HomeMy WebLinkAboutSTAFF REVIEWS - 09-00075 - AmeriTitle - Tenant FinishCITY 0 At
RE, X.BURG
Arywriva'5E upn dy Come ng y-
March 25, 2009
Permit Number; 09 000,75
Project Name:
Project Type:
Review Action
Amerffirtle Tenant.Finish
Com,mercial Tenant Finish
Review Item
�dm�nistrativ� Revi
Ow.
Permit Tech Notes
Parcel #'s
RPRVLYWO020070
ir
Streetimpact, water & sewer connection fees
for this building were not paid for on the shelf
permit because occupancy had not been
determined. The property owner can either pay
for the entire building now or for this quite now
and the other suite when it is, finished. At least
112 is due prior to issuance of this building
permit. Contact JaNe'll to discuss this further.
11
RO Box 280
11 E. Main St.
Rexraurg, Idaho 83440
Phone (208) 359-302
Fax (208) 358-3022
f
' JL l
RE,
URG
America 'sI `Om i.5i COn m u n i i
March 25, 2009
Permit Number: 09 00075
Project Name:
Project Type:
Review Action
AmeriTitle Tenant Finish
Commercial Tenant Finish
Accessibility Review
Interior Environment
Exiting Review
Energy Conservation Compliance Review
Mechanical Review
Structural Review
Height and Area Review
Building Type Compliance
Electrical Circuits Review
Electrical Service Review
Complies with approved Site Plan Review
TPD 7-9" (front of toilet to center of roll) 1 112"
min. below side grafi bar. Toilet '16-18" from
gide wolf. 60" required side wall to Lav counter.
Side grab bar starts 1211 max from corner and
ends 54" min from corner.
No site plan to show accessible parking 1 van
space required.
Emergency exit lighting required.
Bi -level light switching, dimming or motion
sensors required an all fighting EXCEPT
restrooms, hallways, storage and areas with
only 1 light.
No mechanical plans submitted
The electrical plan is very vague and does not
show circuitry, therefore make sure that this is
wired to the 2Q08 NEC and any questions Gall
Bret at 716-1332.
The plan does not shave the electrical service
and therefore it must either be shown as a
single line. diagram or noted as existing and to
remain -revisions required. As per my
conservation with Tray Leishman On 31241Q9 at
2:30pm, the service is already mounted to the
building and is sufficient for their use -approved
to continue.
R 0 UQX zeta
19 E. NhIn St.
Rexburg, Who 8344
Phone (208) 359-3020
Fax (208) 359-3022
Approved
03/23/2009
03/23/2009
03/23/2009
03/23/2009,
03/23/2,009
03/23/2009
03/23/2009
03/23/2009
03/24!2009
03/24/2009
I TY
F4 -E ".URG
cs Ealy #xr
March 25, 2009
Permit Number: 09 00075
Project Name:
Project Type:
Review item
4.
Review Action
AmeriTitle Tenant Finish
Commercial Tenant Finish
Building Code Fire Compliance Review
Parcel #'s
RPRVLYWOO,20070
Asti
V
Basement area shows an area as storage. if
this is to be used as storage and is over 1 00sf.
This area must be I hour fire rated ,wall, door,
ceiling.etc. 5/8th's Type X drywall. with 2 layers
on the ceiling. An office area as with the rest of
the building would not have to be rated. Please
submit letter of intentions for this space, if
storage show details on haw to fire rate this
lb
19 E Main St.
Rexburg, Idaho 8344
Phare (208) 359-3020
Fax (208). 359-3022
W. &
I
S'.J
CITY OF
REXBURG
ym kz ' Comm uni.
March 25, 2009
Permit Number: 09 00075
Project Name:
Project Type:
Review Action
AmeriTitle tenant Finish
Commercial Tenant Finish
RO Box 280
1 E Maid St.
Rexburg, Hahn 83440
Phone (208) 359-3020
Fax (208) 359-3422
Review Item Actions Required forproval _ Approved
partm.iont Rb �rew,.............,
Required Fire Flow Established 03123120D9
Water Supply
Hire Access Road
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systems
Parcel #'s
RPRVLYWO020070
Established
Established
Estinguishers are required in each level of the
occupancy. 2A1 OBC extinguishers must be
installed before occupancy.
Not. required according to plans provided.
N/A
No cooking on plans
Not required according to plans provided.
03/23/2009