Loading...
HomeMy WebLinkAboutRESCHECK - 05-00363 - 672 Centennial Loop - New SFR�z RFScheck Compliance Certificate 2000 IECC REScheck Soffware Version 3.6 Release Z Data filename: Unfitied.rck CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.20 DATE; 09/21/05 DATE OF PLANS: 9 -21 -OS PROJECT DESCRIPTION: S UT HSR LANI] DEV. SPEC #2 COMPLIANCE, Passes Maximum UA = 46f Your Horne LTA = 424 9.0% Better Than Cade ([IA} - 4P Permit Number Checked By/Date 1 ! 1 SFR - 672 Centennial Loop Gross Glazing Area or Cavity Cont. or Door E.C.6=er -R-Value, E -Value actQr _UA Ceiling 1: Flat Ceiling or Scissor Truss 1814 0.0 40.0 44 � ss Wall I; Woad Frame, 16" o. c., 2007 21 U �3.Q 92 � 1'3 Window Window 1Vinyl Frame -,Double. Daub�e Pane 379 0.350 133 Door 1: Glass 5614 r� - yo �F �-� 0.35 � Basement'V�ali 1: Solid Concrete oz-Masortzy X784 I3.0 0,0 Wall height: $.0' 105 Depth below grad: 7.07 Insolation depth: 8.0' Fuznace I.- Forced Hot Air, 9Q .AFUE COMPLIANCE STATEMENT; The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has hem designed to meet the 2000 IECC requirements in REScheck Version 3.6 Release 2 (ibnnerly MECcheck) and to comply with the mandatory requirements listed. in the REScheck Inspection Checkl A I St. Builder/Designer /&-Loo� 31 ia RIEScheck Inspection Checklist ZD -00 IEC REScheck Software Version 3.6 Release 2 DATE: 09/21/05 10� Bidg- Dept. � Use � � Ceilings* [ � � 1. CeiIing L Flat Ceiling or Scissor Truss, R-40.0 continuous insulation � Comments: ] � Z• Ceiling 2: Flat Ceiling or Scissor Truss, R-19.0 continuous insulation � Comments: � Ahvve-Grade Walls: I . Wali 1: Wood game, 16" ox,, R-21.0 cavity insulation Comments: I j ]Basement Walls: [ ] � I. Basement Wall I.- Solid Concrete or Masonry, 8.4' ht/7,0' bgl8.0' insul, R-13.0 cavity insulation � Comments.- Windows, omments:17Vxndaws; [ ] � 1. Window]- Vinyl Frarne:Double Pare, U -factor - 0.350 j For windows without labeled U-factoirs, describe features: � # Panes Frame Type Thermal Break? Yes � j No � Comments: � Aaors: [ ] J 1. Door �: Glass, U_&tor O.3SQ � Commits: � Heating and Coaling Equipment: 1- Pomace i : Forced Hot Air, 90 AFUE or higher Make and Model Number 1 � .max Leakage: [ ] � Joints, penetrations., and all other such openings in the building envelope that are svurce;s ofair r Leakage must be sealed. [ � f Re=sed fights roust be 1) Type IC rated, or 2) insta.Iled inside an appropriate air -tight assembly � with a 0. S " cI�ace from combustible materials_ Ifnon IC raid, the fixture must be installed with a � 311 cls-�noe �Om i�s�i�ion. i � Vapor ,Retarder: � ] i Required an the warm -in -winter side ofaiI non -vented framed ceilings, wallS, and ffaors. j Materials Identifica#ian: � ] j Materials end equipment mush be installed in accordance with the manufactu�s installation instructions- 114 Maten'als wid equipment must be identified so that campliance can he determinad_ Manaficturer manuals for all installed heating and cooling equipment and service water heating equipment mast De provided. Insulation R. -values, glazing U-fietors, and heating equipment efficiency must be dearly marked on the building pians or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated. to R-5. Ducts outside the building must be insulated to R -g, 0, Duct Constmefion All, joints, scams,, and 00nnedions must be securely fistened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-thTic5ortapes. Tapes mid Mastics must berated UL 181AorUL 181B. jr_xceptron: t;OnfinuQusly welded and locking -hype longitudinal joints and stens on ducts Operating at less than 2 in. w.g. (S00 Pa). The HVAC system must provide a means for balancing air and water systems. Temperature Controls: T hermostats are required for each separate HVAC system. A manual or automati c means to Partial ly restrict or shut of the heating and/or cooling input to each zone or ftoor shall he provided, Service Water Heating: Water heaters with vertical pike risers must have a heat tray on both the inlet and outlet unless the water heater has an integral head trap or is part of a circuiating system. Insulate circulating hat waterpipes to the levels in Table I. Circulating mat Wader Systems: Insulate circulating hat waxer pipes to the levels in Table 1. Swimming Pools: All heated swimming goon mush have an an/oifheater switch and requixe a cover unless over 20% of the heating energy is from non-depletabie sources. Pool pumps require a time clock. Heating and C-001ing Piping Insulation: HVAC piping conveying fluids above 105 OF levels in Table 2. Or chilled luids below SS T must be insulated to the Table 1: Minimum Insulation Thicknessfor Circulating Hot Water Inulation Thid in Inches bv P. 12e Heath Water y 11n,to 1.25 IT 1.0 0.5 0.5 Tabte.Z- Minimum fftsulation Thickness for MVAC Pipes. Fluid Temp. Insulation Thl'ckn Pfnin� ��/'C�PtYI T+tmac+ an R 1unout er 211 2.0 1.s 1.0 n T 2 TT 1.25" to 21P tn All meating systems Low PressureJTemperature Low T emp erase Steam ent (fir Ovate Cooling Systems. Chilled Water, Refrigmnt,, and Brine A 201-250 Lo 1.5 1. 1204200 0.5 1.0 1. Any 1.0 1. 40-55 0.5 0.5 0.75 I.0 Below 40 1.0 1.0. !.5 1.5 NOTES TO FIELD (Building Department Use Only) ':� I '�� REScheek Compliance Certificate 2003 IECC REScheck Software Verson 3.6 Release la Data filename: C.'\Program FileslChecklRESchecklBasic.z-ck CITY: Rexburg STATE.- Iah HDD*- 8693 CONSTRUCTION TYPE: Single Family WINDOW 00' ALL. RAT IOC 0,20 DATE: 10/1, COMPLIANCE: Passes. Maximum UA = 441 Your Home UA. 400 9.3% Better Than Cade (STA) Ceiling t1.1 in r Scissor Truss Wall 1. Wood Frarne, 1611 O.C. Window I : Vinyl Frame. -Double Pane with L - Door 1-. S 011" Door ; Glass asem ent W all t t S oll d C oncreter &son Wall height: 8.01 Depth below grade: Insulation depth- 8.0r WindVinyl Frame -Double Pan ith LAS Fumace I.- Forced Hot Air, 90 AFUE iw� 1?5'PM"_ e7o 3&-.s Permit Number Checked By/'Date Gro m r g Area. or Cavity C 011t, or Door Perimeter a-1 U^ -Factor 1814 12.0 28.0 44 zoo? 21.0 o. o 93 313 0.350 110 40 0.354 14 20 0.500 10 1784 13.0 0.0 101 84 0.350 28 COMPLIANCE STATEMENT-, The proposed building design described here is cons2stent with the building plans, specifications, and other calculations submitted with the pennit application. The proposed building Inas been dcsi�zaed to meet the 2043 IECC requirements in RESchc�ck Version 3.6 Release la (fon-nerly MECc�ieck) and to comply with the mandatary requirements listed in the REScheek Inspection Checklist. Builder/Designer Date