Loading...
HomeMy WebLinkAboutLETTER - 05-00333 - 1198 Pleasant View - New SFRD Y E R G R Q U P ;,- September 19, 2005 Quinton Owens City of Rexburg Building Department P.O. Box 280 Rexburg, ID 83440 Re'. Scoff Jones Residence Pians (J. B. Kay Construction - Contr C -or) Dear Quinton: We have been informed by the contractor, J. B. Kay construction, that you have identified Code concerns on the latera! transfer of forces through the garage area. The purpose of this letter is to respond to these concerns and provide recommended courses of action to address Garage On the garage situation, we will Instruct the contractor to t our standard treatme this situation by adhering to the following specifications: nt dor Construct sheathed braced wails in the corners and abase the headers - Positively angor the system to the concrete , fo using Simpson Strong-WallQion with appropriate anchorage bolts,connectors with SST anchor or appov ed • Make the headers above the garage door openings continuous and expend them into the sheathed wall area in the walk corners. Conclusion Concerns have been expressed by the Building Department overproper transfer of fat farces in the garage, We are requiring tf�e abQveyspecified structural treatment to era adequate structural performance require for phis structure. provide the Your rev- iew and approval of the same will be most appreciated. contact us if you have any further questions or concerns. Sincerely, The Dyer Group, LLC Winston R. Dyer, PE Idaho Structure! Engineer# 4315 Can f J. B. Kay Construction As always, please feed free to THE DYER GROUP, LLC * 3 7 0 N 2ND EASE, IT 153 a EXBURG, IIS y 1607 208+ N1E* 1.X25 (TOLL FRES) a 208.656.880