Loading...
HomeMy WebLinkAboutPLANS REDLINED REVISIONS - 21-00336 - Fit 1 Gym - RemodelAuthor Name Author Email Author Phone No.: Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : 664 N 2nd E - Fit 1 - Gym RemodelAddress : 664 N 2nd EApplication Type : Document Filename : Permit Set - May 12.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments G1.1 - Sheets Free text Cody Jones : Building Open 1 Need plans for construction. G1.2 - GENERALACCESSIBILITYREQUIREMENTS Free text Cody Jones : Building Open 2 As per Section 110.4.9.3 At least one of each type of exercisemachine and equipment shall be on an accessible route. G1.2 - GENERALACCESSIBILITYREQUIREMENTS Free text Cody Jones : Building Open 2 Seating at tables, counters and work areas comply with section1109. G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 2018 G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 Landings at doors need to meet requirements of 1010.1.5 and1009.6. G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 Exit lighting and Exit signs need to comply with IBC 1008 and1013. # 21-00336Commercial - Remodel Report Date: 05.25.2021 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 Glass and Glazing needs to meet requirements of Chptr 24.Bearing Walls need to be anchored to floor. G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 Footings if need for bearing walls will need documentation.Mezzanine needs to comply with section 505. G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 Need structural plans for mezzanine area. G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 ? G1.3 - BUILDINGCODEINFORMATION Free text Cody Jones : Building Open 3 Occupant load signs to be posted in all assembly buildings androoms. A1.2 Free text Cody Jones : Building Open 5 Hand rails and guards need to meet the requirements of 1014and 1015. Report Date: 05.25.2021 Approval of plans does not constitute approval of variance from code Page 2 of 2 AREA MAP PROJECT SITE DRAWING INDEX 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : OF PRE L IM IN A RY NO T F OR CO NS T RUCTION 5/12/2021 9:57:25 PM S:\Drawings\856-Ace & Chase\07-BIM\Ace & Chase.rvtG1.1 CO V E R S H E E T 856 AC E & C H A S E G Y M MAY 2021 JRN BAM 7 RE X B U R G , ID A H O 66 4 N 2 N D E , R E X B U R G , I D 8 3 4 4 0 REXBURG,IDAHO ACE & CHASE GYM G1.1 COVER SHEET G1.2 GENERAL ACCESSIBILITY REQUIREMENTS G1.3 BUILDING CODE INFORMATION A1.1 1ST FLOOR PLAN A1.2 2ND FLOOR PLAN GENERAL ARCHITECTURAL Need plans for construction. CL LC C L LC LC LC C L LC #304 ROOM WASTE TOWELS TOWELS WASTE VEND. WASTE 48 " A F F M A X 48 " A F F M A X 48 " A F F M A X TO O P E R A B L E CO N T R O L S T Y P TO D I S I P N S I N G OU T L E T T Y P TO D I S I P N S I N G OU T L E T T Y P 48 " A F F M A X TO D I S I P N S I N G OU T L E T T Y P 48 " A F F M A X TO OP E N I N G 19 " A F F M I N 27 " A F F M A X 19 A F F M I N 27 " A F F M A X TOWEL DISPENSER & WASTE RECEPTACLE TOWEL DISPENSER HAND DRYER SANITARY PRODUCTS VENDOR WASTE RECEPTACLE TISSUE DISPENSER NAPKIN DISPOSAL NOTE:PROVIDE A MIN CLEAR FLOOR SPACE OF 30"x48" AT APPROACH ALONG AN ACCESSIBLE ROUTE. 3 3 " M I N 3 6 " M A X 12" MAX 3'-8" MIN 36" MAX 39" - 41" 3 9 " - 4 1 " 1 8 " M A X 1 7 " - 1 9 " 1 1/4" TO 1 1/2" O.D. GRAB BAR (TYP) 18" MIN 36" MIN 6" MAX TOILET TOILET 1 1/2" MIN CLEAR TO WALL OR DISPENSERS T O D I S P . O U T L E T 4 8 " M A X T O M I R R O R 3 8 " M A X 9 " M I N MIN CLR WIDTH 2' - 6" 2 9 " M I N 3 4 " M A X BO T T O M O F AP R O N TO P O F R I M INSULATE ALL EXPOSED PIPES NOTE:FLUSH VALVE HANDLE ON WIDE SIDE OF TOILET, 44" AFF MAX. NOTE:GRAB BARS MUST NOT ROTATE WITHIN THEIR FITTINGS. STANDARD ACCESSIBILITY:1. ALL DOORS IN THE PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH ANSI A117.1, INCLUDING NECESSARY MANEUVERING CLEARANCES AND ACCESSIBLE DOOR HARDWARE. THIS INCLUDES THE EXTERIOR SIDE OF THE MAIN ENTRY DOORS TO DWELLING UNITS.2. ALL DOORS SHALL HAVE 32" MIN CLEAR WIDTH WHEN DOOR IS OPEN 90 DEGREES.3. ALL PLUMBING FIXTURES AND APPLIANCES IN DWELLING UNITS SHALL HAVE MIN 30" x 48" CLEAR FLOOR SPACE AS REQUIRED BY FHA.4. ALL PLUMBING FIXTURES, APPLIANCES, AND TELEPHONES IN PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH ADA, IBC, AND ANSI 117.1. 6" MAX TOE 17" MIN 2 7 " M I N 2 9 " M I N BO T T O M O F AP R O N 3 4 " M A X AF F T O T O P O F RI M 8" MINKNEE CLEARANCE CLEARANCE 9 " M I N 6" MAX 8" MIN 2 7 " M I N O F S P O U T 3 6 " M A X T O P 17"-19" 5 ' - 0 " A F F MOUNT SIGNS AT LATCH SIDE OF DOOR, OR NEAREST ADJACENT WALL. AT WALL18" MIN CLR WIDTH30" MIN T O P O F R I M 1 7 " M A X FACE OF FINISHED WALL NOTES:1. FLUSH VALVE HANDLE AT 44" AFF MAX.2. 30" x 48" MIN CLR FLR SPACE AT APPROACH3. 5 LBS MAX FORCE TO OPERATE FLUSH VALVE.4. 14" MIN PROJECTION FROM WALL. 1 5 " M I N 4 8 " M A X ELEC. OUTLET SWITCHES, THERMOSTATS, ETC. LAVATORY, MIRROR, AND SOAP DISPENSER LAVATORY DRINKING FOUNTAIN PERMANENT ROOM SIGNAGE URINAL ELECTRICAL DEVICES NOTE:18" MIN CLR FROM WALL TO OF LAVATORYLC NOTE:PROVIDE MIN CLEAR FLOOR SPACE OF 30" x 48" WITH 19" MAX EXTENDING UNDER LAV./D.F. TO INSULATED PIPING/PLUMBING. NOTE:FAUCETS MUST BE LEVER TYPE, ELECTRONICALLY ACTIVATED, OR APPROVED SELF-CLOSING VALVES (MIN 10 SEC. OPEN FLOW), AND BE OPERABLE w/ ONE HAND, NOT REQUIRING TIGHT GRASPING, PINCHING, OR TWISTING OF WRIST. 5 LBS. MAX FORCE REQUIRED TO ACTIVATE CONTROLS. FINISH FLOOR TYP.FINISH FLOOR TYP.FINISH FLOOR TYP. 0 ' - 9 " 3 3 " - 3 6 "3 " - 6 " 1 ' - 6 " CONTROL END ELEVATION BACK WALL ELEVATION PLAN VIEW 3 3 " - 3 6 " 3 3 " - 3 6 "3 " - 6 " 1 ' - 6 " 1 ' - 0 " 24" MAX 24" MIN 12" MAX 4 " M A X 2 4 " M I N BACK WALL HE A D E N D W A L L CO N T R O L EN D W A L L 1 5 " M I N 4 8 " M A X 20" MAX 4 8 " M A X >20"-25" 4 4 " M A X 10" MAX 4 8 " M A X 1 5 " M I N . 10" MAX 3 4 " M A X 4 8 " M A X 3 4 " M A X 4 8 " M A X >10"-24" 48" MIN 19" MAX 2 7 " M I N 3 4 " M A X 17" MIN 4 0 " M A X 3 4 " M A X 2 7 " M I N 9 " M I N 6" MAX8" MIN GUIDANCE FOR KNEE SPACES IN "A" BATHROOMSGUIDANCE FOR KNEE SPACES IN "B" BATHROOMS KNEE SPACE AT LAVATORIESOBSTRUCED HIGH SIDE REACHUNOBSTRUCTED SIDE REACHOBSTRUCTED HIGH FORWARD REACHUNOBSTRUCTED FORWARD REACH 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF PRE L IM IN A RY NO T F OR CO NS T RUCTION 5/12/2021 9:57:26 PM S:\Drawings\856-Ace & Chase\07-BIM\Ace & Chase.rvt G1.2 GE N E R A L A C C E S S I B I L I T Y R E Q U I R E M E N T S 856 AC E & C H A S E G Y M MAY 2021 JRN BAM RE X B U R G , ID A H O 66 4 N 2 N D E , R E X B U R G , I D 8 3 4 4 0 7 SCALE:3/8" = 1'-0" Standard Accessibility Installation Requirements SCALE:1/2" = 1'-0" Typical Clearance Requirements As per Section 110.4.9.3 At least one of each type of exercise machine and equipment shall be on an accessible route. Seating at tables, counters and work areas comply with section 1109. UP DN OCCUPANCY AND AREA OCCUPANCY LOAD FACTOR TOTAL OCCUPANT LOAD EXERCISE ROOMS -XXXX S.F. LOCKER rOOMS -XXXX S.F. 1/50 1/50 XXX XXX TOTAL OCCUPANT LOAD:XXX OCCUPANT LOAD SERVED BY EXIT BUTNOT COUNTED IN TOTAL OCCUPANT LOAD. ROOM OCCUPANT LOAD116 208 U SYMBOL DESCRIPTION 150 SF ROOM SQUARE FOOTAGES OCCUPANT LOAD SERVED BY EXIT OCCUPANCY GROUPS(CHAPTER 3) 2015 IBC CODE INFORMATION CODE ITEMREFERENCE CODEREQUIREMENT ACTUALBUILDING DESIGN A-3SECTIONS 304 A-3 CONSTRUCTION TYPE(CHAPTER 6)TYPE III-B, non-SPRINKLED TYPE III-B, non-SPRINKLED ALLOWABLEFLOOR AREA(TABLE 506.2) TABLE 506.2BASE ALLOWABLE AREA = 9,500 SF ACTUAL AREA = 7,911 SF STORIES & MAXIMUM HEIGHT(TABLE 504.3 & 504.4) 2 STORIES, 55 FEET 2 STORies, 20'-0" ROOF COVERING(TABLE 1505.1)CLASS CFIRE-RESISTANCE CLASS CFIRE-RESISTANCE EGRESS WIDTH(SECTION 1005.3.2)WITHout SPRINKLER SYSTEM:0.2" / OCCUPANT33.6" REQURIED ACCESSIBLE ENTRANCE (SECTION 1105.1)AT LEAST 60% BUT NOTLESS THAN 1 PROVIDED 144" PROVIDED -1ST LEVEL SYMBOL LEGEND WATER CLOSETS (INCLUDES URINALS)LAVS DRINKING FOUNTAINS PLUMBING FIXTURE COUNT REQUIRED FIXTURES (168 OCCUPANTS) MEN WOMEN MEN WOMEN 1 2 2 3 3 PROCESSING & OFFICE RESTROOMS PROVIDED FIXTURES 84 / 125 = 0.67 84/500 = 0.17 SYMBOL DESCRIPTION exit accesstravel distance MEANS OF EGRESS COMMON PATH OF EGRESS TRAVEL 300 FEET ALLOWABLE 100 FEET ALLOWABLE REQUIREMENT ACTUAL DESIGN 161 FT -1ST136 ft -2ND ROOF DRAFTSTOPS NONE none 84 / 65 = 1.29 84 / 200 = 0.42 84 / 200 = 0.42 46.5 FT -1ST52.5 ft -2ND 158 7911 S.F. 7' - 6" 10 491 S.F. 1 1 5 2 B O N D A V E N U E - S u i t e A R E X B U R G , I D A H O 8 3 4 4 0 V O I C E (2 0 8 ) 3 5 9 -2 3 0 9 F A X (2 0 8 ) 3 5 9 -2 2 7 1 W W W .J R W A .C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF PRE L IM IN A RY NO T F OR CO NS T RUCTION 5/12/2021 9:57:27 PM S:\Drawings\856-Ace & Chase\07-BIM\Ace & Chase.rvt G1.3 BU I L D I N G C O D E I N F O R M A T I O N 856 AC E & C H A S E G Y M MAY 2021 JRN BAM RE X B U R G , ID A H O 66 4 N 2 N D E , R E X B U R G , I D 8 3 4 4 0 7 2018 Landings at doors need to meet requirements of 1010.1.5 and 1009.6. Exit lighting and Exit signs need to comply with IBC 1008 and 1013. Glass and Glazing needs to meet requirements of Chptr 24. Bearing Walls need to be anchored to floor. Footings if need for bearing walls will need documentation. Mezzanine needs to comply with section 505. Need structural plans for mezzanine area. ? Occupant load signs to be posted in all assembly buildings and rooms. DN 9' - 0 " 19 ' - 1 0 " 4' - 8 " 26 ' - 1 0 3 / 4 " 15' - 10" 7' - 4 1/8"8' - 2 3/8" tanning bed 1 DOUBLE 36" DOOR WITH PUSH/PULL HARDWARE. KEYED DEADBOLT. SIGNAGE: "DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." 2 36" DOOR WITH LEVER HANDLE. 3 36" DOOR WITH KEYED LEVER HANDLE. 4 36" DOOR WITH PRIVACY LOCK LEVER HANDLE. 5 DOUBLE 36" DOOR WITH KEYED LEVER HANDLE. 6 INSULATED SECTIONAL DOOR WITH LITES. 4 3 3 2 A1.2 CARDIO LOFT 5 STORAGE 6 TANNINGROOM 7 ACCESS 4 0' - 6 3 / 4 " 1' - 0" 0' - 3" 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF PRE L IM IN A RY NO T F OR CO NS T RUCTION 5/17/2021 9:25:24 AM S:\Drawings\856-Ace & Chase\07-BIM\Ace & Chase.rvt A1.2 2N D F L O O R P L A N 856 AC E & C H A S E G Y M MAY 2021 JRN BAM RE X B U R G , ID A H O 66 4 N 2 N D E , R E X B U R G , I D 8 3 4 4 0 7 NORTH SCALE:1" = 1'-0"A1.2 2STAIR SECTION Hand rails and guards need to meet the requirements of 1014 and 1015.