Loading...
HomeMy WebLinkAboutASBESTOS ABATEMENT REPORT - 21-00877 - 238 Ella Lane - DemolitionAttn: Address:3872 E 400 N Order #:441313 Rigby, ID 83442 Idaho Asbestos Abatement LLP (5178)Customer: Received 09/30/21 Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475 09/30/21Analyzed 09/30/21Reported Analysis Report PLM Analysis Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method: Project:Ella Ln Number: Location:Rexburg, ID Hall09/24/21 1441313-001 Beige, Organically Bound TileLayer 1: None Detected CELLULOSE FIBER10% NON FIBROUS MATERIAL90% Clear, Soft MasticLayer 2: None Detected NON FIBROUS MATERIAL100% Black, Fibrous/Bituminous BackingLayer 3: None Detected CELLULOSE FIBER60% NON FIBROUS MATERIAL40% Rexburg, ID09/24/21 2441313-002 Red/Pink, Organically Bound TileLayer 1: NON FIBROUS MATERIAL96%CHRYSOTILE4% Tan, Soft MasticLayer 2: None Detected NON FIBROUS MATERIAL100% Upstairs09/24/21 3441313-003 Red/Pink, Organically Bound TileLayer 1: NON FIBROUS MATERIAL96%CHRYSOTILE4% Black, Soft MasticLayer 2: None Detected NON FIBROUS MATERIAL100% Rexburg, ID09/24/21 4441313-004 Multi-Colored, Org.Bound/Fibrous Sheet VinylLayer 1: Sample was inhomogenous, subsamples of each component were analyzed separately. CELLULOSE FIBER20% NON FIBROUS MATERIAL60% CHRYSOTILE20% MasticLayer 2: Quantity not sufficient for analysis. Page 1 of 2 Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. The test results apply to the sample as received. PLM Analysis Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method: Project:Ella Ln Number: Location:Rexburg, ID Basement Stair09/24/21 5441313-005 Gray, Organically Bound VinylLayer 1: None Detected NON FIBROUS MATERIAL100% Basement Ceiling09/24/21 6441313-006 Tan/White, Fibrous Ceiling TileLayer 1: None Detected CELLULOSE FIBER90% NON FIBROUS MATERIAL10% Upstairs09/24/21 7441313-007 White, Powdery DrywallLayer 1: None Detected CELLULOSE FIBER10% NON FIBROUS MATERIAL90% Beige, Granular Joint CompoundLayer 2: NON FIBROUS MATERIAL98%CHRYSOTILE2% Garage09/24/21 8441313-008 White, Powdery DrywallLayer 1: None Detected CELLULOSE FIBER10% NON FIBROUS MATERIAL90% White, Granular Joint CompoundLayer 2: None Detected NON FIBROUS MATERIAL100% Garage09/24/21 9441313-009 White, Powdery Only one layer found. DrywallLayer 1: None Detected CELLULOSE FIBER10% NON FIBROUS MATERIAL90% Approved Signatory Reviewed By:Andrew Bruner Total layers analyzed on order: 15 441313-09/30/21 03:03 PM EPA Regulatory Limit: 1% Analyst Thoria Nadiem Page 2 of 2 Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. The test results apply to the sample as received.