HomeMy WebLinkAboutCOMCHECK - 22-00059 - Java EspressCOMcheck Software Version 4.1.5.1
Interior Lighting Compliance Certificate
Project Title:
2018 IECC
Project Type:New Construction
Construction Site:
565 N. 2nd E.
Rexburg, ID 83440
Owner/Agent:Designer/Contractor:
Payne Engineering
1823 E Center St
Pocatello, ID 83201
208-232-4439
Project Information
Energy Code:
Java Espress
High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist
report.
Additional Efficiency Package(s)
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Dining: Bar Lounge/Leisure 805 0.90 724
725Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
1-Dining: Bar Lounge/Leisure
LED 1: F1: 2FT LED STRIP: Other:1 1 15 15
LED 2: F2/F2E: 6" ROUND RECESSED LED CAN: Other:1 23 25 575
LED 3: F3: 2FT LINEAR WALL FIXTURE: Other:1 1 18 18
LED 4: F4: LED MONOPOINT PENDANT: Other:1 3 10 30
638Total Proposed Watts =
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES: Design 12% better than code
Project Title:
Data filename:
Java Espress
\\PAYNEFILESERVER\Main File Storage\2021\Java Espress Rexburg -
21121\05_Calculations\Comcheck\Lighting Comcheck_Java Express Rexburg.cck
01/03/22Report date:
61 ofPage