HomeMy WebLinkAboutPLANS APPROVED - 21-00047 - Madison Memorial Hospital - BHU RemodelAuthor Name Author Email Author Phone No.: Bret Stoddard brets@rexburg.org 208-372-2171 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Madison Memorial Hospital - BHU RemodelAddress : 450 E Main StRecord Type : Commercial - RemodelDocument Filename : 00) 778-BH- FULL SET.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00047 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments G1.3 Free text Cody Jones : Building Open 3 Exit access travel distance for an I2 is 200' G1.3 Free text Cody Jones : Building Open 3 Fire extinguishers should be located a maximum distance oftravel of 75' G1.3 Free text Cody Jones : Building Open 3 407.3 Corridor walls shall be constructed as smoke partitions. A1.3 Free text Cody Jones : Building Open 8 Suspended ceiling to be installed to manufacturersspecifications. A4.1 Free text Cody Jones : Building Open 9 Frost line depth of 36" E1.0 Free text Cody Jones : Building Open 25 Exit lighting and Exit signs to be in compliance with IBC Section1008 and 1013 Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) G 1 . 3 C O D E S H E E T - F I R E / S M O K E P L A N Exit access travel distance for an I2 is 200' Fire extinguishers should be located a maximum distance of travel of 75' 407.3 Corridor walls shall be constructed as smoke partitions. 95.78 ft 9 6 . 1 9 f t Suspended ceiling to be installed to manufacturers specifications. Frost line depth of 36" P L A N N O T E S : 1 E X I S T I N G P L U M B I N G F I X T U R E T O R E M A I N . P R O T E C T F I X T U R E D U R I N G C O N S T R U C T I O N A N D M A I N T A I N C O N N E C T I O N T O E X I S T I N G W A S T E , W A T E R A N D V E N T P I P I N G . D I S C O N N E C T A N D R E M O V E E X I S T I N G P L U M B I N G F I X T U R E A S I N D I C A T E D . M O D I F Y E X I S T I N G W A S T E , W A T E R A N D V E N T R O U G H - I N S A S R E Q U I R E D F O R N E W F I X T U R E T O B E I N S T A L L E D . R E F E R T O S H E E T P 1 . 1 F O R N E W F I X T U R E . D I S C O N N E C T A N D R E M O V E E X I S T I N G P L U M B I N G F I X T U R E A S I N D I C A T E D . C A P E X I S T I N G W A S T E P I P I N G B E L O W F L O O R A S R E Q U I R E D . R E M O V E E X I S T I N G W A T E R A N D V E N T P I P I N G U P I N W A L L S A N D A B O V E C E I L I N G . C A P E X I S T I N G P I P I N G N E A R M A I N L I N E S . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N O F A L L E X I S T I N G P I P I N G . A P P R O X I M A T E L O C A T I O N O F E X I S T I N G W A S T E P I P I N G B E L O W F L O O R . R E F E R T O A R C H I T E C T U R A L D R A W I N G S F O R C U T T I N G A N D P A T C H I N G O F E X I S T I N G C O N C R E T E F L O O R S . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T L O C A T I O N S O F P I P I N G W H E R E F L O O R S A R E C U T A N D P R O T E C T P I P I N G D U R I N G C O N S T R U C T I O N . E X I S T I N G W A T E R A N D V E N T P I P I N G A B O V E C E I L I N G S T O R E M A I N U N L E S S N O T E D O T H E R W I S E . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F E X I S T I N G P I P I N G A N D C O O R D I N A T E W I T H N E W P I P I N G A N D D U C T W O R K . R E F E R T O S H E E T P 1 . 1 F O R W A T E R A N D V E N T P I P I N G T O B E C O N N E C T E D T O E X I S T I N G . C O O R D I N A T E C U T T I N G O F E X I S T I N G C O N C R E T E F L O O R W I T H G E N E R A L C O N T R A C T O R T O R E M O V E E X I S T I N G F L O O R D R A I N . C A P E X I S T I N G W A S T E L I N E B E L O W F L O O R . R E F E R T O S H E E T P 1 . 1 F O R A N Y N E W F L O O R D R A I N S T O B E I N S T A L L E D A N D C O N N E C T E D T O E X I S T I N G U N D E R F L O O R P I P I N G . D I S C O N N E C T E X I S T I N G W A T E R A N D V E N T P I P I N G F R O M F I X T U R E A B O V E A N D R E M O V E E X I S T I N G P I P I N G U P I N W A L L S . A B A N D O N P I P I N G B E L O W F L O O R . E X I S T I N G 2 " V E N T U P T H R U F L O O R A B O V E T O R E M A I N . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T L O C A T I O N A N D S I Z E O F P I P I N G . R E F E R T O S H E E T P 1 . 1 F O R N E W V E N T P I P I N G T O B E C O N N E C T E D T O E X I S T I N G R I S E R . E X I S T I N G 4 " R O O F D R A I N L I N E D O W N F R O M A B O V E T O R E M A I N . E X I S T I N G H O R I Z O N T A L P I P I N G T O B E R E - R O U T E D T O N E W W A L L . R E M O V E E X I S T I N G V E R T I C A L P I P I N G I N E X I S T I N G W A L L O N M A I N L E V E L . R E F E R T O S H E E T P 1 . 1 F O R N E W H O R I Z O N T A L P I P I N G A N D N E W V E R T I C A L D R O P I N N E W W A L L . C O O R D I N A T E C U T T I N G A N D P A T C H I N G O F E X I S T I N G C O N C R E T E F L O O R W I T H G E N E R A L C O N T R A C T O R F O R R E - R O U T I N G O F P I P I N G B E L O W F L O O R . D I S C O N N E C T A N D R E L O C A T E E X I S T I N G I N S T A N T A N E O U S W A T E R H E A T E R A N D A L L A S S O C I A T E D P I P I N G . C A P E X I S T I N G W A T E R L I N E S A B O V E C E I L I N G . R E F E R T O S H E E T P 1 . 1 F O R N E W L O C A T I O N O F E X I S T I N G W A T E R H E A T E R . E X I S T I N G M E D G A S P I P I N G A B O V E C E I L I N G T O R E M A I N . C L O S E E X I S T I N G S H U T - O F F V A L V E S A N D S E C U R E C L O S E D P O S I T I O N . A L L E X I S T I N G M E D G A S P I P I N G I N T H I S A R E A T O B E A B A N D O N E D I N P L A C E U N L E S S N O T E D O T H E R W I S E . E X I S T I N G M E D G A S E M E R G E N C Y S H U T - O F F V A L V E B O X A N D P I P I N G T O B E R E M O V E D . D I S C O N N E C T E X I S T I N G O X Y G E N , M E D A I R , A N D V A C U U M P I P I N G A B O V E C E I L I N G N E A R M A I N L I N E S A N D C A P A C T I V E P I P I N G . R E M O V E A L L U N U S E D P I P I N G A B O V E C E I L I N G A N D D O W N W A L L S . E X I S T I N G H E A D B O A R D A N D / O R W A L L M O U N T E D M E D G A S O U T L E T S T O B E R E M O V E D . D I S C O N N E C T E X I S T I N G M E D G A S P I P I N G A B O V E C E I L I N G A N D C A P N E A R M A I N L I N E S . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S , L O C A T I O N S A N D Q U A N T I T Y O F M E D G A S L I N E T O E A C H H E A D B O A R D . P R O V I D E C A P S T O M A T C H L I N E S I Z E S . C U T E X I S T I N G M E D G A S P I P I N G A S T H I S L O C A T I O N A B O V E C E I L I N G A N D C A P L I N E S . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F E X I S T I N G M E D G A S P I P I N G . P R O V I D E C A P S T O M A T C H E X I S T I N G L I N E S I Z E S A N D M A T E R I A L . E X I S T I N G M E D G A S A L A R M S E N S O R S T O R E M A I N . D I S C O N N E C T E X I S T I N G A N D R E M O V E W I R I N G T O W A L L A L A R M P A N E L . A B A N D O N S E N S O R S I N P L A C E . E X I S T I N G M E D G A S A L A R M P A N E L T O B E D I S C O N N E C T E D A N D R E M O V E D . R E M O V E A L L E X I S T I N G W I R I N G I N W A L L S A N D A B O V E C E I L I N G S T O E X I S T I N G S E N S O R S . K E Y P L A N ( L E V E L 2 ) P R O J E C T L O C T I O N 2 3 4 3 T H R E E P 0 . 1 PLU M B I N G D E M O L I T I O N P L A N N o r t h SCALE: 3/16 " = 1 ' - 0 " 1 4 1 4 3 3 3 3 3 6 3 3 6 2 283333231323 3 1 3 22 2 2 2 3 1 3 6 13 1 3 1 3 A A A A A A A A A A A V V V V V V V V V V O O O O O O O O O OO O A A A A A A AVVVVVV VOOOOOOO A A A AOOO V V V A A A V V O O O AO V O O O A A A A V V V V A A A A A A AVVVVVVV O O O O O O O A A A A O O O O V V V A A A A O O O O V V V V O O O OAAAA AVVVV A A A A A V V V V O O O O V O A 1 3 1 3 F 2 R D L RDL 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 1 5 1 3 5 4 1 0 4 3 3 3 1 4 1 1 1 3 1 1 4 3 3 3 1 1 8 2 " V 1 1 1 4 5 5 5 5 7 7 1 3 1 3 1 4 8 2 " V 1 1 4 9 4 " R D L 3 3 3 4 5 1 1 3 1 1 5 4 3 8 4 1 1 5 1 2 1 2 1 2 1 5 1 1 1 1 4 2 " V 1 1 6 3 1 1 5 5 5 3 3 1 1 4 1 1 1 3 5 1 3 8 2 " V 4 4 7 1 5 3 4 7 1 6 1 1 7 8 2 " V 1 5 1 1 1 3 1 3 4 4 1 3 1 1 9 9 7 8 2 " V 4 4 4 3 3 5 5 2 EXISTING FCO 5 5 5 11 13 1311 5 55 55 5 222" V 444 1 3 3 3 4 5 5 6 3 4 1 4 1 4 5 5 5 11 14 131355582" V 11 14 2 5 82" V 5 4 M J E N S E N D S U D W E E K S 7 7 8 S E P T 2 0 2 0 E n g i n e e r e d S y s t e m s A s s o c i a t e s O c t 1 2 , 2 0 2 0 O R I G I N A L D R A W I N G S I G N E D B Y : D W A Y N E C . S U D W E E K S D A T E O R I G I N A L S I G N E D : O R I G I N A L O N F I L E A T E N G I N E E R E D S Y S T E M S A S S O C I A T E S 1 3 5 5 E A S T C E N T E R , P O C A T E L L O , I D A H O 8 3 2 0 1 O c t 1 2 , 2 0 2 0 1 0 P R O V I D E N E W H E A D S A N D / O R P I P I N G , O R R E L O C A T E E X I S T I N G F I R E S P R I N K L E R H E A D A N D / O R P I P I N G A S R E Q U I R E D T O M E E T N F P A - 1 3 C O D E R E Q U I R E M E N T S D U E T O R E M O D E L W O R K . P R O J E C T L O C T I O N T H R E E P 1 . 1 PLU M B I N G F L O O R P L A N N o r t h SCALE: 3/16 " = 1 ' - 0 " PATIENT RM230 T . R . 2 0 6 O F F I C E 2 1 4 P A T I E N T R M 2 1 7 P A T I E N T R M 2 2 0 P A T I E N T R M 2 3 3 V E S T 2 0 2 S E C L U S I O N 2 0 7 E X A M 2 1 5 C O R R I D O R 2 1 6 VEST222T.R.231 R E C ' P 2 0 1 S T A F F P A T I O 2 0 5 N U R S E 2 4 0 T.R.224PATIENT RM223 C O R R I D O R 2 3 6 M E D I A 2 3 5 V I S I T I N G 2 0 3 N U R S E W O R K R O O M 2 3 7 T.R.225 PATIENT RM226 C O R R I D O R 2 0 9 S T O R A G E 2 3 4 O F F I C E 2 0 4 M E D S 2 3 8 T.R.228 PATIENT RM229 T E A M R M 2 4 2 T . R . 2 3 2 E X I S T C O R R 2 0 0 N U R S E 2 3 9 S T A F F 2 4 1 E V S 2 4 3 G R O U P T H E R A P Y 2 1 1 D A Y R M 2 1 0 O B S E R V A T I O N 2 0 8 T H E R A P Y 2 1 3 T . R . 2 1 8 T . R . 2 1 9 M J E N S E N D S U D W E E K S 7 7 8 S E P T 2 0 2 0 E n g i n e e r e d S y s t e m s A s s o c i a t e s O c t 1 2 , 2 0 2 0 O R I G I N A L D R A W I N G S I G N E D B Y : D W A Y N E C . S U D W E E K S D A T E O R I G I N A L S I G N E D : O R I G I N A L O N F I L E A T E N G I N E E R E D S Y S T E M S A S S O C I A T E S 1 3 5 5 E A S T C E N T E R , P O C A T E L L O , I D A H O 8 3 2 0 1 O c t 1 2 , 2 0 2 0 P L A N N O T E S : K E Y P L A N ( L E V E L 2 ) W C - 1 WC-1 WC-1 WC-1 WC-1 W C - 2 W C - 1 W C - 1 W C - 1 S H - 3 L - 1 SH- 3 SH-1 SH-2 SH-2 S H - 3 I C E F S - 1 S - 1 S - 1 L-1 L-1 L-1 L-1 L - 1 L - 1 L - 1 3 22 2 2 L - 2 3 3 3 3 3 3 3 1 E X I S T I N G P L U M B I N G F I X T U R E T O R E M A I N . P R O T E C T F I X T U R E D U R I N G C O N S T R U C T I O N A N D M A I N T A I N C O N N E C T I O N T O E X I S T I N G W A S T E , W A T E R A N D V E N T P I P I N G . P R O V I D E A N D I N S T A L L N E W P L U M B I N G F I X T U R E A S S P E C I F I E D T O R E P L A C E E X I S T I N G . M O D I F Y E X I S T I N G W A S T E , W A T E R A N D V E N T R O U G H - I N S A S R E Q U I R E D F O R N E W F I X T U R E . C O N N E C T N E W F I X T U R E T O E X I S T I N G W A S T E , W A T E R A N D V E N T P I P I N G . P R O V I D E N E W S H U T - O F F V A L V E S O N W A T E R L I N E S . R E F E R T O S H E E T P 0 . 1 F O R E X I S T I N G F I X T U R E L O C A T I O N S . C O O R D I N A T E C U T T I N G A N D P A T C H I N G O F E X I S T I N G W A L L S A N D F L O O R W I T H G E N E R A L C O N T R A C T O R . P R O V I D E A N D I N S T A L L N E W P L U M B I N G F I X T U R E A S S P E C I F I E D . P R O V I D E N E W W A S T E P I P I N G B E L O W F L O O R A S R E Q U I R E D T O C O N N E C T T O E X I S T I N G . R I S E W A T E R A N D V E N T P I P I N G U P A B O V E C E I L I N G A N D C O N N E C T T O N E A R E S T E X I S T I N G V E N T P I P I N G O F S A M E S I Z E O R L A R G E R . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N O F A L L E X I S T I N G P I P I N G . P R O V I D E N E W S H U T - O F F V A L V E S A T F I X T U R E F O R A L L N E W W A T E R P I P I N G . C O O R D I N A T E C U T T I N G A N D P A T C H I N G O F E X I S T I N G W A L L S A N D F L O O R W I T H G E N E R A L C O N T R A C T O R . A P P R O X I M A T E L O C A T I O N O F E X I S T I N G W A S T E P I P I N G B E L O W F L O O R . R E F E R T O A R C H I T E C T U R A L D R A W I N G S F O R C U T T I N G A N D P A T C H I N G O F E X I S T I N G C O N C R E T E F L O O R S . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T L O C A T I O N S O F P I P I N G W H E R E F L O O R S A R E C U T A N D P R O T E C T P I P I N G D U R I N G C O N S T R U C T I O N . E X I S T I N G W A T E R A N D V E N T P I P I N G A B O V E C E I L I N G S T O R E M A I N U N L E S S N O T E D O T H E R W I S E . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F E X I S T I N G P I P I N G A N D C O O R D I N A T E W I T H N E W P I P I N G A N D D U C T W O R K . R E F E R T O S H E E T P 1 . 1 F O R W A T E R A N D V E N T P I P I N G T O B E C O N N E C T E D T O E X I S T I N G . P R O V I D E A N D I N S T A L L N E W W A S T E L I N E B E L O W E X I S T I N G C O N C R E T E F L O O R A S S H O W N F R O M N E W F I X T U R E T O E X I S T I N G W A S T E P I P I N G L O C A T I O N . C O O R D I N A T E C U T T I N G O F E X I S T I N G C O N C R E T E F L O O R W I T H G E N E R A L C O N T R A C T O R E X I S T I N G W A S T E L I N E B E L O W F L O O R . N E W W A S T E L I N E T O B E C O N N E C T E D T O N E A R E S T E X I S T I N G W A S T E L I N E O F S A M E ( O R L A R G E R ) S I Z E . P L U M B I N G C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F A L L E X I S T I N G P I P I N G O N J O B S I T E . P R O V I D E A N D I N S T A L L N E W V E N T L I N E S A N D H O T A N D C O L D W A T E R L I N E S A B O V E C E I L I N G A S S H O W N F R O M N E W F I X T U R E T O E X I S T I N G C O R R E S P O N D I N G P I P I N G O F E Q U A L ( O R L A R G E R ) S I Z E . P L U M B I N G C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F A L L E X I S T I N G P I P I N G O N J O B S I T E . E X I S T I N G 2 " V E N T U P T H R U F L O O R A B O V E T O R E M A I N . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T L O C A T I O N A N D S I Z E O F P I P I N G . P R O V I D E N E W V E N T P I P I N G A N D F I T T I N G S A S R E Q U I R E D T O C O N N E C T N E W F I X T U R E ( S ) T O E X I S T I N G V E N T R I S E . E X I S T I N G 2 " V E N T U P T H R U F L O O R A B O V E T O R E M A I N . F I E L D V E R I F Y E X A C T S I Z E A N D L O C A T I O N A N D C A P P I P I N G I N C E I L I N G S P A C E F O R F U T U R E C O N N E C T I O N ( S ) . E X I S T I N G 4 " R O O F D R A I N L I N E D O W N F R O M A B O V E T O R E M A I N . F I E L D V E R I F Y E X A C T S I Z E A N D L O C A T I O N O F E X I S T I N G P I P I N G I N C E I L I N G S P A C E . I N T E R R U P T E X I S T I N G H O R I Z O N T A L P I P I N G I N C E I L I N G S P A C E A N D R U N T O N E W W A L L A S S H O W N . D R O P N E W 4 " R O O F D R A I N L I N E D O W N I N N E W W A L L T O B E L O W F L O O R . C O O R D I N A T E C U T T I N G A N D P A T C H I N G O F E X I S T I N G C O N C R E T E F L O O R W I T H G E N E R A L C O N T R A C T O R F O R R E - R O U T I N G O F P I P I N G B E L O W F L O O R F R O M N E W D R O P T O E X I S T I N G P I P I N G I N E X I S T I N G L O C A T I O N . E X I S T I N G M E D G A S P I P I N G A B O V E C E I L I N G T O R E M A I N . C L O S E E X I S T I N G S H U T - O F F V A L V E S A N D S E C U R E C L O S E D P O S I T I O N . A L L E X I S T I N G M E D G A S P I P I N G I N T H I S A R E A T O B E C A P P E D A N D A B A N D O N E D I N P L A C E U N L E S S N O T E D O T H E R W I S E . I N T E R R U P T ( 2 ) E X I S T I N G 1 - 1 / 2 " C O N D E N S A T E D R A I N L I N E S F R O M H E A T P U M P S A B O V E C E I L I N G . E X T E N D ( 2 ) 1 - 1 / 2 " D R A I N L I N E S T O E X I S T I N G S E R V I C E S I N K I N R O O M 2 4 3 . D R O P P I P I N G D O W N I N W A L L A N D E X T E N D O U T T O S E R V I C E S I N K . F I E L D V E R I F Y E X A C T S I Z E A N D L O C A T I O N O F E X I S T I N G D R A I N L I N E S A B O V E C E I L I N G S . R E L O C A T E ( 2 ) E X I S T I N G I N S T A N T A N E O U S W A T E R H E A T E R S T O R O O M 2 4 3 A N D M O U N T O N W A L L . C O N N E C T T O E X I S T I N G H O T A N D C O L D W A T E R P I P I N G A B O V E C E I L I N G S . R E F E R T O P I P I N G D I A G R A M O N S H E E T P 3 . 1 F O R T Y P I C A L P I P I N G C O N N E C T I O N S . 2 3 4 2 28 33222 2 1 A A A A A A A A A A A A V V V V V V V V V V V O O O O O O O O O OO O A A A A A A AVVVVVV VOOOOOOO A A A AOOO V V V A A A V V O O O AO V O O O A A A V V V A A A A A A AVVVVVVV O O O O O O O A A A A O O O O V V V A A A A O O O O V V V V O O O OAAAA AVVVV A A A A A V V V V O O O O V O A F 3 R D L 5 6 7 8 9 1 0 1 1 1 2 1 3 1 3 5 5 4 4 1 3 1 3 4 1 3 8 2 " V 1 3 5 5 5 5 8 2 " V 1 3 4 1 0 4 " R D L 4 5 1 3 1 3 5 4 9 4 1 3 5 1 3 4 2 " V 1 3 1 3 5 5 5 1 3 4 1 3 5 8 2 " V 4 4 4 1 3 9 2 " V 1 3 4 4 1 3 1 1 1 2 9 2 " V 4 4 4 5 5 2 EXISTING FCO 5 5 5 1313 5 55 55 5 222" V 444 1 4 5 5 4 5 5 5 13 55582" V 13 2 5 82" V 5 4 2 4 2 1 3 3 S H - 3 2 6 645445544 4 7 1 / 2 " H & C 1 " C W 7 2 " V 7 4 2 " W 6 4 " W 6 4 5 5 4 5 4 R D L R D L 1 2 6 7 7 1 / 2 " C W 4 " W 2 " V 5 6 7 2 " W 1 / 2 " H & C 1 - 1 / 2 " V 7 4 " W 2 " W 6 2 " V 7 1 / 2 " H & C 6 1 / 2 " H & C 1 - 1 / 2 " V 1 / 2 " H & C 1 - 1 / 2 " V 4 4 P R O V I D E N E W H E A D S A N D / O R P I P I N G , O R R E L O C A T E E X I S T I N G F I R E S P R I N K L E R H E A D A N D / O R P I P I N G A S R E Q U I R E D T O M E E T N F P A - 1 3 C O D E R E Q U I R E M E N T S D U E T O R E M O D E L W O R K . C U P 2 CD C D CDCD 1 4 1 4 1 5 1 4 1 5 T H R E E P 3 . 1 M J E N S E N D S U D W E E K S 7 7 8 S E P T 2 0 2 0 E n g i n e e r e d S y s t e m s A s s o c i a t e s O c t 1 2 , 2 0 2 0 O R I G I N A L D R A W I N G S I G N E D B Y : D W A Y N E C . S U D W E E K S D A T E O R I G I N A L S I G N E D : O R I G I N A L O N F I L E A T E N G I N E E R E D S Y S T E M S A S S O C I A T E S 1 3 5 5 E A S T C E N T E R , P O C A T E L L O , I D A H O 8 3 2 0 1 O c t 1 2 , 2 0 2 0 L I G A T U R E W A T E R C L O S E T - W H I T E H A L L M A N U F A C T U R I N G M O D E L W H 2 1 4 5 W I T H S T A I N L E S S S T E E L C O N S T R U C T I O N A N D W H I T E F I N I S H , C O N C E A L E D S I P H O N J E T F L U S H W I T H E L O N G A T E D B O W L , A N D W H - L R S C - W H I T E S E C U R E D T O I L E T S E A T 2 " 4 " 1 / 2 " V E N T W A S T E - - - H O T C O L D S Y M . D E S C R I P T I O N SPRINKLER HEAD COORDINATION D E T A I L S NO SCALE SPRINKLERPIPING3" MIN.CLEARHVAC GRILLE ORREGISTERCEILINGSP R I N K L E R H E A D 6"' MIN.SPRINKLERPIPING3" MIN.CLEARCEILINGLIGHTFIXTUREPENDANTSPRINKLERHEADWHITE ESCHUTCHEONWITH WHITE EXTENSION WHITE ESCHUTCHEONWITH WHITE EXTENSIONRECESSED WHITEESCUTCHEON ATSUSPENDED CEILINGS SPRINKLERPIPING UPRIGHT SPRINKLERWHERE STRUCTURE ISEXPOSED OR IN ABOVECEILING INSTALLATIONS. W H I T E C A N O P Y E S C U T C H E O N C O N C E A L E D H E A D S W I T H C A P S P R I N K L E R P I P I N G R O O F S Y S T E M NOTE: B R A C E P I P I N G STEEL DECKQUICK ENDTHREADLESSBRACE FITTING (2PLCS)PROVIDE SEISMIC BRACING ONLY INSEISMICALLY ACTIVE AREAS. BRACINGSHALL CONFORM TO THEREQUIREMENTS OF NFPA 13 AND ALLSTATE AND LOCAL CODES.4-WAY SEISMIC BRACENO SCALE 2-WAY SE I S M I C B R A C E NO SCALE 1 / 2 " N U T , B O L T & W A S H E R ( 2 P L C S ) Q U I C K E N D T H R E A D L E S S B R A C E F I T T I N G Q U I C K C L A M P S W A Y B R A C E A T T A C H M E N T STEELBARJOISTBRACE PIPING (S PLCS)STEEL DECK 1/2" NUT, BOLT &WASHER (2 PLCS)QUICK CLAMP SWAYBRACE ATTACHMENT STEELBARJOISTQUICK 4-WAYLONGITUDINAL SWAYBRACE CLAMP H A N G E R D E T A I L N O S C A L E S T E E L R O O F D E C K 3 / 8 " A L L - T H R E A D R O D B R A N C H L I N E P I P E S T E E L S T R U C T U R E R E T A I N I N G S T R A P S T E E L S T R U C T U R E H A N G E R D E T A I L N O S C A L E B E A M C L A M P W I T H S E T S C R E W S T E E L R O O F D E C K B E A M C L A M P W I T H S E T S C R E W R E T A I N I N G S T R A P 3 / 8 " A L L - T H R E A D R O D B R A N C H L I N E P I P E C L E A N O U T D E T A I L S F L O O R C L E A N O U T ( F C O ) N O S C A L E C L E A N O U T T O G R A D E ( C O T G ) W A S T E L I N E F L O O R L I N E F I N I S H G R A D E 1 ' - 0 " W A L L C L E A N O U T ( W C O ) 1 / 8 B E N D F L O O R L I N E W A L L B R A S S C L E A N O U T P L U G W I T H C O U N T E R S U N K H E A D 1 6 " S Q U A R E C O N C P A D T R O W E L S M O O T H C L E A N O U T A N D A C C E S S C O V E R . T O P O F C O V E R T O B E F L U S H W I T H T O P O F F L O O R . B A L A N C E O F P I P I N G S A M E A S C L E A N O U T T O G R A D E . C L E A N O U T S H O U L D N O T B E L O C A T E D I N C A R P E T E D A R E A . 1 / 8 B E N D I F C L E A N O U T O C C U R S A T E N D O F L I N E . W A S T E L I N E . L E N G T H T O S U I T . C H R O M E W A L L C O V E R A N D S C R E W M A Y E X T E N D A S A W A S T E O R V E N T P L U G G E D T E E W I T H C L E A N O U T B A L A N C E O F P I P I N G S A M E A S C L E A N O U T T O G R A D E . 1 / 8 B E N D 1 / 8 B E N D W C - 1 L I G A T U R E W A L L M O U N T E D L A V A T O R Y - W H I T E H A L L M A N U F A C T U R I N G M O D E L W H 3 7 7 5 C O R T E R R A B A S I N W I T H 3 4 " R I M H E I G H T , B A C K A N D S I D E S P L A S H E S , G R I D S T R A I N E R , A N D C O N C E A L E D 1 - 1 / 2 " P - T R A P A N D W A S T E L I N E , A N D 1 / 2 " T E M P E R E D W A T E R V A L V E . P R O V I D E W H 3 3 7 7 H O T & C O L D F A U C E T W I T H 4 " C E N T E R S E T A N D ( 2 ) W H S T 7 0 - 1 2 T E M P E R A T U R E & P R E S S U R E B A L A N C I N G M I X I N G V A L V E S . 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " 1 / 2 " L - 1 A D A F L U S H V A L V E W A T E R C L O S E T - K O H L E R K - 9 6 0 5 7 - 0 " H I G H C L I F F " W I T H E L O N G A T E D B O W L , K - 4 6 7 0 - C O P E N F R O N T S E A T , S L O A N R E G A L F L U S H V A L V E A N D B O L T C A P S . 2 " 4 " 1 " - - - W C - 2 W A L L M O U N T E D L A V A T O R Y - K O H L E R K - 2 0 3 2 " G R E E N W I C H " S I Z E 2 0 x 1 8 W I T H K - 1 5 5 9 2 - 5 L E V E R H A N D L E F A U C E T , K - 7 7 1 5 O P E N G R I D S T R A I N E R , 1 / 2 " S T O P S A N D 1 - 1 / 4 " P - T R A P . P R O V I D E I N S U L A T I N G J A C K E T O N H W A N D W A S T E L I N E S . 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " 1 / 2 " L - 2 L I G A T U R E S H O W E R S T A L L - A Q U A T I C M O D E L 1 3 6 3 B F S O N E - P I E C E M O L D E D S H O W E R S T A L L W I T H C E N T E R D R A I N A N D F O L D - U P S E A T , W H I T E H A L L W H D G - Z N - 5 R D L I G A T U R E R E S I S T A N T D R A I N G R A T E W I T H 2 " D E E P S E A L P - T R A P , W H I T E H A L L W H 4 1 8 - F H - C S H F L U S H M O U N T S H O W E R W I T H D U A L H E A D S , W H S V 1 6 T E M P E R A T U R E / P R E S S U R E C O M P E N S A T I N G S H O W E R V A L V E , D I V E R T I N G V A L V E , A N D ( 2 ) W H I T E H A L L W H C S H 2 5 S H O W E R H E A D S 2 " 2 " 1 / 2 " 1 / 2 " S H - 1 S I N G L E C O M P A R T M E N T S I N K - E L K A Y M O D E L L R 1 9 1 8 S T A I N L E S S S T E E L S I N K W I T H T & S B R A S S M O D E L B - 2 8 6 5 - 0 4 G O O S E N E C K F A U C E T W I T H W R I S T B L A D E H A N D L E S , L K - 3 5 D U O S T R A I N E R , 1 / 2 " S T O P S A N D 1 - 1 / 2 " P - T R A P . 2 " 2 " 1 / 2 " 1 / 2 " S - 1 TANKLESS GAS-FIRED WATER HEATER P I P I N G D E T A I L NO SCALE TYP. BALL VALVEFLOOR ELECTRIC TANKLESSWATER HEATER 1/2" HOT AND CW SUPPLYPIPING TO WATER HEATER PENDANTSPRINKLERHEADPIPE FULL SIZE TOEXISTING JANITOR SINK I N D I R E C T D R A I N D E T A I L N O S C A L E F I N I S H E D F L O O R S E R V I C E S I N K I N D I R E C T W A S T E L I N E D O W N I N W A L L O R C H A S E E L B O W D O W N 9 0 ° T O R E C E P T O R . ( M A I N T A I N C O D E R E Q U I R E D A I R G A P ) E S C U T C H E O N P L A T E C U P F I L L E R - W H I T E H A L L M O D E L W H B F 4 S E M I - R E C E S S E D S E N S O R O P E R A T E D L I G A T U R E R E S I S T A N T C U P F I L L E R W I T H L O C K I N G H I N G E D D O O R , B A T T E R Y O P E R A T E D S E N S O R , W H I T E F I N I S H , 1 / 2 " C O L D W A T E R W I T H S H U T - O F F V A L V E A N D 1 - 1 / 2 " W A S T E L I N E W I T H P - T R A P . 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " - - - C U P I C E M A K E R H O O K - U P - G U Y G R A Y M O D E L B I M 8 7 5 R E C E S S E D W A L L M O U N T E D U T I L I T Y B O X W I T H 1 / 2 " C O L D W A T E R S U P P L Y C O M P L E T E W I T H S H U T - O F F V A L V E . C O O R D I N A T E M O U N T I N G H E I G H T O F B O X W I T H E Q U I P M E N T B E I N G F U R N I S H E D . - - - - - - 1 / 2 " - - - I C E F L O O R S I N K - Z U R N Z - 1 9 0 0 - 2 W I T H 1 / 2 G R A T E , D O M E S T R A I N E R , W H I T E E N A M E L F I N I S H A N D 2 " D E E P S E A L P - T R A P . 2 " 2 " - - - - - - F S - 1 L I G A T U R E S H O W E R S T A L L - M U S T E E D U R A S T A L L M O D E L 1 4 0 F R E E S T A N D I N G S H O W E R S T A L L W I T H C E N T E R D R A I N , W H I T E H A L L W H D G - Z N - 5 R D L I G A T U R E R E S I S T A N T D R A I N G R A T E W I T H 2 " D E E P S E A L P - T R A P , W H I T E H A L L W H S V 1 6 T E M P E R A T U R E / P R E S S U R E C O M P E N S A T I N G S H O W E R V A L V E , A N D W H I T E H A L L W H C S H 2 5 S H O W E R H E A D 2 " 2 " 1 / 2 " 1 / 2 " S H - 2 L I G A T U R E S H O W E R S T A L L - A Q U A T I C M O D E L 1 3 6 3 C O N E - P I E C E M O L D E D S H O W E R S T A L L W I T H C E N T E R D R A I N , W H I T E H A L L W H D G - Z N - 5 R D L I G A T U R E R E S I S T A N T D R A I N G R A T E W I T H 2 " D E E P S E A L P - T R A P , W H I T E H A L L W H S V 1 6 T E M P E R A T U R E / P R E S S U R E C O M P E N S A T I N G S H O W E R V A L V E , A N D W H I T E H A L L W H C S H 2 5 S H O W E R H E A D 2 " 2 " 1 / 2 " 1 / 2 " S H - 3 BOTT O M O F H E A T E R T O BE 3'- 0 " A B O V E F L O O R DRAIN VAL V E TYPICAL U N I O N TYP. SERVICE VALVE P L A N N O T E S : 1 D I S C O N N E C T E X I S T I N G H E A T P U M P F R O M E X I S T I N G D U C T W O R K A N D H Y D R O N I C P I P I N G A N D E L E C T R I C A L W I R I N G . R E M O V E E X I S T I N G H E A T P U M P . R E F E R T O S H E E T M 1 . 1 F O R N E W H E A T P U M P T O B E I N S T A L L E D A N D C O N N E C T E D T O E X I S T I N G P I P I N G A N D D U C T W O R K . C O N T R A C T O R T O F I E L D V E R I F Y A L L S I Z E S A N D L O C A T I O N S O F E X I S T I N G E Q U I P M E N T , P I P I N G A N D D U C T W O R K . D I S C O N N E C T A N D R E M O V E E X I S T I N G B O O S T E R F A N I N D U C T W O R K . R E F E R T O S H E E T M 1 . 1 F O R N E W B O O S T E R F A N T O B E I N S T A L L E D A N D C O N N E C T E D T O E X I S T I N G D U C T W O R K . C O N T R A C T O R T O F I E L D V E R I F Y A L L S I Z E S A N D L O C A T I O N S O F E X I S T I N G E Q U I P M E N T , P I P I N G A N D D U C T W O R K . E X I S T I N G F I N A L F I L T E R S E C T I O N I N D U C T W O R K T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . C O N T R A C T O R T O F I E L D V E R I F Y A L L S I Z E S A N D L O C A T I O N S O F E X I S T I N G E Q U I P M E N T , P I P I N G A N D D U C T W O R K . C O N T R A C T O R T O P R O V I D E N E W F I L T E R M E D I A A T P O I N T O F T U R N - O V E R . A L L E X I S T I N G M A I N T R U N K D U C T W O R K T O R E M A I N U N L E S S N O T E D O T H E R W I S E . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F E X I S T I N G D U C T W O R K . C U T E X I S T I N G M A I N T R U N K D U C T A T T H I S P O I N T . P R O V I D E N E W E N D C A P O N E X I S T I N G D U C T . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N O F E X I S T I N G D U C T W O R K A N D P R O V I D E C A P T O M A T C H E X I S T I N G D U C T . S E A L A I R T I G H T . D I S C O N N E C T A N D R E M O V E E X I S T I N G C E I L I N G D I F F U S E R , R E T U R N A I R G R I L L E A N D / O R E X H A U S T G R I L L E A S I N D I C A T E D . R E M O V E A L L E X I S T I N G B R A N C H D U C T S B A C K T O M A I N T R U N K D U C T . E X I S T I N G B A L A N C I N G D A M P E R T O R E M A I N . R E F E R T O S H E E T M 1 . 1 F O R N E W B R A N C H D U C T S T O B E C O N N E C T E D T O E X I S T I N G T R U N K D U C T W O R K . C O N T R A C T O R T O F I E L D V E R I F Y E X I S T I N G S I Z E S A N D L O C A T I O N O F A L L C E I L I N G G R I L L E S A N D B R A N C H D U C T S . D I S C O N N E C T A N D R E M O V E E X I S T I N G T R A N S F E R G R I L L E S I N E X I S T I N G C E I L I N G . E X I S T I N G D U C T W O R K A B O V E C E I L I N G T O R E M A I N . R E F E R T O S H E E T M 1 . 1 F O R N E W C E I L I N G G R I L L E T O B E I N S T A L L E D A N D C O N N E C T E D T O E X I S T I N G T R A N S F E R D U C T . E X I S T I N G S M O K E / F I R E A N D / O R F I R E D A M P E R I N D U C T W O R K T O R E M A I N U N L E S S D U C T W O R K I S R E M O V E D . M A I N T A I N D A M P E R C O N N E C T I O N S T O F I R E A L A R M S Y S T E M . ( R E F E R T O E L E C T R I C A L D R A W I N G S . ) E X I S T I N G I N - L I N E F A N T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N A N D M A I N T A I N O P E R A T I O N . E X I S T I N G W A L L M O U N T E D R O O M S E N S O R T O R E M A I N . R E M O V E E X I S T I N G S E N S O R F R O M W A L L A N D R E T A I N D U R I N G W A L L C O N S T R U C T I O N . R E F E R T O S H E E T M 1 . 1 F O R N E W S E N S O R L O C A T I O N S A N D C O N N E C T I O N T O N E W H E A T P U M P S . E X I S T I N G E X H A U S T G R I L L E I N C E I L I N G T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . E X I S T I N G D I F F U S E R , D U C T W O R K A N D F I R E D A M P E R T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . E X I S T I N G R E T U R N A I R G R I L L E N E A R F L O O R T O R E M A I N . R E M O V E G R I L L E A S R E Q U I R E D F O R N E W W A L L F I N I S H E S A N D R E P L A C E A F T E R W O R K H A S B E E N C O M P L E T E D . R E M O V E E X I S T I N G R E T U R N A I R G R I L L E N E A R F L O O R . R E M O V E E X I S T I N G D U C T W O R K I N W A L L A N D C A P B E L O W F L O O R . F I E L D V E R I F Y E X I S T I N G C O N D I T I O N S A N D L O C A T I O N A N D S I Z E O F E X I S T I N G D U C T W O R K . R E F E R T O A R C H I T E C T U R A L D R A W I N G S F O R C U T T I N G A N D P A T C H I N G O F E X I S T I N G C O N C R E T E F L O O R S . K E Y P L A N P R O J E C T L O C T I O N 2 3 4 5 6 7 8 9 1 0 T H R E E M 0 . 1 MEC H A N I C A L D E M O L I T I O N P L A N N o r t h SCALE: 3/16 " = 1 ' - 0 " S F S F FD S F F D 6 4 6 4 4 4 4 6 5 6 3 1 2 4 1 4 2 4 1 2 6 6 4 4 4 4 4 4 4 4 6 5 4 4 4 1 7 7 2 3 1 0 9 4 6 6 6 6 1 2 4 4 4 4 8 6 6 4 5 6 3 1 4 6 6 4 4 4 4 4 6 4 6 4 4 8 1 3 6 4 4 6 4 6 4 4 6 4 1 6 6 4 6 4 4 4 1 1 4 6 4 4 4 1 1 2 3 3 2 1 4 4 6 464 4 66 1244664 4 9 4 3 1 2 4 4 4 4 4 64664 6 4 4 4 4 4 1 1 3 3 6 4 4 4 4 6 8 3 6 5 M J E N S E N D S U D W E E K S 7 7 8 S E P T 2 0 2 0 E n g i n e e r e d S y s t e m s A s s o c i a t e s O c t 1 2 , 2 0 2 0 O R I G I N A L D R A W I N G S I G N E D B Y : D W A Y N E C . S U D W E E K S D A T E O R I G I N A L S I G N E D : O R I G I N A L O N F I L E A T E N G I N E E R E D S Y S T E M S A S S O C I A T E S 1 3 5 5 E A S T C E N T E R , P O C A T E L L O , I D A H O 8 3 2 0 1 O c t 1 2 , 2 0 2 0 2 2 6 3 6 3 3 2 2 2 1 1 1 2 1 3 13 1 3 1 3 1 3 1 3 1 4 1 3 1 3 1 3 1 3 131313 1 4 1 3 1 4 1 4 1 3 1 3 1 3 1 4 1 4 S S S S S 1 0 1 0 1 0 1 0 S S 1 0 S 1 0 S 1 0 S S S 1010 1 0 S 10 S 10 P L A N N O T E S : K E Y P L A N P R O J E C T L O C T I O N T H R E E M 1 . 1 MEC H A N I C A L F L O O R P L A N N o r t h SCALE: 3/16 " = 1 ' - 0 " PATIENT RM230 T . R . 2 0 6 O F F I C E 2 1 4 P A T I E N T R M 2 1 7 P A T I E N T R M 2 2 0 P A T I E N T R M 2 3 3 V E S T 2 0 2 S E C L U S I O N 2 0 7 E X A M 2 1 5 C O R R I D O R 2 1 6 VEST222T.R.231 R E C ' P 2 0 1 S T A F F P A T I O 2 0 5 N U R S E 2 4 0 T.R.224 PATIENT RM223 C O R R I D O R 2 3 6 M E D I A 2 3 5 V I S I T I N G 2 0 3 N U R S E W O R K R O O M 2 3 7 T.R.225 PATIENT RM226 CORRIDOR 209 S T O R A G E 2 3 4 O F F I C E 2 0 4 M E D S 2 3 8 T.R.228 PATIENT RM229 T E A M R M 2 4 2 T . R . 2 3 2 E X I S T C O R R 2 0 0 N U R S E 2 3 9 S T A F F 2 4 1 E V S 2 4 3 G R O U P T H E R A P Y 2 1 1 D A Y R M 2 1 0 O B S E R V A T I O N 2 0 8 T H E R A P Y 2 1 3 T . R . 2 1 8 T . R . 2 1 9 M J E N S E N D S U D W E E K S 7 7 8 S E P T 2 0 2 0 E n g i n e e r e d S y s t e m s A s s o c i a t e s O c t 1 2 , 2 0 2 0 O R I G I N A L D R A W I N G S I G N E D B Y : D W A Y N E C . S U D W E E K S D A T E O R I G I N A L S I G N E D : O R I G I N A L O N F I L E A T E N G I N E E R E D S Y S T E M S A S S O C I A T E S 1 3 5 5 E A S T C E N T E R , P O C A T E L L O , I D A H O 8 3 2 0 1 O c t 1 2 , 2 0 2 0 1 P R O V I D E N E W W A T E R S O U R C E H E A T P U M P A S S P E C I F I E D . P R O V I D E N E W T R A N S I T I O N S A S R E Q U I R E D T O C O N N E C T T O E X I S T I N G M A K E - U P A I R A N D S U P P L Y A I R D U C T W O R K . P R O V I D E N E W H O S E K I T S T O C O N N E C T T O E X I S T I N G H Y D R O N I C P I P I N G . C O N N E C T N E W U N I T T O E X I S T I N G C O N D E N S A T E D R A I N L I N E . P R O V I D E S H E E T M E T A L D R A I N P A N B E L O W U N I T W I T H D R A I N . M O U N T U N I T S H I G H E N O U G H T O C O N N E C T T O E X I S T I N G C O N D E N S A T E D R A I N L I N E . R E F E R T O E L E C T R I C A L D R A W I N G S F O R P O W E R W I R I N G . C O N T R A C T O R T O F I E L D V E R I F Y A L L S I Z E S A N D L O C A T I O N S O F E X I S T I N G E Q U I P M E N T , P I P I N G A N D D U C T W O R K . P R O V I D E N E W I N - L I N E B O O S T E R F A N A S S P E C I F I E D . P R O V I D E N E W D U C T T R A N S I T I O N S A S R E Q U I R E D T O C O N N E C T T O N E W H E A T P U M P A N D T O E X I S T I N G D U C T W O R K . C O N T R A C T O R T O F I E L D V E R I F Y A L L S I Z E S A N D L O C A T I O N S O F E X I S T I N G E Q U I P M E N T , P I P I N G A N D D U C T W O R K . E X I S T I N G F I N A L F I L T E R S E C T I O N I N D U C T W O R K T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . C O N T R A C T O R T O F I E L D V E R I F Y A L L S I Z E S A N D L O C A T I O N S O F E X I S T I N G E Q U I P M E N T , P I P I N G A N D D U C T W O R K . C O N T R A C T O R T O P R O V I D E N E W F I L T E R M E D I A A T P O I N T O F T U R N - O V E R . A L L E X I S T I N G M A I N T R U N K D U C T W O R K T O R E M A I N U N L E S S N O T E D O T H E R W I S E . C O N T R A C T O R T O F I E L D V E R I F Y E X A C T S I Z E S A N D L O C A T I O N S O F E X I S T I N G D U C T W O R K . P R O V I D E N E W C E I L I N G G R I L L E A N D N E W B R A N C H D U C T A S I N D I C A T E D I N G R I L L E A N D R E G I S T E R S C H E D U L E . C O N N E C T N E W B R A N C H D U C T T O E X I S T I N G T R U N K D U C T . P R O V I D E M A N U A L B A L A N C I N G D A M P E R A B O V E L A Y - I N C E I L I N G A N D B A L A N C E T O C F M A S I N D I C A T E D . P R O V I D E N E W C E I L I N G G R I L L E A N D N E W B R A N C H D U C T A S I N D I C A T E D I N G R I L L E A N D R E G I S T E R S C H E D U L E . C O N N E C T N E W B R A N C H D U C T T O E X I S T I N G T A K E - O F F . P R O V I D E D U C T T R A N S I T I O N A S R E Q U I R E D F O R C O N N E C T I O N . P R O V I D E M A N U A L B A L A N C I N G D A M P E R W I T H R E M O T E C O N T R O L . C O V E R R E M O T E C O N T R O L W I T H P L A T E A N D F A S T E N W I T H S E C U R I T Y S C R E W S . E X I S T I N G R E T U R N A I R G R I L L E N E A R F L O O R T O R E M A I N . R E M O V E G R I L L E A S R E Q U I R E D F O R N E W W A L L F I N I S H E S A N D R E P L A C E A F T E R W O R K H A S B E E N C O M P L E T E D . C A U L K E X I S T I N G G R I L L E T O W A L L A N D F A S T E N W I T H N E W S E C U R I T Y S C R E W S . E X I S T I N G I N - L I N E R E T U R N F A N T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N A N D M A I N T A I N O P E R A T I O N . E X I S T I N G E X H A U S T G R I L L E I N C E I L I N G T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . E X I S T I N G D I F F U S E R , D U C T W O R K A N D F I R E D A M P E R T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . R E L O C A T E E X I S T I N G R O O M S E N S O R T O L O C A T I O N A S S H O W N . ( R E F E R T O S H E E T M 0 1 . F O R E X I S T I N G L O C A T I O N S . ) P R O V I D E N E W S E C U R I N G H O S P I T A L S M O D E L 8 1 2 - S 4 2 - S R L O C K I N G L I G A T U R E R E S I S T A N T T H E R M O S T A T C O V E R O V E R A L L S E N S O R S . 2 3 4 5 6 7 8 9 1 0 FD 6 4 4 4 4 4 3 1 2 4 1 4 2 4 1 2 4 4 4 4 4 4 4 4 5 4 4 4 1 2 3 8 4 5 1 4 4 4 6 3 1 4 4 4 4 4 4 5 4 4 1 3 4 4 5 4 5 4 4 4 1 4 4 4 4 4 5 4 4 4 1 1 23 3 2 1 4 4 744 4 66 104464 4 8 4 3 2 4 4 4 4 44 4 4 4 4 4 4 1 1 3 3 4 4 4 4 5 3 2 2 3 3 3 2 2 2 C D - 2 2 5 0 C D - 3 1 0 0 1 H P 1 B F E R - 1 1 5 0 E R - 1 1 5 0 6 6 6 2 H P 2 B F C D - 2 2 5 0 6 H D H D C D - 3 1 0 0 6 R G - 3 C D - 1 1 0 0 3 B F 3 H P C D - 1 1 5 0 5 H D C D - 1 1 5 0 5 5 C D - 1 2 0 0 5 C D - 1 2 0 0 1 4 H P 1 4 B F 7 7 7777 7 7 7 7 7 7 2 4 B F 4 H P C D - 1 3 0 0 6 C D - 1 3 0 0 5 7 C D - 2 1 5 0 C D - 3 1 0 0 C D - 3 1 0 0 C D - 1 1 0 0 C D - 1 1 0 0 C D - 1 2 0 0 E R - 1 1 5 0 6 6 5 B F 5 H P 6 H P C D - 1 2 0 0 5 E R - 2 2 0 0 5 5 150 CFMCD-23006CD-3100ER-1150ER-1150 66CD-3100CD-23006 11 HP 1 1 B F 1 0 H P 1 0 B F 1 CD-2300CD-3100 ER-11506 9 B F 9 H P CD-23006ER-11506 CD-3100 6 E R - 1 1 5 0 6 C D - 3 1 0 0 6 8 H P 8 B F C D - 2 3 0 0 C D - 1 1 0 0 C D - 1 1 0 0 5 5 7 B F 7 H P 7 E R - 1 1 5 0 C D - 1 1 0 0 C D - 1 2 0 0 C D - 3 1 0 0 C D - 1 3 0 0 C D - 1 2 0 0 C D - 1 1 5 0 C D - 1 2 5 0 C D - 1 2 5 0 C D - 1 2 5 0 5 5 5 1 2 H P 1 2 B F 5 1 3 B F 1 3 H P 6 5 9 H D H D H D H D H D H D H D H D H D C H D C H D C H D CHDCHD 6 CHD TYP. 10"Ø CHD CHDCHD CHDCHD CHDCHDTYP. 8"Ø TYP. 10"Ø TYP. 8"ØCHD CHD CHDSHP-11 11SHP-1011SHP-9 11SHP-811 S 1 1 H P - 7 S H P - 6 1 1 H D H D H D H D H D H D H D H D T Y P . 1 0 " Ø T Y P . 1 0 " Ø 7 T Y P . 1 0 " Ø C H D C H D C H D 5 T Y P . 1 0 " Ø C D - 3 1 0 0 5 H D H D H D T Y P . 1 0 " Ø 8 x 6 E A S 1 1 H P - 5 S H P - 4 1 1 S H P - 1 4 1 1 C O N N E C T N E W 1 0 x 1 0 E X H A U S T D U C T T O E X I S T I N G 1 0 x 1 0 D U C T A T T H I S P O I N T . T Y P . 1 0 " Ø H D H D S 1 1 H P - 1 C H D C H D C H D C H D C H D T Y P . 1 0 " Ø C H D 8 " Ø H D S H P - 2 1 1 S H P - 3 1 1 1 1 T H R E E M 3 . 1 S.P.E.1 BF SYM.TYPEIN-LINE C.F.M.350 BOOSTER FAN SCHEDULECONTROLCHAR.WATTS5470.5"120/60/1 R.P.M.1680 R E M A R K S KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L H E A T I N G W A T E R S O U R C E H E A T P U M P S C H E D U L E L A T S Y M . T Y P E O A C . F . M . C H A R . S . P . E . B T U E A T C O O L I N G L A T L W T C O P E W T B T U E A T L W T E E R E W T P I P E S I Z E G P M P D R E M A R K S M C A W E I G H T 1 H P 9 9 ° F 3 5 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 1 4 , 7 0 0 6 5 ° F 5 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H R I G H T R E T U R N A N D B A C K D I S C H A R G E 1 5 0 # 4 . 3 T H R O W C D - 1 S Y M . S I Z E G R I L L E A N D R E G I S T E R S C H E D U L E B R A N C H C O N S T R . C F M F I N I S H D U C T F . D . O . B . R E M A R K S 1 2 x 1 2 5 0 - 4 0 0 S T E E L W H I T E 1 0 " Ø N O N O P R I C E S M D I N 2 4 x 2 4 L A Y - I N M O D U L E E R - 1 8 x 8 - - - 5 0 - 2 0 0 S T E E L W H I T E N O Y E S M C O P 1 5 INTERLOCKWITH HP-1 FAN SIZE10" Ø 2 H P 9 9 ° F 3 5 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 5 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E 1 5 0 # 4 . 3 1 5 2 BFIN-LINE3505470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-210" Ø C D - 2 1 2 x 1 2 5 0 - 4 0 0 S T E E L W H I T E 1 0 " Ø N O N O P R I C E M S P G W I T H 4 - S I D E D M O U N T I N G F R A M E C D - 3 8 x 8 5 0 - 2 0 0 S T E E L W H I T E 8 " Ø N O N O 8 x 6 3 H P 9 9 ° F 4 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 4 . 3 1 5 5 5 ° F 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " 1 5 0 # C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H R I G H T R E T U R N A N D B A C K D I S C H A R G E 3 BFIN-LINE4005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-310" Ø 4 H P 5 H P 6 H P 7 H P 8 H P 9 H P 1 0 H P 1 1 H P 1 2 H P 1 3 H P 1 4 H P 4 BF5BF6BF7BF8BF9BF10BF11BF12BF13BF14BFIN-LINE4005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-1410" Ø 9 9 ° F 4 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 H O R I Z O N T A L H I G H S T A T I C U N I T 4 . 3 1 5 5 5 ° F 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " 1 5 0 # C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E 9 9 ° F 6 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 1 0 . 5 2 1 , 8 0 0 6 5 ° F 5 . 0 1 5 6 0 ° F 5 0 ° F 1 8 , 7 0 0 5 5 ° F 7 5 ° F 1 4 . 0 8 0 ° F 9 0 ° F 7 . 0 ' 3 . 3 8 1 / 2 " 2 0 0 # C L I M A T E M A S T E R M O D E L T C H 0 1 8 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E IN-LINE6005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-410" Ø 5 5 ° F 1 1 , 1 0 0 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E 1 5 0 # 9 9 ° F 3 5 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 6 0 ° F 5 0 ° F 4 . 3 1 5 H I G H S T A T I C U N I T H O R I Z O N T A L H I G H S T A T I C U N I T H O R I Z O N T A L H I G H S T A T I C U N I T H O R I Z O N T A L H I G H S T A T I C U N I T H O R I Z O N T A L H I G H S T A T I C U N I T H O R I Z O N T A L 9 9 ° F 6 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 1 0 . 5 6 5 ° F 5 . 0 1 5 6 0 ° F 5 0 ° F 1 8 , 7 0 0 5 5 ° F 7 5 ° F 1 4 . 0 H I G H S T A T I C U N I T H O R I Z O N T A L 8 0 ° F 9 0 ° F 7 . 0 ' 3 . 3 8 1 / 2 " 2 0 0 # C L I M A T E M A S T E R M O D E L T C H 0 1 8 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E C L I M A T E M A S T E R M O D E L T C H 0 1 5 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E 9 9 ° F 4 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 4 . 3 1 5 5 5 ° F 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " 1 5 0 # H I G H S T A T I C U N I T H O R I Z O N T A L 9 9 ° F 5 5 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 8 . 7 1 7 , 1 0 0 6 5 ° F 6 0 ° F 5 0 ° F 1 4 , 3 0 0 5 . 0 1 5 5 5 ° F 7 5 ° F 1 4 . 5 8 0 ° F 9 0 ° F 2 . 5 ' 2 . 8 1 1 / 2 " 2 0 0 # H I G H S T A T I C U N I T H O R I Z O N T A L IN-LINE3505470.5"120/60/11680INTERLOCKWITH HP-210" ØNOT USED KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L IN-LINE5255470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-1110" Ø IN-LINE4005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-1010" Ø 9 9 ° F 4 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 4 . 3 1 5 5 5 ° F 7 5 ° F 1 2 . 5 H I G H S T A T I C U N I T H O R I Z O N T A L 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " 1 5 0 # C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H R I G H T R E T U R N A N D B A C K D I S C H A R G E C L I M A T E M A S T E R M O D E L T C H 0 1 8 A G W I T H R I G H T R E T U R N A N D B A C K D I S C H A R G E H I G H S T A T I C U N I T H O R I Z O N T A L 9 9 ° F 4 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 7 . 3 6 5 ° F 6 0 ° F 5 0 ° F 1 1 , 1 0 0 4 . 3 1 5 H I G H S T A T I C U N I T H O R I Z O N T A L 5 5 ° F 7 5 ° F 1 2 . 5 8 0 ° F 9 0 ° F 2 . 3 ' 2 . 2 5 1 / 2 " 1 5 0 # C L I M A T E M A S T E R M O D E L T C H 0 1 2 A G W I T H L E F T R E T U R N A N D B A C K D I S C H A R G E IN-LINE4005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-910" Ø IN-LINE4005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-810" Ø IN-LINE5005470.5"120/60/11680KANALFLAKT FKD - 1 0 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-710" Ø 9 9 ° F 9 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 2 0 . 6 3 7 , 0 0 0 6 5 ° F 6 0 ° F 5 0 ° F 2 8 , 6 0 0 4 . 7 3 0 7 5 ° F H I G H S T A T I C U N I T H O R I Z O N T A L 5 5 ° F 1 3 . 0 8 0 ° F 9 0 ° F 3 . 9 ' 5 . 6 3 3 / 4 " 2 0 0 # C L I M A T E M A S T E R M O D E L T C H 0 3 0 A G W I T H R I G H T R E T U R N A N D B A C K D I S C H A R G E 9 9 ° F 9 0 0 5 0 0 . 4 5 " 2 0 8 - 2 3 0 / 6 0 / 1 2 0 . 6 6 5 ° F 6 0 ° F 5 0 ° F 2 8 , 6 0 0 4 . 7 3 0 7 5 ° F H I G H S T A T I C U N I T H O R I Z O N T A L 5 5 ° F 1 3 . 0 8 0 ° F 9 0 ° F 3 . 9 ' 5 . 6 3 3 / 4 " 2 0 0 # C L I M A T E M A S T E R M O D E L T C H 0 3 0 A G W I T H R I G H T R E T U R N A N D B A C K D I S C H A R G E IN-LINE9005470.5"120/60/11680KANALFLAKT FKD - 1 2 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-1312" Ø IN-LINE9005470.5"120/60/11680KANALFLAKT FKD - 1 2 X L . P R O V I D E 1 5 2 0 C T T R A N S F O R M E R F O R 1 0 0 % VARIABLE SPEED C O N T R O L W I T H 0 - 1 0 V O L T S I G N A L INTERLOCKWITH HP-1212" ØCEILING DIFFUSER DETAIL WITH FLEXIBLE DUCTNO SCALE DUCTSUPPORT 1" ACOUSTICAL DUCT LINER ON INTERIOR OF DUCT.24" MAX TO FIRST SUPPORTRIGID SPIN- IN FITTINGHAND DAMPERHANDLEROUND RIGID DUCT.WING NUTRECTANGULAR SUPPLY DUCT GLUE FLEX DUCT TO FITTING, CLAMP DOWN WITH STRAP AND SCREW SOLID TO RIGID FITTINGATTACH TO RIGID DUCTWITH DRAW BANDOPPOSED BLADE DAMPER WHERE SPECIFIEDLAY-IN DIFFUSERLAY-IN CEILING ROUND TO SQUARE TRANSITION GLUE FLEX DUCT T O ADAPTER & CLAMP DOWN WITH STRAP . ROUND FLEXIBLE SUPPLY DUCT TO CEILING DIFFUSER 8'-0" MAX. LENGTH 24" MAX TO FIRST SUPPORTDUCT SUPPORT EXTERNAL DUCT INSULATION ON ALL ROUND RIGID DUCT- WORK AND FITTINGS. D A M P E R S U P P O R T D U C T D A M P E R R E M O T E C O N T R O L S U P P L Y D U C T R E C T A N G U L A R R O U N D R I G I D D U C T . S C R E W S O L I D T O R I G I D F I T T I N G C L A M P D O W N W I T H S T R A P A N D G L U E F L E X D U C T T O F I T T I N G , B A N D A T T A C H T O R I G I D D U C T W I T H D R A W S P E C I F I E D D A M P E R W H E R E O P P O S E D B L A D E T R A N S I T I O N S Q U A R E R O U N D T O D O W N W I T H S T R A P . A D A P T E R & C L A M P G L U E F L E X D U C T T O 8 ' - 0 " M A X . L E N G T H D U C T T O C E I L I N G D I F F U S E R R O U N D F L E X I B L E S U P P L Y F I R S T S U P P O R T 2 4 " M A X T O D U C T S U P P O R T D U C T - W O R K A N D F I T T I N G S . O N A L L R O U N D R I G I D E X T E R N A L D U C T I N S U L A T I O N I N F I T T I N G R I G I D S P I N - F I R S T S U P P O R T 2 4 " M A X T O O F D U C T . L I N E R O N I N T E R I O R 1 " A C O U S T I C A L D U C T C E I L I N G N O S C A L E C E I L I N G D I F F U S E R D E T A I L W I T H F L E X I B L E D U C T REINFORCINGDUCT CONSTRUCTION AND HANGER DETAI L MENDEDGAGE2426 DRIVERECOM-SLIPNO SCALE 19 - 30 13 - 18 UP THRU 12 LONGESTINCHESSIDE,DIMENSIONNONE REQUIRED26NONE REQUIRED1"x1"x1/8" @ 60 IN24 24 (ALLFOURSIDES)OFGAGEMETAL SHEETBETWEENINTERMEDIATEREINFORCINGJOINTS &/OR TRANSVERSE ANGLE SIZESPACINGLONGITUDINALAND MAXIMUM2"2"26MAX.12" OC 2424-S SLIPRECOM-MENDEDGAGE HEMMED1"TRANSVERSE REINFORCING (1)MINIMUMAT JOINTS(1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED.GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL AIR HAMMER OR BY AUTOMATIC FASTENER EQUIP.METAL FASTENERS - OMARK INSULPINS,DURO DYNE FASTENERS OR GRIPNAILS.STRAPS TO BE TIGHT AGAINST DUCTWORK HANG DUCTS UP TO 30" WIDTH WITH 1" x 18 GAGE STRAPS AT 10'-0" MAXIMUM SPACING.SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREWNO P O P R I V E T S A L L O W E D HANGE R S T R A P S SHEET METAL DUCT NOT MORE THAN 2" FROM EDGE OF LINERALL ENDS OF LINER TO BE COATED WITH ADHESIVE. SEE SPECIFICATIONS.1" THICK DUCT LINER TOP AND BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDESENDS OF LINER SHALL BE BUTTED FIRMLY TOGETHER LINE R T O B E A D H E R E D T O DUCT W / 1 0 0 % A D H E S I V E SEE S P E C I F I C A T I O N S . F L E X I B L E D U C T S U P P O R T D E T A I L N O S C A L E 2 ' - 0 " M A X I M U M F O O T O F S U P P O R T S P A C I N G . M A X . S A G 1 / 2 " P E R B A N D C L A M P 1 " x 1 8 G A G E S E C U R E T O S T R U C T U R E . P R I C E M S P G W I T H 4 - S I D E D M O U N T I N G F R A M E P R I C E M S P G W I T H 4 - S I D E D M O U N T I N G F R A M E E R - 2 1 0 x 1 0 - - - 5 0 - 2 0 0 S T E E L W H I T E N O N O 1 0 x 8 P R I C E 5 3 5 I N 2 4 x 2 4 L A Y - I N M O D U L E M J E N S E N D S U D W E E K S 7 7 8 S E P T 2 0 2 0 E n g i n e e r e d S y s t e m s A s s o c i a t e s O c t 1 2 , 2 0 2 0 O R I G I N A L D R A W I N G S I G N E D B Y : D W A Y N E C . S U D W E E K S D A T E O R I G I N A L S I G N E D : O R I G I N A L O N F I L E A T E N G I N E E R E D S Y S T E M S A S S O C I A T E S 1 3 5 5 E A S T C E N T E R , P O C A T E L L O , I D A H O 8 3 2 0 1 O c t 1 2 , 2 0 2 0 F A S T E N C O V E R P L A T E W I T H S E C U R I T Y S C R E W S . 1 8 , 0 0 5 5 ° F 7 5 ° F 1 4 . 0 8 0 ° F 9 0 ° F 7 . 0 ' 3 . 3 8 1 / 2 " 2 0 0 # 9 9 ° F 2 0 8 - 2 3 0 / 6 0 / 1 1 0 . 5 6 5 ° F 5 . 0 1 5 6 0 ° F 5 0 ° F 6 0 0 5 0 0 . 4 5 " 3 7 , 0 0 0 1 4 , 7 0 0 1 4 , 7 0 0 1 4 , 7 0 0 1 4 , 7 0 0 1 4 , 7 0 0 1 4 , 7 0 0 1 4 , 7 0 0 2 1 , 8 0 0 2 1 , 8 0 0 H E A T P U M P P I P I N G A N D S U P P O R T D E T A I L N O S C A L E C O N N E C T R O D T H R U C L I P A N D U N I T F U R N I S H E D R U B B E R V I B R A T I O N I S O L A T O R S 3 / 8 " D I A . R O D T Y P . F O R E A C H C O R N E R H Y D R O N I C U N I T T Y P . E L E C T R O - S U P P L Y A I R ( T Y P I C A L O F A L L U N I T S ) P I T C H A W A Y F R O M U N I T 3 / 4 " C O N D E N S A T E D R A I N C O N N E C T I O N F L E X I B L E O F E A C H U N I T J O I S T S B R A C I N G A S A N C H O R R O D S T O R O O F R E Q ' D - A D J U S T H E I G H T A S N E C E S S A R Y R E T U R N A I R R E T U R N P I P I N G E X I S T I N G H E A T P U M P E X I S T I N G H E A T P U M P F L E X I B L E H O S E W / P I P E F I T T I N G S C O N N E C T I O N S I Z E V A R I E S W / U N I T . S E E S C H E D U L E E X I S T I N G U N I O N ( T Y P ) S U P P L Y P I P I N G T R A P W I T H V E N T . T Y P I C A L O F A L L U N I T S . V E N T D E T A I L 2 " 1 " 3 " C O N T R O L D E V I C E E X I S T I N G A U T O M A T I C F L O W E X I S T I N G S T R A I N E R D R A I N P A N N O T E : V E R T I C A L H E A T P U M P S A R E P I P E D S I M I L A R . P R O V I D E S H E E T M E T A L D R A I N P A N B E L O W A L L H O R I Z O N T A L A N D V E R T I C A L U N I T S . E X I S T I N G S H U T - O F F V A L V E T O R E M A I N E X I S T I N G C O N T R O L V A L V E T O R E M A I N LOCKERS TABLETABLE TABLETABLE LOCKERS C DCD D VITA L S FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL TWIN ICE MAC H I N E FULL SERV I N G WIND O W COM P U T E R COM P U T E R LOCKINGSTORAGECABINET LOCKINGSTORAGECABINET DN F.D. F.D.F.D. 12"x2" 12 " x 2 " 1 1 1 'EH4' 'E4''A' 'EH5' 'M' 'M1' 'EM2' 'EM1' 'EM3' 'MH' 'MH1' 2 2 3 EXISTING SERVER/IT ROOM PROVIDE ADDITIONAL PATCH PANELS AS REQUIRED FOR NEW DATA CABLING. CIRCUITING & GENERAL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION KEYED NOTE REFERENCE1 BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED A-1,3,5 3/4"C.-6#12,1#12G QTY & SIZE OF EQUIPMENT GROUND CONDUCTORQTY & SIZE OF NEUTRAL AND PHASE CONDUCTOR(S)SIZE OF CONDUIT A-1,3,5 3/4"C.-6#12,1#12G PANEL AND CIRCUIT DESIGNATIONS EQUIPMENT GROUNDING CONDUCTOR TICK MARKS NEUTRAL CONDUCTOR(S) PHASE AND/OR SWITCH-LEG CONDUCTOR(S) BRANCH CIRCUIT/FEEDER CONCEALED IN CEILING OR WALL BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR NEW EQUIPMENT, DEVICES, ETC. EXISTING EQUIPMENT, DEVICES, ETC. DEMOLITION EQUIPMENT, DEVICES, ETC. DETAIL # / SHEET REFERENCE1 / ES101 *25,000A CALCULATED AVAILABLE FAULT CURRENT AT EQUIPMENT(SEE POWER RISER) LIGHTING SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PARKING AREA POLE LIGHT, SINGLE OR DOUBLE HEAD AS INDICATED ON DRAWINGS. REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION. 2X4 FLUORESCENT OR LED FIXTURE 2X2 FLUORESCENT OR LED FIXTURE SURFACE MOUNTED FLUORESCENT OR LED FIXTURE STRIP FLUORESCENT OR LED FIXTURE WALL MOUNTED FLUORESCENT OR LED FIXTURE EXTERIOR WALL MOUNTED FIXTURE ROUND RECESSED FIXTURE SURFACE OR PENDANT FIXTURE LIGHT FIXTURE SUBSCRIPTS NL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT) EXIT SIGN, WALL OR CEILING MOUNTING AS REQUIRED (SINGLE OR DOUBLE FACE) DIRECTIONAL CHEVRONS AS INDICATED; CONNECT TO NEAREST "LIFE SAFETY" CIRCUIT IN AREA, FIELD VERIFY. SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. CONNECT TO EMERGENCY POWER SYSTEM AS INDICATED ON DRAWINGS. CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION. SWITCH MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE SWITCHPOD OR DIMMER SWITCH, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND ADDITIONAL INFORMATION. SINGLE-POLE SWITCH (SEE SUB-SCRIPTS BELOW FOR ADDITIONAL INFORMATION) SWITCH SUBSCRIPTS 3 3-WAY SWITCH 4 4-WAY SWITCH D DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES) K KEYED SWITCH F TIMER SWITCH (INTERMATIC MODEL EI400 SERIES) P PILOT LIGHTED SWITCH F1 LIGHT FIXTURE TYPE DESIGNATION S ### WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EMERGENCY LIGHT. LV LOW-VOLTAGE SWITCH (PER DWG'S) T THERMAL-OVERLOAD SWITCH M SWITCH SUPPLIED WITH EQUIPMENT, INSTALLED BY E.C. WP WEATHERPROOF 2P DOUBLE POLE, SINGLE THROW SWITCH GENERAL LIGHTING NOTES: A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING, MOUNTING AND ETC. B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND FIXTURES. D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA. ### F M POWER SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION ELECTRICAL SWITCHBOARD EQUIPMENT, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) 'MSB' 'T##'DRY-TYPE TRANSFORMER, (SEE POWER RISER FOR ADDITIONAL INFORMATION) 'LA' ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R (30A FUSES) COMBINATION STARTER & FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED. TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X J JUNCTION BOX CR = CORD REEL; SEE DRAWINGS FOR INFORMATION CD = CORD DROP; SEE DRAWINGS FOR INFORMATION EQUIPMENT CONNECTION; COORDINATE CONNECTION WITH EQUIPMENT PRIOR TO ROUGH-IN MOTOR CONNECTION POWER AND/OR DATA SERVICE POLE FLOORBOX WITH POWER ONLY (SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) PUSHBUTTON STATION FLOORBOX WITH POWER AND DATA(SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) FB# FB# SPECIAL RECEPTACLE (COORDINATE NEMA TYPE WITH EQUIP.) (REFER TO PANEL SCHEDULES FOR AMPS) CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH CEILING EQUIPMENT PRIOR TO ROUGH-IN) DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT. RECEPTACLE AND EQUIPMENT SUBSCRIPTS AC ABOVE COUNTER WP WEATHERPROOF (UL LISTED WEATHER-RESISTANT) 42"MOUNTING HEIGHT AFF OR AFG IG ISOLATED GROUND S SURGE-PROTECTION TYPE REF REFRIGERATOR W WASHING MACHINE D DRYER (30A-240V RATED RECPT.) M MICROWAVE HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND NUMBER OF CONDUCTORS WITH M.C. T SOR 30A/3P/3R SIZE 1(30A FUSES) SMALL EXHAUST FAN CONNECTION TV 120V RECEPT. FOR TV; VERIFY HEIGHT WITH ARCH. DRAWINGS & ELEVATIONS USB 120V RECPT. WITH USB CHARGING PORTS EWC ELECTRIC WATER COOLER; (SEE DETAIL. RECPT. SHALL BE ACCESSIBLE, DO NOT MOUNT BEHIND HOUSING.) DISP GARBAGE DISP. (UNDER SINK) DW DISHWASHER (COORDINATE W/ MILLWORK, INSTALL PER NEC 422.16(B)(2)). M/R MICROWAVE/RANGE HOOD (COORDINATE W/ MILLWORK) R ELECTRIC RANGE (50A-240V RATED RECPT.) GENERAL SPECIAL SYSTEM NOTES: A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC. SPECIAL SYSTEMS SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-X TELEPHONE OUTLET; _= # OF TELEPHONE CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T-X TELEPHONE/DATA OUTLET; _= # OF TELEPHONE/DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_T/_D-X CEILING MOUNTED DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _D-X A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG. B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN 10X THE DIAMETER OF THE CONDUIT. C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS. D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90'S WITHOUT A PULLBOX. PULL BOXES SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN LENGTH AND MIN, 4" DEEP AND 8" WIDE. E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS INCLUDES SERVICE LOOPS AND PATCH CORDS. F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CONDUITS ENDING AT THE CABLE TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY. GENERAL SPECIAL SYSTEM NOTES: RECESSED IN-WALL AV/TV ENCLOSURE, (SEE NOTE 2 BELOW) 2-GANG: HUBBELL# NSAV62M / NSAV6C 4-GANG: HUBBELL# NSAB124M / NSAV12C (1) POWERKIT HBL#NSOKPS & (1) DATA PLATE W. TERMINATIONS. MOUNT 5'-0" AFF, FIELD COORDINATE WITH TV LOCATION PRIOR TO ROUGH-IN. INSTALL 1 1/4"C FROM ENCLOSURE TO NEAREST ACCESSIBLE CEILING SPACE W/ DATA CABLING/TERMINATIONS AS INDICATED ON DRAWINGS. INSTALL 1 1/4"C FROM ENCLOSURE TO FLOORBOX IN ROOM WHERE INDICATED ON DWG'S. LARGE CAPACITY 3-GANG AV BOX W/ RECEPTACLE, (SEE NOTE 2 BELOW) HUBBELL# HBL263 WITH 3-GANG MUDRING & LV DIVIDER HBL981; PROVIDE 3-GANG DECORA COVER PLATE WITH THE FOLLOWING: (1) 20A DUPLEX RECEPTACLE (1) DATA INSERT (LEVITON P/N: 4164x-xxx) OR EQUAL (1) BRUSH PASSTHROUGH INSERT (LEVITON P/N: 41075-DBx). INSTALL 1 1/2" CONDUIT FROM BOX TO ABOVE ACCESSIBLE CEILING W/DATA CABLING/ TERMINATIONS AS INDICATED ON DRAWINGS. TV# AV _D-X _D-X SPECIAL SYSTEMS NOTES: 1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. UTILIZE J-HOOKS 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT INSTALLED/SPECIFIED. 2. CONDUIT SIZE ('X' FROM ABOVE); 2=1/2", 3=3/4", 4=1", 5=1-1/4", 6=1-1/2" 3. BLANK (NO LABEL) = 4-11/16" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING/CABLE TRAY, TERMINATE WITH INSULATED THROAT BUSHING, PROVIDE PULL STRING. (UNLESS OTHERWISE NOTED) WALL PATHWAY SYSTEM; STI FIRESTOP EZ-PATH SERIES INSTALL THROUGH WALL ABOVE ACCESSIBLE CEILING, FIELD VERIFY EXACT LOCATION TO AVOID CONFLICT WITH OTHER TRADES AND UTILITIES. PROVIDE ALL REQUIRE MOUNTING HARDWARE AND ETC. FOR COMPLETE INSTALLATION. EPF2 = FIRE RATED, EZ-PATH SERIES 22 EPF3 = FIRE RATED, EZ-PATH SERIES 33 EPF4 = FIRE RATED, EZ-PATH SERIES 44 EP3 = NON-FIRE RATED, EZ-PATH 33NEZ SERIES ### FB#_D-X MULTI-SERVICE FLOORBOX; SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION. _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) TV2 = 2-GANG TV4 = 4-GANG A. E.C. SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. B. E.C. SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS. SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL. C. INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. E. E.C. SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT. F. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN. G. LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC. H. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. I. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED FEES. J. MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS. K. UNLESS SPECIFICALLY INDICATED OTHERWISE, E.C. SHALL COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER/SHOP DRAWINGS; DENTAL, MEDICAL, KITCHEN, SPECIALIZED EQUIPMENT, ETC. FOR THE EXACT ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE E.C. TO BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. L. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. M. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. N. DATA CABLING SYSTEM PRE-INSTALLATION CONFERENCE: 1. E.C. SHALL SCHEDULE A MEETING A MINIMUM OF FIVE CALENDAR DAYS PRIOR TO BEGINNING DATA CABLING INSTALLATION . ATTENDEES SHOULD INCLUDE OWNER’S REP., ENGINEER, GC, EC AND CABLING SUB. REFER TO SECTION 26 6210(1.4)(E) FOR ADDITIONAL INFORMATION. PROJECT GENERAL NOTES: ROCKY MOUNTAIN POWER CO. WWW.ROCKYMOUNTAINPOWER.NET CONTACT: DAN KUHL (503) 308-0233 dan.kuhl@evergreen-efficiency.com UTILITY LIGHTING REBATES & INCENTIVES: IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. VISIT THE FOLLOWING UTILITY CO. WEBSITES FOR INFORMATION: TYPICAL DEVICE MOUNTING HEIGHTS: GENERAL COORDINATION NOTE: GENERAL DETAIL NOTES: FINISH FLOOR 1' - 6'' THERMOSTAT OR SENSORVERIFY WITH M.C. PRIOR TO LIGHT SW. (OR AS NOTED) * 4' - 0'' * 3' - 6'' (OR AS NOTED) RECEPTACLE@ MILLWORK BACKSPLASH CA B . D I M E N S I O N S PE R A R C H . D E T A I L 6" CABINET *E.C. SHALL COORDINATE ALL DEVICE MOUNTING HGTS. AND EXACT LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS REPORT CONFLICTS TO ARCHITECT **PRIOR TO ROUGH-IN** ROUGH-IN. TYPICAL FOR ALL DEVICES MOUNTED ABOVE COUNTER (ie C.O.'S, DATA, PHONE etc.) A. B. C. D. ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. ALL SWITCHES AND THERMOSTATS TO BE MOUNTED AS CLOSE TO DOOR JAMS AS POSSIBLE. COORDINATE ALL DEVICES WITH ARCHITECTURAL PLANS AND DETAILS. COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINSCOTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. FIRE 6' - 8'' FIRE ALARM NOTIFICATION DEVICE FIRE MANUAL PULL STATION HANDLE SHALL BE BETWEEN 42" & 48" AFF CABINET RECEPT. TELE/DATA OUTLET TV OUTLET ELECTRICAL EQUIP. CLEARANCE ELECTRICALEQUIPMENT NO T E # 1 N O T E #4 NOTE#3 NOTE#2 NOTES: 1. THE MINIMUM HEADROOM OF WORKING SPACE SHALL BE 6 1/2FT. 2. THE WIDTH OF THE WORKING SPACE SHALL BE THE WIDTH OF THE EQUIPMENT OR 30", WHICHEVER IS GREATER. THE PANEL DOOR SHALL OPEN AT LEAST 90 DEGREES. 3. ALL CIRCUIT BREAKERS, WHEN IN THIER HIGHEST POSITION, SHALL NOT BE MORE THAN 6FT 7 IN. ABOVE THE FINISHED FLOOR. 4. 3FT CLEARANCE IF 0-150V TO GROUND, 3.5FT CLEARANCE IF 151-600V TO GROUND. 4FT IF EXPOSED LIVE PARTS ON BOTH SIDES OF THE WORKING SPACE. GENERAL NOTES: A. ALL WORKING SPACE CLEARANCES ARE FROM THE FACE OF THE EQUIPMENT. 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:31 AM E0.0 EL E C T R I C A L S Y M B O L S & D E T A I L S 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L SCALE: 1/16" = 1'-0"1 PARTIAL OVERALL PLAN KEY NOTES:# 1 EXISTING 12" BASKET CABLE TRAY TO REMAIN AND BE RE-USED AS MUCH AS POSSIBLE; EXTEND EXISTING TRAY AS INDICATED ON NEW DRAWINGS. FIELD VERIFY EXACT ROUTING AND MODIFY AS NEEDED TO ACCOMIDATE REMODEL. 2 EXTEND EXISTING CABLE TRAY SYSTEM AS INDICATED; FIELD VERIFY CABLE TRAY ROUTING PRIOR TO WORK. 3 E.C. SHALL PROVIDE AND INSTALL NEW 150A FEEDER FOR RELOCATION OF PANEL 'EH5'. PROVIDE AND INSTALL 2"C.,4#1/0+1#6G. ROUTE CONDUIT ABOVE NEW & EXISTING CEILINGS TO EXISTING SWITCHBOARD 'EM3'. RECONNECT NEW FEEDER TO EXISTING CIRCUIT BREAKER THAT ORIGINALLY FED PANEL. FIELD VERIFY ROUTING OF CONDUIT AND PROVIDE PULL-BOXES AS NEEDED. SECURITY & ACCESS CONTROL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION CARD READER; E.C. SHALL PROVIDE ROUGH-IN AND 1/2" C. TO ABOVE ACCESSIBLE CEILING.CR CONNECTION TO DOOR FRAME FOR ACCESS CONTROL. PROVIDE AND INSTALL A 3/4" CONDUIT WITH PULL CORD FROM WIRING CHASE IN DOOR FRAME TO ABOVE NEAREST ACCESSIBLE CEILING. E.C. SHALL ARRANGE A PRE-INSTALLATION MEETING WITH G.C. AND DOOR HARDWARE SUPPLIER TO COORDINATE EXACT PLACEMENT PRIOR TO ROUGH-IN. GENERAL SECURITY & ACCESS CONTROL NOTES: NORTH 32'16'0" DN P P SDSD SD P P F P P SD SD SD SD P P SD SD SD SD P F SD F F F F F F F F F F F P-TUBE SYSTEM P-TUBE SYSTEM 1 'EH5' 'E9' 'A1' 'EH4' 'A''E4' 'PA/NURSE CALL' 2 3 3 4 5 6 3 7 MAU-3(E) 8 8 8 88 8 8 8 8 8 8 910 9 10 910 910 910 9 10 9 10 9 10 9 10 9 10 10 10 9 10 11 12 11 A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH-IN, ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND COVERS. B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES. C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED. D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SHALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC. E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER. F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC. G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK. H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEND AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE- INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING. J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANICAL EQUIPMENT TO BE REMOVED OR RELOCATED. K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS. L. CONTRACTOR TO PROVIDE MINIMUM WORKING CLEARANCES AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS. M. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITION AND COMPLIES WITH SPECIFICATIONS. N. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS. O. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS. GENERAL NOTES: KEY NOTES:# 1 ALL EXISTING LIGHTING, SWITCHES, RECEPTACLES, FIRE ALARM, DATA, NURSE CALL DEVICES AND ETC. WITHIN THIS AREA IS TO BE DISCONNECTED AND REMOVED TO ACCOMMODATE REMODEL (UNLESS SPECIFICALLY INDICATED OTHERWISE). REMOVE ALL ASSOCIATED CONDUIT AND CONDUCTORS BACK TO SOURCE, MAINTAIN/RE-ESTABLISH CONTINUITY TO ANY AND ALL DOWNSTREAM EQUIPMENT/DEVICES THAT ARE TO REMAIN. 2 EXISTING PA AND NURSE CALL SYSTEM EQUIPMENT TO BE REMOVED AND RELOCATED BY OWNER; FIELD COORDINATE PRIOR TO DEMOLITION. 3 EXISTING PANEL TO REMAIN ACTIVE; FIELD LOCATE AND PROTECT DURING CONSTRUCTION; UTILIZE EXISTING PANEL FOR NEW CIRCUITING INDICATED. 4 EXISTING PANEL TO BE DISCONNECTED AND REMOVED. REMOVE ALL ASSOCIATED CONDUITS AND CONDUCTORS BACK TO SOURCE. E.C. SHALL FIELD VERIFY ANY EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN AND EXTEND THEM TO EXISTING PANEL 'A' AS REQUIRED. E.C. SHALL TURN OVER ALL EXISTING BRANCH BREAKER IN PANEL TO OWNER FOR THEIR USE. 5 EXISTING PANEL TO BE DISCONNECTED, REMOVED AND RELOCATED. REMOVE ASSOCIATED FEEDER CONDUIT AND CONDUCTORS BACK TO SOURCE. EXISTING BRANCH CIRCUITS THAT REMAIN SHALL BE PULLED BACK TO ABOVE ACCESSIBLE CEILING SPACE AND EXTENDED TO NEW PANEL LOCATION. PANEL SHALL BE REFED OVERHEAD AS INDICATED ON DRAWINGS. 6 EXISTING PANEL(S) TO BE DISCONNECTED AND REMOVED. REMOVE ALL ASSOCIATED CONDUITS AND CONDUCTORS BACK TO SOURCE. E.C. SHALL FIELD VERIFY ANY EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN AND EXTEND THEM TO EXISTING PANEL 'E4' AS REQUIRED. E.C. SHALL TURN OVER ALL EXISTING BRANCH BREAKER IN PANEL TO OWNER FOR THEIR USE. 7 EXISTING PNEUMATIC TUBE SYSTEM TO REMAIN ACTIVE; LOCATE AND PROTECT DURING CONSTRUCTION. 8 EXISTING FIRE/SMOKE DAMPER TO REMAIN FUNCTIONAL, UNLESS DUCTWORK IS BEING REMOVED. LOCATE AND PROTECT DURING CONSTRUCTION, COORDINATE WITH M.C. 9 EXISTING BOOSTER FAN TO BE REMOVED BY M.C. E.C. SHALL ELECTRICALLY DISCONNECT AND REMOVE ALL ASSOCIATED CONDUCTORS BACK TO SOURCE. 10 EXISTING HEAT PUMP TO BE REMOVED BY M.C. E.C. SHALL ELECTRICALLY DISCONNECT AND REMOVE ALL ASSOCIATED CONDUCTORS BACK TO SOURCE. 11 EXISTING IN-LINE FAN TO REMAIN; E.C. SHALL PROVIDE NEW CIRCUITING AS INDICATED. 12 EXISTING MECHANICAL UNIT TO REMAIN ACTIVE; RE-ESTABLISH CIRCUITING TO UNIT AS REQUIRED. 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:32 AM E0.1 EX I S T I N G E L E C T R I C A L P L A N 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L SCALE: 3/16" = 1'-0"1 EXISTING ELECTRICAL PLAN NORTH 8'4'0" LOCKERS TABLETABLE TABLETABLE LOCKERS C DCD D VIT A L S FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL TWIN IC E MA C H I N E FU L L SE R V I N G WIN D O W CO M P U T E R CO M P U T E R LOCKING STORAGE CABINET LOCKING STORAGE CABINET DN WDD WDD WD D S CD2 S CD2 WDD D1 D1 S CD1 S CD1 D1 WD D S CD1 S CD1 WP1 WP1 D2 D2 S CD1 SCD1 S CD 1 D1 WDD WDD WDD D1 D1 D1 Override D1 S CD2 D1 D1D1 D1 D1 D1 D1 D1 D1 D1D1 D1D1 D1 D1 D1 D1OverrideOv e r r i d e Ov e r r i d e Ov e r r i d e Override Override S CD1 S CD1 SCD1 SCD1 S CD1 S CD1 S CD1 S CD1 D1 SCD1 EXISTING CORRIDOR 200 REC'P 201 SECURITY VESTIBULE 202 VISITING 203 SHAREDDOCTOR'S OFFICE 204 MMH STAFF PATIO 205 T.R. 206 SECLUSION 207 OBSERVATION/SECURITY VEST. 208 CORRIDOR 209 DAY ROOM 210 GROUP THERAPY / DINING 211 CORRIDOR 212 THERAPY 213 DIRECTOR'S OFFICE 214 EXAM 215 CORRIDOR 216 DUAL OCCUPANTPATIENT ROOM 217 T.R. 218 T.R. 219 DUAL OCCUPANTPATIENT ROOM 220 EXISTING STAIR 221 SECURITY VESTIBULE 222 DUAL OCCUPANT PATIENT ROOM 223 T.R.224 T.R. 225 SINGLEOCCUPANT PATIENT ROOM 226 CORRIDOR 227 T.R. 228 SINGLEOCCUPANT PATIENT ROOM 229 DUAL OCCUPANTPATIENT ROOM 230 T.R. 231 T.R. 232 DUAL OCCUPANT PATIENT ROOM 233 STORAGE 234 MEDIA CENTER 235 CORRIDOR 236 NURSES WORKROOM 237 MED. STORAGE/DISPENSARY 238 NURSES STATION 239 NURSES STATION 240 STAFFF T.R. 241 TEAM ROOM 242 EVS 243 F4 F4 F4 F4 F3 F3A F5 F5 F6 F7 F4F4 F3 F6 F3 F8 FE1 12' -0" CONNECT TO NEAREST120V UNSWITCH CIRCUIT F7 F3A F3 F6 F5F5 F4F4 F4F4 F3A F3 F6 F7 F5 F4 F4 F4 F5 F4 F4 F4 F7F3AF3 F6 F7 F3A F3 F6 F4 F5F5 F4 F4F4 F7F7 F3A F3 F6 F3A F3 F6 F5 F5 F5 F5 F4 F4 F4 F4 F4 F4 FX1FX1 FX1 FX1 FX1 NLF2 F2 (TYP)F1 NLF1 (TYP)F1 (TYP)F1 (TYP)F1 NLF1 NLF1 (TYP)F1 (TYP)F1 NLF1 (TYP)F1 FX1 (TYP)F1 NLF1 NLF1 'A' 'E4' NLF1 (TYP)F1 (TYP)F1 F1 F9 E4-26 1 1 1 2 2 2 3 3 1 1 1 1 1 1 FX1 NLF1 NLF1 NLF1 NLF1 1 1 1 E4-28 3 3 E4-30 (TYP)F1 E4-32 A-28 4 4 4 4 4 4 4 4 A-30 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 (TYP)F1 5 5 5 5 5 5 5 5 5 5 5 5 5 5 A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES: KEY NOTES:# 1 CONNECT LIGHT FIXTURE TO EXISTING "LIFE SAFETY" LIGHTING CIRCUIT IN AREA; FIELD VERIFY CIRCUIT LOCATION. FIXTURE SHALL OPERATE AS A NIGHT-LIGHT. 2 EXISTING LIGHTING IN THIS AREA TO REMAIN ACTIVE; FIELD LOCATION AND PROTECT DURING CONSTRUCTION. MAINTAIN/RE-ESTABLISH CONTINUITY AND CONTROLS TO EXISTING LIGHTING AS REQUIRED TO MAINTAIN ORIGINAL FUNCTIONALITY. 3 OVERRIDE SWITCH FOR PATIENT ROOM LIGHTING; SWITCH SHALL OVERRIDE ALL LIGHTING IN THE PATIENT ROOM EXCEPT FOR NIGHT-LIGHT AND BATHROOM LIGHTING. 4 CONNECT ALL OCCUPANCY SENSORS IN ROOM/CORRIDOR IN PARALLEL SO THAT ANY OCC. SENSOR WILL TURN ON ALL LIGHTING IN ROOM/CORRIDOR. 5 ALL WALL SWITCH DEVICE COVER PLATES IN THIS ROOM SHALL BE SUICIDE/TAMPER RESISTANT. SECURINGHOSPITALS.COM P/N: 812-S73-PCW-**-**, PROVIDE TYPE BASED ON DEVICE. 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:34 AM E1.0 LI G H T I N G P L A N 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L SCALE: 3/16" = 1'-0"1 LIGHTING PLAN NORTH 8'4'0" Exit lighting and Exit signs to be in compliance with IBC Section 1008 and 1013 LOCKERS TABLETABLE TABLETABLE LOCKERS C DCD D VIT A L S FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL TWIN IC E MA C H I N E FU L L SE R V I N G WIN D O W CO M P U T E R CO M P U T E R LOCKING STORAGE CABINET LOCKING STORAGE CABINET DN CR CRCRCRCRCR C R C R TV2 J J LC WAC LC WSP LC WSP LC WSP LC WSP LC WSP LC WSP LC WSP W4 W4 F F F F F F F F F F F F F S HP-7S HP-8 SHP - 9 SHP - 1 0 SHP - 1 1 S HP - 1 SHP - 2 S HP -3 S HP - 1 4 S HP-4 SHP-5SHP-6 EXISTING CORRIDOR 200 REC'P 201 SECURITY VESTIBULE 202 VISITING 203 SHARED DOCTOR'SOFFICE 204 MMH STAFFPATIO205 T.R. 206 SECLUSION 207 OBSERVATION/SECURITY VEST. 208 CORRIDOR 209 DAY ROOM210 GROUP THERAPY / DINING 211 CORRIDOR212 THERAPY 213 DIRECTOR'S OFFICE 214 EXAM 215 CORRIDOR 216 DUAL OCCUPANT PATIENT ROOM 217 T.R.218T.R.219 DUAL OCCUPANT PATIENT ROOM 220 EXISTING STAIR 221 SECURITY VESTIBULE 222 DUAL OCCUPANT PATIENT ROOM 223 T.R. 224 T.R.225 SINGLE OCCUPANTPATIENT ROOM 226 CORRIDOR 227 T.R. 228 SINGLEOCCUPANT PATIENT ROOM 229 DUAL OCCUPANTPATIENT ROOM 230 T.R. 231 T.R. 232 DUAL OCCUPANT PATIENT ROOM 233 STORAGE 234 MEDIA CENTER 235 CORRIDOR 236 NURSESWORKROOM 237 MED. STORAGE/DISPENSARY 238 NURSES STATION 239 NURSESSTATION 240 STAFFF T.R. 241 TEAM ROOM 242 EVS 243 1 42" 42" 42" 42" 42" 42" 42" 'A''E4' 42" AC AC AC AC AC AC REF AC 42" ACAC AC AC AC AC AC AC 'EH4' E E E E E E E AC 'EH5' MAU-3(E) 22 3 4 4 A-10,12 A-2,4,6 A-13,15,17 E4-8 A-21,23 E4-1 A-8 A-5 E A-19 A-14,16,18 2 2 A-25,27,29 2 2 2 2 A-7,92 2 2 2 2 2 A-1,3E4-3 E4-3 5 6 EH5-18,20,22 EH5-26,28,30 6 BF-1 HP-1 BF-2HP-2 BF-3 HP-3 BF-4HP-4 BF-5 HP-5 BF-13 HP-13 HP-6BF-7 HP-7 BF-8 HP-8 BF-9 HP-9 BF-10 HP-10 BF-11 HP-11 BF-12 HP-12 BF-14HP-14 3D-4 2D-3 3D-4 3D-4 2D-3 3D-4 3D-4 3D-4 3D-4 3D-4 2D-3 1D-5 2D-3 3D-4 3D-4 3D-4 3D-4 3D-4 3D-4 2D-3 3D-4 3D-4 3D-4 2D-3 2D-3 7 S A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES: KEY NOTES:# 1 EXISTING PNEUMATIC TUBE SYSTEM TO REMAIN ACTIVE; LOCATE AND PROTECT DURING CONSTRUCTION. 2 ALL RECEPTACLES IN THE PATIENT ROOM SHALL BE CONTROLLED VIA WIRELESS RELAY SO THAT RECEPTACLES CAN BE DE-ENERGIZED BY PERSONNEL AT THE NURSES STATION. RECEPTACLES SHALL ALSO BE UL TAMPER-RESISTANT AND COVER PLATES SHALL BE SUICIDE/TAMPER RESISTANT. SECURINGHOSPITALS.COM P/N: 812-S73-PCW-**-**, PROVIDE TYPE BASED ON DEVICE. 3 PROVIDE ROUGH-IN FOR SECURITY DOOR RELEASE BUTTON WITH 1/2" C TO ABOVE ACCESSIBLE CEILING LOCATION. COORDINATE WITH SECURITY CONTRACTOR. 4 PROVIDE AND INSTALL A 120V CIRCUIT IN J-BOX ABOVE CEILING FOR ACCESS CONTROL POWER SUPPLY; COORDINATE WITH OWNER SECURITY CONTRACTOR. 5 EXISTING MECHANICAL UNIT TO REMAIN ACTIVE; RE-ESTABLISH CIRCUITING TO UNIT AS REQUIRED. 6 EXISTING IN-LINE FAN TO REMAIN; E.C. SHALL PROVIDE NEW CIRCUITING AS INDICATED. 7 ALL 120V RECEPTACLE CIRCUITS IN THIS ROOM SHALL BE PROVIDED WITH A REDUNDANT GROUND AS REQUIRED BY ARTICLE 517 OF THE NEC. 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:34 AM E2.0 PO W E R / D A T A P L A N 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L SCALE: 3/16" = 1'-0"1 POWER/DATA PLAN 8'4'0" NORTH WIRELESS RECEPTACLE CONTROL SCHEDULE TYPE DESCRIPTION MFGR. CATALOG # NOTES APPROVED EQUALS WIRELESS CONTROLS W4 WAVELINX 4-BUTTON WALL STATION, FIELD PROGRAMMABLE, CUSTOM ENGRAVED BUTTONS COOPER W4S-S3-** 1 ACUITY BRANDS WAC WAVELINX WIRELESS AREA CONTROLLER, PROVIDE 120V PoE INJECTOR COOPER WAC- POE & WPOE-120 2 ACUITY BRANDS WSP WAVELINX WIRELESS RELAY SWITCHPACK WITH 0-10V DIMMING, 20A RELAY COOPER WSP-MV-010 2 ACUITY BRANDS NOTES: 1. E.C. SHALL PROVIDE CUSTOM ENGRAVING OF SWITCH BUTTONS INDICATING ROOM THAT IS BEING CONTROLLED; FIELD VERIFY ENGRAVING WITH OWNER PRIOR TO ORDERING. 2. MOUNT DEVICE ABOVE ACCESSIBLE CEILING; FIELD LOCATE. GENERAL NOTES: A. E.C. SHALL BE RESPONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE WIRELESS CONTROL SYSTEM TO FUNCTION AS INDICATED ON THE DRAWINGS AND SHALL INCLUDE ALL REQUIRED COST IN THE BASE BID. ALL PROGRAMMING/COMMISSIONING SHALL BE DONE BY A FACTORY CERTIFIED OR TRAINED PERSON. LOCKERS TABLETABLE TABLETABLE LOCKERS C DCD D VIT A L S FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL TWIN IC E MA C H I N E FU L L SE R V I N G WIN D O W CO M P U T E R CO M P U T E R LOCKING STORAGE CABINET LOCKING STORAGE CABINET DN SDSD SD SD SD SD SD SD SD SD SD F P PP P P P P P P P SD 1 1 1 1 1 1 1 1 1 1 1 1 A. PROVIDE ALL EQUIPMENT, MATERIALS AND LABOR NECESSARY TO EXPAND THE EXISTING SIMPLEX GRINNELL FIRE ALARM SYSTEM. THE SYSTEM ADDITION SHALL BE CONNECTED DIRECTLY TO THE EXISTING MAIN FIRE ALARM PANEL. THE INSTALLATION SHALL BE AS RECOMMENDED BY THE MANUFACTURER AND ACCEPTED BY THE LOCAL AHJ. WHEN THE SYSTEM IS COMPLETE, A FACTORY REPRESENTATIVE SHALL TEST THE SYSTEM, MAKE ADJUSTMENTS AND PLACE THE SYSTEM IN OPERATING ORDER. B. WITHIN 30 DAYS AFTER THE CONTRACT AWARD AND PRIOR TO THE PURCHASE OF ANY EQUIPMENT, THE FIRE ALARM SYSTEM CONTRACTOR SHALL SUBMIT FOR APPROVAL SIX (6) COPIES OF THE FOLLOWING: · A LIST OF MATERIALS THAT ARE TO BE USED ON THE PROJECT, INCLUDING MANUFACTURER, MODEL NUMBER AND TECHNICAL INFORMATION. · PRELIMINARY CIRCUIT DIAGRAMS SHOWING INTERCONNECTION OF ALL MONITORING, NOTIFICATION AND ANNUNCIATION DEVICES, PANELS AND WIRING COUNTS. DIAGRAMS ARE TO BE 11"X17", DONE IN A GOOD WORKMANLIKE MANNER. · TECHNICAL MANUALS FOR ALL OF THE EQUIPMENT THAT IS TO BE USED ON THE PROJECT. · SUBMIT SHOP DRAWINGS AND REQUIRED CALCULATIONS TO THE LOCAL AHJ. OBTAIN A WRITTEN LETTER OF ACCEPTANCE OF THE PROPOSED SYSTEM AND INCLUDE WITH THE SHOP DRAWING SUBMITTAL TO THE ENGINEER. C. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED POWER SUPPLIES, ELECTRONICS AND CONNECTIONS TO MODIFY EXISTING SYSTEM TO ACCEPT NEW ADDITION. THE COMPLETE SYSTEM SHALL MAINTAIN A UL LISTING. D. ELECTRICAL CONTRACTOR SHALL INCLUDE A $2,000.00 CASH ALLOWANCE IN THE BID FOR MISCELLANEOUS ADDITIONS AND/OR REQUIREMENTS IMPOSED BY THE LOCAL AHJ. FIRE ALARM EXPANSION NOTES: KEY NOTES:# 1 EXISTING FIRE/SMOKE DAMPER TO REMAIN FUNCTIONAL, UNLESS DUCTWORK IS BEING REMOVED. LOCATE AND PROTECT DURING CONSTRUCTION, COORDINATE WITH M.C. 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:35 AM E3.0 FI R E A L A R M P L A N 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L SCALE: 3/16" = 1'-0"1 FIRE ALARM PLAN 8'4'0" NORTH FIRE ALARM SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION DETECTOR SUBSCRIPTS P PHOTOELECTRIC SMOKE DETECTOR D DUCT SMOKE DETECTOR ID IN-DUCT SMOKE DETECTOR H HEAT DETECTOR M MULTI-STATION SMOKE DETECTOR (120V W/BATTERY BACKUP) FIRE ALARM CONTROL PANEL (WALL MOUNTED, TOP AT 6'-0' AFF) F FACP NOTIFICATION DEVICE EXTENDER PANEL. PROVIDE QTY AS REQUIRED BASED ON DEVICE VOLTAGE DROP CALC'S PER NFPA 72 REQUIREMENTS. (WALL MOUNTED, TOP AT 5'-0' AFF) REMOTE ANNUCIATOR PANEL (FLUSH MOUNTED IN WALL AT 5'-0' AFF) NAC RA MANUAL PULL STATION (MOUNTING HEIGHT PER ADA & NFPA 72) MAGNETIC DOOR HOLD OPEN ADDRESSABLE CONTROL/RELAY MODULE MM CM ADDRESSABLE MONITORING MODULE FIRE ALARM FLOW SWITCH FIRE ALARM TAMPER SWITCH FS TS WALL MOUNTED FIRE ALARM HORN ONLY WALL MOUNTED FIRE ALARM STROBE ONLY (CANDELA RATING AS INDICATED) #ADDRESSABLE DETECTOR WITH BASE ## ##CEILING MOUNTED FIRE ALARM STROBE ONLY (CANDELA RATING AS INDICATED) ## ## WALL MOUNTED FIRE ALARM HORN STROBE (CANDELA RATING AS INDICATED) CEILING MOUNTED FIRE ALARM HORN STROBE (CANDELA RATING AS INDICATED) EXTERIOR 120V FIRE BELL, INSTALL NEXT TO FDC. FIRE/SMOKE DAMPER; COORDINATE LOCATIONS WITH MECH. DRAWINGSSD A. DO NOT INSTALL MORE THAN (10) NOTIFICATION APPLIANCES ON ANY SINGLE CLASS "A" SIGNAL CIRCUIT. DO NOT EXCEED 400 FT. OF NO. 14 WIRE IN THE TOTAL LOOP. B. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT RANGE BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS, LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL NOTIFICATION APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE LOCATED AT A COMMON HEIGHT. C. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET ADA REQUIREMENTS. D. DO NOT CONNECT THE FIRE ALARM SYSTEM TO ANY DEVICE WHICH HAS A POWER HELD CONTACTS.(FLOW, TAMPER, HOOD SYSTEM, DUCT DETECTOR, ETC..FALSE ALARM WILL OCCUR. E. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL CONDUCTOR QUANTITIES PER FIRE ALARM SYSTEM SUPPLIER, AND AS PER NFPA AND NEC REQUIREMENTS. F. DO NOT INSTALL ANY SMOKE OR HEAT DETECTORS WITHIN 3 FEET OF ANY AIR DIFFUSER. G. DO NOT EXCEED 2500 FEET ON ANY ADDRESSABLE DEVICE RUN. DO NOT EXCEED 120 DEVICES ON ANY ONE ADDRESSABLE DEVICE RUN. H. ALL AIR HANDLING EQUIPMENT 2000 CFM OR MORE MUST BE SHUT DOWN UPON FIRE ALARM AS PER LIFE SAFETY CODES. I. ALL CLASS "B" INITIATING CIRCUITS WITH ADDRESSABLE DEVICES NEED EOLR. (END OF LINE RESISTORS). J. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15' FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING. K. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3 TEMPORAL PATTERN. L. ALL WIRING AND CONDUIT ROUTING TO BE AS DESCRIBED ON SUPPLIED SHOP DRAWINGS. FIRE ALARM PLAN IS SHOWN FOR GENERAL LOCATION AND LAYOUT ONLY. M. THE FIRE ALARM SYSTEM TO BE IN COMPLIANCE WITH ALL APPLICABLE LOCAL, STATE AND ADA REQUIREMENTS. N. ELECT. CONTR. TO CONNECT SPRINKLER SYSTEM TAMPER SWITCHES AND FLOW VALVES TO FIRE ALARM SYSTEM AS REQUIRED. SEE FIRE SPRINKLER SYSTEM DRAWINGS FOR EXACT LOCATIONS AND QUANTITIES. GENERAL FIRE ALARM SYSTEM NOTES 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:36 AM E5.0 EL E C T R I C A L S C H E D U L E S 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:47 A TOTAL AMPS:59 A 65 A 51 A TOTAL LOAD:7.0 kVA 7.6 kVA 6.1 kVA 83 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 84 81 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 82 79 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 80 77 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 78 75 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 76 73 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 74 71 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 72 69 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 70 67 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 68 65 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 66 63 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 64 61 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 62 59 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 60 57 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 58 55 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 56 53 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 54 51 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 52 49 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 50 47 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 48 45 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 46 43 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 44 41 42 39 40 37 38 35 36 33 34 31 32 29 Receptacle 20 A 1 770 1160 1 20 A Lighting 30 27 Receptacle 20 A 1 950 1375 1 20 A Lighting 28 25 Receptacle 20 A 1 950 26 23 Receptacle 20 A 1 720 24 21 Receptacle 20 A 1 720 22 19 Receptacle 20 A 1 900 20 17 Ice Maker 20 A 1 180 720 1 20 A Receptacle 18 15 Receptacle 20 A 1 540 720 1 20 A Receptacle 16 13 Receptacle 20 A 1 720 900 1 20 A Receptacle 14 11 900 1 20 A Receptacle 12 9 Receptacle 20 A 1 770 900 1 20 A Receptacle 10 7 Receptacle 20 A 1 950 900 1 20 A Receptacle 8 5 Receptacle 20 A 1 720 900 1 20 A Receptacle 6 3 Receptacle 20 A 1 770 900 1 20 A Receptacle 4 1 Receptacle 20 A 1 770 900 1 20 A Receptacle 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT EXISTING PANEL NOTES: MFG & MODEL:GE/A SERIES II DIMENSIONS:20"W x 5.8"D x *"H FEED: ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:FLUSH WIRES:4 PANEL AMPS:225 A FED FROM:M PHASES:3 PANEL TYPE:MLO BEHAVIOR HEALTH LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:N/A PROJECT: PANEL: A PAYNE ENGINEERING S = SHUNT-TRIP BREAKER G = GFCI BREAKER E = EXISTING CIRCUIT A = ARC-FAULT BREAKER GP = GFEPD BREAKER N = PROVIDE AND INSTALL NEW CIRCUIT BREAKER (SIZE AS INDICATED) BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:12 A TOTAL AMPS:23 A 12 A 4 A TOTAL LOAD:2.6 kVA 1.3 kVA 0.5 kVA 83 ---- -- -- 0 0 1 20 A -- SPARE 84 81 STORAGE HEATER (E) -- 20 A 2 0 0 1 20 A -- SPARE 82 79 ---- -- -- 0 0 1 20 A -- SPARE 80 77 STORAGE HEATER (E) -- 20 A 2 0 0 1 20 A -- SPARE 78 75 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 76 73 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 74 71 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 72 69 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 70 67 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 68 65 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 66 63 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 64 61 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 62 59 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 60 57 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 58 55 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 56 53 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 54 51 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 52 49 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 50 47 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 48 45 SPARE -- 20 A 1 0 0 -- -- -- --46 43 SPARE -- 20 A 1 0 0 2 20 A -- LTG - OUTSIDE (RELOCATED... 44 41 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 42 39 SPARE -- 20 A 1 0 40 37 SPARE -- 20 A 1 0 38 35 SPARE -- 20 A 1 0 36 33 SPARE -- 20 A 1 0 34 31 SPARE -- 20 A 1 0 803 1 20 A Lighting 32 29 SPARE -- 20 A 1 0 468 1 20 A Lighting 30 27 SPARE -- 20 A 1 0 534 1 20 A Lighting 28 25 SPARE -- 20 A 1 0 667 1 20 A Lighting 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 900 1 20 A Receptacle 8 5 6 3 Access Control 20 A 1 1000 4 1 Receptacle 20 A 1 540 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT EXISTING PANEL NOTES: MFG & MODEL:GE/A SERIES II DIMENSIONS:20"W x 5.8"D x *"H FEED: ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:FLUSH WIRES:4 PANEL AMPS:225 A FED FROM:EM2 PHASES:3 PANEL TYPE:MLO BEHAVIOR HEALTH LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:N/A PROJECT: PANEL: E4 PAYNE ENGINEERING S = SHUNT-TRIP BREAKER G = GFCI BREAKER E = EXISTING CIRCUIT A = ARC-FAULT BREAKER GP = GFEPD BREAKER N = PROVIDE AND INSTALL NEW CIRCUIT BREAKER (SIZE AS INDICATED) BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:35 A TOTAL AMPS:38 A 33 A 33 A TOTAL LOAD:4.6 kVA 4.0 kVA 4.0 kVA 41 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 42 39 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 40 37 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 38 35 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 36 33 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 34 31 SPARE -- 20 A 1 0 0 1 20 A -- RECPT. MAU-3 (E) 32 29 SPARE -- 20 A 1 0 961 -- -- -- --30 27 SPARE -- 20 A 1 0 961 -- -- -- --28 25 HVAC BF-3 20 A 1 600 961 3 20 A MF-1 26 23 HVAC BF-13 20 A 1 600 0 1 20 A -- SPARE 24 21 HVAC BF-12 20 A 1 600 721 -- -- -- --22 19 HVAC BF-2 20 A 1 600 721 -- -- -- --20 17 HVAC BF-14 20 A 1 600 721 3 20 A E MAU-3 18 15 HVAC BF-4 20 A 1 600 0 1 20 A -- SPARE 16 13 HVAC BF-5 20 A 1 600 0 1 20 A -- SPARE 14 11 HVAC BF-8 20 A 1 600 0 1 20 A -- SPARE 12 9 HVAC BF-7 20 A 1 600 0 1 20 A -- SPARE 10 7 HVAC BF-9 20 A 1 600 0 1 20 A -- SPARE 8 5 HVAC BF-10 20 A 1 600 0 1 20 A -- SPARE 6 3 HVAC BF-11 20 A 1 600 0 1 20 A -- SPARE 4 1 HVAC BF-1 20 A 1 600 0 1 20 A -- SPARE 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT EXISTING PANEL TO BE RELOCATED NOTES: MFG & MODEL:GE/A SERIES II DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:FLUSH WIRES:4 PANEL AMPS:225 A FED FROM:EM3 PHASES:3 PANEL TYPE:MLO BEHAVIOR HEALTH LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:N/A PROJECT: PANEL: EH5 PAYNE ENGINEERING S = SHUNT-TRIP BREAKER G = GFCI BREAKER E = EXISTING CIRCUIT A = ARC-FAULT BREAKER GP = GFEPD BREAKER N = PROVIDE AND INSTALL NEW CIRCUIT BREAKER (SIZE AS INDICATED) BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:73 A TOTAL AMPS:74 A 76 A 69 A TOTAL LOAD:8.8 kVA 9.1 kVA 8.3 kVA 41 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 42 39 ---- -- -- 607 0 1 20 A -- SPARE 40 37 HVAC HP-10 N 15 A 2 607 0 1 20 A -- SPARE 38 35 ---- -- -- 607 0 1 20 A -- SPARE 36 33 HVAC HP-9 N 15 A 2 607 0 1 20 A -- SPARE 34 31 ---- -- -- 607 0 1 20 A -- SPARE 32 29 HVAC HP-8 N 15 A 2 607 0 1 20 A -- SPARE 30 27 ---- -- -- 874 961 -- -- -- --28 25 HVAC HP-7 N 15 A 2 874 961 -- -- -- --26 23 ---- -- -- 874 961 3 20 A E MF-1 24 21 HVAC HP-6 N 15 A 2 874 0 1 20 A -- SPARE 22 19 ---- -- -- 607 0 1 20 A -- SPARE 20 17 HVAC HP-5 N 15 A 2 607 0 1 20 A -- (E) F/A Smoke Dampers 18 15 ---- -- -- 874 607 -- -- -- --16 13 HVAC HP-4 N 15 A 2 874 607 2 15 A N HVAC HP-14 14 11 ---- -- -- 607 1714 -- -- -- --12 9 HVAC HP-3 N 15 A 2 607 1714 2 30 A N HVAC HP-13 10 7 ---- -- -- 607 1714 -- -- -- --8 5 HVAC HP-2 N 15 A 2 607 1714 2 30 A N HVAC HP-12 6 3 ---- -- -- 607 724 -- -- -- --4 1 HVAC HP-1 N 15 A 2 607 724 2 15 A N HVAC HP-11 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT EXISTING PANEL NOTES: MFG & MODEL:GE/A SERIES II DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:FLUSH WIRES:4 PANEL AMPS:225 A FED FROM:EM3 PHASES:3 PANEL TYPE:MLO BEHAVIOR HEALTH LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:N/A PROJECT: PANEL: EH4 PAYNE ENGINEERING MECHANICAL - WATER SOURCE HEAT PUMP SCHEDULE ID # VOLTS PH. MCA MOCP PANEL CIRCUIT FEEDER NOTES HP 1 208 V 1 7.3 A 15 A EH4 1,3 3/4"C.,2#12+1#12G 2 HP 2 208 V 1 7.3 A 15 A EH4 5,7 3/4"C.,2#12+1#12G 2 HP 3 208 V 1 7.3 A 15 A EH4 9,11 3/4"C.,2#12+1#12G 2 HP 4 208 V 1 10.5 A 15 A EH4 13,15 3/4"C.,2#12+1#12G 2 HP 5 208 V 1 7.3 A 15 A EH4 17,19 3/4"C.,2#12+1#12G 2 HP 6 208 V 1 10.5 A 15 A EH4 21,23 3/4"C.,2#12+1#12G 2 HP 7 208 V 1 10.5 A 15 A EH4 25,27 3/4"C.,2#12+1#12G 2 HP 8 208 V 1 7.3 A 15 A EH4 29,31 3/4"C.,2#12+1#12G 2 HP 9 208 V 1 7.3 A 15 A EH4 33,35 3/4"C.,2#12+1#12G 2 HP 10 208 V 1 7.3 A 15 A EH4 37,39 3/4"C.,2#12+1#12G 2 HP 11 208 V 1 8.7 A 15 A EH4 2,4 3/4"C.,2#12+1#12G 2 HP 12 208 V 1 20.6 A 30 A EH4 6,8 3/4"C.,2#10+1#12G 2 HP 13 208 V 1 20.6 A 30 A EH4 10,12 3/4"C.,2#10+1#12G 2 HP 14 208 V 1 7.3 A 15 A EH4 14,16 3/4"C.,2#12+1#12G 2 MECHANICAL - BOOSTER FAN SCHEDULE ID # VOLTS PH. WATTS PANEL CIRCUIT FEEDER NOTES BF 1 120 V 1 600 W EH5 1 3/4"C.,2#12+1#12G 2 BF 2 120 V 1 600 W EH5 19 3/4"C.,2#12+1#12G 2 BF 3 120 V 1 600 W EH5 25 3/4"C.,2#12+1#12G 2 BF 4 120 V 1 600 W EH5 15 3/4"C.,2#12+1#12G 2 BF 5 120 V 1 600 W EH5 13 3/4"C.,2#12+1#12G 2 BF 7 120 V 1 600 W EH5 9 3/4"C.,2#12+1#12G 2 BF 8 120 V 1 600 W EH5 11 3/4"C.,2#12+1#12G 2 BF 9 120 V 1 600 W EH5 7 3/4"C.,2#12+1#12G 2 BF 10 120 V 1 600 W EH5 5 3/4"C.,2#12+1#12G 2 BF 11 120 V 1 600 W EH5 3 3/4"C.,2#12+1#12G 2 BF 12 120 V 1 600 W EH5 21 3/4"C.,2#12+1#12G 2 BF 13 120 V 1 600 W EH5 23 3/4"C.,2#12+1#12G 2 BF 14 120 V 1 600 W EH5 17 3/4"C.,2#12+1#12G 2 1. E.C. SHALL PROVIDE LOCAL DISCONNECT SWITCH FOR EQUIPMENT; SIZE AND TYPE AS INDICATED IN SCHEDULE. IF FUSED DISCONNECT IS SPECIFIED FOR EQUIPMENT, FUSE PER EQUIPMENT NAMEPLATE RATING. 2. E.C. SHALL PROVIDE LOCAL DISCONNECT RATED, THERMAL-OVERLOAD SWITCH FOR EQUIPMENT; SWITCH RATING SHALL NOT BE LESS THEN CIRCUIT BREAKER SUPPLYING EQUIPMENT. MECHANICAL SCHEDULE NOTES: TEE BAR GRID POWER SUPPLY CONDUIT FOR CEILING OR WALL "J" BOX. SUPPORT WIRE BY ELECTRICAL CONTRACTOR INDEPENDENT OF CEILING SYSTEM. (TYPICAL) ACOUSTIC CEILING TILE SUPPORT CLIPS ALL SIDES ENTRANCE CONDUIT(S) 4" SQUARE BOX RAISED RING TO SUIT WALL RECEPTACLE - 20AMP RATED - SEE SPECIFICATIONS. NORMAL POWER COLOR - (SEE SPEC'S) COVER PLATE - STYLE & COLOR TO BE AS PER SPECIFICATIONS. CIRCUIT NUMBER TO BE WRITTEN ON BACK OF COVER W/FELT-TIP MARKER GREEN INSULATED GROUND CONDUCTOR 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:37 AM E5.1 EL E C . S C H E D U L E S & D E T A I L S 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING VOLTAGE LUMENS COLOR TEMP.(K) MFGR. CATALOG # NOTES EXTERIOR FE1 EXTERIOR LED WALL PACK WALL 12' AFG 120 2000 4000 LUMARK LTG XTOR3B-W-PC1 INTERIOR F1 2X2 ARCHITECTURAL LED TROFFER, 0-10V DIMMING RECESSED 120-277 4000 3500 LITHONIA 2BLT2-40L-ADP-EZ1-LP835 1 F2 6" ROUND RECESSED LED CAN, 0-10V DIMMING RECESSED 120-277 1500 3500 LITHONIA LDN6-35/15-LO6AR-LSS-MVOLT-EZ10 1 F3 6" ROUND RECESSED LED CAN, BEHAVIOR HEALTH RATED RECESSED 120-277 1600 3500 KENALL LTG BHDL6-FF-5BR-22L-35K8-W-CSS-G-RIG6-DV-DIM1 1 F3A 6" ROUND RECESSED LED CAN, BEHAVIOR HEALTH RATED RECESSED 120-277 1000 3500 KENALL LTG BHDL6-FF-5BR-12L-35K8-W-CSS-G-RIG6-DV-DIM1 1 F4 23" DIA. RECESSED GENERAL USE LED, 0-10V DIMMING, BEHAVIORAL HEALTH RATED RECESSED 120-277 4500 3500 VISA LIGHTING CM1988-W-L35K-H-MVOLT-DIM-SCBA 1 F5 3FT LINEAR WALL LED, BEHAVIORAL HEALTH RATED WALL ABOVE BED 120-277 3200 3500 KENALL LTG BHWS-3-0-27L-35K8-DIM1-DV-SYM/G-1 1 F6 VANITY LIGHT, BEHAVIOR HEALTH RATED ABOVE MIRROR 120-277 300 3500 VISA LIGHTING CB1800-L35K-H-MVOLT-WIDE-TOUCHDIM-SCBA-BH1 1 F7 SEMI-RECESS STEPLIGHT, TAMPER-RESISTANT SCREWS, PHOTOCELL CONTROL WALL 14" AFF 120-277 38 3500 KENALL LTG MCSL-HR-SCBA-2L35K-DV-BPC 1 F8 45" DIA. RECESSED TUNABLE LED, BEHAVIORAL HEALTH RATED RECESSED 120V 4800 TUNABLE VISA LIGHTING CM1978-T-TUN2(H)-90CRI-120-SCBA- 1 F9 4FT LED STRIP, 0-10V DIMMING SURFACE/ SUSPENDED 120-277 4000 4000 LITHONIA CLX-L48-4000LM-SEF-RDL-MVOLT-GZ10-40K-80CRI LIFE SAFETY FX1 EDGE LITE EXIT SIGN, GREEN LED, SINGLE FACE/DOUBL FACE WALL OR CEILING 120-277 N/A N/A MULE LTG PVT-U-A-G-S/R-SCBA LIGHTING CONTROL/OCCUPANCY SENSOR SCHEDULE TYPE DESCRIPTION MFGR. CATALOG # NOTES APPROVED EQUALS DIMMER SWITCHES - LINE VOLTAGE D1 LINE VOLTAGE 0-10V DIMMER, ON/OFF/DIMMING PUSH-BUTTONS SENSOR SWITCH sPODMRA-D-** 2,3,4 D2 LINE VOLTAGE 0-10V DIMMER FOR MULTI-WAY OPERATION, ON/OFF/DIMMING PUSH-BUTTONS SENSOR SWITCH sPODMRA MWO-D-** 2,3,4 OCC. SENSORS - CEILING (LINE VOLTAGE) CD2 DUAL-TECHNOLOGY, LINE VOLTAGE, SMALL MOTION 800W MAX LOAD SENSOR SWITCH CMR PDT 9 COOPER, WATTSOPPER, HUBBELL OCC. SENSORS - CEILING (LOW VOLTAGE) CD1 DUAL-TECHNOLOGY, SMALL MOTION 360 DEGREE COVERAGE, LOW VOLTAGE, W/ISOLATED RELAY SENSOR SWITCH CM PDT 9 R 1 COOPER, WATTSTOPPER, HUBBELL OCC. SENSORS - WALL MOUNTED WDD DUAL-TECHNOLOGY, 0-10V DIMMING SENSOR SWITCH WSX-PDT-D 2,5 COOPER, WATTSTOPPER, HUBBELL WP1 PASSIVE-INFRARED, 1-POLE, NEUTRAL REQUIRED SENSOR SWITCH WSX-** 2 COOPER, WATTSTOPPER, HUBBELL 1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO HAVE 0-10V OR STEP-LEVEL DIMMING CONTROL. PROVIDE FIXTURE(S) WITH LED DRIVER(S) AND REQUIRED DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES) AND FIXTURE(S) TO PROVIDE CONTROL AS INDICATED ON DRAWINGS. 2. FIXTURE TO BE CONTINUOUS ROW MOUNTED, LENGTH AS INDICATED ON DRAWINGS. PROVIDE REQUIRED ACCESSORIES/CONNECTORS FOR CONTINUOUS ROW MOUNTING. 3. SCBA - STANDARD COLOR BY ARCHITECT/OWNER (COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.) 4. FIELD ADJUST PENDANT LENGTH AS REQUIRED, VERIFY LENGTH WITH COUNTER AS DIRECTED BY ARCHITECT. 5. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR PLACEMENT AND MOUNTING HEIGHT OF FIXTURES. LIGHT FIXTURE SCHEDULE NOTES: 1. PROVIDE ADDITIONAL POWER PACKS; SENSOR SWITCH PP20 AS NEED FOR QTY OF OCCUPANCY SENSORS/SWITCHES. 2. DEVICE COLOR SHALL MATCH WIRING DEVICES; REFER TO SPECIFICATIONS. 3. REFER TO MANUFACTURER DOCUMENTATION FOR QTY AND SIZE OF CONDUCTORS BETWEEN LOW VOLTAGE SWITCH, SENSOR(S) AND POWER/RELAY PACKS. 4. PROVIDE SECONDARY RELAY PACK; SENSOR SWITCH SP20 AS NEEDED TO PROVIDE DUAL-LEVEL SWITCHING OF FIXTURES. 5. PROVIDE 0-10V DIMMING CONDUCTORS (GRAY & VIOLET) BETWEEN SWITCH AND LIGHT FIXTURES FOR DIMMING CONTROL. 6. PROGRAM ON/OFF TIMES OF RELAY'S AS DIRECTED BY OWNER. PROVIDE COMMISSIONING AS INDICATED IN GENERAL NOTES BELOW. 7. CUSTOM WALL STATION ENGRAVINGS IS REQUIRED FOR WALL STATION(S) AND SHALL BE SPECIFIED/COORDINATED WITH OWNER AFTER PROGRAMING OF SYSTEM. CONTROL & OCCUPANCY SENSOR SCHEDULE NOTES: • E.C. SHALL BE RESPONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE LIGHTING CONTROL SYSTEMS TO FUNCTION AS INDICATED ON THE DRAWINGS AND SHALL INCLUDE ALL REQUIRED COST IN THE BASE BID. FOR AREAS WITH DAYLIGHTING CONTROL, THE DAYLIGHTING SET- POINTS SHALL BE COORDINATED WITH THE OWNER FOR EACH AREA PRIOR TO FINAL PROGRAMMING OF THE DAYLIGHTING SENSOR(S). ALL PROGRAMMING/COMMISSIONING SHALL BE DONE BY A FACTORY CERTIFIED OR TRAINED PERSON. • LIGHTING IS SPACES WITH WIRELESS CONTROLS SHALL BE FIELD TUNED TO FOOTCANDLE LEVELS THAT ARE SATISFACTORY TO THE OWNER DURING PROGRAMMING AND COMMISSIONING OF THE WIRELESS CONTROL SYSTEM. GENERAL LIGHTING CONTROL NOTES: SCALE: NONE1RECESSED LIGHT FIXTURE DETAIL SCALE: NONE2RECEPTACLE MOUNTING DETAIL GENERAL ELECTRICAL REQUIREMENTS 1.1 Submittals: A. As-Built Drawings - 1.Provide as-built drawings per Division 01 requirements. B. Shop Drawings - 1. Prepare submittal for each item of equipment and attach written approval to each indicating that requirements for testing and demonstrating system have been complied with and that shop drawings are correct. 2. Do not purchase equipment before completion of shop drawing review. C. Submit electrical drawings immediately after the award of contract to the local utility companies for their review. All utility charges will be paid by the Owner. Contractor shall coordinate with the utility companies and obtain all required charges and turn over to Owner. 1.2 Requirements of Regulatory Agencies: A. Furnish UL listed equipment where such label is available. Install in conformance with UL standards where applicable. B. Install electrical work in accordance with Drawings and Specifications, edition of NEC in effect at project location,recommendations of NFPA, state and local electrical and building codes, and special codes having jurisdiction over specific portions of work. This includes, but is not limited to the following: 1. National Electrical Code with applicable local amendments 2. Life Safety Code, NFPA 101. 3. International Fire Code 4. International Building Code C. In the event of conflict between Drawings, Specifications and such codes, notify Engineer in writing prior to bid. A ruling will then be made by Engineer in writing. D. Obtain permits and certificates of approval from all authorities having jurisdiction over the installation and pay all fees required for scope of work being done. E. Coordinate the electrical drawings with all other project drawings and trades prior to an rough-in. 2.1 Substitutions: A. Where Manufacturer's names appear, other Manufacturers may be substituted upon obtaining written approval of Engineer at least 10 days prior to opening of bids. B.Any prior approval of alternate equipment does not automatically exempt the supplier from meeting the intent of these specifications. Failure to comply with the operational and functional intent of these specifications may result in the total removal of the alternate system at the expense of the contractor. 3.1 Installation: A. Contractor shall visit the site and become acquainted with the conditions to be encountered. Extra funds will not be allowed due to failure to examine the site and include these conditions in the base bid price. B. Confirm dimensions, ratings, and specifications of equipment to be installed and coordinate these with site dimensions and with other Sections. C. Electrical drawings are diagrammatic. Do not scale for exact sizes or locations. Drawings are not intended to disclose absolute or unconditional knowledge of actual field conditions. D. Be prepared to relocate any outlet or device 6 feet in any direction without additional charge to the owner prior to wall, ceiling,or floor finish materials being installed. E. Install equipment according to manufacturer's recommendations. F. Provide electrical equipment for and make all connections to equipment furnished by others, including but not limited to items such as fire pumps, pools, kitchen equipment, medical equipment, etc. as required for a complete and operable system. 3.2 Field Quality Control: A. Test systems and demonstrate equipment as working and operating properly. Rectify defects at no additional cost to Owner. B. All work under this division shall be executed in a thorough workmanlike manner, as determined by the Engineer, by competent and experienced journeyman electricians C. All work shall be installed in strict conformance with all manufacturers requirements and recommendations. 3.3 Fire Stopping and Sealing: A. Seal around conduits or other wiring materials passing through fire rated walls in accordance with Architectural details and/or specifications. 3.4 Cutting and Patching A. Cut all openings required to install the work of this Division or to repair any defective work. Cost for all cutting and patching required by the work of this Division shall be included, however, the actual cutting and patching shall be under the Prime Contractor's direction.Exercise due dilligence to avoid cutting openings larger than required or openings that are in the wrong locations. B. It is the intent to minimize the amount of exposed conduit on the roof and penetrations through the roof. Install conduit below roof and up through the inside of the equipment where possible. In the event roof penetrations must be made, the conduit shall be installed through waterproof sheetmetal housings or water proof pitch pans as detailed on the drawings. 3.5 Identifications: A. Provide for each dimmer, panelboard, terminal cabinet, motor starter, motor controller, pushbutton, control switch, time clock, etc., furnished and/or installed under this Division of the Specifications, with identification as to its designation or specific function. Identification shall be a laminated, white core, black plastic nameplate with beveled edges. Lettering shall be machine- engraved, not less than 3/16 in. high, cut through the black surface to the white core. Secure nameplate to the identified item by the use of stainless steel self-tapping screws. Impressed plastic shall not be used to satisfy this requirement. Panel schedules shall be typed. 3.6 Guarantee-Warranty: A. Prior to final acceptance of the project deliver to the Owner a written one year guarantee on all workmanship, materials and equipment and agree to repair or replace all such defective items promptly that occur during this period. B. Guarantee work to be free from defects of materials and workmanship for a period of one year from date of final acceptance of building by authorities having jurisdiction. C. Furnish owner with three written copies of Guarantee-Warranty. 3.7 Clean-Up: A. Upon completion of the project, prior to final inspection, contractor shall thoroughly clean all exposed light fixtures, trim and equipment and leave the entire installation in a neat, clean and usable condition. Remove all cement, paint, grease, oil and any other foreign substances from all electrical devices, fixtures, and panels installed under this specification. 3.8 Testing: A. Contractor shall test all conductors for shorts, opens, grounds or other defects. Correct and/or replace any defective equipment, devices, conductors, light fixtures, etc. prior to final inspection. Demonstrate continuous and satisfactory operation of all electrical equipment and systems that where installed. END OF SECTION ELECTRICAL IDENTIFICATION 1.1 WORK INCLUDED A. Nameplates and labels. B. Wire and cable markers. 1.2 RELATED WORK A. This Section shall be used in conjunction with the following other specifications and related Contract Documents to establish the total requirements for electrical identification. 1. Basic Electrical Requirements B. In the event of conflict regarding electrical identification requirements between this Section and any other section, the provisions of this Section shall govern. 2.1 MATERIALS A. Nameplates: Engraved three-layer laminated plastic, minimum 3/16 inch high white letters on a black background. B. Nameplates (Emergency Equipment): Engraved three-layer laminated plastic, minimum 3/16 inch high white letters on a red background. C. Wire and Cable Markers: Split sleeve or tubing type. Cloth or wraparound adhesive types not approved. D. Conductor-color Tape: Colored vinyl electrical tape. 3.1 INSTALLATION A. Degrease and clean surfaces to receive nameplates. B. Install nameplates and labels parallel to equipment lines. C. Secure nameplates to equipment fronts. Secure nameplate to outside face of panelboard doors. D. Embossed tape will not be permitted for any application. E. Electrical Contractor shall write the circuit number to which each device is connected on the inside of the box (clearly visible when device is removed) and on the backside of each coverplate. Use a permanent black marker. 3.2 WIRE IDENTIFICATION A. Conductors for power circuits to be identified per the following schedule. System Voltage Conductor 480Y/277V 208Y/120V Phase A Brown Black Phase B Orange Red Phase C Yellow Blue Neutral Grey White Grounding Green Green Switchleg (lighting)Purple Pink 3.3 NAME PLATE ENGRAVING SCHEDULE A. Provide nameplates of minimum letter height as scheduled below. B. Panelboards, Switchboards and Motor Control Centers: 1. 1st Line -Equpment Name: 1/4 inch Lettering. 2. 2nd Line -Voltage Rating: 3/16 inch Lettering 3. 3rd Line -Feed Source: 3/16 inch Lettering 4. Nameplate Examples: PNL: HA SWBD: MSB 480Y/277V 480Y/277V FEED FROM: MSB-2 FEED FROM: UTIL. C.Individual Circuit Breakers, Enclosed Switches, and Motor Starters: 1. 1st Line -Load Served: 1/4 inch Lettering. 2. 2nd Line -Voltage Rating: 3/16 inch Lettering 3. 3rd Line -Feed Source: 3/16 inch Lettering 4. Nameplate Examples: FAN: F-1 480V-3P FEED FROM: HM-1,3,5 END OF SECTION RACEWAYS 2.1 Conduit: A.Minimum size is 1/2 inch unless indicated otherwise and use restricted as indicated by product. B. The conduit types shall be as follows, installed per locations and requirements of the NEC, these specifications and so installed: 1. RMC -Rigid Metal Conduit 2. IMC -Intermediate Metal Conduit 3. EMT -Electrical Metallic Tubing 4. Schedule 40 & 80 PVC (Underground use only) 5. LFMC -Liquidtight Flexible Metal Conduit 2.2 Fittings: A. Set-screw type with steel housing and insulated throat for EMT conduits B. Screw-in type for flexible metal conduit. C. Sealtite type for liquid-tight flexible metal conduit. D. Rigid & IMC conduit fittings shall be threaded and designed for conduit use. 2.3 Prohibited Materials: A. Rigid aluminum conduit. B. Crimp-on, tap-on, indenter type fittings. C. Malleable iron or cast set-screw fittings for EMT. D. Spray (aerosol) PVC cement. E. Type AC Cable F. Smurf Tube 3.1 Installation: A. Conceal raceways within ceilings, walls and floors except where exposed raceways are specifically permitted. B. Keep raceway runs 6 inches minimum from hot water pipes. C. Support conduit and boxes in an approved manner according to the NEC by - 1. Expansion shields in concrete or solid masonry. 2. Toggle bolts on hollow masonry units. 3. Wood screws on wood. 4. Metal screws on metal. D. Secure conduit with approved supports within 3 feet of every outlet box, junction box, gutter, panel, fitting, etc. Do not space supports further apart than 10 feet. E. Cap conduit ends during construction. F. Clean or replace conduits in which water or foreign matter have accumulated. G. Install insulated bushings on each end of conduit 1-1/4 inches in diameter and larger. H. Install grounding conductor in PVC conduit. I. Bending of PVC shall be by hot box J. Route exposed conduit and conduits installed above lay-in ceilings at righ angles or parallel to walls of building, not "as the crow flies". Neatly rack parallel conduits together and make bends uniform to one another. Where installation is made inferior utilizing poor practice contrary to these methods as determined by the Engineer, said installation will be removed and reinstalled at contractor's expense. K. Coat buried rigid or IMC conduit with approved asphaltic compound or wrap with two layers of approved corrosion protection tape. L. Leave one #10 or equivalent nylon pull wire in empty conduits. M. When PVC conduit is used, turn up with rigid galvanized elbows and provide equipment grounding conductor in accordance with NEC, Article 250. N. Cut and thread conduit so ends will butt in couplings. Make threads no longer than necessary and ream pipe free of burrs. O. All conduit that passes through a fire rated wall or floor shall use approved fire stops even if not shown on drawings. P. Provide all flex connections to all equipment and transformers. Seal-tite (LFMC) shall be used for all connections to motors, exterior equipment, and kitchen equipment. Q. Where conduits penetrate walls, ceilings and/or floors the contractor shall patch around conduit to form a tight seal and the surface around the conduit shall match the surrounding surface. R. Contractor shall furnish and install necessary roof jacks for all roof penetrations. 3.2 Prohibited Procedures: A. Use of wooden plugs inserted in concrete or masonry units as base for fastening conduits, tubing, boxes, cabinets, or other equipment. B. Installation of conduit or tubing which has been crushed or deformed. C. Torches for bending PVC conduit. D. PVC conduit inside of the building. END OF SECTION WIRES & CABLES 2.1 Applications: A. Service Entrance: Type XHHW or THWN, Copper conductors in raceway. B. Feeders: Type THHN, XHHW or THWN, Copper conductors in raceway. Minimum Size #4 AWG. C. Branch Circuits: 1. Type THHN, XHHW or THWN, Copper conductors in raceway. Minimum Size #12 AWG. D. Class 1 Control Circuits: Type THHN, XHHW or THWN, Copper conductors in raceway. Minimum Size #18 AWG. 2.2 Conductors: A. All wire shall be copper unless otherwise noted. B. All Conduit is sized for THW wiring. If contractor uses other than this it will be their responsibility to size conduit to meet NEC conduit fill requirements. C. Motor Circuits from the disconnect to the motor shall be type THW or XHHN stranded. D. #12 and #10 wire may be solid or stranded for lighting circuits, stranded only for power circuits. 2.3 Connectors: A. Type 512, 3M tapeless steel spring wire connectors or pressure type terminal lugs as specified. 3.1 Installation: A. Install conductors in raceway unless indicated otherwise. B. Pulling Conductors - 1. Do not pull conductors into conduit until raceway system is complete and cabinets and outlet boxes are free of foreign matter and moisture. 2. Do not use heavy mechanical means for pulling conductors. 3. Only wire pulling lubricant may be used. C. Conductors shall be continuous from outlet to outlet. D. Make splices for conductors No. 8 and smaller with steel spring wire connections. Splice larger conductors with Lock-Tite type silicon bronze type connectors. Insulate connections of No. 8 wire and larger with 3M #33 tape. E. Provide flexible conduit or cord sets for all equipment as required per that piece of equipment as determined by cutsheets and/or field conditions. F. Multi-wire Branch Circuits are NOT allowed. G. Individual branch circuits may be combine into a common raceway provided the de-rating factors of the NEC are met. H. Leave a minimum of 6" pigtail for all outlet and switch connections. I. Tag all feeder and branch circuit conductors in all enclosures, j-boxes, panels etc. to indicate the circuit and panel from which it is fed. END OF SECTION BOXES 1.1 General: A. All boxes shall be per NEC and sized per code based on the number of conductors entering and leaving each box. B. All boxes shall be a minimum of 1/5" deep, 4" x 4" square or octagonal when used with fixtures unless a larger box is required by the device or due to the number of conductors being installed in the boxed in order to meet fill capacity of the NEC. C. All boxes shall be pressed steel galvanized type, unless otherwise noted on the drawings. Boxes in masonry, block or tile walls shall be square corner type. 2.1 Outlet Boxes: A. Galvanized steel, and correct size and shape. B. Provide metal supports and other accessories for installation of each box. C. Equip ceiling and bracket fixture boxes with fixture studs where required. D. Equip outlets with extensions as required to bring box flush with finish surface. 3.1 Installation: A. Boxes shall be accessible and installed with approved cover. B. Sectional boxes shall not be used in concrete. C. Locate boxes so outlets are not obstructed by pipes, ducts, or other items. D. Install outlets flush or not more than 1/4 inch behind finished surface and level and plumb. E. Boxes for switches shall generally be located within 6 inches of door jamb. F. Color code emergency systems boxes in accordance with NEC and General Electrical Notes on drawings. G. Where boxes are located on opposite sides of fire or smoke rated wall assembly, separate boxes a minum of 24",or as otherwise required to maintain rating of wall. H. Identify all outlet, junction and pull boxes according to the system carried, by means of painted on stencils or labels with legible letters and contrasting colors and without abbreviations. END OF SECTION WIRING DEVICES 2.1 Switches and Receptacles: A. Switches shall be Specification grade, Color by Owner, rated 20A, 120-277V. B. Receptacles shall be Hospital grade, UL Tamper Resistant, Color by Owner, rated 20A, 120V. Mounted at 18" AFF in vertical position, unless otherwise noted. C. Color shall be same as plate. Verify color with architect before ordering devices. 2.3 Weatherproof Receptacles: A. GFCI type, Specification grade, color to match receptacles, rated 20A, 120V B. Provide weatherproof cover as required by the NEC. 2.4 Plates: A. Finished Spaces: Nylon, fiberglass, or high impact resistant plastic nylon, Color by Owner. The use of sectional type device plates are not permissible. B. Patient Rooms/Restrooms: Suicide Resistant; Securinghospitals.com p/n:812-S73-PCW C. Unfinished Spaces: Galvanized steel, surface-mounted boxes. D. Jumbo plates are not acceptable. 3.1 Installation: A. Provide proper size outlet boxes for all wiring devices of types specified in outlet and junction box section of these specifications. B. Receptacles shall be "pig-tailed" connected, so that a failure of a receptacle will not affect the remaining receptacles downstream. Utilizing the receptacle for in/out wiring is prohibited. C. Properly wire all convenience outlets so that the hot wire, the neutral wire and the ground wire connect to the proper terminal on all receptacles. D. Mount wall switches on lock side of doors not more than 12 inches from trim and in accordance with barrier free design standards. E. Provide GFI receptacles in areas required by the National Electrical Code whether indicated on the drawings or not. F. All devices shall be grounded per NEC. G. Where devices are located above counter tops, coordinate exact location with the millwork hop drawings prior to rough-in. END OF SECTION MOTORS, DISCONNECT SWITCHES AND FUSES 1.1 General: A. All motors and equipment shall have disconnecting means as dictated by the NEC even if not shown on the drawings. 2.1 Disconnects: A. Heavy duty quick-make, quick-break type, non-fused unless indicated otherwise on drawings. B. Fused disconnects shall be fused with dual-element time delay fuses (Class R) and be quipped wth rejection type use holders. C. or all motors and equipment size fuses per equipment manufacturer's nameplate rating. D. Disconnects for motor circuits shall be horsepower rated. E. Disconnects For Furnace Units -Provide manual starter with thermal overload relay. Provide overload relay to match motor full load amps. F. Enclosures shall be NEMA Type 1 or, where required to be weatherproof, NEMA Type 3R. G. Provide electrical interlock kit on disconnects serving equipment with variable frequency drives. H.Approved Manufacturers -Same as panelboards 3.1 Installation A. Label equipment, such as Fan Coil Unit FC-1. Label disconnects to indicate equipment served. Use 1/16 inch thick laminated plastic composition material with contrasting color core. Engraved letter shall be 1/4 inch high. Attach labels with screws. END OF SECTION GROUNDING 1.1 Summary: A. Includes But Not Limited To - 1. Furnish and install grounding for entire electrical installation as specified below and described in Contract Documents. a. Electrical service, its equipment and enclosures. b. Conduits and other conductor enclosures. c. Neutral or identified conductor of interior wiring system. d. Power and lighting panelboards. e. Non-current-carrying metal parts of fixed equipment such as motors, starter and controller cabinets, and lighting fixtures. 1.2 General: A. Provide all grounding as required by the NEC and Local Authority. 2.1 Components: A. Size materials as shown on Drawings and in accordance with applicable codes. B. Ground Conductors - Copper with green insulation or bare. C. Make grounding conductor connections to grounding electrodes and water pipes using approved bolted clamps of bronze or brass designed for such use. 3.1 Installation: A. Install a grounding electrode system at the service entrance equipment or location indicated on the Drawings, bond all grounding electrodes that are available as per NEC Section 250. B. Grounding connection to main water supply shall be accessible for inspection and made within 6 inches of point of entrance of water line to building or ahead of dielectric, if used, on meter side. C. Provide concrete-encased electrode system by embedding 20 feet minimum of #1/0 bare copper conductor in concrete footing, 2 inches minimum below concrete surface. Extend # 1/0 copper conductor to main panel as shown on Drawings. D. Ground identified grounded (neutral) conductor of electrical system on supply side of main service disconnect. E. Install a green equipment grounding conductor for all feeders and branch circuits, using the conduit as the grounding conductor is NOT acceptable. Use same size ground as phase conductors up through #10 AWG. Use NEC Table 250-122 for all others unless noted otherwise on Drawings. END OF SECTION LIGHTING 2.1 Lighting Fixtures: A. Lighting Fixtures - See Light Fixture Schedule. B. Provide plaster frames where required by ceiling construction. C. All recessed down lights shall be rated as follows, whether or not indicated on the fixture schedule: Rated T only if not in contact with any insulation materials. Rated IC when fixture is in contact with insulation materials. 2.2 WARRANTY A. LED Luminaires: Submit a warranty, mutually executed by the LED luminaire manufacturer and the installer, agreeing to replace LED luminaires that fail in materials or workmanship within five years, beginning on the date of substantial completion of project. 2.3 LED LUMINAIRES A. For LED lighting in interior spaces, use NRTL-listed 120V or 277V luminaires with the performance characteristics listed below: 1. Minimum luminaire efficacy per IES LM-79-08, Approved Method: Electrical and Photometric Measurement of Solid-State Lighting Products: a. 90 lumens/watt for general lighting, b. 50 lumens/watt for accent and display lighting, down-lighting, and special purpose lighting. 2. Correlated color temperature (CCT) per IES LM-79-08 and ANSI/NEMA/ANSLG 8.377-2008, Specification for the Chromaticity of Solid-State Lighting (SSL) products: a. as indicated in fixture schedule 3. Color rendering index (CRI): 90 or better per IES LM-79-08. 4. LED Design life (L70): Not less than 50,000 hours per IES LM-80-08, Approved Method: Measuring Lumen Maintenance of LED Light Sources. 5. Driver System Design Life: Not less than the LED design life; note that the driver system includes all associated components, not just the driver integrated circuit. Driver system design life is defined as when 2 percent of the systems would have failed. 6. Power factor: 0.90 or better. 7. Design ambient temperature: 35 °C (95 °F); note that this is the ambient temperature surrounding the luminaire, not the LED or driver heat-sink temperature. 8. EMI/RFI: Meet FCC 47 CFR Part 15. 9. Minimum dimming provisions or capability: a. 50% step for general lighting, b. Down to 20% for accent and display lighting, and special purpose lighting. 3.1 Installation: A.Mount fixtures as called for on drawings. Determine type of ceiling being installed in each space and furnish fixtures suitable for exact type, including roof/floor or ceiling/floor fire rated design with fire tenting required by Architect. All coordination and materials to be provided without additional cost to owner. B. If a recessed fixture is installed in a fire rated ceiling, provide a fire rated enclosure around the fixture to maintain the ceilings fire rating. C. All light fixtures shall be supported from the building structure. D. Fixtures shall be installed per NEC. E. Securely fasten fixtures to structural members. Support fixtures mounted in ceilings and attach to ceiling system as required by NEC 410-16(c). Provide four seismic support cables on all troffer fixtures. F. Coordinate fixture locations to clear diffusers, ductwork, piping, building structure, etc. without additional cost to owner. G. Support surface-mounted fixtures from building structural system using rods in conjunction with clamps or fixture outlet boxes. Provide additional support equal to seismic fixture mounting detail on drawings. H. Support plaster or drywall mounted fixtures from support channels spanning across main building supports without depending on ceiling system for support. Provide support equal to seismic fixture mounting detail on drawings I. At completion of the project, all fixtures shall be clean and free of breaks and defects with all lamps operating. J. Install emergency lighting pack in ballast channel with charging indicator light and test swtch mounted on fixture end, or visible and accessible through lens. K. Wire emergency battery packs so units can be tested with lights on. L. Wire emergency battey packs so lamps in normal mode are switched off with other lighting in area. Connect emergency lighting unit to unswitched conductor of normal lighting circuit. END OF SECTION TELEPHONE/DATA SYSTEMS 1.1 Summary A.Includes But Not Limited To 1. Furnish and install all the equipment, materials, terminations and labor necessary to provide a complete CAT6 Telephone/Data and Television cabling system as described in Contract Documents including, but not limited to, raceway, outlets, modular jacks, device plates, cables, punch down blocks, backboards, cabinets, patch panels, grounding and other miscellaneous items required for a complete system. 2. Furnish and install main service raceway as described in Contract Documents and to comply with local telephone company requirements. 3. Refer to Drawings for conduit sizes and quantity of cables/jacks at each outlet location. 1.2 Warranty A.A Lifetime product warranty covering all components, equipment and workmanship shall be submitted in writing with system documentation. The warranty period shall begin on the system's first use by the owner. Warranty shall be vendor supplied. Contractor warranty alone is unacceptable. B.The project must be pre-registered with Manufacturer before installation has begun. 2.1 Components A.Boxes shall be a 4 square deep box with single-gang mudring. B.Telephone and Computer Network System Cable 1. 23 gauge, solid annealed copper, 4-pairs. CAT6 2. Use plenum-rated cable in ceilings and areas used for plenum air return 3. Provide Owner with patch panels, quantity as required. 4. Different colors of cabling shall be used; (Yellow -Telephone, Blue - Network) 5. Manufacturers: a. Superior Essex b. Alternate manufacturer with equivalent performance standard. C.Equipment Racks 1. Provide a minimum of (1) 19" wall mounted rack at each TTB location 2. Provide with 20A power strip, wire management and rack mounting kits. 3. Manufacturers: a. Cooper B-line b. Alternate manufacturer with equivalent performance standard. D.Telephone Termination Blocks 1. UL verified CAT6. 2. 66 termination with tin lead plated IDC E.Telephone & Network Patch Panels 1. UL verified CAT6 2. 110 termination with tin lead plated IDC 3. 19" rack mount with backboard mounting frame. 4. 48 Ports 5. Manufacturers: a. Leviton b. Alternate manufacturer with equivalent performance standard. F.Telephone/Network Jacks & Faceplates 1. Wall Jacks a. CAT6 -Color to match cable color. 2. Faceplates a. Color to be as specified by Owner. b. Provide and install Blank inserts as needed. 3. Manufacturers: a. Leviton b. Alternate manufacturer with equivalent performance standard. G.Television Cabling, Jacks & Equipment 1. Cabling: RG6 cable, 75 Ohm 2. Terminate Cable on both ends using an ICM digital F-type Connector. 3. Faceplate color to be as specified by Owner. 4. Terminate all cabling on a Levition# 49255-H48 Multimedia patch panel (with F-Type connector). Install patch panel in nearest rack. 3.1 Installation A.Cables shall be installed in conduit from outlet to above nearest accessible ceiling space, install J-hooks above accessible ceiling space 3ft on center for supporting cable. Install cable from terminal board/data rack to each telephone/network outlet. B.Terminate cables at each outlet with specified modular jack assembly. C.Terminate cables on punch down blocks or patch panels at terminal board. D.All Faceplates, patch panels and cables shall be labeled depicting location, Cables shall be labeled on both ends. E.Terminate cabling according to EIA/TIA 568B.1 Standards. F.Installation of all materials shall be as recommended by manufacturer. 3.2 Quality Assurance A.Comply with applicable portions of NEC ANSI/EIA/TIA 568 as to type products used and installation of components. Provide products and materials which have been UL-listed and labeled. B.Cabling system shall meet the performance requirements of the ANSI/TIA/EIA-568-B Standards (Annex E). C.Each cable and patch cable shall be tested from the outlet location to the patch panel, the system shall be tested to Category 6 Level II compliance. The test path shall include workstation jacks, Horizontal cabling and patch panels. Contractor shall replace any equipment or cabling that fails and retest. Provide Owner with complete test reports of cabling system. END OF SECTION 13053 ST ATE OF I D A HOSHAWNA.M E A D O R R E G I S TEREDRPOFESSIONALENGIN E E R Engineering Inc. Consulting Engineers1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Street Pocatello, Idaho 83201 (208) 233-0501 Fax (208) 233-0529 Checked By: Plot Date: Consultants: Drawing Number: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D BRP SAM P.E. JOB #2067 RE X B U R G , ID A H O ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 East Center Street Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 9/30/20 10/12/2020 9:01:37 AM E5.2 EL E C T R I C A L S P E C I F I C A T I O N S 778 BE H A V I O R H E A L T H SEPT 2020 MA D I S O N M E M O R I A L H O S P I T A L