Loading...
HomeMy WebLinkAboutENGINEER LETTER - 21-00840 - 75 Aries St - Solar Panels814 E 1475 N Lehi, UT 84043 m: (309) 645-0999 Solar Professional Engineering Consulting 2021.10.13 admin@lucenteng.co Practical Preppers 834 Red Hill Rd Pickens, SC 28671 RE: Engineering Services Conway Residence 75 Aries Dr, Rexburg, ID 9 kW System Solo Job #1558723 To Whom It May Concern, A. Assumptions from Field Observation provided by Practical Preppers Roof Roof B Roof Finish :Asphalt Shingle Asphalt Shingle Roof Underlayment :Plywood Plywood Roof Profile :Gable Gable Roof Structural System :Metal Plate Trusses Metal Plate Trusses Truss Top Chord/Setup :2 x 6 / Howe 2 x 6 / Howe Chord/Rafter Wood Grade :Doug-Fir #2 or better Doug-Fir #2 or better Truss/Rafter Spacing :24'' o.c.24'' o.c. Roof Slope :10 deg 9 deg Max Top Chord/Rafter Span :6.09 ft 6.09 ft Bearing Wall Type :Convl Lt-Frame Constr CLFC Foundation :Permanent Concrete Permanent Concrete Stories :Single Single B. Building Design Criteria Code : 2018 IRC (ASCE 7-16)Risk Category : II Roof Live Load : 20 psf (0 psf at panels)Occupancy Class : R-3 Min. Roof Snow Load : 40 psf Roof Dead Load : 6.6 psf Ult Wind Speed : 115 mph PV Dead Load : 3 psf Exposure Category : C Total Dead Load : 9.6 psf C. Summary of Existing Structure Results Roof - Adaquate to support the additional imposed loads. No structural upgrades are required. The following structural design regarding the proposed alterations have been prepared from these assumptions. The verification of the field observations is the responsibility of the contractor. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the sealed plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies. After review of the field observations and based on our calculations and in accordance with the applicable building codes and current industry standards, the existing roof structure supporting the proposed alterations consisting of the solar array has been determined to be: Lucent Engineering, P.C. October 27, 2021 We have reviewed the following information regarding the solar panel installation for this project. Alterations to these documents or plans shall not be made without direct written consent of the Engineer of Record. D. Solar Panel Support Bracket Anchorage 1. 2.Manufacturer's Panel Bracket Connection to Roof Chord/Rafter Member: Fastener : (1) 5/16'' Lag Screw per Bracket NDS Withdrawl Value : 266 lbs/inch Min. Thread Length and Pentration Depth : 2.5'' 3. 4. E. Overall Summary Sincerely, John H. Leesman, PE License No. 14432 Limits of Scope of Work and Liablity Page 2 of 2 Conway Residence The existing structure is assumed to have been designed and constructed following appropriate codes at the time of erection and assumed to have appropriated permits. The calculations performed are only for the roof framing supporting the solar array installation referenced in the stamped plans and were completed according to generally recognized structural analysis standards and procedures, professional engineering, and design experience opinions and judgements. Existing deficiencies which are unknown or were not observed during the time the site observation are not included in this scope of work. All solar panel modules, racking, and mounting equipment shall be designed and installed per the manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies prior to starting construction. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. The contactor shall also verify that there are no damage/deficiencies (i.e., dry rot, water damage, termite damage, framing member/connection damage, etc.) to framing that was not addressed in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any concerns prior to starting construction. Lucent Engineering, P.C.October 27, 2021 Should you have any questions regarding this letter or if you require further information, do not hesitate to contact me. Considering the existing roof's slope, size, spacing, condition, and calculated loads, the panel bracket supports shall be placed no greater than 48 in. o/c. Panel supports connections shall be staggered to distribute load to adjacent trusses. Solar panels shall be designed, mounted, and installed in accordance with the most recent ''Ironridge Installation Manual'', which can be found on the Ironridge website (http://ironridge.com). Based on the information supplied to us at the time of this report, on the evaluation of the existing structure, and solar array panel bracket connection, it is our opinion that the roof system will adequately support the additional loads imposed by the solar array. This evaluation conforms to 2018 IRC and current industry standards. Rocky Mountain Power IDAHO PV SYSTEM TO BE INSTALLED BY HOMEOWNER SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 LABELS PV07 PLACARD PV08 SITE PHOTOS COVER PAGE - PV01 DRAWN BY: SoloCAD 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS AERIAL VIEW: SHEET INDEX: EQUIPMENT: AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8 kW DC (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) RACKING: SnapNrack - 48" O.C. ENERGY STORAGE: 2 ARK 48 V 100Ah LiFeP04 Batteries OCCUPANCY: R-3 ZONING: RESIDENTIAL 2017 NEC 2018 IRC 2018 IFC 2018 IBC 2018 IECC STREET VIEW: GENERAL NOTES APPLICABLE GOVERNING CODES SITE SPECIFICATIONS INV M MSP AC JB BATT BATT Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINE STRING 1: 11 MODULES STRING 2: 11 MODULES FR O N T O F H O M E 75 A r i e s D r BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER SUB SUB PANEL SITE PLAN - PV02 DRAWN BY: SoloCAD MP1 PITCH: 14° AZIMUTH: 180° 178'-2" 80'-9" 178'-2" 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 21 2 ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 INV M MSP AC JB BATT BATT EQUIPMENT INFORMATION: RAIL MANUFACTURER SnapNrack RAIL PART NUMBER Ultra Rail UR-40 ATTACHMENTS Quickbolt ATTACHMENT QTY 40 SPLICE QTY 6 MIDCLAMP QTY 40 ENDCLAMP QTY 8 ROOF INFO: Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:22 ARRAY AREA:MODULE COUNT * 18.06ft² = 397.32 ROOF AREA:2572 ft² PERCENT OF ROOF COVERED:15% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1100 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 27.5 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²ROOF ATTACHMENTS - PV03 DRAWN BY: SoloCAD RAIL L-FOOT/ATTACHMENT BRACKET (E) ROOF FRAMING QUICKBOLT FLASHING PV MODULE (E) COMP SHINGLE ROOF (1 LAYER) RAIL END CLAMP PV MODULE MID CLAMP PV MODULE 4" 2 12" MIN. DEPTH RAIL RAIL FLASHING & QUICKBOLT 2'-8" MIN - 3'-10" MAX 3 RAIL PV MODULE " MAX."1'-8" MAX. 21 FRONT VIEW 10" MIN - 1'-4" MAX 2'-8" MIN - 3'-10" MAX 10" MIN - 1'-4" MAX SIDE VIEW (E) RAFTER/TOP CHORDS (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING END CLAMP DETAILS MID CLAMP DETAILS 3 21 EQUIPMENT INFORMATION: RAIL MANUFACTURER SnapNrack RAIL PART NUMBER Ultra Rail UR-40 ATTACHMENTS Quickbolt ATTACHMENT QTY 40 SPLICE QTY 6 MIDCLAMP QTY 40 ENDCLAMP QTY 8 ROOF INFO: ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:22 ARRAY AREA:MODULE COUNT * 18.06ft² = 397.32 ROOF AREA:2572 ft² PERCENT OF ROOF COVERED:15% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1100 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 27.5 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²MOUNTING DETAIL - PV04 DRAWN BY: SoloCAD DYNAMIC DIAGRAM AC DC J-BOX 11 MODULES 11 MODULES J-BOX J-BOX 2 3 UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT 1 1 Sol-Ark-12K-P 2 STRING (2): 10.4 A DC STRING (1): 10.4 A DC N G 63A AC IN / OUT 120/240 VAC TO UTILITY GRID (E)UTILITY METER (2)ARK 48 V 100Ah LiFeP04 Battery 2/0 AWG CONDUCTORS NG (E) LOADS (E) LOADS (N) 100A CRITICAL LOADS PANEL 4 63A AC LOAD OUT 4 (E) LOADS N G (E)GROUNDING ELECTRODE INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 5. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH (N) 60A-2P (N) 225A-2P (N) 200A MAIN SERVICE PANEL 4 PV AC DISCONNECT 60A VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE DATE: October 25, 2021 REV A SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) Rocky Mountain Power IDAHO PV SYSTEM TO BE INSTALLED BY HOMEOWNER GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. SOLADECK JUNCTION BOX UL50 TYPE 3R LINE DIAGRAM - PV05 DRAWN BY: SoloCAD VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER Conduit & Conductor Schedule TAG WIRE GAUGE DESCRIPTION QTY CONDUIT SIZE CONDUCTOR RATING # OF CONDUCTORS DERATE TEMP. DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 10 AWG PV-WIRE , USE-2, COPPER (L 1, L 2)(2)N/A - FREE AIR 40A N/A - FREE AIR 0.96 38.4A N/A - FREE AIR 6 AWG BARE, COPPER (GROUND)(1) 2 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (L 1, L 2)(2)3/4" EMT 40A 1 0.96 38.4A 11.9%10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND)(1) 3 10 AWG THHN/THWN-2, COPPER - (L1, L2)(4)3/4" EMT 40A 0.8 0.96 30.72A 19.8% 10 AWG THHN/THWN-2 - (GROUND)(1) 4 6 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 32.6%10 AWG THWN-2 COPPER - (GROUND)(1) EQUIPMENT SCHEDULE: TYPE:QTY:DESCRIPTION:RATING: MODULES:(22)Canadian Solar All-Black 400w CS1Y-400 400 W INVERTERS:(1)Sol-Ark-12K-P 9000 W AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 60A ENERGY STORAGE:(2)ARK 48 V 100Ah LiFeP04 Battery 200 Ah 4 6 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 35.49%8 AWG THWN-2 COPPER - (GROUND)(1) SOLADECK JUNCTION BOX UL50 TYPE 3R SOLADECK JUNCTION BOX UL50 TYPE 3R Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 2 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 7 5 9 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 6 1 1 1 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 4 6 3 LABELING DIAGRAM: 8OR LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 3 4 1 LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)] 2 3 4 1 WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ! WARNING WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: ELECTRIC SHOCK HAZARD INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 40 240 WARNING: PHOTOVOLTAIC POWER SOURCE TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEMLABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS - PV06 DRAWN BY: SoloCAD INV M MSP AC JB BATT BATT Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) MAIN DISTRIBUTION UTILITY DISCONNECT AC DISCONNECT FR O N T O F H O M E INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH 75 Aries Dr, Rexburg ID 83440 BATTERY(IES) PV ARRAY PLACARD - PV07 DRAWN BY: SoloCAD Rocky Mountain Power IDAHO SITE INFORMATION Doug Conway 75 Aries Dr Rexburg, ID 83440 AC SYSTEM SIZE: 9 kW AC DC SYSTEM SIZE: 8.8 kW DC Lat, 43.8241455 Long, -111.8020256 (20) Canadian Solar All-Black 400w CS1Y-400 PV MODULES (1) Sol-Ark-12K-P INVERTER(S) DATE: October 25, 2021 REV A PV SYSTEM TO BE INSTALLED BY HOMEOWNER SITE PHOTOS: SITE PHOTOS - PV08 DRAWN BY: SoloCAD ALL-BLACK HIGH DENSITY MONO PERC MODULE PRODUCT CERTIFICATES* HiDM5 (All-Black) MORE POWER Maximize the light absorption area, module efficiency up to 20.1 % Low temperature coefficient (Pmax): -0.37 % / °C MORE RELIABLE CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES* 390 W ~ 405 W CS1Y-390|395|400|405MS UP TO20.1% Heavy snow load up to 5400 Pa, wind load up to 2400 Pa* Better shading tolerance Lower internal current, lower hot spot temperature As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. No. 1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 40 GW deployed around the world since 2001. *According to the applicable Canadian Solar Limited Warranty Statement. linear power output warranty* enhanced product warranty on materials and workmanship* * For detail information, please refer to Installation Manual. Minimizes micro-crack impacts Preliminary Technical Information Sheet Aesthetically pleasing design blends into your roof MECHANICAL DATA Specification Data Cell Type Mono-crystalline Dimensions 2021 ˣ 996 ˣ 35 mm (79.6 ˣ 39.2 ˣ 1.38 in) Weight 22.6 kg (49.8 lbs) Front Cover 3.0 mm tempered glass Frame Anodized aluminium alloy J-Box IP68, 3 bypass diodes Cable 4.0 mm² (IEC), 12 AWG (UL) Connector T4 series or MC4 Per Pallet 30 pieces Per Container (40' HQ)660 pieces PARTNER SECTION Rear View Frame Cross Section A-A Mounting Hole The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement. Canadian Solar Inc. reserves the right to make necessary adjustment to the information described herein at any time without further notice.Please be kindly advised that PV modules should be handled and installed by qualifiedpeople who have professional skills and please carefully read the safety and installationinstructions before using our PV modules. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com 9 14 R ELECTRICAL DATA | STC* CS1Y 390MS 395MS 400MS 405MS Nominal Max. Power (Pmax)390 W 395 W 400 W 405 W Opt. Operating Voltage (Vmp)43.1 V 43.3 V 43.5 V 43.7 V Opt. Operating Current (Imp)9.05 A 9.13 A 9.20 A 9.27 A Open Circuit Voltage (Voc)51.9 V 52.1 V 52.3 V 52.5 V Short Circuit Current (Isc)9.82 A 9.86 A 9.90 A 9.94 A Module Efficiency 19.4%19.6%19.9%20.1% Operating Temperature -40°C ~ +85°C Max. System Voltage 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 16 A Application Classification Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS1Y 390MS 395MS 400MS 405MS Nominal Max. Power (Pmax)288 W 291 W 295 W 299 W Opt. Operating Voltage (Vmp)39.7 V 39.9 V 40.1 V 40.3 V Opt. Operating Current (Imp)7.24 A 7.30 A 7.36 A 7.42 A Open Circuit Voltage (Voc)48.4 V 48.6 V 48.7 V 48.9 V Short Circuit Current (Isc)7.93 A 7.96 A 7.99 A 8.02 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. ENGINEERING DRAWING (mm)CS1Y-400MS / I-V CURVES 5°C 25°C 45°C 65°C 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 AA V 12 11 10 9 8 7 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 50 55 V 12 11 10 9 8 7 6 5 4 3 2 1 0 35 35 0 ~ + 10 W July 2020. All rights reserved, PV Module Product Datasheet V1.1_EN TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax) -0.37 % / °C Temperature Coefficient (Voc) -0.29 % / °C Temperature Coefficient (Isc) 0.05 % / °C Nominal Module Operating Temperature 44±3 °C 5 10 15 20 25 30 35 40 45 50 55 A A 115 5 35 20 2 1 996 Mounting Hole4-9x14 Grounding Hole ARK Battery Spec Sheet POWER RATINGS 100AH, 48V 200AH, 24V 200AH,48V NOMINAL VOLTAGE 48 24 48 ACTUAL VOTLAGE 20% SOC 51.2 25.6 51.2 AMP-HRS 100 200 200 CHARGING/ DISCHARGING 100AH, 48V 200AH, 24V 200AH,48V RECOMMENDED CHARGE/DISCHARGE CURRENT 75 100 100 MAX CONT. CHARGE/ DISCHARGE CURRENT 100 140 140 SURGE DISCHARGE 1 MS 200 250 250 SURGE DISCHARGE 10MS 160 210 210 RECOMMENDED ABSORB VOLTS 57.2 28.6 57.2 MAX ABSORB VOLTS- SOLAR ONLY 57.6 28.8 28.8 ABSORB DONE AMPS 5 10 10 ABSORB DONE TIME (MINUTES) 10 10 10 FLOAT VOLTS 54.4 27.2 54.4 TEMP COMP 0 0 0 ENVIRONMENT/ INSTALLATION 100AH, 48V 200AH, 24V 200AH,48V VENTILATION REQUIRED NO NO NO MINIMUM TEMP (DEGREES FARENHEIT) 32 32 32 MAXIMUM TEMP (DEGREES FARENHEIT) 120 120 120 HORIZONTAL INSTALLATION SUPPORTED YES YES YES VERTICAL INSTALLATION SUPPORTED YES YES YES SIDE & UPSIDE-DOWN INSTALLATION VOIDS WARRANTY SAFETY 100AH, 48V 200AH, 24V 200AH,48V BREAKER SIZE (AMPS) 125 160 160 BMS LOW VOLT CUTOUT 41 +/-1V 20.5 +/-1V 41 +/-1V BMS HIGH VOLT CUTOUT 60.6 +/-1V 30.3 +/-1V 60.6 +/-1V BMS LOW TEMP CUTOUT 32 F N/A N/A BMS HIGH TEMP CUTOUT 149 F 149 F 149 F PRESSURE VENTED CELLS YES YES YES INTERNAL 100AH, 48V 200AH, 24V 200AH,48V CELL CHEMISTRY LifePO4 LifePO4 LifePO4 CELL FORMAT PRISMATIC PRISMATIC PRISMATIC BMS AMP RATINGS 150 200 200 NEGATIVE SHUNT FOR SOC CALIBRATION YES YES YES BALANCING TYPE IMPACTIVE IMPACTIVE IMPACTIVE CELL CONNECTION WELDED ALUMINUM BUSBAR MAX BALANCING CURRENT 1.1A 1.1A 1.1A MIN/MAX BALANCING VOLTAGE THROUGHOUT CHARGE/ DISCHARGE CYCLE BLUETOOTH CONNECTION AND MONITORING BUILT-IN SELECTIVELY; AVAILABLE FOR TROUBLSHOOTING PURPOSES SPECS (cont.) EXTERNAL 100AH, 48V 200AH, 24V 200AH,48V NUMBER OF HANDLES ON SIDE 1 1 2 NUMBER OF HANDLES ON FRONT 2 2 2 NUMBER OF TERMINALS ON FRONT 2 2 2 NUMBER OF TERMINALS ON BACK 4 4 4 TERMINAL TYPE BOLT-ON BOLT-ON BOLT-ON TERMINAL INSULATORS INCLUDED YES YES YES FLANGE KIT FOR VERTICAL INSTALLATION INCLUDED YES YES YES LCD 100AH, 48V 200AH, 24V 200AH,48V CHARGE INDICATOR BLINKING GREEN BACKLIGHT DISCHARGE INDICATOR SOLID GREEN BACKLIGHT PROGRAMMABLE SETTINGS NO! NO! NO! CHARGE/ DISCHARGE AMPS YES YES YES BATTERY VOLTS YES YES YES CHARGE/ DISCHARGE WATTS YES YES YES STATE OF CHARGE YES YES YES TIME UNTIL FULL/ EMPTY YES YES YES AH REMAINING YES YES YES OPERATIONAL 100AH, 48V 200AH, 24V 200AH,48V RATED CYCLE LIFE 100% DOD 3,000 3,000 3,000 RATED CYCLE LIFE 80% DOD 5,000 5,000 5,000 RATED CYCLE LIFE 50% DOD 6,500 6,500 6,500 RETAINED CAPACITY AT END OF CYCLE LIFE 80% 80% 80% MAX RECOMMENDED DISCHARGE 51V (20%) 51V (20%) 51V (20%) INVERTER LOW BATTERY CUTOUT 48V 48V 48V LOW VOLT CUTOUT WAKEUP APPLY VOLTAGE >48V TO TERMINALS HIGH VOLT CUTOUT WAKEUP DISCHARGE HIGH CURRENT CUTOUT WAKEUP APPLY VOLTAGE > BATTERY VOLTAGE PRIOR TO CUTOUT CERTIFICATION 100AH, 48V 200AH, 24V 200AH,48V CELL CERTIFICATION UL1642 UL1642 UL1642 COMPLETE BATTERY CERTIFICATION UL1973 TRANSPORT CERTIFICATION UN38,3 UN38.3 UN38.3 PHYSICAL DIMENSIONS & WEIGHTS 100AH, 48V 200AH, 24V 200AH,48V PACKAGED DIMENSIONS (IN) 17 x 24 x 33 17 x 24 x 33 17x 31x 38 PACKAGED WEIGHT (LBS) 185 185 335 BATTERY DIMENSIONS (IN) 9⅛H 15¾W 23⅝L 9⅛H 15¾W 23⅝L 9⅛H 31⅛W 25⅝L BATTERY WEIGHT (LBS) 138 142 278 SnapNrack_Ultra Rail Sales Brochure_v.1.4 THESE SHEETS, DESIGNS, AND SPECS ARE PROPERTY OF SUN INCORPORATED. NO PART SHA L L B E D U P L I C A T E D O R U S E D F O R N O N E O T H E R T H A N I T S S P E C I F I C P R O J E C T W I T H O U T W R I T T E N C O N S E N T F R O M S U N I N C O R P O R A T E D . M O U N T S H E E T Sheet: 5 File: \\SUN-SERVER\Sun Incorporate d J o b s M a s t e r \ E q u i p m e n t \ M O U N T S \ Q U I C K M O U N T \ Q M P V - d a t a s h e e t - Q M H S S - L S - Q u i c k H o o k S M - w e b . p d f Missing or invalid reference S h e e t : 2 F i l e : \ \ S U N - S E R V E R \ S u n I n c o r p o r a t e d J o b s M a s t e r \ E q u i p m e n t \ M O U N T S \ Q U I C K M O U N T \ Q M P V - d a t a s h e e t - Q M H S S - L S - Q u i c k H o o k S M - w e b . p d f M i s s i n g o r i n v a l i d r e f e r e n c e