Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRUSS REPAIR - 21-00160 - 1354 Clover Ct - New SFR
MiTek USA, Inc. 400 Sunrise Avenue, Suite 270 Roseville, CA 95661 Telephone 916-755-3571 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by BMC West-Idaho Falls, ID. August 20,2021 Baxter, David Pages or sheets covered by this seal: R67694529 thru R67694529 My license renewal date for the state of Idaho is May 31, 2023. Idaho COA: 853 21-010940T IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. MiTek USA, Inc. 400 Sunrise Avenue, Suite 270 Roseville, CA 95661 312 812 =4x12 =5x8 =3x4 =MT20HS 5x12 =3x4 =10x16 =5x6 =5x8 =3x4 =4x5 9 1 2 14 1312 11 28 29 10 8 3 18 4 7 5 6 1-2-0 -1-2-0 1-2-0 35-2-0 3-11-1 23-0-0 5-0-5 34 -0-0 6-1-3 12-8-5 6-4-10 19-0-15 6-7-2 6-7-2 5-11-11 28-11-11 7-0-15 34-0-0 7-11-14 26 -11-1 8-11-3 18-11-3 10 -0-0 10 -0-08-5-90-3-140-4-75-1-25-1-22-7-67-8-7Scale = 1:66.1 Plate Offsets (X, Y):[2:0-0-9,Edge], [3:0-4-0,0-3-0], [8:0-0-4,Edge], [15:0-1-14,0-0-12], [21:0-1-13,0-0-12] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)35.0 Plate Grip DOL 1.15 TC 0.90 Vert(LL)-0.50 12-14 >803 360 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 BC 0.94 Vert(CT)-0.71 2-14 >563 240 MT20HS 165/146 BCLL 0.0 *Rep Stress Incr YES WB 0.75 Horz(CT)0.16 8 n/a n/a BCDL 7.0 Code IRC2015/TPI2014 Matrix-SH Wind(LL)0.28 12-14 >999 240 Weight: 169 lb FT = 20% LUMBER TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF Stud/Std *Except* 11-6,10-6:2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E OTHERS 2x4 DF Stud/Std BRACING TOP CHORD Structural wood sheathing directly applied or 1-11-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-11 REACTIONS (lb/size)2=1764/0-5-8, 8=1768/0-5-8 Max Horiz 2=220 (LC 9) Max Uplift 2=-396 (LC 10), 8=-292 (LC 11) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/23, 2-4=-5304/1454, 4-5=-3020/821, 5-6=-3551/1064, 6-7=-2365/671, 7-8=-2583/636, 8-9=0/58 BOT CHORD 2-14=-1345/5067, 12-14=-1006/4089, 10-12=-1006/4089, 8-10=-404/2030 WEBS 3-14=-702/318, 14-18=-84/565, 4-18=-76/585, 4-11=-1380/464, 5-11=-1596/544, 6-11=-782/2648, 6-10=-163/538, 7-10=-386/246, 12-18=-9/55 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)All plates are MT20 plates unless otherwise indicated. 5)All plates are 1.5x4 MT20 unless otherwise indicated. 6)Gable studs spaced at 2-0-0 oc. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 396 lb uplift at joint 2 and 292 lb uplift at joint 8. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply R67694529B01Roof Special Structural Gable 1 121-010940T Job Reference (optional) Builders FirstSource (Idaho Falls, ID), Idaho Falls, ID - 83402,Run: 8.43 S Aug 16 2021 Print: 8.430 S Aug 16 2021 MiTek Industries, Inc. Fri Aug 20 10:57:27 Page: 1 ID:Adw4TY6SHGbIIn213FBnc?z36u2-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f August 20,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths