HomeMy WebLinkAboutFA MATERIAL SUBMITTALS - 21-00356 - Adams Elementary School - Addition Fire AlarmPage 1 of 1 Idaho Owned and Operated FAX # 1-208-232-0449 FIRE ALARM MATERIAL SUBMITTALS for the ADAM ELEMENTARY Addition FEATURES & BENEFITS • Up to 1,110 points for greater design flexibility. Additional SLCs can be added until maximum point levels are reached. • Connect up to 17 panels on one site with convenient single- point access; compatible with mixed FACP models • 15 recordable one minute messages can be mapped to eight different EVS buttons • Built-in USB interface for convenient programming • Convenient field-upgradeable firmware • Built-in annunciator with a large 160 character, 4 x40 LCD display, and four programmable buttons minimize time spent executing complex or routine tasks • 16 built-in speaker group switches; expandable to 32 • Integrated dual path IP and POTs communications and optional cellular side-cars for reliable backup • Built-in dual phone line and digital alarm communicator/ transmitter (DACT) for additional communication options • Programmable date setting for automatic and Daylight Saving Time changes • Flexput™ circuits can be individually programmed to function as notification circuits, auxiliary power outputs, or initiating circuits that support both 2 and 4 wire smoke detectors 6820EVS Emergency Voice System and Fire Alarm Control Panel The 6820EVS is a fire alarm control panel (FACP) and emergency mass notification system conveniently integrated and housed in one panel, and meets the requirements for mass notification as described in UL 2572. It can be configured to achieve an overall point capacity of up to 1,110 points and connect up to 17 panels in a single communications link. It has one built-in signaling line circuit (SLC), which can support 159 (SK) System Sensor® sensors and 159 SK modules or 127 (SD) Hochiki® devices per loop. To increase point capabilities, additional SLC loops can be added using the 6815 SLC expander for SK devices or the 5815XL expander for SD devices, increasing the point capacity to a maximum of 1,110 points for SK devices and 635 points for SD devices. Three additional SLCs are needed to reach 1,110 points (SK devices). Four additional SLCs are needed to reach 635 points (SD devices). The common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. It also has a built-in, dual- line POTs and IP communicator and optional cellular side-cars. The emergency communication system operations include an on- board supervised microphone, and all call and non-active call buttons can quickly select all active or all non-active output groups. The system also lets you select an ECS message as a priority over fire. SWIFT® wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install 6820EVS fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6820EVS compatible devices. The 6820EVS has a Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre-trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. It supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. The panel also has four programmable buttons which are ideal for programming simple, complex and routine tasks. SIGNAL LINE CIRCUIT (SLC) The 6815 signal line circuit (SLC) supports multiple device types of SK protocol, while the 5815XL signal line circuit (SLC) supports multiple device types of SD protocol. You cannot mix SD and SK SLC devices on a FACP. The 6820EVS has one built-in signaling line circuit (SLC) which supports multiple devices. Additional points can be added using up to three 6815 SLC expanders to increase overall capacity to 1,110 maximum points (SK devices) or by adding up to four 5815XL SLC expanders to reach 635 maximum points (SD devices). The number of SLCs which can be used within one system is only limited by point count. (See the Manual for additional information.) The 6820EVS SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Troubles (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6820EVS built-in 4 x 40 annunciator with 160 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4 to 7-digit operator's code. 6820EVS KEYPAD PROGRAMMING The 6820EVS system offers several options to simplify and speed- up programming. JumpStart® AutoProgramming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on-site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS), which is Windows® based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows® software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a Windows-based computer. ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6820EVS also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services. UL Listed; CSFM 71650559:0500; FDNY COA# 6249; FM approved; Seismic (CA) (pending) UL listed for Continuous or ANSI 520Hz speaker tones that meet NFPA 72 Low Frequency Signal Requirements for Sleeping Areas when used with the EVS INT50W or EVS 100W amplifiers and compatible speakers ORDERING INFORMATION 6820EVS: Emergency Communication System with FACP. (Red cabinet). COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855: 4x20 LCD remote fire annunciator 58653 or 58654: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 58654 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / IO module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. 6820EVS Product Information 6820EVS COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.silentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SKACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperture SKBEAM: Reflected beam smoke detector without test feature SKBEAMT: Reflected beam smoke detector with test feature SKCONTROL: Supervised control module SKCONTROL6: Six circuit supervised control module SKDUCT: Photoelectric duct smoke detector with extended air speed range SKFIRECO: Four criteria fire and carbon monoxide detector SKHEAT: Fixed thermal detector (135°F) SKHEATROR: Fixed rate of rise detector (135°F) SKHEATHT: Fixed high temperature thermal detector (190°F) SKISO: Fault isolator module SKMINIMON: Mini monitor module SKMONITOR: Monitor module SKMONITOR2: Dual input monitor module SKMON10: 10 input monitor module SKPHOTO: Photoelectric smoke detector SKPHOTOT: Photoelectric smoke detector with thermal (135°F fixed temperature) SKPHOTOR: Photoelectric detector with remote test capability SKPULLSA: Addressable single action pull station SKPULLDA: Addressable dual action pull station SKRELAY: Addressable relay module SKRELAY6: Addressable Six relay control module SKRELAYMON2: Addressable Dual relay/ monitor module SKZONE: Addressable zone interface module SKZONE6: Six zone interface module B210LP: 6" mounting base B501: 4" Flangeless mounting base B200S: Intelligent sounder base B200SLF: Low-frequency intelligent sounder base B224RB: Relay base B224BI: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD5056AB: Addressable 6" base SD5056IB: Addressable 6" short circuit isolator base SD5056RB: Addressable 6" relay base SD5056SB: Addressable 6" sounder base SD500AIM: Addressable input module (switch input) SD500ANM: Addressable notification module SD500ARM: Addressable relay module SD505DTSK: Remote test switch and LED indicator for the SD505DUCTR SD505DUCT: Addressable Duct Smoke Detector. SD505DUCTR: Addressable Duct Detector housing with relay base. SD505HEAT: Absolute temperature heat detector. Trip point range from 135°F150°F (0°C37°C). SD500LIM: Addressable Line isolator module SD500MIM: Addressable Mini input monitor module (switch input) SD505PHOTO: Photoelectric smoke detector SD500PS/PSDA: Addressable Single or dual action pull station SD500SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: “R” indicates red; “W” denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSKWGI: Wireless Gateway WSKPHOTO: Wireless Photoelectric smoke detector WSKPHOTOT: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperture) and B510W 4" base WSKHEAT: Wireless Heat, (135°F fixed temperture) and B510W 4" base WSKHEATROR: Wireless heat, ROR (135°F fixed temperture) and B510W 4" base WSKMONITOR: Wireless monitor module WSKRELAY: Wireless relay module WUSB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 6815: Each Single Line Circuit allows for an additional 159 SK modules and 159 SK sensors to be added to the system-up to 1,110 total points. Supports System Sensor SK devices only. 5815XL: Each Single Line Circuit provides an additional 127 SD devices to be added to the system -for a maximum of 635 points. Supports SD devices only. 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay Interface. Provides 10 Form C relays. 5824: Serial/Parallel Printer Interface Module for printer connection. 5895XL: Power Supply with six Flexput™ circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8”W x 103/16”H x 3”D EVS ACCESSORIES EVS50W: 50 Watt Amplifier* EVS125W: 125 Watt Amplifier* EVS100W: 50/100 Watt Amplifier* EVS100WBU: External Backup Amplifier EVSINT50W: 50 Watt Internal Amplifier EVSCE4: Circuit Audio Expander EVSSW24: 24 Switch Expander EVSVCM: Voice Control Module EVSLOC: Local Operator Console** *Support for up to four amplifiers; 500W maximum. Each amplifier has four built-in speaker circuits expandable to eight. ** Supports up to four EVSLOCs COMMUNICATION OPTIONS CELLCABSK: Cellular communicator, metal enclosure with lock/key* CELLMOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SKIP2: Remote reporting via the Internet. Requires a VisorAlarm® receiver at the central station External Backup Amplifier EVSINT50W: 50 Watt Internal Amplifier For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, Honeywell® and SWIFT® are registered trademarks and Flexput™ is a trademark of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 8004466444. 6820EVS Accessories and Technical Specifications MISC. ACCESSORIES SKNIC: Network Interface Card. Provides a common communications link for the 6820EVS. (Panels cannot be linked together for peer-to-peer networking). SKNICKIT: Installation Accessory Kit SKFML: FiberOptic Multi Mode, transmitter and receiver SKFSL: FiberOptic Single Mode RBB: Remote battery box accessory cabinet or batteries that are too large to fit in the FACP cabinet. Dimensions: 16” W x 10” H x 6” D (406mm W x 254mm H x 152mm D). SKSCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. PHYSICAL Overall Dimensions: 21.59”W x 28.1”H x 5.05”D Shipping Weight: 50 lbs. Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (non- condensing 351606 | A | 11/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 8003280103 ELECTRICAL 6820EVS Primary AC: 120AC @ 60Hz, 3.3A Total Accessory Load: 6A @ 27.4VDC power-limited Standby Current: 190mA Alarm Current: 250mA Battery Charging Capacity: 7 to 35AH Battery Size: 18AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Six conductor wiring: 4 SBUS and 2 Voice Bus FLEXPUT CIRCUITS Six programmable circuits which can be programmed individually as: Notification Appliance Circuits: 3A @ 27.4VDC per circuit, power-limited (with a panel maximum current of 6A) Auxiliary Power Circuits: 3A @ 27.4VDC per circuit, power-limited Initiating Circuits (Circuits 5 and 6 Only): 100mA @ 27.4VDC per circuit, power limited Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits WIRING: See the product manual for wiring details FEATURES & BENEFITS • Converts a conventional two-wire loop to an SLC loop • Six zone inputs • Fully supervised • Support for Class B and Class A wiring • Removable 12 to 18 AWG plug-in terminal blocks • Individual LED for each relay contact • Two module mounting in the IDPACB cabinet • Up to two unused modules can be disabled • Rotary address switches for fast installation • Mounting hardware included • UL Listed SKZONE6 Six Zone Interface Module The inputs on the SKZONE6 share a common FACP sig naling line circuit (SLC) input, and the initiating device circuits share a common external power supply. Otherwise, each input on the module operates independently from the others. If needed, you can disable a maximum of two unused inputs on the SKZONE6 board. It transmits the status of a zone of two-wire detectors to the FACP. Status conditions are reported as normal, open, or alarm. The SKZONE6 supervises the zone of detectors and the connection of the external power supply. All two-wire detectors being monitored must be UL compatible with the SKZONE6. INSTALLATION The SKZONE6 mounts in the Silent Knight IDPACB c abinet. The IDP ACB has a built in chassis that will accommodate one or two SKZONE6 modules. SKZONE6 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 8004466444. SKZONE6 Technical Specifications PHYSICAL Height: 6.8”H x 5.8” W x 1.0”D Shipping Weight: 6.3 oz (196 g) ELECTRICAL Operating Voltage: 15 – 32VDC SLC Standby & Alarm Current: 2mA max SLC Loop Resistance: 40: max. Initiating Device Circuit: Supervised, powerlimited Max. IDC Wiring Resistance: 25: max External Power Supply Standby Current: 50mA Alarm Current: 70mA per module End-ofLine Resistance: 3.9k : ENVIRONMENTAL Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing ORDERING INFORMATION SKZONE6: Six Zone Interface Module ACCESSORIES. IDPACB: SK Module Cabinet. Cabinet holds two SKZONE6. 15.25" H x 12.5" W x 3"D COMPATIBILITY The SKZONE6 is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XLEVS: Addressable fire alarm control panel with an emergency voice system For a list of detectors compatible with the SK ZONE6, see the SKZONE6 Installation Instruction (PN I56344100). Doc 350130 | Rev E | 11/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 8003280103 DescriptionFeatures include an 80-characterbacklit LCD providing easy-to-understand system messages. Theannunciator is ergonomicallydesigned with over-sized buttonsfor the most frequently usedfeatures, like Reset and Silence.In addition to status messagesdisplayed on the LCD, there arefive LEDs for alarm, supervisory,trouble, silence, and AC powerstatus.The annunciator is available in grayto match virtually any decor andred for applications where theannunciator must stand out. Theannunciator enclosure can besurface or flush mounted. A trimring kit is available for surfacemounting. Features• 80-character backlit LCD display(4 lines with 20 characters oneach line)• Tactile and audible feedback• Accepts user codes or firefighter’s key• Larger keypad buttons for systemreset and silence• Install up to twelve 5860s per5820XL/EVS or 5808 system• Install up to eight 5860s per 5700system • Available in red or light gray• Support for simultaneous use ofmultiple 5860s• RS-485 interface to panel• Operation and appearance isidentical to 5860 built-inannunciator• On-board piezo sounder audiblyindicates alarms, troubles, andsupervisories• Five status LEDs for alarm,supervisory, trouble, silence andAC power conditions• Wiring lengths up to 6000 ft. fromthe FACP (depending on wiregauge and number of devices onSBUS)• UL listed, complies with NFPA 72• CSFM approved Electrical SpecificationsOperating Voltage: 24 VDCStandby Current: 20 mA maxAlarm Current: 25 mAWiring Distance: 6,000 max. fromFACP (depending on wire gaugeand number of devices on theSBUS) Mechanical SpecificationsPhysical 9.1” W x 7.4” H x 1.5” D(23.1 W x 18.8 H x 3.8 D cm)Shipping Weight: 2.8 lbs (1.3 kg)Color5860R: Red5860: Gray EnvironmentalOperating Temperature: 32ºF –120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensing CompatibilityThe 5860 is compatible with thefollowing FACP’s:• 5820XL Addressable Fire ControlPanel• 5820XL-EVS Fire Control Panelwith Emergency Voice System• 5808 Addressable Fire ControlPanel• 5700 Addressable Fire ControlPanel PN 350224 Rev G© 2014 Honeywell International Inc 5860 Remote Annunciator Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility.The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnightpanel’s built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple anderror-free system operation. All operations—including reset, silence, detector status checking, fire drill, andprogramming—are identical. Access to the system is through a firefighter’s key or an access code. For security, a special installation code isneeded for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus.Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Bring the power to control an IntelliKnightfire alarm control panel to every area within your facility 5860 INTELLIKNIGHT ACCESSORY INTELLIKNIGHT ACCESSORY Assembled in America This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103,Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444.www.silentknight.com 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remoteannunciators shall have the same control and display layout so as to match the appearance of the built-inannunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciatorsmust have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, SystemTrouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have atravel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciatorkeypad or by using a firefighter’s key. The annunciator must have two levels of user codes that will limit theoperating system programming to authorized individuals. The control panel must allow all annunciators toaccommodate multiple user input simultaneously. Ordering Information5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting ListingsNFPA 72; UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. IX; FM Approved 5860 PAGE 1 OF 2MKT. #8910013 - REV D 1/18 PRINTED IN USA PSN SERIES POWER SUPPLY UL , cUL, CSFM Listed ‡ 361KDVDPSVUHJXODWHGZLWK2XWSXWV ‡ 361KDVDPSVUHJXODWHGZLWK2XWSXWV ‡ 2XWSXWV5DWHGDWDPSVPD[LPXPHDFK ‡ 0D\EHFRQ¿JXUHGDVXSWRWKUHHFODVV³$´6W\OH=QRWL¿FDWLRQFLUFXLWV ‡ DPS9'&SURJUDPPDEOHRXWSXWSRZHU ‡ 6XSHUYLVHG%DWWHU\&KDUJHU#$ VXSSRUWV$+EDWWHULHV ‡ (DV\WRLQVWDOOFDELQHWZLWKOHYHOLQJPRXQWVDQGNH\ORFN ‡ :LULQJNQRFNRXWVSURYLGHGRQVLGHVDQGWRSRIFDELQHW ‡ 7ZR7URXEOH5HOD\V $DW9'&   *HQHUDO6\VWHP7URXEOH SURJUDPPDEOHIRU$&GHOD\   /RZ$&7URXEOHZLWKRSWLRQDOGHOD\VHWWLQJV ‡ 'LDJQRVWLF/('¶V   6WDWXV/('¶VIRU$FWLYH1$&DQG1$&WURXEOHFRQGLWLRQV   6WDWXV/('¶VIRU(DUWK)DXOW $PEHU $& *UHHQ %DWWHU\ )DXOW $PEHU ‡ 7URXEOH0HPRU\IHDWXUHFDSWXUHVWURXEOHVZKLFKKDYHSUHYLRXVO\UHVWRUHG ‡ 6\QFKURQL]HGQRWL¿FDWLRQDSSOLDQFHFLUFXLWV   3RWWHU$06(&2 ®:KHHORFN®*HQWH[®6\VWHP6HQVRU® ‡ &RQ¿JXUDEOHRXWSXWFLUFXLWV ',3VZLWFKVHWVRSWLRQVIRUHDFKFLUFXLW ‡ P$DW9'&LQSXWWULJJHU ‡5HIHUHQFH(2/DOORZV.±.(2/YDOXHWREHXVHG ‡4XDGUDV\QFSURYLGHVSDQHOZLGHV\QFKURQL]DWLRQRIVDPHRUPXOWLSOHEUDQGV ‡3DVV7KUXPRGHDOORZVWKH2XWSXWVWRPDWFKWKH,QSXW6LJQDO Description 7KH361VHULHVRIQRWL¿FDWLRQSRZHUVXSSOLHVRIIHUVUHOLDEOHQRWL¿FDWLRQ SRZHUZLWKXQSUHFHGHQWHGYHUVDWLOLW\7KHSRZHUVXSSOLHVRIIHUHLWKHU RUDPSVRIFRQWLQXRXVSRZHUWKURXJKRURXWSXWVUHVSHFWLYHO\ (DFKRXWSXWLVUDWHGDWDPSVDQGLWPD\EHXVHGFRQWLQXRXVO\ZLWKRXW DQ\GHUDWLQJ 7KHSRZHUVXSSO\RSHUDWHVRQHLWKHU9$&RU9$&SRZHULQSXW DQGKDVDUHJXODWHG9'&RXWSXW,QDGGLWLRQWKHSDQHOFDQFKDUJH XS WR$+EDWWHULHVDQGOHDGVWKHLQGXVWU\LQKRXVLQJXSWR$+ EDWWHULHV7KHFDELQHWLVFRQVWUXFWHGRXWRIJDXJHFROGUROOHGVWHHODQG KDVDGXUDEOHUHGSRZGHUFRDW¿QLVK,QDGGLWLRQDNH\ORFNLVSURYLGHG IRUVHFXULQJWKHGRRU$PSOHHOHFWULFDONQRFNRXWVDUHSURYLGHGRQWKH VLGHVDQGWKHWRSDOORZLQJWKHLQVWDOOHURSWLRQVIRUUXQQLQJZLUHVDQG PDLQWDLQLQJWKHFRUUHFWVHSDUDWLRQV 7KHSRZHUVXSSO\RIIHUVDQLQGXVWU\OHDGLQJ4XDGUDV\QFIXQFWLRQWKDW DOORZVIRUPXOWLSOHVWUREHFLUFXLWVRIGLIIHUHQWEUDQGVWREHV\QFKURQL]HG WRÀDVKDWWKHVDPHWLPH7KHSDQHOFDQKDYHIRXUGLIIHUHQWEUDQGVHDFK FRQQHFWHGWRLWVRZQFLUFXLWDQGDOORIWKHVWUREHVÀDVKWRJHWKHU (DFK RXWSXW FDQ LQGHSHQGHQWO\ EH FRQ¿JXUHG WR SURYLGH RQH RI IRXUV\QFKURQL]DWLRQVRUVWHDG\SRZHU7KLVSURYLGHVXQHTXLYRFDO ÀH[LELOLW\LQQHZDQGUHWUR¿WLQVWDOODWLRQV7KHSDQHOFDQEHFRQ¿JXUHG WRV\QFKURQL]H3RWWHU$06(&2®*HQWH[®:KHHORFN®DQG6\VWHP SDWHQWSHQGLQJ 6HQVRU®VWUREHGHYLFHV(DFKRXWSXWFDQEHFRQ¿JXUHGWKHVDPHV\QF SURWRFRORUVHWLQGHSHQGHQWO\ ,QDGGLWLRQWKH SDQHOKDVDQLQSXW3DVV7KUXPRGHDOORZVWKHRXWSXWVWRIROORZWKHLQSXWVLJQDODQGV\QFXSWKHLQSXWÀ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¿JXUHGIRUYDULRXVDSSOLFDWLRQV DQGLQVWDOODWLRQV(DFKRXWSXWFDQEHLQGHSHQGHQWO\FRQ¿JXUHGIRU&ODVV $RU&ODVV%RSHUDWLRQFRQVWDQWSRZHU$16,7HPSRUDO&RGH6LQJOH 0XOWLSOHRU&RPER,QSXWVRU'RRU+ROGHU3RZHU 'LPHQLRQV:[+[' 6WRFN1XPEHU3615HG(QFORVXUH ௘௘3615HG(QFORVXUH 3RWWHU(OHFWULF6LJQDO&R//&‡6W/RXLV02‡&XVW6HUYLFH‡7HFK6XSSRUW‡&DQDGD ‡ZZZSRWWHUVLJQDOFRP Product includes a 5 year warranty 6 361%ODFN(QFORVXUH Electrical Specs: ‡ 9$&+]LQSXW ‡ $PSV#9$&RU$PSV#9$& ‡ %DWWHU\6WDQGE\&XUUHQWP$ ‡ $ODUP6WDQGE\&XUUHQWP$ QRH[WHUQDOORDG ‡ 7HUPLQDOVVXSSRUW$:*ZLUH 3615HG PAGE 2 OF 2 PSN SERIES POWER SUPPLY MKT. #8910013 - REV D 1/18 PRINTED IN USA N GH Comm Low Battery AC Power Gnd Fault Battery - Battery connection (non-power limited). Use two (2) 12V batteries connected in series. Common relays are non-power limited. 120VAC 50Hz~60Hz 240VAC 50Hz~60Hz Connect to separate unswitched AC circuit LOW AC RELAY NC COM NO TROUBLE RELAY NC COM NO Battery + White Black Ground IN2 - + EOL IN1 - + EOL REF EOL DC PWR - + NAC6 - + NAC4 - + NAC3 - + NAC1 - + NAC2 - + NAC5 - + S1 S2 S3 S4 S5 S6 S8S7 Trigger - + NAC1 NAC4 NAC5 NAC6NAC3NAC2 DC PWR COMM DC Power - + Status LED's E.O.L. ON E.O.L. OFF Bulk Options 120/240 VAC Jumper Position GND FAULT DETECT ENABLE Optional Reference E.O.L. Factory Installed Interconnect. 12 0 | 2 4 0 12 0 | 2 4 0 Fuse PSN-106 Wiring Diagram (QJLQHHULQJ6SHFL¿FDWLRQ 7KHFRQWUDFWRUVKDOOVXSSO\DQGLQVWDOOWKH3RWWHU361SRZHUVXSSO\7KH SRZHUVXSSO\VKDOORSHUDWHRQHLWKHURU9$&LQSXW7KHSDQHO VKDOOEHFDSDEOHRIFRQWLQXRXVORDGSRZHUZLWKRXWDQ\GHJUDGDWLRQWR WKHPDLQVXSSO\RUWKHGLVWULEXWLRQERDUG7KHFDELQHWVKDOOEHFDSDEOHRI KRXVLQJXSWR$+EDWWHULHVDQGWKHSDQHOVKDOOEHFDSDEOHRIFKDUJLQJ XSWR$+EDWWHULHVLQDQH[WHUQDOFDELQHW 7KHSDQHOVKDOOKDYHGLSVZLWFKHVIRUVLPSOLVWLFFRQ¿JXUDWLRQRIWKH V\VWHPDQG/('VWRSURYLGHYLVXDOLQGLFDWLRQWRWKHLQVWDOOHURIWKHVWDWXV RIWKHV\VWHP7KHGLSVZLWFKHVVKDOODOORZIRU$&SRZHUGHOD\VHOHFWLRQ &ODVV$%RSHUDWLRQSHURXWSXW'RRU+ROGHU3RZHURSWLRQVFRQVWDQW DX[LOLDU\SRZHUWULJJHULQSXWW\SH$16,&RGH7HPSRUDO&RGH3DVV 7KUX LQSXWWUDFNLQJ 3RWWHU$06(&2®V\QF*HQWH[®6\QF6\VWHP 6HQVRU®6\QFRU:KHHORFN®V\QF7KH/('VVKDOOSURYLGHLQGLFDWLRQ RIFRPPXQLFDWLRQEHWZHHQWKHSRZHUVXSSO\DQGGLVWULEXWLRQFLUFXLW DVVHPEOLHV7KH/('VVKDOOKDYHGLVWLQFWÀDVKSDWWHUQVWRSURYLGHIXUWKHU LQGLFDWLRQRIWKHWURXEOHVSUHVHQW7KHSDQHOVKDOOKDYHVHOHFWDEOH7URXEOH 0HPRU\WRSURYLGHWKHLQVWDOOHUDQLQGLFDWLRQWKDWDSDVWWURXEOHH[LVWHG RQDFLUFXLWIRUGLDJQRVWLFSXUSRVHV (DFKRXWSXWRIWKHSRZHUVXSSO\VKDOOEHFDSDEOHRIDPSVRIFRQWLQXRXV SRZHUZLWKRXWGHJUDGDWLRQRYHUWLPH7KHSRZHUVXSSO\VKDOOSURYLGHIRU PXOWLSOHFLUFXLWVRIVWUREHDSSOLDQFHV7KHSRZHUVXSSO\VKDOOV\QFKURQL]H WKHÀDVKHVRIDQ\RIWKHDERYHOLVWHGVWUREHDSSOLDQFHVRQDSHUFLUFXLW EDVLV8SWRIRXUGLIIHUHQWVWUREHFLUFXLWVPD\EHFRQQHFWHGDQGDOORI WKHVWUREHVVKDOOÀDVKLQXQLVRQDVUHTXLUHGE\8/,QDGGLWLRQWR WKLV4XDGUDV\QFIHDWXUHWKHSDQHOVKDOODOORZDQ\RIWKHIRXUDERYH PHQWLRQHGV\QFSDWWHUQVDVDQLQSXWDQGSDVVWKLVVLJQDOWKURXJKDQG V\QFKURQL]HWKHRXWSXWVWRPDWFKWKHLQSXWÀDVKSDWWHUQ 1RWH361DQG361GUDZP$ZKHQSRODULW\UHYHUVHVDQGWKHSRZHUVXSSO\LVWULJJHUHG7KHUHLVQRFXUUHQWGUDZLQ6WDQGE\0RGH FEATURES & BENEFITS • New modern profile for improved aesthetics • Stable communication technique with noise immunity • Low standby current • Two-wire SLC connection • Optional remote, single- gang LED accessory • Dual LED design provides 360° viewing angle • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Built-in tamper- resistant feature • Sealed against back pressure • Expanded color options • SEMS screws for wiring of the separate base • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of installation and maintenance SKPHOTOW Series Intelligent PlugIn Photoelectric Smoke Detector Honeywell Silent Knight SKPHOTOW Series plug-in s moke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SKPHOTOW Series detector sensitivity can be p rogrammed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SKPHOTOTW. The SKPHOTORW is a remote test capable detector for use with DNR Series duct detector housings. SKPHOTOW DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A051003, is available at systemsensor.com INSTALLATION The SKPHOTOW Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. • When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SKPHOTOW: Photoelectric smoke detector, white. SKPHOTORW: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white. SKPHOTOTW: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES B3006: White, standard flanged low-profile mounting base. B3006BP: Bulk pack of B3006, package contains 10. B3006IV: Ivory, standard flanged low-profile mounting base. B501WHITE: White, standard European flangeless mounting base. UL listed. B501BL: Black, standard European flangeless mounting base. UL listed. B501IV: Ivory, standard European flangeless mounting base. UL listed. B200SWH: White, Intelligent, programmable sounder base. B200SIV: Ivory, Intelligent, programmable sounder base. B200SRWH: White, Intelligent sounder base for retrofit applications. B200SRIV: Ivory, Intelligent sounder base for retrofit applications. B200SLFWH: White, Low Frequency Intelligent, programmable sounder base. B200SLFIV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SRLFWH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SRLFIV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RBWH: White, plug-in System Sensor relay base. B224RBIV: Ivory, plug-in System Sensor relay base. B224BIWH: White, plug-in System Sensor isolator detector base. B224BIIV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white, 10Pack. CK300IV: Color Kit (includes cover and trim ring), ivory, 10Pack. CK300BL: Color Kit (includes cover and trim ring), black, 10Pack. M020401: Detector test magnet. M020900: Telescoping test magnet. RA100Z: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B3006, white. TR300IV: Replacement trimring for B3006IV, ivory. Photoelectric smoke SKPHOTOW: Photoelectric smoke White, standard flanged B3006: White, standard flanged For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 8003280103 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 8004466444. SKPHOTOW Series Detector Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B3006 base Diameter: 6.2" (156mm) installed in B3006 base 4.1" (104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 32°F to 122°F (0°C to 50°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) UL listed Velocity range: Photo/Photo with Thermal: 0 to 4,000 fpm (0 to 20 m/sec) (suitable for installation in ducts) Humidity: 10% to 93% non-condensing Thermal Ratings: Fixed Temperature Set point: 135°F (57°C) ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Operating Current @ 24VDC: 200PA (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). Doc 351634 | Rev A | 04/18 © 2018 Honeywell International Inc. COMPATIBILITY The SKPHOTOW series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XLEVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S6173 FM approved CSFM: 72720559:0523 DescriptionThe SK-Pull-SA is a single action pull station requiring onlyone motion to activate the station. The SK-Pull-DA is a dualaction pull station requiring two motions to active the station.Both pull stations are designed to work with Silent KnightIntelliknight series fire alarm control panels (FACPs). Features• Installer can open station without causing an alarmcondition • Dual-color LED is visible through handle of station blinksgreen to indicate normal operation and remains steady redin an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act AccessibilityGuidelines (ADAAG) controls and operating mechanismsguidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 lbs maximum pull force toactive • Shell, door, and handle molded from durable LEXAN ® • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activatedappears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually ActuatedSignaling System SK-Pull-SA and SK-Pull-DA The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use withSilent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SAprovide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizeseach manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Intelligent Pull Stations INTELLIKNIGHT ACCESSORY CompatibilityThe SK-Pull-SA and SK-Pull-DA are compatiblewith the following IntelliKnight FACP’s: 5600570058085820XL SK-Pull-SA SK-Pull-DASK-Pull-DA INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SAIntelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knightmodel SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADArequirements for a 5 lb. maximum pull force to activate the pull station. MADE IN AMERICA FORM# 350135 Rev B © 2012 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com SpecificationsPhysicalHeight: 5.5” (14 cm) Width: 4” (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED:Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O)switch which closes upon activation of the pull station ElectricalOperating Voltage: 15–32 VDC Average Operating Current (LED flashing): 300 µA Wire Gauge: Up to 12 AWG (3.1 mm2)Environmental Operating Temperature 32º – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing AccessoriesBG-TR Optional trim ring.SB-I/O Surface backbox dn-3459:a1 • 2/26/10 — Page 1 of 2 STI Stopper® II and Weather Stopper® II Covers for Manual Pull Stations Miscellaneous dn-3459:a1 • K-200 General The Safety Technology International, Inc. Stopper® II cover for manual pull stations helps deter unwanted activation and is also an effective guard against physical damage. It has been proven by use in thousands of installations throughout the world, including schools, hospitals, hotels and stores. The Stopper® II has also been tested and approved by fire prevention and testing authorities. Features • Window made of clear and durable plastic. • Optional warning horn powered by 9 VDC battery. • Provides weatherproofing for outdoor pull stations when equipped with optional gasket (Weather Stopper II). • Fits pull stations from 5-1/2" to 6-3/4”. • Unconditional lifetime guarantee against cover breakage and damage. Applications The Stopper® II can be used in almost any pull station environment. Spacer Installation (SURFACE MOUNT MODELS ONLY) The spacer is used for surface-mounted or oversized manual stations. Longer screws are provided for use with tap-in anchors. Remove knock-out at top or bottom of spacer as necessary. Gasket Installation (WEATHER STOPPER® II MODELS ONLY) Installing neoprene gaskets behind the spacer and/or Stopper® II frame will provide additional weatherproofing. A conduit gasket may be used to seal the top or bottom of the spacer. Size Of Pull Station Accomodated The Stopper® II and Weather Stopper® II can be installed over a flush-mounted station up to 5-1/2" wide and 6-3/4" high. However, the pull station's maximum dimensions will decrease as its depth (distance from the wall) increases, i.e.: a 3/4" deep pull station may be 5-1/2" wide x 6" high; a 1-5/8" deep pull station may be 5" wide x 6" high; a 2-3/8" deep pull station may be 4" wide x 5-3/4" high; a 2-3/4" deep pull station may be 3" wide x 5-1/2" high. See sections “Spacer Installation” and “Gasket Installation”. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S2466 •ULC Listed: S2466 • ADA Compliant • STI-1100 & STI-1130: Factory Mutual Approved • STI-1100 & STI-1130: BSA: 947-81-SA • STI-1100, STI-1130, STI-1250, STI-3150: CSFM AHJ Approval Required • STI-1200, STI-1230, STI-1250: MEA 49-00-E • STI-1250, STI-3150: NEMA-3R When mounted on a smooth surface or when mounted with STI-1280 Back Plate 3459d1.wmf n3 4 5 9 c o v . j p g Page 2 of 2 — dn-3459:a1 • 2/26/10 NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Product Line Information STI-1100Stopper® II, flush mount, with horn. STI-1130Stopper® II, surface mount, with horn. STI-1200Stopper® II, flush mount, without horn. STI-1230Stopper® II, surface mount, without horn. STI-1250Weather Stopper® II, flush mount. STI-3150Weather Stopper® II, surface mount. Stopper® II (at right) Weather Stopper® II (at left) 3459d3.wmf STI-1200Stopper® II, flush mount, without horn. DescriptionThe Model SK-Duct Air Duct Smoke Detector utilizesphotoelectric technology for the detection of smoke. Itprovides early detection of smoke and products ofcombustion present in air moving through HVAC ducts inCommercial and Industrial applications. The SK-Duct is in a heavy duty gray steel back box with aclear cover. It features a pivoting housing that fits bothsquare and rectangular footprints capable of mounting to a round or rectangular duct. It installs quickly and easily. The unit senses smoke in the most challenging conditions,operating in airflow speeds of 100 to 4000 feet per minute,temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). Features • Versatile mounting options: square or rectangularconfiguration• New Cover tamper signal• LED alarm indication and communication on sensorhead• Detects and limits the spread of smoke•Rugged steel back box with clear plastic cover•Easy to clean• Large terminal connection screws• Transparent cover for convenient visual inspection• Patented sampling tube installs from front or back of thedetector with no tools required• Available space within housing to accommodatemounting of relay module• UL listed SK-DUCTIntelligent Air DuctSmoke Detector The SK-Duct Intelligent air duct smoke detector is used with SK-PhotoR (included) for detecting smoke andproducts of combustion present in air moving through an HVAC air handling system. When smoke is detected ina duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending onprogramming and wiring, turns off fans, blowers, and other devices. The duct housing allows for mounting ofSK-Relay addressable relay module. Now there's even more power and flexibility available to the IntelliKnightfamily of products! Detect smoke in air handling systems and air handling equipment with Silent Knight's addressable duct smoke detector INTELLIKNIGHT ACCESSORY SK-DUCT Specifications Physical(Rectangular): 14.38 in (37 cm) Length; 5in (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square): 7.75 in (19.7cm) Length; 9 in (22.9cm) Width; 2.5 in (6.35cm) Depth Weight: 1.6lb (0.73kg) EnvironmentalOperating Temperature: -4ºF – 158ºF (-20ºC – 70ºC) Humidity: 0% – 95% (non-condensing) Air Velocity100 to 4000 ft/min (0.5 – 20.3 m/sec.) Electrical (using SK-Photo or SK-PhotoR)Operating Voltage: 15–32 VDCStandby Current: 300 µA @ 24 VDC max.Alarm Current: 6.5 mA @ 24 VDC max (with LED on) INTELLIKNIGHT ACCESSORY Model SK-DUCTAir Duct Smoke Detector Engineering Specifications The air duct smoke detector shall be a SK-Duct photoelectric duct smoke detector. The detector housing shallbe UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smokedetector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to4000 ft/min (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed orimproperly installed. It shall be capable of local testing via magnetic switch or remote testing using theRTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for12–18AWG wiring. The unit housing shall be capable of mounting a relay module. MADE IN AMERICA FORM# 350122 Rev D ©2010 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specificationsare subject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com Ordering Information SK-Duct Intelligent non-relay duct smoke detectorSK-Photo Addressable Photo DetectorSK-PhotoR Addressable Photo Detector with remote testcapability (included with SK-Duct)SK-Relay Addressable Relay Module, must be added ifrelay function is required, (fits in housing)Accessories†DST1 Metal Sampling Tube Duct Width up to 1’DST1.5 Metal Sampling Tube Duct Widths 1’ - 2’DST3 Metal Sampling Tube Duct Widths 2’ – 4’DST5 Metal Sampling Tube Duct Widths 4’ – 8’DST10 Metal Sampling Tube Duct Widths 8’ – 12’DH400OE-1 Weatherproof EnclosureETX Metal Exhaust Tube Duct width 1’RA100Z Remote LED AnnunciatorDCOIL Duct accessory coil, required if using with SK-Photo and not SK-PhotoR (included) withSK-DuctRTS151 Magnetic Remote Test stationRTS151KEY Key-Activated Remote Test station M02-04-00 Test MagnetP48-21-00 Replacement End Cap for Metal Sampling TubeAPA151 Remote annunciator with piezo alarm Important Notes: • The use of either RTS151 or RTS151KEY requires theinstallation of an accessory coil, DCOIL, sold separately.Please refer to the SK-Duct installation instructions formore information • The RTS151/RTS151KEY test coil circuit requires anexternal 24VDC power supply which must be UL listed. Accessory Current Loads at 24 VDC Device Standby Alarm RA100Z 0mA 12mA Max. RTS151 0mA 12mA Max. RTS151KEY 12mA 12mA Max. DST5 SK-Photo Addressable Photo DetectorSK-Duct Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK-Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK-Relay, the relay is triggered by the FACP. Features • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible–can be mapped to zone conditions • Polling LED visible through the cover plate • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed SK-Relay The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of eachmodule is selected using the built in rotary switches. For more information about the Intelliknight system, or to locate you nearest source, please call 800-328-0103. Intelligent Relay Module INTELLIKNIGHT ACCESSORY SK-Relay Installation The SK-Relay mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A surface mount electrical box (System Sensor®PN SMB500) is available from Silent Knight CompatibilityThe SK-Relay is compatible with the followingIntelliKnight FACP’s:5820XL580857005600 (Rev 2.0 or higher) INTELLIKNIGHT ACCESSORY Model SK-RelayIntelligent Relay Module MADE IN AMERICA FORM# 350127 Rev C © 2011 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com SpecificationsPhysicalHeight: 4.65” Width: 4.25” Depth: 1.1” Shipping Weight: 6.3 oz (196 g) ElectricalOperating Voltage: 15 – 32 VDC Current Draw: 6.5 mA max (LED on) Operating Current: 230 µA (LED flashing) direct poll 255 µA (LED flashing) group poll End-of-Line Resistance: not used Standby Current: 300 µA max @ 24 VDC (one communication every 5 sec with LED enabled) LED Current: 5.5 mA (with LED latched on) SLC Loop Resistance: 40 max. Relay Contact Ratings3.0A @ 30 VDC resistive 0.9A @ 110 VDC resistive 0.9A @ 125 VAC resistive 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) DescriptionThe SK-Minimon is an addressablemonitor modules for use with theIntelliKnight fire alarm controlpanels (FACPs). The SK-Minimonacts as an interface to contactdevices, such as waterflowswitches and pull stations. The SK-Minimon supports Class Bsupervised wiring to the loaddevice. Conventional 4-wire smokedetectors can be monitored foralarm and trouble conditions The SK-Minimon can be mountedin a single gang junction boxdirectly behind the monitoreddevice. Its small size and lightweight allow it to be installedwithout rigid mountingrequirements.Features• Single contact monitor• SK-Minimon support for Class B(Style B) contact monitor wiring• Small and lightweight size allowsfor flexible mounting options• Rotary address switches for fastinstallation• UL listed Specifications Electrical Standby Current: 400 uA max @24 VDC with comm.Voltage Range: 15 - 32 VDCEnd of Line Resistance: 47 k Ohms PhysicalDimensions:2.75” W x 1.3" H x 0.5" DWeight: 1.2 oz (37 g)EnvironmentalOperating Temperature:32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing CompatibilityThe SK-Minimon is compatible withthe following IntelliKnight Systems:5820XL580857005600 (Rev 2.0 or higher)SK-FFT ApprovalsUL approved CSFM FM Approved SK-Minimon The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm controlpanels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and otherapplications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Intelligent Mini Monitor Module INTELLIKNIGHT ACCESSORY SK-Minimon INTELLIKNIGHT ACCESSORY MADE IN AMERICA FORM# 350133 Rev C © 2011 Honeywell International Inc This document is not intended to be used for installation purposes. Wetry to keep our product information up-to-date and accurate. We cannotcover all specific applications or anticipate all requirements. Allspecifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent KnightSK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The deviceshall be capable of Styles A and B supervised wiring to the load device.The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Speakers offer high fidelity and high volume sound output • 520 Hz capable with compatible FACP • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21⁄8 inch back box . Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.Agency Listings 7320-1653:0505S4048 FM approved except for ALERT models 3057493 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm Electrical/Operating Specications Nominal Voltage (speakers)25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 VDC/FWR 1,2 Operating Voltage Range (includes re alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3. 520Hz capable with compatible FACP. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions Ceiling Speaker Ceiling Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86601 • 03/17 L-Series Ordering Information Ceiling Mount White Red Description SPCWL SPCRL Speaker only SPSCWL SPSCRL Speaker Strobe SPSCWL-P — Plain, Speaker Strobe SPSCWL-SP — Fuego, Speaker Strobe SPSCWL-CLR-ALERT — Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring Surface Mounting Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box SPSCWL Agency Listings 7320-1653:0505S4048 FM approved except for ALERT models 3057493 Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, 185 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Seakers offer high fidelity and high volume sound output • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21⁄8 inch back box. Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall- mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm .97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe (including lens and speaker) 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm Electrical/Operating Specications Nominal Voltage (speakers)25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 DC/FWR1,2 Operating Voltage Range (includes re alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd UL Current Draw Data UL Max Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft) 77 80 83 86 UL Anechoic (dBA @10 ft) 77 80 83 86 Sound Output Speaker ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft) 79 82 85 88 UL Anechoic (dBA @10 ft) 79 82 85 88 L-Series Dimensions Wall-Mount Speaker Wall-Mount Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86701 • 03/17 L-Series Ordering Information Wall Mount White Red Description SPWL SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT — Speaker Strobe, Amber Lens SPSWL-CLR-ALERT — Speaker Strobe Clear Lens — SPSRL-SP Speaker Strobe, Fuego Accessories White Red Description RFPW RFP 7 in × 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All -P models have a plain housing (no “FIRE” marking on the cover) Surface Mounting Wall-Mount Speaker Strobe with SBBSPL Surface Mount Back Box SPSWL Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, WhiteSWL Agency Listings Outdoor, Selectable- Output Speaker Strobes and Dual- Voltage Evacuation Speakers for Wall Applications SpectrAlert® Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features t 8FBUIFSQSPPGQFS/&."9 *1 t 3BUFEGSPN¡'UP¡' t 1MVHJOEFTJHOSFEVDFTHSPVOEGBVMUT t 6OJWFSTBMNPVOUJOHQMBUFXJUIPOCPBSETIPSUJOHTQSJOHUIBUUFTUT XJSJOHDPOUJOVJUZCFGPSFEFWJDFTBSFJOTUBMMFE t 'JFMETFMFDUBCMFDBOEFMBTFUUJOHT           BOE t "VUPNBUJDTFMFDUJPOPGPSWPMUPQFSBUJPOBUBOE  DBOEFMB t 3PUBSZTXJUDIGPSTQFBLFSWPMUBHF BOE7SNT BOEQPXFS TFUUJOHT   BOEXBUUT t $PNQBUJCMFXJUI4ZTUFN4FOTPSTZODISPOJ[BUJPOQSPUPDPMBOE MFHBDZ4QFDUS"MFSUQSPEVDUT t 5BNQFSSFTJTUBOUDPOTUSVDUJPO t -JTUFEGPSDFJMJOHPSXBMMNPVOUJOH SpectrAlert Advance PGGFSTUIFCSPBEFTUMJOFPGPVUEPPS TQFBLFSTBOETQFBLFSTUSPCFTJOUIFJOEVTUSZ'SPNNFUBMBOEQMBTUJD PVUEPPSCBDLCPYFT UPXIJUFBOESFEQMBTUJDIPVTJOHT UPXBMMBOE DFJMJOHNPVOUJOHPQUJPOT 4QFDUS"MFSU"EWBODFDBONFFUWJSUVBMMZBOZ BQQMJDBUJPOSFRVJSFNFOU 8BMMNPVOUPVUEPPSTQFBLFSTBOETQFBLFSTUSPCFTDBOCFVTFE JOEPPSTPSPVUEPPSTJOXFUPSESZBQQMJDBUJPOT BOEDBOQSPWJEF SFMJBCMFPQFSBUJPOGSPN¦¡'UP¡'5IFTFTQFBLFSTQSPWJEF BCSPBEGSFRVFODZSFTQPOTFSBOHF MPXIBSNPOJDEJTUPSUJPOBOE NBJOUBJOBIJHITPVOEQSFTTVSFMFWFMBUBMMUBQTFUUJOHTUPQSPWJEF BDDVSBUFBOEJOUFMMJHJCMFCSPBEDBTUPGFWBDVBUJPONFTTBHFT -JLFUIFFOUJSF4QFDUS"MFSU"EWBODFMJOF XBMMNPVOUPVUEPPSTQFBLFST BOETQFBLFSTUSPCFTJODMVEFBWBSJFUZPGGFBUVSFTUIBUJODSFBTF BQQMJDBUJPOnFYJCJMJUZBOETJNQMJGZJOTUBMMBUJPO'JSTU m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nBOHFTBOEJNQSPWFESFTJTUBODFUPTBMUXBUFS DPSSPTJPO,OPDLPVUTMPDBUFEPOUIFCBDLFMJNJOBUFUIFOFFEUPESJMM IPMFTGPSTDSFXJONPVOUJOH1MBTUJDBOENFUBMXFBUIFSQSPPGCBDL CPYFTDPNFXJUI£JODIUPQBOECPUUPNDPOEVJUFOUSJFTBOE£JODI LOPDLPVUTBUUIFCBDL"TDSFXJO/15QMVHXJUIBO0SJOHHBTLFU GPSBXBUFSUJHIUTFBMJTJODMVEFEXJUIFBDICBDLCPY&4 "7%4 SpectrAlert® Advance Outdoor Speaker and Speaker Strobe Specifications Architectural/Engineering Specications General 4QFDUS"MFSU"EWBODFPVUEPPSTQFBLFSTBOETQFBLFSTUSPCFTTIBMMNPVOUUPBXFBUIFSQSPPGCBDLCPY"VOJWFSTBMNPVOUJOHQMBUFTIBMMCF VTFEGPSNPVOUJOHDFJMJOHBOEXBMMQSPEVDUT5IFOPUJmDBUJPOBQQMJBODFDJSDVJUBOEBNQMJmFSXJSJOHTIBMMUFSNJOBUFBUUIFVOJWFSTBMNPVOUJOH QMBUF"MTP 4QFDUS"MFSU"EWBODFTQFBLFSTUSPCFT XIFOVTFEXJUIUIF4ZODt$JSDVJU™.PEVMFBDDFTTPSZ TIBMMCFQPXFSFEGSPNBOPODPEFE OPUJmDBUJPOBQQMJBODFDJSDVJUPVUQVUBOETIBMMPQFSBUFPOBOPNJOBMPSWPMUT8IFOVTFEXJUIUIF4ZODt$JSDVJU.PEVMF WPMUSBUFE OPUJmDBUJPOBQQMJBODFDJSDVJUPVUQVUTTIBMMPQFSBUFCFUXFFOBOEWPMUTWPMUSBUFEOPUJmDBUJPOBQQMJBODFDJSDVJUPVUQVUTTIBMMPQFSBUF CFUXFFOBOEWPMUT0VUEPPS4QFDUS"MFSU"EWBODFQSPEVDUTTIBMMPQFSBUFCFUXFFOo¡'BOE¡'GSPNBSFHVMBUFE%$ PSGVMMXBWF SFDUJmFE VOmMUFSFEQPXFSTVQQMZ Speaker 4QFBLFSTIBMMCFB4ZTUFN4FOTPS4QFDUS"MFSU"EWBODF.PEFM@@@@@@EVBMWPMUBHFUSBOTGPSNFSTQFBLFSDBQBCMFPGPQFSBUJOHBUPS OPNJOBM7SNT4QFBLFSTIBMMCFMJTUFEUP6OEFSXSJUFST-BCPSBUPSJFT4UBOEBSE4GPSPVUEPPSmSFQSPUFDUJWFTJHOBMJOHTZTUFNT4QFBLFS TIBMMIBWFBGSFRVFODZSBOHFPGUP )[BOETIBMMIBWFBOPQFSBUJOHUFNQFSBUVSFGSPNo¡'UP¡'4QFBLFSTIBMMIBWFQPXFS UBQTBOEXBUUBHFTFUUJOHTUIBUBSFTFMFDUFECZSPUBSZTXJUDIFT5IFTQFBLFSNVTUCFJOTUBMMFEXJUIJUTXFBUIFSQSPPGCBDLCPYJOPSEFSUP SFNBJOPVUEPPSBQQSPWFEQFS6-MJTUJOH45IFTQFBLFSTIBMMCFTVJUBCMFGPSVTFJOBJSIBOEMJOHTQBDFTBOEXFUFOWJSPONFOUT Speaker Strobe Combination 5IFTQFBLFSTUSPCFTIBMMCFB4ZTUFN4FOTPS.PEFM@@@@@MJTUFEUP6-BOE6-BOECFBQQSPWFEGPSmSFQSPUFDUJWFTJHOBMJOH TZTUFNT4QFBLFSTIBMMCFDBQBCMFPGPQFSBUJOHBUPSOPNJOBM7SNTBOETIBMMIBWFBGSFRVFODZSBOHFPGUP )[4QFBLFS TIBMMIBWFQPXFSUBQTUIBUBSFTFMFDUFECZSPUBSZTXJUDI5IFTUSPCFTIBMMDPOTJTUPGBYFOPOnBTIUVCFXJUIBTTPDJBUFEMFOTSFnFDUPSTZTUFN BOEPQFSBUFPOFJUIFSPSWPMUT5IFTUSPCFTIBMMBMTPGFBUVSFTFMFDUBCMFDBOEFMBPVUQVU QSPWJEJOHPQUJPOTGPSPSDBOEFMBXIFO PQFSBUJOHPOWPMUTBOE        PSDBOEFMBXIFOPQFSBUJOHPOWPMUT5IFTUSPCFTIBMMDPNQMZXJUI UIF"NFSJDBOTXJUI%JTBCJMJUJFT"DUSFRVJSFNFOUGPSWJTJCMFTJHOBMJOHBQQMJBODFT nBTIJOHBU)[PWFSUIFTUSPCFTFOUJSFPQFSBUJOHWPMUBHF SBOHF5IFTQFBLFSTUSPCFNVTUCFJOTUBMMFEXJUIJUTXFBUIFSQSPPGCBDLCPYJOPSEFSUPSFNBJOPVUEPPSBQQSPWFEQFS6-5IFTQFBLFSTUSPCF TIBMMCFTVJUBCMFGPSVTFJOXFUFOWJSPONFOUT Physical Specications Operating Temperature o¡'UP¡' o¡$UP¡$ Dimensions, Wall-Mount SPS Speaker Strobe †-¨†8¨†% JODMVEJOHMFOTBOETQFBLFS SP Speaker †-¨†8¨†% Dimensions, Wall-Mount Weatherproof Back Box †-¨†)¨†% Electrical/Operating Specications Nominal Voltage (speakers)7PS7 OPNJOBM Maximum Supervisory Voltage (speakers)7%$ Strobe Flash Rate nBTIQFSTFDPOE Nominal Voltage (strobes)3FHVMBUFE7%$'83PSSFHVMBUFE%$'83 Operating Voltage Range (includes re alarm panels with built in sync) UP7 7OPNJOBM PSUP7 7OPNJOBM Operating Voltage with MDL Sync Module UP7 7OPNJOBM PSUP7 7OPNJOBM Frequency Range UP )[ Power ž ›  XBUUT "7%4 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC FWR DC FWR Standard Candela Range            /" /"    /" /"    /" /"    /" /"    /" /"   High Candela Range  /" /"228   /" /"    /" /"    /" /" 258 Sound Output UL Reverberant (dBA @ 10 ft.) 2W 1W ½ W ¼ W Outdoor Speaker     Outdoor Speaker/Strobe  83  Dimensions Candela Derating 'PS,TFSJFTQSPEVDUTVTFEBUMPX UFNQFSBUVSFT MJTUFEDBOEFMBSBUJOHTNVTUCF SFEVDFEJOBDDPSEBODFXJUIUIJTUBCMF Strobe Output (cd) Listed Candela Candela rating at –40°F  %POPUVTFCFMPX¡'                  5.48˝ .97˝ 2.83˝ 6.45˝ 5.48˝2.83˝ 2.83˝ 1.60˝ 6.45˝ Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe 0IJP"WFOVFt4U$IBSMFT *- 1IPOF4&/403t'BY ª4ZTUFN4FOTPS 1SPEVDUTQFDJmDBUJPOTTVCKFDUUPDIBOHFXJUIPVUOPUJDF7JTJUTZTUFNTFOTPSDPN GPSDVSSFOUQSPEVDUJOGPSNBUJPO JODMVEJOHUIFMBUFTUWFSTJPOPGUIJTEBUBTIFFU "7%4t Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes Wall Mount White Red Description 418, 413, 0VUEPPS4QFBLFS JODMVEFTQMBTUJDXFBUIFSQSPPGCBDLCPY 4148, †4143, †0VUEPPS4QFBLFS4USPCF 4UBOEBSEDE JODMVEFTQMBTUJDXFBUIFSQSPPGCBDLCPY 4148,$-3 "-&35 —0VUEPPS4QFBLFS4USPCF 4UBOEBSEDE $MFBS-FOT "-&351SJOUFE JODMVEFTQMBTUJDXFBUIFSQSPPGCBDLCPY —4143), 0VUEPPS4QFBLFS4USPCF )JHIDE      JODMVEFTQMBTUJDXFBUIFSQSPPGCBDLCPY Accessories White Red Description .8##8 .8## 8BMM .FUBM8FBUIFSQSPPG#BDL#PY Notes: "EEi3wUPNPEFMOVNCFSGPSXFBUIFSQSPPGSFQMBDFNFOUEFWJDF OPCBDLCPYJODMVEFE FH 418,3 †"EEi1wUPNPEFMOVNCFSGPSQMBJOIPVTJOH OPi'*3&wNBSLJOHPODPWFS FH 4148,1 i4UBOEBSEDEwSFGFSTUPTUSPCFTUIBUJODMVEF      BOEDBOEFMBTFUUJOHTi)JHIDEwSFGFSTUPTUSPCFTUIBUJODMVEF   BOE DBOEFMBTFUUJOHTWhen replacing standard outdoor units, both the device and back box must be replaced. Surface Mounting Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box Wall-Mount Speaker with Metal Weatherproof Back Box 4143, † 9Copyright © 2001-2017, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. ELECTROMAGNETIC DOOR HOLDER/RELEASES WALL MOUNTED MODEL 997M tWall mount tConcealed wiring t Shipping weight: 2-1/2 lbs. (1.1 kg) t Total projection: 3-5/8" (92mm) t Mounting requirements: 2" x 4" x 1-3/4" (51 x 102 x 45mm) outlet box t Wall must be properly reinforced and outlet box adequately fastened t 2 year limited warranty tANSI/C00011 t Voltage and current: 120VAC, 60Hz., .020 amp 24VAC/DC, 60Hz., .020 amp 12VDC, .040 amp t For 50-55 lbs. of holding force, specify voltage 120VAC, 60Hz .017 amp 24VAC, 60Hz .080 amp 24VDC, .068amp 12VDC, .180amp 240VAC, 50/60Hz. .009 amp tWall mount tConcealed wiring t Shipping weight: 2 lbs. (0.9 kg) t Total projection: 2-5/8" (67mm) t Mounting requirements: 2" x 4" x 1-3/4" (51 x 102 x 45mm) outlet box t Wall must be properly reinforced and outlet box adequately fastened t 2 year limited warranty tANSI/C00011 t Voltage and current: 120VAC, 60Hz., .020 amp 24VAC/DC, 60Hz., .020 amp 12VDC, .040 amp t For 50-55 lbs. of holding force, specify voltage 120VAC, 60Hz .017 amp 24VAC, 60Hz .080 amp 24VDC, .068amp 12VDC, .180amp 240VAC, 50/60Hz. .009 amp 1" (25.4) 1" (25.4)2-5/8 (67) MODEL 998M MODEL 998M