HomeMy WebLinkAboutPLANS REDLINED REVISIONS - 21-00840 - 75 Aries St - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Description : 75 Aries St - Solar PanelsAddress : 75 Aries StApplication Type : Document Filename : REVA - Practical Preppers - Doug Conway - CAD_EQWqnJW04[59].pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments PV02 - SITE PLAN Free text Larry Beesley : Building Open 2 You must have the 3' pathways across the top and up the sideof the arrays fir the fire men to access the roof. PV03 - ROOFATTACHMENTS Free text Larry Beesley : Building Open 3 You must have an engineers plan or letter stating the designof the roof and if it will meet the snow and wind loads with theadded weight on the roof. This is required n al solar plans. PV05 - LINEDIAGRAM Callout Alex Owens : Electrical Open 5 Ensure this breaker is in farthest place from the main breaker.The total amount of current on the panel cannot be more than125% of panel rating as per 705.12B2(3a) PV05 - LINEDIAGRAM Callout Alex Owens : Electrical Open 5 Need proof of listing from credible testing laboratory. PV08 - PHOTOS Callout Alex Owens : Electrical Open 8 Note: PV breakers have to be normal sized breakers (no twinbreakers) # 21-00840Solar Panels Report Date: 10.28.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Rocky Mountain Power IDAHO PV SYSTEM TO BE INSTALLED BY HOMEOWNER SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 LABELS PV07 PLACARD PV08 SITE PHOTOS COVER PAGE - PV01 DRAWN BY: SoloCAD 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS AERIAL VIEW: SHEET INDEX: EQUIPMENT: AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8 kW DC (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) RACKING: SnapNrack - 48" O.C. ENERGY STORAGE: 2 ARK 48 V 100Ah LiFeP04 Batteries OCCUPANCY: R-3 ZONING: RESIDENTIAL 2017 NEC 2018 IRC 2018 IFC 2018 IBC 2018 IECC STREET VIEW: GENERAL NOTES APPLICABLE GOVERNING CODES SITE SPECIFICATIONS INV M MSP AC JB BATT BATT Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINE STRING 1: 11 MODULES STRING 2: 11 MODULES FR O N T O F H O M E 75 A r i e s D r BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER SUB SUB PANEL SITE PLAN - PV02 DRAWN BY: SoloCAD MP1 PITCH: 14° AZIMUTH: 180° 178'-2" 80'-9" 178'-2" 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 21 2 You must have the 3' pathways across the top and up the side of the arrays fir the fire men to access the roof. ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 INV M MSP AC JB BATT BATT EQUIPMENT INFORMATION: RAIL MANUFACTURER SnapNrack RAIL PART NUMBER Ultra Rail UR-40 ATTACHMENTS Quickbolt ATTACHMENT QTY 40 SPLICE QTY 6 MIDCLAMP QTY 40 ENDCLAMP QTY 8 ROOF INFO: Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:22 ARRAY AREA:MODULE COUNT * 18.06ft² = 397.32 ROOF AREA:2572 ft² PERCENT OF ROOF COVERED:15% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1100 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 27.5 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²ROOF ATTACHMENTS - PV03 DRAWN BY: SoloCAD You must have an engineers plan or letter stating the design of the roof and if it will meet the snow and wind loads with the added weight on the roof. This is required n al solar plans. RAIL L-FOOT/ATTACHMENT BRACKET (E) ROOF FRAMING QUICKBOLT FLASHING PV MODULE (E) COMP SHINGLE ROOF (1 LAYER) RAIL END CLAMP PV MODULE MID CLAMP PV MODULE 4" 2 12" MIN. DEPTH RAIL RAIL FLASHING & QUICKBOLT 2'-8" MIN - 3'-10" MAX 3 RAIL PV MODULE " MAX."1'-8" MAX. 21 FRONT VIEW 10" MIN - 1'-4" MAX 2'-8" MIN - 3'-10" MAX 10" MIN - 1'-4" MAX SIDE VIEW (E) RAFTER/TOP CHORDS (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING END CLAMP DETAILS MID CLAMP DETAILS 3 21 EQUIPMENT INFORMATION: RAIL MANUFACTURER SnapNrack RAIL PART NUMBER Ultra Rail UR-40 ATTACHMENTS Quickbolt ATTACHMENT QTY 40 SPLICE QTY 6 MIDCLAMP QTY 40 ENDCLAMP QTY 8 ROOF INFO: ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:22 ARRAY AREA:MODULE COUNT * 18.06ft² = 397.32 ROOF AREA:2572 ft² PERCENT OF ROOF COVERED:15% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1100 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 27.5 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²MOUNTING DETAIL - PV04 DRAWN BY: SoloCAD DYNAMIC DIAGRAM AC DC J-BOX 11 MODULES 11 MODULES J-BOX J-BOX 2 3 UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT 1 1 Sol-Ark-12K-P 2 STRING (2): 10.4 A DC STRING (1): 10.4 A DC N G 63A AC IN / OUT 120/240 VAC TO UTILITY GRID (E)UTILITY METER (2)ARK 48 V 100Ah LiFeP04 Battery 2/0 AWG CONDUCTORS NG (E) LOADS (E) LOADS (N) 100A CRITICAL LOADS PANEL 4 63A AC LOAD OUT 4 (E) LOADS N G (E)GROUNDING ELECTRODE INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 5. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH (N) 60A-2P (N) 225A-2P (N) 200A MAIN SERVICE PANEL 4 PV AC DISCONNECT 60A VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE DATE: October 25, 2021 REV A SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) Rocky Mountain Power IDAHO PV SYSTEM TO BE INSTALLED BY HOMEOWNER GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. SOLADECK JUNCTION BOX UL50 TYPE 3R LINE DIAGRAM - PV05 DRAWN BY: SoloCAD VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER Conduit & Conductor Schedule TAG WIRE GAUGE DESCRIPTION QTY CONDUIT SIZE CONDUCTOR RATING # OF CONDUCTORS DERATE TEMP. DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 10 AWG PV-WIRE , USE-2, COPPER (L 1, L 2)(2)N/A - FREE AIR 40A N/A - FREE AIR 0.96 38.4A N/A - FREE AIR 6 AWG BARE, COPPER (GROUND)(1) 2 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (L 1, L 2)(2)3/4" EMT 40A 1 0.96 38.4A 11.9%10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND)(1) 3 10 AWG THHN/THWN-2, COPPER - (L1, L2)(4)3/4" EMT 40A 0.8 0.96 30.72A 19.8% 10 AWG THHN/THWN-2 - (GROUND)(1) 4 6 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 32.6%10 AWG THWN-2 COPPER - (GROUND)(1) EQUIPMENT SCHEDULE: TYPE:QTY:DESCRIPTION:RATING: MODULES:(22)Canadian Solar All-Black 400w CS1Y-400 400 W INVERTERS:(1)Sol-Ark-12K-P 9000 W AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 60A ENERGY STORAGE:(2)ARK 48 V 100Ah LiFeP04 Battery 200 Ah 4 6 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 35.49%8 AWG THWN-2 COPPER - (GROUND)(1) SOLADECK JUNCTION BOX UL50 TYPE 3R SOLADECK JUNCTION BOX UL50 TYPE 3R Ensure this breaker is in farthest place from the main breaker. The total amount of current on the panel cannot be more than 125% of panel rating as per 705.12B2(3a) Need proof of listing from credible testing laboratory. Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 2 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 7 5 9 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 6 1 1 1 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 4 6 3 LABELING DIAGRAM: 8OR LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 3 4 1 LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)] 2 3 4 1 WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ! WARNING WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: ELECTRIC SHOCK HAZARD INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 40 240 WARNING: PHOTOVOLTAIC POWER SOURCE TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEMLABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS - PV06 DRAWN BY: SoloCAD INV M MSP AC JB BATT BATT Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) MAIN DISTRIBUTION UTILITY DISCONNECT AC DISCONNECT FR O N T O F H O M E INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH 75 Aries Dr, Rexburg ID 83440 BATTERY(IES) PV ARRAY PLACARD - PV07 DRAWN BY: SoloCAD Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER SITE PHOTOS: SITE PHOTOS - PV08 DRAWN BY: SoloCAD Note: PV breakers have to be normal sized breakers (no twin breakers) ALL-BLACK HIGH DENSITY MONO PERC MODULE PRODUCT CERTIFICATES* HiDM5 (All-Black) MORE POWER Maximize the light absorption area, module efficiency up to 20.1 % Low temperature coefficient (Pmax): -0.37 % / °C MORE RELIABLE CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES* 390 W ~ 405 W CS1Y-390|395|400|405MS UP TO20.1% Heavy snow load up to 5400 Pa, wind load up to 2400 Pa* Better shading tolerance Lower internal current, lower hot spot temperature As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. No. 1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 40 GW deployed around the world since 2001. *According to the applicable Canadian Solar Limited Warranty Statement. linear power output warranty* enhanced product warranty on materials and workmanship* * For detail information, please refer to Installation Manual. Minimizes micro-crack impacts Preliminary Technical Information Sheet Aesthetically pleasing design blends into your roof MECHANICAL DATA Specification Data Cell Type Mono-crystalline Dimensions 2021 ˣ 996 ˣ 35 mm (79.6 ˣ 39.2 ˣ 1.38 in) Weight 22.6 kg (49.8 lbs) Front Cover 3.0 mm tempered glass Frame Anodized aluminium alloy J-Box IP68, 3 bypass diodes Cable 4.0 mm² (IEC), 12 AWG (UL) Connector T4 series or MC4 Per Pallet 30 pieces Per Container (40' HQ)660 pieces PARTNER SECTION Rear View Frame Cross Section A-A Mounting Hole The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement. Canadian Solar Inc. reserves the right to make necessary adjustment to the information described herein at any time without further notice.Please be kindly advised that PV modules should be handled and installed by qualifiedpeople who have professional skills and please carefully read the safety and installationinstructions before using our PV modules. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com 9 14 R ELECTRICAL DATA | STC* CS1Y 390MS 395MS 400MS 405MS Nominal Max. Power (Pmax)390 W 395 W 400 W 405 W Opt. Operating Voltage (Vmp)43.1 V 43.3 V 43.5 V 43.7 V Opt. Operating Current (Imp)9.05 A 9.13 A 9.20 A 9.27 A Open Circuit Voltage (Voc)51.9 V 52.1 V 52.3 V 52.5 V Short Circuit Current (Isc)9.82 A 9.86 A 9.90 A 9.94 A Module Efficiency 19.4%19.6%19.9%20.1% Operating Temperature -40°C ~ +85°C Max. System Voltage 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 16 A Application Classification Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS1Y 390MS 395MS 400MS 405MS Nominal Max. Power (Pmax)288 W 291 W 295 W 299 W Opt. Operating Voltage (Vmp)39.7 V 39.9 V 40.1 V 40.3 V Opt. Operating Current (Imp)7.24 A 7.30 A 7.36 A 7.42 A Open Circuit Voltage (Voc)48.4 V 48.6 V 48.7 V 48.9 V Short Circuit Current (Isc)7.93 A 7.96 A 7.99 A 8.02 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. ENGINEERING DRAWING (mm)CS1Y-400MS / I-V CURVES 5°C 25°C 45°C 65°C 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 AA V 12 11 10 9 8 7 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 50 55 V 12 11 10 9 8 7 6 5 4 3 2 1 0 35 35 0 ~ + 10 W July 2020. All rights reserved, PV Module Product Datasheet V1.1_EN TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax) -0.37 % / °C Temperature Coefficient (Voc) -0.29 % / °C Temperature Coefficient (Isc) 0.05 % / °C Nominal Module Operating Temperature 44±3 °C 5 10 15 20 25 30 35 40 45 50 55 A A 115 5 35 20 2 1 996 Mounting Hole4-9x14 Grounding Hole ARK Battery Spec Sheet POWER RATINGS 100AH, 48V 200AH, 24V 200AH,48V NOMINAL VOLTAGE 48 24 48 ACTUAL VOTLAGE 20% SOC 51.2 25.6 51.2 AMP-HRS 100 200 200 CHARGING/ DISCHARGING 100AH, 48V 200AH, 24V 200AH,48V RECOMMENDED CHARGE/DISCHARGE CURRENT 75 100 100 MAX CONT. CHARGE/ DISCHARGE CURRENT 100 140 140 SURGE DISCHARGE 1 MS 200 250 250 SURGE DISCHARGE 10MS 160 210 210 RECOMMENDED ABSORB VOLTS 57.2 28.6 57.2 MAX ABSORB VOLTS- SOLAR ONLY 57.6 28.8 28.8 ABSORB DONE AMPS 5 10 10 ABSORB DONE TIME (MINUTES) 10 10 10 FLOAT VOLTS 54.4 27.2 54.4 TEMP COMP 0 0 0 ENVIRONMENT/ INSTALLATION 100AH, 48V 200AH, 24V 200AH,48V VENTILATION REQUIRED NO NO NO MINIMUM TEMP (DEGREES FARENHEIT) 32 32 32 MAXIMUM TEMP (DEGREES FARENHEIT) 120 120 120 HORIZONTAL INSTALLATION SUPPORTED YES YES YES VERTICAL INSTALLATION SUPPORTED YES YES YES SIDE & UPSIDE-DOWN INSTALLATION VOIDS WARRANTY SAFETY 100AH, 48V 200AH, 24V 200AH,48V BREAKER SIZE (AMPS) 125 160 160 BMS LOW VOLT CUTOUT 41 +/-1V 20.5 +/-1V 41 +/-1V BMS HIGH VOLT CUTOUT 60.6 +/-1V 30.3 +/-1V 60.6 +/-1V BMS LOW TEMP CUTOUT 32 F N/A N/A BMS HIGH TEMP CUTOUT 149 F 149 F 149 F PRESSURE VENTED CELLS YES YES YES INTERNAL 100AH, 48V 200AH, 24V 200AH,48V CELL CHEMISTRY LifePO4 LifePO4 LifePO4 CELL FORMAT PRISMATIC PRISMATIC PRISMATIC BMS AMP RATINGS 150 200 200 NEGATIVE SHUNT FOR SOC CALIBRATION YES YES YES BALANCING TYPE IMPACTIVE IMPACTIVE IMPACTIVE CELL CONNECTION WELDED ALUMINUM BUSBAR MAX BALANCING CURRENT 1.1A 1.1A 1.1A MIN/MAX BALANCING VOLTAGE THROUGHOUT CHARGE/ DISCHARGE CYCLE BLUETOOTH CONNECTION AND MONITORING BUILT-IN SELECTIVELY; AVAILABLE FOR TROUBLSHOOTING PURPOSES SPECS (cont.) EXTERNAL 100AH, 48V 200AH, 24V 200AH,48V NUMBER OF HANDLES ON SIDE 1 1 2 NUMBER OF HANDLES ON FRONT 2 2 2 NUMBER OF TERMINALS ON FRONT 2 2 2 NUMBER OF TERMINALS ON BACK 4 4 4 TERMINAL TYPE BOLT-ON BOLT-ON BOLT-ON TERMINAL INSULATORS INCLUDED YES YES YES FLANGE KIT FOR VERTICAL INSTALLATION INCLUDED YES YES YES LCD 100AH, 48V 200AH, 24V 200AH,48V CHARGE INDICATOR BLINKING GREEN BACKLIGHT DISCHARGE INDICATOR SOLID GREEN BACKLIGHT PROGRAMMABLE SETTINGS NO! NO! NO! CHARGE/ DISCHARGE AMPS YES YES YES BATTERY VOLTS YES YES YES CHARGE/ DISCHARGE WATTS YES YES YES STATE OF CHARGE YES YES YES TIME UNTIL FULL/ EMPTY YES YES YES AH REMAINING YES YES YES OPERATIONAL 100AH, 48V 200AH, 24V 200AH,48V RATED CYCLE LIFE 100% DOD 3,000 3,000 3,000 RATED CYCLE LIFE 80% DOD 5,000 5,000 5,000 RATED CYCLE LIFE 50% DOD 6,500 6,500 6,500 RETAINED CAPACITY AT END OF CYCLE LIFE 80% 80% 80% MAX RECOMMENDED DISCHARGE 51V (20%) 51V (20%) 51V (20%) INVERTER LOW BATTERY CUTOUT 48V 48V 48V LOW VOLT CUTOUT WAKEUP APPLY VOLTAGE >48V TO TERMINALS HIGH VOLT CUTOUT WAKEUP DISCHARGE HIGH CURRENT CUTOUT WAKEUP APPLY VOLTAGE > BATTERY VOLTAGE PRIOR TO CUTOUT CERTIFICATION 100AH, 48V 200AH, 24V 200AH,48V CELL CERTIFICATION UL1642 UL1642 UL1642 COMPLETE BATTERY CERTIFICATION UL1973 TRANSPORT CERTIFICATION UN38,3 UN38.3 UN38.3 PHYSICAL DIMENSIONS & WEIGHTS 100AH, 48V 200AH, 24V 200AH,48V PACKAGED DIMENSIONS (IN) 17 x 24 x 33 17 x 24 x 33 17x 31x 38 PACKAGED WEIGHT (LBS) 185 185 335 BATTERY DIMENSIONS (IN) 9⅛H 15¾W 23⅝L 9⅛H 15¾W 23⅝L 9⅛H 31⅛W 25⅝L BATTERY WEIGHT (LBS) 138 142 278 SnapNrack_Ultra Rail Sales Brochure_v.1.4 THESE SHEETS, DESIGNS, AND SPECS ARE PROPERTY OF SUN INCORPORATED. NO PART SHA L L B E D U P L I C A T E D O R U S E D F O R N O N E O T H E R T H A N I T S S P E C I F I C P R O J E C T W I T H O U T W R I T T E N C O N S E N T F R O M S U N I N C O R P O R A T E D . M O U N T S H E E T Sheet: 5 File: \\SUN-SERVER\Sun Incorporate d J o b s M a s t e r \ E q u i p m e n t \ M O U N T S \ Q U I C K M O U N T \ Q M P V - d a t a s h e e t - Q M H S S - L S - Q u i c k H o o k S M - w e b . p d f Missing or invalid reference S h e e t : 2 F i l e : \ \ S U N - S E R V E R \ S u n I n c o r p o r a t e d J o b s M a s t e r \ E q u i p m e n t \ M O U N T S \ Q U I C K M O U N T \ Q M P V - d a t a s h e e t - Q M H S S - L S - Q u i c k H o o k S M - w e b . p d f M i s s i n g o r i n v a l i d r e f e r e n c e