Loading...
HomeMy WebLinkAboutSIGN PLANS - 21-00293 - 1450 N 2nd E - Walmart SignsPage 1 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 April 20, 2021 SIGN PACKAGE Walmart #1878 1450 N. 2nd East Rexburg, ID 83440 Page 2 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 Wall Signs W1 W2 W3 W4 W5 W6 W7 W8 W9 Pg# 3 4 5 6 7 8 9 10 11 Main Elevation Side Elevation 1/64”=1’ 1/64”=1’ 1/64”=1’ Rear Elevation 1 2 3 Table of Contents W2 W3 W4 W5 W6 W8 W9 W1 W1 W2 W3 W4 W5 W7 W6 W8 W9 W10 575'-0" 596'-0" 406'-0"352'-0" W7 Page 3 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 Pan-Channel Letters1 Letter Section Detail at CMU Wall Below Roof Line2 REF BLDG EL BO SIGNAGE Drill hole and feed whip through parapet. b ealant at perimeter of conduit. l protection tube furnished n ll per manufactur- er re endations. ti HLC-H 16x140/90 sleeve anchor furnished by Walmart ach sign connection point. 1" OD neoprene/SS bonde nuous multi-component sealant by rac NOTE: LOCATE ANCHORS PER SIGN ATTACHMENT TEMPLATE. GC TO COORDINATE WITH SIGN SHOP/INSTALLER FOR LOCATIONS. Existing CMU. Existing roo Page 4 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 Pan-Channel Letters1 Letter Section Detail at CMU Wall Below Roof Line2 REF BLDG EL BO SIGNAGE Drill hole and feed whip through parapet. b ealant at perimeter of conduit. l protection tube furnished n ll per manufactur- er re endations. ti HLC-H 16x140/90 sleeve anchor furnished by Walmart ach sign connection point. 1" OD neoprene/SS bonde nuous multi-component sealant by rac NOTE: LOCATE ANCHORS PER SIGN ATTACHMENT TEMPLATE. GC TO COORDINATE WITH SIGN SHOP/INSTALLER FOR LOCATIONS. Existing CMU. Existing roo Page 5 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 W3 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 Letter Section Detail & Canopy Attachment Scale: 3/4”=1’ 2 Plastic Formed Letters Scale: 3/8"=1'-0"1 Overall Area: 41.05 SF Formed Aluminum Letters NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. Scale: 3/32"=1' 15 ' - 0 " 2' - 6 " 3’ - 4 5 / 8 ” 12’-1 1/2” Manufacture & Install One (1) Set of Non-Illuminated Formed Aluminum Letters Returns: 1 1/4” Faces: Formed Aluminum Painted White Illumination: None Power: None Installation: Flush to Backer on Canopy with Hardware Provided Page 6 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 W4 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 Letter Section Detail & Canopy Attachment Scale: 3/4”=1’ 2 Plastic Formed Letters Scale: 1/4"=1'-0"1 Overall Area: 94.9 SF Formed Aluminum Letters NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. Scale: 3/32"=1' 15 ' - 0 " Manufacture & Install One (1) Set of Non-Illuminated Formed Aluminum Letters Returns: 1 1/4” Faces: Formed Aluminum Painted White Illumination: None Power: None Installation: Flush to Backer on Canopy with Hardware Provided Home Pharmacy &2' - 6 " 3’ - 4 5 / 8 ” 28’-0 3/8” Page 7 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 Formed Plastic Letters W5 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 V A R I E S R E F E L E V V A I R E S R E F E L E V V A R I E S Install cement plaster to match adjacent. Face to be ush wit h existing EIFS by General Contractor. Plastic mount for all-thread stud typ. By Walmart. Install 1/8" dia all-thread studs into plastic mounts prior to sign installation typ. By Sign Contractor. 3/8" dia. hole lled with adhesive sealant. Coat all-thread stud with adhesive sealant prior to wall attachment typ. By sign contractor. 5/8'' FRT plywood sheathing behind sign by General Contractor. Ref elevation for sign location. Plastic non-illuminated channel letter by walmart. “Adhesive sealant ” is to be product ln-950 by liquid nails or similar polyurethane construction adhesive, meeting astm d3498 and c557 standards, exterior application, weather resistant, low voc, with a minimum shear strength of 250 psi. Prior to performing this work, verify existing substrate material. If existing substrate is CMU or plywood (5/8" or thicker), substrate replacement is not req'd. Refer to signage general notes for additional requirements. Mounting hole patterns for non-illuminated sign installation provided by Walmart. Existing Framing Letter Section Detail & EIFS and Metal Stud Wall Attachment Scale: 3/4"=1'-0" 2 Plastic Formed Letters Scale: 3/8"=1'-0"1 Scale:3/32"=1' Install One (1) Set of Non-Illuminated White Plastic Letters Returns: 1 1/4" Faces: Formed Acrylic Illumination: None Power: None Installation: Flush to building with 1/8" dia all-thread studs into plastic mounts attached prior to sign installation Overall Area: 31.88 SF NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. 2' - 6 " 12’-9” Outdoor 16 ' - 6 " Page 8 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 W6 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 V A R I E S R E F E L E V V A I R E S R E F E L E V V A R I E S Install cement plaster to match adjacent. Face to be ush wit h existing EIFS by General Contractor. Plastic mount for all-thread stud typ. By Walmart. Install 1/8" dia all-thread studs into plastic mounts prior to sign installation typ. By Sign Contractor. 3/8" dia. hole lled with adhesive sealant. Coat all-thread stud with adhesive sealant prior to wall attachment typ. By sign contractor. 5/8'' FRT plywood sheathing behind sign by General Contractor. Ref elevation for sign location. Plastic non-illuminated channel letter by walmart. “Adhesive sealant ” is to be product ln-950 by liquid nails or similar polyurethane construction adhesive, meeting astm d3498 and c557 standards, exterior application, weather resistant, low voc, with a minimum shear strength of 250 psi. Prior to performing this work, verify existing substrate material. If existing substrate is CMU or plywood (5/8" or thicker), substrate replacement is not req'd. Refer to signage general notes for additional requirements. Mounting hole patterns for non-illuminated sign installation provided by Walmart. Existing Framing Letter Section Detail & EIFS and Metal Stud Wall Attachment Scale: 3/4"=1'-0" 2 Plastic Formed Letters Scale: 3/8”=1'-0"1 Scale:3/2"=1' Exit Formed Plastic Letters Install One (1) Set of Non-Illuminated White Plastic Letters Returns: 1 1/4" Faces: Formed Acrylic Illumination: None Power: None Installation: Flush to building with 1/8" dia all-thread studs into plastic mounts attached prior to sign installation Overall Area: 39.88 SF NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. 2' - 6 " 2' 15’-11 1/2" Automotive 16 ' - 0 " Page 9 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 W7 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 V A R I E S R E F E L E V V A I R E S R E F E L E V V A R I E S Install cement plaster to match adjacent. Face to be ush wit h existing EIFS by General Contractor. Plastic mount for all-thread stud typ. By Walmart. Install 1/8" dia all-thread studs into plastic mounts prior to sign installation typ. By Sign Contractor. 3/8" dia. hole lled with adhesive sealant. Coat all-thread stud with adhesive sealant prior to wall attachment typ. By sign contractor. 5/8'' FRT plywood sheathing behind sign by General Contractor. Ref elevation for sign location. Plastic non-illuminated channel letter by walmart. “Adhesive sealant ” is to be product ln-950 by liquid nails or similar polyurethane construction adhesive, meeting astm d3498 and c557 standards, exterior application, weather resistant, low voc, with a minimum shear strength of 250 psi. Prior to performing this work, verify existing substrate material. If existing substrate is CMU or plywood (5/8" or thicker), substrate replacement is not req'd. Refer to signage general notes for additional requirements. Mounting hole patterns for non-illuminated sign installation provided by Walmart. Existing Framing Letter Section Detail & EIFS and Metal Stud Wall Attachment Scale: 3/4"=1'-0" 2 Plastic Formed Letters Scale: 3/8”=1'-0"1 Scale:3/32"=1' Formed Plastic Letters Install Two (2) Set of Non-Illuminated White Plastic Letters Returns: 1 1/4" Faces: Formed Acrylic Illumination: None Power: None Installation: Flush to building with 1/8" dia all-thread studs into plastic mounts attached prior to sign installation Overall Area Per Sign: 37.71 SF x2: 75.42 SF NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. 2’ - 0 1 / 8 ” 1’ - 6 ” Pharmacy Drive-Thru 18'-9 1/8" 19 ' - 6 " 19 ' - 6 " Page 10 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 W8 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 V A R I E S R E F E L E V V A I R E S R E F E L E V V A R I E S Install cement plaster to match adjacent. Face to be ush wit h existing EIFS by General Contractor. Plastic mount for all-thread stud typ. By Walmart. Install 1/8" dia all-thread studs into plastic mounts prior to sign installation typ. By Sign Contractor. 3/8" dia. hole lled with adhesive sealant. Coat all-thread stud with adhesive sealant prior to wall attachment typ. By sign contractor. 5/8'' FRT plywood sheathing behind sign by General Contractor. Ref elevation for sign location. Plastic non-illuminated channel letter by walmart. “Adhesive sealant ” is to be product ln-950 by liquid nails or similar polyurethane construction adhesive, meeting astm d3498 and c557 standards, exterior application, weather resistant, low voc, with a minimum shear strength of 250 psi. Prior to performing this work, verify existing substrate material. If existing substrate is CMU or plywood (5/8" or thicker), substrate replacement is not req'd. Refer to signage general notes for additional requirements. Mounting hole patterns for non-illuminated sign installation provided by Walmart. Existing Framing Letter Section Detail & EIFS and Metal Stud Wall Attachment Scale: 3/4"=1'-0" 2 Plastic Formed Letters Scale: 3/8”=1'-0"1 Scale:3/32"=1' Formed Plastic Letters Install Two (2) Set of Non-Illuminated White Plastic Letters Returns: 1 1/4" Faces: Formed Acrylic Illumination: None Power: None Installation: Flush to building with 1/8" dia all-thread studs into plastic mounts attached prior to sign installation Overall Area: 27.9 SF NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. 13’-11 1/2” Automotive Automotive 2'- 0 " 16 ' - 0 " Page 11 of 12 Revision: Notes: Date: Designer: Salesperson/Project Manager: Address: Customer: Charlie Gibson THIS CUSTOM DESIGN IS THE EXCLUSIVE PROPERTY OF BOOTZ & DUKE SIGN CO. OF PHX, AZ. IT MAY NOT BE REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION. www.bootzandduke.com (602) 272-9356 2831 W. Weldon Ave. Phoenix, AZ 85017 Korinne Walmart #1878 Design # 210627-01 1450 N. 2nd East Rexburg, ID 83400 April 20, 2021 W9 Wall Mounted Sign3 Existing Sign (To Be Replaced) Not To Scale4 V A R I E S R E F E L E V V A I R E S R E F E L E V V A R I E S Install cement plaster to match adjacent. Face to be ush wit h existing EIFS by General Contractor. Plastic mount for all-thread stud typ. By Walmart. Install 1/8" dia all-thread studs into plastic mounts prior to sign installation typ. By Sign Contractor. 3/8" dia. hole lled with adhesive sealant. Coat all-thread stud with adhesive sealant prior to wall attachment typ. By sign contractor. 5/8'' FRT plywood sheathing behind sign by General Contractor. Ref elevation for sign location. Plastic non-illuminated channel letter by walmart. “Adhesive sealant ” is to be product ln-950 by liquid nails or similar polyurethane construction adhesive, meeting astm d3498 and c557 standards, exterior application, weather resistant, low voc, with a minimum shear strength of 250 psi. Prior to performing this work, verify existing substrate material. If existing substrate is CMU or plywood (5/8" or thicker), substrate replacement is not req'd. Refer to signage general notes for additional requirements. Mounting hole patterns for non-illuminated sign installation provided by Walmart. Existing Framing Letter Section Detail & EIFS and Metal Stud Wall Attachment Scale: 3/4"=1'-0" 2 Plastic Formed Letters Scale: 1/2”=1'-0"1 Scale:3/32"=1' Formed Plastic Letters Install Two (2) Set of Non-Illuminated White Plastic Letters Returns: 1 1/4" Faces: Formed Acrylic Illumination: None Power: None Installation: Flush to building with 1/8" dia all-thread studs into plastic mounts attached prior to sign installation Overall Area: 18.75 SF NOTE: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. If mounting through primary hole is obstructed by rebar, metal studs, channels, or other misc. metal, seal primary hole in sign can and mount through the nearest alternate mount- ing hole. Primary holes are indicated with predrilled holes thorugh washers. Alternate holes are indicated with wahsers only or are otherwise marked. NOTE: All sign penetrations above roof level must be a clear minimum of 8" above deck. 2'- 6 " 2'-6" 2 2 3 3 6.25 s.f. 1 1 17 ' - 0 " 17 ' - 0 " 17 ' - 0 "