Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLAN REDLINED REVISIONS - 21-00837 - Crispy Cone - Remodel
Author Name Author Email Author Phone No.: Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Don Allen Don.Allen@rexburg.org 208-372-2174 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Crispy Cone - RemodelAddress : 163 W Main St Suite 102Application Type : Document Filename : Crispy Cone Rexburg-Floor Plan.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments A101 Free text Cody Jones : Building Open 1 Restroom will need to meet all ADA requirements. A101 Free text Cody Jones : Building Open 1 All Construction and materials need to comply with IBC 2018. Occupant load needs to be identified and posted. Panic Hardware shall be installed as per section 1010.1.10 Seating at table, counters, and work areas need to comply withSection 1109.11 Construction on existing buildings need to comply with IEBC. Exit lighting and Exit signs need to comply # 21-00837Commercial - Remodel Report Date: 11.01.2021 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments with IBC Section 1008 and 1013. Fire Extinguisher to be installed. Seating at tables should not interfere with means of Egressand Exit travel distance. A101 Free text Alex Owens : Electrical Open 1 No electrical plans available. All wiring must be in accordancewith 2017 NEC. A101 Free text Kyle Baldwin : P&Z Open 1 Please show customer seating plan so we can determinerequired parking stalls Report Date: 11.01.2021 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) Refrigerator Freezer FreezerRefrigerator B A 35 ' - 6 " IC E CR E A M IC E CR E A M GRILL GRILL PR O O F E R MI X E R 6'-0"9'-0 1/2"30'-0" 10 ' - 0 " 9' - 0 " 13 ' - 1 1 " STORAGE RACKS KITCHEN RESTROOM UTILITY TOPPINGS DOUGH PREP ORDERING 15'-0"3'-0"7'-0"7'-0"5'-0"8'-0 1/2" 2' - 0 " 6' - 9 1 / 2 " 4' - 6 1 / 2 " 6'-0"5'-6"3'-6 1/2"7'-0"4'-0"11'-0" EX1 EX2 MENU BOARDS OFFICE 45'-6" PICKUP 8'-0" 1 2 3 4 5 http://www.cartwright-aec.com D C B A CARTWRIGHT PROJECT # DATE: APPROVED BY: CHECKED BY: DRAWN BY: 1 2 3 4 5 DATE DESCRIPTION REVISIONS # 2120 NORTH MAIN STREET LOGAN, UT 84341 T435 753.2850 F435 753.2851 ©2021 CARTWRIGHT ARCHITECTS & ENGINEERS CARTWRIGHT 9/ 2 8 / 2 0 2 1 1 2 : 0 1 : 5 7 P M A101 FLOOR PLAN 121157 09/09/21 JC PRELIMINARY CR I S P Y C O N E T I RE X B U R G , I D A H O CW CW Please show customer seating plan so we can determine required parking stalls No electrical plans available. All wiring must be in accordance with 2017 NEC. Restroom will need to meet all ADA requirements. All Construction and materials need to comply with IBC 2018. Occupant load needs to be identified and posted. Panic Hardware shall be installed as per section 1010.1.10 Seating at table, counters, and work areas need to comply with Section 1109.11 Construction on existing buildings need to comply with IEBC. Exit lighting and Exit signs need to comply with IBC Section 1008 and 1013. Fire Extinguisher to be installed. Seating at tables should not interfere with means of Egress and Exit travel distance.