HomeMy WebLinkAboutRESCHECK - 05-00330 - 394 & 398 Eagle Summit St - New TwinhomeREScheck Compliance Certificate
2003 IECC
REScheckSoAmm Version 3.6 Release 1
^ Data Gloaame: Unlillcd.n k
1 ' PROJECT TITLE: Iowa house lot lS side garage
CITY: Idaho Falls
STATE: Idaho
HDD: 7918
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.22
DATE: 09/05
DATE OF PLANS: aug 30,05
PROJECT DESCRIPTION:
tram house side garage
' DESIGNER/CONTRACTOR:
Sainsbury coma.
COMPLIANCE: Passes
Maximum UA = 610
Your Homc UA = 562
7.9% Better Than Code (UA)
05
r`,
Permit Number
Chocked By/D.I.
SEP szoo5 D
By
�<< �laLAirs
�,
UPS1V �.G
�a
Gross Glazing
ArcCavity Cont. or Door
�a�o�r���
Nri-w R-Salm£ B:WI, SL:FaM
SIA
Ceiling 1: Flat Ceiling or Scissor Trus
3580 38.0 0.0
107
Walll:WoodFramo,16"oc. Z777-6 W
24161 22.0 0.0
101
Window l: Vinyl Fra—:Double Pane -11, -E
452 0.340
154
Door 1: Solid 2'" (14o�.pZ dr
76 0.350
27
Door Z Glass
80 0.350
28
Basement Wall l: Solid Concrete or Masonry il,f.ti
2416? 110 0.0
145
Wall height: 7.8'
Depth below grade: 7.4'
Insulation depth: 7.8'
Furnace 2: Forced Her Air, 92 AFIJE
COMPLIANCE STATEMENT: Ile proposed building design described here is consistent with the building plans, specifications, and other calculations submitted
wild the permit application. The proposed building has been
designed to meet the 2003 BICC requirements in REScheekVersion 3.6 Release l (formerly MECchecll
and to comply with We ry requirements listed in the
RESchecklnspection Checkliv_
Builder/Designer C:�UI �o...�
Date O o
RESclreck Inspection Checklist
2003
IE
REScheckSonwam Version 3.6 Release 1
DATE: 09/06/05
PROJECT TITLE: Iowa boast lot 18 side gmagc
Bldg. I
Dept.I
Use I
jCeilings:
f I I 1. Ceiling l: Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
I Co.—.:
I
( Above -Grad. Walls
1 1 I 1. Wall 1: Wood Frame, 16- o.c., R-22.0 cavity insulation
I Comments:
jBasement walls:
I ] I 1. Basement Wall 1: Solid Concrete or Masonry, 7.8' htf7.4' bg/7.8' irmd,
I R -I 1.0 cavity insulation
I CO.—.":
I Windows.
I L Window 1: Vinyl Frarnc:Doublc Pane with law -E, U -factor. 0.340
I For windows without labeled 1.1 -factors, describe fcatunx:
8 Pana_ Frame Type Thcm al Bnak7l 1 Yrs l ]NO
Comcast:
Duors:
1. Door 1: Solid, U -factor. 0.350
Comments:
2. Door 2: Glass, U -factor 0.350
Comments:
Heating and Cording Equipmrnt:
1. Furnace 2: Forced Hot Air, 92 AFUE or higher
Make and Model Number
I AirL—kaga
( hams, pmenmi"s and all older such,pcom s in the building mrclope that are ware,fair
I leakage must be sealed.
Recessed lights most be 1) Type IC rated, or 2) installed inside an appropriate air -light assembly
with a 0.5' clearance from combusn3le materials. If non -IC rated, the fixture must be waulled with a
3- cl amnce from insulation.
Skylights
Minimum iaadation requirement for skylight shahs equal to or greater than 12 inches is R-19.
Vapor Reta di--
Requlred on the warm -in -winter side of all non -vented fmmed ceilings, walls, and Boors.
Materials Identification:
Materials and equipment must bei stalled in aocordame with the manufactumer insulation instructions,
Materials and equipment must be idenwed so that compliance an be determined.
Manufacaurer manals for all installed heating and cooling equipment and service water hating
equipment must be provided.
Insulation R -values, glazing 1.1 -factors, and hating equipment efficiency mon be clearly marked on
the building plans or specifications.
Duct Insulation:
Supply ducts in amanditioned attic or outride the building men be insulated to R-11.
Return duds in unconditioned attics or outside the building must be insulated to R-6
Supply ducts in uncerditioned spaces must be insulated to RReturn.
Return duels in unanditiom-0 spaces (except basenrems) mass be insulated to R-2.
Where exterior walls are used as plenums, the wall must be insulated to R-11.
Insulation is act required on return ducts in basemen.
Dart Construction:
Dun connections to flanges ofair distribution system equipment mon be sealed and mahaniaBy, fastened
All joints, scams, and connections most be securely fastened with welds, gaskets, nt ties (adhesives),
mastic-pluscmbedded-fabric, or tapes Tapes and muGa mon be rated UL 181A or UL 181 B.
F=eption: Continuously welded and lodng4ype longitudiraljoints and scours on duce
operating .1 1- than 2 in, w.g. (500 Pa).
The BVAC system morn provide a tans for balancing air and water systems.
Tempentam Commit:
Thermostats are regwml for coch separate HVAC system. A manual ar aulomatic ruins to
partially restrict or shot off the heating and/or oneling input to each zone or Boor shall be provided.
Service Water Hearing:
Water heaters with venial pipe risers must have a hat Trap on both the inlet and wild lades the
water hater has an integral bat Imp or is pan of a circulating system
C
I Insulate cimdating hot water pipes to the levels in Table 1
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools mut have an onto f heater switch and require a cover unless over 20%
of the heating energy is from nondepletable sources. Pool pumps require a time clock
I
Heating and Cooling Piping lnmladov:
HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to Ore
levels in Table 2.
/ Table l: Minimum lsu/arion ThicA-for C-faling HM Wafer Fpes
tnmlalion Thi lummin
lodo byP -S'
Heated Water Nan-Citrn
Cireutmire Mans and Ron w
Temoemmn: (Fl 11n to 1" In
l.5" to 2 0"
0- 2
170 -ISO 0.5 1.0
1.5
2.0
140-160 0.5 0.5
1.0
1.5
100-130 0.5 0.5
0.5
1.0
Table 2: Minimum lnsularian Thicknessfor HYAc/hpes
Fluid Temp. Insolation
Piolna Svstem T- Range (F 7" Rnno
Thickness
k l" and t
"n Inches by P'pe
rc 125- to
Sizes
2" 2 5"u, 4_
Heating Systems
Low Prc m eFempemture 201-250 1.0
1.5
1.5
2.0
Law Temperature 120-200 0.5
1.0
1.0
1.5
Steam Condensate (Cor feed water) Any to
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant, 40-550.5
0.5
0.75
1.0
and Brine Bel -40 1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Permit Number
Mcheck Compliance Certificate Checked By/Date
2003 IECC
REScheckSo&ware Version 3.6 Release Is
Data filename: C:\Program Files\Check\REScheck\Basic.rck
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.15
DATE: 09/14/05
COMPLIANCE: Passes
Maximum UA = 712
Your Home UA = 594
16.6% Better Than Code (UA)
Gross Glazing
Area or Cavity Cont, or Door
PeLmi1€I R -Valve R -Value U -Factor SIA
Ceiling 1: Flat Ceiling or Scissor Truss 3580 38.0 0.0 107
Wall 1: Wood Frame, 16"o.c. 3582 22.0 0.0 170
Window 1: Vinyl Frame:Double Pane with Low -E 392 0.350 137
Door 1: Solid 76 0.350 27
Door 2: Glass 80 0.350 28
Basement Wall 1: Solid Concrete or Masonry 1664 11.0 0.0 100
Wall height: 8.0'
Depth below grade 7.0'
Insulation depth: 8.0'
Window 2: Vinyl Frame:Double Pane with Low -E 72 0.350 25
Furnace 1: Forced Hot Air, 92 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release Is (itnnerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Date