Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS REDLINED REVISIONS - 21-00728 - City of Rexburg - TWAS Tank Dome Cover
Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : City of Rexburg - TWAS Tank Dome CoverAddress : 525 N 5th WApplication Type : Document Filename : PLANS - 21-00728 - 525 N 5th W - TWAS Tank Dome Cover.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments 001-8581D1A1 Free text Cody Jones : Building Open 1 Need an Idaho licensed Engineer stamp on plans.Need to identify special inspector for bolt ups, per chapter 17.Roof snow load of 35 psf.Seismic D.Wind 90 mph. # 21-00728Commercial Accessory Structure Report Date: 10.05.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) PLAN VIEW ELEVATION VIEW CODEPAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM RN DOME STANDARD INSTALLATION DETAILS18581D1A2B1 RN CENTER RING GENERAL ARRANGEMENT1CRGA05B2 RN DOME STANDARD INSTALLATION DETAILS (ACC.)18581D1A3B3 RN3 TEMPORARY SAFETY TIE OFF ASSEMBLY2SFTTIEOFF5AB4 -N 300 SERIES SSWIREROPE P3/8" 7X19 STRAND17WIREROPESS38-5 -N 300 SERIES SSWIRE ROPE CLIP AND THIMBLE KIT23372T45-6 -N 300 SERIES SSROPE GRAB CLIP 3/8"18201T68-7 8 -N 7075-T733/8" x 1 1/4" LOCK BOLT GRIP #10803BLTLK03751250-9 -N 60613/8" HUCK BOLT COLLAR803COLLK0375-10 -N A2BOLT 7MM X 20MM10BLTHSM720MMA2-11 -N A2WASHER FLAT 7MM10WSHCS7MMA2-12 -N 18-8 SS1/4" X 3/4" SS TRILOBE SCREW W/ WASHER374SCWTRI02500750188-13 -N F593C1/2" X 1 1/4" HEX HD. BOLT17BLTHS05001250F593C-14 -N F593C1/2" X 3 3/4" HEX HD. BOLT21BLTHS05003750F593C-15 -N F593C1/2" X 4" HEX HD. BOLT21BLTHS05004000F593C-16 -N 18-8 SSWASHER 1/2" (LOCK)59WSHLS0500188-17 -N A316NUT 1/2" HEX HEAD59NUTHS0500316-18 -N 18-8 SSTEK SCREW #14 X 1 1/4"407SCWTEK141250188-19 -N 18-8 SSTEK SCREW #14 X 3/4"187SCWTEK140750188-20 -N 18-8 SSTEK SCREW #14 X 3"36SCWTEK143000188-21 -N ALUMINUMDRIVE RIVET 3/8 X 0.781"63RIVDAL38198-22 -N ALUMINUMPOP RIVET P3/16" 126-.250" GRIP AB6-4ACLD ALUM.95RIVPALSL316250-23 -N ULM SILICONEPECORA 890 SILICONE SEALANT 20oz SG TUBE ALUM13PEC890SAA20OZ-24 25 -N3ALUM 1100-0HUB COVER FOR P16 HUBS6HC16B26 -N4ALUM 1100-0HUB COVER FOR P19 HUBS10HC19B27 28 -N76061-T6HUB TOP #1-1618581D1HT1B29 -N76061-T6HUB BOTTOM #1-1618581D1HB1B30 -N76061-T6HUB UNIVERSAL #2-1668581D1HU2B31 -N76061-T6HUB TOP #2A-16, FOR TEMPORARY TIE-OFF28581D1HT2AB32 -N76061-T6HUB BOTTOM #2A-16, FOR TEMPORARY TIE-OFF28581D1HB2AB33 -N106061-T6HUB TOP #3-1958581D1HT3B34 -N106061-T6HUB BOTTOM #3-1958581D1HB3B35 -N106061-T6HUB TOP #4-1958581D1HT4B36 -N106061-T6HUB BOTTOM #4-1958581D1HB4B37 38 -N106005A-T6/6061-T6BEAM #158581D1S1B39 -N126005A-T6/6061-T6BEAM #258581D1S2B40 -N106005A-T6/6061-T6BEAM #358581D1S3B41 -N146005A-T6/6061-T6BEAM #4108581D1S4B42 -N126005A-T6/6061-T6BEAM #5108581D1S5B43 44 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #158581D1B1B45 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #258581D1B2B46 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #358581D1B3B47 -N36005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #4108581D1B4B48 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #5108581D1B5B49 50 -N123003-H16PANEL #148581D1P1B51 -N103003-H16PANEL #1 W/VENT PUNCHING18581D1P1VB52 -N143003-H16PANEL #258581D1P2B53 -N173003-H16PANEL #358581D1P3B54 -N143003-H16PANEL #438581D1P4B55 -N113003-H16PANEL #4 W/ MANWAY CUTOUT18581D1P4MB56 -N143003-H16PANEL #4 W/NOZZLE CUTOUT18581D1P4NB57 58 -N143003-H16FLASHING108581D1FLB59 -N3ALUM 3003COUNTER FLASHING108581D1CF1B60 -N2ALUM 3003COUNTER FLASHING108581D1CF2B61 -N1ALUM 3003NOTCHED COUNTER FLASHING168581D1CFRTB62 -N0ALUM 3003.050" X 2" X 51" ALUM.10CFSPL051-63 -N0ALUM 3003.050" X 2" X 6" ALUM.20CFSPL006-64 65 RN91 PIER LAYOUT18581D1PRGAB66 RN48 24 IN DOME SQ. MANWAY1MWSQ24B67 RN32 20" DIA. VENT ASSEMBLY W/ BIRD SCREEN1VAB20BALB68 -I/E25 4" 150# R.F.S.O. HILLSIDE NOZZLE18581D1NZL04B69 -N2EPDMFLASHING BOOT #19SQ101BA-70 -N2EPDMFLASHING BOOT #21SQ201BA-71 72 -N ALUM 6061-T6ALUM. SURFACE MOUNT HINGE (NO HOLES)8SURFMNTHNGALNH-73 -N F593C3/8" X 1 1/4" HEX HEAD BOLT34BLTHS03751250F593C-74 -N A3043/8" FLAT WASHER34WSHFS0375304-75 -N A3163/8" HEX NUT34NUTHS0375316-76 -N6ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1001B77 -N11ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1002B78 -N5ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1003B79 -N ALUM 6061-T63" X 3" X 3/8" X 148" LG. ALUM. ANGLE1DOMEANG33375148-80 -N LT GRAY RAL7035 TOP COAT (POWDER)1PNTP7035DV-81 -N LT GRAY PRIMER (POWDER)1PNTPPGDV-82 -N LT GRAY RAL7035 TOP COAT BASE (TU)1PNTP7035DVTU-83 -N TOP COAT CATALYST (TU)1PNTPMT330DVTU-84 -N PRIMER CATALYST (TOUCH UP)1PNTLPCATTU-85 -N PAINT BRUSH 1/2IN4PNTBRH12-86 -N PRIMER BASE (TOUCH UP)1PNTLPGTU-87 ACCESSORY ORIENTATION CHART RADIUSREF DEGREESIZESERVICEITEM 9'-3 3/16"344.2524"24 IN DOME SQ. MANWAY67 2'-10 9/32"146.2520"20" DIA. VENT ASSEMBLY W/ BIRD SCREEN68 9'-11"57.254"4" 150# R.F.S.O. HILLSIDE NOZZLE69 F.L.F.L.#1FLASHING BOOT #170 F.L.F.L.#2FLASHING BOOT #271 0 PROJ # 1/16" 5/32"1/8"1/16" X = 1.0 / X.X = 0.5 1/32" 1/32" 0 - 4" HOLE TO HOLE TOLERANCE:1/32" 3/16"LINEAR TOLERANCE: ANGULAR DEVIATION 130" - 240" TOLERANCES UNLESS OTHERWISE NOTED 240"+ PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 4" - 48"48" - 130" 1/16"DWG # SCALE: NTS JOB # PARENT: 1/32" THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.PROJECT LOCATION:CHECKED BYDRAWN BYDATEREVISION DESCRIPTION CUSTOMER NAME: PROJECT NAME: D 8581D1A1 REV DWG SIZE: 08581 D1 CERTIFIED: APPROVED FOR CONSTRUCTIONSTORTEK REXBURG DOME COVER REXBURG, IDRELEASED FOR FABRICATION JRB JWC8/31/2021 ALUMINUM GEODESIC DOME FOR A 24'-7 3/8" TANK ASSY. WT:1599# 3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999 LINEAR TOLERANCE: SQUARENESS TOLERANCE: 3/32" +0" / -1/8" COLUMN TOLERANCES 1 2 3 4 2 A 3 4 2 3 4 2 A 3 4 2 3 4 P 1 P 1 P 1 P 1 V P 1 P 2 P 3 P 3 P 4 P 4 N P 2 P 3P4M P 2 P 3 P 4 P 2 P 3 P 4 P 2 1 2 3 4 4 5 5 1 2 3 44 55 1 2 3 4 4 5 5 1 2 3 4 4 5 5 1 2 3 4 4 5 5 DESIGN CRITERIA: DESIGN (PER AWWA D108-19) WIND DESIGN: 90 mph PER ASCE 7-05 ROOF LIVE LOAD: 25 PSF GROUND SNOW LOAD: 50 PSF DESIGN PRESSURE/VACUUM: ATMOSPHERIC OPERATING PRESSURE/VACUUM: ATMOSPHERIC 24'-7 3/8" NOMINAL TANK I.D. 4 '-1 " 68 0 270 180 904 4 68 67 69 71 79 78 77 70 80 Need an Idaho licensed Engineer stamp on plans. Need to identify special inspector for bolt ups, per chapter 17. Roof snow load of 35 psf. Seismic D. Wind 90 mph.