HomeMy WebLinkAboutBUILDING CODE ENGINEERED REVISED - 21-00837 - Crispy Cone - RemodelForm Version: 9/18 Printed: 9 November 2021 8:19:02 AM MEMORANDUM
Page 1 of 3
MEMO
TO: Rexburg City
DATE: 11/09/2021
PROJECT: Crispy Cone Tenant Improvement
PROJECT NO.: 112081
SUBJECT: Code Analysis
NORTH LOGAN
2120 N. Main Street
North Logan, Utah
84341
T 435-753-2850
F 435-753-2851
BUILDING CODE ANALYSIS
PROJECT NAME:CRISPY CONE TENANT IMPROVEMENT
CARTWRIGHT PROJECT NUMBER:121157
NO.ITEM CODE DATA REFERENCE
1.DESCRIPTION:TENANT IMPROVEMENT IN EXISITNG WOOD FRAME BUILDING
2.PROJECT ADDRESS:
3.JURISDICTION:CITY OF REXBURG, IDAHO
4.APPLICABLE CODE:2018 INTERNATIONAL BUILDING CODE (IBC)
5.OCCUPANCY GROUP:M IBC SECTION 309
6.TYPE OF CONSTRUCTION:TYPE V-B IBC SECTION 602.5
7.FIRE SPRINKLERS:NOT PROVIDED IBC SECTION
8.ALLOWABLE FLOOR AREA:
ALLOWABLE AREA FACTOR (At):36,000 SF IBC TABLE 506.2
ACTUAL FLOOR AREA (TENANT
IMPROVEMENT):
1,500 SF
9.FIRE-RESISTANCE RATINGS OF BUILDING ELEMENTS (HOURS):
PRIMARY STRUCTURAL FRAME:0 HOURS IBC TABLE 601
BEARING WALLS - INTERIOR:0 HOURS IBC TABLE 601
NONBEARING WALLS AND 0 HOURS IBC TABLE 601
PARTITIONS - INTERIOR:0 HOURS IBC TABLE 601
10.MEANS OF EGRESS:
MAXIMUM FLOOR AREA
ALLOWANCE PER OCCUPANT:
FUNCTION OF SPACE OCCUPANT LOAD
FACTOR
IBC TABLE 1004.1.2
(SF PER OCCUPANT)
ASSEMBLY WITHOUT FIXED SEATS -
TABLES AND CHAIRS
15 NET
BUSINESS 150 GROSS
COMMERCIAL KITCHEN 200 GROSS
11/9/21
BUILDING CODE ANALYSIS
PROJECT NAME:CRISPY CONE TENANT IMPROVEMENT
CARTWRIGHT PROJECT NUMBER:121157
NO.ITEM CODE DATA REFERENCE
1.DESCRIPTION:TENANT IMPROVEMENT IN EXISITNG WOOD FRAME BUILDING
2.PROJECT ADDRESS:
3.JURISDICTION:CITY OF REXBURG, IDAHO
4.APPLICABLE CODE:2018 INTERNATIONAL BUILDING CODE (IBC)
5.OCCUPANCY GROUP:B IBC SECTION 309
6.TYPE OF CONSTRUCTION:TYPE V-B IBC SECTION 602.5
7.FIRE SPRINKLERS:NOT PROVIDED IBC SECTION
8.ALLOWABLE FLOOR AREA:
ALLOWABLE AREA FACTOR (At):36,000 SF IBC TABLE 506.2
ACTUAL FLOOR AREA (TENANT
IMPROVEMENT):
1,500 SF
9.FIRE-RESISTANCE RATINGS OF BUILDING ELEMENTS (HOURS):
PRIMARY STRUCTURAL FRAME:0 HOURS IBC TABLE 601
BEARING WALLS - INTERIOR:0 HOURS IBC TABLE 601
NONBEARING WALLS AND 0 HOURS IBC TABLE 601
PARTITIONS - INTERIOR:0 HOURS IBC TABLE 601
10.MEANS OF EGRESS:
MAXIMUM FLOOR AREA
ALLOWANCE PER OCCUPANT:
FUNCTION OF SPACE OCCUPANT LOAD
FACTOR
IBC TABLE 1004.1.2
(SF PER OCCUPANT)
BUSINESS 150 GROSS
OCCUPANT LOAD:
ORDER AREA, PICKUP AREA 1,500 SF /150 =10 OCCUPANTS
AND RESTROOM:
TOTAL OCCUPANT LOAD:11 OCCUPANTS
EGRESS REQUIREMENTS -REQUIRED NUMBER OF EXITS:1 IBC TABLE 1006.2.1
EXITS PROVIDED:2
REQUIRED EXIT WIDTH: IBC SECTION 1005.3.2
11 OCCUPANTS X 0.2 INCHES PER OCCUPANT =
2.1 INCHES (32 INCHES MINIMUM CLEAR WHEN
DOOR IS OPENED 90 DEGREES)
IBC SECTION 1010.1.1
EXIT WIDTH PROVIDED:
2 SINGLE DOORS @ 32 INCHES =64 INCHES
MEMORANDUM (continued)
PROJECT:Crispy Cone Tenant Improvement DATE: 11/09/2021
SUBJECT:Code Analysis
Form Version: 9/18 Printed: 9 November 2021 8:19:02 AM MEMORANDUM
Page 2 of 3
OCCUPANT LOAD:
DINING AREA:585 SF /15 =39 OCCUPANTS
ORDER AREA, PICKUP AREA 690 SF /150 =5 OCCUPANTS
AND RESTROOM:
PREP AREA:300 SF /200 =2 OCCUPANTS
TOTAL OCCUPANT LOAD:46 OCCUPANTS
EGRESS REQUIREMENTS -REQUIRED NUMBER OF EXITS:1 IBC TABLE 1006.2.1
EXITS PROVIDED:2
REQUIRED EXIT WIDTH: IBC SECTION 1005.3.2
46 OCCUPANTS X 0.2 INCHES PER OCCUPANT =
9.12 INCHES (32 INCHES MINIMUM CLEAR WHEN
DOOR IS OPENED 90 DEGREES)
IBC SECTION 1010.1.1
EXIT WIDTH PROVIDED:
2 SINGLE DOORS @ 32 INCHES =64 INCHES
11.PLUMBING FIXTURES
BUILDING OCCUPANT LOAD :TOTAL:46 OCCUPANTS
MALE:23
FEMALE:23
SEPARATE FACILITIES ARE NOT REQUIRED IN AN M OCCUPANCY
WITH AN OCCUPANT LOAD OF 100 OR LESS
IBC SECTION 2902.2,
EXCEPTION 3.
WATER CLOSETS (1 PER 500 OCCUPANTS):IBC TABLE 2902.1
REQUIRED:1
PROVIDED:1 WATER CLOSETS
LAVATORIES (1 PER 750 OCCUPANTS):IBC TABLE 2902.1
REQUIRED:1
PROVIDED:1
OTHER PLUMBING FIXTURES:DRINKING FOUNTAINS - 1 PER 1000:IBC TABLE 2902.1
REQUIRED:1
PROVIDED:2 (ONE "HIGH-LOW" DRINKING FOUNTAIN)
SERVICE SINK:
REQUIRED:1
PROVIDED:1
11.PLUMBING FIXTURES
BUILDING OCCUPANT LOAD :TOTAL:11 OCCUPANTS
MALE:5
FEMALE:5
SEPARATE FACILITIES ARE NOT REQUIRED IN AN B OCCUPANCY
WITH AN OCCUPANT LOAD OF 25 OR FEWER
IBC SECTION 2902.2,
EXCEPTION 4.
WATER CLOSETS (1 PER 500 OCCUPANTS):IBC TABLE 2902.1
REQUIRED:1
PROVIDED:1 WATER CLOSETS
LAVATORIES (1 PER 750 OCCUPANTS):IBC TABLE 2902.1
REQUIRED:1
PROVIDED:1
OTHER PLUMBING FIXTURES:DRINKING FOUNTAINS - 1 PER 1000:IBC TABLE 2902.1
REQUIRED:1
PROVIDED:2 (ONE "HIGH-LOW" DRINKING FOUNTAIN)
SERVICE SINK:
REQUIRED:1
PROVIDED:1
BUILDING CODE ANALYSIS
PROJECT NAME:CRISPY CONE TENANT IMPROVEMENT
CARTWRIGHT PROJECT NUMBER:121157
NO.ITEM CODE DATA REFERENCE