HomeMy WebLinkAboutPLANS APPROVED - 20-00977 - Cal Ranch Interior - RemodelAuthor Name Author Email Author Phone No.: Bret Stoddard brets@rexburg.org 208-372-2171 Don Allen Don.Allen@rexburg.org 208-372-2174 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Cal Ranch Interior - Remodel Address : 530 N 2nd E Record Type : Commercial - Remodel Document Filename : 20-18 - Cal Ranch Rexburg - 100% C.D.'S - 2020-12-30.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 20-00977 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments AD101 - DEMOLITION FLOOR PLAN Comment Cody Jones : Building Open 13 Existing ramps if not already will need to be in compliance. AD101 - DEMOLITION FLOOR PLAN Comment Cody Jones : Building Open 13 Any penetrations through seperation wall will need to be fire sealed. Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:03:08 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOCOVER SHEETG00014 DECEMBER, 202020-18DBNDBNCAL RANCH REXBURG TBO530 N. 2ND EAST- SOUTH SUITEREXBURG, IDAHO14 DECEMBER, 2020100% CONSTRUCTION SETENGINEERINGCONSULTANTSMECHANICAL / PLUMBINGROYAL ENGINEERINGMICHAEL R. BEAGLES, P.E. MANUEL MASBERNAT, P.M.1837 S. EAST BAY BLVD.PROVO, UT 84606O: (801) 375-2228BIDDING INFORMATIONTHESE DOCUMENTS ARE INTENDED FOR PROJECT NEGOTIATION BETWEEN A SINGLE GENERAL CONTRACTOR AND OWNER. THESE DOCUMENTS ARE NOT INTENDED TO BE USED FOR COMPETITIVE BIDDING BY MULTIPLE GENERAL CONTRACTORS.THE ARCHITECT WILL CLARIFY INFORMATION WITHIN THESE DOCUMENTS FOR A SINGLE OWNER-SELECTED GENERAL CONTRACTOR ONLY. REQUESTS FOR CLARIFICATION SHALL BE DIRECTED TO CURTIS MINER ARCHITECTURE BY THE GENERAL CONTRACTOR. CALLS FROM SUBCONTRACTORS WILL BE REFERRED TO THE GENERAL CONTRACTOR.MATERIALS LEGENDEARTHGRAVELCONCRETERIGID INSULATIONCONCRETE MASONRY UNITSTEEL DECKWOOD BLOCKINGCONTINUOUS WOOD MEMBERMETALWOOD STUD WALLSCONTINUOUS METAL STUDBATT INSULATIONFINISHED WOOD MEMBERGLASSDIMENSION NOTES1. ALL PLAN DIMENSIONS, UNLESS OTHERWISE NOTED, ARE TO:A. COLUMN GRID ON CENTERLINES.B. THE OUTER FACE OF CONCRETE OR MASONRY.C. THE FINISHED FACE OF WALL.2. DOOR LOCATIONS NOT DIMENSIONED ARE:A. JAMB FACE 4" FROM FACE OF STUD.B. CENTERLINE OF DOOR ON CENTERLINE OF DOOR OR CORRIDOR.3. NOTED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE DIMENSIONS; DETAILS OVER SMALLER SCALE DRAWINGS.4. "FLOOR LINE" REFERS TO TOP OF CONCRETE SLABS. FOR DEPRESSED FLOORS AND CURBS, SEE STRUCTURAL DRAWINGS.5. VERIFY ALL ROUGH-IN, CONCRETE PAD, OR PLATFORM DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS PROJECT, OR BY OTHERS.6. FINISHED FLOOR ELEVATIONS ARE TO TOP OF CONCRETE OR GYPCRETE, UNLESS NOTED OTHERWISE.7. CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES, UNLESS NOTED OTHERWISE.INDEX OF DRAWINGSEQUIPMENT NUMBERSHEET NOTEXGLAZINGXWALL TYPESXWINDOWXXXDOORX'-XX"XCEILING TAGAXXXXXXXXXXXXXAXXXXXAXXXDETAIL NUMBERSHEET ON WHICHDETAIL OCCURSDETAILNUMBERSHEET ON WHICHSECTION OCCURSWALL SECTIONELEVATIONSHEET ON WHICHELEVATION IS SHOWNSYMBOLSMATCHLINESEE DWGMATCHLINELEVEL ELEVATIONADA CLEAR DISTANCEADA CLEAR DISTANCEWORK POINT or ELEVATION MARK GRID LINESXXAXXXAXXXXXXXAXXXNUMBERSHEET ON WHICHSECTION OCCURSOVERALL BUILDING SECTIONELEVATION NUMBERSHEET ON WHICHELEVATION OCCURSELEVATIONXXA1XXSYMBOLSXXELEVATIONxxxxxxxTRANSITION STRIP TAGWALL & BASE FINISH SPECIFIC W?,B?TS-?ARCHITECTURALG000 COVER SHEETG001 CODE & ACCESSIBILITY COMPLIANCEAD101 DEMOLITION FLOOR PLANA101 NEW FLOOR PLAN - OVERALLA101A NEW FLOORPLAN - AREA AA101B NEW FLOORPLAN - AREA BA101C NEW FLOORPLAN - AREA CAA102 NEW ROOF PLANA151 NEW REFLECTED CEILING PLANA201 EXTERIOR ELEVATIONSA251 INTERIOR ELEVATIONSA301 WALL SECTIONSA302 3-D VIEWSA601 DOOR TYPES & DETAILSAI101 INTERIOR FINISHESELECTRICALROYAL ENGINEERINGMARK L. MAKIN, P.E.CHRIS FALSLEV, P.M.1837 S. EAST BAY BLVD.PROVO, UT 84606o: (801) 375-2228DEFERRED SUBMITTALDEFERRED SUBMITTALS ARE TO BE MADE IN COMPLIANCE WITH SECTION 107.3.4.1 OF THE 2015 INTERNATIONAL BUILDING CODE. THE FOLLOWING DESIGN SHALL BE BY DEFERRED SUBMITTAL: FIRE SPRINKLER DESIGN.STRUCTURALS101 STRUCTURAL PLANS & DETAILSMECHANICALM0.1 MECHANICAL NOTES AND LEGENDSM1.1 MECHANICAL DEMO PLANM1.2 MAIN FLOOR MECHANICAL PLANM5.1 MECHANICAL DETAILSM6.1 MECHANICAL SCHEDULESM7.1 MECHANICAL SPECIFICATIONSM7.2 MECHANICAL SPECIFICATIONSM7.3 MECHANICAL SPECIFICATIONSPLUMBINGP0.1 PLUMBING NOTES AND LEGENDSP1.1 PLUMBING DEMO PLANP1.2 MAIN FLOOR PLUMBING PLANP5.1 PLUMBING DETAILSP5.2 PLUMBING DETAILSP6.1 PLUMBING SCHEDULES AND SCHEMATICSP7.1 PLUMBING SPECIFICATIONSP7.2 PLUMBING SPECIFICATIONSELECTRICALE0.0 ELECTRICAL COVER SHEETE1.1 SITE ELECTRICAL PLANE2.1 LIGHTING PLANE3.1 POWER PLANE6.1 ELECTRICAL SCHEDULESE6.2 ELECTRICAL SCHEDULESE7.1 ELECTRICAL DETAILSE7.2 ELECTRICAL DETAILSE8.1 ELECTRICAL SPECIFICATIONSJAY ADAMS, P.E.DYNAMIC STRUCTURESSTRUCTURAL2018/1/162018/9/292020/3/172020/8/312020-12-1430 DECEMBER, 2020 ADA TACTILESIGNAGEDUPLEXOUTLETDUPLEXOUTLETSWITCHTHERMOSTATFIREEXTINGUISHERMAX4'-0"MAX4'-0"16" MINMAX5'-0"MIN4'-0"CONTROL PANELB2468"*1S357*MIN2'-11"MAX4'-0"SWITCHRECEPTACLEGFCI RECEPTACLE4'-0" MAX.; 3'-8" IFCOUNTER ISLESS THAN 20"DEEP; 3'-6" FORACCESSIBLELIGHT FIXTUREMIRRORGFCIRECEPTACLEKITCHENBATHROOMLAVATORYGFCIRECEPTACLEBASEMENT,LAUNDRY,UTILITY ROOMMIN2 1/2"MAX.4' - 0"MIN1' - 6"MAX4' - 0"7' - 0"3' - 6"(4'-0" IN GARAGES)34" MAXDESIGN CRITERIABUILDING SIZE: OVERALL EXISTING BUILDING: 92,107 S.F.REMODEL AREAS:CAL RANCH TBO AREAS: 76,192 S.F.EXISTING HARBOR FREIGHT TBO: 15,915 S.F.TOTAL: 92,107 S.F.CODE EVALUATIONBUILDING CODE: 2015 INTERNATIONAL BUILDING CODE.2017 NATIONAL ELECTRICAL CODE.2015 INTERNATIONAL MECHANICAL CODE.2015 INTERNATIONAL ENERGY CONSERVATION CODE.ICCA117.1-2009.2015 EXISTING BUILDING CODE2015 FUEL GAS CODE2017 IDAHO PLUMBING CODE2015 INTERNATIONAL FIRE CODE.OCCUPANCY CLASSIFICATION: M (MERCANTILE) NO CHANGEOCCUPANCY REQUIREMENTS: M (IBC 304.1) NO CHANGETYPE OF CONSTRUCTION: 2-B (IBC TABLE 503)OCCUPANT LOAD: (IBC TABLE 1004.1.2)CAL RANCH TBO AREAS: 76,192 S.F. / 85 S.F. (EST.) = 897 OCCUPANTS (EST.)EXISTING HARBOR FREIGHT: 10,074 S.F. / 60 GROSS = 167.9 OCCUPANTS5,841 S.F. / 300 GROSS = 19.5 OCCUPANTS 188 OCCUPANTS 1,085 OCCUPANTS (ESTIMATED)ASCALE: 3/4" = 1'-0"WALL TYPEBSCALE: 3/4" = 1'-0"WALL TYPE5/8" TYPE 'X' GYPSUM BOARD -PAINTED3 5/8" 24 GAUGE METAL STUDS @ 16" O.C. 1/2" DENSGLASS SHEATHING6" METAL STUDS. SEE STRUCTURAL FOR SPACING AND GAUGECSCALE: 3/4" = 1'-0"WALL TYPESYNTHETIC STONE VENEER SYSTEMFLUID APPLIED VAPOR BARRIERUL U4655/8" TYPE 'X' GYPSUM BOARD -PAINTED3 5/8" 24 GAUGE METAL STUDS @ 16" O.C. R-13 BATT INSULATION5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:02:24 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOCODE & ACCESSIBILITYCOMPLIANCE & WALL TYPESG00114 DECEMBER, 202020-18DBNDBNSCALE:1/4" = 1'-0"G001TYPICAL ACCESSORY HEIGHTSA4SCALE:1/4" = 1'-0"G001TYPICAL ACCESSORY HEIGHTSA22018/1/162018/9/292020/8/312020-12-14 GENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THEARCHITECT.B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES.C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS.PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS.D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL E. SEE SHEET A151 FOR REFLECTED CEILING PLAN INFORMATION..F. SEE A601 FOR DOOR INFORMATION.G. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHERARCHITECTURAL GENERAL INFORMATION.H. DO NOT SCALE DRAWINGS.1010332211FFBB445566CCDD261'-8"JJHHGG30'-4" 42'-10" 35'-0" 43'-10" 30'-10" 32'-2" 46'-0"EE28'-5" 40'-6" 40'-6" 43'-0" 41'-3" 40'-10" 39'-3" 39'-3" 38'-2"778899352'-0"EXISTINGHARBORFREIGHTSUITE 4RAMPRAMP26'-0" 60'-0"266'-0"D3A301ELEC (EX)111RISER (EX)112A112D4A30111AA15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 2'-0" 8'-0" 40'-0" 8'-0" 2'-0" 15'-0" 15'-0" 4'-8"3'-0"F.V.10'-0"3'-0"D1A301A201D1JAN. (EX.)EX.EX.EX.EX.EX.HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105VESTIBULE100AADADRESSING103DRESSING102SALESFLOOR - A101OUTDOORYARD115I.T.113A201C31'-4"FIELD VERIFY37'-4" 1'-4"SALESFLOOR - C114SALESFLOOR - B104A201C1D1A301CARTS100BA251C55ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 7:58:30 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHONEW FLOOR PLAN - OVERALLA10114 DECEMBER, 202020-18DBNDBNSCALE:1/16" = 1'-0"A101D1NEW FLOOR PLAN - OVERALLN99%12018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 1010FFBB445566CCDDEE778899A201D1D3A301D4A30130'-4"42'-10"35'-0"43'-10"43'-0"41'-3"40'-10"39'-3"39'-3"38'-2"12'-6" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 2'-0" 8'-0" 40'-0" 8'-0" 2'-0" 15'-0" 15'-0" 4'-8"229'-8"3'-0"F.V.10'-0"3'-0"D1A301101DVESTIBULE100A100BADADRESSING103DRESSING102SALESFLOOR - A101OUTDOORSALES 2100BOUTDOORSALES 1100AFIELD VERIFY37'-4" X 10'-0" R.O.100A100C12'-5"FIELD VERIFY37'-4" X 10'-0" R.O.CALL BUTTON1021035'-5"7'-4 1/2"7'-5"6"B6"BB+10'+10'+10'+10'BB17'-6"2'-0"15'-6"CARTS100BAADECKDECKDECKA201C3100DBBAABOVE, DECKAABOVE, DECKAABOVE, DECKA251D4D518'-6"15'-6"3'-0"13'-6"2'-6" 8'-6" 2'-6"A251D5SIM.OPP.1112222222233334444899111011141414141414CCCCCC15151516SHEET NOTES1. EXISTING BUILDING SHELL WALLS, DOORS, FLOORS, ETC. TO REMAIN.2. STORE FIXTURES BY TENANT. PROVIDE POWER WHERE SHOWN ON ELEC.3. NEW AUTOMATIC SLIDING DOOR SYSTEM. SEE A601. PROVIDE POWER4. FIRE EXTINGUISHER, 2A10BC5. EXISTING FIRE RISER & FDC. RECONFIGURE AS REQUIRED. SEE PLUMBING6. NEW MDP LOCATION. SEE ELECTRICAL.7. NEW ELECTRICAL EQUIPMENT, SEE ELEC.8. NEW 18" WIDE PLASTIC LAMINATE BENCH WITH FIRE TREATED 3/4" PLYWOOD AND 3 5/8" 18 GA. METAL STUD STRUCTURE, 18" A.F.F9. STAINLESS STEEL CLOTHES HOOK, 48" A.F.F10. PLASTIC LAMINATE MILLWORK. SEE A25111. EQUIPMENT BY OWNER12. DEMOLISH EXISTING FLOORING, GRIND AND POLISH EXPOSED CONCRETE FLOORS.13. 6' CHAIN LINK FENCING WITH BARBED WIRE AT TOP, GATES AS SHOWN.14. STEEL COLUMNS. PRIMED & PAINTED. SEE STRUCTURAL.15. NEW DOOR. SEE A60116. EXISTING COLUMN.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 7:58:31 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHONEW FLOORPLAN - AREA AA101A14 DECEMBER, 202020-18DBNDBNSCALE:1/8" = 1'-0"A101AE1NEW FLOOR PLAN - AREA A - WESTN2018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 1010FF445566JJHHGG77889930'-10"32'-2"46'-0"43'-0"41'-3"40'-10"39'-3"39'-3"38'-2"RISER (EX)112112AAGUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105SALESFLOOR - A101A105A105B9'-0"54'-6"CLEAR5'-0" 9'-2"129'-0 1/2"AAADECKDECKDECKADECKDECKRR(EX)RR(EX)JAN.(EX)RR(EX)RR(EX)ADECKBDECKAAAAADECKADECK11014'-8" 11'-2" 11'-0" 18'-0" 8'-4 1/2"109107HALL10710817'-0"10'-0"6'-2"CLEAR5'-0"11'-6"9'-8"ADECKI.T.113113ADECK7'-8" 25'-3 1/2" 8'-5 1/2"1063'-3" 15'-1" 6'-7"106ADECKADECKAADECKADECKA251C5444244442111ADECKDECKADECK222215761011111115151515151515GENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THEARCHITECT.B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES.C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS.PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS.D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL E. SEE SHEET A151 FOR REFLECTED CEILING PLAN INFORMATION..F. SEE A601 FOR DOOR INFORMATION.G. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHERARCHITECTURAL GENERAL INFORMATION.H. DO NOT SCALE DRAWINGS.SHEET NOTES1. EXISTING BUILDING SHELL WALLS, DOORS, FLOORS, ETC. TO REMAIN.2. STORE FIXTURES BY TENANT. PROVIDE POWER WHERE SHOWN ON ELEC.3. NEW AUTOMATIC SLIDING DOOR SYSTEM. SEE A601. PROVIDE POWER4. FIRE EXTINGUISHER, 2A10BC5. EXISTING FIRE RISER & FDC. RECONFIGURE AS REQUIRED. SEE PLUMBING6. NEW MDP LOCATION. SEE ELECTRICAL.7. NEW ELECTRICAL EQUIPMENT, SEE ELEC.8. NEW 18" WIDE PLASTIC LAMINATE BENCH WITH FIRE TREATED 3/4" PLYWOOD AND 3 5/8" 18 GA. METAL STUD STRUCTURE, 18" A.F.F9. STAINLESS STEEL CLOTHES HOOK, 48" A.F.F10. PLASTIC LAMINATE MILLWORK. SEE A25111. EQUIPMENT BY OWNER12. DEMOLISH EXISTING FLOORING, GRIND AND POLISH EXPOSED CONCRETE FLOORS.13. 6' CHAIN LINK FENCING WITH BARBED WIRE AT TOP, GATES AS SHOWN.14. STEEL COLUMNS. PRIMED & PAINTED. SEE STRUCTURAL.15. NEW DOOR. SEE A60116. EXISTING COLUMN.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 7:58:33 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHONEW FLOOR PLAN - AREA BA101B14 DECEMBER, 202020-18DBNDBNSCALE:1/8" = 1'-0"A101BE1NEW FLOORPLAN - AREA B - SOUTHN2018/1/162018/9/292020/8/312020-12-14 332211FF44JJHHGG30'-10"32'-2"46'-0"28'-5"40'-6"40'-6"RISER (EX)112112AAOUTDOORYARD115114A15'-4"10'-0"56'-0"6'-4"28'-7"SALESFLOOR - C114114BI.T.113AAA58'-0"20'-0"3'-0"55'-0"56'-0"4422DECK17'-0"9'-7"6'-2"6'-4 1/2" 14'-8"DECKDECK115111113131313SHEET NOTES1. EXISTING BUILDING SHELL WALLS, DOORS, FLOORS, ETC. TO REMAIN.2. STORE FIXTURES BY TENANT. PROVIDE POWER WHERE SHOWN ON ELEC.3. NEW AUTOMATIC SLIDING DOOR SYSTEM. SEE A601. PROVIDE POWER4. FIRE EXTINGUISHER, 2A10BC5. EXISTING FIRE RISER & FDC. RECONFIGURE AS REQUIRED. SEE PLUMBING6. NEW MDP LOCATION. SEE ELECTRICAL.7. NEW ELECTRICAL EQUIPMENT, SEE ELEC.8. NEW 18" WIDE PLASTIC LAMINATE BENCH WITH FIRE TREATED 3/4" PLYWOOD AND 3 5/8" 18 GA. METAL STUD STRUCTURE, 18" A.F.F9. STAINLESS STEEL CLOTHES HOOK, 48" A.F.F10. PLASTIC LAMINATE MILLWORK. SEE A25111. EQUIPMENT BY OWNER12. DEMOLISH EXISTING FLOORING, GRIND AND POLISH EXPOSED CONCRETE FLOORS.13. 6' CHAIN LINK FENCING WITH BARBED WIRE AT TOP, GATES AS SHOWN.14. STEEL COLUMNS. PRIMED & PAINTED. SEE STRUCTURAL.15. NEW DOOR. SEE A60116. EXISTING COLUMN.GENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THEARCHITECT.B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES.C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS.PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS.D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL E. SEE SHEET A151 FOR REFLECTED CEILING PLAN INFORMATION..F. SEE A601 FOR DOOR INFORMATION.G. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHERARCHITECTURAL GENERAL INFORMATION.H. DO NOT SCALE DRAWINGS.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 7:58:34 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHONEW FLOORPLAN - AREA CA101C14 DECEMBER, 202020-18DBNDBNSCALE:1/8" = 1'-0"A101CE1NEW FLOOR PLAN - AREA CN2018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 ACEILING LEGEND BOPEN CEILING TO STRUCTURE ABOVE. PAINT ALL STRUCTURE, DUCTWORK PIPING, ETC. MASK OFF SENSITIVE COMPONENTS.2x4 GRID CEILING, USG FROST CLIMA PLUS OR EQUIVELANT. 15/16" T GRIDCEXISTING TO REMAINDEXPOSED WOOD STRUCTURE, STAINED & SEALEDEALUMINUM SOFFITGENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS,AND ASSEMBLIES PRIOR TO CONSTRUCTION. REPORT ANY SIGNIFICANTDISCREPANCIES TO THE ARCHITECT.B. CEILING HEIGHTS SHOWN ARE ABOVE FINISH FLOOR IN WHICH THEYARE CALLED.C. COORDINATE LOCATION OF MECHANICAL EQUIPMENTD. FIRE SPRINKLER SYSTEM TO BE RECONFIGURED AS REQUIRED PER NFPA 13.E. DO NOT SCALE DRAWINGS.SHEET NOTES1. INSTALL NEW R-38 BATT INSULATION WITH WHITE PLASTIC SCRIM COVERING PULLED TIGHT. PAINT ALL REMAINING EXPOSED ROOF STRUCTURE, PIPING, DUCTWORK, ETC. WHITE. 2. RECONFIGURE FIRE SPRINKLER SYSTEM, TURN HEADS UP FOR NEW OPEN CEILING STRUCTURE.3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR NEW LIGHTING AND DUCTWORK DESIGN4. INSTALL BIRD SPIKES ON ALL SURFACES. 1010332211FFBB445566CCDDJJHHGGEE778899D3A301D4A301TYP.33D1A301EXISTING, NOT IN SCOPEA10'-0"A10'-0"A10'-0"A10'-0"EXISTINGEXISTINGEXISTINGEX. EX.EX.EX.EX.OPENBOPENBOPENBOPENBOPENCOPENBOPENBA10'-0"A10'-0"VARIESDVARIESDVARIESD10'-0"E28'-5" 40'-6" 40'-6" 43'-0" 41'-3" 40'-10" 39'-3" 39'-3" 38'-2"351'-2"30'-4"42'-10"35'-0"43'-10"30'-10"32'-2"46'-0"261'-0"4444OPENOPEN5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 7:58:38 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHONEW REFLECTED CEILING PLANA15114 DECEMBER, 202020-18DBNDBNSCALE:1/16" = 1'-0"A151E1REFLECTED CEILING PLANNOTE: THE EXISTING FIRE SPRINKLER SYSTEM SHALL BE RECONFIGURED AS REQUIRED PER NFPA 13 AS A DEFERRED SUBMITTAL BY THE GENERAL CONTRACTOR.N12018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXIST127'-0"T.O. PARAPET - LOW10456789D3A301129'-0"T.O. PARAPET - HIGHD4A301139'-0"8'-0" 40'-0" 8'-0" 36'-8"4'-8"15'-0"15'-0"2'-0"8'-0"40'-0"8'-0"2'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"15'-0"2'-0"7'-2"10'-0"D1A3016'-2"17'-2"2'-0"14'-0"3'-2"10'-0"148844444889P-1P-1P-1P-1100'-0"FINISHED FLOORBC129'-0"T.O. PARAPET - HIGHNEW EIFS TRIM WITH NEW PARAPET CAPEXISTING BUILDINGHORIZONTAL BEAM AT (4) END LOCATIONS ONLYNEW SYNTHETIC STONE FINISHSTANDING SEAM METAL ROOF OVER 5/8" PLYWOOD OVER 2X10@ 24" O.C.STEEL COLUMN. SEE STRUCTURAL. CONCRETE PIER SEE STRUCTURAL INSTALL BIRD SPIKES10'-0"12'-0"EXTERIOR MATERIAL LEGENDEF-1EIFS, LIGHT TAN - COLOR TO MATCH "CAL RANCH TAN". VERIFY WITH CAL RANCH.P-1EXISTING CMU WITH NEW PAINT FINISH. USE BLOCK FILLER AT NEWLY EXPOSED AREAS. COLOR TO MATCH "CAL RANCH TAN". VERIFY WITH CAL RANCH.EF-2EIFS, DARK BROWN - COLOR TO MATCH SHERWIN WILLIAMS 6076 TURKISH COFFEE. VERIFY WITH CAL RANCH.S-1SYNTHETIC STONE, HARRISTONE, "BROWN CHIEF JOSEPH". VERIFY WITH CAL RANCH.P-2PRIMED & PAINTED METAL. S.W. 6076 TURKISH COFFEE, HIGH PERFORMANCE COATINGR-1PRE-FINISHED METAL ROOFIN, PARAPET CAP, FASCIA, SOFFIT. MATCH S.W. 6076 TURKISH COFFEESHEET NOTES - ELEVATIONS1. PREFINISHED ALUMINUM STOREFRONT DOOR SYSTEM WITH THERMAL BREAKS. SEE DOOR AND WINDOW TYPES.2. EIFS FINISH3. PRE-FINISHED METAL PARAPET WALL CAP. SEE DETAIL B6/A501.4. TUBE STEEL, PRIMED & PAINTED. SEE STRUCTURAL.5. CMU INFILL. SEE STRUCTURAL.6. METAL DOOR, GALVANIZED, PAINTED, INSULATED. 3'-0" X 7'-4" R.O.7. 10' X 10' X 3/4" PLYWOOD BACKING BEHIND EIFS FINISH PANEL FOR SIGNAGE CONNECTION.8. NEW STANDING SEAM METAL ROOF OVER NEW STRUCTURE9. NEW CONTINUOUS RAINGUTTERS WITH DOWNSPOUTS LOCATED AT COLUMNS.GENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS, AND ASSEMBLIES PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ARCHITECT.B. ALL MASONRY WALLS TO HAVE CONTROL JOINTS AT 30'-0" O.C. MAXIMUM. VERIFY WITH STRUCTURAL.C. EXPOSED CONCRETE FOUNDATION AND RETAINING WALLS TO RECEIVE RUBBED FINISH.D. PROVIDE PRE-FINISHED NUMBERS ON THE FRONT, EXTERIOR OF THE BUILDING INDICATING THE BUILDING ADDRESS NUMBER ASSIGNED BY THE CITY IN ACCORDANCE WITH CURRENT CITY ORDINANCE. COLOR OF PRE-FINISHED NUMBERS TO CONTRAST SIGNIFICANTLY WITH BACKGROUND COLOR OF EXTERIOR WALL. THAT ADDRESS MUST BE PERMANENTLY FASTENED TO THE EXTERIOR OF THE BUILDING PRIOR TO OCCUPANCY.E. EXTERIOR SIGNAGE: THE OWNER IS RESPONSIBLE TO OBTAIN A SEPARATE PERMIT FOR ANY EXTERIOR SIGNS IN ACCORDANCE WITH CURRENT CITY SIGN ORDINANCE. THE OWNER IS RESPONSIBLE TO CONTRACT DIRECTLY WITH SIGN VENDORS. SIGN VENDORS SHALL INSTALL THEIR RESPECTIVE SIGNAGE. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE AND COORDINATE ALL BACKING AND POWER REQUIREMENTS FOR EACH SIGN.F. NOT ALL SHEET NOTES ARE NECESSARILY USED ON EACH SHEET.123'-4"T.O. PARAPET - EXIST127'-0"T.O. PARAPET - LOW89D3A301129'-0"T.O. PARAPET - HIGHD4A3018'-0"40'-0"8'-0"2'-0"8'-0"40'-0"8'-0"2'-0"7'-2"10'-0"17'-2"10'-3" 2'-6" 14'-6" 2'-6" 10'-3" 1 3 5 °135°14'-0"3'-1 1/2"10'-0"18'-0"1'-0"9"8 1/2"EF-1EF-1EF-2EF-2R-1R-1P-2P-2R-1EF-1EF-1S-1S-1P-1P-1P-1P-11222478833331'-1"R=10"R-135ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:05:59 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOEXTERIOR ELEVATIONSA20114 DECEMBER, 202020-18DBNDBNSCALE:1/8" = 1'-0"A201D1WEST ELEVATIONSCALE:1/8" = 1'-0"A201C1SOUTH ELEVATIONSCALE:1/4" = 1'-0"A201C3ENTRY ELEVATION2018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 3'-4"2'-6" 1'-11" 1'-6" 2'-0" 1'-6" 2'-0" 1'-6" 2'-0" 1'-6" 1'-6"2'-10"36" WIDE ADA TRANSACTION COUNTER, EAST SIDE ONLYSOLID SURFACE COUNTERTOPPLASTIC LAMINATE CABINETS, MELAMINE INTERIORREG. REG. REG.PROVIDE 2" HOLE WITH GROMET AT EACH REGISTER2'-6" 2'-0" 1'-6" 1'-6" 1'-6" 2'-0" 2'-6"SOLID SURFACE COUNTERTOPPLASTIC LAMINATE CABINETS, MELAMINE INTERIORPRINTERPROVIDE 2" HOLE WITH GROMET AT EACH REGISTER. FIELD VERIFY2'-10"15'-0"CLEAR3'-3"SOLID SURFACE COUNTERTOP WITH INTEGRAL BACKSPLASHPLASTIC LAMINATE CABINETS, MELAMINE INTERIORREFR.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:07:21 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOINTERIOR ELEVATIONSA25114 DECEMBER, 202020-18DBNDBNSCALE:1/4" = 1'-0"A251D5CASH WRAP COUNTER - EAST (WEST SIMILAR)SCALE:1/4" = 1'-0"A251CASH WRAP COUNTER - NORTHD4SCALE:1/4" = 1'-0"A251BREAKROOM COUNTERC52018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXISTB129'-0"T.O. PARAPET - HIGHEXISTING CMU WALLPREMANUFACTURED METAL PARAPET CAP. WRAP ROOF MEMBRANE UP AND OVER PARAPET BENEATH CAPEXISTING ROOF STRUCTUREFOUNDATION SYSTEM. SEE STRUCTURALSINGLE PLY ROOFING MEMBRANE OVER R-5 RIGID INSULATION** NOTE: WRAP ALL NEW METAL STUD FRAMING WITH DENSGLASS SHEATHING AND FLUID APPLIED AIR BARRIER U.N.O. **SEAL NEW ROOF MEMBRAND AND EXISTING ROOF SURFACES TOGETHER. FIELD VERIFY.FLASHING W/ 8" VERTICAL LEGSYNTHETIC STONE VENEEROPTIONAL: INFILL FOUNDATION VOID W/ CONCRETE.8"4"4"EIFS CORNICE100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXIST127'-0"T.O. PARAPET - LOWBALUMINUM STOREFRONT ENTRY SYSTEM, SEE DOOR/WINDOW TYPESSTRUCTURAL FRAMING CONNECTIONS. SEE STRUCTURAL DETAILS2" EIFS SYSTEM OVER AIR / VAPOR BARRIER / DENSGLASS SHEATHING / METAL STUDS.STANDING SEAM METAL ROOF OVER ICE & WATER SHIELD OVER WOO STRUCTURE.PREMANUFACTURED METAL PARAPET CAP. WRAP ROOF MEMBRANE UP AND OVER PARAPET BENEATH CAPEXISTING ROOF STRUCTUREEIFS SYSTEM OVER FRAMED WALL. SEE WALL TYPES.3/4" PLYWOOD BACKING FOR SIGNAGESINGLE PLY ROOFING MEMBRANE OVER DENSDECK SHEATHING** NOTE: WRAP ALL NEW METAL STUD FRAMING WITH DENSGLASS SHEATHING AND FLUID APPLIED AIR BARRIER U.N.O. **SEAL NEW ROOF MEMBRAND AND EXISTING ROOF SURFACES TOGETHER. FIELD VERIFY.ALUMINUM FASCIA & SOFFIT. MATCH STANDING SEAM COLORCONTINUOUS RAINGUTTER WITH DOWNSPOUTSPRE-FINISHED FLASHING W/ 8" VERTICAL LEG10'-0" 3'-2"5'-5"100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXISTBEXISTING ROOF STRUCTURE2X10 LEDGER. SEE STRUCTURAL3 1/8 X 15 GLB, SEALED5/8" PLYWOOD SHEATHING2X10 @ 24" O.C.EXISTING CMU10'-0"7'-2"1/4" COLUMN CAP W/ 10"X8"X1/4" BUCKETBASE PLATESPOT FOOTING & FOUNDATION. SEE FOUNDATION SCHEDULENEW PARAPET CAP12'-0"STANDING SEAM METAL ROOFING5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:10:16 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOWALL SECTIONSA30114 DECEMBER, 202020-18DBNDBNSCALE:3/8" = 1'-0"A301SECTION @ METAL PANELD4SCALE:3/8" = 1'-0"A301Section @ STOREFRONTD3SCALE:3/8" = 1'-0"A301SECTION @ SHED ROOFD12018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:11:43 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHO3-D VIEWSA30214 DECEMBER, 202020-18DBNDBNSCALE:A302D3PERSPECTIVE - SOUTH-WESTSCALE:A302D1PERSPECTIVE - SOUTH-EASTSCALE:A302C4AXINOMETRIC - SOUTH-WESTSCALE:A302SHED ROOF COLUMNB1SCALE:A30213D View 12018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 GENERAL NOTESA- THE CONTRACTOR IS TO VERIFY THE DIMENSIONS OF ALL OPENINGS PRIOR TO THE FABRICATION OF ALL DOORS AND FRAMES.B- DUE TO MULTIPLE USE, SOME OF THE DETAILS REFERRED TO ON THE DOOR SCHEDULE ARE REVERSED OR TURNED FROM THE DIRECTION SHOWN ON THE FLOOR PLANS. THE INTENT OF THE DETAILS IS TO BE FOLLOWED. CONSULT THE ARCHITECT WHEN QUESTIONS ARISE.C- ALL EXIT ACCESS DOORS AND EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE, OR EFFORT. USE OF MANUAL FLUSH BOLTS, EDGE BOLTS, TOP OR BOTTOM BOLTS, ETC., IS PROHIBITED.D- DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES WILL BE 5 SECONDS MINIMUM.E- FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE REQUIRED FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE 5 POUNDS. THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION.F- THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC DOORS, POWER ASSISTED DOORS, AND SLIDING DOORS SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHEN NARROW STILE AND RAIL DOORS ARE USED, A 10" MINIMUM, SMOOTH PANEL, EXTENDING THE FULL WIDTH OF THE DOOR, SHALL BE INSTALLED ON THE PUSH SIDE(S) OF THE DOOR WHICH ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. CAVITIES CREATED BY KICK PLATES SHALL BE CAPPED.G- ALL DOOR LOCKSETS SHALL BE ADA COMPLIANT LEVER TYPE.H- CAULK HEAD, JAMBS, AND SILLS OF ALL DOORS AND WINDOWS WITH SEALANT CONTINUOUSLY APPLIED TO BOTH SIDES OF THE FRAMES.J- COORDINATE KEYING TYPE AND SCHEDULE WITH OWNER.K- ALL DOOR CLOSURES TO BE SET IN ACCORDANCE WITH THE ADA REDUCED DOOR CLOSER4" MAXIMUM PROJECTION INTO CLEAR WIDTHWHERE VISION LIGHTS ARE PROVIDED, LIGHTS SHOULD EXTEND TO WITHIN 43" OF FINISHED FLOORDOOR HARDWARE TO BE LOCATED BETWEEN 34" AND 40" ABOVE FINISHED FLOORBOTTOM 10" OF DOOR SURFACE TO BE SMOOTH34" (NO PROJECTIONS PERMITTED)32" (MINIMUM CLEAR WIDTH)90 DEGREESNOTE: HARDWARE TO BE OPERATED WITH ONE HAND, WITHOUT TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THRESHOLDS ARE LIMITED TO 1/2" MAXIMUM HEIGHT. INTERIOR DOORS, OTHER THAN FIRE DOORS, SHOULD BE ABLE TO BE OPERATED WITH 5 POUNDS OF FORCE. EXTERIOR DOOR AND FIRE DOORS ARE REGULATED BY THE AUTHORITY HAVING JURISDICTION. REFER TO ANSI STANDARD A117.1 FOR APPROACH REQUIREMENTS. 1/4" MAX1/4" TO 1/2" MAX12NOTE: CHANGES IN LEVEL GREATER THAN 1/2" MUST BE RAMPED WITH 1:12 MAXIMUM SLOPE. CHANGES IN LEVEL IN CLEAR FLOOR SPACE, MANEUVERING CLEARANCES, WHEELCHAIR TURNING SPACE AND ACCESS AISLES ARE PROHIBITED. FINISHED FLOOR7'-2"3'-4"A3FE10'-0"10'-0"427'-4"3'-4"B56MASONRY346'-4"7'-2"76'-4"7'-2"CD7'-2"3'-4"A311T1T1T1T1T1T37'-4" FIELD VERIFY10'-0"2'-4"VFY R.O. W/ DORMA7'-8"4'-6"ROUGH OPENING12'-0"4'-4"ROUGH OPENING12'-0"4'-6"1T1T1T1T1T11111111111GLAZING SCHEDULEEXTERIOR: 1" INSULATED LOW-E GLASS - PPG SOLARBAN 60 XL OR EQUIVELANTINTERIOR: 3/8" CLEAR GLAZINGGLAZING TO BE TEMPERED1TSHEET NOTES1. PRE-FINISHED ALUMINUM STOREFRONT ENTRY SYSTEM WITH THERMAL BREAKS. DOORS ARE TO BE AUTOMATIC BI-PARTING STOREFRONT MANUFACTURED BY DORMAKABA , MODEL TO BE DETERMINED. CLEAR ANODIZED FINISH2. COILING OVERHEAD DOOR. MANUFACTURED BY CORNELL , INSULATED, MIN. 24 GA. STEEL. MODEL TO BE DETERMINED3. PAINTED HOLLOW METAL DOOR FRAME 4. PAINTED HOLLOW METAL DOOR 5. PAINTED HOLLOW METAL DOOR FRAME WITH GALVALUME TREATMENT6. PAINTED HOLLOW METAL DOOR WITH GALVALUME TREATMENT.7. DOUBLE SWINGING STOREROOM DOOR. ELIASON PE-500 TRAFFIC DOOR OR EQUAL. BEIGE COLOR OR SIMILAR.8. CHAIN LINK EGRESS GATE WITH EGRESS HARDWARE INSTALLED.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:12:50 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHODOOR TYPES & DETAILSA60114 DECEMBER, 202020-18DBNDBNSCALE:A2A601DOOR TYPES1/4" = 1'=0"SCALE:1/4" = 1'-0"A601ACCESSIBLE DOORC5SCALE:1/4" = 1'-0"A601FLOOR TRANSITIONSD5DOOR HARDWARE GROUP 1 - ALUM. ENTRY, DOUBLE SWING, COILINGHARDWARE BY MFR. DOOR HARDWARE GROUP 2 - SINGLE EXTERIOR EGRESS DOOR3 BB HINGES1 ALARMED PANIC HARDWARE - DETEX OR EQUAL1 CLOSER W/ OVERHEAD STOP1 SET SEALS1 THRESHOLD 1 SWEEPDOOR HARDWARE GROUP 3 - DRESSING ROOMS / OFFICES3 BB HINGES1 ADA OFFICE LOCKSET1 SET SOUND SEALS1 WALL STOPDOOR HARDWARE GROUP 4 - GUN ROOM3 BB HINGES1 ADA COMPLIANT STOREROOM LOCKSET1 DEADBOLT WITH THUMBTURN1 CLOSER W/ OVERHEAD STOP2 KICK PLATE, STAINLESS1 SET SILENCERSDOOR HARDWARE GROUP 5 - BREAKROOM3 BB HINGES1 ADA COMPLIANT PASSAGE LOCKSET1 CLOSER 1 SET SOUND SEALS1 WALL STOP2 KICK PLATE, STAINLESSDOOR HARDWARE GROUP 6 - DOUBLE DOOR - JANITOR6 BB HINGES1 ADA COMPLIANT STOREROOM LOCKSET1 MANUAL FLUSH BOLT, TOP1 SET SEALS2 WALL STOP4 KICK PLATE, STAINLESS2 SET SILENCERSDOOR HARDWARE GROUP 7 - DOUBLE DOOR - EGRESS6 BB HINGES2 ALARMED PANIC HARDWARE - DETEX OR EQUALKEYED ASTRAGAL2 CLOSER W/ OVERHEAD STOP1 WALL STOP2 SET SILENCERSDOOR HARDWARE GROUP 7 - DOUBLE DOOR - EGRESS6 BB HINGES2 ALARMED PANIC HARDWARE - DETEX OR EQUALKEYED ASTRAGAL2 CLOSER W/ OVERHEAD STOP1 WALL STOP2 SET SILENCERSDOOR HARDWARE GROUP 7 - DOUBLE DOOR - EGRESS6 BB HINGES2 ALARMED PANIC HARDWARE - DETEX OR EQUALKEYED ASTRAGAL2 CLOSER W/ OVERHEAD STOP1 WALL STOP2 SET SILENCERSDOOR HARDWARE GROUP 8 - YARD EGRESS GATE2 BB HINGES1 ALARMED PANIC HARDWARE - DETEX EXTERIOR RATED OR EQUAL2 CLOSER W/ OVERHEAD STOPDOOR SCHEDULEMARK TYPEDOOR SIZE MATERIALHARDWARERATINGCOMMENTSWIDTH HEIGHT THICKDOORFRAMELEVEL 1 FLOOR100A G 3'-0" 7'-8" 2" ALUM / GLASS ALUM 1 - DORMA 12' X 10' BI-PARTING DOOR PACKAGE100B G 3'-0" 7'-8" 2" ALUM / GLASS ALUM 1 - DORMA 12' X 10' BI-PARTING DOOR PACKAGE100C G 3'-0" 8'-0" 2" ALUM / GLASS ALUM 1 - DORMA 12' X 10' BI-PARTING DOOR PACKAGE100D G 3'-0" 8'-0" 2" ALUM / GLASS ALUM 1 - DORMA 12' X 10' BI-PARTING DOOR PACKAGE101D B 3'-0" 7'-0" 2" STEEL STEEL 2 WEST EMERGENCY EGRESS102 A 3'-0" 7'-0" 2" STEEL STEEL 3 - DRESSING103 A 3'-0" 7'-0" 2" STEEL STEEL 3 - ADA DRESSING105A D 6'-0" 7'-0" 2" STEEL STEEL 4 - ELIASON PE-500 TRAFFIC DOOR105B D 6'-0" 7'-0" 2" STEEL STEEL 4 - ELIASON PE-500 TRAFFIC DOOR106 A 3'-0" 7'-0" 2" STEEL STEEL 5 - BREAK106A C 6'-0" 7'-0" 2" STEEL STEEL 6 - JANITOR107 C 6'-0" 7'-0" 2" STEEL STEEL 7 - HALL108 A 3'-0" 7'-0" 2" STEEL STEEL 3 - OFFICE109 A 3'-0" 7'-0" 2" STEEL STEEL 3 - OFFICE110 A 3'-0" 7'-0" 2" STEEL STEEL 4 - GUN112 A 3'-0" 7'-0" 2" STEEL STEEL 4 - RISER ROOM113 A 3'-0" 7'-0" 2" STEEL STEEL 4 - I.T.114A E 10'-0" 10'-0" 2" STEEL STEEL 3 - COILING DOOR114B C 6'-0" 7'-0" 2" STEEL STEEL 7 - YARD DOUBLE DOORS115 F 3'-0" 7'-0" 2" CHAIN LINK CHAIN LINK 8 YARD EGRESS GATE(4) 12'-0" X 10'-0" DORMA BI-PARTING DOOR PACKAGE. VERIFY REQUIRED DIMNESIONS WITH DORMADOOR HARDWARE GROUPS12'-0"12'-0"12'-0"12'-0"10'-0"10'-0"10'-0"10'-0"12018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 1010332211FFBB445566CCDDJJHHGGEE77889930'-4"42'-10"35'-0"43'-10"30'-10"32'-2"46'-0"28'-5" 40'-6" 40'-6" 43'-0" 41'-3" 40'-10" 39'-3" 39'-3" 38'-2"352'-0"108'-10".144'-0"RAMPRAMP26'-0" 60'-0"266'-0"10'-0" 9'-0" 22'-0" 9'-0" 10'-0"104A3AD201B1RISER (EX)1121ELEC (EX)11122616106691111161111222X102D162'-9"2521552212222222222'-0" 6'-4" 1'-10"552"1167863123167''-3" H6'-5"56'-0"10'-0" H10'-0"15'-4"101011111111111111111111A201C34'-0"SHEET NOTES1. DEMOLISH EXISTING DOOR / WINDOW SYSTEM2. DEMOLISH PORTION OF WALL AS SHOWN. COORDINATE EXTENT WITH NEW CONSTRUCTION3. DEMOLISH EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPING.4. DEMOLISH ALL CEILING SYSTEMS, DUCTWORK, CONDUIT, ETC. WITHIN THE CAL RANCH TENANT AREA5. DEMOLISH EXISTING BOLLARDS6. DEMOLISH EXISTING MILLWORK7. EXISTING WALLS & DOORS TO REMAIN8. EXISTING PLUMBING FIXTURES TO REMAIN9. EXISTING ELECTRICAL EQUIPMENT. SEE ELECTRICAL DRAWINGS FOR DEMOLITION & RECONSTRUCTION REQUIREMENTS10. DEMOLISH EXISTING CMU WALL FOR NEW DOORWAY.11. DEMOLISH EXISTING CEILING SYSTEM.12. EXISTING FIRE RISER EQUIPMENT. SEE PLUMBING DRAWINGS FOR DEMOLITION & RECONSTRUCTION REQUIREMENTS13. DEMOLISH EXISTING ELECTRICAL CONDUIT, WIRING, SWITCHES, EXIT SIGNS, ETC.GENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THEARCHITECT.B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES.C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS.PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS.D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL E. SEE SHEET A151 FOR REFLECTED CEILING PLAN INFORMATION..F. SEE A601 FOR DOOR INFORMATION.G. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHERARCHITECTURAL GENERAL INFORMATION.H. DO NOT SCALE DRAWINGS.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 7:58:54 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHODEMOLITION FLOOR PLANAD10114 DECEMBER, 202020-18DBNDBNSCALE:1/16" = 1'-0"AD101D1DEMOLITION FLOOR PLANN12018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 1010332211FFBB445566CCDDJJHHGGEE778899261'-8"30'-4" 42'-10" 35'-0" 43'-10" 30'-10" 32'-2" 46'-0"28'-5" 40'-6" 40'-6" 43'-0" 41'-3" 40'-10" 39'-3" 39'-3" 38'-2"352'-0"EXISTINGHARBORFREIGHTSUITE 4RAMPELEC (EX)111RISER (EX)1121121AAJAN. (EX.)HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105VESTIBULE100AADADRESSING103DRESSING102SALESFLOOR - A101OUTDOORYARD115I.T.113SALESFLOOR - C114SALESFLOOR - B104CARTS100B4111111111111222211152523312222222222222222211112SHEET NOTES1. REMOVE ALL FLOORING, GRIND CONCRETE SMOOTH AND SEAL.2. ALL GYP. BOARD WALL FINISHES TO BE SMOOTH "CAL RANCH TAN" IF262-17.3. PROVIDE ADA COMPLIANT TRANSITION 4. NEW WALK-OFF CARPET 5. NEW CARPET TILE WITH ENHANCED BACKING.GENERAL NOTESA. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THE ARCHITECT.B. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS. PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS. C. ALL COLORS SELECTIONS AND FINISH MATERIALS AND STYLES SHALL BE COORDINATED WITH OWNER. D. MILLWORK SHOWN FOR CLARITY. PROVIDE FLOORING UNDER EQUIPMENT, MILLWORK AND COUNTERTOPS. E. SEE INTERIOR ELEVATIONS ON A251 FOR FINISHES OF MILLWORK BASES, AND COUNTERTOPS. F. PAINTED DOOR TRIM COLOR TO BE SELECTED BY OWNER. G. FINAL FINISH SELECTION TO BE COORDINATED WITH ARCHITECT, OWNER AND INTERIOR DESIGNER.H. CONTRACTOR TO VERIFY TRANSITION STRIP DIMENSIONS WITH MATERIAL THICKNESSES.J. RUN FLOORING UNDER MILLWORK.5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:05:03 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOINTERIOR FINISHESAI10114 DECEMBER, 202020-18DBNDBNSCALE:1/16" = 1'-0"AI101E1NEW FLOOR PLAN - FINISHESN2018/1/162018/9/292020/3/172020/6/22020-6-32020/8/312020-12-14 10321B456C789F1,W1 F1,W1B5S101.B3S101.B2S101.W2,F2 W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2W2,F2A201C3DRILL & EPOXY ALL NEW HORIZONTAL FOOTING AND WALL STEEL 4" MIN. INTO EXISTING CONCRETEDRILL & EPOXY ALL NEW HORIZONTAL FOOTING AND WALL STEEL 4" MIN. INTO EXISTING CONCRETESHEET NOTES1. ATTACH DIAGONAL TO 6" STUD SEGMENT ATTACHED TO MASONRY WALL W/ (2) P.A.F.2. PRE-ENGINEERED ROOF TRUSS3. ALL STUD FRAMING TO HAVE 1 5/8" FLANGES X 18 GA. SPACED AT 16" O.C. U.N.O.4. ATTACH DECK TO BLOCKING W/ (1) #10 SCREW EACH FLUTE5. 6" STUD BLOCKING6. DRILL & EPOXY ALL NEW HORIZONTAL FOOTING AND WALL STEEL 4" MIN. INTO EXISTING CONCRETE7. ATTACH TRACK TO CONCRETE W/ HILTI X-U .157 DIA X 1 1/4 POWDER ACTUATED FASTENERS (P.A.F.) AT 16" O.C. USE SPECIFIED P.A.F. FOR ALL CONNECTIONS TO CONCRETE AND MASONRY.8. ATTACH TRACK TO TOP OF MASONRY W/ SHOT P.A.F. AT 12????????????" O.C.9. ALL STUD TO STUD CONNECTIONS TO BE MADE W/ (2) #10 SCREWS MIN.10. 10321B456789B5S101.B3S101.5/8" PLYWOOD OVER 2X10 @ 24" O.C., TYPICALB2S101.3 1/8X15 GLB (LOW), ENDS ONLY2X10 (HIGH)3 1/8X15 GLB (LOW)ENDS ONLY2X10 (HIGH)3 1/8 X 15 GLB2X10 LEDGER, TYPICAL3 1/8X15 GLB (LOW) ENDS ONLY2X10 (HIGH)3 1/4 X 15 GLB2X10 LEDGER, TYPICAL6X6X1/4" STEEL COLUMN, TYPICAL2x10 @ 24" O.C.2x10 @ 24" O.C.ROOF TRUSSES @ 24" O.C.6X6X1/4" STEEL COLUMN, TYPICAL, W/ 1/4" PLATE STEEL BUCKET2X10 LEDGER, TYPICAL100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXISTB129'-0"T.O. PARAPET - HIGH3 5/8 X 20 GA. W/ (3) #10 SCREWS INTO FRAMING AND (2) #12 SCREW INTO TRUSS6" METAL STUDS AT 12" O.C.CUT OFF DECK AND MAKE SURE DECK IS ATTACHED TO STEEL10" 19'-0"3 5/8 X 20 GA. W/ (2) #10 SCREWS INTO FRAMING AND (1) #12 SCREW INTO THE ANGLE5/8" PLYWOOD SHEATHING OVER METAL ROOF TRUSSES @ 24" O.C.3 5/8 X 20 GA. W/ (3) #10 SCREWS INTO FRAMING AND (2) #12 SCREWS INTO DECK100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXISTB129'-0"T.O. PARAPET - HIGHEXISTING CMU WALL6" METAL STUD FRAMING EXISTING ROOF STRUCTURE8" CONCRETE WALL. REINFORCE W/ #4 VERTICAL DOWELS AT 18" O.C. AND (2) #4 HORIZ. TOP AND BOTTOMSPACE FULL HEIGHT STUDS AT 8" O.C.10" X 20" FOOTING, MINIMUM 36" FROST DEPTH. (2) #4 LENGTHWISE8PARAPET CAP BLOCKING4'-10"ATTACH TRACK TO TOP OF MASONRY W/ 1/2" DIA. X 6" SIMPSON TITEN HD ANCHORS AT 16" O.C. PROVIDE CUT WASHERSALL STUD TO STUD CONNECTIONS TO BE MADE W/ (2) #10 SCREWS MIN.ATTACH TRACK TO CONCRETE W/ HILTI X-U .157 DIA X 1 1/4 POWDER ACTUATED FASTENERS (P.A.F.) AT 16" O.C. USE SPECIFIED P.A.F. FOR ALL CONNECTIONS TO CONCRETE AND MASONRY.6" TRACK SHOT TO CMU W/ P.A.F. AT 16" O.C.BRACE STUDS AT THIRD POINTS W/ SAME SIZE STUDS100'-0"FINISHED FLOOR123'-4"T.O. PARAPET - EXISTBEXISTING ROOF STRUCTURE2X10 LEDGER ANCHORED TO CMU W/ STAINLESS STEEL 3/4" X 6" SIMPSON TITEN HD ANCHORS AT 24" O.C. AND SIMPSON LR4210Z HANGER EACH JOIST. ANCHOR TO SOLID GROUTED CELLS ONLY. GROUT CELLS AS NEEDED.3 1/8 X 15 GLB5/8" PLYWOOD SHEATHING2X10 @ 24" O.C.EXISTING CMU10'-0"7'-0"3/8" COLUMN CAP W/ 10"X8"X1/4" BUCKET. ATTACH W (4) 3/4" DIA. A307 BOLTS5/8" X 10" X 10" BASE PLATE W/ (4) 3/4" DIA. X 12" J BOLTS SET ON 1 1/2" NON-SHRINK GROUTSPOT FOOTING & FOUNDATION. SEE FOUNDATION SCHEDULEHSS 4X4X41/4"SIMPSON H2.5A EACH RAFTER5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OF DALLAS NELSON ARCHITECTURE, INC. AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2020 D.N.A., INC.DALLAS NELSON ARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM 1912 CONCORD PLACESARATOGA SPRINGS, UT 8404512/14/2020 8:01:01 AMC:\Users\dallasn\Dropbox\Projects\2020\20-18 - Cal Ranch TBO - Rexburg\Working\Revit\20-18 - Rexburg Cal Ranch - 2020-12-12.rvtCAL RANCH REXBURG TBO530 N. 2ND EAST - SOUTH SUITEREXBURG, IDAHOSTRUCTURAL PLANS & DETAILSS101.14 DECEMBER, 202020-18DBNDBNSCALE:1/16" = 1'-0"S101.D1STRUCTURAL FOUNDATION PLANNSCALE:1/16" = 1'-0"S101.STRUCTURAL ROOF PLANB1NSCALE:1/4" = 1'-0"S101.STRUCTURAL SECTION @ STOREFRONTB5SCALE:1/4" = 1'-0"S101.STRUCTURAL SECTION @ PILASTERB3F1: 10" X 20" CONTINUOUS FOOTING W/ (2) #4 LENGTHWISEF2: 30" X 30" X 10" SPOT FOOTING W1: 10" CONCRETE WALL. REINFORCE W/ #4 VERTICAL DOWELS AT 18" O.C. AND (2) #4 HORIZ. TOP AND BOTTOMW2 14" X 14" CONCRETE PIERSCALE:1/4" = 1'-0"S101.STRUCTURAL SECTION @ SHED ROOFB2FOOTING / FOUNDATION SCHEDULE4X4X1/4"4X4X1/4" DESIGN CONTACTSSHEET INDEXSITE CONDITIONS’“” ’DUCTWORK SEISMIC SUPPORT NOTES:COMMISSIONING NOTES:SUBMITTALS:PROJECT MECHANICAL NOTES:5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM0.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL NOTESAND LEGENDS 10321FB456CDJHGE778899MECHANICAL DEMO PLANNMECHANICAL KEYED NOTES:HARBORFREIGHTSUITE 4104ELEC (EX)111RISER (EX)112HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105CASH WRAP102VESTIBULE100DRESSING104DRESSING103SALESFLOOR101SALESFLOOR101OUTDOORYARD114I.T.1135ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM1.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL DEMO PLAN 10321FB456CDJHGE778899MECHANICAL KEYED NOTES:MAIN FLOOR MECHANICAL PLANNHARBORFREIGHTSUITE 4104ELEC (EX)111RISER (EX)112HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105CASH WRAP102VESTIBULE100DRESSING104DRESSING103SALESFLOOR101SALESFLOOR101OUTDOORYARD114I.T.1135ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM1.27 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MM MAIN FLOOR MECHANICAL PLAN TYPICAL ROOF CURB DETAILTYPICAL CEILING MOUNTED EXHAUST FANCEILING EXHAUST FAN DETAILINSULATED ROUND TAKE-OFFBRANCH DUCT TAKE-OFFDIFFUSER CONNECTION DETAILDUCT LINER DETAILDUCT CONSTRUCTION DETAILTYPICAL RTU INSTALLATION DETAILRTU CONTROL SEQUENCE5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM5.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL DETAILS V = R P + R AOUTSIDE AIR BALANCING SCHEDULEELECTRIC WALL HEATER SCHEDULEEXHAUST FAN SCHEDULEPACKAGED ROOFTOP UNITHEAT PUMP UNIT SCHEDULE - OUTDOOR UNITFAN COIL SCHEDULE - INDOOR UNIT5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM6.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL SCHEDULES 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM7.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL SPECIFICATIONS 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM7.27 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL SPECIFICATIONS 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOM7.37 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMMECHANICAL SPECIFICATIONS SUBMITTAL NOTES:PIPING SEISMIC SUPPORT NOTES:DESIGN CONTACTSPLUMBING SYMBOLSSHEET INDEXPROJECT PLUMBING NOTES:PROJECT PLUMBING NOTES:5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP0.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING NOTESAND LEGENDS 10321FB456CDJHGE778899PLUMBING DEMO PLANNPLUMBING KEYED NOTES:HARBORFREIGHTSUITE 4104ELEC (EX)111RISER (EX)112HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105CASH WRAP102VESTIBULE100DRESSING104DRESSING103SALESFLOOR101SALESFLOOR101OUTDOORYARD114I.T.1135ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP1.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING DEMO PLAN 10321FB456CDJHGE778899PLUMBING KEYED NOTES:MAIN FLOOR PLUMBING PLANNHARBORFREIGHTSUITE 4104ELEC (EX)111RISER (EX)112HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105CASH WRAP102VESTIBULE100DRESSING104DRESSING103SALESFLOOR101SALESFLOOR101OUTDOORYARD114I.T.1135ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP1.27 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MM MAIN FLOOR PLUMBING PLAN ELEC (EX)111HALL107OFFICE108OFFICE109BREAK106ENLARGED PLUMBING PLANNPLUMBING KEYED NOTES:5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP4.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMENLARGED PLUMBING PLAN TYPICAL VENT THROUGH FLAT ROOF DETAILTYPICAL FLOOR CLEANOUT DETAILTYPICAL WALL CLEANOUT DETAILTYPICAL SURFACE CLEANOUT DETAILTYPICAL 2LB GAS CONNECTION DETAILROOF MOUNTED GAS PIPING DETAILGAS METER INSTALLATIONPIPE WITH CLEVIS HANGERS DETAILFLOOR DRAIN WITH TRAP GUARD DRAIN SEAL (CONCRETE FLOOR)5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP5.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING DETAILS WATER PRV STATION WITH BACKFLOW PREVENTER DETAILTYPICAL DIRECT POWER VENT GAS WATER HEATER DETAILRECIRCULATION PUMP WITH WATER HEATER DETAILWATER TEMPERING DETAILSMECHANICAL PIPING - MINIMUM INSULATION THICKNESSTEMPERATURESERVICERANGE (°F)NOTES> 120 PSI STEAM> 350251 - 350201 - 250141 - 200105 - 1401, 2, 3, 5, 6HOT WATERHOT WATER16 - 120 PSI STEAM0 - 15 PSI STEAMPIPE SIZE (IN.)< 12 TO 3-1/24 TO 7-1/28 & LARGER2.51.51.51.51.534332243322COOLING SYSTEMS40 - 6033221.5222COOLING COIL CONDENSATE32 - 65.5.5.5.51, 2, 3, 5, 61, 2, 3, 5, 61, 3, 5, 61, 3, 5, 61, 3, 4, 5, 6TEMPERATURESERVICERANGE (°F)NOTESDOMESTIC COLD WATER45 - 9090+90+32+1, 2, 3ROOF DRAIN PIPINGDOMESTIC HOT WATERSERVICE HOT WATERPIPE SIZE (IN.)< 12 TO 3-1/24 TO 7-1/28 & LARGER11111, 2, 3, 41, 2, 3, 41, 2, 3, 51, 5, 611.51.51.511.51.51.511111 TO 1-1/232.51.5.5111.51.51.51 TO 1-1/211PIPING INSULATION DETAILPLUMBING PIPING - MINIMUM INSULATION THICKNESS5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP5.27 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING DETAILS BUILDING WATER PIPING CALCULATIONSWBUILDING WATER METERWASTE AND VENT PIPING SCHEMATICSTYPICAL WATER CLOSETTYPICAL FLOOR DRAINTYPICAL LAVATORYWATER PIPING SCHEMATICSTYPICAL HOSE BIBTYPICAL LAVATORY / SINKTYPICAL MOP SINKTYPICAL MOP SINKTYPICAL DRINKING FOUNTAINTYPICAL FRIDGE CONNECTIONTYPICAL SINKTYPICAL DRINKING FOUNTAINTYPICAL WATER HEATERTYPICAL WATER CLOSET - VALVEPLUMBING FIXTURE SCHEDULENOTES:1. VERIFY ALL MANUFACTURERS, FINISHES, AND OPTIONS WITH OWNER BEFORE ORDERING ANY PLUMBING FIXTURES.2. MINIMUM UNDERGROUND SANITARY SEWER PIPING SIZE SHALL BE 2 INCHES.CAL RANCH GAS PIPING CALCULATIONS5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP6.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING SCHEDULESAND SCHEMATICS 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP7.17 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING SPECIFICATIONS 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.DALLAS NELSONARCHITECTURE, INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045REXBURG CAL RANCH TBO530 N. 2ND EASTREXBURG, IDAHOP7.27 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMPLUMBING SPECIFICATIONS 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMDESIGN CONTACTSCOMMISSIONING NOTES:’ ELECTRICAL GENERAL NOTES:ABBREVIATIONS INDEXɸɸɸELECTRICAL SYMBOLSSHEET INDEX 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMSITE ELECTRICAL PLANNELECTRICAL KEYED NOTES: 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMM1010332211FFBB445566CCDDJJHHGGEE778899LIGHTING PLANNHARBORFREIGHTSUITE 4104ELEC (EX)111RISER (EX)112HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105CASH WRAP102VESTIBULE100DRESSING104DRESSING103SALESFLOOR101SALESFLOOR101OUTDOORYARD114I.T.113ELECTRICAL KEYED NOTES: 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMM1010332211FFBB445566CCDDJJHHGGEE778899POWER PLANNHARBORFREIGHTSUITE 4104ELEC (EX)111RISER (EX)112HALL107GUN ROOM110OFFICE108OFFICE109BREAK106STORAGE105CASH WRAP102VESTIBULE100DRESSING104DRESSING103SALESFLOOR101SALESFLOOR101OUTDOORYARD114I.T.113ELECTRICAL KEYED NOTES:ENLARGED FIRE RISER POWER PLAN 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMPANEL SCHEDULE "H"VOLTAGE:480Y/ 277 VOLTSBUS RATING (AMPS):100REMARKS:MOUNTING:SURFACEPHASE:3MAIN LUGS ONLYENCLOSURE:NEMA 1WIRE:4MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLECIRCUIT BREAKERCIRCUIT NAMEFEEDERCKT. LOADLOAD/PHASE (VA)CKT. LOADFEEDERCIRCUIT NAMECIRCUIT BREAKERNo.AMPSPOLEMOD.CWIREGRDDEMANDFACTORWATTSØAØBØCWATTSDEMANDFACTORGRDWIRECMOD.POLEAMPSNo.1201-RISER ROOM LIGHTING¾"#12#121.25507657151.25#12#12¾"EXISTING WALL PACK-12023201-EXISTING PARKING LIGHT¾"#10#101.252,0643,4401,3761.25#10#10¾"EXISTING PARKING LIGHT-12045201-EXISTING PARKING LIGHT¾"#10#101.252,0642,2321681.25#12#12¾"FAÇADE SCONCES-12067201-LCP1¾"#12#121.002002001.25SPACE-89453-TRANSFORMER X1¾"#8#101.001,6801,6801.25SPACE-1011-----#8-1.005005001.00SPACE-1213-----#8-1.002002001.00SPACE-1415-SPACE1.0001.00SPACE-1617-SPACE1.0001.00SPACE-1819-SPACE1.0001.00SPACE-2021-SPACE1.0001.00SPACE-2223-SPACE1.0001.00SPACE-2425SPACE1.0001.00SPACE-2627-SPACE1.0001.00SPACE-2829-SPACE1.0001.00SPACE-3031-SPACE1.0001.00SPACE-3233-SPACE1.0001.00SPACE-3435-SPACE1.0001.00SPACE-3637-SPACE1.0001.00SPARE-1203839-SPACE1.0001.00SPARE-1204041-SPACE1.0001.00SPARE-12042NOTES :1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØAØBØCTOTALSINSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.1,1655,1202,7329,017CONNECTED LOAD (VA)2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL11CONNECTED LOAD (A)ELECTRICAL CODE.1918605581,609DEMAND FACTOR ADJUSTMENTS (VA)3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT1,3565,9803,29010,626TOTAL LOAD (VA)LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL52212TOTAL LOAD (A)READ: "DANGER: POTENTIAL ARC FLASH HAZARD"22MAXIMUM LOAD (A)4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL13%56%31%PHASE BALANCEEFFICIENCY CERTIFICATES PER IECC R401.35.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELSSTATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST.PANEL SCHEDULE "HP"VOLTAGE:208Y/ 120 VOLTSBUS RATING (AMPS):100REMARKS:MOUNTING:SURFACEPHASE:3MAIN CIRCUIT BREAKER:50ENCLOSURE:NEMA 1WIRE:4MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLECIRCUIT BREAKERCIRCUIT NAMEFEEDERCKT. LOADLOAD/PHASE (VA)CKT. LOADFEEDERCIRCUIT NAMECIRCUIT BREAKERNo.AMPSPOLEMOD.CWIREGRDDEMANDFACTORWATTSØAØBØCWATTSDEMANDFACTORGRDWIRECMOD.POLEAMPSNo.1201-CONVENIENT RECEPTACLE¾"#12#121.001801,6801,5001.00#12#12¾"EWH-12023-SPACE1.005005001.00#12#12¾"FIRE ALARM PANELRED12045-SPACE1.002002001.00#12#12¾"SPRINKLER BELLRED12067-SPACE1.0001.00SPACE89-SPACE1.0001.00SPACE-1011-SPACE1.0001.00SPACE-1213-SPACE1.0001.00SPACE-1415-SPACE1.0001.00SPACE-1617-SPACE1.0001.00SPARE-1201819-SPACE1.0001.00SPARE-12020NOTES :1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØAØBØCTOTALSINSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.1,6805002002,380CONNECTED LOAD (VA)2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL7CONNECTED LOAD (A)ELECTRICAL CODE.0000DEMAND FACTOR ADJUSTMENTS (VA)3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT1,6805002002,380TOTAL LOAD (VA)LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL1442TOTAL LOAD (A)READ: "DANGER: POTENTIAL ARC FLASH HAZARD"14MAXIMUM LOAD (A)4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL71%21%8%PHASE BALANCEEFFICIENCY CERTIFICATES PER IECC R401.35.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELSSTATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST.LIGHT FIXTURE SCHEDULEFIXTURENUMBERFIXTUREMANUFACTURERFIXTURECATALOG #LAMPSFIXTUREDESCRIPTIONREMARKSTYPEQTY.VOLTSWATTSMOUNTINGF1LITHONIA OR APPROVEDEQUALIBG-24000LM-SEF-AFL-GND-277-GZ10-40K-80CRI-DWHLED 24000LM4000 KELVIN-277144SURFACELED 2X2 HIGH BAY2' 6 BARF1ELITHONIA OR APPROVEDEQUALIBG-24000LM-SEF-AFL-GND-277-GZ10-40K-80CRI-DWH-IE30WCPHELED 24000LM4000 KELVIN-277144SURFACELED 2X2 HIGH BAY WITH BATTERY PACK2' 6 BARF2METALUXLITHONIADAY-BRITELSICOLUMBIAORACLE24GR-LD5-48-F1-UNV-L835-CD1-U2GTL-4-48L-EZ1-LP8352-T-G-54L-835-4-FS-02F-UNV-DIMGA24-LED-HO-WW-UE-P12.125LJT24-35MLG-FSA12125-EDU24-OT-LED-5000L-DIM10-MVOLT-35K-85-A12LED3500 KELVIN4800 LUMENS80 CRI-27757LAY-INGRID2X4 LED LAY-IN PRISMATIC FIXTUREF2EMETALUXLITHONIADAY-BRITELSICOLUMBIAORACLE24GR-LD5-48-F1-UNV-L835-EL14W-CD1-U2GTL-4-48L-EZ1-LP835-EL14L2-T-G-54L-835-4-FS-02F-UNV-DIM-EMLEDGA24-LED-HO-WW-UE-P12.125-EMLJT24-35MLG-FSA12125-EDU-ELL1424-OT-LED-5000L-DIM10-MVOLT-35K-85-A12-O-EMG-LEDLED3500 KELVIN4800 LUMENS80 CRI-27757LAY-INGRID2X4 LED LAY-IN PRISMATIC FIXTURE WITH EMERGENCYBATTERY PACKF3HALO COMMERCIALLITHONIALIGHTOLIERATLANTICPRESCOLITEMAXILUMEPD610ED015/PDM6A835/61VCLDN6 35/15 LO6AR LSS MVOLT EZ1P6RD15NZ10UVB W/P6RD835VB W/P6RDCCLED6-DLM15-35K-U-6LED10-SSLF6SL-6LFSL15L35KHH6-LED-1500L-DIM10-MVOLT-MD-35K-90/HH6-6501-CL-WHLED3500 KELVIN1500 LUMENS80 CRI-27721RECESSEDLED DOWNLIGHT WITH ALZAK TRIMF3EHALO COMMERCIALLITHONIALIGHTOLIERATLANTICPRESCOLITEMAXILUMEPD610ED015IEM/PDM6A835/61VCEMLDN6 35/15 LO6AR LSS MVOLT EZ1 ELP6RD15NZ10UVBEM W/P6RD835VB W/P6RDCCLED6-DLM15-35K-U-ILEM-6LED10-SSLF6SLEM-6LFSL15L35KEMHH6-LED-1500L-DIM10-MVOLT-MD-35K-90-EMG-LED/HH6-6501-CL-WHLED3500 KELVIN1500 LUMENS80 CRI-27721RECESSEDLED DOWNLIGHT WITH ALZAK TRIM AND EMERGENCYBATTERY PACKF4LITHONIA OR APPROVEDEQUALTFX2-LED-40K-MVOLT-YK-DDBXDLED 13200LM4000 KELVIN-27794WALLFLOOD LIGHTF5METALUXLITHONIADAY-BRITELSICOLUMBIAORACLE4SNLED-LD4-44SL-LW-UNV-L835-CD1-UZL1N-L48-5000LM-FST-MVOLT-35K-80CRI-WHFSS455L835-UNV-DIMSDL-4-LED-HO-WW-UELCL4-35ML-EDU4-OC1-LED-4000L-DIM10-MVOLT-35K-80LED3500 KELVIN4000 LUMENS80 CRI-27753SURFACE48" LED STRIPF5EMETALUXLITHONIADAY-BRITELSICOLUMBIAORACLE4SNLED-LD4-44SL-LW-UNV-EL14W-L835-CD1-UZL1N-L48-5000LM-FST-MVOLT-35K-80CRI-E7W-WHFSS455L835-UNV-DIM-EMLEDSDL-4-LED-HO-WW-UE-EMLCL4-35ML-EDU-ELL144-OC1-LED-4000L-DIM10-MVOLT-35K-80-O-EMG-LEDLED3500 KELVIN4000LUMENS80 CRI-27753SURFACE48" LED STRIP WITH EMERGENCY BATTERY PACKF6METALUXLITHONIADAY-BRITELSICOLUMBIAORACLE8TSNLED-LD4-95SL-LW-UNV-L835-CD2-UZL1N-L96-10000LM-FST-MVOLT-35K-80CRI-WHFSS8100L835-UNV-DIMSDL8-LED-HO-WW-UELCL8-35ML-EU8-OC1-LED-6000L-DIM10-MVOLT-35K-80LED3500 KELVIN9500 LUMENS80 CRI-277106SURFACE96" LED STRIPF7BARN LIGHT OR APPROVEDEQUALBLE-G-ASFC12-CBA-G22-CBA-LED27-3500KLED3500 KELVIN-27727WALLGOOSENECKFINISH TO BE SELECTED BY ARCHITECTF8LITHONIA OR APPROVEDEQUALIBG-18000LM-SEF-AFL-GND-277-GZ10-40K-80CRI-DWHLED 18000LM4000 KELVIN-277105SURFACELED 2X2 HIGH BAY2' 6 BARF8ELITHONIA OR APPROVEDEQUALIBG-18000LM-SEF-AFL-GND-277-GZ10-40K-80CRI-DWH-IE20WCPHELED 18000LM4000 KELVIN-277105SURFACELED 2X2 HIGH BAY WITH BATTERY PACK2' 6 BARF9EATON OR APPROVEDEQUALISC-AF-1000-LED-E1-T3LED-27755WALLWALL PACKFINISH TO BE SELECTED BY ARCHITECTF10BY OWNERLED-27728WALLSCONCENOT TO EXCEED WATTAGE SHOWN. OWNER SELECTED.ELECTRICAL CONTRACTOR PROVIDE AND INSTALL.CONTRACTOR ALLOWANCE OF $300EGSURELITELITHONIAPROLITELSIDUAL-LITEMAXILUMESELW25XXAFN-DB-EXTDBEL-ACEM-W-SDT-CWCSN-DB-CTPGZ-HTRELM-807-BZ6W XENONINCLUDED227712SURFACEWALLEMERGENCY EGRESS LIGHTFINISH TO BE SELECTED BY ARCHITECTEM1SURELITELITHONIALIGHTOLIERLSIDUAL-LITEMAXILUMESEL17ELM2E611WLTEM-WHEZ-2ELM-LED-861INCLUDED22775.4SURFACEWALL2-HEAD EM WALL PACK (SURFACE)EX1SURELITELITHONIACHLORIDELSIDUAL-LITEMAXILUMEAPX7GLQM-S-W-3-G-EL-NER55L3WGEX-G-U-WB-WHEVEUGWEELX-603-G-WINCLUDED22771.5UNIVERSALUNIVERSAL MOUNT WITH EXTRA FACE PLATE FOR FIELDCONVERSION 1-2 FACENICKEL/CADMIUM BATTERYSINGLE FACE EXITSITE LIGHTING FIXTURE SCHEDULEFIXTFIXTURELAMPSPOLEREMARKS#MANUFACTURERCATALOG #VOLTS#/POLEWATTSMOUNTINGTYPEQTY/FIXT.MANUFACTURERHEIGHTCATALOG #SF1LUMARKPRV-XL - PA3A-740-UT3-BK-MS/DIM-L402771688POLELED4EXISTINGEXSTEXISTINGEXISTING ROUND POLELOAD CALCULATIONSGROSS BUILDING AREA:91,883SQ. FTBUILDING VOLTAGE:480VOLTSPHASE3PHASEOCCUPANCY TYPE:BUSINESSGENERAL LOADS:LIGHTING LOAD W/ 125% DEMAND: 45,489VARECEPTACLE LOAD: 42,120VAFIRST 10,000 VA @ 100% 10,000VAREMAINDER @50% 16,060VAADJUSTED RECEPTACLE TOTAL LOAD: 26,060VASMALL APPLIANCE LOAD: -VAKITCHEN EQUIPMENT -VAMISC: 2,900VATOTAL LOAD: 2,900VAHVAC LOADS:COOLING/HEATING 363,220VARESISTANCE HEATING: 3,000VAEXHAUST: -VAWATER HEATING: -VATOTAL: 366,220VAEQUIPMENT LOADS:MACHINERY: -VAELEVATOR: -VAPUMPS: -VAWELDERS: -VAAIR COMPRESSORS: -VAMOTORS -VANET COMPUTED LOAD 440,669VANET COMPUTED LOAD (VA ¸ VOLTS ):530AMPS 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMPANEL SCHEDULE "L"VOLTAGE:480Y/ 277 VOLTSBUS RATING (AMPS):125REMARKS:MOUNTING:SURFACEPHASE:3MAIN LUGS ONLYENCLOSURE:NEMA 1WIRE:4MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLECIRCUIT BREAKERCIRCUIT NAMEFEEDERCKT. LOADLOAD/PHASE (VA)CKT. LOADFEEDERCIRCUIT NAMECIRCUIT BREAKERNo.AMPSPOLEMOD.CWIREGRDDEMANDFACTORWATTSØAØBØCWATTSDEMANDFACTORGRDWIRECMOD.POLEAMPSNo.1201-ELEC ROOM-OFFICES-BREAK¾"#12#121.251,7764,2062,4301.25#12#12¾"STORE LTG-12023201-GOOSENECK LTG¾"#12#121.255942,2141,6201.25#12#12¾"STORE LTG-12045201-UNDER CANOPY LTG¾"#12#121.251,1664,6763,5101.25#12#12¾"STORE LTG-12067201-SIGN¾"#12#121.251,0004,2403,2401.25#12#12¾"STORE LTG-12089201-MAIN ENTRANCE¾"#12#121.254053,9153,5101.25#12#12¾"STORE LTG-1201011201-PATIO FLOOD LTG¾"#12#121.253763,3462,9701.25#12#12¾"STORE LTG-1201213201-MAIN ENTRANCE CANOPY¾"#12#121.251471,4971,3501.25#12#12¾"STORE LTG-1201415201-RESTROOMS LIGHT¾"#12#121.001,0003,8352,8351.25#12#12¾"STORE LTG-1201617-SPACE1.002,0252,0251.25#12#12¾"STORAGE LTG-1201819-SPACE1.0001.00SPACE-2021-SPACE1.0001.00SPACE-2223-SPACE1.0001.00SPACE-2425-SPACE1.0001.00SPACE-2627-SPACE1.0001.00SPACE-2829-SPACE1.0001.00SPACE-3031-SPACE1.0001.00SPACE-3233-SPACE1.0001.00SPACE-3435-SPACE1.0001.00SPACE-3637-SPACE1.0001.00SPARE-1203839-SPACE1.0001.00SPARE-1204041-SPACE1.0001.00SPARE-12042NOTES :1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØAØBØCTOTALSINSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.9,9439,96410,04729,954CONNECTED LOAD (VA)2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL36CONNECTED LOAD (A)ELECTRICAL CODE.2,4862,2412,5127,239DEMAND FACTOR ADJUSTMENTS (VA)3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT12,42912,20512,55937,193TOTAL LOAD (VA)LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL454445TOTAL LOAD (A)READ: "DANGER: POTENTIAL ARC FLASH HAZARD"45MAXIMUM LOAD (A)4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL33%33%34%PHASE BALANCEEFFICIENCY CERTIFICATES PER IECC R401.35.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELSSTATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST.LIGHTING CONTROL PANEL "LCP 1" SCHEDULEAUTOMATION SCHEDULEMOUNTING:SURFACELOCATION: RISER ROOMSchedule ON / OFFManual ON / Auto OFFDusk - DawnDusk - Auto OFF0-10V Dimming Phase Dimming Daylight SensorBRANCH CIRCUIT FOR CONTROL H-10SPACERELAYSUPPLYVAAREA SERVEDLV SWITCH* NUMBERAMPPOLE1201SPAREX2201H-6168FAÇADE SCONCEX3201H-2715WALL PACKX4201H-32,064PARKING LIGHTXX5201H-42,064PARKING LIGHTXX6201H-51,376PARKING LIGHTXX72010SPARE82010SPARE* SEE PLAN FOR LOCATION OF LOW VOLTAGE SWITCHLIGHTING CONTROL PANEL "LCP 2" SCHEDULEAUTOMATION SCHEDULEMOUNTING:SURFACELOCATION: ELECTRICAL ROOMSchedule ON / OFFManual ON / Auto OFFDusk - DawnDusk - Auto OFF0-10V Dimming Phase Dimming Daylight SensorBRANCH CIRCUIT FOR CONTROL H-10SPACERELAYSUPPLYVAAREA SERVEDLV SWITCH* NUMBERAMPPOLE1201L-22,430STOREaX2201L-41,620STOREbX3201L-63,510STOREcX4201L-83,240STOREdX5201L-103,510STOREeX6201L-122,970STOREfX7201L-141,350STOREgX8201L-162,835STOREhX9201L-3594GOOSENECKiX10201L-51,166UNDER CANOPYjX11201L-71,000BUILDING SIGNX12201L-9405MAIN ENTRANCEkX13201L-11376PATIO FLOOD LIGHTINGlX14201L-13147MAIN ENTRANCE EXTERIOR CANSmX152010SPARE162010SPARE172010SPARE182010SPARE192010SPARE202010SPARE* SEE PLAN FOR LOCATION OF LOW VOLTAGE SWITCHEQUIPMENT SCHEDULESYMBOLDESCRIPTIONSERVICEDISCONNECTSTARTERLOADREMARKSVOLTSPHASESIZEFUSEHP/TONVAAMPSRTU5ROOF TOP UNIT480 V3Ø30ANEMA 3R-INTEGRAL11,63914.0AFACTORY INSTALLED DISCONNECT AND RECEPTACLE. MOCP 20RTU10ROOF TOP UNIT480 V3Ø30ANEMA 3R-INTEGRAL23,27928.0AFACTORY INSTALLED DISCONNECT, RECEPTACLE, AND DUCTDETECTOR. MCCP 30EWH1ELECTRIC WALL HEATER120 V1ØT-STAT--1,50012.5AEF1EXHAUST FAN120 V1ØPLUG/CORD--1001.0ACONTROL EF WITH LIGHTINGEF2EXHAUST FAN120 V1ØPLUG/CORD--1401.2ACONTROL EF WITH LIGHTINGHP24HEAT PUMP208 V1ØMANUALSTARTER--4,16020.0AWM24FAIN COIL208 V1ØMANUALSTARTER--830.4ANOTES:1.VERIFY ALL EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS (i.e. VOLTAGE, PHASE, FLA, ETC.) WITH MECHANICAL DRAWINGS/SUBMITTALS BEFORE FOR ACTUAL EQUIPMENT INSTALLED.2.ALL FUSES SHALL BE DUAL ELEMENT TIME DELAY. FINAL BREAKER/FUSE & DISCONNECT SIZE SHALL BE DETERMINED BY MANUFACTURER'S RECOMMENDATION FOR ACTUAL EQUIPMENT INSTALLED.3.MAXIMUM VALUES INDICATED.4.DISCONNECTING MEANS NOT REQUIRED FOR EQUIPMENT WITHIN SIGHT (AS DEFINED IN NEC) OF BRANCH PANEL SERVING EQUIPMENT. SEE NEC 422.31 (B).5.DISCONNECTING MEANS NOT REQUIRED FOR APPLIANCES NOT OVER 300 VA. SEE NEC 422.31 (A).PANEL SCHEDULE "MDP"VOLTAGE:480Y/ 277 VOLTSBUS RATING (AMPS):800REMARKS:MOUNTING:SURFACEPHASE:3MAIN LUGS ONLYENCLOSURE:NEMA 1WIRE:4MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLECIRCUIT BREAKERCIRCUIT NAMEFEEDERCKT. LOADLOAD/PHASE (VA)CKT. LOADFEEDERCIRCUIT NAMECIRCUIT BREAKERNo.AMPSPOLEMOD.CWIREGRDDEMANDFACTORWATTSØAØBØCWATTSDEMANDFACTORGRDWIRECMOD.POLEAMPSNo.16003-PANEL M1½"1/0#61.00151,320163,74912,4291.00#6#11½"PANEL L-312523-----1/0-1.00151,320163,77512,4551.00-#1-----45-----1/0-1.00151,320163,87912,5591.00-#1-----673-SPACE1.0013,46013,4601.00#6#11½"TRANSFORMER X2-312589------1.0019,38019,3801.00-#1-----1011------1.0010,78010,7801.00-#1-----1213-SPACE1.0001.00SPACE-1415-SPACE1.0001.00SPACE-1617-SPACE1.0001.00SPACE-1819-SPACE1.0001.00SPACE-2021-SPACE1.0001.00SPACE-2223-SPACE1.0001.00SPACE-24NOTES :1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØAØBØCTOTALSINSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.177,209183,155174,659535,023CONNECTED LOAD (VA)2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL644CONNECTED LOAD (A)ELECTRICAL CODE.0000DEMAND FACTOR ADJUSTMENTS (VA)3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT177,209183,155174,659535,023TOTAL LOAD (VA)LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL639661630TOTAL LOAD (A)READ: "DANGER: POTENTIAL ARC FLASH HAZARD"661MAXIMUM LOAD (A)4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL33%34%33%PHASE BALANCEEFFICIENCY CERTIFICATES PER IECC R401.35.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELSSTATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST.FAULT CURRENT CALCULATION TABLEMAIN UTILITY COMPANY TRANSFORMER (ROCKYMOUNTAIN POWER)TRANSFORMER KVAAFC ATUTILITY%Z3Ø 277/480V -1200A PAD MOUNTED100020,846 A5.77%CONFIGURATIONFEEDERSYSTEMFAULT CURRENTAT EQUIPMENTFULL ORSERIESRATEDMINIMUMSYMMETRICALEQUIPMENT AICRATINGFROMTOLENGTHSOURCEFAULTCURRENTFEEDERSIZEFEEDERSPERPHASEWIRECONSTANTLINE TO LINEVOLTSXFMRSECONDARYVOLTSPHASEKVA%ZMOTORLOADTRANSFORMERUTILITYSWITCHBOARDMETER40'-0''20,846 AIC500 AL421,390480 V3Ø-20,138 AICFULL25,000 AICSWITCHBOARDMETERPANELBOARDH15'-0''20,138 AIC3 CU14,802480 V3Ø-16,412 AICFULL18,000 AICTRANSFORMERX1TRANS. SECONDARY20,138 AIC480 V208 V3Ø301.2%6,038 AICFULL14,000 AICTRANSFORMERX1PANELBOARDHP6'-0''6,038 AIC8 CU11,558208 V3Ø-5,058 AICFULL10,000 AICSWITCHBOARDMETERPANELBOARDMDP40'-0''20,138 AIC500 AL421,390480 V3Ø-19,476 AICFULL25,000 AICPANELBOARDMDPPANELBOARDM10'-0''19,476 AIC500 AL221,390480 V3Ø-19,161 AICFULL25,000 AICPANELBOARDMDPPANELBOARDL6'-0''19,476 AIC2/0 AL17,301480 V3Ø-18,413 AICFULL25,000 AICTRANSFORMERX2TRANS. SECONDARY20,138 AIC480 V208 V3Ø751.2%12,632 AICFULL14,000 AICTRANSFORMERX2PANELBOARDP6'-0''12,632 AIC250 AL112,862208 V3Ø-12,042 AICFULL22,000 AICSWITCHBOARDMETERPANELBOARDHS160'-0''20,138 AIC250 AL212,862480 V3Ø-13,869 AICFULL14,000 AICNOTE: DISTANCES INDICATED ARE FOR FAULT-CURRENT ANALYSIS ONLY. CONTRACTOR SHALL USE FIELD MEASUREMENTS ESTABLISH CONDUCTOR LENGTHS FOR ORDERING PURPOSES.PANEL SCHEDULE "P"VOLTAGE:208Y/ 120 VOLTSBUS RATING (AMPS):225REMARKS:MOUNTING:SURFACEPHASE:3MAIN CIRCUIT BREAKER:200ENCLOSURE:NEMA 1WIRE:4MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLECIRCUIT BREAKERCIRCUIT NAMEFEEDERCKT. LOADLOAD/PHASE (VA)CKT. LOADFEEDERCIRCUIT NAMECIRCUIT BREAKERNo.AMPSPOLEMOD.CWIREGRDDEMANDFACTORWATTSØAØBØCWATTSDEMANDFACTORGRDWIRECMOD.POLEAMPSNo.1201-ROOF RECPTS¾"#12#121.009001,6207201.00#12#12¾"ROOF RECPTS-12023201-RACK¾"#12#121.003607203601.00#12#12¾"RACK-12045201-IT ROOM RECEPTS¾"#12#121.003607203601.00#12#12¾"GUN ROOM RECEPTS-12067201-OFFICE 108 RECEPTS¾"#12#121.007201,4407201.00#12#12¾"OFFICE 109 RECEPTS-12089601-KEY MACHINE1"#6#101.005,0005,5405401.00#12#12¾"THEF DETERRANT-1201011201-REGISTER RECEPT¾"#12#121.003609005401.00#12#12¾"HALL 107 RECEPTS-1201213201-DRINKING FOUNTAIN¾"#12#121.003601,0807201.00#12#12¾"BREAK ROOM RECEPTS-1201415201GFCIREFRIGERATOR¾"#12#121.001,0002,8001,8001.00#12#12¾"MICROWAVE-1201617201-COUNTER RECEPT¾"#12#121.005001,0005001.00#12#12¾"COUNTER RECEPT-1201819201-COUNTER RECEPT¾"#12#121.005001,0005001.00#12#12¾"DISPOSALGFCI1202021201-STORAGE 105 RECEPTS¾"#12#121.009001,4405401.00#12#12¾"STORAGE 105 RECETS-1202223201-EXISTING RESTROOM RECT¾"#12#121.003601,6201,2601.00#12#12¾"CASH WRAP RECEPT-1202425201-EXISTING RESTROOM RECT¾"#12#121.003601,3601,0001.00#12#12¾"PROPINEGFCI1202627201-DROP RECEPT¾"#12#121.005401,0405001.00#12#12¾"EXTERIOR PATIO RECPTGFCI2202829201-COMM BOARD¾"#12#121.003608605001.00-#12-----3031201-EWH¾"#12#121.001,5002,5001,0001.00#12#12¾"THEF DETERRANT-1203233201-RESTROOM RECEPTS¾"#12#121.003601,3601,0001.00#12#12¾"SLIDING DOORS-1203435201-SLIDING DOORS¾"#12#121.001,0001,3603601.00#12#12¾"REGISTER RECEPT-1203637201-ROLLING DOOR¾"#12#121.005008603601.00#12#12¾"DROP RECEPTS-1203839201-WALL RECEPTS¾"#12#121.001,4402,5201,0801.00#12#12¾"MAIN ENTRACE RECPTS-1204041201-EXETRIOR RECEPT¾"#12#121.001803601801.00#12#12¾"EXTERIOR RECEPT-1204243201-DROP RECEPT¾"#12#121.001807205401.00#12#12¾"DROP RECEPTS-1204445201-CHICK READERS¾"#12#121.005401,2607201.00#12#12¾"WALL RECEPTS-1204647201-CEILING RECEPTS¾"#12#121.009001,6207201.00#12#12¾"WALL RECEPTS-1204849201-COLUMNS RECEPT¾"#12#121.001,0801,6205401.00#12#12¾"DROP RECEPTS-1205051201-COLUMNS RECEPT¾"#12#121.001,0801,4403601.00#12#12¾"DROP RECEPTS-1205253201-COLUMNS RECEPT¾"#12#121.001,2601,6203601.00#12#12¾"DROP RECEPTS-1205455201-DRESSING RECEPTS¾"#12#121.003601,2609001.00#12#12¾"COLUMNS RECEPT-1205657201REDNAC¾"#12#121.005001,5801,0801.00#12#12¾"COLUMNS RECEPT-1205859201REDANN¾"#12#121.005001,2207201.00#12#12¾"WALL RECEPTS-1206061302-HP-24¾"#10#101.002,0802,0801.00SPACE-6263-----#10-1.002,0802,0801.00SPACE-6465202-WM¾"#12#121.0042421.00SPACE-6667-----#12-1.0042421.00SPACE-6869-SPACE1.0001.00SPACE-7071-SPACE1.0001.00SPACE-7273-SPACE1.0001.00SPACE-7475-SPACE1.0001.00SPACE-7677201-SPARE1.0001.00SPACE-7879201-SPARE1.0001.00SPACE-8081201-SPARE1.0001.00SPACE-8283201-SPARE1.0001.00SPACE-84NOTES :1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØAØBØCTOTALSINSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.15,58221,78011,32248,684CONNECTED LOAD (VA)2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL135CONNECTED LOAD (A)ELECTRICAL CODE.0000DEMAND FACTOR ADJUSTMENTS (VA)3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT15,58221,78011,32248,684TOTAL LOAD (VA)LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL13018194TOTAL LOAD (A)READ: "DANGER: POTENTIAL ARC FLASH HAZARD"181MAXIMUM LOAD (A)4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL32%45%23%PHASE BALANCEEFFICIENCY CERTIFICATES PER IECC R401.35.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELSSTATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST.PANEL SCHEDULE "M"VOLTAGE:480Y/ 277 VOLTSBUS RATING (AMPS):600REMARKS:MOUNTING:SURFACEPHASE:3MAIN CIRCUIT BREAKER:ENCLOSURE:NEMA 1WIRE:4MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLECIRCUIT BREAKERCIRCUIT NAMEFEEDERCKT. LOADLOAD/PHASE (VA)CKT. LOADFEEDERCIRCUIT NAMECIRCUIT BREAKERNo.AMPSPOLEMOD.CWIREGRDDEMANDFACTORWATTSØAØBØCWATTSDEMANDFACTORGRDWIRECMOD.POLEAMPSNo.1303-RTU-10a¾"#10#101.007,76015,5207,7601.00#10#10¾"RTU-10b-33023-----#10-1.007,76015,5207,7601.00-#10-----45-----#10-1.007,76015,5207,7601.00-#10-----67303-RTU-10c¾"#10#101.007,76015,5207,7601.00#10#10¾"RTU-10d-33089-----#10-1.007,76015,5207,7601.00-#10-----1011-----#10-1.007,76015,5207,7601.00-#10-----1213303-RTU-10e¾"#10#101.007,76015,5207,7601.00#10#10¾"RTU-10f-3301415-----#10-1.007,76015,5207,7601.00-#10-----1617-----#10-1.007,76015,5207,7601.00-#10-----1819303-RTU-10g¾"#10#101.007,7607,7601.00SPACE--2021-----#10-1.007,7607,7601.00SPACE--2223-----#10-1.007,7607,7601.00SPACE--2425303-RTU-10i¾"#10#101.007,76015,5207,7601.00#10#10¾"RTU-10j-3302627-----#10-1.007,76015,5207,7601.00-#10-----2829-----#10-1.007,76015,5207,7601.00-#10-----3031303-RTU-10k¾"#10#101.007,76015,5207,7601.00#10#10¾"RTU-10l-3303233-----#10-1.007,76015,5207,7601.00-#10-----3435-----#10-1.007,76015,5207,7601.00-#10-----3637303-RTU-10m¾"#10#101.007,7607,7601.00SPACE-30-3839-----#10-1.007,7607,7601.00SPACE--4041-----#10-1.007,7607,7601.00SPACE--4243--SPACE1.007,7607,7601.00#10#10¾"RTU-10p-3304445--SPACE1.007,7607,7601.00-#10-----4647--SPACE1.007,7607,7601.00-#10-----4849--SPACE1.007,7607,7601.00#10#10¾"RTU-10r-3305051--SPACE1.007,7607,7601.00-#10-----5253--SPACE1.007,7607,7601.00-#10-----5455303-RTU-10s¾"#10#101.007,76011,6403,8801.00#12#12¾"RTU-5-3205657-----#10-1.007,76011,6403,8801.00-#12-----5859-----#10-1.007,76011,6403,8801.00-#12-----6061---SPACE-#10-1.0001.00SPACE-6263-SPACE1.0001.00SPACE-6465-SPACE1.0001.00SPACE-6667-SPACE1.0001.00SPACE-6869-SPACE1.0001.00SPACE-7071-SPACE1.0001.00SPACE-7273-SPACE1.0001.00SPACE-7475-SPACE1.0001.00SPACE-7677-SPACE1.0001.00SPACE-7879-SPACE1.0001.00SPACE-8081-SPACE1.0001.00SPACE-8283-SPACE1.0001.00SPACE-84NOTES :1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØAØBØCTOTALSINSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.120,280120,280120,280360,840CONNECTED LOAD (VA)2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL434CONNECTED LOAD (A)ELECTRICAL CODE.0000DEMAND FACTOR ADJUSTMENTS (VA)3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT120,280120,280120,280360,840TOTAL LOAD (VA)LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL434434434TOTAL LOAD (A)READ: "DANGER: POTENTIAL ARC FLASH HAZARD"434MAXIMUM LOAD (A)4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL33%33%33%PHASE BALANCEEFFICIENCY CERTIFICATES PER IECC R401.35.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELSSTATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMCOPPER & ALUMINUM FEEDER SCHEDULEEQUIPMENT GROUNDINGCONDUCTORS SCHEDULETRENCHING DETAIL1POWER ONE-LINE DIAGRAM - TENANT 3KEYED NOTES:2COMMUNICATIONS RISER DIAGRAM TYP. 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMLIGHT/FAN INTERPOSING RELAY WIRING DIAGRAM9DEVICE MOUNTING HEIGHTS INSTALLATION DETAIL4LIGHTING CONTROL PANEL WIRING DIAGRAMKEYED NOTE:10"LCP"TYPICAL RECESSED FIXTURE MOUNTING DETAIL5KEYED NOTES:ELECTRICAL EQUIPMENT WORK SPACE CLEARANCESGENERAL NOTE:11ROUGH-IN DETAIL FOR CONDUITGENERAL NOTES:7TYPICAL SUSPENDED FIXTURE MOUNTING DETAIL6ROUGH-IN DETAIL FOR MC CABLEKEYED NOTES:GENERAL NOTES:8 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMTRENCHING DETAIL18WEATHERPROOF RECEPTACLE INSTALLATION DETAIL19ELECTRIC WATER COOLER INSTALLATION DETAILREGULARACCESSIBLE16WALL PENETRATIONFLOOR PENETRATIONFIRE RATED PENETRATION DETAIL14DATA/VOICE JACK INSTALLATION DETAILELECTRICAL GENERAL NOTES:20ROOF PENETRATION DETAIL15FIRE ALARM RISER DIAGRAM12FACPRFAANOTES:MOTION SENSOR WITH LV SWITCH1713TYPICAL DROP CORD DETAIL 5ABCE4321D6SHEET:DATE:PROJECT #:PROJ. MAN.:CHECKED BY:MARKSHEET DESCRIPTION:PROJECT:REVISIONDATETHE INFORMATION HEREIN IS THE PROPERTY OFDALLAS NELSON ARCHITECTURE, INC. AND MAYNOT BE REPRODUCED WITHOUT WRITTENCONSENT. © 2020 D.N.A., INC.801-953-3294 DALNELSON21@HOTMAIL.COM1912 CONCORD PLACESARATOGA SPRINGS, UT 84045530 N. 2ND EASTREXBURG, IDAHO7 DECEMBER, 202020-18MLMTHESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991).COPYRIGHT©JOB#DATE PLOTTED:12/29/2020MECHANICALPROVO, UTAH 84606FAX: 801.375.2676ELECTRICAL1837 S. EAST BAY BLVD.PHONE: 801.375.2228J20336.00MMRBMMELECTRICAL SPECIFICATIONSGENERAL PROVISIONA.REFERENCE1.THE GENERAL CONDITIONS AND OTHER CONTRACT DRAWINGS AS SET FORTH IN THE FOREGOING PAGESARE HEREBY INCORPORATED INTO AND BECOME A PART OF THE SPECIFICATIONS FOR WORK UNDER THISTITLE, INSOFAR AS THEY APPLY HERETO.2.ALL SPECIFICATIONS UNDER THIS DIVISION TITLE ARE DIRECTED TO AND ARE THE RESPONSIBILITY OF THEELECTRICAL CONTRACTOR, UNLESS OTHER TRADES OR PERSONS ARE SPECIFICALLY MENTIONED,“ELECTRICAL CONTRACTOR” IS INFERRED AND INTENDED.B.CONTRACT DRAWINGS1.THE DRAWINGS ACCOMPANYING THESE SPECIFICATIONS ARE COMPLEMENTARY EACH TO THE OTHER ANDWHAT IS CALLED FOR BY ONE SHALL BE AS IF CALLED FOR BY BOTH.2.CONSULT ALL CONTRACT DRAWINGS WHICH MAY AFFECT THE LOCATION OF EQUIPMENT, CONDUIT ANDWIRING AND MAKE MINOR ADJUSTMENTS IN LOCATION TO SECURE COORDINATION.3.WIRING LAYOUT IS SCHEMATIC AND EXACT LOCATIONS SHALL BE DETERMINED BY FIELD CONDITIONS.4.OTHER THAN MINOR ADJUSTMENTS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FORAPPROVAL BEFORE PROCEEDING WITH THE WORK.C.JOB-SITE COPY OF DOCUMENTS1.MAINTAIN AT THE SITE, ONE COPY OF ALL DRAWINGS, SPECIFICATIONS, ADDENDA APPROVED SHOPDRAWINGS, CHANGE ORDERS AND OTHER MODIFICATIONS, IN GOOD ORDER AND MARKED TO RECORD ALLCHANGES MADE DURING CONSTRUCTION. THESE SHALL BE AVAILABLE TO THE OWNER'S REPRESENTATIVE.THE DRAWINGS MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION SHALL BE DELIVERED TOTHE OWNER'S REPRESENTATIVE FOR THE OWNER UPON COMPLETION OF THE WORK. AN ADDITIONAL SET OFDRAWINGS WILL BE FURNISHED BY THE OWNER'S REPRESENTATIVE FOR THIS PURPOSE UPON REQUEST.D.MANUFACTURER'S DRAWINGS1.THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT FOR REVIEW. (6) COPIES OF MANUFACTURER'SDRAWINGS AND WIRING DIAGRAMS. THE ENGINEER WILL REVIEW CONTRACTOR'S SHOP DRAWINGS ANDRELATED SUBMITTALS (AS INDICATED BELOW) WITH RESPECT TO THE ABILITY OF THE DETAILED WORK, WHENCOMPLETE, TO BE A PROPERLY FUNCTIONING INTEGRAL ELEMENT OF THE OVERALL SYSTEM DESIGNED BYTHE ENGINEER. BEFORE SUBMITTING A SHOP DRAWING OR ANY RELATED MATERIAL TO THE ENGINEER,CONTRACTOR SHALL: REVIEW EACH SUCH SUBMISSION FOR CONFORMANCE WITH THE MEANS, METHODS,TECHNIQUES, SEQUENCES,AND OPERATIONS OF CONSTRUCTION, AND SAFETY PRECAUTIONS ANDPROGRAMS INCIDENTAL THERETO, ALL OF WHICH ARE THE SOLE RESPONSIBILITY OF CONTRACTOR:APPROVE EACH SUCH SUBMISSION BEFORE SUBMITTING IT; AND SO STAMP EACH SUCH SUBMISSION BEFORESUBMITTING IT. THE ENGINEER SHALL ASSUME THAT NO SHOP DRAWING OR RELATED SUBMITTALCOMPRISES A VARIATION UNLESS CONTRACTOR ADVISES ENGINEER OTHERWISE VIA A WRITTENINSTRUMENT WHICH IS ACKNOWLEDGED BY ENGINEER IN WRITING. THE ITEMS, TYPES OF SUBMITTALS ANDRELATED MATERIAL (IF ANY) CALLED FOR ARE INDICATED BELOW:ITEMSTYPE SUBMITTALS REQUESTEDLIGHTING AND POWER PANELSSHOP DRAWINGSLIGHTING FIXTURESCATALOG CUTSE.GUARANTEES1.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEFECTS, REPAIRS AND REPLACEMENTS INMATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF SUBSTANTIAL COMPLETIONAS DETERMINED BY THE OWNER'S REPRESENTATIVE. PRODUCT GUARANTEES GREATER THAN ONE (1) YEARSHALL BE PASSED ALONG TO THE OWNER FOR FULL BENEFIT OF THE MANUFACTURER'S WARRANTY.WORK INCLUDEDA.INSTALLATION, MATERIALS, AND WORKMANSHIP1.FURNISH AND INSTALL ALL NECESSARY ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS AND OTHERSIMILAR APPURTENANCES NOT INDICATED ON THE DRAWINGS BUT WHICH ARE REQUIRED FOR A COMPLETEAND PROPERLY INSTALLED SYSTEM CONSISTENT WITH THE ARCHITECTURAL TREATMENT OF THE BUILDING.2.THE ELECTRICAL CONTRACTOR, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THEPREMISES IN A NEAT AND ORDERLY CONDITION. AND AT THE COMPLETION OF THE WORK, SHALL PROPERLYCLEAN UP AND CART AWAY DEBRIS AND EXCESS MATERIALS. ELECTRICAL CONTRACTOR SHALL BERESPONSIBLE FOR THE COST OF DUMPSTER & REFUSED DISPOSAL AS REQUIRED FOR ELECTRICAL WORK.3.ALL MATERIALS SHALL BE NEW AND UNDETERIORATED AND OF A QUALITY NOT LESS THAN THE MINIMUMSPECIFIED.B.COORDINATION OF PLANS AND SPECIFICATIONS1.CONTACT THE OWNER'S REPRESENTATIVE IMMEDIATELY IF THERE IS ANY QUESTIONS REGARDING THEMEANING OR INTENT OF EITHER PLANS OR SPECIFICATIONS, OR UPON NOTICING ANY DISCREPANCIES OROMISSIONS IN EITHER PLANS OR SPECIFICATIONS.C.CUTTING AND PATCHING1.ALL ELECTRICAL EQUIPMENT SHALL BE KEPT DRY AND CLEAN DURING THE CONSTRUCTION PERIOD.INTERIOR OF ALL ENCLOSURES SHALL BE CLEANED OF DIRT AND DEBRIS BEFORE INSTALLING TRIM ORCOVERS.2.ALL FINISHED SURFACES OF EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE THOROUGHLYCLEANED OF DIRT AND ALL SCRATCHED OR DAMAGED SURFACES SHALL BE TOUCHED UP WITH MATCHINGMATERIALS BEFORE FINAL ACCEPTANCE OF THE WORK.3.WHEN ALL WORK IS COMPLETED AND ALL WORK HAS BEEN SATISFACTORILY TESTED AND ACCEPTED BY THEOWNER'S REPRESENTATIVE, ALL CONDUIT AND OTHER EXPOSED SURFACES SHALL BE THOROUGHLYCLEANED.CODES AND FEESA.CODES:1.ALL WORK PERFORMED UNDER THIS SPECIFICATION SHALL BE DONE IN ACCORDANCE WITH THE LATESTEDITION OF THE NATIONAL ELECTRICAL CODE AS PREPARED AND PUBLISHED BY THE NATIONAL FIREPROTECTION ASSOCIATION AND ANY APPLICABLE STATE OR LOCAL CODES.B.FEES:1.OBTAIN AND PAY FOR ANY AND ALL PERMITS REQUIRED BY ALL LAWS AND REGULATIONS AND PUBLICAUTHORITY HAVING SUCH JURISDICTION.TESTS AND INSPECTIONSA.OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES, RULES, REGULATIONS OR PUBLIC AUTHORITYHAVING JURISDICTION AND OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE OWNER'SREPRESENTATIVE. PAY ALL FEES, CHARGES AND OTHER EXPENSES IN CONNECTION THEREIN. OBTAINOCCUPANCY PERMIT AS REQUIRED BY OWNER. FINAL PAYMENT SHALL NOT BE MADE UNTIL OCCUPANCY PERMITIS OBTAINED.B.WORK SHALL BE UNACCEPTABLE WHEN FOUND TO BE DEFECTIVE OR CONTRARY TO THE PLANS SPECIFICATIONS,CODES SPECIFIED OR ACCEPTED STANDARDS OF GOOD WORKMANSHIP.C.THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK FOUND UNACCEPTABLE BY THE OWNER'SREPRESENTATIVE WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND WHETHER OR NOTFABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL BEAR ALL COSTS OF CORRECTING SUCHUNACCEPTABLE WORK, INCLUDING COMPENSATION FOR THE OWNERS REPRESENTATIVE ADDITIONAL SERVICESMADE NECESSARY THEREBY.CONDUITA.FURNISH AND INSTALL ALL CONDUITS, BOXES, FITTINGS, ETC., FOR A COMPLETE RACEWAY SYSTEM.B.ALL WIRING SHALL BE RUN IN EMT CONDUIT OR MC CABLE WITH GROUND CONDUCTOR UNLESS OTHERWISENOTED.C.ALL CONDUIT SIZES STATED HEREIN OR MARKED ON THE DRAWINGS ARE MINIMUM SIZE AND SHALL BE NO LESSTHAN 12" UNLESS OTHERWISE NOTED.D.ALL CONDUIT SHALL BE SUBSTANTIALLY SUPPORTED BY PIPE STRAPS OR SUITABLE CLAMPS OR HANGERSATTACHED TO THE ELEMENTS OF THE BUILDING STRUCTURE TO PROVIDE RIGID INSTALLATION; IN NO CASE SHALLCONDUIT BE ATTACHED OR SUPPORTED FROM ADJOINING PIPE OR INSTALLED IN SUCH A MANNER AS TOPREVENT THE READY REMOVAL OF OTHER PIPE FOR REPAIRS.WIRE AND CABLEA.ALL CONDUCTORS SHALL BE COPPER AND OF THE AWG SIZE AND TYPE SHOWN ON THE DRAWINGS. WHERE NOSIZE OR TYPE IS SHOWN. CONDUCTORS SHALL NOT BE LESS THAN #12 TYPE XHHW, THHN, OR THWN.CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED COPPER AND HAVE 600 VOLT INSULATION; BE ULLABELED AND OF AMERICAN MANUFACTURER.B.ALL CONNECTIONS ARE TO BE MADE USING PRESSURE TYPE TERMINALS.C.THE FOLLOWING COLOR CODE SHALL BE USED:120/240 VOLT120/208 VOLT277/480 VOLTPHASE ABLACKBLACKBROWNPHASE BREDREDORANGEPHASE CBLUEYELLOWNEUTRALWHITEWHITEWHITEGROUNDGREENGREENGREEND.CONDUCTORS NO. 10 AWG OR SMALLER SHALL HAVE INSULATION COLORED AS NOTED ABOVE.E.CONDUCTORS NO. 8 AWG OR LARGER SHALL HAVE INSULATION COLORED AS NOTED ABOVE OR COLORED TAPE,MINIMUM SIZE 12'', WRAPPED TWICE AROUND AT THE FOLLOWING POINTS:1.AT EACH TERMINAL.2.AT EACH CONDUIT ENTRANCE.3.AT INTERVALS NOT MORE THAN 12 INCHES APART IN ALL BOXES, PANEL TUBS, SWITCHBOARDS, ETC.G.ALL BRANCH CIRCUITS SHALL BE MARKED IN THE PANEL BOARD GUTTERS. MARKERS SHALL INDICATECORRESPONDING BRANCH--CIRCUIT NUMBERS.H.EACH BRANCH CIRCUIT REQUIRING A NEUTRAL SHALL BE FURNISHED WITH A SEPARATE INDIVIDUAL NEUTRALCONDUCTOR.BOXES AND PLATESA.FURNISH AND INSTALL ALL OUTLET, JUNCTION, AND PULL BOXES AS INDICATED ON THE DRAWINGS AND ASNECESSARY TO INSTALL THE REQUIRED CONDUIT AND WIRING IN A NEAT AND WORKMANLIKE MANNER.B.PULL BOXES AND JUNCTION BOXES SHALL BE GALVANIZED AND OF THE CORRECT SIZE AND GAUGE, SIZED INACCORDANCE WITH CODE REQUIREMENTS AND SHALL BE U.L. LABELED.C.BOXES AT EXTERIOR AREAS TO BE WATERTIGHT AND DUST-TIGHT WITH CASKETED COVERS.D.ALL BOXES FOR EXPOSED WORK IN FINISHED SPACES SHALL BE ''FS'' TYPE WITH THREADED HUBS WITH RIGIDCONDUIT RISER (DEEP WIRE MOLD BOXES).E.ALL BOXES SHALL BE RIGIDLY SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. BOXES CAST INTO MASONRYOR CONCRETE ARE CONSIDERED TO BE RIGIDLY SUPPORTED.F.FLOOR BOXES:1.DESCRIPTION: FLOOR BOXES COMPATIBLE WITH FLOOR BOX SERVICE FITTINGS PROVIDED IN ACCORDANCEWITH THE WIRING DEVICES SECTION OF THIS SPECIFICATION; WITH PARTITIONS TO SEPARATE MULTIPLESERVICES; FURNISHED WITH ALL COMPONENTS, ADAPTERS, AND TRIMS REQUIRED FOR COMPLETEINSTALLATION.2.USE CAST IRON OR NONMETALLIC FLOOR BOXES WITHIN SLAB ON GRADE.3.USE SHEET-STEEL, CAST IRON, OR NONMETALLIC FLOOR BOXES WITHIN SLAB ABOVE GRADE.4.METALLIC FLOOR BOXES: FULLY ADJUSTABLE (WITH INTEGRAL MEANS FOR LEVELING ADJUSTMENT PRIOR TOAND AFTER CONCRETE POUR).5.MANUFACTURER: SAME AS MANUFACTURER OF FLOOR BOX SERVICE FITTINGS.G.UNDERGROUND BOXES/ENCLOSURES:1.DESCRIPTION: IN-GROUND, OPEN BOTTOM BOXES FURNISHED WITH FLUSH, NON-SKID COVERS WITH LEGENDINDICATING TYPE OF SERVICE AND STAINLESS STEEL TAMPER RESISTANT COVER BOLTS.2.SIZE: AS INDICATED ON DRAWINGS.3.DEPTH: AS REQUIRED TO EXTEND BELOW FROST LINE TO PREVENT FROST UPHEAVAL, BUT NOT LESS THAN12 INCHES.4.APPLICATIONS:a.SIDEWALKS AND LANDSCAPED AREAS SUBJECT ONLY TO OCCASIONAL NONDELIBERATE VEHICULARTRAFFIC: USE POLYMER CONCRETE OR COMPOSITE ENCLOSURE WITH MINIMUM SCTE 77, TIER 8 LOADRATING.b.PARKING LOTS, IN AREAS SUBJECT ONLY TO OCCASIONAL NONDELIBERATE VEHICULAR TRAFFIC: USEPOLYMER CONCRETE OR COMPOSITE ENCLOSURE WITH MINIMUM SCTE 77, TIER 15 LOAD RATING.c.DO NOT USE POLYMER CONCRETE ENCLOSURES IN AREAS SUBJECT TO DELIBERATE VEHICULARTRAFFIC.H.COMPOSITE UNDERGROUND BOXES/ENCLOSURES: COMPLY WITH SCTE 77.WIRING DEVICESA.WIRING DEVICES SHALL BE SIMILAR TO THOSE LISTED BELOW AND OF SPECIFIED AMPERAGE. OTHER SPECIALPURPOSE DEVICES SHALL BE AS SPECIFIED ON THE DRAWINGS.B.DUPLEX GROUNDING TYPE RECEPTACLE - 20 AMP, 125 VOLT1.HUBBELL 53522.ARROW HART 5352C.SINGLE POLE SWITCHES - 20 AMP, 120 VOLTD.WEATHERPROOF RECEPTACLES - 20 AMP, 125 VOLT - NEMA 5-20R1.HUBBELL 5352 WITH 5205 COVER INTERMATIC GUARDIAN2.I SERIES, NEMA 3R COVER3.ARROW HART 5352 WITH 4500 COVERE.G.F.C.I. RECEPTACLE - 20 AMP, 125 VOLT - NEMA 5-20 R1.HUBBELL GF 5262 WITH MATCHING NYLON COVER PLATE OR WO-26 W.P. COVERF.GROUND ALL RECEPTACLES IN ACCORDANCE WITH ARTICLE 250.146 OF NEC AND AS INDICATED IN THEGROUNDING SECTION OF THIS SPECIFICATION.IDENTIFICATIONA.EACH PIECE OF SERVICE EQUIPMENT AND INDIVIDUAL SWITCHES, ALL DISCONNECTS, STARTERS, ALL EXHAUSTFAN MANUAL STARTING SWITCHES.B.IDENTIFICATION SHALL BE IN THE FORM OF LAMINATED PLASTIC NAMEPLATES, BLACK RACE, WITH THE LETTERSENGRAVED INTO THE WHITE BACKGROUND, MINIMUM ¼'' HIGH. PLATES SHALL BE DRILLED ON EACH END FORSHEET METAL SCREW ATTACHMENT. NO “DYMO” OR SIMILAR TYPE LABELS WILL BE ALLOWED.C.PANEL BOARD DIRECTORY: A TYPED CIRCUIT DIRECTORY SHALL BE PROVIDED INDICATING LOCAL AREA SERVEDAND LOCATION FOR EACH BRANCH CIRCUIT.GROUNDINGA.ALL FEEDERS AND BRANCH CIRCUITS OVER 100 VOLTS SHALL INCLUDE A GROUNDING CONDUCTOR SIZED INACCORDANCE WITH NEC TABLE 250-122, EXCEPT NOT BE SMALLER THAN #12 FOR POWER AND LIGHTING CIRCUITSAND #14 FOR CONTROL CIRCUITS. ALL GROUND CONDUCTORS SHALL BE GREEN, OR AS SPECIFIED UNDER THEWIRE AND CABLE SECTION OF THIS SPECIFICATION.B.ALL GROUND CLAMPS SHALL BE PENN-UNION “GPL” TYPE OR SIMILAR BY O.Z. OR BURNDY.C.CONDUIT FOR SOLITARY GROUND CONDUCTORS SHALL BE RIGID SCHEDULE 40 PVC NON- METALLIC ELECTRICALCONDUIT WITH U.L. LABEL SOLITARY GROUND CONDUCTORS SHALL NOT BE PLACED THROUGH METALLICSLEEVES OR CONDUITS AND SHALL NOT BE COMPLETELY ENCIRCLED BY METALLIC HANGERS OR SUPPORTS.D.THE GROUND CONDUCTOR SHALL BE CONNECTED TO THE NEUTRAL IN ONLY TWO LOCATIONS -ON THE SUPPLYSIDE OF THE SERVICE DISCONNECT MEANS PER NEC--250--24 AND ON SEPARATELY DERIVED SYSTEMS PER NEC250-30.E.AT EACH RECEPTACLE BOX, THE GROUND CONDUCTOR SHALL ENTER AND CONNECT, WITH NORMAL WIRINGCONNECTOR, TO: 1) THE GROUND PIGTAIL TO RECEPTACLE: 2) THE GROUND PIGTAIL TO THE BOX GROUNDSCREW; AND 3) THE OUTGOING GROUND CONDUCTOR TO NEXT DEVICE, IF NOT AT END OF RUN. METAL TO METALCONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHERSURFACE. MOUNTED BOXES OR FLUSH TYPE BOXES.F.CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS SHALL CUT THROUGH ENAMELED ORPAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON-CURRENT CARRYING METALS AREISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. WHERE REDUCINGWASHERS ARE USED AND WHERE CONCENTRIC OR ECCENTRIC KNOCKOUTS ARE NOT COMPLETELY REMOVEDBONDING BUSHINGS SHALL BE REQUIRED.POWER AND LIGHTING PANELSA.FURNISH AND INSTALL, AS SCHEDULED AND SHOWN ON THE DRAWINGS, POWER PANELS FOR OPERATION ONVOLTAGES INDICATED.B.ALL TERMINATIONS SHALL BE MARKED “75°C ONLY”, “60/75° C” OR LISTED FOR USE OF 75° C INSULATEDCONDUCTORS AT FULL 75° C AMPACITY.C.ALL BUS BARS SHALL BE SILVER OR TIN PLATED COPPER.D.CABINETS SHALL BE OF COMMERCIAL GALVANIZED SHEET STEEL, CODE GAUGE AND SIZE, SURFACE ORRECESSED MOUNTED AS CALLED FOR IN THE DRAWINGS.E.NEUTRAL ASSEMBLY SHALL HAVE INDIVIDUAL ANTI-TURN SOLDERLESS TERMINALS, SIMILAR TO SQUARE D TYPEPK, FOR CONNECTION OF ULTIMATE NUMBER OF NEUTRAL WIRES. SHEET METAL TERMINAL STRIPS ANDCONNECTIONS WILL BE REJECTED.F.PANEL SHALL HAVE A COPPER GROUND BAR SIMILAR TO NEUTRAL BAR IN NUMBER, SIZE, AND TYPE OF ANTI-TURNSOLDERLESS LUGS. THIS GROUND BAR SHALL BE FACTORY BONDED TO THE PANEL TUB IN THE GUTTER SPACEOPPOSITE THE MAINS AND THE NEUTRAL ASSEMBLY AND SHALL HAVE THE SCREWDRIVER SLOTS FACING THEFRONT OF THE PANEL.G.QUALITY STANDARD: SQUARE D TYPE NQ (208V) OR NF (480V).LIGHTING FIXTURESA.CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES AS INDICATED IN FIXTURE SCHEDULE SHOWN ONDRAWINGS, AND SPECIFIED HEREIN.B.NEUTRAL ASSEMBLY SHALL HAVE INDIVIDUAL ANTI-TURN SOLDERLESS TERMINALS, SIMILAR TO SQUARE D TYPEPK, FOR CONNECTION OF ULTIMATE NUMBER OF NEUTRAL WIRES. SHEET METAL TERMINAL STRIPS ANDCONNECTIONS WILL BE REJECTED.C.ALL LIGHTING FIXTURES INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE FURNISHED COMPLETE WITH ASINDICATED ON THE FIXTURE SCHEDULE.D.ANY LIGHTING FIXTURES SCRATCHED, BENT, CRACKED OR IN ANY WAY DAMAGED BEFORE ACCEPTANCE BYOWNER SHALL BE REPLACED AT THIS CONTRACTOR'S EXPENSE.E.ALL LIGHTING FIXTURES SHALL BE IN WORKING ORDER AT THE TIME OF FINAL ACCEPTANCE OF THE WORK BY THEOWNER.F.ALL LIGHTING FIXTURES ARE TO BE GROUNDED ON THE INTERIOR OF THE FIXTURE HOUSING, ON CLEAN BAREMETAL (FREE OF PAINT). BY USE OF PIGTAIL AND FASTENED BY A SCREW USED FOR NO OTHER PURPOSE.ALARM & DETECTION SYSTEMSA.SUMMARY1.INCLUDES BUT NOT LIMITED TO: FURNISH AND INSTALL MICROPROCESSOR-CONTROLLED, INTELLIGENTREPORTING FIRE ALARM EQUIPMENT REQUIRED TO FORM A COMPLETE COORDINATED SYSTEM THAT ISREADY FOR OPERATION.B.SYSTEM DESCRIPTION1.THE FIRE ALARM SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA STANDARD NO. 72 FOR PROTECTEDPREMISES SIGNALING SYSTEMS EXCEPT AS MODIFIED AND SUPPLEMENTED BY THIS SPECIFICATION. THESYSTEM SHALL BE ELECTRICALLY SUPERVISED AND MONITOR THE INTEGRITY OF ALL CONDUCTORS.2.THE SYSTEM SHALL BE AN ACTIVE/INTERROGATIVE TYPE SYSTEM WHERE EACH DEVICE IS REPETITIVELYSCANNED, CAUSING A SIGNAL TO BE TRANSMITTED TO THE MAIN FIRE ALARM CONTROL PANEL (FACP)INDICATING THAT THE ASSOCIATED INITIATING DEVICE AND NOTIFICATION APPLIANCE CIRCUIT WIRING ISFUNCTIONAL. LOSS OF SUCH A SIGNAL AT THE MAIN FACP SHALL RESULT IN A TROUBLE INDICATION ASSPECIFIED HEREINAFTER FOR THE PARTICULAR INPUT.3.SYSTEM OPERATION: OPERATION OF MANUAL STATION OR AUTOMATIC ACTIVATION OF ANY SMOKEDETECTOR OR HEAT DETECTOR SHALL:a.CAUSE SYSTEM EVACUATION HORNS TO SOUND AND LAMPS TO FLASH.b.THE 80 CHARACTER LCD DISPLAY SHALL INDICATE ALL INFORMATION ASSOCIATED WITH THE FIRE ALARMCONDITION, INCLUDING THE TYPE OF ALARM POINT AND ITS LOCATION WITHIN THE PROTECTEDPREMISES.c.INITIATE OFF-SITE ALARM NOTIFICATION.d.RELEASE MAGNETIC DOOR HOLDERS.e.INITIATE SHUT DOWN OF MECHANICAL UNITS WITH AIR FLOW IN EXCESS OF 2000CFM.f.INITIATE CLOSURE OF ALL FIRE/SMOKE DAMPERS.4.WIRING: THE MULTIPLEX BUSS AND DATA COMMUNICATION BUS (OPTIONS BUS) SHALL BE WIRED WITHSTANDARD NEC 760 COMPLIANT WIRING. ALL FACP SCREW TERMINALS SHALL BE CAPABLE OF ACCEPTING 14AWG (1.8 MM) TO 18 AWG (1.2 MM) WIRE. ALL SYSTEM WIRING SHALL BE IN ACCORDANCE WITH THEREQUIREMENTS OF NFPA 70, THE NATIONAL ELECTRICAL CODE (NEC) AND ALSO COMPLY WITH ARTICLE 760OF THE NEC.C.QUALITY ASSURANCE1.REGULATORY REQUIREMENTSa.SYSTEM SHALL MEET APPROVAL OF AUTHORITY HAVING JURISDICTION (AHJ). CHANGES OR ADDITIONSSHALL BE MADE TO THE SYSTEM AS REQUIRED WITHOUT ADDITIONAL COST TO OWNER.b.EQUIPMENT, DEVICES, AND CABLE SHALL BE UL OR FACTORY MUTUAL LISTED FOR USE IN FIRE ALARMSYSTEMS.c.DESIGNER QUALIFICATIONS: NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN ORREGISTERED FIRE PROTECTION ENGINEER, EMPLOYED BY FIRE ALARM CONTROL PANELMANUFACTURER, CONTRACTOR, OR INSTALLER.d.INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM 3 YEARS DOCUMENTED EXPERIENCE INSTALLING FIREALARM SYSTEMS OF THE SPECIFIED TYPE AND PROVIDING CONTRACT MAINTENANCE SERVICE AS AREGULAR PART OF THEIR BUSINESS.1)AUTHORIZED REPRESENTATIVE OF CONTROL UNIT MANUFACTURER; SUBMIT MANUFACTURER'SCERTIFICATION THAT INSTALLER IS AUTHORIZED; INCLUDE NAME AND TITLE OF MANUFACTURER'SREPRESENTATIVE MAKING CERTIFICATION.2)INSTALLER PERSONNEL: FACTORY TRAINED AND CERTIFIED WITH AT LEAST 2 YEARS OFEXPERIENCE INSTALLING FIRE ALARM SYSTEMS.3)SUPERVISOR: NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN; FURNISH NAMEAND ADDRESS.D.FACP COMPONENTS:1.EQUIPMENT AND ACCESSORIES FURNISHED UNDER TERMS OF THIS SPECIFICATION SHALL BE STANDARDPRODUCTS OF SINGLE MANUFACTURER, OR INCLUDE WRITTEN STATEMENT BY CONTROL PANELMANUFACTURER CONFIRMING COMPATIBILITY OF COMPONENTS AND INCLUSION OF THESE COMPONENTSUNDER SYSTEM WARRANTY.2.THE MAIN FACP CENTRAL CONSOLE SHALL CONTAIN A MICROPROCESSOR BASED CENTRAL PROCESSINGUNIT (CPU). THE FACP SHALL COMMUNICATE WITH AND CONTROL THE FOLLOWING TYPES OF EQUIPMENTUSED TO MAKE UP THE SYSTEM: ADDRESSABLE DETECTORS, ADDRESSABLE MODULES, LOCAL AND REMOTEOPERATOR TERMINALS, ANNUNCIATORS, AND OTHER SYSTEM CONTROLLED DEVICES.a.THE MAIN FACP AND CENTRAL CONSOLE SHALL PERFORM THE FOLLOWING FUNCTIONS:b.SUPERVISE AND MONITOR ALL ADDRESSABLE DETECTORS AND MONITOR MODULES CONNECTED TO THESYSTEM FOR NORMAL, TROUBLE AND ALARM CONDITIONS.c.SUPERVISE ALL NOTIFICATION CIRCUITS THROUGHOUT THE FACILITY.d.VISUALLY AND AUDIBLY ANNUNCIATE ANY TROUBLE, SUPERVISORY OR ALARM CONDITION ONOPERATOR'S TERMINAL, PANEL DISPLAY, AND ANNUNCIATORS.3.THE FIRE ALARM CONTROL PANEL SHALL INCLUDE A FULL FEATURED OPERATOR INTERFACE CONTROL ANDANNUNCIATION PANEL WHICH SHALL INCLUDE A BACKLIT LIQUID CRYSTAL DISPLAY, INDIVIDUAL, COLORCODED SYSTEM STATUS LEDS, AND AN ALPHA-NUMERIC KEYPAD FOR FIELD PROGRAMMING AND CONTROLOF THE FIRE ALARM SYSTEM.4.THE SYSTEM SHALL INCLUDE EMERGENCY EVACUATION SIGNAL UTILIZING INTELLIGENCE SUCH THAT LOSSOF OPERATION BY THE MAIN FACP WILL NOT RESULT IN THE LOSS OF EVACUATION SIGNAL THROUGHOUTTHE BALANCE OF THE BUILDING.5.THE MAIN COMMUNICATION BUS (OPTIONS BUS) SHALL BE CAPABLE OF CLASS A OR CLASS B CONFIGURATIONWITH A TOTAL BUS LENGTH OF 5,900 FEET (1,798 M).6.OFF-SITE ALARM NOTIFICATION SYSTEMa.PROVIDE TELEPHONE LINE CONNECTION FROM TELEPHONE TERMINAL BOARD TO FIRE ALARM CONTROLPANEL.b.PROVIDE DIALER DEVICE TO NOTIFY OFF-SITE PERSONNEL OF ALARM OR ABNORMAL CONDITIONS.c.CONNECT TO FIRE ALARM CONTROL PANEL SO SPECIFIED CONDITIONS INITIATE OFF-SITE CALL. USE ONEALARM CODE FOR ALARM AND SECOND CODE FOR SUPERVISORY/TROUBLE ALARM.7.AUDIBLE HORN ALARM ANNUNCIATIONa.PROVIDE SEPARATE AND DISTINCT ALARM SIGNALS FOR ALARM AND TROUBLE CONDITIONS.b.ALARM SIGNAL SHALL ALSO OPERATE STROBE LIGHTS, IF SPECIFIED.c.PROVIDE ALARM SILENCE SWITCHES AT CONTROL PANEL.d.TROUBLE ALARM SHALL BE HORN INTEGRAL TO CONTROL PANEL.e.SUPERVISORY ALARM MAY BE SAME AUDIBLE ALARM AS TROUBLE ALARM, BUT WITH SEPARATE VISUALANNUNCIATION.E.FIELD MOUNTED SYSTEM COMPONENTS1.FIRE ALARM INITIATING DEVICESa.DUCT DETECTOR HOUSING: PROVIDE SMOKE DETECTOR DUCT HOUSING ASSEMBLIES TO MOUNT ANADDRESSABLE DETECTOR ALONG WITH A STANDARD, RELAY OR ISOLATOR DETECTOR MOUNTING BASE.THE HOUSING SHALL ALSO PROTECT THE MEASURING CHAMBER FROM DAMAGE AND INSECTS. THEHOUSING SHALL UTILIZE AN AIR EXHAUST TUBE AND AN AIR SAMPLING INLET TUBE THAT EXTENDS INTOTHE DUCT AIR STREAM UP TO TEN FEET. DRILLING TEMPLATES AND GASKETS TO FACILITATE LOCATINGAND MOUNTING THE HOUSING SHALL ALSO BE PROVIDED. THE HOUSING SHALL BE FINISHED IN BAKEDRED ENAMEL. REMOTE ALARM LED INDICATORS AND REMOTE TEST STATIONS SHALL BE PROVIDED.b.ADDRESSABLE SMOKE DETECTORS1)CEILING MOUNTED, ADDRESSABLE PHOTOELECTRIC2)UL LISTED COMPATIBLE WITH THE FIRE ALARM CONTROL PANEL.3)SHALL HAVE A FLASHING STATUS LED FOR VISUAL SUPERVISION. WHEN THE DETECTOR ISACTUATED, THE FLASHING LED WILL LATCH ON SOLID. THE LED SHALL FLASH AT A 1/SEC RATE IFTHE CHAMBER IS OUT OF CALIBRATION RANGE. THE DETECTOR MAY BE RESET BY ACTUATINGTHE CONTROL PANEL'S RESET SWITCH.c.SMOKE DETECTOR GUARDS1)UNDERWRITERS LABORATORIES TESTED AND LISTED BY FOR USE WITH THE SMOKE DETECTORSTHEY PROTECT.2)GUARD DESIGN SHALL NOT AFFECT THE DETECTOR OPERATING SENSITIVITY AND SHALL NOTREDUCE THE LISTED DETECTOR SPACING.3)CONSTRUCTED OF 16-GAUGE STEEL WITH A BAKED WHITE FINISH TO MATCH THE DETECTORS.4)TAMPERPROOF MOUNTING HARDWARE SHALL BE PROVIDED.d.ADDRESSABLE FIXED TEMPERATURE-ROR HEAT DETECTOR1)ADDRESSABLE COMBINATION FIXED TEMPERATURE / RATE-OF-RISE2)NOMINAL FIXED TEMPERATURE ALARM POINT RATING OF 135°F (57°C) AND A RATE OF RISE ALARMPOINT OF 15°F(9°C) PER MINUTE.3)RATED FOR CEILING INSTALLATION AT A MINIMUM OF 70 FT (21.3M) CENTERS AND BE SUITABLEFOR WALL MOUNT APPLICATIONS.e.DETECTOR BASES: STANDARD DETECTOR MOUNTING BASES SUITABLE FOR MOUNTING ON EITHERNORTH AMERICAN 1-GANG, 3½ OR 4 INCH OCTAGON BOX AND 4 INCH SQUARE BOX, OR EUROPEAN BESAOR 1-GANG BOX. THE BASE SHALL, CONTAIN NO ELECTRONICS AND SUPPORT ALL SERIES DETECTORTYPES.f.ADDRESSABLE MANUAL STATION1)ADDRESSABLE DOUBLE ACTION, SINGLE STAGE2)POLYCARBONATE CONSTRUCTION WITH INTERNAL TOGGLE SWITCH.3)FINISHED IN RED WITH SILVER "PULL IN CASE OF FIRE" LETTERING4)SUITABLE FOR MOUNTING ON NORTH AMERICAN 2 ½ (64MM) DEEP 1-GANG BOXES AND 1 ½ (38MM)DEEP 4 SQUARE BOXES WITH 1-GANG COVERS.2.FIRE ALARM ACTUATING DEVICESa.DOOR HOLDING DEVICES: DOOR RELEASE UNITS SHALL BE ELECTRICALLY OPERATED MAGNETICDEVICES WHICH HOLD DOORS OPEN UNTIL RELEASED BY THE MAIN CONTROL UNIT. PROVIDE DOORPLATES AND COORDINATE WITH THE GENERAL CONTRACTOR TO INSURE THAT THE PLATES AREPROPERLY MOUNTED ON THE DOORS.b.NOTIFICATION APPLIANCES1)LOW PROFILE HORN-STROBESa)AUDIBLE OUTPUT OF 92 DBA AT 10 FT. WHEN MEASURED IN REVERBERATION ROOM PERUL-464.b)INTEGRALLY MOUNTED FLASHING LIGHT UNIT WITH BLOCK LETTERS 'FIRE'. MULTI-CANDELAWITH FIELD-SELECTABLE SETTINGS OF 15CD, 30CD, 60CD, 75CD & 110CD, AND FLASH RATEBETWEEN ONE AND THREE HERTZ. ALL UNITS SHALL FLASH IN SYNCHRONIZATION WITHEACH OTHER.c)THE HORN SHALL HAVE A SELECTABLE STEADY OR SYNCHRONIZED TEMPORAL OUTPUT.d)IN AND OUT SCREW TERMINALS SHALL BE PROVIDED FOR WIRING.e)LOW PROFILE HORN/STROBES SHALL MOUNT IN A NORTH AMERICAN 1-GANG BOX.2)LOW PROFILE STROBESa)PROVIDE LOW PROFILE WALL MOUNTED STROBES AT THE LOCATIONS SHOWN ON THEDRAWINGS. IN AND OUT SCREW TERMINALS SHALL BE PROVIDED FOR WIRING. STROBESSHALL PROVIDE SYNCHRONIZED FLASH OUTPUTS. STROBE OUTPUT SHALL BE DETERMINEDAS REQUIRED BY ITS SPECIFIC LOCATION AND APPLICATION FROM A FAMILY OF 15CD, 30CD,60CD, 75CD, OR 110CD DEVICES. LOW PROFILE STROBES SHALL MOUNT IN A NORTHAMERICAN 1-GANG BOX.3.INITIATION & CONTROL MODULESa.RELAY MODULE1)PROVIDE ADDRESSABLE CONTROL RELAY CIRCUIT MODULES AS REQUIRED. THE MODULE SHALLPROVIDE ONE (1) FORM C DRY RELAY CONTACTS RATED AT 24VDC @ 2 AMPS (PILOT DUTY) TOCONTROL EXTERNAL APPLIANCES OR EQUIPMENT. THE POSITION OF THE RELAY CONTACT SHALLBE CONFIRMED BY THE SYSTEM FIRMWARE.F.BATTERIES1.SHALL BE 12 VOLT, GELL-CELL TYPE.2.BATTERY SHALL HAVE SUFFICIENT CAPACITY TO POWER THE FIRE ALARM SYSTEM FOR NOT LESS THANTWENTY-FOUR HOURS PLUS 5 MINUTES OF ALARM UPON A NORMAL AC POWER FAILURE.3.THE BATTERIES ARE TO BE COMPLETELY MAINTENANCE FREE. NO LIQUIDS ARE REQUIRED. FLUID LEVELCHECKS REFILLING, SPILLS AND LEAKAGE SHALL NOT BE REQUIRED.G.INSTALLATION1.INSTALL FIRE ALARM AND DETECTION SYSTEMS AS INDICATED, IN ACCORDANCE WITH EQUIPMENTMANUFACTURER'S WRITTEN INSTRUCTIONS, AND COMPLYING WITH APPLICABLE PORTIONS OF NEC, NFPAAND NECA'S "STANDARD OF INSTALLATION".2.INSTALL WIRING, RACEWAYS, CONDUCTORS, ELECTRICAL BOXES AND FITTINGS IN ACCORDANCE WITHCONDUIT, WIRE AND CABLE, AND BOXES AND PLATES SECTION OF THIS SPECIFICATION.3.LABEL PULL AND JUNCTION BOXES "FIRE ALARM" WITH RED INDELIBLE INK.4.LOOP WIRES THROUGH EACH DEVICE ON ZONE FOR PROPER SUPERVISION. TEE-TAPS NOT PERMITTED.5.PROVIDE DUST PROTECTION FOR INSTALLED SMOKE DETECTORS UNTIL FINISH WORK IS COMPLETED ANDBUILDING IS READY FOR OCCUPANCY.6.PROTECT CONDUCTORS FROM CUTS, ABRASION AND OTHER DAMAGE DURING CONSTRUCTION.7.MINIMUM CONDUCTOR SIZE SHALL BE 14 AWG UNLESS OTHERWISE SPECIFIED.8.DO NOT INSTALL CEILING MOUNTED DETECTORS WITHIN 3 FEET OF AIR DISCHARGE GRILLS. COORDINATEWITH OTHER TRADES AS REQUIRED.9.POST COPY OF WIRE IDENTIFICATION LIST INSIDE FIRE ALARM PANEL DOOR OR OTHER AREA ACCESSIBLE TOFIRE ALARM SERVICE PERSONNEL.10.PROVIDE DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS WITH AIR FLOW IN EXCESS OF 2000 CFMAND TIE INTO FIRE ALARM CONTROL PANEL. PROVIDE FAN SHUT DOWN CIRCUIT AND ASSOCIATED CONTROLEQUIPMENT FOR ALL REQUIRED MECHANICAL UNITS.11.INSTALL CONDUCTORS AND MAKE CONNECTIONS TO ALL, WATER FLOW SWITCHES, VALVE TAMPERSWITCHES.H.FIELD QUALITY CONTROL1.TEST & INSPECTIONa.ALL INTELLIGENT ADDRESSABLE DEVICES SHALL BE TESTED FOR CURRENT ADDRESS AND USERDEFINED MESSAGE.b.ALL WIRING SHALL BE TESTED FOR CONTINUITY, SHORTS, AND GROUNDS BEFORE THE SYSTEM ISACTIVATED.c.ALL TEST EQUIPMENT, INSTRUMENTS, TOOLS AND LABOR REQUIRED TO CONDUCT THE TESTS SHALL BEMADE AVAILABLE BY THE INSTALLING CONTRACTOR.d.THE SYSTEM INCLUDING ALL ITS SEQUENCE OF OPERATIONS SHALL BE DEMONSTRATED TO THE OWNER,HIS REPRESENTATIVE, AND THE LOCAL FIRE INSPECTOR. IN THE EVENT THE SYSTEM DOES NOT OPERATEPROPERLY, THE TEST SHALL BE TERMINATED. CORRECTIONS SHALL BE MADE AND THE TESTINGPROCEDURE SHALL BE REPEATED UNTIL IT IS ACCEPTABLE TO THE OWNER, HIS REPRESENTATIVES ANDTHE FIRE INSPECTOR.e.ALL FIRE ALARM TESTING SHALL BE IN ACCORDANCE WITH NATIONAL FIRE ALARM CODE, NFPA 72.I.MANUFACTURER'S FIELD SERVICE1.INSTRUCT OWNER'S REPRESENTATIVE IN PROPER OPERATION AND MAINTENANCE PROCEDURES.2.PROVIDE A MINIMUM OF 4 HOURS TRAINING.TELEPHONE/DATA SYSTEMSA.SUMMARY1.INCLUDES BUT NOT LIMITED TOa.FURNISH AND INSTALL BUILDING TELEPHONE AND COMPUTER NETWORK RACEWAY AND CABLE SYSTEMAS DESCRIBED IN CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, RACEWAY, OUTLETS,MODULAR JACKS, DEVICE PLATES, CABLES, PUNCH DOWN BLOCKS, BACKBOARDS, CABINETS, PATCHPANELS, GROUNDING AND OTHER MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETE SYSTEM.b.FURNISH AND INSTALL MAIN SERVICE RACEWAY AS DESCRIBED IN CONTRACT DOCUMENTS AND TOCOMPLY WITH TELEPHONE COMPANY REQUIREMENTS.B.COMPONENTS1.TELEPHONE OUTLET BOX SHALL BE SINGLE DEVICE BOX.2.BUILDING TELEPHONE AND COMPUTER NETWORK SYSTEM CABLEa.23 GAUGE, SOLID TINNED COPPER, FOUR TWISTED PAIRS. CATEGORY 6b.USE PLENUM-RATED CABLE IN CEILINGS AND AREAS USED FOR PLENUM AIR RETURN3.TELEPHONE TERMINATION BLOCKSa.UL VERIFIED CATEGORY 6.b.110 TERMINATION WITH TIN LEAD PLATED IDC4.NETWORK PATCH PANELSa.UL VERIFIED CATEGORY 6b.110 TERMINATION WITH TIN LEAD PLATED IDCc.19" RACK MOUNT WITH BACKBOARD MOUNTING FRAME.d.48 PORTS5.TELEPHONE/NETWORK JACKSa.WALL JACKS1)CAT6 - HUBBELL HXJ6 OR ALTERNATE MANUFACTURER WITH EQUIVALENT PERFORMANCESTANDARD.b.PLATES1)HUBBELL - IFP SERIES (PORT QUANTITY AS REQUIRED, COLOR BY ARCHITECT)6.BACKBOARDS: INTERIOR GRADE PLYWOOD WITHOUT VOIDS, 34 INCH THICK; UL-LABELED FIRE RETARDANT.a.SIZE: 48 INCHES WIDE 96 INCHES HIGH.b.DO NOT PAINT OVER UL LABEL.c.PROVIDE ONE 48" MULTI-OUTLET POWER STRIP WITH INTEGRAL SURGE PROTECTION AND OUTLETS AT 6"O.C. (MINIMUM 7 OUTLETS) MOUNTED AT CENTER OF TERMINAL BOARD.7.EQUIPMENT RACKS AND CABINETS: CEA-310 STANDARD 19 INCH WIDE COMPONENT RACKS.a.FLOOR MOUNTED RACKS: 16 GAGE STEEL CONSTRUCTION WITH CORROSION RESISTANT FINISH;VERTICAL AND HORIZONTAL CABLE MANAGEMENT CHANNELS, TOP AND BOTTOM CABLE TROUGHS, ANDGROUNDING LUG.8.CONNECTOR BLOCKS FOR CATEGORY 6 AND UP CABLING: TYPE 110 INSULATION DISPLACEMENTCONNECTORS; CAPACITY SUFFICIENT FOR CABLES TO BE TERMINATED PLUS 25 PERCENT SPARE.9.PATCH PANELS FOR COPPER CABLING: SIZED TO FIT EIA STANDARD 19 INCH WIDE EQUIPMENT RACKS; 0.09INCH THICK ALUMINUM; CABLING TERMINATED ON TYPE 110 INSULATION DISPLACEMENT CONNECTORS;PRINTED CIRCUIT BOARD INTERFACE.a.JACKS: NON-KEYED RJ-45, SUITABLE FOR AND COMPLYING WITH SAME STANDARDS CABLE TO BETERMINATED; MAXIMUM 48 PORTS PER STANDARD WIDTH PANEL.b.CAPACITY: PROVIDE PORTS SUFFICIENT FOR CABLES TO BE TERMINATED PLUS 25 PERCENT SPARE PLUSMOUNTING SPACE FOR ALL ACTIVE COMPONENTS/EQUIPMENT REQUIRED TO CROSS-CONNECT TOANY/ALL MODULAR JACK PORTS ON THE PATCH PANELS.c.LABELS: FACTORY INSTALLED LAMINATED PLASTIC NAMEPLATES ABOVE EACH PORT, NUMBEREDCONSECUTIVELY; COMPLY WITH TIA/EIA-606 USING ENCODED IDENTIFIERS.d.PROVIDE INCOMING CABLE STRAIN RELIEF AND ROUTING GUIDES ON BACK OF PANEL.e.PATCH CORDS: PROVIDE ONE PATCH CORD FOR EACH PAIR OF PATCH PANEL PORTS.10.CABLE MANAGEMENTa.EQUIP EACH RACK OR CABINET WITH VERTICAL CABLE SECTION.b.EQUIP EACH RACK OR CABINET WITH HORIZONTAL CABLE MANAGERS ABOVE AND BELOW EACH PATCHSECTION.1)7 RINGS2)6 PASS-THROUGH HOLES3)HINGED FRONT COVERc.USE VELCRO CABLE WRAPS ON ALL CABLE - TIE WRAPS ARE NOT ACCEPTABLE.C.INSTALLATION1.RUN 1" CONDUIT TO ACCESSIBLE CEILING SPACE FROM EACH OUTLET. INSTALL CABLE FROM TERMINALBOARD TO EACH TELEPHONE/NETWORK OUTLET.2.TERMINATE CABLES AT EACH OUTLET WITH SPECIFIED MODULAR JACK ASSEMBLY.3.TERMINATE CABLES ON PUNCH DOWN BLOCKS OR PATCH PANELS AT TERMINAL BOARD.4.PROVIDE TYPED LABELS AT ALL JACKS CORRESPONDING TO TYPED NUMBERING SYSTEM AT PATCH PANELOR TERMINAL STRIP.D.QUALITY ASSURANCE1.COMPLY WITH APPLICABLE PORTIONS OF NEC ANSI/EIA/TIA 568 AS TO TYPE PRODUCTS USED ANDINSTALLATION OF COMPONENTS. PROVIDE PRODUCTS AND MATERIALS WHICH HAVE BEEN UL-LISTED ANDLABELED.LOW-VOLTAGE TRANSFORMERSA.GENERAL1.REFERENCE STANDARDSa.10 CFR 431, SUBPART K - ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIALEQUIPMENT - DISTRIBUTION TRANSFORMERS; CURRENT EDITION.b.IEEE C57.94 - RECOMMENDED PRACTICE FOR INSTALLATION, APPLICATION, OPERATION, ANDMAINTENANCE OF DRY-TYPE GENERAL PURPOSE DISTRIBUTION AND POWER TRANSFORMERS; INSTITUTEOF ELECTRICAL AND ELECTRONIC ENGINEERS; 1982 (R2006).c.IEEE C57.96 - GUIDE FOR LOADING DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS; INSTITUTE OFELECTRICAL AND ELECTRONIC ENGINEERS; 1999 (R2004).d.NECA 1 - STANDARD FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION; NATIONAL ELECTRICALCONTRACTORS ASSOCIATION; 2010.e.NECA 409 - STANDARD FOR INSTALLING AND MAINTAINING DRY-TYPE TRANSFORMERS; NATIONALELECTRICAL CONTRACTORS ASSOCIATION; 2009.f.NEMA ST 20 - DRY-TYPE TRANSFORMERS FOR GENERAL APPLICATIONS; NATIONAL ELECTRICALMANUFACTURERS ASSOCIATION; 2014.g.NEMA 250 - ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM); NATIONAL ELECTRICALMANUFACTURERS ASSOCIATION; 2014h.NFPA 70 - NATIONAL ELECTRICAL CODE; NATIONAL FIRE PROTECTION ASSOCIATION; MOST RECENTEDITION ADOPTED BY AUTHORITY HAVING JURISDICTION, INCLUDING ALL APPLICABLE AMENDMENTS ANDSUPPLEMENTS.i.UL 506 - STANDARD FOR SPECIALTY TRANSFORMERS; CURRENT EDITION, INCLUDING ALL REVISIONS.j.UL 1561 - STANDARD FOR DRY-TYPE GENERAL PURPOSE AND POWER TRANSFORMERS; CURRENTEDITION, INCLUDING ALL REVISIONS.B.PRODUCTS1.TRANSFORMERS - GENERAL REQUIREMENTSa.DESCRIPTION: FACTORY-ASSEMBLED, DRY TYPE TRANSFORMERS FOR 60 HZ OPERATION DESIGNED ANDMANUFACTURED IN ACCORDANCE WITH NEMA ST 20 AND LISTED, CLASSIFIED, AND LABELED AS SUITABLEFOR THE PURPOSE INTENDED.b.UNLESS NOTED OTHERWISE, TRANSFORMER RATINGS INDICATED ARE FOR CONTINUOUS LOADINGACCORDING TO IEEE C57.96 UNDER THE FOLLOWING SERVICE CONDITIONS:1)ALTITUDE: LESS THAN 3,300 FEET (1,000 M).2)AMBIENT TEMPERATURE:a)GREATER THAN 10 KVA: NOT EXCEEDING 104 DEGREES F (40 DEGREES C).b)LESS THAN 10 KVA: NOT EXCEEDING 77 DEGREES F (25 DEGREES C).c.CORE: HIGH GRADE, NON-AGING SILICON STEEL WITH HIGH MAGNETIC PERMEABILITY AND LOWHYSTERESIS AND EDDY CURRENT LOSSES. KEEP MAGNETIC FLUX DENSITIES SUBSTANTIALLY BELOWSATURATION POINT, EVEN AT 10 PERCENT PRIMARY OVERVOLTAGE. TIGHTLY CLAMP CORE LAMINATIONSTO PREVENT PLATE MOVEMENT AND MAINTAIN CONSISTENT PRESSURE THROUGHOUT CORE LENGTH.d.IMPREGNATE CORE AND COIL ASSEMBLY WITH NON-HYDROSCOPIC THERMO-SETTING VARNISH TOEFFECTIVELY SEAL OUT MOISTURE AND OTHER CONTAMINANTS.e.BASIC IMPULSE LEVEL: 10 KV.f.GROUND CORE AND COIL ASSEMBLY TO ENCLOSURE BY MEANS OF A VISIBLE FLEXIBLE COPPERGROUNDING STRAP.g.ISOLATE CORE AND COIL FROM ENCLOSURE USING VIBRATION-ABSORBING MOUNTS.h.NAMEPLATE: INCLUDE TRANSFORMER CONNECTION DATA, RATINGS, WIRING DIAGRAMS, AND OVERLOADCAPACITY BASED ON RATED WINDING TEMPERATURE RISE.2.GENERAL PURPOSE TRANSFORMERSa.DESCRIPTION: SELF-COOLED, TWO WINDING TRANSFORMERS LISTED AND LABELED AS COMPLYING WITHUL 506 OR UL 1561; RATINGS AS INDICATED ON THE DRAWINGS.b.INSULATION SYSTEM AND ALLOWABLE AVERAGE WINDING TEMPERATURE RISE:1)LESS THAN 15 KVA: CLASS 180 DEGREES C INSULATION SYSTEM WITH 115 DEGREES C AVERAGEWINDING TEMPERATURE RISE.2)15 KVA AND LARGER: CLASS 220 DEGREES C INSULATION SYSTEM WITH 150 DEGREES C AVERAGEWINDING TEMPERATURE RISE.c.COIL CONDUCTORS: CONTINUOUS ALUMINUM WINDINGS WITH TERMINATIONS BRAZED OR WELDED.d.WINDING TAPS:1)LESS THAN 3 KVA: NONE.2)3 KVA THROUGH 15 KVA: TWO 5 PERCENT FULL CAPACITY PRIMARY TAPS BELOW RATED VOLTAGE.3)15 KVA THROUGH 300 KVA: TWO 2.5 PERCENT FULL CAPACITY PRIMARY TAPS ABOVE AND FOUR 2.5PERCENT FULL CAPACITY PRIMARY TAPS BELOW RATED VOLTAGE.4)500 KVA AND LARGER: TWO 2.5 PERCENT FULL CAPACITY PRIMARY TAPS ABOVE AND TWO 2.5PERCENT FULL CAPACITY PRIMARY TAPS BELOW RATED VOLTAGE.e.ENERGY EFFICIENCY: COMPLY WITH 10 CFR 431, SUBPART K.f.SOUND LEVELS: STANDARD SOUND LEVELS COMPLYING WITH NEMA ST 20.g.MOUNTING PROVISIONS:1)LESS THAN 15 KVA: SUITABLE FOR WALL MOUNTING.2)15 KVA THROUGH 75 KVA: SUITABLE FOR WALL, FLOOR, OR TRAPEZE MOUNTING.3)LARGER THAN 75 KVA: SUITABLE FOR FLOOR MOUNTING.h.TRANSFORMER ENCLOSURE: COMPLY WITH NEMA ST 20.1)ENVIRONMENT TYPE PER NEMA 250: UNLESS OTHERWISE INDICATED, AS SPECIFIED FOR THEFOLLOWING INSTALLATION LOCATIONS:2)CONSTRUCTION: STEEL.a)LESS THAN 15 KVA: TOTALLY ENCLOSED, NON-VENTILATED.b)15 KVA AND LARGER: VENTILATED.3)FINISH: MANUFACTURER'S STANDARD GREY, SUITABLE FOR OUTDOOR INSTALLATIONS.4)PROVIDE LIFTING EYES OR BRACKETS.i.ACCESSORIES:1)MOUNTING BRACKETS: PROVIDE MANUFACTURER'S STANDARD BRACKETS.2)WEATHERSHIELD KITS: PROVIDE FOR VENTILATED TRANSFORMERS INSTALLED OUTDOORS TOPROVIDE A LISTED NEMA 250, TYPE 3R ASSEMBLY.3)LUG KITS: SIZED AS REQUIRED FOR TERMINATION OF CONDUCTORS AS INDICATED ON THEDRAWINGS.C.EXECUTION1.INSTALLATIONa.PERFORM WORK IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH NECA 1.b.INSTALL TRANSFORMERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.c.INSTALL TRANSFORMERS IN ACCORDANCE WITH NECA 409 AND IEEE C57.94.d.USE FLEXIBLE CONDUIT, UNDER THE PROVISIONS OF THE CONDUIT SECTION OF THIS SPECIFICATION, 2FEET (600 MM) MINIMUM LENGTH, FOR CONNECTIONS TO TRANSFORMER CASE. MAKE CONDUITCONNECTIONS TO SIDE PANEL OF ENCLOSURE.e.ARRANGE EQUIPMENT TO PROVIDE MINIMUM CLEARANCES AS SPECIFIED ON TRANSFORMER NAMEPLATEAND IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NFPA 70.f.MOUNT WALL-MOUNTED TRANSFORMERS USING INTEGRAL FLANGES OR ACCESSORY BRACKETSFURNISHED BY THE MANUFACTURER.g.MOUNT FLOOR-MOUNTED TRANSFORMERS ON PROPERLY SIZED 3 INCH (80 MM) HIGH CONCRETE PADCONSTRUCTED IN ACCORDANCE WITH MANUFACTURER SPECIFICATION.h.MOUNT FLOOR-MOUNTED, TRAPEZE-MOUNTED, WALL-MOUNTED, AND CEILING-MOUNTEDTRANSFORMERS USING VIBRATION ISOLATORS SUITABLE FOR ISOLATING THE TRANSFORMER NOISEFROM THE BUILDING STRUCTURE.i.MOUNT TRAPEZE-MOUNTED TRANSFORMERS AS INDICATED.j.PROVIDE SEISMIC RESTRAINTS.k.PROVIDE GROUNDING AND BONDING IN ACCORDANCE WITH THE GROUNDING SECTION OF THISSPECIFICATION.l.REMOVE SHIPPING BRACES AND ADJUST BOLTS THAT ATTACH THE CORE AND COIL MOUNTING BRACKETTO THE ENCLOSURE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS IN ORDER TO REDUCEAUDIBLE NOISE TRANSMISSION.m.WHERE NOT FACTORY-INSTALLED, INSTALL LUGS SIZED AS REQUIRED FOR TERMINATION OFCONDUCTORS AS SHOWN ON THE DRAWINGS.n.WHERE FURNISHED AS A SEPARATE ACCESSORY, INSTALL TRANSFORMER WEATHERSHIELD PERMANUFACTURER'S INSTRUCTIONS.2.ADJUSTINGa.MEASURE PRIMARY AND SECONDARY VOLTAGES AND MAKE APPROPRIATE TAP ADJUSTMENTS.b.ADJUST TIGHTNESS OF MECHANICAL AND ELECTRICAL CONNECTIONS TO MANUFACTURER'SRECOMMENDED TORQUE SETTINGS.3.CLEANINGa.CLEAN DIRT AND DEBRIS FROM TRANSFORMER COMPONENTS ACCORDING TO MANUFACTURER'SINSTRUCTIONS.b.REPAIR SCRATCHED OR MARRED EXTERIOR SURFACES TO MATCH ORIGINAL FACTORY FINISH.