HomeMy WebLinkAboutFlOOR LAYOUT - 21-01028 - 1020 Cypress Loop - New SFR16"oc
Start
J8J4
J2J1J3 J3 J5 J7 J6
FB1
FB2 FB3
R1R1 R1R1 R1R1
R1R1 R1R1
R1R1
R1R1R1R1R1R1R1 HGR1
HGR1
HGR1HGR2-ws
HGR1
HGR1
Project
SPREX-2021-098
Layout Name
Moulton
Builder's Project
Moulton
Plan Name
Brad & Jamee Moulton
Shipping
Pine Brooks Estates 26
Rexburg, ID 834401, USA
Builder
TWebb Construction
Dealer
SunPro Rexburg
Capital Lumber
41 South 5100 West
Salt Lake City, UT
USA
84104
(801) 834-5141
Sales Rep
Jason Kelly
Designer
Charlie Booth
Main Floor Framing
I Joist
Label Description Width Depth Qty Plies Pcs Length
J1 RFPI 400 2.063 11.875 2 16-0-0
J2 RFPI 400 2.063 11.875 6 18-0-0
J3 RFPI 400 2.063 11.875 16 30-0-0
J4 RFPI 400 2.063 11.875 9 6-0-0
J5 RFPI 400 2.063 11.875 7 38-0-0
J6 RFPI 400 2.063 11.875 9 34-0-0
J7 RFPI 400 2.063 11.875 2 36-0-0
J8 RFPI 400 2.063 11.875 11 10-0-0
Rim Board
Label Description Width Depth Qty Plies Pcs Length
R1 Tolko Rim Board Plus
1.125 X 11.875
1.125 11.875 16 16-0-0
LVL/LSL
Label Description Width Depth Qty Plies Pcs Length
FB1 2.1E Rigidlam LVL
DF
1.75 11.875 1 10-0-0
FB2 2.1E Rigidlam LVL
DF
1.75 11.875 1 2 2 14-0-0
FB3 2.1E Rigidlam LVL
DF
1.75 11.875 1 3 3 16-0-0
Hanger
Beam/Girder Supported
Member
Label Pcs Description Skew Slope fasteners fasteners
HGR1 43 IUS2.06/11.88
(Min)
10 10d
HGR2 3 IUS2.06/11.88
(Max)
10 10d 2 10dx1 1/2
Decking
Qty Description
60 Sheets 23/32" OSB
Main Floor Framing
Design Method ASD (USA)
Building Code IBC 2018
Floor
Loads
Live 40
Dead 10
Deflection Joist
LL Span L/480
TL Span L/240
Deflection Flush Girder
LL Span L/480
TL Span L/240
Deflection Dropped Girder
LL Span L/480
TL Span L/240
Deflection Header
LL Span L/480
TL Span L/240
Decking
Decking OSB
23/32 APA Rated
Sturd-I-Floor
Fastener Nailed & Glued
1.JOIST TO BE SPACED AT 16"OC (TYPICAL)
2.NO ROOF LOADS HAVE BEEN APPLIED TO THIS FLOOR
Version 21.80.417 Powered by iStructDataset: 21043001.1427 This placement plan is to be used as an installation guide only. It is meant to be used in conjunction with the manufacturers installation guide, the architectural and structural drawings, and not to replace them.