Loading...
HomeMy WebLinkAboutCHECKLIST - 05-00303 - 732 Centennial Loop - Madison School District%I 411A W ^19%, RESIDENTIAL PLAN CHECKLIST (2--003 International Residential Code) Date: $ -26 -�S Project. AlpbI60r,) ��.}fla� Zoning:OtZ— Building P Job Address: �3Z ��N � . Number of Stories: k Basement" Ye) Nv / Fi A.n � �1_(p Ftoor Area (sf) 1 7 1 (o finished - - unfinished, '7c5O garage Valua tion.- $ (101 3h0 Permit Fee: 7Z P I K Fixtures. Plan Check Fee:., $ -0 1 -1 The following comments based on the 2003 edition of me #nfernationa1 Residential Code should be resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and specifications peel ications does not permit the violation of any section of the 1ntematiana{ Residential Code or an fedez�.l, state or local regulations. Y PLAN CHECK A. Plans &/ To Scale /Legible, Plot Plan Y 1N�F'lood Plain 'Floor /Foundation Plan Oel VO Section shoving construction details All Building Elevations Design Criteria (shall be. identified on plans as Wind 85 m.p.h., Snow ,4russ Calculation Sheets &°�'Ioor Joist Details ��vt�[� � j�piL 0 Mechanical Design .Energy Calculations (R,320 & Ch 11) B. Zoning (cheek one - in some cases LDR2 and MDR may apply) LDR ✓LDR 1 Lot area — LDR- 12,000 sq. ft. min. (width 80 ft. min) (width60 ft. mion.).(LDRI duplex - 10,000 sq. ft. min.) 35 1b. Per sq ft.) & LDRl- 8,000 sq. ft. min C. Use Single Family Duplex (LDRI only - Conditional use emmftt? D. Set Backs (taken from eaves) �Front set back (32 ft. From curb) Note: 60% min of front yard green Rear set back (LDR 25 ft. & LDRI 20 ft.) ✓Sides set backs (6" for every ft. of building height with LDR - 73min., & LDRI - 6'min.) t,/Building-Height (maximum 30 ft.) E. Footings lw� Proper Size has per Table 403. 1, debar (2-#4 coniinuc�us} use 1500 psf unless sal"I type is known, Table 401.4.1 for soil bearing) Footing Depth (36" below finished grads and 12" below undisturbed soil; 18"" to top of slab -- interior} Fudation Foundation wails wl rebar (city ordinance) X1.12" Anchor Bolts with 2"x 2"x 3116" square washers (incl. inferior beariiagwalls).R403.1.6.1 Wl"'Foundatxon Drainage (foundations on sift. soil shall be designed per R405) 'Damp proof ng/Waterproofing to finish grade. R406.1 (fnd. extends 6" min above grace R444.1.6) Crawl space access of 18" x 24" min. R4083(may differ if meth appliance is in crawl space M 130�.1.4} Crawl space within 3' Ventilation/Insulation =1 sf vent per 15Q sf.(with moisture barrier of each corner (insulate walls yens to inside of home) R408-2 xrading slope away from house. R401.3 G. Frame w""Seismie Hold Downs'and Braced Wall Panels (R602.10) Floors joists sized as per R502.3, Wood I- aists sued per manufr. wl--�Joists Under Load Bearing Partitions shall be doubled, R542.4 er 1500s Girders sized per R502.5 or per manuft. Tables for engineered products Cantilevers (coinply with X502,3.3 or manuft instruction) . ft.) and ig 'Floor Sheathing (3/4-111 min forjoists 24" oc & 5/8"' for joists 16'" oc) 8503.1 Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3 (5) 8602.3 /Headers in Bearin�y Wall shall be designed as per Tables Sfl�.S(1 c�2 RdU2.7 .)Roof Trusses (designed according to R802.10.1) 35 Snow and 90 mph winds (Local Conditions) ✓Rafter and Truss tie -downs. (R-802.10.5) V'40A0ttI'c Access 22" x 3D" min. opening (R807) H. Exterior hovering Masonry and stucco shall have weather resistive barrier over exterior sheathing R7.03..2 & 70309-01 I. Roof Covering and Ventilation �Roof Ventilation as per R806 Asphalt Shingles (slope>.2:12) w/ice protection. (Other type: to comply w/ R905 a J. Firewalls Garage/House drywall separation (pxoteci ��t. walls & beams supporting habitable spaced R309.2 �i)oor from garage to Douse (1 318" solid mood or steel door, or 20 min. -fire-rated door) R309.1 �wo Family Dwelling Separation (1 lir fire separation) Supporting structure also rated. R317.1 fY D4;in homes & Townhouses (2- hr separation & 4' overturn protection or parapets 8317.2 One lu walls Parallel to and Within 3 ft of property dine wl NC) openings . 8342 �- Penetrations in previous 3 Mems to comply with R317.3 K. General Requirements House Numbers R321 �Half Operiable 3 sf -Mndow or Mech. Ventilation in bathrooms., water closets, and similar rooms. R303.3 .-loeoe"'Interior and exterior stair illumination shall comply with R3016. Bathroom Fixture clearances comply with Figure R307.2 �One room at feast 120 sf ; Other habitable rooms 70.sf. min wl a min. dimensian of 7 ft_ R304 *meas w/ sloped ceilings less than 5ft in heizht & furred ceilings less, than 7 ft TV- VnT ,-­�n A„ *50Yo or more of the required area must be at leash ?ft highin roams w/sloped ceiling "tV /Egress clearance -from window vF°e11s under canfilevered floors. R310.2 /Glazing at Hazardous Locations R348 Emergency egress 'in all sleeping rooms and basements with habitable space R310 X One required Exit Door shall comply with R311.4 �Landings at top and bottom of stairways 831.1.5.4, and each side of each exterior door. R311,4.3 _/Stair Rise 1 Run (7 3/41t mix. rise & 10" rn.zn. tread, nosing req'd if X1. 1") Stair Width (36" min), Stairway Headroom (68" min.) Handrails (34"to 38" above stair nosing){R311.5) [�A Special conditions for circular, spiral and ender stairways and bulkhead enclosures X311.5.5 tairway Projection (enclosed accessible space under stairs shill be covered with 1/2" dry -w -all) R3112.2 -Guardrails complying with 8312 11andrails complying with R311.5.6 vpe"' Smoke Alarms (each bedroom and common area and one on each level) (R 313) L. Energy Zphomes with glazing < 15% of gross area of ext. Nvalis (Townhouses < 25%) to comply wl *Otherwise shall meet requiremenls c�, f' -[ECC for respective building tyke. N1101.2 ✓Vapa�r retarder ora warm in winter side �f walls, eei��ng and floors 8318 ,/Water Heater heat traps IECC 504.7 ✓ Duct sealing and insulation N1103.3&4 or, IECC 503.3.3.3, 503.3.3.4.3 Plans match quantifies & values on a "passing" REScheck compliance report . N M. Mechanical v/o'�Gas appliances not in bed -rooms., bathrooms, toilet roozns, or storage closets G2446.2 Chapter 1 1. Room access 24"' min widthlAttic access clear apening 2�Dx3 �lUnder floor .r.o. 2200. M1305 ,le"'Potential vent/connector offset > 75°/a of total Leight (Exception provided by G242$) G2427&6.94 Dryer Vent length 25' max wl S' trans'tion (-S' per 90 deg tux -ns) M1501.3 Gas "point of delivery" and material used to determi ne pipe sizing. G2413