HomeMy WebLinkAboutRESCHECK - 05-00332 - 594 & 596 Eaglewood Dr - New TwinhomePeron Number
REScheck Compliance Certificate Choked By/Date
2003 IECC
RESeheckSofiware Version 3.6 Release 1
Dam fit--: Umilledrek
PROJECT TITLE: loin house lot 9
CITY: Idaho Falls
STATE: Idaho
HDD: 7918%
O
CONSTRUCTION TYPE: Single Family
s A
WINDOW/ WALL RATIO: 0.20
O
c O
W
DATE: 09/06105
re N
DATE OF PLANS: aug 30,2005
R
PROJECT DESCRIPTION:
town house pith gable roof
a'
DESIGNER/CONTRACTOR:
sainsbury const.
COMPLIANCE: Passes
Maximum UA=715You
_
Home UA = 635
lis%Dater Than Code (UA)
Glass Glazing
Armor Cavity Cont, or Door
AA
Ceiling l: Flat Ceiling or Scissor Trus 3336 38.0 0.0 t00
Wall l: Wood Frame, 16' o.0 2960 22A 0.0 129
Window 1: Vinyl Fnune:Double Pane with Low•E 505 0.340 172
Door 1: Solid 80 0.350 28
Door 2: Glass 80 0.350 28
BaseffiorWall l: Solid Comae or Masonry 2960 ILO 0.0 178
Wall height: 7.8'
Depth below grade: 7.4'
Iosumeon depth: 7.8'
Furnace 2: Forced Hot Air, 92 AFUE
COMPLIANCE STATEMENT: The proposed building design des W here a consistent with the building plans, spcerhcatious, and other calculations submitted
with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheckVersion 3.6 Release I (formerly Iv1ECehec)
and to comply with the mar*tory requireumms listed in the RESchecklnspection Checklist_
Bmlde/Designer ,,UazU 6!az Dam— 44 , ]Nd
1e)
REScheck Inspection Checklist
2003 IECC
REScheckSoRwan; Version 3.6 Release I
DATE: 09/06/05
PROJECT TITLE: town house lot 9
Bldg.
Dept I
Use ]
I
Ceilings:
I I I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R38.0 cavity insulation
I Comments:
I
I Abov"radc Walls:
I 1 I 1. Wall C Wood Frame, 16" o.c., R-22.0 cavity insulation
Comments:
I
Basement Walls:
[ ] I 1. Basement Wall 1: Solid Concrete or Masonry, 7.8' htf7.4' bg/7.8' insul,
I R-11.0 cavity insulation
I Comments:
Windows:
] I I L Window 1: Vinyl Framc:Doublc Panc with Low -E, 13 -factor. 0.340
I For windows without labeled U -factors, describe features:
I N Panes_ Frame Typc Thermal Break? [ I Yes [ ] No
I Comments:
I
Doors:
( ] I 1. Door 1: Solid, U -factor. 0.350
] Comments:
[ ] I 2. Door 2: Glass, U -factor. 0.350
Comments:
I
I Healing and Cooling Equipment:
[ j I 1. Furnace 2: Forced Hot Air, 92 AFUE or higher
I Make and Model Number
I
] Air leakage:
] j I Joints, penetrations, and all other such openings in the building envelope that are sources of air
i leakage must be sealed.
[ ] I
Recessed lights most be I) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -1C rated, the future must be installed with a
3" clearance from insulation.
I
I Skylights:
[ j I Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19.
I
Vapor Retarder.
[ ) I Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors.
I
I Materials Identification:
[ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined-
Manufacturer
eterminedManufacturer manuals for all installed heating and cooling equipment and service water healing
I equipment must be provided
[ ] I Insulation R -values, glazing U -factors, and healing equipment efficiency must be clearly marked on
I the building plans or spccifcations
Duct Insulation:
[ J I Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] I Return ducts in unconditioned attics or outside the building must be insulated to R6.
[ ) I Supply ducts in unconditioned spaces must be insulated to R -I 1.
( ] I Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
[ ] I Where exterior walls are used as plenums, the wall must be insulated to R-11.
] Insulation is not required on return ducts in basements.
I
Duct Construction:
[ J I Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened
I I I All joints, scams, and connections most be scarcely fastened with welds, gaskets, mastics (adhesives),
I mastic-plusembedded-fabric, or (apes. Tapcs and mastics must be rated UL 181A or UL 181 B.
&ceplion: Continuously welded and locking -type longitudinal joints and seams on ducts
I operating at less than 2 in. w.g. (500 Pa).
[ J I The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ J Thermostats arc required for each separate HVAC system. A manual or automatic means to
] partially restrict or shut off the heating and/or cooling input to each zone or Boor shall be provided.
Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a beat lop on both the inlet and ouliel unless the
I water heater has an integral heat lop or is part of a circulating system.
I 1 I Insulate ^""I'ti"g hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated a.:mmi"g pools must have an on/off heater switch and require a cover unless over 20
of the heating energy is from nondepletable sources. Pool pumps require a time clock
I Heating and Cooling Piping Insolation:
I 1 I HVAC piping conveying fluids above 105 °F or chilled fluids below 55 T must be insulated to the
I levels in Table 2.
Table l: Minimum! ulafian Thic)mecsfor Circulating Hof Water Pipes
Inmlaliro Thicknessin Inchesby Pioe Sire
Heated Water NonLinv,line Rnnouts C'
1 Main,
d R
Is
Temncmhrm(B Iln to l" Ito 101_25" 1.5"io20"
170-180 0.5 1.0 1.5
ove""
2.0
140-160 0.5 0.5 1.0
1.5
100-130 0.5 0.5 0.5
1.0
Table 2: Minimum Insulation Thiek-for HVACApes
fluid Temp. 1-1,1
Th' t WOO
M
PIRC Si-
Pioine Svslem Tear R,,ee (Q 2" Rnnom"
1" and Lest
125-1,2' 25" 10 V
Healing Systems
Low Pt-u7 mpemlure 201-250 1.0
1.5
1.5
2.0
Low Temperature120-200 0.5
LO
1.0
1.5
St.. Condensate (for feed water) Any 1.0
1.0
1.5
2.0
Cooling systems
Chilled Water, Refrigerant 40-55 0.5
O.S
0.75
1.0
and Brine Below 40 1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Depattrnent Use Only)