HomeMy WebLinkAboutCONCRETE TEST - 21-00353 - Teton River Flats Community Housing - 4Plex - B7File Name:
20075FB07212021JMD
A5E9ECB7-B74B-4A81-84A1-7305CF3EB2F5 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20075
Cumulative Test Load Amount:
44.0
Project Name:
Teton River Flats
Test Location:
Interior slab for buildings B7 and D1
Client:
Headwater's Construction
Admixtures:
Fly ash, MP 322, MA AE 90
Ticket Number:
2500
Contractor:
Alpha Construction
Supplier:
Walters Ready Mix
Mix Number:
W170F TET
Pour Date:
7/14/2021
Cylinder Log #:
454
Field Test Results:
Set #:
1
Slump
(inches):
7.2
Slump
Maximum
(in):
5.0
Entrained Air
(%):
0.50
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
71
Ambient
Temperature
(°F):
58
Unit Weight
(PCF):
146.59
Tested By:
Y. Kabwika
Date:
7/14/2021
Time Tested:
7:00 AM
Picked Up By:
Yannick Kabwika
Date:
7/14/2021
Time:
9:15 AM
Max, Min Temperature
78.8, 52.8
File Name:
20075FB07212021JMD
A5E9ECB7-B74B-4A81-84A1-7305CF3EB2F5 2
Initial Break Results:
Cylinder
#:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Break
Type:
Required
28 day
Strength
(psi):
A 7 7/21/2021 4.00 12.56 23,805.0 1895.30 Type 6 3,500.0
Date:
07/21/2021
Reviewed By:
E. Vail
Signature: