HomeMy WebLinkAboutGARAGE SHEARWALLS - 21-00160 - 1354 Clover Ct - New SFRFROST Structural Engineering 1020 Lincoln Road Phone: 208.227.8404 Idaho Falls, ID 83401 Fax: 208.227.8405 www.frost-structural.com SSI No. : Re : Project : Date:SEAL: To : From : Project No. : Reference:Instruction: FSE October 12, 2021 STRUCTURAL SUPPLEMENTAL INFORMATION 1 Garage Front Shearwalls 1354 Clover Court Brandon Hall Kevin Bradshaw IF21-149 See attached sketch allowing for a double-sided shearwall in place of a portal frame system at the small garage door. Garage front wall 10/12/2021 33'-0" X 24'-0" 767 SQ FT 7'-11" X 6'-2" 48 SQ FT 6'-6" X 6'-2" 40 SQ FT 3'-9" X 9'-11" 34 SQ FT 6'-1" X 9'-11" 84 SQ FT 64 SQ FT GARAGE PANTRYMUD LAUNDRYW.I.C. 33'-0" X 24'-0" 767 SQ FT 7'-11" X 6'-2" 48 SQ FT 6'-6" X 6'-2" 40 SQ FT 3'-9" X 9'-11" 34 SQ FT 6'-1" X 9'-11" 84 SQ FT 64 SQ FT GARAGE PANTRYMUD LAUNDRYW.I.C. FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/12/21IF21-1491354 Clover Court 2 of 2 PF PF SHEATHE BOTH SIDES OF THESE WALLS W/ 7/16" SHEATHING. FASTEN W/ 8d NAILS AT 6" O.C. AT PANEL EDGES AND AT 12" O.C. IN FIELD. PORTAL FRAME NOT REQUIRED AT THESE LOCATIONS. TYP- SIMPSON STHD14 (OR SIMILAR) AT ALL PIERS THESE PLANS ARE BEING PROVIDED TO ADDRESS ELEMENTS OF THE STRUCTURAL SYSTEMS THAT DO NOT CONFORM TO THE PRESCRIPTIVE METHODS OF THE INTERNATIONAL RESIDENTIAL CODE (IRC). WE HAVE NOT REVIEWED THE DRAWINGS FOR COMPLIANCE WITH THE IRC. THE INFORMATION REGARDING ELEMENTS THAT DO NOT CONFORM TO THE IRC HAS BEEN GIVEN TO US BY OTHERS. AS ALLOWED BY THE IRC SECTION R301.1, WE HAVE ONLY ADDRESSED THE SPECIFICALLY REQUESTED ELEMENTS. THESE ELEMENTS ARE: 1. LATERAL SHEARWALL DESIGN FOR THE FRONT WALL OF THE GARAGE.