HomeMy WebLinkAboutRESCHECK - 22-00080 - 1053 Cypress Loop - New SFR1ZGenerated by REScheck-Web Software
Compliance Certificate
Project carmack res
Energy Code:
2018 IECC
Location:
Rexburg, Idaho
Construction Type:
Single-family
Project Type:
New Construction
Conditioned Floor Area:
1,746 ft2
Glazing Area
14%
Climate Zone:
6 (8693 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent:
tbd
rexburg, ID 83440
Designer/Contractor:
todd
surely built
Compliance: 4.5% Better Than Code Maximum UA: 335 Your UA: 320
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Ceiling: Flat Ceiling or Scissor Truss 1,746 0.0 50.0 0.019 0.026 33 45
Wall: Wood Frame, 16" ox. 2,234 23.0 0.0 0.055 0.045 108 89
Door: Solid Door (under 50% glazing) 42 0.150 0.300 6 13
Window: Vinyl Frame 222 0.300 0.300 67 67
Basement Wall: Solid Concrete or Masonry
Wall height: 9.0' 1,940 23.0 0.0 0,042 0.050 77 92
Depth below grade: 8.0'
Insulation depth: 9.0'
Window: Vinyl Frame 96 0.300 0.300 29 29
Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Title: carmack res Report date: 02/08/22
Data filename: Pagel of 9
REScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Pre-inspection/Plan Review
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
103.1,
Construction drawings and
❑Complies
103.2
documentation demonstrate
❑Does Not
[PRl]l
;energy code compliance for the
❑Not Observable
building envelope. Thermal
envelope represented on
❑Not Applicable
construction documents.
103.1,
I Construction drawings and
❑Complies
103.2,
documentation demonstrate
❑Does Not
403.7
energy code compliance for
❑Not Observable
[PR3]1
lighting and mechanical systems.
Systems serving multiple
❑Not Applicable
`
dwelling units must demonstrate
,compliance with the IECC
'Commercial
Provisions.
302.1,
Heating and cooling equipment is
Heating:
Heating: ❑Complies
403.7
sized per ACCA Manual S based
Btu/hr
Btu/hr ❑Does Not
[PR2]2
on loads calculated per ACCA
Cooling:
Cooling: [-]Not Observable
�?V
Manual J or other methods
approved by the code official.
Btu/hr
Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 2 of 9
Section
#
Foundation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
402.1.1
Conditioned basement wall R.
R- ❑Complies
see the Envelope Assemblies
[F0411
insulation R-value. Where interiorR_
R_ ❑Does Not
table for values.
j'
insulation is used, verification
❑Not Observable
may need to occur during
❑Not Applicable
Insulation Inspection. Not
,required in warm -humid locations
in Climate Zone 3.
303.2
Conditioned basement wall
❑Complies
[F05]1
'insulation installed per
FlDoes Not
manufacturer's instructions.
':❑Not Observable
❑Not Applicable
402.2.9
Conditioned basement wall ft
ft ❑Complies
5ee the Envelope Assemblies
[F06]1
insulation depth of burial or
❑Does Not
table for values.
i
distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1
A protective covering is installed
❑Complies
[FO11]2
to protect exposed exterior
❑Does Not
insulation and extends a
❑Not Observable
minimum of 6 in. below grade.
❑Not Applicable
403.9
Snow- and ice -melting system
❑Complies
[FO12]2
controls installed.
'❑Does Not
'❑Not Observable
`❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 3 of 9
Section
Sec
#
Framing / Rough -ire in�speeti®n
Plans Verified
Value
Field Verified
Value
Cornments/Assumptions
& Req.i®
I
402.1.1,
Door U-factor. U- U-
❑Complies
See the Envelope Assemblies
402.3.4
❑Does Not
tablefor values.
[FR1]1
[]Not Observable
❑Not Applicable
402.1.1,
Glazing U-factor (area -weighted U- U.
❑Complies
See the Envelope Assemblies
402.3.1,
average).
[]Does Not
table for values.
402.3.3,
[]Not Not Observable
[FR2]1
❑Not Applicable
303.1.3
'U-factors of fenestration products
❑Complies
[FR4]1
are determined in accordance
❑Does Not
with the NFRC test procedure or
❑Not Observable
-
Itaken from the default table.
❑Not Applicable
402.4.1.1
;Air barrier and thermal barrier
❑Complies
[FR23]1
:installed per manufacturer's
❑Does Not
;instructions,
❑Not Observable
❑Not Applicable
402.4.3
Fenestration that is not site built
❑Complies
[FR20]1
is listed and labeled as meeting
❑Does Not
AAMA /WDMA/CSA 1011I.S.2/A440
❑Not Observable
,or has infiltration rates per NFRC
❑Not Applicable
400 that do not exceed code
limits.
402.4.5
IC -rated recessed lighting fixtures
❑Complies
[FR16]2
sealed at housing/interior finish
❑Does Not
and labeled to indicate :52.0 cfm
❑Not Observable
.leakage at 75 Pa,
❑Not Applicable
403.3.1
Supply and return ducts in attics
❑Complies
[FR12]1
"insulated >= R-8 where duct is
[]Does Not
Q
>= 3 inches in diameter and >_
❑Not Observable
R-6 where < 3 inches. Supply and
❑Not Applicable
return ducts in other portions of
,the building insulated >= R-6 for
Idiameter >= 3 inches and R-4.2
;for < 3 inches in diameter.
403.3.2
Ducts, air handlers and filter
❑Complies
[FR1311
boxes are sealed with
❑Does Not
;joints/seams compliant with
❑Not Observable
International Mechanical Code or
❑Not Applicable
International Residential Code, as
applicable.
403.3.5
Building cavities are not used as
❑Complies
[FR15]3
ducts or plenums.
❑Does Not
❑Not Observable
❑Not Applicable
11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) 1
Project Title: carmack res Report date: 02/08/22
Data filename: Page 4 of 9
Section
#
Framing / Rough -In Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
403.3.7
Ducts declared to be within the
❑Complies
[FR28]3
conditioned space are either 1)
❑Does Not
completely within the continuous
❑Not Observable
air barrier and within the building
❑Not Applicable
thermal envelope, 2) buried
within ceiling insulation in
accordance with Section
R403.3.6 and the air handler is
located completely within the
continuous air barrier and within
the building thermal envelope
and the duct leakage is <= 1.5
cfm / 100 square feet of
conditioned floor area served by
the duct system, or 3) the ceiling
insulation R-value installed
against and above the insulated
duct >= to the proposed ceiling
insulation R-value, less the R-
value of the insulation on the
403.4
HVAC piping conveying fluids R-
R- ❑Complies
(FR1712
above 105 °F or chilled fluids
❑Does Not
below 55 4F are insulated to 2:_R-
❑Not Observable
3,
❑Not Applicable
403.4.1
Protection of insulation on HVAC
❑Complies
[FR2411
piping.
❑Does Not
❑Not Observable
❑Not Applicable
403.5.3
Hot water pipes are insulated to R-
R- ❑Complies
[FR18]2
>—R-3.
❑Does Not
❑Not Observable
❑Not Applicable
403.6
Automatic or gravity dampers are
❑Complies
[FR1912
installed on all outdoor air
❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 5 of 9
Section
#
Insulation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
303.1
All installed insulation is labeled
❑Complies
[IN13]2
or the installed R-values
❑Does Not
provided,
[]Not Observable
❑Not Applicable
402.1.1, ;
Wall insulation R-value. If this is a
' R-
R- '❑Complies
See the Envelope Assemblies
402.2.5,
mass wall with at least 1/z of the
❑ Wood
❑ Wood
❑Does Not table for values.
402.2.6
[IN3]1 4
wall insulation on the wall
exterior, the exterior insulation
Mass
❑ Mass
❑Not Observable
requirement applies (FR10).
❑ Steel
❑ Steel
[Not Applicable
303.2
Wall insulation is installed per
❑Complies
[IN4]1
manufacturer's instructions.
❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 6 of 9
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
402.1.1,
'Ceiling insulation R-value.
R-
R- ❑Complies See the Envelope Assemblies
402.2.1,
❑ Wood
❑ Wood ❑Does Not table for values.
402.2.2,
[] Steel
❑ Steel ❑Not Observable
402.2.6
[Fill'
❑Not Applicable
303.1.1.1,
Ceiling insulation installed per
❑Complies
303.2
manufacturer's instructions.
❑Does Not
[FI2]'
Blown in marked every
❑Not Observable
300 ft2.
❑Not Applicable
402.2.3
Vented attics with air permeable
❑Complies
[FI22]2
insulation include baffle adjacent
'
❑Does Not
to soffit and eave vents that
❑Not Observable
extends over insulation.
❑Not Applicable
402.2.4
(Attic access hatch and door
R-
R- '❑Complies
[FI3I1
:insulation ?R-value of the❑Does
Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2
Blower door test @ 50 Pa. <=5
ACH 50 =
ACH 50 = ❑Complies
[FI17]'
,ach in Climate Zones 1-2, and
❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
403.3.3
Ducts are pressure tested to
cfm/100
cfm/100 ❑Complies
[171271'
determine air leakage with
ft2
ft2 ❑Does Not
either: Rough -in test: Total
❑Not Observable
leakage measured with a
❑Not Applicable
pressure differential of 0.1 inch
�w.g. across the system including
:the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
'pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.4
Duct tightness test result of <=4
cfm/100
cfm/100 ❑Complies
[F1411
cfm/100 ft2 across the system or
ft2
ft2 ❑Does Not
<=3 cfm/100 ft2 without air
❑Not Observable
handler @ 25 Pa. For rough -in
❑Not Applicable
tests, verification may need to
;occur during Framing Inspection.
403.3.2.1 (Air handler leakage designated
❑Complies
[FI24]1
by manufacturer at <=2% of
❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1
Programmable thermostats
❑Complies
[17I9]2
installed for control of primary
❑Does Not
heating and cooling systems and
[]Not Observable
initially set by manufacturer to
❑Not Applicable
code specifications.
403.1.2
Heat pump thermostat installed❑Complies
[F110]2
on heat pumps.
❑Does Not
❑Not Observable
❑Not Applicable
403.5.1
'Circulating service hot water
❑Complies
[FI1112
systems have automatic or
;❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
111 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 7 of 9
I Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
403.6.1
All mechanical ventilation system
❑Complies
[F[25]2
fans not part of tested and listed
❑Does Not
HVAC equipment meet efficacy
[]Not Observable
and air flow limits per Table
❑Not Applicable
R403.6.1.
403.2
Hot water boilers supplying heat
❑Complies
[F126]2
through one- or two -pipe heating
[]Does Not
systems have outdoor setback
❑Not Observable
control to lower boiler water
❑Not Applicable
temperature based on outdoor
temperature.
403.5.1.1
Heated water circulation systems
❑Complies
[FI28]2
have a circulation pump. The
❑Does Not
system return pipe is a dedicated
❑Not Observable
return pipe or a cold water supply
❑Not Applicable
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set -point temperature and
no demand for hot water exists.
403.5.1.2
Electric heat trace systems
❑Complies
[F129]2
comply with IEEE 515.1 or UL
[]Does Not
515. Controls automatically
adjust the energy input to the
❑Not Observable
heat tracing to maintain the
❑Not Applicable
desired water temperature in the
piping.
403.5.2
Demand recirculation water
❑Complies
[F130]2
systems have controls that
❑Does Not
manage operation of the pump
[]Not Observable
and limit the temperature of the
water entering the cold water
❑Not Applicable
piping to <= 1044F.
403.5.4
_
Drain water heat recovery units
❑Complies
[FI31]2
tested in accordance with CSA
❑Does Not
B55.1. Potable water -side
pressure loss of drain water heat
❑Not Observable
recovery units < 3 psi for
❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1
90% or more of permanent
❑Complies
[FI6]1
fixtures have high efficacy lamps.
❑Does Not
❑Not Observable
❑Not Applicable
404.1.1
Fuel gas lighting systems have
❑Complies
(F123]3
no continuous pilot light.
❑Does Not
❑Not Observable
❑Not Applicable
401.3
Compliance certificate posted.
❑Complies
[F17]2
❑Does Not
❑Not Observable
❑Not Applicable
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 8 of 9
a1U%;1WNe Plans Verified Field Verified
Final Inspection ProvisionsPlains
Value
Complies? Comments/i4,ss�s�uvptioo�s
& Req.ID
303.3 Manufacturer manuals for ❑Complies
[F[18]3 :mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
[]Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: carmack res Report date: 02/08/22
Data filename: Page 9 of 9
2018 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade00
Below -Grade Wall 23.00
Floor 0.00
Ceiling / Roof 50.00
Ductwork (unconditioned spaces):
Window 0.30
Door 0.15
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments