslaws, ordinances and regulations of governing authorities and other agenciesThe electrical drawings are essentially diagrammatic in that all provisionsAll work, material and equipment called for by notes, schedules or otherwiseindicated on the drawings shall be furnished and installed as though fullyto conform and to avoid obstructions, without additional cost to the owner.systems can not be shown. All installations shall be adjusted as necessarynecessary to conform to structural, architectural, mechanical and plumbingELECTRICAL SPECIFICATIONSCOMPLIANCE WITH CODES:INTERPRETATION OF DRAWINGS:VISITING THE SITE:set forth in these specifications.5.4.3.Connections to all A.C. equipment as indicated andand outlets.2.INTENT:and lamps. 1.All conduit shall be continuous for grounding. All grounding conductorsAs required by code and as directed by owner.pressure connectors for larger wire. All wiring shall be copper.#14 AWG unless noted. Use "Ideal Yellow" pulling compound for all pulls.Use Scotchlock connectors for all splices in #12 wire and taped boltedType THWN or THHN copper wire insulated for 600V. Smallest wire shall beCONDUCTORS:DEVICES:GROUNDING:shall be insulated green copper, sized as shown.12.13.11.CONDUIT AND WIRING METHODS:10.As required by code and as directed by owner.·All wiring methods shall be installed in accordance with the 2014 NEC.·Type NM and SER Cable is allowed in R-2 areas in accordance with local AJH andNEC.·MC cable is allowed where concealed in walls, ceilings or floors.·All surface/exposed feeders and branch circuits shall be: Conductors in Raceway.·All wiring within finished spaces shall be concealed; surface mounted raceway isprohibited.·All underground wiring shall be: Conductors in Raceway. Direct Bury cable isprohibited.TELEPHONE/DATA SYSTEMS1.1SummaryA.Includes But Not Limited To1.Furnish and install all the equipment, materials, terminations and labor necessary to provide a complete CAT6 Telephone/Data andTelevision cabling system as described in Contract Documents including, but not limited to, raceway, outlets, modular jacks, deviceplates, cables, punch down blocks, backboards, cabinets, patch panels, grounding and other miscellaneous items required for acomplete system.2.Furnish and install main service raceway as described in Contract Documents and to comply with local telephone companyrequirements.3.Refer to Drawings for conduit sizes and quantity of cables/jacks at each outlet location. 1.2WarrantyA.A Lifetime product warranty covering all components, equipment and workmanship shall be submitted in writing with systemdocumentation. The warranty period shall begin on the system's first use by the owner. Warranty shall be vendor supplied. Contractorwarranty alone is unacceptable.B.The project must be pre-registered with Manufacturer before installation has begun.2.1ComponentsA.Boxes shall be a 4 square deep box with single-gang mudring.B.Telephone and Computer Network System Cable1.23 gauge, solid annealed copper, 4-pairs. CAT62.Use plenum-rated cable in ceilings and areas used for plenum air return3.Provide Owner with patch panels, quantity as required.4.Different colors of cabling shall be used; (Yellow - Telephone, Blue - Network)5.Manufacturers:a.Superior Essexb.Alternate manufacturer with equivalent performance standard.C.Equipment Racks1.Provide a minimum of (1) 19" wall mounted rack at each comm. board location2.Provide with 20A power strip, wire management and rack mounting kits.3.Manufacturers:a.Cooper B-lineb.Alternate manufacturer with equivalent performance standard.D.Telephone Termination Blocks1.UL verified CAT6.2.66 termination with tin lead plated IDCD.Telephone & Network Patch Panels1.UL verified CAT62.110 termination with tin lead plated IDC3.19" rack mount with backboard mounting frame.4.48 Ports5.Manufacturers:a.Levitonb.Alternate manufacturer with equivalent performance standard.E.Telephone/Network Jacks & Faceplates1.Wall Jacksa.CAT6 - Color to match cable color.2.Faceplatesa.Color to be as specified by Owner.b.Provide and install Blank inserts as needed.3.Manufacturers:a.Levitonb.Alternate manufacturer with equivalent performance standard.F.Cables shall be installed in conduit from outlet to above nearest accessible ceiling space, install J-hooks above accessible ceiling space3ft on center for supporting cable. Install cable from terminal board/data rack to each telephone/network outlet.G.Terminate cables at each outlet with specified modular jack assembly.H.Terminate cables on punch down blocks or patch panels at terminal board.I.All Faceplates, patch panels and cables shall be labeled depicting location, Cables shall be labeled on both ends.J.Terminate cabling according to EIA/TIA 568B.1 Standards.K. Installation of all materials shall be as recommended by manufacturer.3.2 Quality AssuranceA.Comply with applicable portions of NEC ANSI/EIA/TIA 568 as to type products used and installation of components. Provide productsand materials which have been UL-listed and labeled.B.Cabling system shall meet the performance requirements of the ANSI/TIA/EIA-568-B Standards (Annex E).C.Each cable and patch cable shall be tested from the outlet location to the patch panel, the system shall be tested to Category 6 Level IIcompliance. The test path shall include workstation jacks, Horizontal cabling and patch panels. Contractor shall replace any equipment orcabling that fails and retest. Provide Owner with complete test reports of cabling system.TV1" ENT CONDUIT WITH (1) CAT 6 CABLE AND (1) RG6 COAX CABLE TO MDF. TERMINATE BOTH ENDS, SEE SPECS.ELEVATOR NOTES:ELEVATOR GENERAL NOTES:1.BUSSMAN ELEVATOR POWER MODULE (SEE SCHEDULE). MOUNT ADJACENTTO ELEVATOR CONTROLLER EQUIPMENT.2.30A/2P FUSED, GENERAL-DUTY SAFETY SWITCH WITH LOCKOUT CAPABILITY.DISCONNECT IS FOR ELEVATOR CAR LIGHTS, CONTROLS, OUTLETS, VENTPOWER AND ETC. FOR ELEVATOR CAR. SEE NEC 620 FOR INFORMATION.3.TELEPHONE OUTLET OR JUNCTION POINT IN EQUIPMENT RM, VERIFYLOCATION.4.3/4" CONDUIT TO MAIN TELEPHONE BOARD/CABINET IN BUILDING; SEE PLANSFOR LOCATION. PROVIDE PULL CORD OR CABLE AS SPECIFIED ONDRAWINGS.5.3/4" CONDUIT CONNECTION TO ELEVATOR CAR EMERGENCY PHONE. VERIFYCONNECTION POINT WITH EQUIPMENT.6.DEDICATED 120V CIRCUIT FOR ELEVATOR CAR LIGHTS. UTILIZE EMERG.POWER CIRCUIT WHEN AN EMERG. GENERATOR IS INSTALLED. SEE POWERPLAN FOR CIRCUIT NUMBER.7.CONNECTION TO ELEVATOR CAR LIGHTS, VERIFY EXACT CONNECTIONPOINT WITH ELEVATOR EQUIPMENT.8.PROVIDE A GFCI RECEPTACLE, LIGHT FIXTURES AND SWITCH IN ELEVATORPIT. VERIFY EXACT PLACEMENT WITH ELEVATOR INSTALLER. LOCATESWITCH AT PIT ACCESS SUCH THAT LIGHTS MAY BE SWITCHED WITHOUTENTERING PIT. LIGHT FIXTURES SHALL BE LITHONIA# DMW2-L24-3000LM-PFL-WD-MVOLT-40K-80CRI. PROVIDE (2) FIXTURES ON OPPOSITE WALLS OF PIT.MINIMUM FC IN PIT TO BE NOT LESS THAN 10FC.9.PROVIDE FIRE ALARM SYSTEM CONNECTION/MONITORING OF THE SHUNTTRIP VOLTAGE, ELEVATOR RECALL, FIREMANS HAT, AND ETC PER NFPA 72.10.PROVIDE AND INSTALL (1) SURFACE/PENDANT LIGHT FIXTURE IN CENTER OFEQUIPMENT ROOM; LITHONIA# ZL2N-L48-5000LM-MDD-MVOLT-40K-80CRI-WH-HC36 OR EQUAL. CONNECT FIXTURE TO EQUIPMENT ROOM CIRCUIT.A.CONTRACTOR SHALL OBTAIN EXACT FUSE/CIRCUIT SIZE REQUIRED BY THEELEVATOR EQUIPMENT SUPPLIER PRIOR TO ANY ROUGH-IN.B.PRIOR TO ROUGH-IN OR MOUNTING OF EQUIPMENT IN THE ELEVATOREQUIPMENT ROOM, COORDINATE WITH THE ELEVATOR EQUIPMENT SUPPLIERFOR PLACEMENT OF ALL PANELS, ETC. TO INSURE PROPER WORKINGCLEARANCES.C.ONLY EQUIPMENT ASSOCIATED TO THE ELEVATOR SHALL BE ALLOWED TO BEINSTALLED IN THE ELEV. EQUIP. ROOM WITH THE EXCEPTION OF ANY SPECIALCODE REQUIRED SYSTEMS SUCH AS FIRE ALARM.D.ALL ELECTRICAL REQUIREMENTS FOR THE ELEVATOR SHALL COMPLY WITHNEC SECTION 620.INCOMING POWER FEEDERSSEE SCHEDULE FOR SIZECONNECTION TOFIRE ALARM SYSTEMSEE NOTE #9SEENOTE #6SEENOTE #4SEENOTE #7SEENOTE #5SEENOTE #31T-3SEENOTE #2ELEVATOR POWERMODULE BY E.C.SEE NOTE #1ELEVATOR CONTROLLERBY ELEV. EQUIP. SUPPLIERVERIFY LOCATION120 VOLT CRKT.SEE SCHEDULEGFI OUTLET INEQUIP. RMLIGHT FIXTURE(S) IN EQUIP. RM(SEE NOTE #10)SWITCH120 VOLT CRKT.SEE SCHEDULEELEVATOR SCHEDULEELEV.ID.VOLTS/PHASEHPFLAPITCIRCUITEQUIP. ROOMLTG/RECPT. CIRCUITCAR LIGHTCIRCUITELEVATORCIRCUITELEVATOR FEEDERSIZEBLDG A208V/3P30HP136A3"C., 3-#250AL + #4 GRNDBLDG B208V/3P30HP136AHBHAWP/GFIOUTLETLTG. FIXTURES(TYP OF 2)SWITCHELEVATOR PIT (SEE NOTE#8)ELEVATOR EQUIPMENT ROOMBUSSMAN POWERMODULE #PS-2-T20-R1-K-G-N2-B6"3/4" C., 1#6 B.C. GRND.CONNECT TO BLDG. GROUNDSYSTEMFINISH FLOORTYPICAL CONDUITS OUT TO VOICE/DATA OUTLETS. SEE PLAN FORSIZE, ETC. (TYPICAL TOP & ORBOTTOM OF BOARD)SCALE: NONETELEPHONE / DATA TERMINAL BOARD - DETAIL4'X8'X3/4" PLYWOODPRIME & PAINT W/TWOCOATS GREY ENAMEL(INSTALL ON WALLS ASINDICATED ON PLANS)ANCHOR SECURELY TOWALL W/ CONST. ADHESIVE.DOUBLE-DUPLEXOUTLET(S) PER PLANS120V CIRCUIT PERPLANSPULL CORDUNISTRUT ANCHORINCOMING UTILITY SERVICE CONDUIT(S)WITH INSULATED BUSHING. SEE SITEPLAN FOR SIZE, QUANTITY, ETC.GROUND BAR(SQ. D #PK27GTA)TELEPHONE, DATA,TV EQUIPMENT (TYP)INSTALL INSULATEDBUSHING ON ALLCONDUIT ENDS. (TYP)UNISTRUT ANCHORPS-2-T20-R1-K-G-N2-B3"C., 3-#250AL + #4 GRNDHBHAHBHAHBHA F3SCALE: 1/16" = 1'-0"NORTH ELEVATION - ELECTRICALSCALE: 1/16" = 1'-0"WEST ELEVATION - ELECTRICALSCALE: 1/16" = 1'-0"SOUTH ELEVATION - ELECTRICALSCALE: 1/16" = 1'-0"EAST ELEVATION - ELECTRICAL32'16'0"32'16'0"32'16'0"32'16'0"F3F3F3F3F3F3F3F3F3F3F3F3F3F3F3F3F3F3F3MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE1.1BUILDING ELEVATIONS LIGHTINGEXTERIOR LIGHTING SHOWN IS FOR BIDDING PURPOSES ONLY. E.C. SHALLVERIFY TYPE AND QUANTITY WITH OWNER PRIOR TO INSTALLATION.CONTROL ALL EXTERIOR LIGHTING PHOTO-CELL ON, TIME CLOCK OFF.PROGRAM PER OWNER. HALLC109STAIRC110HALLC109HALLC109C108ENTRYC101ELEVC105EQUIPC104CLUBC102RISERC103STAIRC107TR1EHF2EH1EH2EHTT2CU3CU4CUF1EHF9F8F6F6F8F7F7F8F8F8F1(TYP)F1(TYP)F8F7F7F7F9F9F8F7F9F6F6F8F5F5F512MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE2.0BUILDING "C" FIRST FLOOR ELECTRICAL KEY NOTES1PROVIDE AND INSTALL ELEVATOR POWER, CAR LIGHT POWER AND COMMUNICATIONS AS REQUIRED.REFER TO ELEVATOR DETAIL FOR ADDITIONAL INFO.COMM. BOARD, SEE DETAIL. PROVIDE AND INSTALL A #6 GROUND WIRE FROM SERVICE GROUND.2SCALE:BUILDING "C" FIRST FLOOR - ELECTRICAL1/8" = 1' - 0"16'8'0"N16" DIA SURFACE LEDSURFACEINCLUDEDSUNSETF9915-80-CBA120/FIXTURE NOTES:LIGHT FIXTURE SCHEDULE1*1CONNECT ALL EXIT AND EMERGENCY LIGHTS TO UNSWITCHED LEG OF EMERGENCY POWER LIGHTING CIRCUIT IN AREA.LITHOINIASTAIR LIGHT WITH OCC SENSORINCLUDEDCEILINGWL4-40LEZ1-LP830-MSD7LED UTILITY STRIP LIGHTINCLUDEDLITHONIACLXL48-4000LMSEFRDL-MVOLT-GZ10-6" LED DISKSURFACEINCLUDEDHALOSMD6R-6-930-WHEXTERIOR LED WALL SCONCEWALL PER ARCH8 WATT LED A19 CLEARELK LIGHTINGELK 42284/1-CBAVANITY LIGHT,LEDINCLUDEDSUNPARKFL0354D-VT-3000KLOW LEVEL LIGHT MOUNT TO RAILHEIGHT PER ARCHWALL OR COLUMNINCLUDEDRABSLED5-CBA2THE SUFFIX "B" DENOTES A FIXTURE TO BE SUPPLIED WITH AN EMERGENCY BATTERY DRIVER. CONNECT FIXTURES TO OPERATE WITH SURROUNDING FIXTURES UNDER NORMAL OPERATING CONDITIONS.233EC SHALL COORDINATE ALL FIXTURE TYPES AND FINISHES WITH OWNER PRIOR TO ORDERING.120/120/120/120/120/120/WALL PERARCHITECTCEILINGEMERGENCY BATTERY WALLPACK UNITUNLESS NOTEDWALL @ 8'-0INCLUDEDLITHONIAELM2-LED120/277GALVANIZED30K-80CRI-GALVBCOOPERBATTERY EXIT LIGHTINCLUDEDCEILINGAPX7-GEMERGENCY BATTERY WALLPACK UNIT - EXTERIORUNLESS NOTEDWALL @ 8'-0INCLUDEDLITHONIAAFN-CBA-EXT120/277SAME AS F4 EXCEPT 2FT IN LENGTHLITHONIASURFACE LED WRAPINCLUDEDCEILINGSBL4-LP835MAIN ENTRY PENDANTAC CABLE LENGTHINCLUDEDLUMINISPR1270-L1W30R1-120-CBA-K3-SPG120/PER ARCHPOSTLITHONIARECESSED CANINCLUDEDRECESSEDLDN6-30K-15-LO6-AR-LSS-MVOLT-EZ10PARKING LOT POLE LIGHT WITH INTEGRAL30FT. POLESEE DETAILINCLUDEDLITHONIADSX1 LED P5 40KT5W MVOLT SPA PIRH208VOCCUPANCY SENSOR AND PHOTOCELLCBA SSS305G CBASEE MECHANICAL SHEETS FOR MECHANICALEQUIPMENT SIZES AND EXACT LOCATIONS.E.C. SHALL COORDINATE ALL FIXTURE TYPESWITH OWNER PRIOR TO ORDERING. HALLC206STAIRC208HALLC206MECHC207NOOKC205ELEVC204EQUIPC202STAIRC2011EHT1HP2FWH-1PRP-1CP-1PF5F5F13(TYP)F12F12F12F12SLF6F6F8F8F6F6F8F7F8F8F8F1(TYP)F1(TYP)F8F8PANEL-"HC"F7F7MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE2.1BUILDING "C" SECOND FLOOR ELECTRICALSCALE:BUILDING "C" SECOND FLOOR - ELECTRICAL1/8" = 1' - 0"16'8'0"NSEE MECHANICAL SHEETS FOR MECHANICALEQUIPMENT SIZES AND EXACT LOCATIONS. HALLC307STAIRC309HALLC307HALLC307MECHC308ELEVC305STORC303THEATERC306RISERC302STAIRC3011EH1EH1EH3FWS-1F8F6F6F8F7F8F8F8F1(TYP)F1(TYP)F8F8F6F6F8F5F5F5F5SF2F2F2F2F2F2F7F7MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE2.2BUILDING "C" THIRD FLOOR ELECTRICALSCALE:BUILDING "C" THIRD FLOOR - ELECTRICAL1/8" = 1' - 0"16'8'0"NSEE MECHANICAL SHEETS FOR MECHANICALEQUIPMENT SIZES AND EXACT LOCATIONS. HALLC408STAIRC410HALLC408MECHC409STORC407GAMEC406ELEVC405STORC403RISERC402STAIRC4011EH4FFTWH-1PPF5F5F5F5F6F6F8F8F6F6F8F7F8F8F8F1(TYP)F1(TYP)F8F8SF7F7MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE2.3BUILDING "C" FOURTH FLOOR ELECTRICALSCALE:BUILDING "C" FOURTH FLOOR - ELECTRICAL1/8" = 1' - 0"16'8'0"NSEE MECHANICAL SHEETS FOR MECHANICALEQUIPMENT SIZES AND EXACT LOCATIONS. FF1FTF2F1F1F4TVF2F1FF1F1F1F1F1F1SPLIT WIRE TOP FORDISPOSAL BOTTOM FOR DISHWASHERF1F2F2F4F2F4F1MICROWAVE1FTF1F2F2F2F1F1F1FF4F4FF1F1F1F1F1F1SPLIT WIRE TOP FORDISPOSAL BOTTOM FOR DISHWASHERTVF2MICROWAVEFF2F1F1F4MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE3.0TYPICAL UNIT FLOOR PLANS AND NOTES FIRE ALARM SYSTEM NOTE:E.C. SHALL PROVIDE AND INSTALL A COMPLETE BUILDING FIREALARM SYSTEM TO MEET NFPA 72, 2012 IFC AND ANY LOCAL CITYREQUIREMENTS. PROVIDE ALL DOCUMENTATION, DRAWINGS, CALC'SAND ETC. TO CITY FOR PERMITTING AND INSTALLATION.SPECIAL NOTESA.PROVIDE ARC-FAULT BREAKERS ON ALL NEC REQUIRED CIRCUITS.REFER TO NEC CODE SECTION 210.12B.D.EVEN IF SPECIFICALLY INDICATED ON DRAWINGS, ALL DEVICES SHOWNAT OR NEAR MILLWORK / CASEWORK, SHALL BE COORDINATED WITH THEARCHITECTURAL CASEWORK ELEVATION DWGS., TO INSURE PROPERMOUNTING HEIGHTS, ETC. ADJUST AS NECESSARY, TO POSITION DEVICESSUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS, OR BEDIRECTLY ABOVE SINKS, OR MIDWAY BETWEEN TILEWORK / WALL ORWAINSCOATING, ETC.C.PROVIDE TAMPER-PROOF TYPE RECEPTACLES IN ALL REQUIREDAREAS AS PER CODE. REFERENCE NEC CODE SECTION 406.11.PROVIDE AND INSTALL ALL REQUIRED DEVICES AND CIRCUITS REQ'DIN DWELLING UNITS AS DESCRIBED IN ART. 210 NEC.E.E.C. SHALL COORDINATE THE EXACT PLACEMENT OF ALL WALL DEVICESWITH OWNER PRIOR TO ROUGH-IN.SCALE:TYPE "B" TYPICAL UNIT PLAN - ELECTRICAL1/8" = 1' - 0"16'8'0"GENERAL LOADS1200 SQ FT X 3 VA PER SQ FTSUB-TOTAL (HVAC LOAD)HVAC LOADSAPPLICATION OF DEMAND FACTORSSERVICE SIZERECOMMENDED SERVICE SIZE IN AMPSMIN. SERVICE SIZE IN AMPS (21,740VA @ 120/208 1PH. 3W)REMAINDER (15600) @ 40%WIRING: #2cu or #1/0 Al 3-Conductor SER cableHVAC LOAD @ 100% PER NEC BREAKERFIRST 10000 @ 100%TOTAL DEMANDGENERAL LOAD PER NEC 220.82HVAC "MAGIC PAK"GENERAL LIGHTING/POWERSMALL APPLIANCE (KITCHEN) 2-CIRCUITS10,000 VA21,740 VA91 AMPS100 AMPS100A-2P====5,500 VA3,600 VA3,000 VA==25,600VASUB-TOTAL (GENERAL LOADS)RANGE LOADDRYERDISHWASHER===10,000 VA5,000 VA1,000 VA5,500 VA6,240 VA5,500 VASMALL APPLIANCE (LAUNDRY) 1-CIRCUITSSMALL APPLIANCE (BATH) 1-CIRCUITS1,500 VA=1,500 VA=LIGHTING/RECEPTS--120/208V. 1PH. 3W. SQ D QO LOAD CENTER-UNIT PANEL201--12010014"X24"X4"SEE LOAD CALCULATIONS-----FEED TOPDIMENSIONSLOADFEED BOTTOMWATTSCONDUIT SIZES.C. INT CAP/BKR.AMPSWATTSFEEDER CONDUCTOR SIZE:TOTAL LOAD/PHASEREMARKS:35374139252729333119172321LOAD NAME 7111513 9NO. 3 5WATTS 1LOCATIONMAKE/MODELCLASSCIRLOADLLAMPEABAMPELOAD/POLEMAIN LUGS ONLYMAIN BRKR. AMPSMAIN SW.BRKPOAMPSPOBRK40423638AMPS.263432302822241820LOAD NAME 816141012 4 6 2NO.CIRSURFACEFLUSHSPAREPREPARED SPACEWASHER (1)DRYER (1)302-LIGHTING/RECEPTSSPARE2012-40RANGE (1)--2-30HVAC UNIT---- FIRE ALARM SYSTEM NOTE:E.C. SHALL PROVIDE AND INSTALL A COMPLETE BUILDING FIREALARM SYSTEM TO MEET NFPA 72, 2012 IFC AND ANY LOCAL CITYREQUIREMENTS. PROVIDE ALL DOCUMENTATION, DRAWINGS, CALC'SAND ETC. TO CITY FOR PERMITTING AND INSTALLATION.SPECIAL NOTESA.PROVIDE ARC-FAULT BREAKERS ON ALL NEC REQUIRED CIRCUITS.REFER TO NEC CODE SECTION 210.12B.D.EVEN IF SPECIFICALLY INDICATED ON DRAWINGS, ALL DEVICES SHOWNAT OR NEAR MILLWORK / CASEWORK, SHALL BE COORDINATED WITH THEARCHITECTURAL CASEWORK ELEVATION DWGS., TO INSURE PROPERMOUNTING HEIGHTS, ETC. ADJUST AS NECESSARY, TO POSITION DEVICESSUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS, OR BEDIRECTLY ABOVE SINKS, OR MIDWAY BETWEEN TILEWORK / WALL ORWAINSCOATING, ETC.C.PROVIDE TAMPER-PROOF TYPE RECEPTACLES IN ALL REQUIREDAREAS AS PER CODE. REFERENCE NEC CODE SECTION 406.11.PROVIDE AND INSTALL ALL REQUIRED DEVICES AND CIRCUITS REQ'DIN DWELLING UNITS AS DESCRIBED IN ART. 210 NEC.E.E.C. SHALL COORDINATE THE EXACT PLACEMENT OF ALL WALL DEVICESWITH OWNER PRIOR TO ROUGH-IN.GENERAL LOADS1200 SQ FT X 3 VA PER SQ FTSUB-TOTAL (HVAC LOAD)HVAC LOADSAPPLICATION OF DEMAND FACTORSSERVICE SIZERECOMMENDED SERVICE SIZE IN AMPSMIN. SERVICE SIZE IN AMPS (21,740VA @ 120/208 1PH. 3W)REMAINDER (15600) @ 40%WIRING: #2cu or #1/0 Al 3-Conductor SER cableHVAC LOAD @ 100% PER NEC BREAKERFIRST 10000 @ 100%TOTAL DEMANDGENERAL LOAD PER NEC 220.82HVAC "MAGIC PAK"GENERAL LIGHTING/POWERSMALL APPLIANCE (KITCHEN) 2-CIRCUITS10,000 VA21,740 VA91 AMPS100 AMPS100A-2P====5,500 VA3,600 VA3,000 VA==25,600VASUB-TOTAL (GENERAL LOADS)RANGE LOADDRYERDISHWASHER===10,000 VA5,000 VA1,000 VA5,500 VA6,240 VA5,500 VASMALL APPLIANCE (LAUNDRY) 1-CIRCUITSSMALL APPLIANCE (BATH) 1-CIRCUITS1,500 VA=1,500 VA=LIGHTING/RECEPTS--120/208V. 1PH. 3W. SQ D QO LOAD CENTER-UNIT PANEL201--12010014"X24"X4"SEE LOAD CALCULATIONS-----FEED TOPDIMENSIONSLOADFEED BOTTOMWATTSCONDUIT SIZES.C. INT CAP/BKR.AMPSWATTSFEEDER CONDUCTOR SIZE:TOTAL LOAD/PHASEREMARKS:35374139252729333119172321LOAD NAME 7111513 9NO. 3 5WATTS 1LOCATIONMAKE/MODELCLASSCIRLOADLLAMPEABAMPELOAD/POLEMAIN LUGS ONLYMAIN BRKR. AMPSMAIN SW.BRKPOAMPSPOBRK40423638AMPS.263432302822241820LOAD NAME 816141012 4 6 2NO.CIRSURFACEFLUSHSPAREPREPARED SPACEWASHER (1)DRYER (1)302-LIGHTING/RECEPTSSPARE2012-40RANGE (1)--2-30HVAC UNIT----SCALE:TYPE "A" TYPICAL UNIT PLAN - ELECTRICAL1/8" = 1' - 0"16'8'0"(1) GFCI BREAKER(1) GFCI BREAKER MMPCONSULTANTS:TEP793FEB 20221152 BOND AVENUE - Suite A REXBURG, IDAHO 83440 VOICE (208) 359-2309 FAX (208) 359-2271WWW.JRWA.COMP.E. JOB #2209EDLREENIGNEOH A D IFOET ATE NYAPDDOT 8270SRETSIGER ANOISS E F ORP REXBURG,IDAHO SUNDANCE APARTMENTSE3.1POWER RISER DIAGRAM APARTMENT LOADSAPPLICATION OF DEMAND FACTORSSERVICE SIZERECOMMENDED SERVICE SIZE IN AMPSMIN. SERVICE SIZE IN AMPS 308,512 VA @ 120/208 3Ø 4W)BREAKER995,200 VA X .31TOTAL DEMANDGENERAL LOAD PER NEC 220.84308,512 VA308,512 VA857 AMPS1000 AMPS1000A-3P=SUB-TOTAL (APARTMENT LOADS)995,200 VA6-BED APARTMENTS: 32 UNITS x 31,100 VA=995,200 VAE.C. SHALL PROVIDE AND INSTALL HOUSEPANELS WITH BREAKERS, CIRCUITS ANDCONTROLS FOR ALL LIGHTING AND DEVICESSHOWN ON THE DRAWINGS.NO SCALEBUILDING-"C" POWER RISER DIAGRAM1000 AMP.MAIN BRKR.3Ø, 4W120/208VMMMMMMMMMMMMGROUNDPER NECAPARTMENTLOADCENTER120/208V POWERCO. TRANSFORMER100A 2P BREAKER(TYPICAL)1 1/4"C., 3-#2 + GROUND CU OR1/0 SER AL CABLEMMMMMMMMCONDUIT AND WIRE AS DIRECTEDBY POWER COMPANY38,278 AVAILABLEFAULT CURRENT23,457 AVAILABLEFAULT CURRENTMMMMMMMMPROVIDE WITH ARC ENERGYREDUCTION PER NEC 240.87.PANELPROVIDE BREAKERS AS REQUIREDTO ACCOMMODATE HOUSE (COMMONAREA) LOADSMC/TELEVATORDISCONNECTGROUNDPER NEC(2) 3"C., 4-#250AL+ GROUND3"C., 4-#250AL+ GROUND(2) 3"C., 4-#250AL+ GROUND400A 120/208V 3P BREAKERIN NEMA 3R ENCLOSURE13,333 AVAILABLEFAULT CURRENT23,457 AVAILABLEFAULT CURRENTHOUSETO BE MOUNTED AS CLOSE TO TYPICAL DEVICE MOUNTING HEIGHTS DIAGRAMNO SCALEFINISHED FLOORARCHITECTURAL PLANS AND DETAILS.DOOR JAMBS AS POSSIBLE.COORDINATE ALL DEVICES WITH18"T.V. OUTLETALL MOUNTING HEIGHTS TYPICALUNLESS NOTED OTHERWISE.ALL SWITCHES AND THERMOSTATSNOTES: THERMOSTAT ORMECHANICAL SWITCHLIGHT SWITCHCONVENIENCE OUTLETTELEPHONE / DATA OUTLETTT(OR AS NOTED)5' - 0''4' - 0''3' - 8''50 60 70 80A.COORDINATE OUTLET HEIGHTS WITHARCHITECTS MILLWORK DWGS. TOINSURE THAT OUTLETS WILL NOT FALLBEHIND CABINETS, BACKSPLASHES,OR INTERFERE WITH WAINSCOTING, ETC.(OR AS NOTED)@ MILLWORKXX"*B.D.*COORDINATE LIGHT SWITCH & OUTLETHEIGHTS WITH ARCHITECTURAL WAINS-COTING AND OR TILE WORK SO AS NOTTO FALL MIDWAY IN THESE FINISHES.*VERIFY WITH MECH.MUD RING ORIENTATION.MMMM"HC"BREAKER AIC RATING TO MEETOR EXCEED LISTED AVAILABLE FAULT CURRENT.CONDUIT TO EXTEND A MIN.SERVICE GROUNDING DETAILOF 3" ABOVE MUD SILLGRND. CLAMP & CONNECTORW/REVERSIBLE CONTACT PLATECONDUIT TO WATER1" GRND. SERVICE(20' MIN. LENGTH)#3/O BARE COPPER WIRE1" RIGID PVC CONDUITSERVICE GRND. CONDUCTOR(CONTINUOUS)TYPICAL CONCRETE FOUNDATION FOOTING2" MIN. 3" MAX.CONDUIT TO GRND ROD1" GRND SERVICEMAINFINISHED FLOORCOPPER GRND ROD5/8" x 10"1'-0FLOOR (CONTINUOUS)GRND CONDUCTORPANEL GRND LUGSBLDG. GRND TO MAINWATER MAIN