HomeMy WebLinkAboutCONCRETE TEST 3 - 19-00577 - Ollie Manor - New MFRFile Name: 21020FB09142021EV DDA8D934-F670-4A82-8154-090185F7052E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21020 Cumulative Test Load Amount: 5.5 Project Name: Adam's Elementary Test Location: Interior slab around few spots inside the building Client: Madison School District Admixtures: NA Ticket Number: 9977 Contractor: Mills Concrete Supplier: Idaho Materials Mix Number: 3325605 Pour Date: 9/7/2021 Cylinder Log #: 564 Field Test Results: Set #: 1 Slump (inches): 3.8 Slump Maximum (in): 5.0 Entrained Air (%): 1.40 Entrained Air Spec. (%): Concrete Temperature (°F): 62 Ambient Temperature (°F): 45 Unit Weight (PCF): 146.14 Tested By: Y. Kabwika Date: 9/7/2021 Time Tested: 7:00 AM Picked Up By: Yannick Kabwika Date: 9/7/2021 Time: 12:00 PM Max, Min Temperature 0 File Name: 21020FB09142021EV DDA8D934-F670-4A82-8154-090185F7052E 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 9/14/2021 4.00 12.56 52,800.0 4203.82 Type 6 3,500.0 Date: 09/20/2021 Reviewed By: E. Vail Signature: