Loading...
HomeMy WebLinkAboutRESCHECK - 05-00330 - 394 & 398 Eagle Summit St - New TwinhomeREScheck Compliance Certificate 2003 IECC REScheckSoAmm Version 3.6 Release 1 ^ Data Gloaame: Unlillcd.n k 1 ' PROJECT TITLE: Iowa house lot lS side garage CITY: Idaho Falls STATE: Idaho HDD: 7918 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.22 DATE: 09/05 DATE OF PLANS: aug 30,05 PROJECT DESCRIPTION: tram house side garage ' DESIGNER/CONTRACTOR: Sainsbury coma. COMPLIANCE: Passes Maximum UA = 610 Your Homc UA = 562 7.9% Better Than Code (UA) 05 r`, Permit Number Chocked By/D.I. SEP szoo5 D By �<< �laLAirs �, UPS1V �.G �a Gross Glazing ArcCavity Cont. or Door �a�o�r��� Nri-w R-Salm£ B:WI, SL:FaM SIA Ceiling 1: Flat Ceiling or Scissor Trus 3580 38.0 0.0 107 Walll:WoodFramo,16"oc. Z777-6 W 24161 22.0 0.0 101 Window l: Vinyl Fra—:Double Pane -11, -E 452 0.340 154 Door 1: Solid 2'" (14o�.pZ dr 76 0.350 27 Door Z Glass 80 0.350 28 Basement Wall l: Solid Concrete or Masonry il,f.ti 2416? 110 0.0 145 Wall height: 7.8' Depth below grade: 7.4' Insulation depth: 7.8' Furnace 2: Forced Her Air, 92 AFIJE COMPLIANCE STATEMENT: Ile proposed building design described here is consistent with the building plans, specifications, and other calculations submitted wild the permit application. The proposed building has been designed to meet the 2003 BICC requirements in REScheekVersion 3.6 Release l (formerly MECchecll and to comply with We ry requirements listed in the RESchecklnspection Checkliv_ Builder/Designer C:�UI �o...� Date O o RESclreck Inspection Checklist 2003 IE REScheckSonwam Version 3.6 Release 1 DATE: 09/06/05 PROJECT TITLE: Iowa boast lot 18 side gmagc Bldg. I Dept.I Use I jCeilings: f I I 1. Ceiling l: Flat Ceiling or Scissor Truss,R-38.0 cavity insulation I Co.—.: I ( Above -Grad. Walls 1 1 I 1. Wall 1: Wood Frame, 16- o.c., R-22.0 cavity insulation I Comments: jBasement walls: I ] I 1. Basement Wall 1: Solid Concrete or Masonry, 7.8' htf7.4' bg/7.8' irmd, I R -I 1.0 cavity insulation I CO.—.": I Windows. I L Window 1: Vinyl Frarnc:Doublc Pane with law -E, U -factor. 0.340 I For windows without labeled 1.1 -factors, describe fcatunx: 8 Pana_ Frame Type Thcm al Bnak7l 1 Yrs l ]NO Comcast: Duors: 1. Door 1: Solid, U -factor. 0.350 Comments: 2. Door 2: Glass, U -factor 0.350 Comments: Heating and Cording Equipmrnt: 1. Furnace 2: Forced Hot Air, 92 AFUE or higher Make and Model Number I AirL—kaga ( hams, pmenmi"s and all older such,pcom s in the building mrclope that are ware,fair I leakage must be sealed. Recessed lights most be 1) Type IC rated, or 2) installed inside an appropriate air -light assembly with a 0.5' clearance from combusn3le materials. If non -IC rated, the fixture must be waulled with a 3- cl amnce from insulation. Skylights Minimum iaadation requirement for skylight shahs equal to or greater than 12 inches is R-19. Vapor Reta di-- Requlred on the warm -in -winter side of all non -vented fmmed ceilings, walls, and Boors. Materials Identification: Materials and equipment must bei stalled in aocordame with the manufactumer insulation instructions, Materials and equipment must be idenwed so that compliance an be determined. Manufacaurer manals for all installed heating and cooling equipment and service water hating equipment must be provided. Insulation R -values, glazing 1.1 -factors, and hating equipment efficiency mon be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in amanditioned attic or outride the building men be insulated to R-11. Return duds in unconditioned attics or outside the building must be insulated to R-6 Supply ducts in uncerditioned spaces must be insulated to RReturn. Return duels in unanditiom-0 spaces (except basenrems) mass be insulated to R-2. Where exterior walls are used as plenums, the wall must be insulated to R-11. Insulation is act required on return ducts in basemen. Dart Construction: Dun connections to flanges ofair distribution system equipment mon be sealed and mahaniaBy, fastened All joints, scams, and connections most be securely fastened with welds, gaskets, nt ties (adhesives), mastic-pluscmbedded-fabric, or tapes Tapes and muGa mon be rated UL 181A or UL 181 B. F=eption: Continuously welded and lodng4ype longitudiraljoints and scours on duce operating .1 1- than 2 in, w.g. (500 Pa). The BVAC system morn provide a tans for balancing air and water systems. Tempentam Commit: Thermostats are regwml for coch separate HVAC system. A manual ar aulomatic ruins to partially restrict or shot off the heating and/or oneling input to each zone or Boor shall be provided. Service Water Hearing: Water heaters with venial pipe risers must have a hat Trap on both the inlet and wild lades the water hater has an integral bat Imp or is pan of a circulating system C I Insulate cimdating hot water pipes to the levels in Table 1 Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools mut have an onto f heater switch and require a cover unless over 20% of the heating energy is from nondepletable sources. Pool pumps require a time clock I Heating and Cooling Piping lnmladov: HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to Ore levels in Table 2. / Table l: Minimum lsu/arion ThicA-for C-faling HM Wafer Fpes tnmlalion Thi lummin lodo byP -S' Heated Water Nan-Citrn Cireutmire Mans and Ron w Temoemmn: (Fl 11n to 1" In l.5" to 2 0" 0- 2 170 -ISO 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum lnsularian Thicknessfor HYAc/hpes Fluid Temp. Insolation Piolna Svstem T- Range (F 7" Rnno Thickness k l" and t "n Inches by P'pe rc 125- to Sizes 2" 2 5"u, 4_ Heating Systems Low Prc m eFempemture 201-250 1.0 1.5 1.5 2.0 Law Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (Cor feed water) Any to 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-550.5 0.5 0.75 1.0 and Brine Bel -40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Permit Number Mcheck Compliance Certificate Checked By/Date 2003 IECC REScheckSo&ware Version 3.6 Release Is Data filename: C:\Program Files\Check\REScheck\Basic.rck CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.15 DATE: 09/14/05 COMPLIANCE: Passes Maximum UA = 712 Your Home UA = 594 16.6% Better Than Code (UA) Gross Glazing Area or Cavity Cont, or Door PeLmi1€I R -Valve R -Value U -Factor SIA Ceiling 1: Flat Ceiling or Scissor Truss 3580 38.0 0.0 107 Wall 1: Wood Frame, 16"o.c. 3582 22.0 0.0 170 Window 1: Vinyl Frame:Double Pane with Low -E 392 0.350 137 Door 1: Solid 76 0.350 27 Door 2: Glass 80 0.350 28 Basement Wall 1: Solid Concrete or Masonry 1664 11.0 0.0 100 Wall height: 8.0' Depth below grade 7.0' Insulation depth: 8.0' Window 2: Vinyl Frame:Double Pane with Low -E 72 0.350 25 Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release Is (itnnerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Date