Loading...
HomeMy WebLinkAboutPLANS - 21-00728 - 525 N 5th W - TWAS Tank Dome Cover.pdfPLAN VIEW ELEVATION VIEW CODEPAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM RN DOME STANDARD INSTALLATION DETAILS18581D1A2B1 RN CENTER RING GENERAL ARRANGEMENT1CRGA05B2 RN DOME STANDARD INSTALLATION DETAILS (ACC.)18581D1A3B3 RN3 TEMPORARY SAFETY TIE OFF ASSEMBLY2SFTTIEOFF5AB4 -N 300 SERIES SSWIREROPE P3/8" 7X19 STRAND17WIREROPESS38-5 -N 300 SERIES SSWIRE ROPE CLIP AND THIMBLE KIT23372T45-6 -N 300 SERIES SSROPE GRAB CLIP 3/8"18201T68-7 8 -N 7075-T733/8" x 1 1/4" LOCK BOLT GRIP #10803BLTLK03751250-9 -N 60613/8" HUCK BOLT COLLAR803COLLK0375-10 -N A2BOLT 7MM X 20MM10BLTHSM720MMA2-11 -N A2WASHER FLAT 7MM10WSHCS7MMA2-12 -N 18-8 SS1/4" X 3/4" SS TRILOBE SCREW W/ WASHER374SCWTRI02500750188-13 -N F593C1/2" X 1 1/4" HEX HD. BOLT17BLTHS05001250F593C-14 -N F593C1/2" X 3 3/4" HEX HD. BOLT21BLTHS05003750F593C-15 -N F593C1/2" X 4" HEX HD. BOLT21BLTHS05004000F593C-16 -N 18-8 SSWASHER 1/2" (LOCK)59WSHLS0500188-17 -N A316NUT 1/2" HEX HEAD59NUTHS0500316-18 -N 18-8 SSTEK SCREW #14 X 1 1/4"407SCWTEK141250188-19 -N 18-8 SSTEK SCREW #14 X 3/4"187SCWTEK140750188-20 -N 18-8 SSTEK SCREW #14 X 3"36SCWTEK143000188-21 -N ALUMINUMDRIVE RIVET 3/8 X 0.781"63RIVDAL38198-22 -N ALUMINUMPOP RIVET P3/16" 126-.250" GRIP AB6-4ACLD ALUM.95RIVPALSL316250-23 -N ULM SILICONEPECORA 890 SILICONE SEALANT 20oz SG TUBE ALUM13PEC890SAA20OZ-24 25 -N3ALUM 1100-0HUB COVER FOR P16 HUBS6HC16B26 -N4ALUM 1100-0HUB COVER FOR P19 HUBS10HC19B27 28 -N76061-T6HUB TOP #1-16‘18581D1HT1B29 -N76061-T6HUB BOTTOM #1-16‘18581D1HB1B30 -N76061-T6HUB UNIVERSAL #2-16‘68581D1HU2B31 -N76061-T6HUB TOP #2A-16‘, FOR TEMPORARY TIE-OFF28581D1HT2AB32 -N76061-T6HUB BOTTOM #2A-16‘, FOR TEMPORARY TIE-OFF28581D1HB2AB33 -N106061-T6HUB TOP #3-19‘58581D1HT3B34 -N106061-T6HUB BOTTOM #3-19‘58581D1HB3B35 -N106061-T6HUB TOP #4-19‘58581D1HT4B36 -N106061-T6HUB BOTTOM #4-19‘58581D1HB4B37 38 -N106005A-T6/6061-T6BEAM #158581D1S1B39 -N126005A-T6/6061-T6BEAM #258581D1S2B40 -N106005A-T6/6061-T6BEAM #358581D1S3B41 -N146005A-T6/6061-T6BEAM #4108581D1S4B42 -N126005A-T6/6061-T6BEAM #5108581D1S5B43 44 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #158581D1B1B45 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #258581D1B2B46 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #358581D1B3B47 -N36005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #4108581D1B4B48 -N26005A-T6 / 6061-T6BATTEN WITH SILICONE GASKET #5108581D1B5B49 50 -N123003-H16PANEL #148581D1P1B51 -N103003-H16PANEL #1 W/VENT PUNCHING18581D1P1VB52 -N143003-H16PANEL #258581D1P2B53 -N173003-H16PANEL #358581D1P3B54 -N143003-H16PANEL #438581D1P4B55 -N113003-H16PANEL #4 W/ MANWAY CUTOUT18581D1P4MB56 -N143003-H16PANEL #4 W/NOZZLE CUTOUT18581D1P4NB57 58 -N143003-H16FLASHING108581D1FLB59 -N3ALUM 3003COUNTER FLASHING108581D1CF1B60 -N2ALUM 3003COUNTER FLASHING108581D1CF2B61 -N1ALUM 3003NOTCHED COUNTER FLASHING168581D1CFRTB62 -N0ALUM 3003.050" X 2" X 51" ALUM.10CFSPL051-63 -N0ALUM 3003.050" X 2" X 6" ALUM.20CFSPL006-64 65 RN91 PIER LAYOUT18581D1PRGAB66 RN48 24 IN DOME SQ. MANWAY1MWSQ24B67 RN32 20" DIA. VENT ASSEMBLY W/ BIRD SCREEN1VAB20BALB68 -I/E25 4" 150# R.F.S.O. HILLSIDE NOZZLE18581D1NZL04B69 -N2EPDMFLASHING BOOT #19SQ101BA-70 -N2EPDMFLASHING BOOT #21SQ201BA-71 72 -N ALUM 6061-T6ALUM. SURFACE MOUNT HINGE (NO HOLES)8SURFMNTHNGALNH-73 -N F593C3/8" X 1 1/4" HEX HEAD BOLT34BLTHS03751250F593C-74 -N A3043/8" FLAT WASHER34WSHFS0375304-75 -N A3163/8" HEX NUT34NUTHS0375316-76 -N6ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1001B77 -N11ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1002B78 -N5ALUM 6061-T6L3" X 3" X 3/8", SUPT. ANGLE18581D1003B79 -N ALUM 6061-T63" X 3" X 3/8" X 148" LG. ALUM. ANGLE1DOMEANG33375148-80 -N LT GRAY RAL7035 TOP COAT (POWDER)1PNTP7035DV-81 -N LT GRAY PRIMER (POWDER)1PNTPPGDV-82 -N LT GRAY RAL7035 TOP COAT BASE (TU)1PNTP7035DVTU-83 -N TOP COAT CATALYST (TU)1PNTPMT330DVTU-84 -N PRIMER CATALYST (TOUCH UP)1PNTLPCATTU-85 -N PAINT BRUSH 1/2IN4PNTBRH12-86 -N PRIMER BASE (TOUCH UP)1PNTLPGTU-87 ACCESSORY ORIENTATION CHART RADIUSREF DEGREESIZESERVICEITEM 9'-3 3/16"344.25ƒ24"24 IN DOME SQ. MANWAY67 2'-10 9/32"146.25ƒ‘20"20" DIA. VENT ASSEMBLY W/ BIRD SCREEN68 9'-11"57.25ƒ‘4"4" 150# R.F.S.O. HILLSIDE NOZZLE69 F.L.F.L.#1FLASHING BOOT #170 F.L.F.L.#2FLASHING BOOT #271 0 PROJ # 1/16" 5/32"1/8"1/16" X = “1.0ƒ / X.X = “0.5ƒ 1/32" 1/32" 0 - 4" HOLE TO HOLE TOLERANCE:1/32" 3/16"LINEAR TOLERANCE: ANGULAR DEVIATION 130" - 240" TOLERANCES UNLESS OTHERWISE NOTED 240"+ PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 4" - 48"48" - 130" 1/16"DWG # SCALE: NTS JOB # PARENT: 1/32" THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.PROJECT LOCATION:CHECKED BYDRAWN BYDATEREVISION DESCRIPTION CUSTOMER NAME: PROJECT NAME: D 8581D1A1 REV DWG SIZE: 08581 D1 CERTIFIED: APPROVED FOR CONSTRUCTIONSTORTEK REXBURG DOME COVER REXBURG, IDRELEASED FOR FABRICATION JRB JWC8/31/2021 ALUMINUM GEODESIC DOME FOR A ‘24'-7 3/8" TANK ASSY. WT:1599# 3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999 LINEAR TOLERANCE: SQUARENESS TOLERANCE: “3/32" +0" / -1/8" COLUMN TOLERANCES 1 2 3 4 2 A 3 4 2 3 4 2 A 3 4 2 3 4 P 1 P 1 P 1 P 1 V P 1 P 2 P 3 P 3 P 4 P 4 N P 2 P 3P4M P 2 P 3 P 4 P 2 P 3 P 4 P 2 1 2 3 4 4 5 5 1 2 3 44 55 1 2 3 4 4 5 5 1 2 3 4 4 5 5 1 2 3 4 4 5 5 DESIGN CRITERIA: DESIGN (PER AWWA D108-19) WIND DESIGN: 90 mph PER ASCE 7-05 ROOF LIVE LOAD: 25 PSF GROUND SNOW LOAD: 50 PSF DESIGN PRESSURE/VACUUM: ATMOSPHERIC OPERATING PRESSURE/VACUUM: ATMOSPHERIC 24'-7 3/8" NOMINAL TANK I.D.4'-1"68 0ƒ 270ƒ 180ƒ 90ƒ4 4 68 67 69 71 79 78 77 70 80 NOTES: ALL MATERIAL IS MILL FINISH ALUMINUM UNLESS NOTED PANELS, FLASHING AND HUB COVERS 3003-H16 OR 5052-H32 HUBS AND PLATES 6061-T6 OR 5052-H32 BEAM AND BATTEN STRIPS 6005A-T6 OR 6061-T6 FASTENERS HUCK BOLTS - ALUMINUM 7075-T7 - ANODIZED FINISH DETAIL E PANEL LABELING ORIENTATION MARK IS ON THE RIGHT SIDE OF THE HOLE WHEN VIEWED FROM THE TOP PANEL CORNER MARKS ARE LABELED W/ "P" PANEL NUMBER AND "B" BEAM NUMBER OPPOSITE SIDE OF PANEL CORNER P1 B1 HUB COVER SEALANT AROUND ENTIRE HUB COVER PERIMETER 3/8" DIA. ALUM HUCK BOLT AND COLLAR. EACH END OF BEAM FLANGE TO DOME HUB MIN OF 4 PLC'S TOP & BOTTOM FLANGE BOTTOM HUB TOP HUB FIELD APPLY SEALANT ON COVER, HUB, BATTEN AND PANEL GAPS #14 X 3" TEK SCREW W/ WASHER APPLY SEALANT BETWEEN WASHER AND HUB COVER DOME PANEL DETAIL D TYPICAL DOME BEAM CONNECTION DETAIL C TYPICAL HUB, COVER & BATTEN INSTALLATION DOME FLASHING DOME PANEL .050" ALUM BATTEN BAR W/ GASKET DOME STRUT PIERTOP HUB HUB COVER #14 X 3" TEK SCREW W/ WASHER APPLY SEALANT BETWEEN WASHER AND HUB COVER 1/4" X 3/4" TRILOBE SCREW W/ WASHER FIELD APPLY SEALANT ON COVER, HUB, BATTEN AND PANEL GAPS FLASHING OVERLAPS HUB (FIELD CUT AS NEEDED) DOME PANEL 3/8" DRIVE RIVET THRU PANEL INTO HUB ALIGNMENT HOLE. TYP ALL 3 PANEL CORNERS 3/8" DIA. ALUM HUCK FASTENER TYP ALL HUB TO STRUT CONNECTIONS REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS JOB # THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.DWG SIZE: B DWG # TOLERANCES UNLESS OTHERWISE NOTED PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 130" - 240" LINEAR TOLERANCE: HOLE TO HOLE TOLERANCE: 240"+48" - 130"4" - 48"0 - 4" ANGULAR DEVIATION 1/32" 1/32" 1/16" 1/32" 5/32" 1/32" 1/8" 1/16" 3/16" 1/16" X = ±1.0° / X.X = ±0.5° TOTAL WT:PARENT: PROJ # 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.39993RD ANGLE PROJECTION ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS 08581 D1DOME STANDARD INSTALLATION DETAILS ACCESSORIES NOT APPROVED FOR CONSTRUCTION 6/25/2021 JRB MC REL'D FOR FAB 8/31/2021 JWC JWC1 0 8581D1A2 CERTIFIED: APPROVED FOR CONSTRUCTION DETAIL B FLASHING & COUNTER FLASHING INSTALLATION RETAINER IS NOTCHED TO CLEAR EAVE ANGLE WASHERS, EVERY 4TH NOTCH IS SECURED BEHIND THE EAVE BOLT WASHER INNER COUNTER FLASHING OUTER COUNTER FLASHING #14 X 3/4" SS TEK SCREWS TYPICALLY SPACED AT 8" BUT USE AS REQ'D TO CLOSE ALL RETAINER & FLASHING GAPS PLACE 3 #14 x 1 1/4" TEK SCREWS EITHER SIDE OF SEAM IN SUPPORT BLOCK. PREDRILL 3/16"Ø HOLES TANK EAVE ANGLE BEND UNDER LAP TAB AND APPLY SEALANT AS REQ'D FOR WEATHER TIGHT SEAL AT ALL FLASHING JOINTS DOME FLASHING (TO BE INSTALLED CLOCKWISE TO ACHIEVE CORRECT LAP) COUNTER FLASHING RETAINER FIELD FORMED TO EAVE ANGLE O.D.FIELD CUT COUNTER FLASHING STRIP TO CORRECT LENGTH AND SEAL ANY GAPS BETWEEN COUNTER FLASHING JOINTS. USE SEALANT AND FASTEN WITH ALUMINUM RIVETS. #14 X 1 1/4" SS TEK SCREWS INNER COUNTER FLASHING LEAVE 1" GAP BETWEEN OUTER FLASHING EDGE AND TEK SCREW FOR MOVEMENT COUNTER FLASHING SPLICE:FIELD CUT COUNTER FLASHING STRIP TO CORRECT LENGTH AND SEAL ANY GAPS BETWEEN COUNTER FLASHING JOINTS. USE SEALANT AND FASTEN WITH ALUM RIVETS. USE #14 X 1 1/4" SS TEK SCREWS AS REQ'D #14 X 1 1/4" SS TEK SCREWS AT PIER FLASHING SHIMS BATTEN 1/4" X 3/4" TRILOBE SCREW W/ WASHER DOME FLASHING PIER HUB COVER FIELD APPLY SEALANT TO CREATE WEATHERPROOF SEAL BETWEEN FLASHING AND HUB COVER #14 X 1 1/4" SS TEK SCREWS AT SEAM LOCATIONS PIER SHIM (NEOPRENE) TIGHTEN AFTER ASSEMBLY NOTCHED FLASHING INNER COUNTER FLASHING OUTER COUNTER FLASHING USE SEALANT BETWEEN FLASHING & TANK SIDEWALL OUTER COUNTER FLASHING DETAIL A FLASHING INSTALLATION EAVE ANGLE AND TANK SIDEWALL #14 X 3/4" SS TEK SCREWS SPACED AROUND AT 8" OR AS REQ'D 10°APPROX 1" 1" APPROX. NYLON FLASHING SHIM STANDARD FLASHING TO EAVE CONNECTION1"REF.TANK GIRDER TOP & BTM HUBS AA SECTION A-A HUB COVER APPLY SEALANT BETWEEN HUB COVER AND HOIST RING BASE CENTER RING SAFETY TIE OFF POINT AT APEX 5000# MAX LOAD 2 1 4 3 FIELD DRILL FOR 3/4" BOLT 3 3 3 4 REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS JOB # THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.DWG SIZE: B DESCRIPTIONQTYPART NO.D/SITEM MAT'L. GR.EST. WT.PAINT DWG # TOLERANCES UNLESS OTHERWISE NOTED PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 130" - 240" LINEAR TOLERANCE: HOLE TO HOLE TOLERANCE: 240"+48" - 130"4" - 48"0 - 4" ANGULAR DEVIATION 1/32" 1/32" 1/16" 1/32" 5/32" 1/32" 1/8" 1/16" 3/16" 1/16" X = ±1.0° / X.X = ±0.5° TOTAL WT:PARENT: PROJ # CODE 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.39993RD ANGLE PROJECTION ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS ------CENTER RING GENERAL ARRANGEMENT FOR SAFTEY TIE OFF 8 SWITHCED TO NEW BORDER /8/2014 BDS -LP HARDWARE UPDATE 6/14/2016 MLH -LP HARDWARE UPDATE 6/28/2016 MLH -LP UPDATE BORDER /20/2020 PROG AUTO UPDATED BORDER 11/1/2020 BLD -WC6 5 4 3 2 --- CRGA05 CERTIFIED: APPROVED FOR CONSTRUCTION 1 B CRSB05 1 CENTER RING SUPPORT BLOCK 2 X 2 X 6.85 LG.6061 T6 3 -- 2 -3046T5 1 LARGE OPENING HOIST RING 1-4 PH SS 5 -- 3 -WSHLS050304 1 WASHER LOCK 3/4" 304SS 304SS --- 4 -BLTHS0501500304 1 BOLT 3/4" X 1 1/2" HEX HD 304SS 304SS --- 3" X 3" X 3/8" ALUM REINFORCING ANGLE FIELD CUT TO FIT BETWEEN DOME STRUTS WITH MINIMUM CLEARANCE (HEELS IN) DOME ACCESSORY APPROXIMATE 1" GAP BETWEEN DOME ACC. AND SUPT. ANGLE DETAIL B TYPICAL ACCESSORY PENETRATION REINFORCEMENT ANGLE DOME PANEL D D IF ACCESSORY CUT EDGE IS WITHIN 18" OF STRUT, SECOND SUPT. ANGLE NOT REQ'D. (3) 3/8" 304SS THIMBLE AND CLIP KIT, INSTALL CLIPS MAX OF 5" APART 3/8"Ø S.S. WIRE LOOP CABLE AND THIMBLE THROUGH CENTER SUPPORT RING FIELD APPLY SEALANT BETWEEN CENTER SUPPORT BLOCK AND HUB COVER EXTEND ROPE TO ACCESS LADDER OR PLATFORM AND CUT TO LENGTH, ATTACH TO PLATFORM 3/8" WIRE ROPE GRAB 304 SS INSTALL PER MFG. INSTRUCTIONS DETAIL A CENTER SAFETY GRAB CABLE INSTALLATION LEGEND 5 8 9 9 9 12 P12 PANEL # HUB # STRUT & BATTEN # BEAM DOME PANEL DOME PANEL SECTION D-D TYPICAL ALUM ANGLE SUPT INSTALLATION DRILL HOLES IN HINGE, ANGLE, AND BEAM AS NEEDED ALUM. HINGE 3" X 3" X 3/8" ALUM. REIN. ANGLE INSTALL ANGLE FLUSH WITH DOME PANEL 3/8" SS BOLTS, WASHERS & NUTS DETAIL G ALUMINUM DOME VENT WITH REINFORCEMENT ANGLE USE SEALANT DOME VENT ATTACH WITH 3/8" ALUM HUCK BOLTS 3" X 3" X 3/8" ANGLE (SEE DETAIL C) DOME PANEL DOME MANWAY DETAIL F DOME MANWAY WITH REINFORCEMENT ANGLE USE SEALANT ATTACH WITH 3/8" ALUM HUCK BOLTS 3" X 3" X 3/8" ANGLE (SEE DETAIL 'C') DOME PANEL TYPICAL PIER ATTACHMENT DETAILS TANK INT. EAVE ANGLE PIER ASSEMBLY PIER SHIM UTILIZE #SCWTEK140750188 FOR ATACHMENT OF #CFSPL006 ON BOTH SIDES OF PIER BASE (TO BE REMOVE AFTER DOME IS INSTALLED) UTILIZE 1/2" X 4" EXT. AND 1/2" X 3 3/4" INT. BOLTS, WASHERS, & NUTS FOR ATTACHMENT WIND GIRDER REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS JOB # THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.DWG SIZE: B DWG # TOLERANCES UNLESS OTHERWISE NOTED PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 130" - 240" LINEAR TOLERANCE: HOLE TO HOLE TOLERANCE: 240"+48" - 130"4" - 48"0 - 4" ANGULAR DEVIATION 1/32" 1/32" 1/16" 1/32" 5/32" 1/32" 1/8" 1/16" 3/16" 1/16" X = ±1.0° / X.X = ±0.5° TOTAL WT:PARENT: PROJ # 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.39993RD ANGLE PROJECTION ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS 08581 D1DOME STANDARD INSTALLATION DETAILS ACCESSORIES NOT APPROVED FOR CONSTRUCTION 6/25/2021 JRB MC REL'D FOR FAB 8/31/2021 JWC JWC1 0 8581D1A3 CERTIFIED: APPROVED FOR CONSTRUCTION RUBBER MASTER FLASH BOOT DOME PANEL FIELD CUT DETAIL K FLASHING BOOT DETAIL PIPING AND COMPONENTS NOT TO BE SUPPORTED BY DOME ORIENTATION NOTCH POINTS TO CENTER OF DOME 3" X 3" X 3/8" ANGLE PANEL NOZZLEATTACH WITH 1/2" X 1 1/4" SS304 BOLTS, WASHER, AND NUTS DETAIL J HILLSIDE NOZZLE DETAIL WITH REINFORCEMENT ANGLE (250# MAX LOAD) USE SEALANT PLAN VIEW SECTION A-A FOR USAGE WITH TIE OFF CABLE SECTION A-A REMOVE HOIST RING AND INSTALL ‘3/4" BOLT AND WASHER AT TOP SIDE AFTER INSTALLING COVER. A A PAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM -2ALUM 6061-T6SUPPORT BLOCK 2" SQ. X 5 7/8" LG.1SFTTIEOFF5B1 -0F593DBOLT 3/4" x 1 1/2" HEX HD 1BLTHS07501500F593D-2 -0A3043/4" LOCK WASHER SS1WSHLS0750304-3 -1F593DBOLT 3/4" x 2 1/2" HEX HD 1BLTHS07502500F593D-4 -0A304WASHER FLAT 3/4"1WSHFS0750304-5 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.3999 THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER. AFFILIATE GROUP ConnectionPERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 3/16" 1/16" 3 lbmass PARENT: X = “1.0ƒ / X.X = “0.5ƒ ANGULAR DEVIATION TOLERANCES UNLESS OTHERWISE NOTED HOLE TO HOLE TOLERANCE: LINEAR TOLERANCE: 1/32" 0 - 4" 1/32"1/16" 4" - 48" 1/32" 5/32" 48" - 130" 130" - 240"240"+ 1/16" 1/8" 1/32" ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS 3RD ANGLE PROJECTION REVISION DESCRIPTION PROJ #JOB # DWG # DRAWN BY SCALE: NTSCHECKED BYDATE TOTAL WT: 2 1 0 REV SFTTIEOFF5A BDWG SIZE: CERTIFIED: APPROVED FOR CONSTRUCTION RELEASED FOR FABRICATION JWC JRB4/16/2020 REV'D HARDWARE UPDATED HARDWARE 5/14/2020 JWC JRB 3/4/2021 BLD JRB TEMPORARY SAFETY TIE OFF ASSEMBLY SAFETY TIE OFF RING POINT AT APEX 5000# MAX LOAD 1 2 3 1 2 3 4 5 TOP HUB BTM HUB TOP HUB BTM HUB HUB COVER 1 1 1 12 2 PLAN VIEW DETAIL A SECTION B-B TYP (10) PLCS SECTION B ISOMETRIC VIEW CODEPAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM R-9 PIER ASSEMBLY108581D1PRASMB1 --0NEOPRENE1/4" NEOPRENE SHIM107970D1PRSHIMB2 A B B THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER. 91 lbmass PARENT:TOTAL WT: 0 REV 8581D1PRGA BDWG SIZE: 08581 D1 CERTIFIED: APPROVED FOR CONSTRUCTION RELEASED FOR FABRICATION JRB JWC8/31/2021 PIER LAYOUT 3609 North 16th St . Parsons, Kansas 67357620.423.3010 . fax: 620.423.3999 COLUMN TOLERANCES +0" / -1/8" “3/32" SQUARENESS TOLERANCE: LINEAR TOLERANCE: SCALE: NTS1/32" 1/8" JOB # 1/16" DWG # 1/16" 5/32" 240"+ 130" - 240" 3/16" 1/32" 1/16" 48" - 130" PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 4" - 48" 1/32" 1/32" 0 - 4" TOLERANCES UNLESS OTHERWISE NOTED ANGULAR DEVIATION LINEAR TOLERANCE: HOLE TO HOLE TOLERANCE: X = “1.0ƒ / X.X = “0.5ƒ PROJ # 270ƒ90ƒ 2 1 TANK INT. TANK EAVE/GIRDER 2 1 0ƒ 6'-8 3/4" 7'-1 11/16" 2 7/8" 8 7/8" 6'-6 1/2"2 3/4" 6'-11 1/2"8 3/4" 7 '-2 7 /8 " T Y P . C H O R D7'-0 3 /8 " T Y P . C H O R D 7 '-1 1 1 3 /1 6 " T Y P . C H O R D P24'-11 5/8" B.C. P24'-3 5/8" B.C. 8 '-2 1 /4 " T Y P . C H O R D R12'-6 1/16" R12'-1 9/16" REMOVED BOLTS CRASHING WITH PIER BASE MATCH, MARK AND DRILL. 0ƒ 180ƒ ISOMETRIC VIEW SIDE ASSEMBLY VIEWFRONT ASSEMBLY VIEW ITEM #1 TAPE DETAIL (OTHER COMPONENTS HIDDEN FOR CLARITY) ITEM #2 TAPE DETAIL (OTHER COMPONENTS HIDDEN FOR CLARITY) PAINTEST. WT.MAT'L. GR.DESCRIPTIONQTYPART NUMBERD/SITEM -56061-T6PIER BASE X 6 1/4" LG.18581D1PR1B1 -06061-T6PIER SHOE (DIE #18519) X 2 1/4in LG28581D1PR2B2 -06061-T6PIER LINK (DIE #18517) X 2 1/4in LG18581D1PR3-3 -26061-T6BEAM I-5 X 10 7/8" LG.18581D1PR4B4 -0NYLON 6/10.375 THK FLASHING SHIM1SHIMHDPE383BB5 -0-PTFE TAPE .020 THK X 3in X 2 1/4in LG18581D1PR2_PTFETAPE-6 -0-PTFE TAPE .020 THK X 1in X 2 1/4in LG28581D1PR2_PTFETAPE2-7 -0-PTFE TAPE .020 THK X 3" X 6 1/4" LG.1PTFETAP020315-8 -0-PTFE TAPE .020 THK X 3/4" X 6 1/4" LG.2PTFETAP0203415-9 -0F593DBOLT 3/4" x 2" HEX HD 1BLTHS07502000F593D-10 -0A316NUT 3/4" HEX HD 1NUTHS0750316-11 -0A304WASHER 3/4" LOCK1WSHLS0750304-12 -0A410#6-20 FLAT HEAD DRILLING SCREW X 3/4" LG2MC94195A120-13 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.3999 THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER. AFFILIATE GROUP ConnectionPERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 3/16" 1/16" 9 lbmass PARENT: X = “1.0ƒ / X.X = “0.5ƒ ANGULAR DEVIATION TOLERANCES UNLESS OTHERWISE NOTED HOLE TO HOLE TOLERANCE: LINEAR TOLERANCE: 1/32" 0 - 4" 1/32"1/16" 4" - 48" 1/32" 5/32" 48" - 130" 130" - 240"240"+ 1/16" 1/8" 1/32" ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS 3RD ANGLE PROJECTION REVISION DESCRIPTION PROJ #JOB # DWG # DRAWN BY SCALE: NTSCHECKED BYDATE TOTAL WT: 0 REV 8581D1PRASM BDWG SIZE: 08581 D1 CERTIFIED: APPROVED FOR CONSTRUCTION RELEASED FOR FABRICATION JRB JWC8/31/2021 PIER ASSEMBLY 22 22 2 2 1/4" REF 4 5 1 99 1 101112 8 3 77 6 3"1/4"1/4" 3 "3 1 4 13 5 13 24" SQ.(OPENING)S.S. HORIZONTAL COMPRESSION SPRING 24" SQ. (OPENING)32 5/8"1/8" THK EPDM GASKET COVER PLATE L 4 X 3 X 3/16 FRAME LIFTING HANDLE 2" 3/16" FLOOR PLATE MAT'L: ALUM. 3003 S.S. WATERTIGHT SLAMLOCK S.S. AUTOMATIC HOLD OPEN ARM EXTERIOR STAPLE FOR PADLOCK (FRAME LUG) EXTERIOR STAPLE FOR PADLOCK (COVER LUG) VINYL GRIP HANDLE ON HOLD OPEN ARM SLAMLOCK KEY HANDLE INT. DOME PANEL INT. DOME PANEL 2 7/8"8"8"8"2 7/8"29 3/4"1 5/16" DETAIL ITEM #2 8"8"8"25 3/4"1 5/16" DETAIL ITEM #3 7/16" DIA HOLES TYP. FASTEN WITH 3/8" HUCKBOLT TYPICAL 2 X 2 X 1/4 REINFORCEMENT ANGLE TYPICAL 3 SPCS @ 8" = 24" SQ.2"TYP7/8"7/8"APPLY SEALANT BETWEEN FRAME & PANEL 1 31 5/8" S.S. PIN HINGES 7/16" DIA HOLE TYP. 1 2 2 2 3 1 3 2 3 1 4 1/4"4 4 4 4 REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS JOB # THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.DWG SIZE: B DESCRIPTIONQTYPART NO.D/SITEM MAT'L. GR.EST. WT.PAINT DWG # TOLERANCES UNLESS OTHERWISE NOTED PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 130" - 240" LINEAR TOLERANCE: HOLE TO HOLE TOLERANCE: 240"+48" - 130"4" - 48"0 - 4" ANGULAR DEVIATION 1/32" 1/32" 1/16" 1/32" 5/32" 1/32" 1/8" 1/16" 3/16" 1/16" X = ±1.0° / X.X = ±0.5° TOTAL WT:PARENT: PROJ # CODE 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.39993RD ANGLE PROJECTION ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS ------24" SQUARE MANWAYTYPICAL ASSEMBLYFOR DOME 48 CHANGED TO 4" CURB HT.1/24/2013 BDS DM CHANGED TO 24" SQ. MANWAY 3/22/2016 BDS JLP CHANGED ANGLE HEEL DIM PER SHOP 9/30/2013 BEC BDS UPDATED LOCK STAPLES & REINFOR ANGLE 3/17/2016 MLH JLP UPDATE BORDER 9/21/2020 PROG AUTO5 4 3 2 1 MWSQ30.dwg MWSQ24 CERTIFIED: APPROVED FOR CONSTRUCTION 1 -DMHALSRRI2424 1 24 IN DOME SQ. MANWAY ALUM/S.S.38 -- 2 -MWSQ24RA1 2 ANGLE 2 X 2 X 1/4 X 29 3/4" LG.6061-T6 3 -- 3 -MWSQ24RA2 2 ANGLE 2 X 2 X 1/4 X 25 3/4" LG.6061-T6 2 -- 2 1 3 4 1 20" MANWAY VENT NECK DOUBLE NUT (1) SIDE FOR HINGE BIRD SCREEN GASKET 6 5 DOME PANEL 1 2 2 2 REV CHECKED BYDRAWN BYDATEREVISION DESCRIPTION SCALE: NTS JOB # THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL PROPERTY OF TANK MANUFACTURER AND/OR ITS AFFILIATES. ANY OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS STRICTLY PROHIBITED, WITHOUT THE EXPRESSED WRITTEN CONSENT OF TANK MANUFACTURER.DWG SIZE: B DESCRIPTIONQTYPART NO.D/SITEM MAT'L. GR.EST. WT.PAINT DWG # TOLERANCES UNLESS OTHERWISE NOTED PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES 130" - 240" LINEAR TOLERANCE: HOLE TO HOLE TOLERANCE: 240"+48" - 130"4" - 48"0 - 4" ANGULAR DEVIATION 1/32" 1/32" 1/16" 1/32" 5/32" 1/32" 1/8" 1/16" 3/16" 1/16" X = ±1.0° / X.X = ±0.5° TOTAL WT:PARENT: PROJ # CODE 3609 North 16th St . Parsons, Kansas 67357 620.423.3010 . fax: 620.423.39993RD ANGLE PROJECTION ***DO NOT SCALE*** DRAWING IN INCHES ANSI/ASME Y14.1 STANDARDS ------VENT ASSEMBLY 20"Ø ALUM WITH BIRD SCREEN 35 SWITCHED TO NEW BORDER 9/9/2014 BDS JLP REVISED LEADER TEXT 8/25/2015 JLP BDS HARDWARE UPDATE 6/14/2016 MLH JLP UPDATE BORDER 9/21/2020 PROG AUTO3 2 1 0 --- VAB20BAL CERTIFIED: APPROVED FOR CONSTRUCTION 1 B VCA20B 1 20" ALUM. BIRD VENT CAP ASSEMBLY -24 -- 2 -BLTHS05002000304 2 1/2" X 2" HEX HD BOLT 304SS ---- 3 -NUTHS0500316 4 1/2" HEX NUT ---- 4 -WSHFS0500304 2 1/2" FLAT WASHER 304SS ---- 5 B GSKTE20PRV 1 20" GASKET EPDM -1 -- 6 B VNB20AL 1 20" VENT NECK ALUM -10 --