HomeMy WebLinkAboutBUILDING CODE ENGINEERED REVISIONS - 21-00837 - Crispy Cone - RemodelAuthor Name Author Email Author Phone No.:
Cody Jones Cody.Jones@rexburg.org 208-372-2173
Description : Crispy Cone - RemodelAddress : 163 W Main St Suite 102Application Type : Document Filename : 11-09-2021 Crispy Cone TI Code Review - Revisions Cycle 3.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report Revisions Required
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
Pg 1 Free text Cody Jones : Building Open 1 A2 occupancy, but as per section 303.1.1 a tenant space withoccupant load of less then 50 persons shall be classified asGroup B Occupancy.
# 21-00837Commercial - Remodel
Report Date: 11.16.2021
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
Form Version: 9/18 Printed: 9 November 2021 8:19:02 AM MEMORANDUM
Page 1 of 3
MEMO
TO: Rexburg City
DATE: 11/09/2021
PROJECT: Crispy Cone Tenant Improvement
PROJECT NO.: 112081
SUBJECT: Code Analysis
NORTH LOGAN
2120 N. Main Street
North Logan, Utah
84341
T 435-753-2850
F 435-753-2851
BUILDING CODE ANALYSIS
PROJECT NAME:CRISPY CONE TENANT IMPROVEMENT
CARTWRIGHT PROJECT NUMBER:121157
NO.ITEM CODE DATA REFERENCE
1.DESCRIPTION:TENANT IMPROVEMENT IN EXISITNG WOOD FRAME BUILDING
2.PROJECT ADDRESS:
3.JURISDICTION:CITY OF REXBURG, IDAHO
4.APPLICABLE CODE:2018 INTERNATIONAL BUILDING CODE (IBC)
5.OCCUPANCY GROUP:M IBC SECTION 309
6.TYPE OF CONSTRUCTION:TYPE V-B IBC SECTION 602.5
7.FIRE SPRINKLERS:NOT PROVIDED IBC SECTION
8.ALLOWABLE FLOOR AREA:
ALLOWABLE AREA FACTOR (At):36,000 SF IBC TABLE 506.2
ACTUAL FLOOR AREA (TENANT
IMPROVEMENT):
1,500 SF
9.FIRE-RESISTANCE RATINGS OF BUILDING ELEMENTS (HOURS):
PRIMARY STRUCTURAL FRAME:0 HOURS IBC TABLE 601
BEARING WALLS - INTERIOR:0 HOURS IBC TABLE 601
NONBEARING WALLS AND 0 HOURS IBC TABLE 601
PARTITIONS - INTERIOR:0 HOURS IBC TABLE 601
10.MEANS OF EGRESS:
MAXIMUM FLOOR AREA
ALLOWANCE PER OCCUPANT:
FUNCTION OF SPACE OCCUPANT LOAD
FACTOR
IBC TABLE 1004.1.2
(SF PER OCCUPANT)
ASSEMBLY WITHOUT FIXED SEATS -
TABLES AND CHAIRS
15 NET
BUSINESS 150 GROSS
COMMERCIAL KITCHEN 200 GROSS
11/9/21
A2 occupancy, but as per section 303.1.1 a tenant space with occupant load of less
then 50 persons shall be classified as Group B Occupancy.
MEMORANDUM (continued)
PROJECT:Crispy Cone Tenant Improvement DATE: 11/09/2021
SUBJECT:Code Analysis
Form Version: 9/18 Printed: 9 November 2021 8:19:02 AM MEMORANDUM
Page 2 of 3
OCCUPANT LOAD:
DINING AREA:585 SF /15 =39 OCCUPANTS
ORDER AREA, PICKUP AREA 690 SF /150 =5 OCCUPANTS
AND RESTROOM:
PREP AREA:300 SF /200 =2 OCCUPANTS
TOTAL OCCUPANT LOAD:46 OCCUPANTS
EGRESS REQUIREMENTS -REQUIRED NUMBER OF EXITS:1 IBC TABLE 1006.2.1
EXITS PROVIDED:2
REQUIRED EXIT WIDTH: IBC SECTION 1005.3.2
46 OCCUPANTS X 0.2 INCHES PER OCCUPANT =
9.12 INCHES (32 INCHES MINIMUM CLEAR WHEN
DOOR IS OPENED 90 DEGREES)
IBC SECTION 1010.1.1
EXIT WIDTH PROVIDED:
2 SINGLE DOORS @ 32 INCHES =64 INCHES
11.PLUMBING FIXTURES
BUILDING OCCUPANT LOAD :TOTAL:46 OCCUPANTS
MALE:23
FEMALE:23
SEPARATE FACILITIES ARE NOT REQUIRED IN AN M OCCUPANCY
WITH AN OCCUPANT LOAD OF 100 OR LESS
IBC SECTION 2902.2,
EXCEPTION 3.
WATER CLOSETS (1 PER 500 OCCUPANTS):IBC TABLE 2902.1
REQUIRED:1
PROVIDED:1 WATER CLOSETS
LAVATORIES (1 PER 750 OCCUPANTS):IBC TABLE 2902.1
REQUIRED:1
PROVIDED:1
OTHER PLUMBING FIXTURES:DRINKING FOUNTAINS - 1 PER 1000:IBC TABLE 2902.1
REQUIRED:1
PROVIDED:2 (ONE "HIGH-LOW" DRINKING FOUNTAIN)
SERVICE SINK:
REQUIRED:1
PROVIDED:1