HomeMy WebLinkAboutSTAFF REVIEWS - 09-00075 - AmeriTitle - Tenant FinishCITY 0 At RE, X.BURG Arywriva'5E upn dy Come ng y- March 25, 2009 Permit Number; 09 000,75 Project Name: Project Type: Review Action Amerffirtle Tenant.Finish Com,mercial Tenant Finish Review Item �dm�nistrativ� Revi Ow. Permit Tech Notes Parcel #'s RPRVLYWO020070 ir Streetimpact, water & sewer connection fees for this building were not paid for on the shelf permit because occupancy had not been determined. The property owner can either pay for the entire building now or for this quite now and the other suite when it is, finished. At least 112 is due prior to issuance of this building permit. Contact JaNe'll to discuss this further. 11 RO Box 280 11 E. Main St. Rexraurg, Idaho 83440 Phone (208) 359-302 Fax (208) 358-3022 f ' JL l RE, URG America 'sI `Om i.5i COn m u n i i March 25, 2009 Permit Number: 09 00075 Project Name: Project Type: Review Action AmeriTitle Tenant Finish Commercial Tenant Finish Accessibility Review Interior Environment Exiting Review Energy Conservation Compliance Review Mechanical Review Structural Review Height and Area Review Building Type Compliance Electrical Circuits Review Electrical Service Review Complies with approved Site Plan Review TPD 7-9" (front of toilet to center of roll) 1 112" min. below side grafi bar. Toilet '16-18" from gide wolf. 60" required side wall to Lav counter. Side grab bar starts 1211 max from corner and ends 54" min from corner. No site plan to show accessible parking 1 van space required. Emergency exit lighting required. Bi -level light switching, dimming or motion sensors required an all fighting EXCEPT restrooms, hallways, storage and areas with only 1 light. No mechanical plans submitted The electrical plan is very vague and does not show circuitry, therefore make sure that this is wired to the 2Q08 NEC and any questions Gall Bret at 716-1332. The plan does not shave the electrical service and therefore it must either be shown as a single line. diagram or noted as existing and to remain -revisions required. As per my conservation with Tray Leishman On 31241Q9 at 2:30pm, the service is already mounted to the building and is sufficient for their use -approved to continue. R 0 UQX zeta 19 E. NhIn St. Rexburg, Who 8344 Phone (208) 359-3020 Fax (208) 359-3022 Approved 03/23/2009 03/23/2009 03/23/2009 03/23/2009, 03/23/2,009 03/23/2009 03/23/2009 03/23/2009 03/24!2009 03/24/2009 I TY F4 -E ".URG cs Ealy #xr March 25, 2009 Permit Number: 09 00075 Project Name: Project Type: Review item 4. Review Action AmeriTitle Tenant Finish Commercial Tenant Finish Building Code Fire Compliance Review Parcel #'s RPRVLYWOO,20070 Asti V Basement area shows an area as storage. if this is to be used as storage and is over 1 00sf. This area must be I hour fire rated ,wall, door, ceiling.etc. 5/8th's Type X drywall. with 2 layers on the ceiling. An office area as with the rest of the building would not have to be rated. Please submit letter of intentions for this space, if storage show details on haw to fire rate this lb 19 E Main St. Rexburg, Idaho 8344 Phare (208) 359-3020 Fax (208). 359-3022 W. & I S'.J CITY OF REXBURG ym kz ' Comm uni. March 25, 2009 Permit Number: 09 00075 Project Name: Project Type: Review Action AmeriTitle tenant Finish Commercial Tenant Finish RO Box 280 1 E Maid St. Rexburg, Hahn 83440 Phone (208) 359-3020 Fax (208) 359-3422 Review Item Actions Required forproval _ Approved partm.iont Rb �rew,............., Required Fire Flow Established 03123120D9 Water Supply Hire Access Road Fire Extinguishers Automatic Fire Extinguishing Systems Standpipes Commercial Cooking Alarm Systems Parcel #'s RPRVLYWO020070 Established Established Estinguishers are required in each level of the occupancy. 2A1 OBC extinguishers must be installed before occupancy. Not. required according to plans provided. N/A No cooking on plans Not required according to plans provided. 03/23/2009 03/23/2009 03/23!2009 03/23/2009 03/23/2009 03/23/2009 03/23/2009