Loading...
HomeMy WebLinkAboutCONCRETE TEST - 19-00577 - Ollie Manor - New MFRFile Name: 21020FB09152021EV 1A2CCD53-C0C5-4ED5-8DDB-769037808A1D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21020 Cumulative Test Load Amount: 10.0 Project Name: Adam's Elementary Test Location: Sidewalk along the fence on S 2nd E, last half on sidewalk on the Northwest side of the building Client: Madison School District Admixtures: Ticket Number: 10034 Contractor: Mills Concrete Supplier: IMC Mix Number: 3326104 Pour Date: 9/9/2021 Cylinder Log #: 577 Field Test Results: Set #: 1 Slump (inches): 6.0 Slump Maximum (in): 5.0 Entrained Air (%): 7.00 Entrained Air Spec. (%): Concrete Temperature (°F): 63 Ambient Temperature (°F): 50 Unit Weight (PCF): 139.36 Tested By: Y. Kabwika Date: 9/9/2021 Time Tested: 8:15 AM Picked Up By: E. Vail Date: 9/9/2021 Time: 10:30 AM Max, Min Temperature 104.7, 39.7 File Name: 21020FB09152021EV 1A2CCD53-C0C5-4ED5-8DDB-769037808A1D 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 9/16/2021 4.00 12.56 33,105.0 2635.75 Type 1 3,500.0 Date: 09/20/2021 Reviewed By: E. Vail Signature: