Loading...
HomeMy WebLinkAboutPLANS REDLINED REVISIONS - 20-00735 -Teton River Flats Community Housing - 4Plex - A1Author Name Author Email Author Phone No.: Ted Dye tedd@rexburg.org 208-372-2172 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Teton River Flats Community Housing - 4Plex - A1Address : 280 Lorene St Units 1101, 1102, 1201, 1202Application Type : Document Filename : Teton River Flats.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments SD1.1 - SITE PLAN- LAYOUT Free text Ted Dye : Building Open 18 Insert text here SD1.1 - SITE PLAN- LAYOUT Callout Ted Dye : Building Open 18 If building are closer than 10' between both buildings will haveto have a 1hr fire rating. SD1.1 - SITE PLAN- LAYOUT Free text Cody Jones : Building Open 18 Type A and Type B units need to comply with 2015 IBC A1.1 - MAIN &UPPER FLOORPLANS Free text Ted Dye : Building Open 19 Entrance doors need to be a 20 min. door with self closinghinges. A1.1 - MAIN &UPPER FLOORPLANS Free text Cody Jones : Building Open 19 Emergency Escape and Rescue openings shall have aminimum net clear opening of 5.7 square feet. A1.2 - ROOFPLAN Free text Cody Jones : Building Open 20 36" frost depth for footings. A2.1 - EXTERIORELEVATIONS Callout Cody Jones : Building Open 21 The net free ventilating area shall be not less than 1/150 of thearea of the space ventilated. A3.1 Free text Cody Jones : Building Open 22 Sprinkler system # 20-00735New Multi-Family Residence Report Date: 15-10-2020 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments A3.1 Free text Cody Jones : Building Open 22 to comply with 903.2 Report Date: 15-10-2020 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) Insert text here If building are closer than 10' between both buildings will have to have a 1hr fire rating. T y p e A a n d T y p e B u n i t s n e e d t o c o m p l y w i t h 2 0 1 5 I B C Entra n c e d o o r s n e e d t o b e a 20 mi n . d o o r w i t h s e l f c l o s i n g hinge s . Emergency Escape and Rescue openings shall have a minimum net clear opening of 5.7 square feet. 0.9 5 f t 20.05 ft 19.99 ft 1 9 . 9 5 f t 36" f r o s t d e p t h f o r f o o t i n g s . The net free venti l a t i n g area shall be not l e s s than 1/150 of the a r e a o f the space ventilat e d . Sprinkler system to comply with 903.2