RESIDENTIAL PLAN CHfCKLIST
(2003 International Residential Code)
Building Permit Number:
Project: ,sj�a�,lA;;•� Job Address,7t C04e
zoningy Z, 12Z Number
No/Fin.
Floor Area (sf),,sk
Valuatiom $
finished, unfinished,,
Permit Fee: $
4k 0 0 "dapp =A&
F
Fixtures,
garage
Plan Check Fee., $
The following comments based on the 2003 edition of the Intemational Residential Code should be resoled
before a buildincy permit is issued.. This correction list is not a building permit. The approval of p1w-is and
specifications does not permit the violation of any section ofthe In�emational Residential Code or any federal,
state or local regula#i.
an�
PLAN CHECK
A. Plans
To Scale xLegible
Plot Plan Y IN Flood Plain
Floor / Foundation Flan
S ectzon showing construction details
All Building Elevations
xes ign Criteria (shall be identified on flans as Wind. - SS m.p.h., Snow ;
puss Calculation Sheets &. Z
Floor Joist Details
Mechanical Design.
ZCnf:lrgy Calculations
(8320 & Ch 11)
B. Zoning (check one- in some cases LDR2 and MDR may apply)
LDR LDRI _Lot area — LDR- 12,000 sq. ft. min. (width 8
(width60 ft. min.).(LDRl duplex - 10,000 sq. ft. min.)
S lb. Per sq ft.)
0 ft. min) & LDRI- 8.,,000: sq. ft. min
C, se
Single Family Duplex (LDR1 only - Conditional use
D. Sed Backs (taken from eaves)
ire4rowL set back (32 ft. from curb)
f
emit
Note: 60% min of front yard green
e-e�
Rear set back (LDR 25 ft. & LDR1 20 ft.)
Sides. set backs (6" for every ft.. of building height with LDR - 7.5min.., & LDR1 - 6'min.)
Building -Height (maximum 3 0 ft.)
E. Footings
,Xproper Sipe has per Table 4 3.1,
Rebar (2-#4 continuous)
use 1500Psf unless sail type is known,, Table 4D1.4.1 for soil. bearing)
..�'
Footing Depth (36" below finished grade and I2" below undisturbed soil; 18 to top of slab -- interior)
F. Fyundatian
��Faundatian walls wl rebar (city ordinance)
12" Anchor Bolts with 2" x 2"x 3/16".square washers (incl. interior bear*ng walls) 8403.1.6.1
r
Foundation Drainage (foundations on s/ Sift soil shall be designed per R405)
Damp proofing/Waterproofmg to; finish grade. R406-1 (fnd. extends 6"' min above grade R404,1.6)
"�Crawl space access of 1 8" x 24" min. R408.3 (may differ if meth appliance �s in crawl space MI 305.1.4)
xaw1 Space Ventilation/Insulat*
an = I sf vest per 1 S� �f.("Ith moisture barrier
within 3' of each comerOnsulate walls vent to inside of home} R408-.2
/Grading slope away from house. R4013
G. Fr-ame
/Seismic Hold Downs and Braced Wall Panels (R602.10)
Floors j oists sized as per R502 .3, Wood I- oists sized per nzanut�.
oists Under Load Bearing Partitions shall be doubled. R502.4
Crirders sized per 8502.5 or per manufir. Tables for engineered products
.1 / antileveres (comply with 8502.3.3 or manufr instruction)
1 sf. per 1500 sq. ft.) and
F° Floor Sheathing (3!4" min for joists 24"
oc & 5/8"' for joists 16" oc) 8503.1
-_Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) 8602.3
Headers in.Bearing Wall shad be designed as per Tables 502,5(1&2 R602.7
---------------
Roof Trusses (designed according to R802. 1 [3. 1 } 3 5 Snow and, 90 mph winds (Local. Conditions)
//Rafter and Truss tie -dawns. (R802.10.5)
XAAttic Access 22" x3011 nein, o ezlin 80
H,terior hovering
Masonry and stucco shall have weather resistive barrier over exterior sheathing; R703.2 & 703.9.1
I. I wof Covering and Ventilation
Roof Ventilation as per R806
Asphalt Shingles (slope>2:12) w/ lee protection. (Other type:
to comply w/ R905.�
I F"Irewalls
Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2
,Door from Garage to douse (13/8"
solid wood or steel door., or 20 min. fire -gated door) R309.1
`_Two Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1
--Twin hones & Townhouses (2 hr separation & 4' overbum protection or parapet) R317.2
�- One hr walls parallel to and within 3 ft of property line w/ NO openings. R302
-'Penetrations in previous 3 items to comply with 8317.3
K. To -
//,Half
ral Requirements
e Numbers R321
Openable 3sf window or Meeh. ,Ventilation in bathrooms, water closets, and similar grooms. R303.3
Interior and exterior star illumination shad comply with R303.6.
Bathroom Fixture clearances comply with Figure 8307.2
//I One room at least 12 0 sf.; Other habitable rooms 70 sf. min wl a min. dimension of 7 ft. R304
*areas w/sloped ceilings less than .5 ft in height & furred ceiliner,s lees than 7 ft D() NOT rnmr►1v
*5d % or mope of the required area mus
t be at least 7ft- high in rooms iv/ sloped ceiling
Egress dearance from
window webs under caniilevered floors,. R310.2
Glazing at Hazardous Locations R308
/Emergency Egress in all sleeping rooms and basements with habitable space R310
//One required Exit Door shall comply with R311.4
Z` Iandz�a s ai to and boitom of staiz-wa -s R311.5.4, and each side of each exterior door. R314.4.3
zz�Stair R.�s� Run (7 3/4"mai. rise c� 10" min. tread, nasir�g req d if <11") �y'Stair Width (3 6 min),
tairww7ay Headroom (68" min.) �andrafls (34"to 38" above stair nosiYlg)(8311.5)
Special conditions for circular, spiral and winder stairways and bulkhead enclosures 8311.5.5
� Stairwa Protection (enclosed accessible space under stairs shah be covered with 1/2" 8311.2.2
/_CI Yin with R311.5.6uard�ails com in� with R3�2 �and�a�s corn
Smoke Alarms eac
L. energy
h bedroom and common area and one on each level) (R 3I3)
Hames with glazing c 15% of gross area of ext. walls (Townhouses e 25%) to comply wI
*Otherwise shall meet requirements qfIECCfor respective building hype. N1101.2
/Vapor retarder on warm 'in winter side of walls, ceiling and floors 8318
,/" *Water Heater heat -traps IECC 504.7
/Duct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3
Plans matchquantxiies & values on a "passing" REScheck compliance report
M. Mechanical
Chapter l 1.
/ Gas appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2
Roam access �4" min �aIdt�ilAttic access 2000/Underear ap�ninfloor x.o. 22x30. X1305
Potential vent/connector offset > 75% of total height (Exception provided by G2428) G2427.6.4
/Dryer Vent length ZS' max w/ 8' transition (-5' per 90 deg turns) M1501.3
Gay "point of delivery" and material used to determine pipe sizing. X2413