Loading...
HomeMy WebLinkAboutPLANS GREETING DESK REDLINED - 21-00250 - BYUI Manwaring Center Activities & Involvement - RemodelAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : BYUI Manwaring Center Academic Advising - RemodelAddress : 479 S Center StRecord Type : Commercial - RemodelDocument Filename : ASI-004 New Greeting Desk - Revised.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00765 Commercial - Remodel Glass and Glazing meets the requirements of IBC Chapter 24 Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Page 1 of 1 360 West Aspen Ave Salt Lake City, Utah 84101 method-studio.com 801 532 4422 Architect’s Supplemental Instructions PROJECT: (name and address) CONTRACT INFORMATION: ASI INFORMATION:  BYU Idaho Engineering Technology Center (ETC) Rexburg, ID Contact For: ASI Number: 004 Date: Date: 8/4/21 OWNER: (name and address) ARCHITECT: (name and address) CONTRACTOR: (name and address) BYU Idaho BYU Idaho Project #. 12175 Method Studio 160 West 2nd North, ste. 201 Rexburg, ID 83440 Okland Construction 101 S Capitol BLVD Suite 504 Boise, ID 83702  The Contractor shall carry out the Work in accordance with the following supplemental instructions without change in Contract Sum or Contract Time. Proceeding with the work in accordance with these instructions indicates your acknowledgment that there will be no change in the Contract Sum or Contract Time. (Insert a detailed description of the Architect’s supplemental instructions and, if applicable, attach or reference specific exhibits.) Per BYUI's request, please add a greeting desk in room 120. Attached are architectural and electrical drawings for clarification. Please provide a submittal for this casework, for BYUI and the architect to review. Power will need to be provided to this desk. Please demo the floor as needed to provide power. Thanks! ISSUED BY THE ARCHITECT: Method Studio ARCHITECT (Firm name) SIGNATURE Kyler Hokanson PRINTED NAME AND TITLE 8/4/21 DATE REF. A A B B G G C C D D E E F F H H J J K K L L M M N N P P Q Q 2 2 3 3 4 4 6 6 7 7 8 8 10 10 11 11 12 12 1 1 9 9 5 5 Seminar Room 117A 111 SF Office 129M 114 SF Office 129L Storage 129K 101 SF Office 129J 104 SF Office 129H 105 SF Office 129G Storage 129F 123 SF Office 129E 99 SF Office 129D 94 SF Office 129C 85 SF Office 129B Kitchen 118A Chair Storage 117C Mentoring 124A Mentoring 124B Mentoring 124C Mentoring 124D Mentoring 124E Mentoring 124F 203 SF Training 126 291 SF Collaboration 120A 1089 SF Student Support/Mentor Hub 127 Info 120C Greeting 120 Digital Activity Area 120B Campus Recreation 129 Storage 118B Lobby 129A Corridor 32 Corridor 1J Corridor 1T Corridor 1D AE421 D4 E1 D3 AE422 D4 E1 AE422 E2 AE421E2 AE421 C1 B4 B1 C4 AE422 A1 AE422 A4 AE421A1 A2 AE422 C2 C3 C4 C1 B2 AE401 A1 AE401 C1 AE401 D1 D2 AE422 E4 124A 124B 124C 124D 124E 124F 127A127B 129 129B 129C 129D 129E 129F 129M 129L 129J129H129G 129K 118B 117C 125B125A D1 Office 125A Office 125B Storage 129N 120B 120A 117B SF 1 SF 2 SF3 SF 4 SF5SF6SF7 117A 129P D1 B1 AE510 129A 127C PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3bPS3b PS3b PS3bPS3bPS3b PS3b PS3b PS3e PS3b PS3e PS3b PS3b PS3b PS3b PS3b PS3b PS3b PS3x PS3b PS3b PS3b PS6bPS6b PS3ePS3e PS3b PS3e PS3e 129N PS3b PS6bPS6b SF 9 PS3x PS3xPS3xPS3x PS3x PS3x PS3b PS3x Storage 125C 02.06 10.05 10.06 10.06 26.0126.01 26.0126.01 10.02 26.01 26.01 26.01 26.01 26.01 26.01 02.0702.0702.07 11.03 AE422 E3 PS3x SF 8 000000 PS2e AE421 A4 E4 3' - 0 " SEE ELECTRICAL DRAWINGS FOR DATA & OUTLET LOCATION, COORDINATE WITH BYUI. NEW ATM LOCATION. RE: ELECTRICAL. 14' - 0" 11' - 0" 8' - 3 1/4" 1' - 4 " AE421B5 EQ EQ 3' - 0" AE421 A5 8' - 6 3 / 4 " 10 ' - 0 " 26.01 SF 1 0 231 SF Storage 126B REPLACE WALL AND INFILL DOORWAY 126A REPLACE DOOR AND DOOR FRAME. USE THE SAME HARDWARE SET AS 127A WITHOUT CARD READER (HARDWARE SET #07, SEE UPDATED DOOR SCHEDULE). DEAD BOLT THUMB TURN. KEY ON STUDENT SUPPORT/MENTORING HUB SIDE 126B 7 EXISTING WALLS TO REMAIN, REFER TO DEMOLITION PLANS FOR REMOVAL OF EXISTING WALLS LEGEND 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 AE101 Level 1 - Floor Plan 21.0105 04/16/2021 101 E Viking St Drive Rexburg, ID 83460 BYUI MC ACTIVITIES & INVOLVEMENT CENTER REMODEL Bid Set 1/8" = 1'-0"A1 Level 1 - Floor Plan 1 Addendum #01 04/29/21 2 ASI 001 06/02/21 3 RFI 008 06/23/21 5 RFI 017 07/05/21 6 ASI 003 8/3/21 7 ASI 004 8/4/21 KEYED NOTES 000000 DIVISION 00 02.06 EXISTING STOREFRONT TO REMAIN 02.07 EXISTING SODA RACK AND APPLIANCES, CONTRACTOR TO COORDINATE WITH BYUI & RESTAURANT 10.02 MARKER BOARD, MB-01; RE: FINISH SCHEDULE 10.03 ADJUSTABLE SHELVING, OFOI 10.05 FOLDING DOOR 10.06 OVERHEAD COIL GRILLE DOOR, ELECTRIC. RE: DOOR SCHEDULE 11.03 EXISTING VENDING MACHINES, CONTRACTOR TO COORDINATE WITH BYUI 26.01 TELEVISION MONITOR, OFCI GENERAL NOTES - FLOOR PLAN 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE DRAWINGS 3 ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED 4 ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED UNLESS NOTED OTHERWISE 5 SEE SHEET GI003 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT. 6 COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OFOI, WITH OWNER 7 SEE SHEET SERIES AE500 FOR WALL AND ASSEMBLY TYPES 8 SEE SHEET SERIES AE600 FOR DOOR & WINDOW TYPES 9 ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT 10 SEE WALL SECTION SHEET SERIES AE310 FOR WALL TYPES AT SPECIFIED LOCATION 11 SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS 12 SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION 13 BUILDING SIGNAGE WILL BE OFOI 30" TO 34" TALL TABLE WITH CHAIRS WILL BE PROVIDED IN THIS AREA TO SATISFY THE 30% WORKSURFACE REQUIRED FOR ACCESSIBILITY IN FOREGROUNDIN FOREGROUND 09.01 09.04 TYP TYP 127B 127A A4 AE531 127C 09.18 09.01 09.04 TYP TYP IN FOREGROUND 09.01 09.01 09.04 AE510 A4 30' - 0 111/256" ALIGNS WITH CEILING OPENING 12' - 0"14' - 6" 09.01 09.04 IN FOREGROUND 09.16 CL 2' - 6 3/8" 4' - 1 0 " 09.13 VINYL WALL GRAPHIC LEVEL 5 FINISH IN FOREGROUND 09.01 129N CL 26.01 09.23 IN BACKGROUND 09.01 09.13 TYP A3 AE531 129 129A 09.18 09.01 09.04 09.03 09.13 RECESSED FOR FOLDING DOOR 09.03 09.13 117C 10.05 EQ EQ 5' - 4 1 / 2 " 09.03 09.13 26.01 CL CL 09.03 09.22 09.03 TY P 4' - 1 0 " 17' - 11 1/2"9' - 0" 26.01 26.01 09.03 09.13 10.05 AE510 A1 09.1609.16 09.23 09.23 09.0502.01 STOREFRONT EXISTING CONTINUOUS WALL GRAPHIC 5' - 5 " 26.01 EQEQ RECESSED 09.03 09.22 02.0402.04 02.01 FILLER 1 5/8"4' - 0"4' - 0"FINISHED END PANEL 1 5/8" 2' - 1 0 " 102 102 12.01 06.0109.15 D2 AE510 E6 AE510 OPEN TO BEYOND 09.07 42 " 1 1/2" 1 3/8" 45 1/8"24"45 1/8" 1 3/8" 1 1/2" E6 AE510 OPEN TO BEYOND 06.03 12.01 06.01 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 AE421 Interior Elevations 21.0105 04/16/2021 101 E Viking St Drive Rexburg, ID 83460 BYUI MC ACTIVITIES & INVOLVEMENT CENTER REMODEL Bid Set 1 Addendum #01 04/29/21 2 ASI 001 06/02/21 6 ASI 003 8/3/21 7 ASI 004 8/4/21 1/4" = 1'-0"B1 Student Support/Mentor Hub 127 - North 1/4" = 1'-0"B4 Student Support/Mentor Hub 127 - East 1/4" = 1'-0"C1 Student Support/Mentor Hub 127 - South 1/4" = 1'-0"C4 Student Support/Mentor Hub 127 - West 1/4" = 1'-0"A1 Lobby 129A - West 1/4" = 1'-0"A2 Lobby 129A - North 1/4" = 1'-0"D3 Seminar Room 117A - East 1/4" = 1'-0"D4 Seminar Room 117A - South 1/4" = 1'-0"E1 Seminar Room 117A - West GENERAL NOTES - INT... 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE DRAWINGS 3 SEE SHEET GI003 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT. 4 UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH 5 UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYP. 6 ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE MOUNTED HORIZONTALLY 7 PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8 PROVIDE ALUMINUM EDGE MOULDING @ ALL TILE TO H.M. DOOR TRANSITIONS 9 PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS. SEE: FINISH SCHEDULE 10 PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS. SEE: FINISH SCHEDULE 11 ALL EXPOSED STEEL COLUMNS TO BE PAINTED TO MATCH ADJACENT WALL 12 ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 13 COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. IF SHOWN IN ELEVATION, PROVIDE 4" BACKSPLASH 14 ALL WOOD WALLCOVERING GRAIN TO RUN VERTICALLY, UNLESS NOTED OTHERWISE 15 CALLED OUT RESTROOM ACCESSORIES TO BE INSTALLED AT EVERY STALL KEYED NOTES 02.01 EXISTING TILE BASE 02.04 EXISTING PAINTED WALL 06.01 PLASTIC LAMINATE; PL-01; RE: FINISH SCHEDULE 06.03 BIRCH PLYWOOD, BB, CEAR FINISH 09.01 PAINTED GYP; PNT-01; RE: FINISH SCHEDULE 09.03 PAINTED GYP; PNT-03; RE: FINISH SCHEDULE 09.04 WALL BASE; WB-01 ; RE: FINISH SCHEDULE 09.05 TILE BASE; TB-01; RE: FINISH SCHEDULE 09.07 SPECIALTY CEILING/WALL PANEL; SC-03; RE: FINISH SCHEDULE 09.13 WALL BASE; WB-02 ; RE: FINISH SCHEDULE 09.15 WALL BASE; WB-04 ; RE: FINISH SCHEDULE 09.16 WALL GRAPHIC; WC-04 ; RE: FINISH SCHEDULE 09.18 PAINTED GYP; PNT-04; RE: FINISH SCHEDULE 09.22 TILE BASE; TB-03; RE: FINISH SCHEDULE 09.23 WALL PREP FOR GRAPHIC: LEVEL 5 FINISH, ZIMSER BULLSEYE 123 PRIMER, SHERWIN WILLIAMS CASHMERE PAINT, CONTRACTOR TO FOLLOW MFR REQUIREMENTS FOR DRYING PRIOR TO GRAPHIC INSTALL 10.05 FOLDING DOOR 12.01 QUARTZ, QTZ-01 RE: FINISH SCHEDULE 26.01 TELEVISION MONITOR, OFCI 1/4" = 1'-0"E2 Corridor 1J/ Seminar Room Entry - West 1/4" = 1'-0"D1 Seminar Room 117A - North 1/4" = 1'-0"A4 Entry - Corridor 1D - North 1/4" = 1'-0"E4 Corridor 1J/ Seminar Room Entry - South 1/4" = 1'-0"A5 Greeting Desk - Exterior Elev. 1/4" = 1'-0"B5 Greeting Desk - Interior Elev. 7 TY P 4" TY P 7/ 8 " 2 " ALIGN HORIZONTAL REFERNCE LINE TEXT: AVENIR NEXT DEMI BOLD, 1/8" ACRYLIC LETTERS ADHERED TO WALL, COLOR TO BE SELECTED BY ARCHITECT FROM FULL RANGE OF COLORS 8 1 / 2 " 1' - 7 1 / 2 " 1' - 2 1/2" R E F E R N C E L I N E LOCATION PIN: 3/4" BIRCH PLYWOOD, GRADE B/BB, 13 LAYER EXPOSED PLYWOOD EDGE, ADHERED TO WALL TO BE INSTALLED AFTER WALL GRAPHIC INSTALLATION, FINAL PLACEMENT TO BE COORDINATED WITH ARCHITECT BASED ON WALL GRAPHIC IMAGE 7 0 ° 4" 6"3"4 1/2" TYPICAL PATTERN REPEAT 47 " 47 " 23 1 / 2 " 11 3 / 4 " 23 1 / 2 " 11 3 / 4 " 47 " 11 3 / 4 " 11 3 / 4 " 23 1 / 2 " 23 1 / 2 " WB-03 ACT CEILING; RE: RCP PLANS ALIGNS WITH EXPOSED CEILING 12' - 0" FINISHED FLOOR WB-01 4 1/4" 2'X4' METAL PANEL WITH TRIM , SC-03; RE: FINISH SCHEDULE T-GRID SYSTEM BACKLIGHTING; INSTALLATION PER MANUFACTURER'S INSTALLATION INSTRUCTIONS TRANSLUCENT BACKER PANEL LIGHT TRAY WITH BACKLIGHTING VERTICA CHANEL ADAPTER CLIP BASE; RE: ELEVATIONS FOR TYPE FINISHED FLOOR 1' - 0 1 / 3 2 " EXPOSED CEILING ABOVE EXISTING WALL PNT-04; RE: FINISH SCHEDULE, AT CEILING PLANE AND ABOVE EXISTING WALL FINISHED FLOOR FAUCET - RE: MECHANICAL & ELECTRICAL DRAWINGS SE E I N T E R I O R E L E V A T I O N 2CM QUARTZ COUNTERTOP: W/ EASED, SQUARE EDGE, UNDERLAYMENT AS REQ'D, RE: INTERIOR ELEVATIONS FOR FINISH TYPE, SCRIBE TIGHTLY TO WALL, SEAL SEAM WITH CLEAR SILICONE THAT WON'T YELLOW UNDERMOUNT SINK, SEE PLUMBING UNDER-SINK LAVATORY GUARD FOR ALL EXPOSED PIPING STEEL SUPPORT BRACKET, FINISH TO MATCH ADJACENT WALL COLOR/FINISH (WHERE EXPOSED) MI N C L E A R A N C E 27 " 5" 1 1 / 2 " 2 1/4" PANEL AT SINK, FIXED 3/4" PLYWOOD CORE, RE: ELEVATIONS FOR FINISH FACE BASE AS SCHEDULED; RE: ELEVATIONS FINISHED WALL; RE: ELEVATIONS FOR FINISH FACE NOMINAL 2x BLOCKING 4" BACKSPLASH IN COUNTERTOP MATERIAL, CLEAR SILICONE AT SEAMS, EASED, SQUARE EDGE Acoustic Wall Tile Legend WC-01 WC-02 WC-03 RE: FINISH SCHEDULE CARPET, RE: FINISH SCHEDULE EXISTING TILE, RE: FINISH SCHEDULE RUBBER TRANSITION, TS-02; RE: FINISH SCHEDULE RESILIENT FLOORING, RE: FINISH SCHEDULE EXISTING TILE RUBBER TRANSITION, TS-01; RE: FINISH SCHEDULE FLOOR SYSTEM, RE: HORIZ ASSEMBLIES 3 3/4" 2 1/4" EXISTING WALL SLIDING PANEL FIXED PANEL MOUNTING HARDWARE PROVIDED BY MANUFACTURER NO BLOCKING REQUIRED 4' - 2 1 / 2 " FO R M O U N T I N G H E I G H T RE : E L E V A T I O N S 4' - 0 " MOUNTING HARDWARE PROVIDED BY MANUFACTURER MOUNTING HARDWARE PROVIDED BY MANUFACTURER WALL AS SCHEDULED PROVIDE BLOCKING AS REQ'D CABINET CONSTRUCTION: 3/4" CORE MDF, INTERIOR FACED W/ WHITE MELAMINE CABINET DOOR: 3/4" MDF CORE, FINISHED WITH THERMALLY FUSED LAMINATE, SEE INTERIOR ELEVATIONS FOR TYPE. USE CORRESPONDING EDGE BANDING 14" CABINET PULL, RICHELIEU FINGER CABINET PULL; BP 98988010, ALUMINUM, 3 1/8" OV E R L A P 1 / 4 " SE E E L E V AC C E S S I B L E M I L L W O R K H E I G H T = 2 ' - 1 0 " WALL AS SCHEDULED; RE: PLAN. BACKSPLASH: 2CM QUARTZ WHERE OCCURS, RE: ELEVATION. SCRIBE COUNTERTOP TO WALL TIGHTLY, SEAL SEAM WITH CLEAR SILICONE THAT WON'T YELLOW, WHERE THERE IS NO BACKSPLASH COUNTERTOP: 2CM QUARTZ; W/ 1/2" PLYWOOD SUBSTRATE. MITER CORNERS, RE: ELEVATIONS FOR FINISH TYPE ADJUSTABLE SHELF CABINET CONSTRUCTION: 3/4" MDF CORE, FACED W/ WHITE MELAMINE. TYP, BASE CABINET DOORS / DRAWER & FILLER: 3/4" MDF CORE, THERMALLY FUSED LAMINATE, RE: INTERIOR ELEVATION FINISHED FLOOR BASE AS SCHEDULED; RE: INTERIOR ELEVATIONS ACCESSIBLE MILLWORK DEPTH = 24" MAX 1" 1/4 " 5 1 / 2 " 1/4 " 1 1 / 2 " 3" 4" CABINET PULL, RICHELIEU FINGER CABINET PULL; BP 98988010, ALUMINUM, 3 1/8" AC C E S S I B L E M I L L W O R K H E I G H T = 2 ' - 1 0 " WALL AS SCHEDULED; RE: PLAN. BACKSPLASH: 2CM QUARTZ WHERE OCCURS, RE: ELEVATION. SCRIBE COUNTERTOP TO WALL TIGHTLY, SEAL SEAM WITH CLEAR SILICONE THAT WON'T YELLOW, WHERE THERE IS NO BACKSPLASH COUNTERTOP: 2CM QUARTZ; W/ 1/2" PLYWOOD SUBSTRATE. MITER CORNERS, RE: ELEVATIONS FOR FINISH TYPE ADJUSTABLE SHELF CABINET CONSTRUCTION: 3/4" MDF CORE, FACED W/ WHITE MELAMINE. TYP, BASE CABINET DOORS & FILLER: 3/4" MDF CORE, THERMALLY FUSED LAMINATE, RE: INTERIOR ELEVATION FOR FINISH FACE FINISHED FLOOR BASE AS SCHEDULED; RE: INTERIOR ELEVATIONS 1' - 4" 11 / 3 2 " 1 1 / 2 " 1' - 0"3" 4" CABINET PULL, RICHELIEU FINGER CABINET PULL; BP 98988010, ALUMINUM, 3 1/8" CABINET LOCKS 36" 24 1 / 2 " 1/2" 6" FINISHED FLOOR OPEN CABINET; FINISHED INTERIOR, PL-01; RE: FINISH SCHEDULE PROVIDE JUNCTION BOX AT BACK OF CABINET FOR PRINTER. SEE ELECTRICAL. 15 1/4" QUARTZ COUNTERTOP AND WATERFALL EDGE WITH 3/4" PLYWOOD SUBSTRATE, FINISH FACE QTZ-01; RE: FINISH SCHEDULE 1 1 / 2 " 1 3 / 8 " EXPOSED BIRCH PLYWOOD EDGE, 13 LAYER PLY, CLEAR FINISH ARKTURA PANELS, SC-03, RE: FINISH SCHEDULE BIRCH PLYWOOD, BB, CLEAR FINISH DRAWER; PL-01; RE: FINISH SCHEDULE 1" BIRCH PLYWOOD, ENCLOSED CHANNEL FOR CONDUIT, MATCH ON BOTH SIDES FOR CONTINUITY, SIZED TO ACCOMMODATE CONDUIT, COORDINATE FINAL SIZE WITH ARCHITECT. DEMOLISH THE SLAB ON GRADE AS NEEDED TO PROVIDE POWER AND CONDUIT TO THIS DESK. SEE ELECTRICAL FOR MORE INFORMATION. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 AE510 Interior Details 21.0105 04/16/2021 101 E Viking St Drive Rexburg, ID 83460 BYUI MC ACTIVITIES & INVOLVEMENT CENTER REMODEL Bid Set 2 ASI 001 06/02/21 7 ASI 004 8/4/21 1 1/2" = 1'-0"A1 Lobby 129A - Wall Graphic Detail 1" = 1'-0"A4 Student Support/Mentor Hub 127 - Acoustic Wall Detail 1" = 1'-0"B1 Info + Digital Activity Area Ceiling and Wall Panel Detail 1 1/2" = 1'-0"C5 ADA Sink With Apron Front 12" = 1'-0"E5 Tile to Carpet Transition 12" = 1'-0"E4 Tile to Resilient Flooring 1 1/2" = 1'-0"A2 Collaboration Marker Board 1 1/2" = 1'-0"C4 Typical Upper Cabinet Detail 1 1/2" = 1'-0"C2 Typical Base Cabinet Detail 1 1/2" = 1'-0"D2 Seminar Room Entry Millwork 1 1/2" = 1'-0"E6 Greeting 120 - Bar Table Section 7 RE F . F J F CR CR F F F C R C R CR F F F M M J J J J J J J J J A B GCDEF H J K L M N P Q 2 3 4 6 7 8 10 11 12 1 9 5 Tr a i n i n g 12 6 Me n t o r i n g 12 4 A Me n t o r i n g 12 4 B Me n t o r i n g 12 4 C Me n t o r i n g 12 4 D Me n t o r i n g 12 4 E Me n t o r i n g 12 4 F Co l l a b o r a t i o n 12 0 A Of f i c e 12 9 B Of f i c e 12 9 C Of f i c e 12 9 D Of f i c e 12 9 E St o r a g e 12 9 F Of f i c e 12 9 G Of f i c e 12 9 H Of f i c e 12 9 J St o r a g e 12 9 K Of f i c e 12 9 L Of f i c e 12 9 M Se m i n a r R o o m 11 7 A Ki t c h e n 11 8 A Ch a i r S t o r a g e 11 7 C Re s t r o o m 23 St o r a g e 11 8 B Ca m p u s R e c r e a t i o n 12 9 Lo b b y 12 9 A In f o 12 0 C Gr e e t i n g 12 0 Di g i t a l A c t i v i t y A r e a 12 0 B St u d e n t S u p p o r t / M e n t o r H u b 12 7 Co r r i d o r 1X Co r r i d o r 32 Co r r i d o r 1D Co r r i d o r 1T Co r r i d o r 1J '1 4 H 3 ' '1 4 L 7 ' '1 4 L 4 ' '1 4 L 5 ' '1 4 L 6 ' '1 4 L 3 ' '1 3 L 4 ' '1 3 L 3 ' '1 3 L 2 ' '1 3 H 1 ' '1 3 L 5 ' '1 3 L 7 ' 1 23D -4 RE S T R O O M S O U T O F S C O P E PR O T E C T A N D / O R RE E S T A B L I S H C O N T I N U I T Y T O AL L L I G H T I N G A N D E L E C T R I C A L DE V I C E S I N A R E A 3D -4 1 1 1 3D -4 3D -4 1 2D -4 2D -4 2D -4 2D -4 2D -4 2D -4 2D -4 3D -4 3D -4 3D -4 2D -4 2D -4 2D -4 2D -4 2D -4 2D -4 2D -4 AC AC AC MO T O R I Z E D OV E R H E A D DO O R MO T O R I Z E D OV E R H E A D DO O R 6D -5 3D -4 1 34 3D -4 1 1 1 3D -4 3D -4 5 1 3D -4 6D -5 6 6 7 6 6 1 3D -4 14 L 5 14 L 5 13 L 7 13 L 7 14 L 5 14 L 5 14 L 6 14 L 6 14 L 6 14 L 6 14 L 6 14 L 5 14 L 6 14 L 4 14 L 4 14 L 4 2 14 L 3 14 L 3 14 L 7 14 L 7 14 L 6 14 L 7 14 L 7 14 L 7 8 8 8 14 L 7 14 L 7 9 10 11 12 13 14 15 8 6D -5 6D -5 4D -4 4D -4 4D -4 4D -4 6D -5 6D -5 4D -4 2D -4 1D -4 1D -4 1D -4 16 16 16 16 2D -4 14 L 3 1 1" C . , 1" C . , 1" C . , AB V . C L G . AB V . CL G . 3 St o r a g e 12 6 B 1 3D -4 4 6D -5 8 17 17 17 5 A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENER AL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMI TED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:KEY NOTES:#1 I N S T A L L B E H I N D F L A T P A N E L D I S P L A Y , C O O R D I N A T E L O C A TION WITH CLASSROOM TECH DEPARTMENT.2 E . C . S H A L L P R O V I D E A N D I N S T A L L C O N D U I T A N D J - B O X E S FOR CRESTRON CONTROLS AS SHOWN. E.C. SHALL COORDINATE E XACT REQUIREMENTS AND LOCATION WITH BYU-I PRIOR TO ROUGH -IN.3 C O O R D I N A T E E X A C T L O C A T I O N A N D C O N N E C T I O N R E Q U I R E M E NTS OF RELOCATED ICE MACHINE PRIOR TO ROUGH IN.4 C O O R D I N A T E E X A C T L O C A T I O N O F R E L O C A T E D R E F R I G E R A T O R PRIOR TO ROUGH IN.5 C O O R D I N A T E E X A C T L O C A T I O N F O R L I G H T B R I T E D E V I C E W ITH ARCHITECTURAL DRAWINGS.6 R O U T E W I R E S T H R O U G H F U R N I T U R E , P R O V I D E A N D I N S T A L L ALL NECESSARY BRACKETS, COVERS, CONNECTORS, ETC. REQUIR ED FOR INSTALLATION.7 R E L O C A T E D A D A A C T U A T O R . 8 C I R C U I T T O P A N E L 1 4 L 1 L O C A T E D I N E L E C T R I C A L R O O M 1 71C (SEE SHEET EG101). PROVIDE (11) NEW 20A SINGLE POLE BREA KERS.9 P R O V I D E A N D I N S T A L L ( 7 ) N E W 2 0 A S I N G L E P O L E B R E A K E RS IN PANEL 13L7.10 P R O V I D E A N D I N S T A L L ( 1 0 ) N E W 2 0 A S I N G L E P O L E B R E A KERS IN PANEL 14L3.11 P R O V I D E A N D I N S T A L L ( 8 ) N E W 2 0 A S I N G L E P O L E B R E A K ERS IN PANEL 14L4.12 P R O V I D E A N D I N S T A L L ( 1 0 ) N E W 2 0 A S I N G L E P O L E B R E A KERS IN PANEL 14L5.13 P R O V I D E A N D I N S T A L L ( 1 3 ) N E W 2 0 A S I N G L E P O L E B R E A KERS IN PANEL 14L6.14 P R O V I D E A N D I N S T A L L ( 1 2 ) N E W 2 0 A S I N G L E P O L E B R E A KERS IN PANEL 14L7.15 N E W J U M B O 1 0 F T . T E L E P O W E R P O L E S U C H A S W I R E M O L D N'800.PROVIDE WILL ALL NECESSARY ACCESSORIES AND COMPONEN TS FOR ACCOMMODATE FURNITURE CONNECTIONS FOR THE CABLI NG AND DEVICES SHOWN AND ONE DUPLEX RECEPTACLE ON POLE .FINISH PER ARCHITECT.16 C O N N E C T T O E X I S T I N G R E C E P T A C L E C I R C U I T A S S H O W N O N PLANS.17 C O O R D I N A T E D E V I C E L O C A T I O N W I T H C A S E W O R K S H O P D R A WINGS PRIOR TO ROUGH-IN.8270 S T AT E O F I D AHO T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers 1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.com3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 04-29-2021 EE200POWER/DATA PLAN1275APRIL 29, 2021BYUI MC ACTIVITES &INVOLVEMENT CENTER REMODEL BID SET SC A L E : 1 / 8 " = 1 ' - 0 " 1 PO W E R P L A N NO R T H 16 ' 8' 0" 1 A d d e n d u m # 1 4 - 2 9 - 2 0 2 1 2 A S I 0 0 1 6 - 2 - 2 0 2 1 3 R F I - 2 4 7 - 6 - 2 0 2 1 4 A S I 0 0 3 7 - 2 2 - 2 0 2 1 5 A S I 0 0 4 7 - 2 2 - 2 0 2 1 5