HomeMy WebLinkAboutPLANS - 21-00972 - 643 Mill Stream St - Solar PanelsWIRING S H A L L N O T B E I N S T A L L E D W I T H I N 1 0 " O F R O O F D E C K I N G E X C E P T W H E R E DIRECTLY B E L O W T H E R O O F S U R F A C E C O V E R E D B Y P V M O D U L E S A N D / O R E Q U I P M E N T M O D U L E A N D I N V E R T E R ( S ) PLEASE R E F E R T O L A B E L P L A N F O R W A R N I N G S P E R N E C 6 9 0 & I R C 2 0 1 8 SCOPE OF WORKWiring m u s t b e p r o p e r l y s u p p o r t e d b y d e v i c e s o r m e c h a n i c a l m e a n s designed a n d l i s t e d f o r s u c h u s e . W i r i n g m u s t b e p e r m a n e n t l y a n d complet e l y h e l d o f f o f t h e r o o f s u r f a c e . N E C 1 1 0 N O T E S NAPCEP HOLDER & CERT #UT. CONTRACTORS LICENSE # & TYPEAPPLICABLE CODES Michael Allen - 032611-4Michael Telford - 092411-142 #7426030.5501Class LRF, B100, S200, S2022018 International Building Code (IBC)SHEET INDEXTITLE SHEETSITE PLANELECTRICAL LINE DIAGRAMEQUIPMENT LABELS ARRAY DETAILSINSTALLATION/METER DETAILMODULE CUT SHEETINVERTER CUT SHEETRACKING SPEC PV01PV02PV03PV04PV05PV06 E n p h a s e M i c r o - I n v e r t e r s ( I Q 7 + ) 2017 National Electric Code (NEC)(24)(24)SYSTEM I S " R A P I D S H U T D O W N " C O M P L I A N T R E C 3 6 5 W STREET VIEW V I C I N I T Y M A P Total Area of Array(s): 432ft²Pass Through Boxes Mounted Flush on Installation Surface (27,34º)System Size: 8.76kWMeter Upgrade: NO Standard Asphalt Shingle RoofArray(s) Azimuth: 180, 270ºAnchored on 48" Centers using UL Listed Snap N Rack UR-40 System2018 International Residential Code (IRC) S H E E T # S C A L E : INTERMOUNTAIN WIND & SOLAR 1953 WEST 2425 SOUTH WOODS CROSS, UT, 84087 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2021-729-ID 8.76kW - (24) Modules Rexburg 11/09/2021 Designer Revision Jie Sheng Li 643 Mill Stream St Rexburg, ID 83440 T.Schoen M i c h a e l T e l f o r d - 0 9 2 4 1 1 - 1 4 2 P V 0 1 N . T . S 9 0 1 2 0 1 5 0 1 8 0 2 1 0 2 4 0 2 7 0 3 0 0 3 3 0 0 3 0 6 0 W E S N 8 0 7 0 5 0 4 O 2 0 1 0 3 5 0 3 2 0 3 1 0 2 9 0 2 8 0 2 6 0 2 5 0 2 3 0 2 2 0 2 0 0 1 9 0 1 7 0 1 6 0 1 4 0 1 3 0 1 1 0 1 0 0 3 4 0 A Z I M U T H IFC FIRE C O D E S E T B A C K S 3' and 18" 1 2 ' - 3 " E X T E R I O R M E T E R W A L L M E T E R M A I N 2 0 0 A 2 4 0 V 6 0 A P V D I S C O N N E C T 8 0 A E N P H A S E A C C O M B I N E R I N T E R I O R M E T E R W A L L H O M E L O A D P A N E L 2 0 0 A 2 4 0 V 2 P 4 0 A P V B R E A K E R WIRING S H A L L N O T B E I N S T A L L E D W I T H I N 1 0 " O F R O O F D E C K I N G E X C E P T W H E R E DIRECTLY B E L O W T H E R O O F S U R F A C E C O V E R E D B Y P V M O D U L E S A N D / O R E Q U I P M E N T M O D U L E A N D I N V E R T E R ( S ) PLEASE R E F E R T O L A B E L P L A N F O R W A R N I N G S P E R N E C 6 9 0 & I R C 2 0 1 8 SCOPE OF WORKWiring m u s t b e p r o p e r l y s u p p o r t e d b y d e v i c e s o r m e c h a n i c a l m e a n s designed a n d l i s t e d f o r s u c h u s e . W i r i n g m u s t b e p e r m a n e n t l y a n d complet e l y h e l d o f f o f t h e r o o f s u r f a c e . N E C 1 1 0 N O T E S E n p h a s e M i c r o - I n v e r t e r s ( I Q 7 + ) (24)(24)SYSTEM I S " R A P I D S H U T D O W N " C O M P L I A N T R E C 3 6 5 W Total Area of Array(s): 432ft²Pass Through Boxes Mounted Flush on Installation Surface (27,34º)System Size: 8.76kWMeter Upgrade: NO Standard Asphalt Shingle RoofArray(s) Azimuth: 180, 270ºAnchored on 48" Centers using UL Listed Snap N Rack UR-40 System S H E E T # S C A L E : INTERMOUNTAIN WIND & SOLAR 1953 WEST 2425 SOUTH WOODS CROSS, UT, 84087 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2021-729-ID 8.76kW - (24) Modules Rexburg 11/09/2021 Designer Revision Jie Sheng Li 643 Mill Stream St Rexburg, ID 83440 T.Schoen M i c h a e l T e l f o r d - 0 9 2 4 1 1 - 1 4 2 P V 0 2 1 1 6 " = 1 ' EGC BONDED TO ALL EQUIPMENTSIZED ACCORDING TO NEC 690 AND NEC 250 INVERT E R S P E C I F I C A T I O N S MANUFACT U R E R E n p h a s e E n e r g y MODEL I Q 7 P L U S - 7 2 - 2 - U S MAX DC INPUT V O L T A G E 6 0 V MAX OUTPUT P O W E R 2 9 0 W NOMINAL AC OUTP U T V O L T A G E 2 4 0 V NOMINAL AC OUTP U T C U R R E N T 1 . 2 1 A MAX FUSE (O C P D ) 2 0 A M A I N M E T E R U T I L I T Y E X I S T I N G G R O U N D I N G C O N D U C T O R # 6 6 8 5 7 4 4 7 2 0 0 A M A I N I N T E R C O N N E C T I O N P C C M A D E I N E X I S T I N G I N T E R I O R 2 4 0 V A C , 2 0 0 A A C 1 P H A S E H O M E L O A D P A N E L W I T H L O A D S I D E C O N N E C T I O N U S I N G ( 1 ) 4 0 A A C 2 P O L E S O L A R B R E A K E R R A T E D F O R B A C K F E E D . T H I S C O N N E C T I O N S H A L L B E M A D E I N C O N F O R M A N C E W I T H 2 0 1 7 N E C 7 0 5 . 1 2 . B R E A K E R T O B E L O C A T E D O N E M P T Y S P A C E O N 2 0 0 A A C B U S B A R W I T H 2 0 0 A A C M A I N B R E A K E R . ( ( 2 0 0 A A C X 1 . 2 ) - 2 0 0 A A C = 4 0 A A C A L L O W A B L E S O L A R ) . PV MODULE SPECIFICATIONSMANUFACTURERRECMODEL365WMAX POWER-POINT CURRENT (Imp)9.60 AMAX POWER-POINT VOLTAGE (Vmp)38.0 VOPEN CIRCUIT VOLTAGE (Voc)44.3 VSHORT CIRCUIT CURRENT (Isc)10.26 AMAX SERIES FUSE (OCPD)25 AMAX POWER (Pmax)365 WMAX VOLTAGE (Vdc)1000 V 6 0 A 1 2 0 / 2 4 0 V N O N - F U S E D D I S C O N N E C T #6 BARE COPPER EG S N A P N R A C K M O U N T I N G E N P H A S E M I C R O - I N V E R T E R ( I Q - 7 + ) R E C 3 6 5 W (1)3/ 4" EMT(6)#10THWN-2(1)#10THWN-2 EG ( 1 ) 3 / 4 " E M T ( 3 ) # 8 T H W N - 2 ( 1 ) # 1 0 T H W N - 2 E G E X I S T I N G ( 1 ) 2 " E M T ( 3 ) # 4 / 0 T H W N - 2 A L ( 1 ) # 6 T H W N - 2 E G FREE AIR(3) ENPHASE Q - CABLE(3)#6 BARE COPPER EG(3) 3/ 4" EMT(2)#10THWN-2(1)#10THWN-2 EG ( 1 O F 1 ) W I T H I N 1 0 ' O F M A I N M E T E R E N P H A S E Q - C A B L E NEMA 4J-BOX 15" x 2.5" x 15"SOLADECKCOMBINERBOX6"x6"x3" E N P H A S E A C I Q C O M B I N E R 3 2 0 A - 2 P 2 0 A - 2 P 8 0 A 1 2 0 / 2 4 0 V 2 0 A - 2 P E N V O Y M O N I T O R I N G ELECTRICAL NOTES: 1. ALL COMPONENTS ARE GROUNDED PER NEC 2017 CODE 2. INTERCONNECTION METHOD COMPLIES WITH 690 3. ALL WIRES WILL BE RATED THHN/THWN-2 4. ALL INTERCONNECTION WILL COMPLY WITH 705.12 P L E A S E R E F E R T O P V 0 6 F O R A D D I T I O N A L I N T E R C O N N E C T I O N P H O T O S * ACTUAL DC WIRING AN D / O R C O N D U I T B O D Y T O BE DETERMINED IN FIE L D . M A Y B E R E P L A C E D B Y 1 2 - 2 M C C A B L E . * ARRAY COMPLIES WIT H N E C 6 9 0 R A P I D S H U T D O W N R U L E ILOCATION: RAPID SHUTDOWN COMPLIANCE DEVICE**ALL PHOTOVOLTAIC (D C ) C I R C U I T S WILL BE LABELED E V E R Y 1 0 ' 690 F A C T O R Y I N S T A L L E D 2 P M O N I T O R I N G B R E A K E R ( 1 5 A o r 1 0 A ) 2 9 . 1 A 2 4 0 V P H O T O V O L T A I C A C O U T P U T L A B E L A C O U T P U T C U R R E N T N O M I N A L A C V O L T A G E 15" x 2.5" x 15"SOLADECKCOMBINERBOX15" x 2.5" x 15"SOLADECKCOMBINERBOX E N P H A S E A C I Q C O M B I N E R 3 8 0 A 1 2 0 / 2 4 0 V 4 0 A - 2 P 2 0 0 A ( 1 ) 3 / 4 " E M T ( 3 ) # 8 T H W N - 2 ( 1 ) # 1 0 T H W N - 2 E G I S H E E T # S C A L E : INTERMOUNTAIN WIND & SOLAR 1953 WEST 2425 SOUTH WOODS CROSS, UT, 84087 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2021-729-ID 8.76kW - (24) Modules Rexburg 11/09/2021 Designer Revision Jie Sheng Li 643 Mill Stream St Rexburg, ID 83440 T.Schoen M i c h a e l T e l f o r d - 0 9 2 4 1 1 - 1 4 2 P V 0 3 N . T . S P h o t o v o l t a i c A r r a y C i r c u i t D e t a i l I n v e r t e r S o u r c e C i r c u i t # o f M o d s I Q 7 + 1 1 2 2 1 0 3 2 4 5 6 ( 1 2 ) M O D U L E C I R C U I T I N P U T 1 TYP. MID-CLAMP T Y P . L - F O O T TYP. 24" SPAN TRUSSES T Y P . S O L A R P A N E L T Y P . E N D - C L A M P MAX SPAN BETWEEN L-FEET 4'120 MPH RATED STAGGERED L-FEET4' SPAN MAX @ 0°-60° 80PSF UP TO 140 MPH TYP. PANEL OVER HANGSNAPNRACK: 9"-16"INVISIMOUNT: 2"-16"TYP. RAIL CANTILEVERSNAPNRACK &INVISIMOUNT: 16-1/4" = SOLADECK JUNCTION BOX ( 1 0 ) M O D U L E C I R C U I T I N P U T 2 ( 2 ) M O D U L E C I R C U I T I N P U T 3 S H E E T # S C A L E : INTERMOUNTAIN WIND & SOLAR 1953 WEST 2425 SOUTH WOODS CROSS, UT, 84087 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2021-729-ID 8.76kW - (24) Modules Rexburg 11/09/2021 Designer Revision Jie Sheng Li 643 Mill Stream St Rexburg, ID 83440 T.Schoen M i c h a e l T e l f o r d - 0 9 2 4 1 1 - 1 4 2 P V 0 4 N . T . S MICRO INVERTER SYS T E M S I G N A G E *All signage must be permanently attached and be able to withstand the env i r o n m e n t they are installed. Signage also cannot be hand-written. NEC 110.A sign is required at the service panelstating that the home has a solar PVsystem as an additionalpower source.This sign is required to be located next tothe PV backfed breaker(s) ONLY if the120% allowance ofNEC 705.12PV SYSTEM:AC Current = 29.1AAC Volts = 240VThis sign is required to be located at theback-fed panelboard.This sign must be reflective and is requiredto be located next to the disconnect switchwhich activates rapid shutdown. T h i s s i g n i s r e q u i r e d t o b e l o c a t e d a t t h e b a c k f e d p a n e l b o a r d . S O L A R M E T E R P A R A L L E L G E N E R A T I O N O N S I T E * P L A C A R D R E Q U I R E D B Y U T I L I T Y * P L A C A R D R E Q U I R E D B Y U T I L I T Y M A N U A L D I S C O N N E C T F O R P A R A L L E L G E N E R A T I O N WITHIN 10' OFMETERAC DISCONNECT(1 of 1) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNINGINVERTER OUTPUT CONNECTION, DO NOTRELOCATE THIS OVERCURRENT DEVICE. W A R N I N G E L E C T R I C A L S H O C K H A Z A R D D O N O T T O U C H T E R M I N A L S T E R M I N A L S O N B O T H L I N E A N D L O A D S I D E S M A Y B E E N E R G I Z E D I N T H E O P E N P O S I T I O N . T h i s s i g n t o b e l o c a t e d o n t h e o u t s i d e o f , a n d w i t h i n 3 ’ o f t h e s e r v i c e e q u i p m e n t . R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M M u s t b e p r o v i d e d n e x t t o t h e r a p i d s h u t d o w n d i s c o n n e c t f o r t h i s s y s t e m . S H E E T # S C A L E : INTERMOUNTAIN WIND & SOLAR 1953 WEST 2425 SOUTH WOODS CROSS, UT, 84087 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2021-729-ID 8.76kW - (24) Modules Rexburg 11/09/2021 Designer Revision Jie Sheng Li 643 Mill Stream St Rexburg, ID 83440 T.Schoen M i c h a e l T e l f o r d - 0 9 2 4 1 1 - 1 4 2 P V 0 5 N . T . S METER WALL H O M E L O A D P A N E L A T T I C D E T A I L S H E E T # S C A L E : INTERMOUNTAIN WIND & SOLAR 1953 WEST 2425 SOUTH WOODS CROSS, UT, 84087 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2021-729-ID 8.76kW - (24) Modules Rexburg 11/09/2021 Designer Revision Jie Sheng Li 643 Mill Stream St Rexburg, ID 83440 T.Schoen M i c h a e l T e l f o r d - 0 9 2 4 1 1 - 1 4 2 P V 0 6 N . T . S