HomeMy WebLinkAboutENGINEER LETTER REDLINED REVISIONS - 21-00972 - 643 Mill Stream St - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 643 Mill Stream St - Solar PanelsAddress : 643 Mill Stream StApplication Type : Document Filename : Li Engineering.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments Pg 3 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and90 mph winds (Local Conditions) # 21-00972Solar Panels You must how he size of the pathways, on this house the must be 3' at the ridges. Also we need more detail on the lags and flashings that you are going to use. Report Date: 12.10.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Lie Solar Array Roof snow load calculation(per ASCE 7-16)Design roof snow load =29 psf Ground Snow, pg =47 psfRoof pitch 6 :12 Flat roof snow load, pf = 0.7 Ce Ct Is pg (Eq. 7.3-1) Ce =0.9 (Table 7.3-.1)Ct =1.2 (Table 7-3.2; cold roof with solar panels)Is =1.0pf =35.5 psf Sloped roof snow load, ps = Cs pf (Eq. 7.4-1) Cs =0.8 (From Figure 7.4-1b, slippery surface) ps =28.4 psf(1 psf reduction from design roof snow load) Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)