HomeMy WebLinkAboutTRUSS SPECS - 21-00265 - 1111 Adams Ct - New SFRJob
ANDERS VARGASON - WHITW~H
Truss
A01G
Truss Type
GABLE
Qty
1
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:06 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-sIXL0TzO0U?st5sVsywNihGhSikJi8OIgLD4N?zM?sV
Scale = 1:76.7
T2 T2
B1
W5 W4
W3
W2
W1
W5
W4
W3
W2
T1 T1
B1B2
ST12
ST13
ST10
ST11
ST8
ST9ST7ST5
ST6
ST3
ST4ST2
ST1
ST12
ST13
ST10
ST11
ST8
ST9 ST7 ST5
ST6 ST3
ST4 ST2
ST1
A B
C
D
E
F
G
H
I
AB AA Z Y X W V U T S R Q P O N M L K J
5x8
5x6
5x8
3x6
5x6
3x4
3x10 5x6
3x4
3x6
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
-1-4-0
1-4-0
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
43-3-0
1-4-0
0-4-310-9-150-4-36.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8], [C:0-4-0,0-3-4], [G:0-4-0,0-3-4], [H:0-2-9,0-1-8], [O:0-3-0,0-3-0], [W:0-3-0,0-3-0], [AK:0-1-15,0-0-12], [AM:0-1-15,0-0-12], [AZ:0-1-15,0-0-12],
[BB:0-1-15,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.32
0.43
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
0.01
0.01
(loc)
B-AB
B-AB
H
B-AB
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 328 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST12: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-S, E-S, F-S
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 41-11-0.
(lb) - Max HorzB=-197(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) B, AA, AB, K, J except W=-191(LC 8),
Z=-208(LC 8), S=-209(LC 8), L=-174(LC 9), O=-179(LC 9), H=-110(LC 9)
Max Grav All reactions 250 lb or less at joint(s) T, U, V, X, Y, AA, AB, R, Q, P, N, M,
K, J except B=378(LC 19), W=527(LC 19), Z=621(LC 19), S=778(LC 1), L=610(LC
20), O=527(LC 20), H=392(LC 20), H=391(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS C-Z=-577/219, D-W=-484/170, E-S=-552/78, G-L=-568/185, F-O=-485/143
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, AA, AB, K, J except
(jt=lb) W=191, Z=208, S=209, L=174, O=179, H=110.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
A02
Truss Type
Common
Qty
3
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:08 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-ohf5R9_eY5Fa6P0t_Nzrn6L?tVM3AyVb8fiASuzM?sT
Scale = 1:70.1
T2 T2
B1
W5 W4
W3
W2 W1
W5W4
W3
W2
T1 T1
B1B2A
B
C
D
E
F
G
H
I
N M L K J
O P
5x8
5x6
5x8
3x10
5x6 1.5x4
3x4
3x10 1.5x4 5x6
3x4
3x10
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
-1-4-0
1-4-0
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
43-3-0
1-4-0
0-4-310-9-150-4-36.00 12
Plate Offsets (X,Y)-- [B:0-10-0,0-0-10], [C:0-4-0,0-3-4], [G:0-4-0,0-3-4], [H:0-10-0,0-0-10], [K:0-2-12,0-3-0], [M:0-2-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.69
0.62
0.77
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.30
-0.44
0.18
0.15
(loc)
K-L
K-L
H
L-M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 212 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-6-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-10-9 oc bracing.
WEBS 1 Row at midpt D-L, F-L
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=2168/0-5-8 (min. 0-2-5), H=2168/0-5-8 (min. 0-2-5)
Max HorzB=-197(LC 9)
Max UpliftB=-427(LC 8), H=-427(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3875/692, C-D=-3145/588, D-E=-2396/505, E-F=-2396/505, F-G=-3145/588,
G-H=-3875/692
BOT CHORD B-N=-705/3324, M-N=-706/3321, M-O=-474/2699, L-O=-474/2699, L-P=-308/2699,
K-P=-308/2699, J-K=-509/3321, H-J=-508/3324
WEBS C-M=-715/261, D-M=-59/435, D-L=-993/354, E-L=-278/1478, G-K=-715/261, F-K=-59/435,
F-L=-993/354
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=427,
H=427.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
A03
Truss Type
COMMON
Qty
10
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:09 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-GtDTeV?GJPNRkZb4X4U4JJu8wvfdvOTkMJSk_KzM?sS
Scale = 1:69.5
T2 T2
B1
W5 W4
W3
W2 W1
W5W4
W3
W2
T1 T3
B1B2A
B
C
D
E
F
G
H
M L K J I
N O
5x8
5x6
5x8
3x10
5x6 1.5x4
3x4
3x10 1.5x4 5x6
3x4
3x10
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
-1-4-0
1-4-0
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
0-4-310-9-150-4-36.00 12
Plate Offsets (X,Y)-- [B:0-10-0,0-0-10], [C:0-4-0,0-3-4], [G:0-4-0,0-3-4], [H:0-10-0,0-0-10], [J:0-2-12,0-3-4], [L:0-2-12,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.80
0.73
0.86
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.31
-0.45
0.19
0.15
(loc)
J-K
J-K
H
K-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 210 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-9-10 oc bracing.
WEBS 1 Row at midpt D-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=2179/0-5-8 (min. 0-2-5), H=2037/Mechanical
Max HorzB=208(LC 12)
Max UpliftB=-428(LC 8), H=-385(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3898/694, C-D=-3168/591, D-E=-2420/510, E-F=-2419/508, F-G=-3193/600,
G-H=-3984/720
BOT CHORD B-M=-719/3345, L-M=-720/3342, L-N=-488/2721, K-N=-488/2721, K-O=-325/2741,
J-O=-325/2741, I-J=-561/3438, H-I=-560/3441
WEBS C-L=-715/261, D-L=-58/435, D-K=-993/354, E-K=-283/1499, G-I=0/255, G-J=-792/283,
F-J=-67/461, F-K=-1017/361
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=428,
H=385.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
A03A
Truss Type
COMMON
Qty
1
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:10 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-k3nrrr0u4jVIMjAG5o?JsXQKQJ0HesYubzBHWmzM?sR
Scale = 1:69.5
T2 T2
B1
W5 W4
W3
W2 W1
W5W4
W3
W2
T1 T3
B1B2A
B
C
D
E
F
G
H
M L K J I
N O
5x8
5x6
5x8
3x10
5x6 1.5x4
3x4
3x10 1.5x4 5x6
3x4
3x10
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
-1-4-0
1-4-0
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
0-4-310-9-150-4-36.00 12
Plate Offsets (X,Y)-- [B:0-10-0,0-0-10], [C:0-4-0,0-3-4], [G:0-4-0,0-3-4], [H:0-10-0,0-0-10], [J:0-2-12,0-3-4], [L:0-2-12,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.75
0.70
0.80
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.30
-0.44
0.19
0.15
(loc)
J-K
J-K
H
K-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 210 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-9-12 oc bracing.
WEBS 1 Row at midpt D-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=2171/0-5-8 (min. 0-2-5), H=2029/0-5-8 (min. 0-2-3)
Max HorzB=208(LC 12)
Max UpliftB=-427(LC 8), H=-382(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3881/692, C-D=-3151/589, D-E=-2402/507, E-F=-2402/505, F-G=-3157/593,
G-H=-3909/705
BOT CHORD B-M=-717/3329, L-M=-718/3326, L-N=-486/2705, K-N=-486/2705, K-O=-321/2709,
J-O=-321/2709, I-J=-545/3355, H-I=-544/3358
WEBS C-L=-715/261, D-L=-58/435, D-K=-993/354, E-K=-280/1483, G-I=0/251, G-J=-743/272,
F-J=-62/442, F-K=-999/357
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=427,
H=382.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
A04G
Truss Type
GABLE
Qty
1
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:12 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-gSucGX19cKl?b0KeDD1nxyWjz6mb6suB3HgObfzM?sP
Scale = 1:71.0
T2 T2
B1
W5 W4
W3
W2
W1
W5
W4
W3
W2
T1 T3
B1B2
ST12
ST13
ST10
ST11
ST8
ST9ST7ST5
ST6
ST3
ST4ST2
ST1
ST12
ST13
ST10
ST11
ST8
ST9 ST7 ST5
ST6
ST3
ST4 ST2
ST1
A
B
C
D
E
F
G
H
AA Z Y X W V U T S R Q P O N M L K J I
5x8
5x6
5x8
4x6
5x6
3x4
3x10
5x6
3x4
4x6
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
-1-4-0
1-4-0
6-11-13
6-11-13
13-11-11
6-11-13
20-11-8
6-11-13
27-11-5
6-11-13
34-11-3
6-11-13
41-11-0
6-11-13
0-4-310-9-150-4-36.00 12
Plate Offsets (X,Y)-- [B:0-0-12,Edge], [C:0-4-0,0-3-4], [G:0-4-0,0-3-4], [H:0-0-12,Edge], [N:0-3-0,0-3-0], [V:0-3-0,0-3-0], [AJ:0-1-15,0-0-12], [AL:0-1-15,0-0-12], [AY:0-1-15,0-0-12],
[BA:0-1-15,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.39
0.43
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.02
-0.02
0.01
0.01
(loc)
H-I
H-I
H
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 326 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST12: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-R, E-R, F-R
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 41-11-0.
(lb) - Max HorzB=208(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) B, H, Z, AA, J, I except V=-192(LC 8),
Y=-210(LC 8), R=-209(LC 8), K=-182(LC 9), N=-180(LC 9)
Max Grav All reactions 250 lb or less at joint(s) H, H, S, T, U, W, X, Z, AA, Q, P, O,
M, L, J, I except B=378(LC 19), V=527(LC 19), Y=621(LC 19), R=778(LC 1),
K=619(LC 20), N=527(LC 20)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS C-Y=-577/221, D-V=-484/172, E-R=-553/80, G-K=-573/191, F-N=-484/146
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, Z, AA, J, I except
(jt=lb) V=192, Y=210, R=209, K=182, N=180.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
B01G
Truss Type
Common Supported Gable
Qty
1
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:13 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-8eS_Ut2nNetsDAvrmwY0U92?UWCVrOgKHxQx75zM?sO
Scale = 1:37.7
T1 T1
B1
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
ST1
B1
A
B
C
D
E
F
G
H
I
J
K
L
M
V U T S R Q P O N
4x4
3x4
5x6
3x4
21-1-0
21-1-0
-1-4-0
1-4-0
10-6-8
10-6-8
21-1-0
10-6-8
22-5-0
1-4-0
0-4-35-7-70-4-36.00 12
Plate Offsets (X,Y)-- [R:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.12
0.03
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.01
-0.01
0.00
(loc)
M
M
L
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 100 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-1-0.
(lb) - Max HorzB=-105(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) B, S, T, U, V, Q, P, O, N, L
Max Grav All reactions 250 lb or less at joint(s) R, S, T, U, V, Q, P, O, N except B=268(LC 1), L=268(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, S, T, U, V, Q, P, O,
N, L.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
B02
Truss Type
Common
Qty
6
Ply
1
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:14 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-dr0MhC3P8x?jqKU1Ke3F0Nb6QwU7anQUWb9VfXzM?sN
Scale = 1:37.5
T1 T1
B1
W1
W3W2W3W2
B1
A
B
C
D
E
F
G
J I H
4x6
4x4
5x8 1.5x4
3x4
1.5x4
3x4
4x4
5-3-4
5-3-4
10-6-8
5-3-4
15-9-12
5-3-4
21-1-0
5-3-4
-1-4-0
1-4-0
5-3-4
5-3-4
10-6-8
5-3-4
15-9-12
5-3-4
21-1-0
5-3-4
22-5-0
1-4-0
0-4-35-7-70-4-36.00 12
Plate Offsets (X,Y)-- [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.30
0.26
0.36
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.07
-0.10
0.04
0.03
(loc)
I
I-J
F
I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 93 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-10-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1147/0-5-8 (min. 0-1-8), F=1147/0-5-8 (min. 0-1-8)
Max HorzB=105(LC 12)
Max UpliftB=-235(LC 8), F=-235(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1766/306, C-D=-1212/240, D-E=-1212/240, E-F=-1766/306
BOT CHORD B-J=-292/1479, I-J=-292/1479, H-I=-188/1479, F-H=-188/1479
WEBS D-I=-84/580, E-I=-580/215, C-I=-580/214
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=235,
F=235.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
ANDERS VARGASON - WHITW~H
Truss
B03GD
Truss Type
COMMON GIRDER
Qty
1
Ply
3 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:16 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-ZD876u5fgZGR4edQS26j6ogLEk_I2a?mzvebkQzM?sL
Scale = 1:34.9
T1 T1
B1
W1
W3 W2 W2 W3
B1
HW1 HW1A
B
C
D
E
H G FI J K L M N O P Q
4x12
5x8
4x12 10x20 MT20HS3x10
4x8 4x8
3x10
5-3-4
5-3-4
10-6-8
5-3-4
15-9-12
5-3-4
21-1-0
5-3-4
5-3-4
5-3-4
10-6-8
5-3-4
15-9-12
5-3-4
21-1-0
5-3-4
0-4-35-7-70-4-36.00 12
Plate Offsets (X,Y)-- [A:0-3-8,0-1-15], [E:0-3-8,0-1-15]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.73
0.98
0.80
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.27
-0.37
0.11
0.13
(loc)
F-G
F-G
E
F-G
l/defl
>923
>662
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 319 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W1: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEDGE
Left: 2x4 DF Stud/Std , Right: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-3-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
REACTIONS.(lb/size) A=10639/0-5-8 (min. 0-3-13), E=11614/0-5-8 (min. 0-4-2)
Max HorzA=-92(LC 32)
Max UpliftA=-2062(LC 8), E=-2250(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-19736/3810, B-C=-13348/2597, C-D=-13349/2598, D-E=-19851/3833
BOT CHORD A-I=-3427/17512, I-J=-3427/17512, H-J=-3427/17512, H-K=-3427/17512, K-L=-3427/17512,
L-M=-3427/17512, G-M=-3427/17512, G-N=-3356/17619, N-O=-3356/17619, F-O=-3356/17619,
F-P=-3356/17619, P-Q=-3356/17619, E-Q=-3356/17619
WEBS C-G=-2184/11391, B-H=-992/5371, B-G=-6334/1338, D-G=-6452/1362, D-F=-1011/5466
NOTES-
1) Special connection required to distribute bottom chord loads equally between all plies.
2) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Unbalanced roof live loads have been considered for this design.
5) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable
end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=2062,
E=2250.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2023 lb down and 399 lb up at
2-0-12, 2023 lb down and 399 lb up at 4-0-12, 2023 lb down and 399 lb up at 6-0-12, 2023 lb down and 399 lb up at 8-0-12, 2023 lb
down and 399 lb up at 10-0-12, 2023 lb down and 399 lb up at 12-0-12, 2023 lb down and 399 lb up at 14-0-12, 2023 lb down and 399
lb up at 16-0-12, and 2023 lb down and 399 lb up at 18-0-12, and 2024 lb down and 397 lb up at 20-0-12 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
Continued on page 2
Job
ANDERS VARGASON - WHITW~H
Truss
B03GD
Truss Type
COMMON GIRDER
Qty
1
Ply
3 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 29 13:34:16 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:1Q2?lhCRV76MpzhAD?nC_yzM0lw-ZD876u5fgZGR4edQS26j6ogLEk_I2a?mzvebkQzM?sL
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, C-E=-84, A-E=-14
Concentrated Loads (lb)
Vert: F=-2023(B) I=-2023(B) J=-2023(B) K=-2023(B) L=-2023(B) M=-2023(B) N=-2023(B) O=-2023(B) P=-2023(B) Q=-2024(B)