Loading...
HomeMy WebLinkAboutCOMCHECK - 21-00285 - 2907 Mendoza Dr - Mendoza ShopGenerated by COMcheck-Web Software Envelope Compliance Certificate Section 1: Project Information Energy Code: 20091ECC Project Title: Project Type: New Construction Construction Site: Mendoza Farms Building Location (for weather data): Climate Zone: Vertical Glazing / Wall Area Pct.: Building Use: Activity Tyoersl 1-Warehouse : Nonresidential Owner/Agent: Rexburg, Idaho 6b 9% Floor Area 6000 Designer/Contractor: MHB Construction, Inc.: Section 2: Envelope Assemblies and Requirements Checklist Envelope Assemblies: Component Name/Description Gross Cavity Cont. R- Proposed Budget U- Area or R-Value Value U-Factor Factona) i Roof: Metal Building, Screw Down, [Bldg. Use 1 - Warehouse] 6000 0.0 30.0 0.032 0.049 Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber 4800 0.0 19.0 0.050 0.069 (compressed at girt), [Bldg. Use 1 - Warehouse] Door: Uninsulated Double -Layer Metal, Swinging, [Bldg. Use 1 - 42 --- --- 0.090 0.700 Warehouse] Door: Insulated Metal, Non -Swinging, [Bldg. Use 1 - Warehouse] 392 --- --- 0.100 0.500 Floor: Unheated Slab -On -Grade, [Bldg. Use 1 - Warehouse] 340 --- --- --- --- (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. 2. Windows, doors, and skylights certified as meeting leakage requirements. 3. Component R-values & U-factors labeled as certified. 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels. 5. 'Other' components have supporting documentation for proposed U-Factors. 6. Insulation installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. 7. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized dampers. 8. Cargo tloors and loading dock doors are weather sealed. 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, are sealed with gasket or caulk. 10.Building entrance tloors have a vestibule equipped with self -closing devices. Exceptions: Building entrances with revolving doors. Doors not intended to be used as a building entrance. Doors that open directly from a space less than 3000 sq. ft. in area. Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doom. Project Title: Report date: 10/12/21 Data filename: Page 1 of 7