Loading...
HomeMy WebLinkAboutPLANS - 22-00127 - Ethereal VR LLC Arcade.pdfDESCRIPTIONREVISION DATEWALL FRAMINGSHEET TITLE:S-201 PLN# 21-12-006DRAWN BY:CHK'D BY:K.R.J.C.C.PLOT DATE:2/28/2022ENGINEER: RAY MCDOUGAL, PEEIT: J.C.C 2/28/2022127 E. Main St. Suite 111Rexburg, ID 83440www.southforkdesign.com208-852-6236South Fork Design Group, LLCJAMAL TAYLOR125 VALLEY RIVER DRIVEREXBURG, IDAHOTHESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED.Copyright 2022 | Southfork Engineering | All Rights Reserved.DOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULE ID 1 2 3 4 5 QTY 1 6 18 2 1 LOCATION Exterior Interior Interior Interior Interior FIRE RATING --- --- DOOR W 5' 3' 3'-6" 4' 3'-1" HT 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" NOTES --- --- GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE: 1. EXTERIOR WALL FRAMING SHALL BE CONVENTIONAL 2x6 FRAMING @ 16" O.C. U.N.O. 2. IF LUMBER GRADING IS NOT SPECIFIED, ASSUME SPF#2 OR BETTER. 3. SEE SHEAR OR BRACE WALL PANEL SCHEDULE FOR WALL SHEATHING AND FASTENING. 4. ENSURE THAT WALLS TALLER THAN 10' HAVE BLOCKING @ PANEL EDGES AND FIRE BLOCKING. 5. ENSURE THAT INTERIOR BEARING WALLS ARE SUPPORTED IN FLOOR BY BLOCKING OR DOUBLE JOISTS. 6. ENSURE THAT COLUMNS INDICATED ON MAIN OR UPPER FLOORS ARE DIRECTLY SUPPORT BY BEAMS OR COLUMNS IN LOWER FLOORS OR SOLID BLOCKING. PROVIDE POSITIVE CONNECTIONS BETWEEN UPPER AND LOWER. 7. INSTALL ALL HANGERS, HOLD DOWNS, TIES, AND ANCHORS & CAPS AS SPECIFIED IN MANUFACTURER DOCUMENTATION. 8. ENSURE THAT WINDOWS & DOORS ARE FLASHED AND SEALED OVER AN APPROVED WALL/ROOFING MEMBRANE TO ENSURE MOISTURE PROTECTION 9. INSTALL SIDING PER MANUFACTURER REQ., INCLUDING RAIN SCREEN OR OTHER. GAME ROOM GAME ROOM GAME ROOM GAME ROOM 6666GAME ROOM GAME ROOM GAME ROOM GAME ROOM 7777GAME ROOM GAME ROOM GAME ROOM GAME ROOM 8888GAME ROOM GAME ROOM GAME ROOM GAME ROOM 9999 2 12222 233333 45 3 3 3 3 3 43333 3333ALL WALLS TO HAVEALL WALLS TO HAVEALL WALLS TO HAVEALL WALLS TO HAVE 5/8" GYPSUM BOARD5/8" GYPSUM BOARD5/8" GYPSUM BOARD5/8" GYPSUM BOARD WITH TYPE S OR WWITH TYPE S OR WWITH TYPE S OR WWITH TYPE S OR W SCREWS @ 8" O.C.SCREWS @ 8" O.C.SCREWS @ 8" O.C.SCREWS @ 8" O.C. EDGES, 12" O.C. FIELDEDGES, 12" O.C. FIELDEDGES, 12" O.C. FIELDEDGES, 12" O.C. FIELD 7'-6"7'-6"7'-6"7'-6"30'-6"30'-6"30'-6"30'-6"32'-8"32'-8"32'-8"32'-8"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"15'-8"15'-8"15'-8"15'-8" 128'128'128'128' 7'-6"7'-6"7'-6"7'-6"5'-11"5'-11"5'-11"5'-11"17'-11"17'-11"17'-11"17'-11"6'-8"6'-8"6'-8"6'-8"32'-8"32'-8"32'-8"32'-8"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"15'-8"15'-8"15'-8"15'-8"4'4'4'4'7'7'7'7'7'7'7'7'7'7'7'7'4'4'4'4'29'29'29'29'4'4'4'4'10'-6"10'-6"10'-6"10'-6"10'-6"10'-6"10'-6"10'-6"4'4'4'4'128'128'128'128' 3'-6"3'-6"3'-6"3'-6" 5'5'5'5'16'-10"16'-10"16'-10"16'-10"4'-2"4'-2"4'-2"4'-2"5'-5"5'-5"5'-5"5'-5"5'-2"5'-2"5'-2"5'-2"7'-97'-97'-97'-91/2"1/2"1/2"1/2"5'-5"5'-5"5'-5"5'-5"7'-97'-97'-97'-91/2"1/2"1/2"1/2"29'29'29'29'INSTALL 2X6 BLOCKING ININSTALL 2X6 BLOCKING ININSTALL 2X6 BLOCKING ININSTALL 2X6 BLOCKING IN EXISTING WALLS FOREXISTING WALLS FOREXISTING WALLS FOREXISTING WALLS FOR PARTITION WALL ATTACHMENTPARTITION WALL ATTACHMENTPARTITION WALL ATTACHMENTPARTITION WALL ATTACHMENT @ 4', 6' AND 8'.@ 4', 6' AND 8'.@ 4', 6' AND 8'.@ 4', 6' AND 8'. (2) LEDGER LOK SCREWS PER(2) LEDGER LOK SCREWS PER(2) LEDGER LOK SCREWS PER(2) LEDGER LOK SCREWS PER BLOCK. (TYP.)BLOCK. (TYP.)BLOCK. (TYP.)BLOCK. (TYP.) 32" DOOR HANDLE PER ADA32" DOOR HANDLE PER ADA32" DOOR HANDLE PER ADA32" DOOR HANDLE PER ADA FIRE PARTITIONFIRE PARTITIONFIRE PARTITIONFIRE PARTITION WALLS OR (1)WALLS OR (1)WALLS OR (1)WALLS OR (1) LAYER 5/8" PROPRIETARYLAYER 5/8" PROPRIETARYLAYER 5/8" PROPRIETARYLAYER 5/8" PROPRIETARY TYPE X GYPSUMTYPE X GYPSUMTYPE X GYPSUMTYPE X GYPSUM EMERGENCY EXITEMERGENCY EXITEMERGENCY EXITEMERGENCY EXIT FIRE EXTINGUISHERFIRE EXTINGUISHERFIRE EXTINGUISHERFIRE EXTINGUISHER FIRE EXTINGUISHERFIRE EXTINGUISHERFIRE EXTINGUISHERFIRE EXTINGUISHER ADAADAADAADA COMPLIANTCOMPLIANTCOMPLIANTCOMPLIANT STATIONSTATIONSTATIONSTATION EXISTINGEXISTINGEXISTINGEXISTING ADAADAADAADA COMPLIANTCOMPLIANTCOMPLIANTCOMPLIANT BATHBATHBATHBATH 2 2 2 2 MECH.MECH.MECH.MECH. OPEN SPACEOPEN SPACEOPEN SPACEOPEN SPACE LOBBYLOBBYLOBBYLOBBY EXISTINGEXISTINGEXISTINGEXISTING GAME ROOM 1GAME ROOM 1GAME ROOM 1GAME ROOM 1GAME ROOM GAME ROOM GAME ROOM GAME ROOM 2222GAME ROOM GAME ROOM GAME ROOM GAME ROOM 3333GAME ROOM GAME ROOM GAME ROOM GAME ROOM 4444GAME ROOM GAME ROOM GAME ROOM GAME ROOM 5555 ARENAARENAARENAARENA EXISTINGEXISTINGEXISTINGEXISTING BATH 1BATH 1BATH 1BATH 1 1/2" TITON XD OR1/2" TITON XD OR1/2" TITON XD OR1/2" TITON XD OR REDHEAD WEDGEREDHEAD WEDGEREDHEAD WEDGEREDHEAD WEDGE ANCHORS @ 32"ANCHORS @ 32"ANCHORS @ 32"ANCHORS @ 32" O.C. (TYP.)O.C. (TYP.)O.C. (TYP.)O.C. (TYP.) 4 MAIN LEVEL WALL FRAMINGMAIN LEVEL WALL FRAMINGMAIN LEVEL WALL FRAMINGMAIN LEVEL WALL FRAMING SCALE: SCALE: SCALE: SCALE: 3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0"