Loading...
HomeMy WebLinkAboutCONCRETE TEST - 21-00353 - Teton River Flats Community Housing - 4Plex - B7File Name: 20075FB07212021JMD A5E9ECB7-B74B-4A81-84A1-7305CF3EB2F5 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20075 Cumulative Test Load Amount: 44.0 Project Name: Teton River Flats Test Location: Interior slab for buildings B7 and D1 Client: Headwater's Construction Admixtures: Fly ash, MP 322, MA AE 90 Ticket Number: 2500 Contractor: Alpha Construction Supplier: Walters Ready Mix Mix Number: W170F TET Pour Date: 7/14/2021 Cylinder Log #: 454 Field Test Results: Set #: 1 Slump (inches): 7.2 Slump Maximum (in): 5.0 Entrained Air (%): 0.50 Entrained Air Spec. (%): Concrete Temperature (°F): 71 Ambient Temperature (°F): 58 Unit Weight (PCF): 146.59 Tested By: Y. Kabwika Date: 7/14/2021 Time Tested: 7:00 AM Picked Up By: Yannick Kabwika Date: 7/14/2021 Time: 9:15 AM Max, Min Temperature 78.8, 52.8 File Name: 20075FB07212021JMD A5E9ECB7-B74B-4A81-84A1-7305CF3EB2F5 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 7/21/2021 4.00 12.56 23,805.0 1895.30 Type 6 3,500.0 Date: 07/21/2021 Reviewed By: E. Vail Signature: