HomeMy WebLinkAboutPLANS ENGINEERED - 21-00728 - City of Rexburg - TWAS Tank Dome CoverPROJ #
1/16"5/32"1/8"1/16"X = ±1.0° / X.X = ±0.5°
1/32"1/32" 0 - 4"
HOLE TO HOLE TOLERANCE:1/32"3/16"LINEAR TOLERANCE:
ANGULAR DEVIATION
130" - 240"
TOLERANCES UNLESS OTHERWISE NOTED
240"+
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
4" - 48" 48" - 130"
1/16"DWG #SCALE: NTS
JOB #
PARENT:
1/32"
THE INFORMATION ON THIS DOCUMENT ISCONFIDENTIAL PROPERTY OF TANKMANUFACTURER AND/OR ITS AFFILIATES. ANYOTHER USE, RETENTION, DISSEMINATION,FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES ISSTRICTLY PROHIBITED, WITHOUT THEEXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.PROJECT LOCATION:CHECKED BYDRAWN BYDATEREVISION DESCRIPTION
CUSTOMER NAME:
PROJECT NAME:
REV DWG SIZE:
ASSY. WT:#
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999
LINEAR TOLERANCE:
SQUARENESS TOLERANCE: ±3/32"
+0" / -1/8"
COLUMN TOLERANCES
0
1
D 8581D1A1
08581 D1
CERTIFIED: APPROVED FOR CONSTRUCTIONSTORTEK
REXBURG DOME COVER
REXBURG, IDRELEASED FOR FABRICATION JRB JWC8/31/2021
ALUMINUM GEODESICDOME FOR A Ø24'-7 3/8"
TANKREV'D DESIGN NOTES 9/15/2021 JWC JRB
1599
DESIGN CRITERIA:DESIGN (PER IBC 2018)WIND DESIGN: 112 mph PER ASCE 7-16ROOF LIVE LOAD: 25 PSFGROUND SNOW LOAD: 50 PSFDESIGN PRESSURE/VACUUM: ATMOSPHERICOPERATING PRESSURE/VACUUM: ATMOSPHERIC
PLAN VIEW
ELEVATION VIEW
1
2
3
4
2A
3
4
2
3
4
2A
3
4
2
3
4
P1
P1
P1
P1V
P1
P2
P3
P3 P4
P4N
P2
P3P4MP2
P3
P4
P2
P3
P4 P2
1
2
3
4
4
5
5
1
2
3
44
55
12
3
4
4
5
5
1
2
3
4
4
5
5
1
2
3
4
4
5
5
24'-7 3/8" NOMINAL TANK I.D.
4'-
1
"
CODEPAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM
RNDOME STANDARD INSTALLATION DETAILS18581D1A2B1
RNCENTER RING GENERAL ARRANGEMENT1CRGA05B2
RNDOME STANDARD INSTALLATION DETAILS (ACC.)18581D1A3B3
RN3TEMPORARY SAFETY TIE OFF ASSEMBLY2SFTTIEOFF5AB4
-N300 SERIES SSWIREROPEP3/8" 7X19 STRAND17WIREROPESS38-5 -N300 SERIES SSWIRE ROPE CLIP AND THIMBLE KIT23372T45-6
-N300 SERIES SSROPE GRAB CLIP 3/8"18201T68-7
8
-N7075-T733/8" x 1 1/4" LOCK BOLT GRIP #10803BLTLK03751250-9 -N60613/8" HUCK BOLT COLLAR803COLLK0375-10
-NA2BOLT 7MM X 20MM10BLTHSM720MMA2-11 -NA2WASHER FLAT 7MM10WSHCS7MMA2-12
-N18-8 SS1/4" X 3/4" SS TRILOBE SCREW W/ WASHER374SCWTRI02500750188-13 -NF593C1/2" X 1 1/4" HEX HD. BOLT17BLTHS05001250F593C-14
-NF593C1/2" X 3 3/4" HEX HD. BOLT21BLTHS05003750F593C-15 -NF593C1/2" X 4" HEX HD. BOLT21BLTHS05004000F593C-16
-N18-8 SSWASHER 1/2" (LOCK)59WSHLS0500188-17 -NA316NUT 1/2" HEX HEAD59NUTHS0500316-18
-N18-8 SSTEK SCREW #14 X 1 1/4"407SCWTEK141250188-19
-N18-8 SSTEK SCREW #14 X 3/4"187SCWTEK140750188-20
-N18-8 SSTEK SCREW #14 X 3"36SCWTEK143000188-21
-NALUMINUMDRIVE RIVET 3/8 X 0.781"63RIVDAL38198-22
-NALUMINUMPOP RIVETP3/16" 126-.250" GRIP AB6-4ACLD ALUM.95RIVPALSL316250-23
-NULM SILICONEPECORA 890 SILICONE SEALANT 20oz SG TUBE ALUM13PEC890SAA20OZ-24
25
-N3ALUM 1100-0HUB COVER FOR P16 HUBS6HC16B26
-N4ALUM 1100-0HUB COVER FOR P19 HUBS10HC19B27
28
-N76061-T6HUB TOP #1-16Ø18581D1HT1B29
-N76061-T6HUB BOTTOM #1-16Ø18581D1HB1B30 -N76061-T6HUB UNIVERSAL #2-16Ø68581D1HU2B31
-N76061-T6HUB TOP #2A-16Ø, FOR TEMPORARY TIE-OFF28581D1HT2AB32 -N76061-T6HUB BOTTOM #2A-16Ø, FOR TEMPORARY TIE-OFF28581D1HB2AB33
-N106061-T6HUB TOP #3-19Ø58581D1HT3B34 -N106061-T6HUB BOTTOM #3-19Ø58581D1HB3B35
-N106061-T6HUB TOP #4-19Ø58581D1HT4B36 -N106061-T6HUB BOTTOM #4-19Ø58581D1HB4B37
38 -N106005A-T6/6061-T6BEAM #158581D1S1B39
-N126005A-T6/6061-T6BEAM #258581D1S2B40 -N106005A-T6/6061-T6BEAM #358581D1S3B41
-N146005A-T6/6061-T6BEAM #4108581D1S4B42 -N126005A-T6/6061-T6BEAM #5108581D1S5B43
44
-N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #158581D1B1B45
-N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #258581D1B2B46
-N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #358581D1B3B47
-N36005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #4108581D1B4B48
-N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #5108581D1B5B49
50
-N123003-H16PANEL #148581D1P1B51
-N103003-H16PANEL #1 W/VENT PUNCHING18581D1P1VB52
-N143003-H16PANEL #258581D1P2B53
-N173003-H16PANEL #358581D1P3B54
-N143003-H16PANEL #438581D1P4B55 -N113003-H16PANEL #4 W/ MANWAY CUTOUT18581D1P4MB56
-N143003-H16PANEL #4 W/NOZZLE CUTOUT18581D1P4NB57
58
-N143003-H16FLASHING108581D1FLB59 -N3ALUM 3003COUNTER FLASHING108581D1CF1B60
-N2ALUM 3003COUNTER FLASHING108581D1CF2B61 -N1ALUM 3003NOTCHED COUNTER FLASHING168581D1CFRTB62
-N0ALUM 3003.050" X 2" X 51" ALUM.10CFSPL051-63 -N0ALUM 3003.050" X 2" X 6" ALUM.20CFSPL006-64
65
RN91PIER LAYOUT18581D1PRGAB66
RN4824 IN DOME SQ. MANWAY1MWSQ24B67
RN3220" DIA. VENT ASSEMBLY W/ BIRD SCREEN1VAB20BALB68
-I/E254" 150# R.F.S.O. HILLSIDE NOZZLE18581D1NZL04B69
-N2EPDMFLASHING BOOT #19SQ101BA-70
-N2EPDMFLASHING BOOT #21SQ201BA-71
72
-NALUM 6061-T6ALUM. SURFACE MOUNT HINGE (NO HOLES)8SURFMNTHNGALNH-73
-NF593C3/8" X 1 1/4" HEX HEAD BOLT34BLTHS03751250F593C-74
-NA3043/8" FLAT WASHER34WSHFS0375304-75
-NA3163/8" HEX NUT34NUTHS0375316-76
-N6ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1001B77
-N11ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1002B78
-N5ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1003B79
-NALUM 6061-T63" X 3" X 3/8" X 148" LG. ALUM. ANGLE1DOMEANG33375148-80 -NLT GRAY RAL7035 TOP COAT (POWDER)1PNTP7035DV-81
-NLT GRAY PRIMER (POWDER)1PNTPPGDV-82 -NLT GRAY RAL7035 TOP COAT BASE (TU)1PNTP7035DVTU-83
-NTOP COAT CATALYST (TU)1PNTPMT330DVTU-84 -NPRIMER CATALYST (TOUCH UP)1PNTLPCATTU-85
-NPAINT BRUSH 1/2IN4PNTBRH12-86 -NPRIMER BASE (TOUCH UP)1PNTLPGTU-87
68
°0
°270
°180
°904
4
68
67
ACCESSORY ORIENTATION CHART
RADIUSREF DEGREESIZESERVICEITEM
9'-3 3/16"344.25°24"24 IN DOME SQ. MANWAY67
2'-10 9/32"146.25°Ø20"20" DIA. VENT ASSEMBLY W/ BIRD SCREEN68
9'-11"57.25°Ø4"4" 150# R.F.S.O. HILLSIDE NOZZLE69
F.L.F.L.#1FLASHING BOOT #170
F.L.F.L.#2FLASHING BOOT #271
69
71
79
78
77
70
80
1
Digitally signed
by Joshua
Jensen
Date: 2021.09.15
20:46:40 -05'00'
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
NOTES:
ALL MATERIAL IS MILL FINISH ALUMINUM UNLESS NOTED
PANELS, FLASHING AND HUB COVERS 3003-H16 OR 5052-H32
HUBS AND PLATES 6061-T6 OR 5052-H32
BEAM AND BATTEN STRIPS 6005A-T6 OR 6061-T6
FASTENERS
HUCK BOLTS - ALUMINUM 7075-T7 - ANODIZED FINISH
DETAIL E
PANEL LABELING
ORIENTATION MARK IS ON
THE RIGHT SIDE OF THE
HOLE WHEN VIEWED
FROM THE TOP
PANEL CORNER MARKS ARE
LABELED W/ "P" PANEL NUMBER
AND "B" BEAM NUMBER OPPOSITE
SIDE OF PANEL CORNER
P1 B1
HUB COVER
SEALANT AROUND ENTIRE
HUB COVER PERIMETER
3/8" DIA. ALUM HUCK BOLT AND COLLAR. EACH
END OF BEAM FLANGE TO DOME HUB MIN OF 4
PLC'S TOP & BOTTOM FLANGE
BOTTOM HUB
TOP HUB FIELD APPLY SEALANT ON COVER,
HUB, BATTEN AND PANEL GAPS
#14 X 3"
TEK SCREW
W/ WASHER
APPLY SEALANT BETWEEN WASHER AND HUB COVER
DOME PANEL
DETAIL D
TYPICAL DOME BEAM CONNECTION
DETAIL C
TYPICAL HUB, COVER & BATTEN INSTALLATION DOME FLASHING
DOME PANEL .050" ALUM
BATTEN BAR W/ GASKET
DOME STRUT
PIERTOP HUB
HUB COVER
#14 X 3" TEK SCREW W/ WASHER APPLY
SEALANT BETWEEN WASHER AND HUB COVER
1/4" X 3/4" TRILOBE
SCREW W/ WASHER
FIELD APPLY SEALANT ON COVER,
HUB, BATTEN AND PANEL GAPS
FLASHING OVERLAPS HUB
(FIELD CUT AS NEEDED)
DOME PANEL
3/8" DRIVE RIVET THRU PANEL INTO HUB
ALIGNMENT HOLE. TYP ALL 3 PANEL CORNERS
3/8" DIA. ALUM HUCK FASTENER TYP
ALL HUB TO STRUT CONNECTIONS
REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS
JOB #
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANKMANUFACTURER AND/OR ITS AFFILIATES. ANY
OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.DWG SIZE: B
DWG #
TOLERANCES UNLESS OTHERWISE NOTED
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
130" - 240"
LINEAR TOLERANCE:
HOLE TO HOLE TOLERANCE:
240"+48" - 130"4" - 48"0 - 4"
ANGULAR DEVIATION
1/32"
1/32"
1/16"
1/32"
5/32"
1/32"
1/8"
1/16"
3/16"
1/16"
X = ±1.0° / X.X = ±0.5°
TOTAL WT: PARENT:
PROJ #
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.39993RD ANGLE
PROJECTION
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS 08581 D1
DOME STANDARD
INSTALLATION DETAILS
ACCESSORIES
NOT APPROVED FOR CONSTRUCTION 6/25/2021 JRB MC
REL'D FOR FAB 8/31/2021 JWC JWC1
0 002-8581D1A2
CERTIFIED: APPROVED FOR CONSTRUCTION
DETAIL B
FLASHING & COUNTER FLASHING INSTALLATION
RETAINER IS NOTCHED TO CLEAR EAVE
ANGLE WASHERS, EVERY 4TH NOTCH IS
SECURED BEHIND THE EAVE BOLT WASHER
INNER COUNTER FLASHING
OUTER COUNTER FLASHING
#14 X 3/4" SS TEK SCREWS TYPICALLY SPACED AT 8" BUT
USE AS REQ'D TO CLOSE ALL RETAINER & FLASHING GAPS
PLACE 3 #14 x 1 1/4" TEK SCREWS EITHER SIDE OF SEAM IN
SUPPORT BLOCK. PREDRILL 3/16"Ø HOLES
TANK EAVE ANGLE
BEND UNDER LAP TAB AND APPLY SEALANT AS REQ'D
FOR WEATHER TIGHT SEAL AT ALL FLASHING JOINTS
DOME FLASHING (TO BE INSTALLED CLOCKWISE TO ACHIEVE
CORRECT LAP)
COUNTER FLASHING RETAINER FIELD
FORMED TO EAVE ANGLE O.D.FIELD CUT COUNTER FLASHING STRIP TO CORRECT LENGTH
AND SEAL ANY GAPS BETWEEN COUNTER FLASHING JOINTS.
USE SEALANT AND FASTEN WITH ALUMINUM RIVETS.
#14 X 1 1/4" SS TEK SCREWS
INNER
COUNTER
FLASHING
LEAVE 1" GAP BETWEEN OUTER FLASHING
EDGE AND TEK SCREW FOR MOVEMENT
COUNTER FLASHING SPLICE:FIELD CUT COUNTER
FLASHING STRIP TO CORRECT LENGTH AND SEAL
ANY GAPS BETWEEN COUNTER FLASHING JOINTS.
USE SEALANT AND FASTEN WITH ALUM RIVETS.
USE #14 X 1 1/4" SS TEK SCREWS AS REQ'D
#14 X 1 1/4" SS TEK SCREWS
AT PIER FLASHING SHIMS
BATTEN
1/4" X 3/4" TRILOBE SCREW W/ WASHER
DOME FLASHING
PIER
HUB COVER
FIELD APPLY SEALANT TO CREATE WEATHERPROOF
SEAL BETWEEN FLASHING AND HUB COVER
#14 X 1 1/4" SS TEK SCREWS AT SEAM LOCATIONS
PIER SHIM (NEOPRENE)
TIGHTEN AFTER ASSEMBLY
NOTCHED
FLASHING
INNER COUNTER FLASHING
OUTER COUNTER FLASHING
USE SEALANT BETWEEN
FLASHING & TANK SIDEWALL
OUTER COUNTER FLASHING
DETAIL A
FLASHING INSTALLATION
EAVE ANGLE AND TANK SIDEWALL
#14 X 3/4" SS TEK SCREWS SPACED
AROUND AT 8" OR AS REQ'D
10°
APPROX 1"
1" APPROX.
NYLON FLASHING SHIM
STANDARD FLASHING
TO EAVE CONNECTION
1"
RE
F
.
TANK GIRDER
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
TOP & BTMHUBS
AA
SECTION A-A
HUB COVER
APPLY SEALANT BETWEENHUB COVER AND HOISTRING BASE
CENTER RING SAFETY TIE OFF
POINT AT APEX 5000# MAX LOAD
2
1
4
3
FIELD DRILLFOR 3/4" BOLT
3
3
3
4
REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS
JOB #
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANKMANUFACTURER AND/OR ITS AFFILIATES. ANY
OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.DWG SIZE: B
DESCRIPTIONQTYPART NO.D/SITEM MAT'L. GR. EST. WT.PAINT
DWG #
TOLERANCES UNLESS OTHERWISE NOTED
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
130" - 240"
LINEAR TOLERANCE:
HOLE TO HOLE TOLERANCE:
240"+48" - 130"4" - 48"0 - 4"
ANGULAR DEVIATION
1/32"
1/32"
1/16"
1/32"
5/32"
1/32"
1/8"
1/16"
3/16"
1/16"
X = ±1.0° / X.X = ±0.5°
TOTAL WT: PARENT:
PROJ #
CODE
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.39993RD ANGLE
PROJECTION
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS --- ---
CENTER RING GENERAL
ARRANGEMENT
FOR SAFTEY TIE OFF
8
SWITHCED TO NEW BORDER 9/8/2014 BDS JLP
HARDWARE UPDATE 6/14/2016 MLH JLP
HARDWARE UPDATE 6/28/2016 MLH JLP
UPDATE BORDER 9/20/2020 PROG AUTO
UPDATED BORDER 11/17/2020 BLD JWC6
5
4
3
2
---
003-CRGA05
CERTIFIED: APPROVED FOR CONSTRUCTION
1 B CRSB05 1 CENTER RING SUPPORT BLOCK 2 X 2 X 6.875 LG. 6061 T6 3 --
2 - 3046T75 1 LARGE OPENING HOIST RING 17-4 PH SS 5 --
3 - WSHLS0750304 1 WASHER LOCK 3/4" 304SS 304SS ---
4 - BLTHS07501500304 1 BOLT 3/4" X 1 1/2" HEX HD 304SS 304SS ---
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
3" X 3" X 3/8" ALUM
REINFORCING ANGLE
FIELD CUT TO FIT
BETWEEN DOME
STRUTS WITH
MINIMUM CLEARANCE
(HEELS IN)
DOME ACCESSORY
APPROXIMATE 1" GAP
BETWEEN DOME ACC.
AND SUPT. ANGLE
DETAIL B
TYPICAL ACCESSORY PENETRATION
REINFORCEMENT ANGLE
DOME PANEL
D
D
IF ACCESSORY CUT EDGE IS
WITHIN 18" OF STRUT, SECOND
SUPT. ANGLE NOT REQ'D.
(3) 3/8" 304SS THIMBLE AND CLIP KIT,
INSTALL CLIPS MAX OF 5" APART
3/8"Ø S.S.
WIRE
LOOP CABLE AND THIMBLE
THROUGH CENTER SUPPORT RING
FIELD APPLY SEALANT BETWEEN CENTER
SUPPORT BLOCK AND HUB COVER
EXTEND ROPE TO ACCESS LADDER
OR PLATFORM AND CUT TO
LENGTH, ATTACH TO PLATFORM
3/8" WIRE ROPE GRAB 304 SS
INSTALL PER MFG. INSTRUCTIONS
DETAIL A
CENTER SAFETY GRAB CABLE INSTALLATION
LEGEND
5
8
9
9
9
12
P12
PANEL #
HUB #
STRUT & BATTEN #
BEAM
DOME PANEL
DOME PANEL
SECTION D-D
TYPICAL ALUM ANGLE
SUPT INSTALLATION
DRILL HOLES IN HINGE,
ANGLE, AND BEAM AS NEEDED
ALUM. HINGE
3" X 3" X 3/8" ALUM. REIN. ANGLE
INSTALL ANGLE FLUSH WITH
DOME PANEL
3/8" SS BOLTS,
WASHERS & NUTS
DETAIL G
ALUMINUM DOME VENT
WITH REINFORCEMENT ANGLE
USE SEALANT
DOME VENT
ATTACH WITH 3/8"
ALUM HUCK BOLTS
3" X 3" X 3/8" ANGLE
(SEE DETAIL C)
DOME PANEL
DOME MANWAY
DETAIL F
DOME MANWAY
WITH REINFORCEMENT ANGLE
USE SEALANT
ATTACH WITH 3/8"
ALUM HUCK BOLTS
3" X 3" X 3/8" ANGLE
(SEE DETAIL 'C')
DOME PANEL
TYPICAL PIER ATTACHMENT DETAILS
TANK INT.
EAVE ANGLE
PIER ASSEMBLY
PIER SHIM
UTILIZE #SCWTEK140750188
FOR ATACHMENT OF
#CFSPL006 ON BOTH SIDES OF
PIER BASE (TO BE REMOVE
AFTER DOME IS INSTALLED)
UTILIZE 1/2" X 4" EXT.
AND 1/2" X 3 3/4" INT.
BOLTS, WASHERS, &
NUTS FOR
ATTACHMENT
WIND GIRDER
REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS
JOB #
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK
MANUFACTURER AND/OR ITS AFFILIATES. ANYOTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.DWG SIZE: B
DWG #
TOLERANCES UNLESS OTHERWISE NOTED
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
130" - 240"
LINEAR TOLERANCE:
HOLE TO HOLE TOLERANCE:
240"+48" - 130"4" - 48"0 - 4"
ANGULAR DEVIATION
1/32"
1/32"
1/16"
1/32"
5/32"
1/32"
1/8"
1/16"
3/16"
1/16"
X = ±1.0° / X.X = ±0.5°
TOTAL WT: PARENT:
PROJ #
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.39993RD ANGLE
PROJECTION
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS 08581 D1
DOME STANDARD
INSTALLATION DETAILS
ACCESSORIES
NOT APPROVED FOR CONSTRUCTION 6/25/2021 JRB MC
REL'D FOR FAB 8/31/2021 JWC JWC1
0 005-8581D1A3
CERTIFIED: APPROVED FOR CONSTRUCTION
RUBBER
MASTER FLASH
BOOT
DOME PANEL
FIELD CUT
DETAIL K
FLASHING BOOT DETAIL
PIPING AND COMPONENTS
NOT TO BE SUPPORTED
BY DOME
ORIENTATION NOTCH
POINTS TO CENTER OF DOME
3" X 3" X 3/8" ANGLE
PANEL
NOZZLEATTACH WITH 1/2" X 1 1/4" SS304
BOLTS, WASHER, AND NUTS
DETAIL J
HILLSIDE NOZZLE DETAIL
WITH REINFORCEMENT ANGLE
(250# MAX LOAD)
USE
SEALANT
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK
MANUFACTURER AND/OR ITS AFFILIATES. ANYOTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.
AFFILIATE GROUP
ConnectionPERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
3/16"
1/16"
PARENT:
X = ±1.0° / X.X = ±0.5°
ANGULAR DEVIATION
TOLERANCES UNLESS OTHERWISE NOTED
HOLE TO HOLE TOLERANCE:
LINEAR TOLERANCE:
1/32"
0 - 4"
1/32" 1/16"
4" - 48"
1/32"
5/32"
48" - 130" 130" - 240" 240"+
1/16"
1/8"
1/32"
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS
3RD ANGLE
PROJECTION REVISION DESCRIPTION
PROJ # JOB #
DWG #DRAWN BY SCALE: NTSCHECKED BYDATE
TOTAL WT:
REV DWG SIZE:
3 lbmass
2
1
0 SFTTIEOFF5A
B
CERTIFIED: APPROVED FOR CONSTRUCTION
RELEASED FOR FABRICATION JWC JRB4/16/2020
REV'D HARDWARE
UPDATED HARDWARE
5/14/2020 JWC JRB
3/4/2021 BLD JRB TEMPORARY SAFETY TIE OFF
ASSEMBLY
PLAN VIEW
A A
SECTION A-AFOR USAGE WITH TIE OFF CABLE
PAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM
-2ALUM 6061-T6SUPPORT BLOCK 2" SQ. X 5 7/8" LG.1SFTTIEOFF5B1
-0F593DBOLT 3/4" x 1 1/2" HEX HD1BLTHS07501500F593D-2
-0A3043/4" LOCK WASHER SS1WSHLS0750304-3
-1F593DBOLT 3/4" x 2 1/2" HEX HD1BLTHS07502500F593D-4
-0A304WASHER FLAT 3/4"1WSHFS0750304-5
SECTION A-A
REMOVE HOIST RING AND INSTALL Ø3/4" BOLT AND WASHER
AT TOP SIDE AFTER INSTALLING COVER.
SAFETY TIE OFF RING
POINT AT APEX
5000# MAX LOAD
1
2 3
1
2 3
4 5
TOP HUB
BTM HUB
TOP HUB
BTM HUB
HUB COVER
1
1
1
12
2
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK
MANUFACTURER AND/OR ITS AFFILIATES. ANYOTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.
PARENT:TOTAL WT:
REV DWG SIZE:
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999
COLUMN TOLERANCES
+0" / -1/8"
±3/32"
SQUARENESS TOLERANCE:
LINEAR TOLERANCE:
SCALE: NTS1/32"
1/8"
JOB #
1/16"DWG #1/16"
5/32"
240"+ 130" - 240"
3/16"
1/32"
1/16"
48" - 130"
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
4" - 48"
1/32"
1/32"
0 - 4"
TOLERANCES UNLESS OTHERWISE NOTED
ANGULAR DEVIATION
LINEAR TOLERANCE:
HOLE TO HOLE TOLERANCE:
X = ±1.0° / X.X = ±0.5°
PROJ #
91 lbmass
0 8581D1PRGA
B
08581 D1
CERTIFIED: APPROVED FOR CONSTRUCTION
RELEASED FOR FABRICATION JRB JWC8/31/2021
PIER LAYOUT
PLAN VIEW
°270 °90
CODEPAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM
R-9PIER ASSEMBLY108581D1PRASMB1
--0NEOPRENE1/4" NEOPRENE SHIM107970D1PRSHIMB2
A
DETAIL A
B
B
SECTION B-B
TYP (10) PLCS
2
1
TANK INT.
TANK EAVE/GIRDER
SECTION B ISOMETRIC VIEW
2
1
°0
6'-8 3/4"
7'-1 11/16"
2 7/8"
8 7/8"
6'-6 1/2"2 3/4"
6'-11 1/2"8 3/4"
7'-2 7/8" T
Y
P
.
C
H
O
R
D
7'-0 3/8" T
Y
P
.
C
H
O
R
D
7'-11 13/16
"
T
Y
P
.
C
H
O
R
D
Ø24'-11 5/8" B.C.
Ø24'-3 5/8" B.C.
8'-2 1/4" T
Y
P
.
C
H
O
R
D
R12'-6 1/16"
R12'-1 9/16"
REMOVED BOLTS CRASHING
WITH PIER BASE
MATCH, MARK AND DRILL.
°0
°180
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK
MANUFACTURER AND/OR ITS AFFILIATES. ANYOTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.
AFFILIATE GROUP
ConnectionPERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
3/16"
1/16"
PARENT:
X = ±1.0° / X.X = ±0.5°
ANGULAR DEVIATION
TOLERANCES UNLESS OTHERWISE NOTED
HOLE TO HOLE TOLERANCE:
LINEAR TOLERANCE:
1/32"
0 - 4"
1/32" 1/16"
4" - 48"
1/32"
5/32"
48" - 130" 130" - 240" 240"+
1/16"
1/8"
1/32"
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS
3RD ANGLE
PROJECTION REVISION DESCRIPTION
PROJ # JOB #
DWG #DRAWN BY SCALE: NTSCHECKED BYDATE
TOTAL WT:
REV DWG SIZE:
9 lbmass
0 8581D1PRASM
B
08581 D1
CERTIFIED: APPROVED FOR CONSTRUCTION
RELEASED FOR FABRICATION JRB JWC8/31/2021
PIER ASSEMBLY
ISOMETRIC VIEW
PAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM
-56061-T6PIER BASE X 6 1/4" LG.18581D1PR1B1
-06061-T6PIER SHOE (DIE #18519) X 2 1/4in LG28581D1PR2B2
-06061-T6PIER LINK (DIE #18517) X 2 1/4in LG18581D1PR3-3
-26061-T6BEAM I-5 X 10 7/8" LG.18581D1PR4B4
-0NYLON 6/10.375 THK FLASHING SHIM1SHIMHDPE383BB5
-0-PTFE TAPE .020 THK X 3in X 2 1/4in LG18581D1PR2_PTFETAPE-6
-0-PTFE TAPE .020 THK X 1in X 2 1/4in LG28581D1PR2_PTFETAPE2-7
-0-PTFE TAPE .020 THK X 3" X 6 1/4" LG.1PTFETAP020315-8
-0-PTFE TAPE .020 THK X 3/4" X 6 1/4" LG.2PTFETAP0203415-9
-0F593DBOLT 3/4" x 2" HEX HD1BLTHS07502000F593D-10
-0A316NUT 3/4" HEX HD1NUTHS0750316-11
-0A304WASHER 3/4" LOCK1WSHLS0750304-12
-0A410#6-20 FLAT HEAD DRILLING SCREW X 3/4" LG2MC94195A120-13
SIDE ASSEMBLY VIEWFRONT ASSEMBLY VIEW
ITEM #1 TAPE DETAIL
(OTHER COMPONENTS HIDDEN FOR CLARITY)
ITEM #2 TAPE DETAIL
(OTHER COMPONENTS HIDDEN FOR CLARITY)
22
22
2
2 1/4" REF
4
5
1
99
1
101112
8
3
77
6
3"1/4"1/4"
3"
3
1
4
13
5
13
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
24
"
S
Q
.
(O
P
E
N
I
N
G
)
S.S. HORIZONTAL
COMPRESSION
SPRING
24" SQ.
(OPENING)
32
5
/
8
"
1/8" THK
EPDM GASKET
COVER
PLATE
L 4 X 3 X 3/16 FRAME
LIFTING
HANDLE
2"
3/16" FLOOR PLATE
MAT'L: ALUM. 3003
S.S. WATERTIGHT
SLAMLOCK
S.S. AUTOMATIC
HOLD OPEN ARM
EXTERIOR STAPLE FOR
PADLOCK (FRAME LUG)
EXTERIOR STAPLE
FOR PADLOCK
(COVER LUG)
VINYL GRIP HANDLE
ON HOLD OPEN ARM
SLAMLOCK
KEY HANDLE
INT. DOME PANEL
INT. DOME PANEL
2
7
/
8
"
8"
8"
8"
2
7
/
8
"
29
3
/
4
"
1 5/16"
DETAIL ITEM #2
8"
8"
8"
25
3
/
4
"
1 5/16"
DETAIL ITEM #3
7/16" DIA HOLES TYP.
FASTEN WITH 3/8" HUCKBOLT
TYPICAL
2 X 2 X 1/4 REINFORCEMENT ANGLE
TYPICAL
3 SPCS @ 8" = 24" SQ.
2"
TY
P
7/
8
"
7/
8
"
APPLY SEALANT BETWEEN
FRAME & PANEL
1
31 5/8"
S.S. PIN HINGES
7/16" DIA HOLE TYP.
1
2
2
2
3
1 3
2
3
1 4
1
/
4
"
4
4
4
4
REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS
JOB #
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANKMANUFACTURER AND/OR ITS AFFILIATES. ANY
OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.DWG SIZE: B
DESCRIPTIONQTYPART NO.D/SITEM MAT'L. GR. EST. WT.PAINT
DWG #
TOLERANCES UNLESS OTHERWISE NOTED
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
130" - 240"
LINEAR TOLERANCE:
HOLE TO HOLE TOLERANCE:
240"+48" - 130"4" - 48"0 - 4"
ANGULAR DEVIATION
1/32"
1/32"
1/16"
1/32"
5/32"
1/32"
1/8"
1/16"
3/16"
1/16"
X = ±1.0° / X.X = ±0.5°
TOTAL WT: PARENT:
PROJ #
CODE
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.39993RD ANGLE
PROJECTION
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS --- ---
24" SQUARE MANWAYTYPICAL
ASSEMBLYFOR DOME
48
CHANGED TO 4" CURB HT. 1/24/2013 BDS DM
CHANGED TO 24" SQ. MANWAY 3/22/2016 BDS JLP
CHANGED ANGLE HEEL DIM PER SHOP 9/30/2013 BEC BDS
UPDATED LOCK STAPLES & REINFOR ANGLE 3/17/2016 MLH JLP
UPDATE BORDER 9/21/2020 PROG AUTO5
4
3
2
1
MWSQ30.dwg
047-MWSQ24
CERTIFIED: APPROVED FOR CONSTRUCTION
1 - DMHALSRRI2424 1 24 IN DOME SQ. MANWAY ALUM/S.S. 38 --
2 - MWSQ24RA1 2 ANGLE 2 X 2 X 1/4 X 29 3/4" LG. 6061-T6 3 --
3 - MWSQ24RA2 2 ANGLE 2 X 2 X 1/4 X 25 3/4" LG. 6061-T6 2 --
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E
2
1
3
4
1
20" MANWAY VENT NECK
DOUBLE NUT (1)
SIDE FOR HINGE
BIRD SCREEN
GASKET
6
5
DOME PANEL
1
2
2
2
REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS
JOB #
THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANKMANUFACTURER AND/OR ITS AFFILIATES. ANY
OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THISDOCUMENT TO UNAUTHORIZED PARTIES IS
STRICTLY PROHIBITED, WITHOUT THE
EXPRESSED WRITTEN CONSENT OF TANKMANUFACTURER.DWG SIZE: B
DESCRIPTIONQTYPART NO.D/SITEM MAT'L. GR. EST. WT.PAINT
DWG #
TOLERANCES UNLESS OTHERWISE NOTED
PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES
130" - 240"
LINEAR TOLERANCE:
HOLE TO HOLE TOLERANCE:
240"+48" - 130"4" - 48"0 - 4"
ANGULAR DEVIATION
1/32"
1/32"
1/16"
1/32"
5/32"
1/32"
1/8"
1/16"
3/16"
1/16"
X = ±1.0° / X.X = ±0.5°
TOTAL WT: PARENT:
PROJ #
CODE
3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.39993RD ANGLE
PROJECTION
***DO NOT SCALE***
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS --- ---
VENT ASSEMBLY 20"Ø ALUM
WITH BIRD SCREEN
35
SWITCHED TO NEW BORDER 9/9/2014 BDS JLP
REVISED LEADER TEXT 8/25/2015 JLP BDS
HARDWARE UPDATE 6/14/2016 MLH JLP
UPDATE BORDER 9/21/2020 PROG AUTO3
2
1
0
---
048-VAB20BAL
CERTIFIED: APPROVED FOR CONSTRUCTION
1 B VCA20B 1 20" ALUM. BIRD VENT CAP ASSEMBLY - 24 --
2 - BLTHS05002000304 2 1/2" X 2" HEX HD BOLT 304SS - ---
3 - NUTHS0500316 4 1/2" HEX NUT - ---
4 - WSHFS0500304 2 1/2" FLAT WASHER 304SS - ---
5 B GSKTE20PRV 1 20" GASKET EPDM - 1 --
6 B VNB20AL 1 20" VENT NECK ALUM - 10 --
DocuSign Envelope ID: 3D51F352-5EC8-4222-90A2-53313F34BC3E