Corrections in the following table need to be applied before a permit can be issued
Review Report Revisions Required
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
Pg 3 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and90 mph winds (Local Conditions)
# 21-00972Solar Panels
You must how he size of the pathways, on this house the must be 3' at the ridges. Also we need more detail on the lags and flashings that you are going to use.
Report Date: 12.10.2021
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
Lie Solar Array
Roof snow load calculation(per ASCE 7-16)Design roof snow load =29 psf
Ground Snow, pg =47 psfRoof pitch 6 :12
Flat roof snow load, pf = 0.7 Ce Ct Is pg (Eq. 7.3-1)
Ce =0.9 (Table 7.3-.1)Ct =1.2 (Table 7-3.2; cold roof with solar panels)Is =1.0pf =35.5 psf
Sloped roof snow load, ps = Cs pf (Eq. 7.4-1)
Cs =0.8 (From Figure 7.4-1b, slippery surface)
ps =28.4 psf(1 psf reduction from design roof snow load)
Roof Trusses (designed according to R802.10.1)