Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS - 21-00739 - 582 E 4th S - Solar Panels
ISSUED FOR: PERMIT DATE 09/11/2021 SCALE: NTS JOB NO.: -www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM KRISTINE ANDERSON DESIGNED BY CONTRACTOR INFORMATION P V - 1 582, E 4TH S, REXBURG, ID 83440 - Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ ADDITIONAL NOTES P L A N S E T L E G E N D S H E E T I N D E X V I C I N I T Y M A P A P P L I C A B L E C O D E S MSPSUBACDCSLCMINVJBCBFMC A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N 1 5 - J I N K O S O L A R J K M 3 8 0 M - 6 R L 3 - B ( 3 8 0 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 6 0 0 0 H - U S ( 6 0 0 0 W ) I N V E R T E R S Y S T E M S I Z E : 5 . 7 0 0 K W D C S T C A R R A Y A R E A : 3 0 8 . 1 7 S F K R I S T I N E A N D E R S O N 5 8 2 , E 4 T H S , R E X B U R G , I D 8 3 4 4 0 - 1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8. DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9. THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11. IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12. EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13. A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14. PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15. GFCI PROTECTION IN INVERTER.OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X F L E X I B L E M E T A L L I C C O N D U I T ( E ) E X I S T I N G ( N ) N E W E X T E X T E R I O R I N T I N T E R I O R E M T E L E C T R I C A L M E T A L L I C T U B I N G R M T R I G I D M E T A L L I C T U B I N G V O C V O L T A G E O P E N C I R C U I T V M P V O L T A G E A T M A X . P O W E R I S C S H O R T C I R C U I T C U R R E N T I M P C U R R E N T A T M A X . P O W E R N T S N O T T O S C A L E PROJECT INFORMATION, VICINITY MAP 9/14/2021 INV MTRMSP ACD ISSUED FOR: PERMIT DATE 09/11/2021 SCALE: NTS JOB NO.: -www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM KRISTINE ANDERSON DESIGNED BY CONTRACTOR INFORMATION P V - 2 582, E 4TH S, REXBURG, ID 83440 - Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ SITE PLAN S C A L E : N T S TOTAL # OF PANELS:15ROOF TYPE:SHINGLE A E R I A L V I E W S C A L E : N T S N A B B R E V I A T I O N S I N V I N V E R T E R M S P M A I N S E R V I C E P A N E L A C A C D I S C O N N E C T M T R M E T E R SITE PLAN, AERIAL VIEW R O O F D E S C R I P T I O N R O O F A R R A Y P I T C H A Z I M U T H # 1 3 0 ° 1 7 0 ° 3 ' P A T H W A Y ROOF #13'PATHWAY 1 8 " C L E A R A N C E 18"CLEARANCE NOTE: AC DISCONNECT WITHIN 3FT OF THE METER.9/14/2021 ISSUED FOR: PERMIT DATE 09/11/2021 SCALE: NTS JOB NO.: -www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM KRISTINE ANDERSON DESIGNED BY CONTRACTOR INFORMATION P V - 3 582, E 4TH S, REXBURG, ID 83440 - Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS ELECTRICAL SINGLE LINE DIAGRAMELECTRICAL E Q U I P M E N T C A L L O U T S 5,700W TOTAL SOLAR ARRAY15 JINKO SOLAR JKM380M-6RL3-B (380W) PANELS1 STRING OF 15 MODULES CONNECTED IN SERIES @ INVERTERWIRE AND CONDUIT CALLOUTS123EBACKFEED 26 D C AB200ANNGNNSOLADECK M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/ROOF P E N E T R A T I O N , 6 0 0 V 6.0kW INVER T E R U N G R O U N D E D SOLAREDGE S E 6 0 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 240VAC, 25A, N E M A 3 R , U L L I S T E D , (W/ INTEGRA T E D D C D I S C O N N E C T ) WITH INTEG R A T E D G F P , W / I N T E G R A T E D A F P SQUARE D S A F E T Y S W I T C H , # H 2 2 2 N R B P/N 3112 600 V D C , 6 0 A , N E M A 3 R , 1 0 , 0 0 0 AIC, UL, NEM A , C S A , N O M C E R T I F I E D W / 4 0 A FUSES200A MAIN S E R V I C E P A N E L (W/ 200A MAI N B R E A K E R C E N T R E F E D ) (2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT E L E C T R I C A L N O T E S S C A L E : N T S SOLAREDGE P 4 0 1 O P T I M I Z E R O N E P E R P A N E L F EBI-DIRECTIO N A L U T I L I T Y M E T E R D A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . SINGLE LINE DIAGRAM R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) M O D U L E : J I N K O S O L A R J K M 3 8 0 M - 6 R L 3 - B ( 3 8 0 W ) V o c = 4 4 . 2 2 V I s c = 1 1 . 1 2 A V m p = 3 6 . 9 V I m p = 1 0 . 3 0 A G _~3BMPPT 1MPPT 2 2 A F O N E P E R P A N E L 1 5 M O D U L E S I N S E R I E S S T R I N G 1 1 3CL1L2GL1L2N N O T E : A C D I S C O N N E C T W I T H I N 3 F T O F T H E M E T E R . 40A 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N ISSUED FOR: PERMIT DATE 09/11/2021 SCALE: NTS JOB NO.: -www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM KRISTINE ANDERSON DESIGNED BY CONTRACTOR INFORMATION P V - 4 582, E 4TH S, REXBURG, ID 83440 - Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ REQUIRED SIGNAGEWARNING:2. LABEL FOR SOLAR AC DISCONNECT:WARNINGWARNING: S Y S T E M A C V O L T A G E : 2 4 0 V REQUIRED SIGNAGEWARNING:WARNINGWARNING: T O T A L R A T E D A C A M P S : 4 0 A S Y S T E M A C V O L T A G E : 2 4 0 V REQUIRED SIGNAGE 3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECTINVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE.DIR E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M D C V O L T A G E : 2 4 0 V M A X D C C I R C U I T C U R R E N T : 2 5 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A 8. THE F O L L O W I N G S I G N M U S T B E P R O V I D E D O N THE OUT S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E PANELBO A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:10. SIGN A G E R E Q U I R E D A T S T R I N G I N V E R T E R P E R N E C 6 9 0 . 5 3 : 9. SIGNA G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 7. AT PV D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 6. REFLE C T I V E P L A C A R D A T S E R V I C E S T A T I N G : DUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEM "SOLAR AC DISCONNECT"ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION. • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • Premium solar panel factories in USA and Malaysia EAGLE 66TR G4 370-390 WATT TILING RIBBON MODULE Positive power tolerance of 0~+3% KEY FEATURES BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US SOLAR BRAND THE MOST DEPENDABLE TR Technology Tiling Ribbon eliminates cell gaps to increase module efficiency and power. 9BB Half Cell Technology Uniquely designed 9 busbar half cut solar cells deliver ultra-high power in a small footprint. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Thick and Tough Engineered with 35mm frame, 3.2mm front side glass, and Type 1 backsheet for added durability. Leading Warranty 12-year product and 25-year linear power warranty; 98% guaranteed first year, max 0.55% annual loss. 25 ENGINEERING DRAWINGS PACKAGING CONFIGURATION TEMPERATURE CHARACTERISTICS MAXIMUM RATINGS MECHANICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS No. of Cells 132 (2x66) Dimensions 1855x1029x35mm (73.03×40.51×1.37 in) Weight 21.5 kg (47.40 lbs) Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass Frame Anodized Aluminum Alloy Junction Box IP67 Rated Output Cables 12 AWG, 2053mm (80.83in) or Customized Length Connector MC4 Fire Type Type 1 Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) 2 pallets = 1 stack; 30pcs/pallets, 60pcs/stack, 720pcs/ 40’HQ Container Temperature Coefficients of Pmax -0.35%/°C Temperature Coefficients of Voc -0.28%/°C Temperature Coefficients of Isc 0.048%/°C Nominal Operating Cell Temperature (NOCT)45 ± 2°C Operating Temperature (°C)-40°C~+85°C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 20A Module Type JKM370M-6RL3-B JKM375M-6RL3-B JKM380M-6RL3-B JKM385M-6RL3-B JKM390M-6RL3-B STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax)370Wp 275Wp 375Wp 279Wp 380Wp 283Wp 385Wp 286Wp 390Wp 290Wp Maximum Power Voltage (Vmp)36.71V 33.49V 36.80V 33.57V 36.90V 33.70V 37.02V 33.90V 37.15V 34.02V Maximum Power Current (Imp)10.08A 8.22A 10.19A 8.31A 10.30A 8.39A 10.40A 8.45A 10.50A 8.53A Open-circuit Voltage (Voc)44.02V 41.55V 44.12V 41.64V 44.22V 41.74V 44.34V 41.85V 44.47V 41.97V Short-circuit Current (lsc)10.90A 8.80A 11.01A 8.89A 11.12A 8.98A 11.22A 9.06A 11.32A 9.14A Module Efficiency STC (%)19.38%19.65%19.91%20.17%20.43% ELECTRICAL PERFORMANCE & TEMPERATURE DEPENDENCE BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US *STC: Irradiance 1000W/m2 NOCT: Irradiance 800W/m2 *Power measurement tolerance: +/- 3% Cell Temperature 25°C Ambient Temperature 20°C AM = 1.5 AM = 1.5 Wind Speed 1m/s ny re es the rig expl any e inforThe compa serv final ht for anation on of th mation presented hereby. JKM370-390M-6RL3-B-A2-US Voltage (V) Temperature Dependence of Isc, Voc, Pmax Current-Voltage & Power-Voltage Curves (390W) Front Side Back Length: +/- 2mm Width: +/- 2mm Height: +/- 1mm Row Pitch: +/- 2mm Cell Temperature (°C) • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • UL61730 Certification • ISO45001:2018 Occupational Health & Safety Standards 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR.JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years 1 5 10 15 20 25Gu a r a n t e e d p o w e r p e r f o r m a n c e 97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature:JKM330M - 60HBL Code Cell Code Backsheet Code Cellnull Full null White null NormalH Half B Black L Diamond 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR.JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years1510152025Gu a r a n t e e d p o w e r p e r f o r m a n c e 97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature:JKM330M - 60HBL Code Cell Code Backsheet Code Cellnull Full null White null NormalH Half B Black L Diamond The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependenceof Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-VoltageCurves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A 18 5 5 m m ( 7 3 . 0 3 " ) 1029 mm (40.51") A A H 1 3 6 0 m m ( 5 3 . 5 4 " ) 8 6 0 m m ( 3 3 . 8 6 " ) 981mm (38.62") 35 35 R4.5 14 9 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline 35 3 5 C CB B A The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-VoltageCurves (380W) 5 10 15 20 25 30 35 40 45 5000 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A 18 5 5 m m ( 7 3 . 0 3 " ) 1029 mm (40.51")A A H 1 3 6 0 m m ( 5 3 . 5 4 " ) 8 6 0 m m ( 3 3 . 8 6 " ) 979mm (38.54") 35 35 R4.5 14 9Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-VoltageCurves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A 18 5 5 m m ( 7 3 . 0 3 " ) 1029 mm (40.51") A A H 1 3 6 0 m m ( 5 3 . 5 4 " ) 8 6 0 m m ( 3 3 . 8 6 " ) 979mm (38.54") 35 35 R4.5 14 9Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependenceof Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-VoltageCurves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A 18 5 5 m m ( 7 3 . 0 3 " ) 1029 mm (40.51")A A H 1 3 6 0 m m ( 5 3 . 5 4 " ) 8 6 0 m m ( 3 3 . 8 6 " ) 981mm (38.62") 35 35 R4.5 14 9 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating,High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline 35 3 5 C CB B A IN V E R T E R S www.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 AUtility Monitoring, Islanding Protection, C o u nt r y C o nfi g u ra b l e T h re s h o l d s Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 WADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. P O W E R O P T I M I Z E R Power Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 solaredge.com PV power optimization at the module level Specifically designed to work with SolarEdge inverters Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Up to 25% more energy Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading Fast installation with a single bolt Flexible system design for maximum space utilization 25 YEARWARRANTY Power Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 06/2020/V02/ENG ROW. Subject to change without notice. (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed.(2) For other connector types please contact SolarEdge.(3) For dual version for parallel connection of two modules use the P485. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module is supported. When connecting a single module, seal the unused input connectors using the supplied pair of seals. OPTIMIZER MODEL(typical module compatibilty) P370(60/72 Cell modules) P401(For high power 60/72-cell modules) P404(for 60/72-cell short strings) P405(for high-voltagemodules) P485 (for high-voltage modules) P500(for 96-cellmodules) P505(for highercurrentmodules)UNIT INPUT Rated Input DC Power(1)370 400 405 405 485 500 505 W Absolute Maximum Input Voltage(Voc at lowest temperature)60 80 125 80 83 Vdc MPPT Operating Range 8 - 60 12.5 - 80 12.5 - 105 8 - 80 12.5-83 Vdc Maximum Short Circuit Current (Isc)11 11.75 11 10.1 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x29.5 / 5.08 x6.02 x 1.16 129 x 89 x 42.5 / 5.1 x 3.5 x 1.7 129 x 90 x 49.5 / 5.1 x 3.5 x 1.9 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)655 / 1.5 775 / 1.7 845 / 1.9 750 / 1.7 1064 / 2.3 gr / lb Input Connector MC4(2)Single or Dual MC4(2)(3)MC4(2) Input Wire Length 0.16 / 0.52 m / ft Output Connector MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 Relative Humidity 0 - 100 % PV SYSTEM DESIGN USING ASOLAREDGE INVERTER(4)(5) SINGLE PHASEHD-WAVE SINGLE PHASE THREE PHASE THREE PHASE FOR 277/480V GRID Minimum String Length (Power Optimizers) P370, P401, P500(6)8 16 18 P404, P405, P485, P505 6 14 (13 with SE3K(7))14 Maximum String Length (Power Optimizers)25 50 50 Maximum Power per String 5700 5250 11250(8)12750(9)W Parallel Strings of Different Lengths or Orientations Yes (4) It is not allowed to mix P404/P405/P485/P505 with P370/P401/P500/P600/P650/P730/P801/P800p/P850/P950 in one string.(5) For SE15k and above, the minimum DC power should be 11KW. (6) The P370/P401/P500 cannot be used with the SE3K three phase inverter (available in some countries; refer to the three phase inverter SE3K-SE10K datasheet).(7) Exactly 10 when using SE3K-RW010BNN4 (8) For the 230/400V grid: it is allowed to install up to 13,500W per string when the maximum power diference between each string is 2,000W.(9)For the 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power diference between each string is 2,000W MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL