Loading...
HomeMy WebLinkAboutFLOOR LAYOUT - 21-00434 - 1268 Stone Dr - New SFRSCALE:JOB:DRAWN:DATE:SHEET:OFNOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD3660 Gateway Street, Springfield, Oregon 97477Phone: 800-347-7260 Fax: 541-679-2612PRODUCT PLACEMENT DRAWING by K & R Design, LLCStructural and dimensional checks shall be made by the architect or engineer of record toassure accuracy of product selection and capability. The purchaser is to check and approveall dimensions, quanitities, loads and details carefully. No liability is assumed by the drafting service.Roseburg Forest Products Disclaimer:This drawing document was created using information providedby others. It is the responsibility of others to insure the accuracy,content, structural capability of the materials and to obtain theapprovals necessary for the use of the products indicated.Roseburg assumes no liability for the preparation or accuracy of thedrawing document.1. Please see installation guide for installation details.2. All interior walls shown on plan are bearing.3. Interior non-bearing walls are omitted or dashed.4. Any deviations from this design may possibly alterengineering specifications.1RFP 20-0651/4"3-22-20K&R DesignforFirst FloorFraming1Teewinot ModelIdahoSunproRFPI Joist Placement PresentationRoseburg Forest ProductsEngineered Wood ProductsCode Report Index:ICC ESR-1251 I-JoistsICC ESR-1210 LVL & LVL RimCity of Los Angeles RR25439 I-joistsCity of Los Angeles RR25680 LVLCalifornia DSA PA 131 I-JoistsCalifornia DSA PA 136 LVLCalifornia DSA AC 23-1 I-JoistsPR-L259 (RFPI Joists)PR-L289 (RigidLam LVL)PR-L270 (RigidLam Studs)CCMC 13323-R (Canada) I-JoistsCCMC 13310-R (Canada) LVLWeb Stiffeners:Web stiffeners shall be used for hardwareconnections where needed. See SimpsonStrong-tie or USP Connector Manual for additionaldetails. See Roseburg Forest Products DesignGuide for additional information relating toWeb Stiffeners.Subject to review by engineerLIVE LOAD40# PSFDEAD LOAD10# PSFTOTAL LOAD50# PSFDESIGN LOADSTeewinot ModelMain floor systemJoists spaced 16" ocPlacement presentationDesign directed by 3rd partyAdjust joist placement to allow penetrations.Included span presentation shows clear spansAttached Roseburg installation guideto be used for system installation.Default loads -- verify actualDesign is for gravity floor loads. Roof& other loads/reactions are not consideredin this design.This i-joist placement diagram is to supplement the architecturaland structural drawings for this project, it is not intended toreplace those documents. Refer to all plans and details whenconstructing this project.Drafting service has created this i-joist placement diagram fromarchitectural and structural drawings supplied by others. Verify design andproduct selection with architect or engineer of record. No liability forerrors, omissions or engineering. We are not engineers and are notresponsible for the design of this project.R1R1R1R1R1R1R1R1R1R1R1R17-J47-J59-J34-J38-J17-J2J6B3B2B1Teewinot ModelSunday, March 22, 2020Main floor systemJob # RFP 20-065Joists spaced 16" ocPlan date: 1-27-20Place joists to allow penetrationsJared KillpackVerify prio rto bid & constructionPh: 307.760.3204Mark Material Width Depth Quantity Cut Length Total LengthJoistsJ1 RFPI 400 2 1/16 11 7/8 8 40' 320' J2 RFPI 400 2 1/16 11 7/8 7 38' 266' J3 RFPI 400 2 1/16 11 7/8 13 30' 390' J4 RFPI 400 2 1/16 11 7/8 7 18' 126' J5 RFPI 400 2 1/16 11 7/8 7 9' 63' J6 RFPI 400 2 1/16 11 7/8 1 4' 4' Subtotal 1169' LVLsB12-Ply 2.0E RigidLam1 3/4 9 1/2 2 10' 20' B22-Ply 2.0E RigidLam1 3/4 9 1/2 2 9' 18' Subtotal 38' B33-Ply 2.0E RigidLam1 3/4 11 7/8 3 14' 42' Subtotal 42' RIMsR1 Rimboard 1 1/8 11 7/8 1 220' 220' Subtotal 220' 4x8 - 3/4" T&G OSB 51 1630