HomeMy WebLinkAboutCAREFREE LIVING - HEALTH CARE CENTER - REVIEWS0 19 Rexburg Planning Board Rexburg, Idaho May 22 .1 1985 Dear Sirs, 83440 Af ter reviewing the blue prints for the Hea-Ith Care Center and Carefree Development, I feel that there should be no potential Probleins with the site location as pertains to the fire department, Previous to esentaLve of the actual construction., I would appreciate a repr- the Architect.9 Burns/Peters Group'. meeting wPt h myself and the fire inspector, Gordon Tychsen. At that meeting several quest -ions concerning fire protection for the complex needs to be answered., Sincerely, 1, V. Rex Larsen (Fire chief) F I R , El" ___W -------- I -E P A R T M E N T Needs to have a complete sprinkler system installed,, Patio doors do not Comply as exit doors. a Dining, Room does not have enough exits.. (Patio doors are used for All hallways must have automatic fire Closing doors., Multi --purpose room does not have cnough outside exits, Fire extinguisher must be provided in each room, All rooms need smoke detectors,, 1- S (Patio doors.) A f ire alarm with pull stations must be connected to . fire station, Only one way out of Recreat"on Room., Needs two exits and kitchen C e 0 n' Kitchen cooking hoods must have 311 clearances and automatic extinguisher, All stairs must have doors top and bottom, No sLores ge under stairsft Needs one hour fire proof walls in stair welIs. Sidewalk down the middle of the two complexes needs to be wide enough for a f ire truck to drive 'Gordon L. Tyehsen - Fj IM A Inspector L Dining, Room does not have enough exits.. (Patio doors are used for All hallways must have automatic fire Closing doors., Multi --purpose room does not have cnough outside exits, Fire extinguisher must be provided in each room, All rooms need smoke detectors,, 1- S (Patio doors.) A f ire alarm with pull stations must be connected to . fire station, Only one way out of Recreat"on Room., Needs two exits and kitchen C e 0 n' Kitchen cooking hoods must have 311 clearances and automatic extinguisher, All stairs must have doors top and bottom, No sLores ge under stairsft Needs one hour fire proof walls in stair welIs. Sidewalk down the middle of the two complexes needs to be wide enough for a f ire truck to drive 'Gordon L. Tyehsen - Fj IM A Inspector JOHN C. PORTER MAYOR ROSE SAGLEY, CLERK RICHARD HORNER. TREASURER The curb PHONE 356-19331 12 NORTH CENTER ST. REXBURGo IDAHO 83440 May 22,, 1985 only recommendation that and gutter be required., I would make that Signed: Farrell Davidson, Public Works Director