HomeMy WebLinkAboutCONCRETE TEST 3 - 19-00577 - Ollie Manor - New MFRFile Name:
21020FB09142021EV
DDA8D934-F670-4A82-8154-090185F7052E 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
21020
Cumulative Test Load Amount:
5.5
Project Name:
Adam's Elementary
Test Location:
Interior slab around few spots inside the building
Client:
Madison School District
Admixtures:
NA
Ticket Number:
9977
Contractor:
Mills Concrete
Supplier:
Idaho Materials
Mix Number:
3325605
Pour Date:
9/7/2021
Cylinder Log #:
564
Field Test Results:
Set #:
1
Slump
(inches):
3.8
Slump
Maximum
(in):
5.0
Entrained Air
(%):
1.40
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
62
Ambient
Temperature
(°F):
45
Unit Weight
(PCF):
146.14
Tested By:
Y. Kabwika
Date:
9/7/2021
Time Tested:
7:00 AM
Picked Up By:
Yannick Kabwika
Date:
9/7/2021
Time:
12:00 PM
Max, Min Temperature
0
File Name:
21020FB09142021EV
DDA8D934-F670-4A82-8154-090185F7052E 2
Initial Break Results:
Cylinder
#:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Break
Type:
Required
28 day
Strength
(psi):
A 7 9/14/2021 4.00 12.56 52,800.0 4203.82 Type 6 3,500.0
Date:
09/20/2021
Reviewed By:
E. Vail
Signature: