Loading...
HomeMy WebLinkAboutCONCRETE TEST 5 - 21-00119 - Adams Elementary School - AdditionFile name: 21020SB10062021EV B81315D8-49E3-453E-B42E-E0D85FAC45B5 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21020 Cumulative Test Load Amount: 10.0 Project Name: Adam's Elementary Test Location: East side Of gymnasium Client: Madison School District Admixtures: Ticket Number: 79110043 Contractor: Mills Concrete Supplier: IMC Mix Number: 3326104 Date: 9/8/2021 Cylinder Log #: 569 Field Test Results: Set #: 1 Slump (inches): 5.8 Slump Maximum (in): Entrained Air (%): 8.00 Entrained Air Spec. (%): Concrete Temperature (°F): 63 Ambient Temperature (°F): 60 Unit Weight (PCF): 135.34 Tested By: L. Clifford Date: 9/8/2021 Picked Up By: E. Vail Date: 9/8/2021 Time: 11:30 AM Max, Min Temperature N/A Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/15/2021 4.00 12.56 34910 2779.46 3,500.00 Type 1 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/6/2021 4.00 12.6 45,645.0 3622.6 3,500.0 Type 2 C 28 10/6/2021 4.00 12.6 45,530.0 3613.5 3,500.0 Type 2 D 28 10/6/2021 4.00 12.6 46,810.0 3715.1 3,500.0 Type 2 Second Break Average: 3750 Date: 10/08/2021 Reviewed By: E. Vail Signature: