HomeMy WebLinkAboutINFRASTRUCTURE PLAN - 20-00566 - 220, 224, 228 N 3rd W - Quicksilver Subdivision Rezone to MDR2-Reviewed-Corrections-RequiredAuthor Name Author Email Author Phone No.:
Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165
Description : SITE PLAN - QuickSilver - 220, 224 & 228 N 3rd W
Address : 220 N 3rd W, 1
Application Type :
Document Filename : 20-00566 - SITE PLAN - 220, 224, 228 N 3rd W - Quicksilver Subdivision Rezone to MDR2.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
SITE PLAN Free text Alan Parkinson : P&Z Open 1 Not enough information to review. Dimensions of buildings,
parking stalls, road widths, etc. are needed.
# 20-00410
Civil Site Plan
Report Date: 16-07-2020
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
N89° 44' 10"E
430.00'
S0
°
1
5
'
0
3
"
E
16
5
.
0
3
'
S89° 43' 48"W
429.99'
N0
°
1
5
'
0
6
"
W
16
5
.
0
8
'
N89° 44' 10"E
430.00'
S0
°
1
5
'
0
3
"
E
16
5
.
0
3
'
S89° 43' 48"W
429.99'
N0
°
1
5
'
0
6
"
W
16
5
.
0
8
'
SITE PLAN FOR:
MORGAN PETERSON TOWNHOMES
FIRE CODE NOTE:
D103.6.1 ROADS 20 TO 26 FEET IN WIDTH.
FIRE LANE SIGNS AS SPECIFIED IN SECTION D103.6 SHALL
BE POSTED ON BOTH SIDES OF THE FIRE APPARATUS ACCESS
ROADS THAT ARE 20 26 FEET WIDE (6096 TO 7925 MM)
SURVEY NOTE:
This site plan conforms to an actual survey that was performed on the
ground by a licensed land surveyor in and for the State of Idaho. It is
the owner’s responsibility to construct all structures shown on this site
plan in accordance with said survey.
AREA: 70,973 (1.629 ACRES)
LOTS: 7 LOTS
BUILDINGS: 12 (48 UNITS)
BUILDINGS PER LOT: 1.71
UNITS/ACRE: 29.46
SITE INFORMATION:
GENERAL NOTE:
ALL PUBLIC IMPROVEMENTS SHALL BE CONSTRUCTED
IN ACCORDANCE WITH THE CURRENT CITY OF IDAHO
FALLS ENGINEERING STANDARD SPECIFICATIONS AND
STANDARD DRAWINGS.
APPROVED BY ________________________DATE:____________
City of REXBURG
LEGEND
PROPOSED CATCH BASIN
PROPOSED FIRE HYDRANT
EXIST. LIGHT POLE
PROPOSED STREET LIGHT
PROPOSED WATER VALVE
EXIST. SANITARY SEWER MANHOLE
EXIST. CURB & GUTTER
PROPERTY LINE
GRADE BREAK
SAW CUT
STREET RIGHT-OF-WAY (ROW)
EASEMENT LINE
EXIST. FENCE LINE
PROPOSED UNDERGROUND POWER
EXIST. SANITARY SEWER LINE
PROPOSED SANITARY SEWER LINE
PROPOSED WATER LINE
EXIST. WATERLINE
PROPOSED SANITARY SEWER SERVICE
PPROPOSED WATER SERVICE
EXISTING OVERHEAD POWER
EXISTING OVERHEAD TELEPHONE
EXISTING GAS SERVICE
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED CONCRETE SIDEWALK
PROPOSED ASPHALT
PROPOSED LANDSCAPING
PROPOSED BUILDINGS
EXISTING ASPHALT TO BE PROTECTED
PROPOSED STORM DRAIN MANHOLE
PROPOSED CURB & GUTTER
PROPOSED STORM DRAINLINE
EXIST. POWER POLE
PROPOSED SANITARY SEWER MANHOLE
CHECK BY
SHEETS
DRAWN BY
JOB NO:
DATE:
OF
SHEET
BDJTKP
SH
E
E
T
N
A
M
E
:
PR
O
J
E
C
T
:
LO
C
A
T
I
O
N
:
2020-060
DATE:DATE: July 14, 2020
DA
T
E
RE
V
I
S
I
O
N
S
CL
I
E
N
T
:
Th
e
C
i
v
i
l
C
o
n
n
e
c
t
i
o
n
11
5
0
H
o
l
l
i
p
a
r
k
D
r
.
I
d
a
h
o
F
a
l
l
s
,
I
D
8
3
4
0
1
20
8
.
6
8
1
.
8
5
9
0
PRELIMINARY FOR
REVIEW ONLY
1
1
MO
R
G
A
N
P
E
T
E
R
S
O
N
T
O
W
N
H
O
M
E
S
SI
T
E
P
L
A
N
RE
X
B
U
R
G
,
I
D
TOTAL STORAGE REQUIRED= 7,984 cu ft
PROPOSED STORAGE= 8,000 cu ft
STORM WATER REQUIREMENTS
TOTAL REQUIRED (20%)= 14,195 sq ft
PROPOSED LANDSCAPE= 28,363 sq ft (40%)
LANDSCAPE REQUIREMENTS
Not enough information to review. Dimensions of